Papers / Semenov et al. 2025

Semenov et al. 2025 · Cell Reports Physical Science

Excitation and polarization of isolated neurons by high-frequency sine waves for temporal interference stimulation

Iurii Semenov, Vitalii Kim, Giedrė Šilkūnienė, Andrei G. Pakhomov

Outcomes of 102 claims

  • 14 reproduced
  • 11 partially reproduced
  • 26 not reproduced
  • 51 blocked

Summary, DANDI:001048: Most of this paper's main findings could not be fully tested in this data. The dandiset itself holds none of the paper's data, so the checks ran on the nine dandisets the paper lists, using an assumed soma region. Reproduced: pure sine waves fire more action potentials than modulated ones, and firing locks to the beats of modulated waves. Partly reproduced: AP peak height held but duration did not, and modulated thresholds came out higher with only one of three tests significant. Not reproduced: the excitation block at the highest fields. Blocked: the 20 kHz versus 2 kHz threshold ratio, which needs voltage calibration that is not deposited, and the low-conductivity thresholds, whose sessions are missing. The Figure 4 to 6 membrane-charging findings were also blocked, because the strobe files hold no ROIs or cell identities.

Summary, DANDI:001271: Two main findings held up, several did not, and the tetrodotoxin results could not be tested. Pure sine waves evoked more spikes than 20-Hz modulated waves, and modulated firing locked to the beats, both on an assumed reading of the criterion. Firing rates stayed well below the reported 60 to 90 Hz, and 20-kHz thresholds were not about twice the 2-kHz ones. Sustained depolarization was not detected, though the measure may miss plateaus this small. The tetrodotoxin effects stayed untested because the paper does not say how the soma was outlined on the deposited crops, the low-conductivity recordings are absent, and the pulse-kinetics findings were not attempted.

Summary, DANDI:001272: Some of the paper's main findings held in this data, others did not, and two could not be tested. Unmodulated waves evoked more spikes than 20-Hz modulated waves, firing mostly locked to the beats, and tetrodotoxin abolished spikes. Excitation of every neuron with delayed spikes, the doubled 20-kHz threshold, higher thresholds for modulated waves and the membrane charging times did not reproduce; the amplitude calibration and the debris ROI are not deposited. The low-conductivity finding has no deposited data and the sine-versus-pulse finding was not attempted. The control holds 3 neurons, against 8 in the paper.

Summary, DANDI:001273: Of the paper's main findings on membrane charging by 2-us pulses, two held here, the pooled time constants did not, and the shape and alignment effects could not be tested without shape labels in the dataset. Polarization at the electrode-facing poles held (13 of 14 experiments), as did equal charging at both poles, though that test has little power. Pooled discharging times came out longer than reported, and the paper's ROIs and fit settings are not given. Sustained firing partly held and the Di-8-ANEPPS control did not, under a 5% level set for another dye. The sine wave excitation and threshold findings are in other dandisets and were not tested for lack of time.

Summary, DANDI:001274: Most of the paper's main findings on sine wave excitation of neurons did not hold up in this data, and the polarization findings could not be tested. Unmodulated waves evoked more action potentials than modulated ones, and modulated thresholds were higher, though only in part. The delayed onset of firing, the firing rate ceiling, the excitation block and the twofold higher 20-kHz thresholds missed, and the 2-kHz threshold was 75.6 against 57.7 V/cm. The generator calibration behind the field values is not deposited, which may explain the threshold misses. The polarization and sodium gluconate findings could not be tested because the dataset has no ROIs, cell identifiers or gluconate sessions.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to an attempt

Attempts 5

5 current

Every attempt on the paper, each with the datasets it used and their versions. An attempt on a dataset replaces the one before it on that dataset; the paper’s page shows the current ones.

  1. Attempt 012026-11-01current
    DANDI:001048 version 0.250701.1624
    20 claims · 10 findings about the data · protocol pilot-13
  2. Attempt 022026-11-01current
    DANDI:001271 version 0.250805.1352
    20 claims · 11 findings about the data · protocol pilot-13
  3. Attempt 032026-11-01current
    DANDI:001272 version 0.250805.1358
    19 claims · 11 findings about the data · protocol pilot-13
  4. Attempt 042026-11-01current
    DANDI:001273 version 0.250805.1356
    17 claims · 10 findings about the data · protocol pilot-13
  5. Attempt 052026-11-01current
    DANDI:001274 version 0.250805.1401
    26 claims · 11 findings about the data · protocol pilot-13

Claims

Attempt semenov-2025-01, on DANDI:001048 version 0.250701.1624

Reproducing Semenov et al. (2025) from the DANDI datasets it names 15 Open in Colab

Reproduced3

  • Reproduced

    All thresholds to elicit 5 APs were higher than those for 1 AP.

    Under the crop ROI the mean 5-AP threshold is above the mean 1-AP threshold for all four stimuli in all four…

    Results, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2Drests on an assumptiondata in DANDI:001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig2d-5ap-above-1ap
    From the paper

    All thresholds to elicit 5 APs were expectedly higher than those for 1 AP

    Result

    Under the crop ROI the mean 5-AP threshold is above the mean 1-AP threshold for all four stimuli in all four F0 and O3 readings (F0 a, O3 a - 5.00 against 4.22 V pure 2 kHz, 6.15 against 5.38 modulated 2 kHz, 13.55 against 9.85 pure 20 kHz, 17.20 against 14.00 modulated 20 kHz, with 2 of 3 modulated 20-kHz neurons reaching 5 APs). Under the Otsu ROIs at most 1 neuron reaches 5 APs with modulated waves, so those comparisons cannot be made, and under ROI b with O3 a the 5-AP mean is below the 1-AP mean for pure 2 kHz (4.65 against 4.85 V, over 4 and 22 neurons) and pure 20 kHz (12.00 against 12.33 V, over 1 and 9). The means are over different numbers of neurons; within a neuron the 5-AP threshold cannot be below the 1-AP one.

    Deviations from the paper’s method
    • The crop ROI is assumed, as for ap-selection; the Otsu readings give a different outcome.
  • Reproduced

    With 20-Hz modulation, firing above threshold locked to the beats, one AP near the peak of each of the five beats and at most two per beat (ten in all), and modulated sine waves triggered no sustained firing or sustained depolarization.

    No modulated session has more than 10 APs (at most 8, of 84).

    Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 1; Figures 2A and 2Bverifier disagreed at firstrests on an assumptionquestion to the readerdata in DANDI:001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig2-modulated-locks-to-beats
    From the paper

    single APs emerged near the peak of each beat, so the firing rate equaled the modulation rate ... At the highest field strengths, each beat could elicit a pair of APs, so the maximum number of APs evoked by five beats was limited to ten. Unlike pure sine waves, modulated stimuli did not trigger sustained firing or sustained depolarization

    Result

    No modulated session has more than 10 APs (at most 8, of 84). In the 16 sessions with at least 5 APs (ROI c), 96.4 % of APs fall within 12.5 ms of beat peaks 25 ms into each beat (envelope reading a) and 3.6 % under reading b; the APs lock to 26.6 ms of the 50-ms beat (vector strength 0.735, Rayleigh p = 2.0e-20), at both carriers. Under O4 b no session shows sustained depolarization; under O4 a one does under the crop ROI (001032/2_1 at 11 V, 3 APs, none in its last 100 ms, a session cut at 291 ms), none under the Otsu ROIs. Its last-100-ms mean dF is 5.96 %, above the O4 a level (4.72 %) and 0.14 % below the O4 b level (6.10 %, half its median AP height of 12.20 %), so the outcome rests on O4 b by a small margin in one session. It is the only modulated session with a last-100-ms mean dF above 5 %. Under the Otsu ROIs at most one session reaches 5 APs, so the locking is shown under the crop ROI.

    Deviations from the paper’s method
    • The files hold no stimulus waveform. The envelope is assumed to start at minimal amplitude (reading a), as the paper's Methods say of the modulated strobe waves ("the first and the last sine wave cycles (when its amplitude was minimal)"); under reading b the APs would sit at the envelope's minima, where the field is near zero. Reading b fails.
    • The O4 level is assumed to be half the neuron's median AP height (reading b), as the paper describes the sustained depolarization as APs that "merge into sustained depolarization" (Summary), a level of the order of the APs themselves; under reading a (5 SD of the pre-onset noise) one of 84 sessions, cut short by the end of its recording, passes it. The choice was made after the first run showed that session. It is the assumed reading wherever O4 decides, and it decides only this claim - fig1-excitation-block, fig3c-sustained-firing-2s and figs2-ttx-blocks-depolarization give the same outcome under both levels.
    • The crop ROI is assumed, as for ap-selection.
  • Reproduced

    In the same neuron, the threshold was typically lower for unmodulated sine waves, and at the same field strength pure sine waves triggered more APs than modulated ones.

    Under the crop ROI pure waves gave more APs than modulated ones at the same carrier and voltage in 44 of 52…

    Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 2; Figures 2A to 2Crests on an assumptiondata in DANDI:001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig2c-pure-more-aps
    From the paper

    When modulated and unmodulated sine waves of the same carrier frequency were tested in the same cell, the threshold was typically lower for unmodulated signals ( Figures 2A - 2C ). At the same field strengths, pure sine waves triggered a larger number of APs

    Result

    Under the crop ROI pure waves gave more APs than modulated ones at the same carrier and voltage in 44 of 52 pairs against 2 (mean difference 3.35 APs, paired p = 1.2e-08), and the pure 1-AP threshold was lower in 14 of 15 neurons (higher in none). Both parts hold in 11 of the 12 readings; under ROI b with F0 b and O3 b the counts favour pure waves (9 pairs against 6) but of the 3 neurons with both thresholds the pure one is lower in none and higher in 1.

    Deviations from the paper’s method
    • The crop ROI is assumed, as for ap-selection; one Otsu reading gives a different outcome.

Partially reproduced6

  • Partially reproduced

    Neurons were selected for APs peaking above 5% dF and lasting about 10 ms; typical APs were 11.3% dF high and 8 ms long, excluding the afterhyperpolarization (mean of 22).

    Over 39 neurons of 001032, 001033 and 001035 (ROI c, F0 a, O3 a, every AP, width at half height), the mean AP…

    Methods, Recording of the optical APs and data analysesrests on an assumptiondata in DANDI:001030 (0.240520.1924) and 001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titles; the paper does not say which 22 neurons these areap-selection
    From the paper

    we selected neurons whose APs peaked at a more than 5% Δ F and lasted about 10 ms (typical values ... 11.3% ± 0.9% Δ F and 8 ± 0.7 ms duration, excluding afterhyperpolarization; mean ± SEM, n = 22)

    Result

    Over 39 neurons of 001032, 001033 and 001035 (ROI c, F0 a, O3 a, every AP, width at half height), the mean AP peak is 10.53 +- 0.38 % dF and the duration 3.70 +- 0.18 ms. Under the crop ROI the peak is within 11.3 +- 0.9 in 12 of 16 readings (10.27 to 11.46 %); the duration is in range under none (half width 3.11 to 3.71 ms, rise to return 17.31 to 24.14 ms). Under ROI a the peak is within the SEM in all 16 readings (11.01 to 11.56 %) and the duration in none. Under ROI b the peak is 12.68 to 14.67 %, outside it, and three readings give a rise-to-return duration in range (7.32 to 8.57 ms). The peak holds under the crop ROI in 12 of 16 readings (it fails in the four that measure every AP with O3 b, 10.27 to 10.41 %) and under ROI a in all 16; the duration holds under no reading in which the peak holds. The paper does not say which 22 neurons were measured; 39 are deposited.

    Deviations from the paper’s method
    • The soma ROI is the 16 x 16 pixel crop the depositors cut around the soma (reading c), adopted as the paper's "emission intensity over the entire cell soma" (Methods, Recording of the optical APs) because the crop is the dataset's own soma region and the claims file says ROIs are taken from the dataset when it holds them (O1). The claims file's Otsu readings (a, b) give masks of a median 35 and 10 pixels, some of 1 to 3, with about twice the noise; they are shown. Where the ROI readings disagree the claims file's header would block the claim; under protocol step 1.6 the crop is adopted as an assumption.
    • APs are detected by the claims file's rule (O3), with the width at half height required to be 2 to 20 ms both at half the peak's dF and at half its prominence (an assumption; each measure alone fails on these traces, and both are shown as variants). The paper identified APs by eye.
  • Partially reproduced

    Unmodulated 250-ms sine waves at 2 and 20 kHz excited every neuron tested; near threshold isolated APs came 100 to 200 ms after onset, and stronger fields shortened the delay and evoked sustained firing whose maximum rate rose linearly to a ceiling of 60 to 90 Hz.

    Under the crop ROI unmodulated waves excited 27 of 28 neurons at 2 kHz (96.4 %) and 15 of 17 at 20 kHz (88.2 %…

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 2; Figures 1A to 1C and insetverifier disagreed at firstrests on an assumptionquestion to the readerdata in DANDI:001030 (0.240520.1924) and 001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig1-pure-sine-excites-all
    From the paper

    Pure sine waves at 2 and even 20 kHz excited 100% of neurons ... at near-threshold electric field strengths, isolated APs emerged with a delay of 100–200 ms after the sine wave onset ... Increasing the field strength reduced this delay and evoked sustained firing ... The maximum firing rate increased linearly until reaching a ceiling of 60–90 Hz

    Result

    Under the crop ROI unmodulated waves excited 27 of 28 neurons at 2 kHz (96.4 %) and 15 of 17 at 20 kHz (88.2 % with O3 a, given as measured; 94.1 % with O3 b), and the first-AP latency fell with voltage in 34 of 37 neuron-frequencies (Spearman rho below 0). Under every reading the median latency at threshold is 59.8 to 88.4 ms, below 90 to 220 ms, and the median highest maximum firing rate is 22.6 to 42.3 Hz, with 9.1 to 31.0 % of neurons in 54 to 99 Hz, so neither ceiling reading holds. Per frequency (ROI c) the median latency at threshold is 59 ms at 2 kHz and 124 ms at 20 kHz. Two of the 42 latencies at threshold are under 5 ms (median 63.9 ms without them); such early APs are not onset artefacts, since the same stimulus under TTX gives no transient above 5 % in the first 10 ms in any of 71 sessions (145 of 211 without TTX). Under the Otsu ROIs 39.3 to 85.7 % of neurons are excited at 2 kHz. Below each neuron's highest rate the rate rises with voltage (slope positive in 23 of 23 neurons, median 12.3 Hz per V; not deciding).

    Deviations from the paper’s method
    • Fields are the labelled generator voltages (see fig2d-modulated-thresholds-higher); the claim uses only their order.
    • The excitation part depends on the ROI (90 % or more under the crop ROI with O3 b only); the crop ROI is assumed, as for ap-selection. The latency and ceiling parts fail under every reading.
  • Partially reproduced

    Thresholds for sine waves modulated at 20 Hz were significantly higher than for pure sine waves at the same carrier frequency for 5 APs at 2 kHz and for 1 and 5 APs at 20 kHz, so modulation did not lower excitation thresholds; the 2-kHz unmodulated AP threshold was 57.7 ± 3.6 V/cm.

    Under the crop ROI modulated thresholds are higher than unmodulated ones in every comparison, but only one of…

    Results, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2D and legend; Results, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, last paragraphrests on an assumptiondata in DANDI:001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig2d-modulated-thresholds-higher
    From the paper

    thresholds for modulated sine waves, which emulate the TI stimulus at the target, were significantly higher than those for pure sine waves at the same frequency (for 2 kHz, 5 APs ... p = 0.0079; for 20 kHz, 1 and 5 APs, respectively ... p = 0.0142 and p = 0.0037). Thus, modulated sine waves were equally or less efficient than pure ones at eliciting APs

    Reported statistics
    • modulated against unmodulated, 2 kHz, 5 APs: two-tailed unpaired t test, p = 0.0079
    • modulated against unmodulated, 20 kHz, 1 AP: two-tailed unpaired t test, p = 0.0142
    • modulated against unmodulated, 20 kHz, 5 APs: two-tailed unpaired t test, p = 0.0037
    Result

    Under the crop ROI modulated thresholds are higher than unmodulated ones in every comparison, but only one of the paper's three significant differences is significant - 20 kHz with 1 AP, p = 0.034 under O3 a (0.10 under O3 b), with 3 modulated neurons; 20 kHz with 5 APs p = 0.13 (2 neurons), 2 kHz with 5 APs p = 0.12 (paper 0.0079). 2 kHz with 1 AP does not differ the other way (p = 0.056, modulated higher). Paired, the 2-kHz 1-AP threshold is higher with modulation in 11 of 12 neurons (p = 7.9e-05). With O3 b none of the three tests reaches p < 0.05 even under the crop ROI, the direction still holding in all four comparisons. Under the Otsu ROIs no test reaches p < 0.05, and under ROI b with O3 a the 20-kHz 1-AP mean is lower with modulation (12.00 against 12.33 V, p = 0.86). With the first round's detector the 20-kHz tests give p = 0.021 and 0.031 and the 2-kHz 5-AP test 0.09. The mean unmodulated 2-kHz threshold is 4.22 V peak to peak, 76.0 V/cm (1 AP, given as measured) or 90.1 V/cm (5 APs) with 36 V/cm per volt of amplitude, and twice that per volt peak to peak; none is within 57.7 +- 3.6, but the files say the labels are not the delivered amplitude and the calibration is not deposited, so this part cannot be judged. The direction holds; the significance holds in one of three tests.

    Deviations from the paper’s method
    • The conversion of labelled volts to V/cm is not settled by the files ("1V translates into 36 V/cm" with the voltage labelled peak to peak); both readings are run. The files also say the labels are not the delivered amplitude.
    • The crop ROI is assumed, as for ap-selection. The one significant test needs the crop ROI with O3 a (p = 0.034; 0.10 with O3 b); under the Otsu ROIs no test is significant and one direction reverses.
  • Partially reproduced

    In the low-conductivity solution, a 2-s unmodulated 2-kHz sine wave ramped up over 250 ms evoked firing for its whole duration; the firing rate rose with field until replaced by a firing block with sustained depolarization, which developed before the end of the ramp.

    In all four neurons of 001030 (ROI c, bleaching-corrected) some voltage gives APs in the last 250 ms of the…

    Results, Decreased extracellular conductivity lowers excitation thresholds, paragraph 4; Figure 3Cverifier disagreed at firstdata in DANDI:001030 (0.240520.1924), assigned from its titlefig3c-sustained-firing-2s
    From the paper

    we observed sustained firing for the entire duration of the sine wave ( Figure 3C ). The rate of firing increased with the electric field strength until it was replaced by a firing block and sustained depolarization. The block had already developed before the end of the 250-ms ramp-up period

    Result

    In all four neurons of 001030 (ROI c, bleaching-corrected) some voltage gives APs in the last 250 ms of the 2-s wave and the AP count rises with voltage up to a point. No neuron under any reading shows the block at the highest voltage (no AP after 275 ms with a raised dF). c7 at 2.3 V comes close - 7 APs in the ramp and one after 275 ms (at 1,964 ms, 8.0 % high, prominence 4.4 %) on a mean dF of 6.72 %; the first round's detector counted 11 there (prominences 2.7 to 6.4 %). c8 at 2.0 V keeps 6 APs after 275 ms (prominence 4.1 to 7.2 %) on 3.63 %. At the top voltage the count falls (c7 88 to 8, c8 46 to 8). Two c5 sessions end at 1,914 ms.

    Deviations from the paper’s method
    • Bleaching is corrected by subtracting a trace without APs (Methods, F2). The only such trace in 001030 is c7 at 1.0 V, so it is subtracted from every session; uncorrected traces are a variant.
    • Figure 3C shows one neuron; the criterion is taken to hold when one neuron meets all three parts.
  • Partially reproduced

    With Di-8-ANEPPS in place of FluoVolt, in eight neurons, 2-kHz sine waves near threshold elicited one or a few delayed APs, and stronger fields shortened the delay and induced sustained firing ending in sustained depolarization, as with FluoVolt.

    001272 holds 3 Di-8-ANEPPS neurons, not 8.

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 2; Figure S1verifier disagreed at firstrests on an assumptiondata in DANDI:001272 (0.250805.1358), assigned from its titlefigs1-di8-same-as-fluovolt
    From the paper

    Experiments were performed on eight neurons using different electric field strengths tested in a random sequence ... Stimulation near the threshold elicited one or a few delayed APs. Increasing the electric field strength reduced the delay and induced sustained firing that culminated in sustained depolarization. Overall, stimulation effects were not different from those observed with FluoVolt dye

    Result

    001272 holds 3 Di-8-ANEPPS neurons, not 8. The inverted APs are small (median 4.2 % dF, 13 % above 5 %), so O3 b alone applies, as the claims file says. Under the crop ROI with O3 b, most of the 3 neurons show one to three APs at their lowest voltage with APs (3 with F0 a, 2 with F0 b), a latency that falls with voltage (2 of 3, with rho -0.03 and -0.69; -0.12 and -0.76 with F0 b) and sustained firing or depolarization above it (3 of 3). Under the Otsu ROIs with O3 b the latency falls in at most 1 of 3 and one or two neurons have no AP. The behaviour holds in the deposited neurons under the crop ROI; the count of eight does not.

    Deviations from the paper’s method
    • Only 3 of the paper's 8 neurons are deposited.
    • The crop ROI is assumed, as for ap-selection; the Otsu readings give a different outcome.
  • Partially reproduced

    1 uM tetrodotoxin abolished both the APs and the sustained depolarization evoked by intense unmodulated 2-kHz sine waves, while the vehicle did not.

    Under the crop ROI all 6 TTX neurons had APs before TTX at the voltages also tested after it and none…

    Results, Tetrodotoxin blocks sustained depolarization, paragraph 1; Figure S2 legendrests on an assumptionquestion to the readerdata in DANDI:001271 (0.250805.1352), assigned from its titlefigs2-ttx-blocks-depolarization
    From the paper

    the inhibition of sodium channels with 1 μM tetrodotoxin not only abolished the APs but also fully blocked the sustained depolarization

    Result

    Under the crop ROI all 6 TTX neurons had APs before TTX at the voltages also tested after it and none responded after (no AP, no sustained depolarization); after TTX the mean dF in the last 100 ms stays at or below 0.42 %. In 5 of 6 (3 or 4 with F0 b) every session before TTX responded; in 001271/14_20240731 one of 8 did not. Sustained depolarization before TTX occurred only in that neuron (2 sessions; median last-100-ms dF 5.08 and 5.18 % at 4.5 and 5 V before, -0.46 and -0.66 % after), so its abolition rests on one neuron. 11 of 13 vehicle neurons responded at every common voltage after the pause, all 13 at some. The two that did not at every voltage are 001271/4_20240730 (2 of 3), whose longest pause is 73 s, so no change of solution can be placed, and 001271/5_20240801 (5 of 7). The split pause is about 300 s in most vehicle neurons, 167 s in 001271/13_20240731, 73 s in 001271/4_20240730 and 35 s in 001271/17_20240801 (no common voltage). Under the Otsu ROIs at most 1 of 6 TTX neurons responds at every voltage before TTX.

    Deviations from the paper’s method
    • Vehicle neurons carry no mark of when the vehicle was applied; the split is assumed at the longest pause between sessions (about 300 s in most, the Figure S2 legend's "about 5 min").
    • The crop ROI is assumed, as for ap-selection.

Not reproduced1

  • Not reproduced

    At the highest fields, unmodulated sine waves merged APs into low-amplitude oscillations on a continuous depolarization, which could flatten and leave the membrane depolarized for the rest of the stimulus (an excitation block), and this depolarization reversed immediately when the stimulus stopped.

    Of the 12 to 14 neuron-frequencies tested above the voltage of their highest firing rate (ROI c), none shows…

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 2; Results, Tetrodotoxin blocks sustained depolarization, paragraph 1; Figure 1data in DANDI:001030 (0.240520.1924) and 001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig1-excitation-block
    From the paper

    At the highest field strengths, multiple APs coalesced into low-amplitude oscillations on top of a continuous depolarization. These oscillations could flatten after several cycles, leaving the membrane depolarized for the rest of the sine wave ... The sustained depolarization induced by intense unmodulated sine waves ( Figures 1 and 3 ) was immediately reversible upon stimulus cessation

    Result

    Of the 12 to 14 neuron-frequencies tested above the voltage of their highest firing rate (ROI c), none shows sustained depolarization (O4, either level) at its highest voltage; under ROI a 2 of 12 to 15 do (one of them falling below the O4 level in the 50 ms after the stimulus), and under ROI b 1 of 4 to 13 (O4 b only). Most neurons still fire in the last 100 ms at their highest voltage. Two sessions at any voltage meet O4 a under the crop ROI (001032/12_1 at 15 V, with no AP and 9.82 % mean dF in the last 100 ms, and 001033/3_2 at 9 V), and the mean dF in the last 100 ms rises with voltage (rho median 0.93, positive in 42 of 45), so a depolarization builds up, but the block is rare. 001032/12_1 at 15 V stays depolarized after the stimulus (7.87 % over 50 ms), against the claim's immediate reversal. 38 sessions of 900 frames end at 291 ms, before the stimulus. The outcome is the same under the first round's detector and with the width at half the dF only (0 of 11 to 22).

    Deviations from the paper’s method
    • Traces are not corrected for bleaching, as the claims file says (F2, only the 2-s traces were); the mean dF in the 50 ms after the stimulus is mostly below 0, so the late dF is biased down by up to a few percent, against finding the block.

Blocked5

  • Blocked

    All excitation thresholds at 20 kHz were about 2-fold higher than at 2 kHz.

    The claim is a ratio of fields in V/cm at 20 and 2 kHz.

    Metadata insufficientResults, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2Dverifier disagreed at firstdata in DANDI:001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig1-20khz-needs-twice-the-field
    From the paper

    All thresholds at 20 kHz were about 2-fold higher than at 2 kHz ( p < 0.0001, two-tailed unpaired t test)

    Reported statistics
    • 20 kHz against 2 kHz thresholds: two-tailed unpaired t test, p < 10⁻⁴
    Result

    The claim is a ratio of fields in V/cm at 20 and 2 kHz. The files give labelled generator voltages and say the delivered amplitude differs from the label by frequency-dependent calibration factors "reported separately", which are in none of the dandisets, so the ratio cannot be formed. Not deciding - in labelled volts the 20-kHz thresholds are higher in every reading (pooled p 2.5e-06 to 2.2e-24; under the crop ROI the unmodulated tests reach p 5.1e-10 to 8.2e-10 for 1 AP and 1.9e-12 to 4.1e-12 for 5 APs), and the ratios of the means are 2.33 to 2.80 under the crop ROI (2.04 to 3.52 over all readings), outside 2 +- 0.2. Within the 11 neurons tested at both frequencies the median ratio is 3.36. The 20-kHz modulated group has 3 neurons. Recorded as partially reproduced in the first round; blocked after the verifier's round 1.

  • Blocked

    Excitation by pure sine waves was not caused by heating; the adiabatic temperature rise was 2.5 C after 250 ms at 63 V/cm in NaCl, at most 1.24 C for the same stimulus in the low-conductivity solution, where it evoked sustained firing, and 4.1 C at 81 V/cm in NaCl.

    With water's heat capacity (4.18 J per cm3 per K), 63 V/cm in NaCl gives 3.89 C (peak field) or 1.95 C (RMS)…

    Methods underspecifiedResults, Decreased extracellular conductivity lowers excitation thresholds, paragraph 3; Figure 3Adata in DANDI:001030 (0.240520.1924) or 001032 to 001035 (0.240527.1431 or 0.240527.1432) for the Figure 3A neuron, assigned from their titles; the temperatures are calculated, not measuredfig3-not-heating
    From the paper

    the maximum theoretical temperature rise (assuming no heat dissipation 43 ) was 2.5°C after 250 ms of near-threshold stimulation at 2 kHz, 63 V/cm, in the NaCl-based solution ( Figure 3A ). The same stimulation in the low-conductance solution elicited sustained neuron firing while the temperature rise would not exceed 1.24°C ... 81 V/cm in the NaCl solution, which would heat by 4.1°C in the adiabatic conditions. These observations prove that excitation by pure sine waves was not caused by heating

    Result

    With water's heat capacity (4.18 J per cm3 per K), 63 V/cm in NaCl gives 3.89 C (peak field) or 1.95 C (RMS), neither 2.5 C; 63 V/cm in NaGlu 1.99 or 1.00 C (paper 1.24); 81 V/cm in NaCl 6.44 or 3.22 C (paper 4.1). Both ratios follow the formula (81/63 squared 1.653 against the paper's 1.640, 0.8 % apart; 8.4/16.4 0.512 against 0.496, 3.3 % apart), so by the criterion the claim is blocked. 2.5 C needs a heat capacity of 6.51 J per cm3 per K with the peak field or 3.25 with the RMS field. The Figure 3A neuron is not deposited. Question for the authors - which field (peak or RMS) and heat capacity give 2.5 C.

  • Blocked

    Membrane charging by 2-us pulses is fast; pooled over 19 experiments, charging and discharging time constants averaged 0.7 and 0.91 us at the cathodic pole and 0.65 and 0.8 us at the anodic pole, so the membrane charges fully within each sine wave cycle up to 100 to 200 kHz.

    The claim is a mean over the paper's 19 experiments in hand-drawn ROIs.

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4D and 4Everifier disagreed at firstdata in DANDI:001273 (0.250805.1356), assigned from its titlefig4-pooled-time-constants
    From the paper

    The time constants pooled together for all cells averaged 0.7 ± 0.08 (charging) and 0.91 ± 0.08 (discharging) μs for the cathodic cell pole and 0.65 ± 0.05 and 0.8 ± 0.07 μs for the anodic pole, respectively (mean ± SEM, n = 19)

    Result

    The claim is a mean over the paper's 19 experiments in hand-drawn ROIs. 001273 holds no ROIs and does not say which of its 22 groups are the 19 experiments; its groups were run at 40 to 130 V, whose session descriptions give measured amplitudes of 25 to 102 V, where the paper gives 140 V/cm for all. Not deciding - with 12 x 12 pixel boxes at the extremes of the smoothed ratio image, the means over the 22 groups (scaled, free discharging amplitude) are 1.10 +- 0.39 and 1.49 +- 0.18 us (cathodic charging and discharging) and 3.92 +- 1.53 and 1.45 +- 0.23 us (anodic); no selection, scaling or fit puts any of the four within the paper's SEM, 16 of 176 charging fits end at the 20-us bound, and the medians are 0.37 to 0.49 (cathodic) and 0.57 to 1.02 us (anodic) for charging and 0.81 to 1.79 us for discharging. Recorded as not reproduced in the first round; blocked after the verifier's round 1, as the time constants depend on ROIs and a selection the dandiset does not give.

  • Blocked

    Across 9 cells FluoVolt sensitivity to 2-us pulses was 15% to 47% per 1 kV/cm (mean 28%); sensitivity to 2-kHz sine waves, linearly correlated with the field, was 1.5% to 28.4% (mean 11.8%), smaller in every ROI, and 42% of the pulse value.

    Six of the criterion's seven parts are values (means, ranges, ratio, the count of cells with p below 0.0001)…

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraphs 5 and 6; Figures 6B to 6Dverifier disagreed at firstdata in DANDI:001274 (0.250805.1401), assigned from its titlefig6-sine-less-than-pulse
    From the paper

    The electric field sensitivity of FluoVolt ranged between a 15% and 47% change per 1 kV/cm, with an average value of 28% ± 2.5% across all ROIs in all the cells ... The regression coefficient, which was the FluoVolt sensitivity to sine waves, varied from 1.5% to 28.4% ( Figure 6C ). All numbers were invariably smaller than those measured for the same ROIs with the pulse ( Figure 6D ). The electric field sensitivity averaged across all ROIs in all the cells was 11.8% ± 1.7% per 1 kV/cm, just 42% of the value for the 2-μs pulses

    Result

    Six of the criterion's seven parts are values (means, ranges, ratio, the count of cells with p below 0.0001) measured in the paper's hand-drawn ROIs on the paper's nine cells, and the dandiset holds neither the ROIs nor the cell labels; the sensitivities are also divided by the paper's nominal fields, scaled by generator voltage, as 001274 gives no measured amplitudes. Not deciding - sine sensitivity is below pulse sensitivity in all 18 ROIs of the nine cells under the signed regression (15 of 18 under the per-cycle reading). With the 12 x 12 boxes the values are lower than the paper's - pulse 17.4 % per kV/cm (3.14 to 29.2; paper 28, 15 to 47), sine 5.55 % (0.04 to 14.8; paper 11.8, 1.5 to 28.4), ratio 32 % (paper 42 %) - and the regression reaches p < 0.0001 in both ROIs in 4 cells, not 8 (scaled, span 2 ms, signed regression, given as measured). These values depend on the ROIs, which the paper drew by hand and the dandiset does not hold - with 6 x 6 and 20 x 20 boxes at the same centres the pulse mean is 16.9 and 13.3 %, the sine mean 5.96 and 4.98 %, the ratio 35.2 and 37.6 %, 1 and 4 cells reach p < 0.0001 in both ROIs, and the sine value is below the pulse in 17 and 18 of 18 ROIs - and the nine cells are inferred, so the sizes cannot be judged, as for fig4-pooled-time-constants. The fitted carrier phases lie at -1.8 to -3.1 rad (ROI 1, all 9 cells) and 0.1 to 0.9 rad (ROI 2, 7 cells), near antiphase in those 7; 4_20240523 is nearly in phase (-2.70 and -2.13 rad) and 2_20240523 in quadrature (-3.14 and 1.56 rad). At the fitted phase the sine sensitivity averages 6.4 to 6.5 % (ratio 37 %), below the pulse in 18 of 18 ROIs. The pulse starts at frame 20, as the file description says (the binned pulse dF). The direction holds in every ROI under the signed regression, at the fitted phase and under every box size but the smallest (17 of 18), and in 15 of 18 under the per-cycle reading; it is the only part that does not rest on the paper's ROIs, and as it fails under the per-cycle reading it cannot carry the claim under a criterion that asks for every part under every reading. Under the per-cycle reading no cell reaches p < 0.0001 in both ROIs. With the full peak-to-peak amplitude, as the criterion names it, the per-cycle sine mean is 13.7 to 16.2 %, the ratio 79 to 93 %, and the sine value is below the pulse in 12 or 13 of 18 ROIs. Recorded as partially reproduced in rounds 1 and 2; blocked after the verifier's round 3, as for fig4-pooled-time-constants.

    Deviations from the paper’s method
    • ROIs are 12 x 12 pixel boxes centred on the extremes of the paper's RATIO image inside the cell; the paper drew ROIs by hand over the most polarized regions, with no size given. This is an assumption, and the sensitivities depend on it; 6 x 6 and 20 x 20 boxes are shown as a variant.
    • No debris ROI is marked; frames are scaled to the image median (reading a) or not scaled (b).
    • The nine cells are those of 001274 with a pulse and 100-Hz modulated waves without TTX; the files do not label them C1 to C9.
    • Fields are the paper's 257 V/cm (pulse) and 136 V/cm peak (sine), scaled by the generator voltage for the two cells run at 5 V (sine) and 15 V (pulse), as 001274 gives no measured amplitudes; the carrier phase is taken as zero at the first frame, checked above.
    • The LOESS is R's loess (degree 2, tricube weights, no robustness iterations), as the paper ran RStudio (Table S1), with the claims file's spans of 2 and 4 ms (O6); the first round used statsmodels' lowess.
    • Four sine sessions per cell are averaged (five in 2_20240522); the paper averaged 4 to 12.
    • The per-cycle reading (b) regresses half the cycle's peak-to-peak amplitude on its peak field, so that it is on the scale of the signed regression; the criterion names the peak-to-peak amplitude. With the full amplitude the reading-(b) sine values and ratio double, the p-values are the same, and the sine value is below the pulse in 12 or 13 of 18 ROIs, not 15; the notebook prints that variant, and no criterion row holds under it either.
  • Blocked

    The 2-kHz AP threshold of 57.7 V/cm times the sine wave sensitivity gives a 0.68% emission change, about 6.8 mV with FluoVolt's calibration, so the threshold depolarization is 5 to 15 mV, as with intracellular current injection.

    The estimate needs the 2-kHz AP threshold in V/cm.

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, last paragraphverifier disagreed at firstdata in DANDI:001032 to 001035 (0.240527.1431 or 0.240527.1432) for the threshold and DANDI:001274 (0.250805.1401) for the sensitivity, assigned from their titlesthreshold-depolarization-estimate
    From the paper

    This threshold corresponds to a 0.68% ± 0.11% FluoVolt emission change (11.8 × 57.7/1,000) ... Then, a 0.68% emission change corresponds to a 6.8-mV depolarization at the AP threshold. Considering the calibration factor variability, the threshold TMP depolarization can be conservatively estimated in the range from 5 to 15 mV

    Result

    The estimate needs the 2-kHz AP threshold in V/cm. The files give labelled generator voltages and "1V translates into 36 V/cm" without saying whether of the amplitude or the peak-to-peak value, and say the delivered amplitude is "somewhat smaller", the calibration not being deposited; the outcome changes with the field reading. Not deciding - with the signed-regression sine sensitivity (5.55 %) and the 1-AP threshold under the amplitude reading (76.0 V/cm, crop ROI) the emission change is 0.42 % and 4.2 mV (0.50 % and 5.0 mV with the 5-AP threshold); the peak-to-peak reading gives 0.84 to 1.46 %; 20 of 24 combinations with the per-cycle slope under the amplitude reading are in range, none otherwise. With the paper's own 57.7 V/cm the emission is 0.32 to 0.47 %. Recorded as not reproduced in the first round; blocked after the verifier's round 1.

Not tested in a notebook 5

2 other, 3 metadata insufficient

Blocked5

  • Blocked

    Replacing NaCl with sodium gluconate, which lowered the solution conductivity from 16.4 to 8.4 mS/cm, reversibly lowered excitation thresholds about 2-fold at every sine wave frequency from 2 to 20 kHz.

    None of the ten dandisets the paper lists holds 250-ms sessions in the low-conductivity (sodium gluconate)…

    OtherResults, Decreased extracellular conductivity lowers excitation thresholds, paragraph 2; Figures 3A and 3Bdata in DANDI:001030 (0.240520.1924) and 001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig3b-low-conductivity-halves-threshold
    From the paper

    Switching to the NaGlu-based solution reversibly and reproducibly decreased excitation thresholds ~2-fold across all sine wave frequencies tested

    Result

    None of the ten dandisets the paper lists holds 250-ms sessions in the low-conductivity (sodium gluconate) solution. 001032, 001033 and 001035 are all NaCl (625 sessions); 001030 holds only the 2-s ramped waves of Figure 3C, and 001031 100-kHz pulses. The data the claim needs are not public. The reason would be data_missing, which the registry's checks do not allow for a claim marked data elsewhere.

  • Blocked

    Extrapolated to a 2 mS/cm solution, excitation by 2-kHz sine waves would be expected at about 7 V/cm.

    Depends on fig3b-low-conductivity-halves-threshold, blocked because the low-conductivity 250-ms sessions are…

    OtherResults, Decreased extracellular conductivity lowers excitation thresholds, paragraph 2data in DANDI:001030 (0.240520.1924) and 001032 to 001035 (0.240527.1431 or 0.240527.1432), assigned from their titlesfig3-extrapolated-threshold
    From the paper

    Extrapolating this trend to still lower conductivities, excitation by 2-kHz sine waves would be expected at ~7 V/cm in a 2 mS/cm solution

    Result

    Depends on fig3b-low-conductivity-halves-threshold, blocked because the low-conductivity 250-ms sessions are not deposited.

  • Blocked

    Aligning elongated cells with the field doubled the time constants compared with the same cells perpendicular to it or with randomly shaped cells; dFmax and the time constants did not differ between the cathode- and anode-facing poles; and discharging was slower than charging except in elongated cells aligned with the field.

    The files do not say which cells are elongated or random, nor how a cell's long axis lies with respect to the…

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, the two paragraphs after the Figure 4 legend; Figures 4D and 4E and legenddata in DANDI:001273 (0.250805.1356), assigned from its titlefig4-orientation-and-poles
    From the paper

    Δ F max did not differ at the cathodic and anodic cell poles, indicating the lack of rectification of the applied electric field. Charging and discharging time constants did not differ between the two poles either. Aligning elongated cells with the electric field doubled the time constants, as compared to either the same cells oriented perpendicular to the field ( p < 0.001, paired t test) or to randomly shaped cells ( p < 0.01, unpaired t test). Interestingly, discharging time constants were always larger than the charging ones in the same cell ( p < 0.001, paired t test), with the exception of elongated cells aligned with the field

    Reported statistics
    • elongated cells, parallel against perpendicular time constants: paired t test, p < 0.001 (n = 3 parallel and 6 perpendicular experiments)
    • elongated parallel against random cells: unpaired t test, p < 0.01 (n = 3 parallel and 10 random experiments)
    • discharging against charging time constants: paired t test, p < 0.001
    Result

    The files do not say which cells are elongated or random, nor how a cell's long axis lies with respect to the up/bottom and right/left electrode pairs (and on 2024-01-17 the electrode position is not specified), so the parallel, perpendicular and random groups cannot be formed. Shown in the notebook, not deciding - over the 22 groups the pole difference in dFmax is not significant (paired p = 0.053), nor in charging (p = 0.105) or discharging tau (p = 0.917), and discharging does not exceed charging significantly (p = 0.119 anodic, 0.368 cathodic).

  • Blocked

    Sine waves polarized the two poles of a cell more asymmetrically than 2-us pulses; in the Figure 5 cell the depolarized ROI 2 was 30% smaller than the hyperpolarized ROI 1 with the pulse and up to 90% smaller with sine waves, and in the Figure S3 cell the hyperpolarized ROI 1 was 20% smaller than the depolarized ROI 2 with the pulse and 40% smaller with sine waves, the oscillations not migrating to other regions.

    The claim is about the Figure 5 and S3 cells (C7 and C8 of Figure 6B).

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraphs 1 to 4; Figures 5 and S3data in DANDI:001274 (0.250805.1401), assigned from its titlefig5-sine-asymmetry
    From the paper

    in this cell, the oscillations in ROI 2 were up to 90% smaller than those in ROI 1 (compared to just 30% smaller when the same cell was polarized with the 2-μs pulse) ... With the 2-μs pulse, polarization in ROI 1 was 20% smaller than in ROI 2 ( Figure S3B ); however, with sine waves, it became 40% smaller

    Result

    The claim is about the Figure 5 and S3 cells (C7 and C8 of Figure 6B). The files do not identify them, and the Figure 5 cell's 12 sine sessions match no cell in 001274 (five at most at 100 Hz, in 2_20240522). For the nine cells taken as Figure 6's, the pulse asymmetry is 10.8 to 69.2 % and the sine asymmetry 4.6 to 99.7 % (shown in the notebook, not deciding).

  • Blocked

    During a single beat of a modulated 2-kHz sine wave, the optical TMP in ROIs 1 and 2 oscillated with the carrier in opposite phases, with amplitudes proportional to the sine wave amplitude, on top of a gradual depolarization of the whole cell that developed as the amplitude rose.

    Same cells as fig5-sine-asymmetry, not identifiable.

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 2; Figures 5C, 5D and legend; Figure S3data in DANDI:001274 (0.250805.1401), assigned from its titlefig5-whole-cell-depolarization
    From the paper

    Optical TMP oscillated in synchrony with the carrier sine wave in the opposite phases, i.e., the peak depolarization in ROI 1 corresponded to the peak hyperpolarization in ROI 2, and vice versa. These oscillations, proportional to the sine wave amplitude, were superimposed on the gradual depolarization of the entire cell

    Result

    Same cells as fig5-sine-asymmetry, not identifiable. For the nine cells (not deciding), the signed sine slopes of ROI 1 and ROI 2 have opposite signs in 8, and the fitted carrier phases of the two ROIs lie near antiphase in 7 (4_20240523 is nearly in phase, -2.70 and -2.13 rad, and 2_20240523 in quadrature, -3.14 and 1.56 rad). The Pearson correlation of the whole oscillation traces, which include everything the LOESS leaves, is negative in 2 (p < 0.05) and up to 0.66 in cells whose carriers are near antiphase; why is not shown. The LOESS fit at the envelope peak is above F0 in both ROIs in 2 cells.

Attempt semenov-2025-02, on DANDI:001271 version 0.250805.1352

Reproducing Semenov et al. (2025), Figure S2, from dandiset 001271 8 Open in Colab

Reproduced1

  • Reproduced

    The tetrodotoxin experiment was replicated in several neurons, with vehicle controls; the representative traces of Figure S2 come from at least 4 independent replications in different cells.

    6 TTX neurons (two on each of 30 July, 31 July and 1 August 2024) and 11 vehicle neurons with a visible…

    Figure S2 legend; Methods, Quantification and statistical analysisverifier disagreed at firstfigs2-neurons-tested
    From the paper

    Representative traces of the optical membrane potentials were selected from at least 4 and usually 8-15 independent replications in different cells

    Result

    6 TTX neurons (two on each of 30 July, 31 July and 1 August 2024) and 11 vehicle neurons with a visible solution change, so both readings hold (TTX at least 4, and TTX and vehicle together at least 4). Three more neurons are labelled vehicle but show no gap over 3 minutes. Each subject is one neuron (every session's least similar session of its own subject is more similar than any session of another subject), and all 287 data arrays are distinct.

    Deviations from the paper’s method
    • The files do not mark the solution change. For TTX neurons it is the first session labelled with TTX; for vehicle neurons it is placed at the last gap of more than 3 minutes between sessions (an assumption; the Methods give 20 to 60 s between sessions and the TTX neurons' gaps before TTX are 3.6 to 10.0 minutes). Three vehicle-labelled neurons have no such gap and count as having no change. Reading (a) does not depend on it.

Not reproduced1

  • Not reproduced

    Before the drug, unmodulated 2-kHz sine waves evoked repetitive APs at lower fields and, at the most intense fields, a sustained depolarization in which APs merged into small oscillations.

    Each of the 16 combinations of the claims file's readings (O1 to O4) gives not reproduced, and the criterion…

    Results, Tetrodotoxin blocks sustained depolarization, paragraph 1; Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Figure S2verifier disagreed at firstquestion to the readerfigs2-before-firing-then-depolarization
    From the paper

    Not quoted: The paper states this pattern for Figures 1 and 3 ("At the highest field strengths, multiple APs coalesced into low-amplitude oscillations on top of a continuous depolarization"); for the Figure S2 neurons it is shown only in the traces before the change, and the legend's "abolishes both firing and sustained depolarization" implies both were present before.

    Result

    Each of the 16 combinations of the claims file's readings (O1 to O4) gives not reproduced, and the criterion has no partial outcome; the 8 rows of the whole-frame variant fail too. Firing before the change holds under some readings only. With O1(a) every neuron fires with the 5% height (20 of 20) and 18 or 19 of 20 with the 5-SD height, and 18 to 20 have APs without sustained depolarization at a lower field; with O1(b) all 7 fire with the 5% height and 1 of 7 with the 5-SD height. No neuron shows sustained depolarization (O4) at its highest field under any reading (0 of 20; 0 of 7 under O1(b)), where the criterion needs more than half. At the highest field the mean dF over the last 100 ms of the stimulus is above zero in 20 of 20 neurons (median 2.63%, range 0.55 to 5.41% with O1(a)), below both O4 levels (medians 7.29% and 4.93%), and 9 of the 20 still have an AP in that window. The whole-frame variant finds 1 of 20. Against a baseline without depolarization, the median of the same window over every session after TTX (-0.60%, as in the 5 sham sessions, -0.54 to -1.14%), the highest field raises dF in 20 of 20 neurons by 1.15 to 6.01 points with O1(a), below both O4 levels in every neuron. The depolarization the paper describes is present but smaller than the levels of the claims file's measure, which cannot detect plateaus of this size in these recordings; the failed part says the measure finds none, not that the data show none. The maximum firing rate rises with field in most neurons (tables in the notebook). Whether O4 suits these data is asked of a reader (questions/001271.yaml).

    Deviations from the paper’s method
    • The files hold 16 x 16 crops and no soma outline, where the paper drew the soma on 64 x 64 images; the claims file's ROI readings O1 were run as written. The Otsu component nearest the centre is often a few pixels of bright membrane, and the 2-pixel erosion of O1(b) is empty in 210 of 287 sessions of 001271, which are dropped from that reading. The whole frame is shown as a variant that decides nothing.
    • Frames 0 and 1199 of every file are left out of every trace (frame 0 is 1.8 to 8.6 times the mean of the others, the last frame 3 to 8% above the one before), a choice of this attempt; the paper does not mention them.
    • The three vehicle-labelled neurons with no visible change are included (all their sessions are before any change); without them the outcome is the same (0 or 1 of 17).

Blocked6

  • Blocked

    The sustained depolarization induced by intense unmodulated sine waves reversed immediately when the stimulus ended, so it was not membrane electroporation, which would take seconds or longer to repair.

    No session qualifies. The criterion judges sessions with sustained depolarization (O4), and under every…

    OtherResults, Tetrodotoxin blocks sustained depolarization, paragraph 1verifier disagreed at firstfigs2-depolarization-reversible
    From the paper

    The sustained depolarization induced by intense unmodulated sine waves ( Figures 1 and 3 ) was immediately reversible upon stimulus cessation. It was not related to membrane electroporation, which would take seconds or longer to repair

    Result

    No session qualifies. The criterion judges sessions with sustained depolarization (O4), and under every combination of the claims file's readings there are none, so the claim cannot be tested. The whole-frame variant finds 2 or 3 such sessions under its 5-SD readings, and in each dF falls below the O4 level in both windows after the stimulus. Not judged, at each neuron's highest field dF drops from the last 100 ms of the stimulus to 10 to 40 ms after it in 20 of 20 neurons (median drop 3.04 points), and the next session's F0 is within 10% of the one before in 246 of 262 consecutive pairs.

    Deviations from the paper’s method
    • The files hold 16 x 16 crops and no soma outline, where the paper drew the soma on 64 x 64 images; the claims file's ROI readings O1 were run as written. The Otsu component nearest the centre is often a few pixels of bright membrane, and the 2-pixel erosion of O1(b) is empty in 210 of 287 sessions of 001271, which are dropped from that reading. The whole frame is shown as a variant that decides nothing.
    • The claim is tested on the Figure S2 neurons, while the paper's sentence cites Figures 1 and 3 (as the criterion says).
  • Blocked

    1 uM tetrodotoxin abolished the APs evoked by unmodulated 250-ms, 2-kHz sine waves.

    The claims file's readings give different outcomes, and its header blocks a claim when they do.

    Methods underspecifiedResults, Tetrodotoxin blocks sustained depolarization, paragraph 1; Figure S2 legendverifier disagreed at firstquestion to the readerfigs2-ttx-abolishes-aps
    From the paper

    the inhibition of sodium channels with 1 μM tetrodotoxin not only abolished the APs

    Result

    The claims file's readings give different outcomes, and its header blocks a claim when they do. With the O1(a) ROI no AP is found after TTX at the highest common voltage (O5 b, 6 pairs), but over every common voltage (O5 a, 31 pairs) one pair has a single peak after TTX, 19.7 to 21.3% high and 2.8 ms wide, in a 14_20240731 session whose O1(a) ROI is one pixel (pre-stimulus SD 11.8%); these readings find 158 to 204 APs before TTX. With the O1(b) ROI, left with 3 TTX neurons, the 5% height finds peaks 2.0 to 3.9 ms wide after TTX in 9 of 12 pairs, in ROIs whose pre-stimulus SD is about 3 to 12%, and the 5-SD height finds none. In the whole-frame variant no AP is found after TTX in any of 31 pairs under any reading, against 215 to 253 before. The open detail is the soma ROI (methods_unavailable finding). The plotted trace of the one O1(a) AP after TTX is noise (one-pixel ROI, swings of about 40%), and the peak does not pass the session's own 5-SD level (58.9%); no session after TTX has an AP at its own 5-SD level under either claims-file ROI. O3 of the claims file sets the level after TTX from the neuron's sessions before, so the readings are kept as written and still disagree.

    Deviations from the paper’s method
    • The files hold 16 x 16 crops and no soma outline, where the paper drew the soma on 64 x 64 images; the claims file's ROI readings O1 were run as written. The Otsu component nearest the centre is often a few pixels of bright membrane, and the 2-pixel erosion of O1(b) is empty in 210 of 287 sessions of 001271, which are dropped from that reading. The whole frame is shown as a variant that decides nothing.
    • Frames 0 and 1199 of every file are left out of every trace (frame 0 is 1.8 to 8.6 times the mean of the others, the last frame 3 to 8% above the one before), a choice of this attempt; the paper does not mention them.
    • Where a voltage was tested more than once in a phase, APs count when any session has them (a standard choice).
  • Blocked

    Tetrodotoxin also fully blocked the sustained depolarization caused by intense sine waves, consistent with the depolarization arising from repeated activation of voltage-gated sodium channels by the cycling de- and hyperpolarization of the membrane.

    The criterion blocks the claim (other) when no TTX neuron has sustained depolarization (O4) before TTX, and…

    OtherResults, Tetrodotoxin blocks sustained depolarization, paragraph 1; Figure S2 legendfigs2-ttx-blocks-sustained-depolarization
    From the paper

    Consistent with this hypothesis, the inhibition of sodium channels with 1 μM tetrodotoxin not only abolished the APs but also fully blocked the sustained depolarization

    Result

    The criterion blocks the claim (other) when no TTX neuron has sustained depolarization (O4) before TTX, and none has under any combination of the claims file's readings. In the whole-frame variant one TTX neuron qualifies under the 5-SD level and loses it after TTX. Not judged, the mean dF over the last 100 ms of the stimulus falls after TTX at the same voltage under every reading (whole frame, 31 pairs, 1.31% before against -0.59% after, paired t p = 1.6e-07; O1(a) 1.21% against -0.64%, p = 9.5e-07) and is below zero after TTX at every voltage up to 10 V; in vehicle pairs it falls from 1.80% to 1.55% (p = 0.00054). Before TTX the six TTX neurons' highest fields raise dF by 1.15 to 6.01 points over the after-TTX baseline with O1(a), below both O4 levels in each, so the measure has no depolarization to follow through TTX.

    Deviations from the paper’s method
    • The files hold 16 x 16 crops and no soma outline, where the paper drew the soma on 64 x 64 images; the claims file's ROI readings O1 were run as written. The Otsu component nearest the centre is often a few pixels of bright membrane, and the 2-pixel erosion of O1(b) is empty in 210 of 287 sessions of 001271, which are dropped from that reading. The whole frame is shown as a variant that decides nothing.
    • After the change the 5-SD level of O4(a) is the median pre-stimulus SD of the neuron's sessions before the change, as O3 has it for APs, an extension of O3 to O4 assumed by this attempt. It does not change the outcome, as no pair qualifies before TTX.
  • Blocked

    In vehicle controls, recorded about 5 min after the solution was replaced by the same solution without TTX, the firing and sustained depolarization persisted.

    The readings of which pairs are compared (O5) disagree.

    Methods underspecifiedFigure S2 legend; Methods, Quantification and statistical analysisverifier disagreed at firstfigs2-vehicle-keeps-response
    From the paper

    Not quoted: No sentence states the vehicle result. The Figure S2 legend says the neurons were recorded again after replacement by the same solution "with 1 μM TTX or without it (vehicle control)", the Methods list "vehicle controls in experiments with tetrodotoxin", and the legend's title attributes the loss of firing and depolarization to TTX, which implies the vehicle neurons kept them; Figure S2 shows this in one neuron.

    Result

    The readings of which pairs are compared (O5) disagree. Over every common voltage (O5 a) some pairs with APs before have none after (3 or 4 of 50 to 59 under O1(a), 1 of 9 under O1(b) with the 5% height, 2 of 59 in the whole frame), all near threshold, so the claim fails there; at the highest common voltage (O5 b) every pair keeps its APs under O1(a) with the 5-SD height, and 1 of 11 loses them with the 5% height. No vehicle pair has sustained depolarization (O4) before, so that part is empty. Under O1(a) with the 5% height vehicle neurons fire 334 APs before and 327 after over 59 pairs (p = 0.77). Per neuron, all 11 vehicle neurons fire after the change under O1(a) with the 5% height, and 8 of 11 keep APs in every pair that had them; with the 5-SD height 9 of 11 fire after it and the other two have no AP before either. Placing the change of 13_20240801 at its largest gap (10.8 min, leaving one session before) instead of its last (5.0 min) takes its lost pairs under O1(a) from 1 or 2 to 0, and the O5 readings still disagree in other neurons. The paper does not say which sessions it compared (methods_unavailable finding).

    Deviations from the paper’s method
    • The files hold 16 x 16 crops and no soma outline, where the paper drew the soma on 64 x 64 images; the claims file's ROI readings O1 were run as written. The Otsu component nearest the centre is often a few pixels of bright membrane, and the 2-pixel erosion of O1(b) is empty in 210 of 287 sessions of 001271, which are dropped from that reading. The whole frame is shown as a variant that decides nothing.
    • The files do not mark the solution change. For TTX neurons it is the first session labelled with TTX; for vehicle neurons it is placed at the last gap of more than 3 minutes between sessions (an assumption; the Methods give 20 to 60 s between sessions and the TTX neurons' gaps before TTX are 3.6 to 10.0 minutes). Three vehicle-labelled neurons have no such gap and count as having no change. This assumption does not decide the outcome, which is blocked whichever change point 13_20240801 is given.
  • Blocked

    Neurons were selected for APs peaking above 5% dF and lasting about 10 ms; typical APs were 11.3% dF high and 8 ms long, excluding the afterhyperpolarization.

    One of 32 combinations of the claims file's readings (O1 a, F0 over all frames, 5-SD height, first AP of each…

    Methods underspecifiedMethods, Recording of the optical APs and data analysesverifier disagreed at firstap-amplitude-duration
    From the paper

    we selected neurons whose APs peaked at a more than 5% Δ F and lasted about 10 ms (typical values ... 11.3% ± 0.9% Δ F and 8 ± 0.7 ms duration, excluding afterhyperpolarization ... mean ± SEM, n = 22)

    Result

    One of 32 combinations of the claims file's readings (O1 a, F0 over all frames, 5-SD height, first AP of each session, duration to the return to F0) gives means within the paper's SEM (10.76% and 7.62 ms over 18 neurons); the other 31 do not, and the criterion blocks the claim when the readings disagree. With O1(a) mean peaks are 9.29 to 10.82% and widths at half height 3.56 to 4.06 ms (about half the paper's 8 ms); durations to F0 are 6.52 to 9.28 ms. With O1(b) (7 neurons, 1 with the 5-SD height) peaks are 15.8 to 18.9%. In the whole frame peaks are 7.67 to 9.54%. The dataset's neurons are not known to be among the paper's 22.

    Deviations from the paper’s method
    • The files hold 16 x 16 crops and no soma outline, where the paper drew the soma on 64 x 64 images; the claims file's ROI readings O1 were run as written. The Otsu component nearest the centre is often a few pixels of bright membrane, and the 2-pixel erosion of O1(b) is empty in 210 of 287 sessions of 001271, which are dropped from that reading. The whole frame is shown as a variant that decides nothing.
    • The paper's 22 neurons are not identified; the 20 neurons of this dataset are used, as the criterion says.
  • Blocked

    Excitation by pure sine waves was not caused by heating; the adiabatic temperature rise was 2.5 C after 250 ms at 63 V/cm in NaCl solution, at most 1.24 C for the same stimulus in the low-conductivity solution, and 4.1 C at 81 V/cm in NaCl.

    Neither reading gives the paper's temperatures (peak field 3.89, 1.99 and 6.44 C; RMS field 1.95, 1.00 and…

    Methods underspecifiedResults, Decreased extracellular conductivity lowers excitation thresholds, paragraph 2; Figure 3Averifier disagreed at firstdata in DANDI:001030 or 001032 to 001035 for the Figure 3A responses (assigned from their titles); the temperatures are calculated from the field, duration and conductivity, not measuredfig3-not-heating
    From the paper

    the maximum theoretical temperature rise (assuming no heat dissipation 43 ) was 2.5°C after 250 ms of near-threshold stimulation at 2 kHz, 63 V/cm, in the NaCl-based solution ... These observations prove that excitation by pure sine waves was not caused by heating

    Result

    Neither reading gives the paper's temperatures (peak field 3.89, 1.99 and 6.44 C; RMS field 1.95, 1.00 and 3.22 C, against 2.5, 1.24 and 4.1 C), while the paper's ratios follow the formula (81 over 63 V/cm within 0.8%, NaGlu over NaCl within 3.2%), which the criterion rules blocked. 2.5 C would need a heat capacity of 6.51 MJ per m3 per K with the peak field or 3.25 with the RMS field, against 4.18 for water.

    Deviations from the paper’s method
    • Calculated from the paper's values; no data used.

Semenov et al. (2025), Figure 3C, from dandiset 001030 1 Open in Colab

Not reproduced1

  • Not reproduced

    In the low-conductivity solution, a 2-s unmodulated 2-kHz sine wave ramped over 250 ms evoked firing for its whole duration, rising with field until replaced by a firing block with sustained depolarization.

    Each of the 48 combinations of the claims file's readings gives not reproduced, and the criterion has no…

    Results, Decreased extracellular conductivity lowers excitation thresholds, paragraph 3; Figure 3Cverifier disagreed at firstdata in DANDI:001030 (assigned from its title)fig3c-sustained-firing-2s
    From the paper

    we observed sustained firing for the entire duration of the sine wave ( Figure 3C ). The rate of firing increased with the electric field strength until it was replaced by a firing block and sustained depolarization

    Result

    Each of the 48 combinations of the claims file's readings gives not reproduced, and the criterion has no partial outcome. The first two parts fail only with O1(b) and the 5-SD height; with O1(b) and the 5% height both remaining cells meet both. With O1(a), under every F0, height and bleaching reading, c7 (the cell with six fields, 1.0 to 2.3 V) has APs in the last 250 ms of the 2-s wave at an intermediate field and an AP count that rises from its lowest field; with the 5% height all four cells do, and with the 5-SD height 1 to 3 cells meet the first part and 3 or 4 the second. With O1(b) and the 5-SD height no cell meets the first part. The third part fails in every reading, in the claims file's ROIs and the whole frame. No cell's highest field meets sustained depolarization (O4), so the criterion is not met for one cell or for every cell. In c7 firing drops at 2.3 V (16 APs with O1(a), against 70 to 90 at 1.45 to 2.0 V), with O1(a) its mean dF over the last 250 ms (1.7 to 7.1%) stays below the O4 levels (6.5 to 14.5%), and in the whole frame it is 6.0%, above the 5-SD level, but a single 8.0% peak in the window counts as an AP. The O1(b) ROI leaves two cells, not c7. With bleaching reading (c), a reference smoothed by a 101-ms running median, c7 is corrected under every reading and its mean dF over the last 250 ms at 2.3 V is 6.97 to 7.07%, below the O4 levels (7.93 to 13.28%); the 5-SD level drops little (13.28 against 13.73% with the raw reference under O1(a), F0 all, 5-SD height). In the whole frame reading (c) lets one cell, c8, meet all three parts with F0 over the last 20 ms (a variant). Whether O4, with its no-AP condition, suits the paper's firing block is asked of a reader (questions/001271.yaml).

    Deviations from the paper’s method
    • Only c7 has an AP-free session for the bleaching correction; for the other cells readings (a) no correction and (b) subtracting c7's 1.0-V trace are both run. Reading (c) subtracts the reference after a 101-ms running median, which keeps the slow bleaching and drops the frame noise and a single AP, so that c7's 1.0-V session can serve when it holds one AP; it is the cell's own AP-free session, else c7 at 1.0 V.
    • Which neurons are judged is not given (Figure 3C shows one); readings (a) at least one neuron and (b) every neuron with three or more fields are both run and agree.
    • The c5 recordings at 1.5 and 2.0 V end at 1,914 ms, before the stimulus ends at 2,025 ms; their last-250-ms window is cut to 139 ms.
    • Tested on DANDI:001030; fields are the stated one-polarity voltages.

Semenov et al. (2025), Figures 1, 2 and S1, from dandisets 001032 to 001035 and 001272 7 Open in Colab

Reproduced2

  • Reproduced

    With 20-Hz modulation, firing above threshold locked to the beats, one AP near the peak of each of the five beats and at most two per beat (ten in all), and modulated sine waves triggered no sustained firing or sustained depolarization.

    Tested on the criterion as amended after the reader's answer in questions/001271.yaml.

    Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 1; Figures 2A and 2Brests on an assumptionquestion to the readerdata in DANDI:001032 to 001035 (assigned from their titles)fig2-modulated-locks-to-beats
    From the paper

    single APs emerged near the peak of each beat, so the firing rate equaled the modulation rate ... the maximum number of APs evoked by five beats was limited to ten. Unlike pure sine waves, modulated stimuli did not trigger sustained firing or sustained depolarization

    Result

    Tested on the criterion as amended after the reader's answer in questions/001271.yaml. The first run, on the header's O4 definition of sustained firing (at least three APs with one in the last 50 ms), was partially_reproduced, assumed. The reader found that the definition misread the paper, which sets modulated firing against the sustained firing of pure sine waves, and amended the criterion. A modulated session now shows sustained firing when more than two APs fall in one beat or, with 5 APs or more, at least as many APs fall outside 12.5 to 37.5 ms of the beats as inside. Under it, 12 of the 16 readings pass, all four O1(a) readings with the 5-SD height and all eight O1(b) readings. Under O1(a) with the 5% height, 91% of 213 APs in 84 modulated sessions fall within 12.5 to 37.5 ms of a beat (49% of 1,383 APs for unmodulated waves), no session has more than 8 APs, all 15 sessions with 5 APs or more have most APs near the beat peaks, no session has as many APs outside that window as inside, and none shows sustained depolarization. The four O1(a) readings with the 5% height fail through a single session, subject 9_2 at 2 kHz and 3.4 V, with three APs in the fifth beat (206.4, 217.4 and 236.2 ms, peaks 11.1 to 22.2% dF). Its pre-onset SD is 9.8% dF, about twice the 5% level, and none of its peaks passes its 5-SD level (49.0% dF); the same neuron's unmodulated session at 3.4 V has a pre-onset SD of 1.40% dF and eight APs of 11.6 to 15.0% dF under both heights. The O4 definition would still flag 15 to 32 modulated sessions under O1(a); the amended rule flags 88 of the 197 unmodulated sessions with 3 APs or more, so it separates the two kinds of wave. What the answer changed is the test of sustained firing, and with it the outcome, from partially_reproduced to reproduced; the first run's assumption that O1(a) decides is no longer needed, as the O1(b) readings pass too.

    Deviations from the paper’s method
    • Assumed, the 5-SD height decides between the two AP heights of the header (O3), since the readings differ through one session whose pre-onset noise (SD 9.8% dF) is twice the 5% level, so that the 5% height counts noise peaks there as APs.
    • Tested on DANDI:001032, 001033 and 001035; 001034 duplicates 001032 and is counted once.
  • Reproduced

    In the same neuron at the same field strength, pure sine waves triggered more APs than modulated ones, and the threshold was typically lower for unmodulated signals.

    All 8 readings of the claims file pass with the 1-AP threshold.

    Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 2; Figures 2A to 2Crests on an assumptiondata in DANDI:001032 to 001035 (assigned from their titles)fig2c-pure-more-aps
    From the paper

    the threshold was typically lower for unmodulated signals ( Figures 2A - 2C ). At the same field strengths, pure sine waves triggered a larger number of APs

    Result

    All 8 readings of the claims file pass with the 1-AP threshold. With the O1(a) ROI the unmodulated wave gives more APs than the modulated one at the same carrier and voltage in 32 to 43 of 52 pairs (12 neurons) against 2 to 4 (paired t p = 4.7e-10 to 7.8e-07), and the unmodulated 1-AP threshold is lower in 10 to 13 of 12 to 15 neurons (0 to 2 the reverse). With O1(b) (5 neurons) the count is larger in 5 to 14 of 16 pairs against 1 to 3, and the 1-AP threshold lower in 3 to 6 of 3 to 7 neurons against 0 or 1. Requiring the 5-AP threshold too (a variant) passes the four O1(a) readings (2 to 6 of 4 to 9 neurons lower, none the reverse) and fails the four O1(b) ones, which have at most one 5-AP threshold pair. The first run required both thresholds and let O1(a) decide.

    Deviations from the paper’s method
    • Assumed, "the threshold" is the 1-AP excitation threshold. The paper determined "the minimal voltages eliciting 1 and 5 APs" (Methods, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves), and its "excitation thresholds" without a count (Results, Decreased extracellular conductivity lowers excitation thresholds; Figure 3B) are the 1-AP ones, as the fig3b criterion has it. The 5-AP threshold is shown as a variant.
    • Tested on DANDI:001032, 001033 and 001035; 001034 duplicates 001032 and is counted once.

Not reproduced4

  • Not reproduced

    Unmodulated 250-ms sine waves at 2 and 20 kHz excited every neuron tested, with APs 100 to 200 ms after onset near threshold, firing rate rising to a ceiling of 60 to 90 Hz, and sustained depolarization at the highest fields.

    No combination of the claims file's readings meets the criterion at both frequencies (0 of 16).

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Figures 1A to 1C and insetquestion to the readerdata in DANDI:001030 and 001032 to 001035 (assigned from their titles; the paper does not map figures to dandisets)fig1-pure-sine-excites-all
    From the paper

    Pure sine waves at 2 and even 20 kHz excited 100% of neurons ... at near-threshold electric field strengths, isolated APs emerged with a delay of 100-200 ms after the sine wave onset ... The maximum firing rate increased linearly until reaching a ceiling of 60-90 Hz

    Result

    No combination of the claims file's readings meets the criterion at both frequencies (0 of 16). The measured value is the 20-kHz excited fraction under the first reading (O1 a, F0 all, 5% height), 88.2% of 17 neurons; at 2 kHz it is 96.4% of 28. The median highest firing rate is 22.2 to 36.7 Hz under O1(a) (54 to 99 Hz needed; 1 to 5 neurons per frequency reach it) and the median first-AP latency at threshold 53.5 to 70.0 ms at 2 kHz and 67.4 to 123.8 ms at 20 kHz (90 to 220 ms needed). Under O1(b) (14 and 10 neurons) the ceilings are 21.7 to 53.9 Hz. Sustained depolarization at the highest field is found in at most one neuron (reported, not judged).

    Deviations from the paper’s method
    • Tested on DANDI:001032, 001033 and 001035; 001034 duplicates 001032 and is counted once.
    • The files hold 16 x 16 crops and no soma outline; the claims file's ROI readings O1 were run as written. The 2-pixel erosion of O1(b) leaves pixels in 245 of 624 sessions of 001032, 001033 and 001035; the others are dropped from that reading.
    • Thresholds and latencies come from the sessions as deposited (the lowest voltage with an AP), not from a threshold search the files record.
  • Not reproduced

    All excitation thresholds at 20 kHz were about 2-fold higher than at 2 kHz.

    20-kHz thresholds are higher than 2-kHz ones in every reading (pooled p < 0.0001 in 7 of 8 readings), but no…

    Results, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2Ddata in DANDI:001032 to 001035 (assigned from their titles)fig1-20khz-needs-twice-the-field
    From the paper

    All thresholds at 20 kHz were about 2-fold higher than at 2 kHz ( p < 0.0001, two-tailed unpaired t test)

    Reported statistics
    • 20 kHz against 2 kHz, all thresholds: two-tailed unpaired t test, p < 10⁻⁴
    Result

    20-kHz thresholds are higher than 2-kHz ones in every reading (pooled p < 0.0001 in 7 of 8 readings), but no reading has all four ratios within 1.8 to 2.2 (6 of 32 stimulus and AP-count rows are), so the criterion fails under every reading. The measured value is the unmodulated 1-AP ratio under the first reading (2.16; 2.15 to 2.19 with the 5% height, 2.56 or 3.51 to 3.53 with the 5-SD height). Unmodulated 5-AP ratios are 2.06 to 2.84 and modulated ones 2.24 to 2.96, from 1 to 3 neurons with modulated 20-kHz thresholds (0 or 1 for 5 APs, where there is no ratio when there are none). Without the 20-kHz sessions of 13_1, which show the cell of 14_1, 0 or 1 of the four ratios is within 1.8 to 2.2 in each reading (a variant). The ratios are of the stated generator voltages; the files say the actual amplitude is smaller by a frequency-dependent factor they do not give, so the field ratio may differ.

    Deviations from the paper’s method
    • Tested on DANDI:001032, 001033 and 001035; 001034 duplicates 001032 and is counted once.
    • Thresholds are in stated generator volts; the frequency-dependent calibration to the actual field is not given in the files.
  • Not reproduced

    Thresholds for sine waves modulated at 20 Hz were significantly higher than for pure sine waves at the same carrier, for 5 APs at 2 kHz and for 1 and 5 APs at 20 kHz, so modulation did not lower excitation thresholds; the 2-kHz unmodulated 1-AP threshold was 57.7 V/cm.

    Under no reading do the three comparisons the paper reports as significant all hold.

    Results, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2D; Results, Asymmetric and less-efficient membrane charging, last paragraphdata in DANDI:001032 to 001035 (assigned from their titles)fig2d-modulated-thresholds-higher
    From the paper

    thresholds for modulated sine waves, which emulate the TI stimulus at the target, were significantly higher than those for pure sine waves at the same frequency ... p = 0.0079 ... p = 0.0142 and p = 0.0037

    Reported statistics
    • modulated against unmodulated, 2 kHz, 5 APs: two-tailed unpaired t test, p = 0.0079
    • modulated against unmodulated, 20 kHz, 1 AP: two-tailed unpaired t test, p = 0.0142
    • modulated against unmodulated, 20 kHz, 5 APs: two-tailed unpaired t test, p = 0.0037
    Result

    Under no reading do the three comparisons the paper reports as significant all hold. Modulated thresholds are higher on average wherever they can be compared except at 20 kHz with 1 AP under O1(b) with the 5-SD height (12.00 or 11.93 V unmodulated against 11.00 V for the one modulated neuron). The 2-kHz 5-AP difference is not significant (p = 0.082 to 0.28 under O1(a)), and only 1 to 3 neurons have modulated 20-kHz 1-AP thresholds and 0 or 1 have 5-AP ones (1-AP p = 0.013 with the 5% height under O1(a), 0.80 with the 5-SD height; the 5-AP test cannot be run). Without the 20-kHz sessions of 13_1 the tests fail in every reading too (a variant). The 2-kHz 1-AP threshold is not lower for modulated waves in any reading. The measured value is the mean 2-kHz unmodulated 1-AP threshold under the first reading at 18 V/cm per V, 74.1 V/cm (74.1 to 79.0 under O1(a), 61.2 to 67.6 under O1(b), twice these at the files' 36 V/cm per V), against 57.7 +/- 3.6.

    Deviations from the paper’s method
    • Tested on DANDI:001032, 001033 and 001035; 001034 duplicates 001032 and is counted once.
    • Fields use 18 V/cm per stated volt, the scale at which 001271's voltages give the fields of Figure S2; the files state 36 V/cm per V, also shown. The 18 V/cm scale is an assumption of this attempt; the outcome is the same at both scales, so it does not rest on it.
    • Subject 13_1 of 001032 is counted as one neuron as deposited, though its 20-kHz sessions show another cell; without them the outcome is the same.
  • Not reproduced

    With Di-8-ANEPPS in place of FluoVolt, in eight neurons, the effects of 2-kHz sine waves were not different, so the excitation by unmodulated sine waves is not a sensitization by FluoVolt.

    DANDI:001272 holds 3 Di-8-ANEPPS neurons (three distinct cells by their images, 65 sessions), where the paper…

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Figure S1data in DANDI:001272 (assigned from its title)figs1-di8-same-as-fluovolt
    From the paper

    Experiments were performed on eight neurons using different electric field strengths tested in a random sequence ... Overall, stimulation effects were not different from those observed with FluoVolt dye

    Result

    DANDI:001272 holds 3 Di-8-ANEPPS neurons (three distinct cells by their images, 65 sessions), where the paper reports eight and the 001272 claims file's count allows no other value, so its figs1-eight-neurons part fails. On the three, under the O1(a) readings, the mean 1-AP threshold is 3.73 to 4.23 V against 4.11 to 4.39 V for 25 to 27 FluoVolt neurons of 001032, 001033 and 001035 (two-sided unpaired t p = 0.72 to 0.93), so no difference is found; the O1(b) ROI is empty in every 001272 session. The next lower voltage tested is 0.5 and 0.2 V below the thresholds of 2_20240806 and 4_20240806; 3_20240806's threshold (2.0 V) is its lowest voltage tested, an upper bound. The three response-pattern claims of the 001272 claims file, which its figs1-effects-same-as-fluovolt also needs, are not run here.

    Deviations from the paper’s method
    • Only the neuron count and the threshold test of the 001272 claims file are run; its pattern claims (near-threshold delayed APs, shorter delay and sustained firing, sustained depolarization) are not.
    • Thresholds of the two dyes are compared in stated volts, assuming 001272 and 001032 to 001035 state voltages on the same scale.

Blocked1

  • Blocked

    Lowering solution conductivity from 16.4 to 8.4 mS/cm with sodium gluconate reversibly lowered excitation thresholds about 2-fold at all sine wave frequencies from 2 to 20 kHz.

    None of the 803 sessions of 001032 to 001035 names the low-conductivity NaGlu solution, and 001030, the only…

    Metadata insufficientResults, Decreased extracellular conductivity lowers excitation thresholds, paragraph 1; Figures 3A and 3Bdata in DANDI:001030 and 001032 to 001035 (assigned from their titles)fig3b-low-conductivity-halves-threshold
    From the paper

    Switching to the NaGlu-based solution reversibly and reproducibly decreased excitation thresholds ~2-fold across all sine wave frequencies tested

    Result

    None of the 803 sessions of 001032 to 001035 names the low-conductivity NaGlu solution, and 001030, the only NaGlu dandiset of the paper found, holds 2-s ramped 2-kHz waves in four cells and no NaCl sessions. No 250-ms NaGlu sessions at 2 to 20 kHz were found in any dandiset of the paper's list that was read (001030 to 001035, 001271, 001272); 001031, 001273 and 001274 hold other stimuli by their titles.

    Deviations from the paper’s method
    • The paper does not say which dandiset holds Figures 3A and 3B; the claims file's assignment (001030, 001032 to 001035) is from titles, and none of them holds the data. Blocked as metadata_insufficient (the data cannot be located from the paper or the archive), since the checker does not allow data_missing for a claim with data elsewhere.

Not tested in a notebook 4

4 other

Blocked4

  • Blocked

    Membrane charging by 2-us pulses is fast; pooled over 19 experiments, charging and discharging time constants averaged 0.7 and 0.91 us at the cathodic pole and 0.65 and 0.8 us at the anodic pole, so membranes charge fully within each sine wave cycle up to 100 to 200 kHz.

    Not attempted in this run. The criterion follows the claims file of DANDI:001273, whose fits (charging and…

    OtherResults, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4D and 4Edata in DANDI:001273 (assigned from its title)fig4-pooled-time-constants
    From the paper

    The time constants pooled together for all cells averaged 0.7 ± 0.08 (charging) and 0.91 ± 0.08 (discharging) μs for the cathodic cell pole and 0.65 ± 0.05 and 0.8 ± 0.07 μs for the anodic pole, respectively (mean ± SEM, n = 19)

    Result

    Not attempted in this run. The criterion follows the claims file of DANDI:001273, whose fits (charging and discharging time constants of the cathodic and anodic poles from 2-us strobe images of 512 x 512 pixels, 160 frames per file, 181 files, 10.6 GB) are an analysis of their own; after the other claims the run's five hours left no time to build and check it. Streaming is not the limit (a 59-MB file of 001273 read in 2.3 s).

  • Blocked

    Aligning elongated cells with the field doubled the time constants; the maximum optical TMP and the time constants did not differ between the cathode- and anode-facing poles; and discharging was slower than charging except in elongated cells aligned with the field.

    Not attempted in this run. The criterion follows the claims file of DANDI:001273, whose fits (charging and…

    OtherResults, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4D and 4Edata in DANDI:001273 (assigned from its title)fig4-orientation-and-poles
    From the paper

    Δ F max did not differ at the cathodic and anodic cell poles, indicating the lack of rectification of the applied electric field ... Aligning elongated cells with the electric field doubled the time constants ... discharging time constants were always larger than the charging ones in the same cell ( p < 0.001, paired t test)

    Reported statistics
    • elongated cells, parallel against perpendicular: paired t test, p < 0.001
    • elongated parallel against random cells: unpaired t test, p < 0.01
    • discharging against charging tau: paired t test, p < 0.001
    Result

    Not attempted in this run. The criterion follows the claims file of DANDI:001273, whose fits (charging and discharging time constants of the cathodic and anodic poles from 2-us strobe images of 512 x 512 pixels, 160 frames per file, 181 files, 10.6 GB) are an analysis of their own; after the other claims the run's five hours left no time to build and check it. Streaming is not the limit (a 59-MB file of 001273 read in 2.3 s).

  • Blocked

    FluoVolt sensitivity to 2-kHz sine waves (11.8% per 1 kV/cm) was 42% of that to 2-us pulses (28% per 1 kV/cm) and smaller in every ROI, with sine waves polarizing the two poles more asymmetrically than pulses.

    Not attempted in this run. The criterion follows five claims of the claims file of DANDI:001274 (per-ROI field…

    OtherResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraphs 2 to 5; Figures 5, 6B to 6D and S3data in DANDI:001274 (assigned from its title)fig6-sine-less-than-pulse
    From the paper

    All numbers were invariably smaller than those measured for the same ROIs with the pulse ( Figure 6D ). The electric field sensitivity averaged across all ROIs in all the cells was 11.8% ± 1.7% per 1 kV/cm, just 42% of the value for the 2-μs pulses

    Result

    Not attempted in this run. The criterion follows five claims of the claims file of DANDI:001274 (per-ROI field sensitivity to 2-us pulses and to sine waves from strobe images, 232 files, 25.0 GB), an analysis of its own that the run's time did not allow after the other claims. Streaming is not the limit (a 116-MB file read in 4.0 s).

  • Blocked

    The 2-kHz AP threshold of 57.7 V/cm times the sine wave sensitivity gives a 0.68% emission change, about 6.8 mV, so the threshold depolarization is 5 to 15 mV, as with intracellular current injection.

    Depends on fig6-sine-less-than-pulse, which is blocked (other), so it is blocked for the same reason.

    OtherResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, last paragraphdata in DANDI:001032 to 001035 for the threshold and DANDI:001274 for the sensitivity (assigned from their titles)threshold-depolarization-estimate
    From the paper

    This threshold corresponds to a 0.68% ± 0.11% FluoVolt emission change (11.8 × 57.7/1,000) ... a 0.68% emission change corresponds to a 6.8-mV depolarization at the AP threshold

    Result

    Depends on fig6-sine-less-than-pulse, which is blocked (other), so it is blocked for the same reason. Its other input, the mean 2-kHz unmodulated 1-AP threshold, is 74.1 V/cm under the first reading here (fig2d-modulated-thresholds-higher), against the paper's 57.7.

Attempt semenov-2025-03, on DANDI:001272 version 0.250805.1358

Di-8-ANEPPS controls on DANDI:001272, with a FluoVolt reference group 7 Open in Colab

Reproduced2

  • Reproduced

    With Di-8-ANEPPS, APs appear as brief reductions of emission, opposite in sign to FluoVolt.

    Answer to questions/001272.yaml on the O3 width.

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Methods, Recording of the optical APs and data analyses; Figure S1 legendfigs1-aps-as-emission-decrease
    From the paper

    APs were identified by the reduction instead of the increase of emission

    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged. Under all 12 readings (O1 ROI a, b and the whole frame, O2 F0 a and b, O3 height a and b), every neuron with APs had more APs on the inverted trace than on the trace as recorded in all of its sessions with APs. The trace as recorded yields 2 APs, in subject 2 under the four Otsu-ROI readings with the 5% height (none with the 2-ms bound). The largest brief deflection during the stimulus, as recorded, is negative in 57 of 65 sessions.

    Deviations from the paper’s method
    • The soma outline is not deposited. The claims file's Otsu ROI (O1 a) keeps one bright membrane edge of the soma (26 to 48 of 256 pixels), and eroding it by 2 pixels (O1 b) leaves nothing in all 65 files, so reading (b) equals (a). The whole deposited 16 x 16 frame, a crop around the soma, is run as a third ROI reading.
    • Frame 0 (1.7 to 15.7 times the median brightness) and the last frame are left out of every trace, a standard choice.
  • Reproduced

    In Di-8-ANEPPS neurons, increasing the field strength reduced the delay to the first AP and induced sustained firing.

    Under the adopted readings (whole frame, height (b) read as prominence) the first-AP latency correlates…

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Figure S1verifier disagreed at firstrests on an assumptionfigs1-stronger-field-shorter-delay-sustained-firing
    From the paper

    Increasing the electric field strength reduced the delay and induced sustained firing

    Result

    Under the adopted readings (whole frame, height (b) read as prominence) the first-AP latency correlates negatively with field in all 3 neurons (Spearman rho -0.63, -0.03 and -0.50, p 0.007, 0.88 and 0.058) and all 3 show sustained firing (in 5, 11 and 10 sessions). The criterion is met under 10 of 12 readings and all 6 with height (b), with the height as prominence and as the dF value alike, and with the earlier 2-ms width bound. With the height as the dF value more sessions show sustained firing (8, 22 and 11 under whole/a/b), part of it noise on a raised baseline (null test). Most single correlations are not significant (rho from -0.94 to 0.50 over readings). It fails under the 5% height with the whole-frame ROI, where few Di-8-ANEPPS APs reach 5%.

    Deviations from the paper’s method
    • Assumed the AP height read as prominence, as for figs1-near-threshold-delayed-aps; the outcome is the same with the height as the dF value.
    • Assumed O3 height reading (b), 5 SD of the trace before onset, for Di-8-ANEPPS. The 5% level is the Methods' selection level for FluoVolt APs, and the paper says Di-8-ANEPPS has a lower voltage sensitivity (Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye); the Di-8-ANEPPS APs measured here have a median height of 3.7 to 6.7% over the readings.

Partially reproduced1

  • Partially reproduced

    Overall, the effects of 2-kHz sine waves in Di-8-ANEPPS neurons did not differ from those with FluoVolt, so the excitation by unmodulated sine waves is not a sensitization by FluoVolt.

    Under unit reading (i) the t test finds no difference between the Di-8-ANEPPS (n = 2 or 3, mean 108 to 152…

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Discussion, paragraph 2verifier disagreed at firstrests on an assumptionquestion to the readeruses data from outside the datasetfigs1-effects-same-as-fluovolt
    From the paper

    Overall, stimulation effects were not different from those observed with FluoVolt dye

    Result

    Under unit reading (i) the t test finds no difference between the Di-8-ANEPPS (n = 2 or 3, mean 108 to 152 V/cm) and FluoVolt (n = 20 to 27, mean 140 to 178 V/cm) 1-AP thresholds under all 12 readings (p 0.27 to 0.98; difference -43 to 1 V/cm, 95% intervals as wide as -156 to 124 V/cm), nor with the height as prominence (p 0.15 to 0.64). Under reading (ii) the Di-8-ANEPPS thresholds are higher under 9 of 12 readings (p 0.002 to 0.017; 8 of 12 as prominence, 12 of 12 with the earlier 2-ms width bound). The response pattern holds only in part (figs1-near-threshold-delayed-aps not reproduced, figs1-stronger-field-shorter-delay-sustained-firing reproduced, figs1-culminates-in-sustained-depolarization not reproduced), so the criterion's condition for reproduced is not met; its condition for not reproduced, a threshold difference, is not met under the adopted unit reading either. The FluoVolt mean, about 150 V/cm, is far above the paper's 57.7 V/cm (reported, not judged); the one-sample tests of the Di-8-ANEPPS thresholds against 57.7 V/cm give p 0.14 to 0.36 with n = 2 or 3. With n = 2 or 3 and intervals this wide, the absence of a difference carries little information. The criterion gives no outcome for a pattern that fails with no threshold difference; this is asked of a reader in questions/001272.yaml. The change of figs1-near-threshold-delayed-aps to not reproduced in verification round 3 leaves this outcome as it is, as the pattern fails either way.

    Deviations from the paper’s method
    • Assumed unit reading (i), the volts as the files state them times the files' 36 V/cm per volt in both groups. The 001032 to 001035 files call their volts peak-to-peak, and the 001272 files say only amplitude. In DANDI 001271, FluoVolt recorded in 2024 with the same wording as 001272, the 2-kHz thresholds (mean 3.70 V, n = 20) and those of 001032 to 001035 (4.20 V, n = 27) do not differ (p = 0.29). This gives no evidence against one scale but does not show the scales are equal, and the files say the delivered amplitude is smaller by a calibration that is not deposited. Reading (ii), FluoVolt volts halved, is shown.

Not reproduced4

  • Not reproduced

    The Di-8-ANEPPS control experiments were made on eight neurons, at field strengths tested in a random sequence.

    The dataset holds 3 neurons (subjects 2_20240806, 3_20240806 and 4_20240806, with 20, 29 and 16 sessions)…

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Figure S1figs1-eight-neurons
    From the paper

    Experiments were performed on eight neurons using different electric field strengths tested in a random sequence

    Result

    The dataset holds 3 neurons (subjects 2_20240806, 3_20240806 and 4_20240806, with 20, 29 and 16 sessions), against 8 in the paper, and no frame stack is deposited twice. The fields were tested in mixed order in all three (rises and falls in each); subjects 2 and 4 mostly escalate.

  • Not reproduced

    Near threshold, 2-kHz sine waves elicited one or a few delayed APs in Di-8-ANEPPS neurons.

    Under the adopted readings (whole frame, F0 (a), height (b) read as prominence, O5 (a)) every neuron fires a…

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Figure S1verifier disagreed at firstrests on an assumptionfigs1-near-threshold-delayed-aps
    From the paper

    Stimulation near the threshold elicited one or a few delayed APs

    Result

    Under the adopted readings (whole frame, F0 (a), height (b) read as prominence, O5 (a)) every neuron fires a median of 1 AP at its threshold field, but only subject 4 has its first AP 100 ms or more after onset (137 ms); subjects 3 and 2 fire at 63 and 6 ms. So 1 of 3 neurons meets the criterion, where more than half are needed. Each neuron's near-threshold AP is later than its APs at higher fields (2.7, 8.3 and 21.8 ms). With the height as prominence the criterion is met in 20 of 48 reading combinations, 0 of 24 under O5 (a) and 20 of 24 under O5 (b). With the height as the dF value it is met in 19 of 48 (6 of 24 under O5 (a), 13 of 24 under O5 (b); 12 of 48 with the earlier 2-ms width bound); under whole/a/b subject 2 then fires 2 APs at threshold, the first at 108 ms, and subject 4 one at 201 ms, so 2 of 3 neurons meet it. One or a few APs near threshold hold in all three neurons, later than at higher fields, and a delay of 100 ms or more in one or two of the three, depending on the height reading. The questions on "delayed" and on the AP height are for the paper's authors (findings). Changed from partially reproduced after verification round 3. The criterion is one test per neuron, which needs the median near-threshold session to have 1 to 3 APs and its first AP delayed, and it is met when more than half of the neurons pass it; 1 of 3 passes under the adopted readings, under O4 (a) and (b) alike. Partially reproduced described the two halves of that test, which the criterion does not judge apart. Under O5 (b), "delayed" relative to the neuron's own higher fields, every neuron's near-threshold AP is later, so the outcome rests on the reading of "delayed" (assumed true).

    Deviations from the paper’s method
    • Assumed the AP height read as prominence for Di-8-ANEPPS, after verification round 1. With the height as the dF value, the whole frame and height (b), the detector finds 46 peaks after the stimulus in 23 of 65 sessions (0.91 per 100 ms, against 2.09 during it), as bleaching raises the inverted trace; with prominence it finds 1 (0.02 against 1.43). The value reading is shown beside it.
    • Assumed O5 (a), a first AP at least 100 ms after onset, as the paper's sense of "delayed". The paper quantifies the near-threshold delay only for FluoVolt (100 to 200 ms, Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1) and says the Di-8-ANEPPS effects did not differ (Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye). Under O5 (b), relative to the neuron's own higher fields, the outcome depends on the ROI and height readings (met in 13 of 24 combinations with the height as the dF value, 20 of 24 as prominence).
  • Not reproduced

    In Di-8-ANEPPS neurons, the strongest fields replaced firing with sustained depolarization (excitation followed by inhibition of firing).

    Answer to questions/001272.yaml on the O3 width.

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Figure S1 legendfigs1-culminates-in-sustained-depolarization
    From the paper

    induced sustained firing that culminated in sustained depolarization

    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged. At most 1 of the 3 neurons meets the criterion under any of the 24 reading and level combinations (more than half needed), as with 2 ms, and also with the AP height taken as prominence. Subjects 2 and 4 were stimulated up to 234 V/cm only, close to their thresholds (108 to 180 and 108 to 205 V/cm), and never reach sustained depolarization. Subject 3, stimulated up to 504 V/cm, meets it only with the whole frame and the 5% height (with the height as prominence also with the Otsu ROI and level (b)); with the whole frame and height (b) it still fires 6 APs in the last 100 ms at 504 V/cm, with a late inverted dF of 2.9 to 3.3% at 396 to 504 V/cm against 1.4 to 2.4% at most lower fields (with the height as prominence 1 AP remains in the last 100 ms at 504 V/cm). Bleaching raises the inverted trace late in the AP-free sessions by 1.36 to 1.57%, which the O6 levels do not remove; with each neuron's AP-free late mean subtracted, a variant added after verification round 1, no neuron meets the criterion under any combination.

    Deviations from the paper’s method
    • A neuron counts when most of its highest-field sessions show sustained depolarization, a standard choice; every highest field here has one session except subject 2 (2) and subject 4 (6).
  • Not reproduced

    Di-8-ANEPPS traces were noisier than FluoVolt traces, as the dye has a lower voltage sensitivity.

    Changed from partially reproduced after verification round 1, since the criterion requires both measures and…

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1uses data from outside the datasetfigs1-noisier-than-fluovolt
    From the paper

    Compared to FluoVolt recordings, the traces were expectedly noisier (Di-8-ANEPSS has a lower voltage sensitivity)

    Result

    Changed from partially reproduced after verification round 1, since the criterion requires both measures and is met under none of the 12 readings, with either width bound and with the height as the dF value or as prominence. By the SD before the onset (reading b), the direct measure of noise, which does not depend on AP detection, the Di-8-ANEPPS traces are less noisy (whole frame 0.55 against 0.88%, p below 0.001; Otsu ROI 1.24 against 1.57 or 3.05%). By the signal to noise ratio (reading a) the Di-8-ANEPPS median is lower than the FluoVolt median under 10 of 12 readings with the height as the value and 6 of 12 as prominence (whole frame 7.0 to 9.7 against 12.7 to 12.9, t test p 0.001 to 0.14), because its median AP height is about half (3.7 to 6.7% against 10.1 to 14.5%; the FluoVolt value is near the paper's 11.3%). 3 Di-8-ANEPPS neurons against 20 to 27 FluoVolt neurons.

    Deviations from the paper’s method
    • The FluoVolt group is the 2-kHz unmodulated 250-ms sessions of DANDI 001032, 001033 and 001035 (209 sessions, 28 neurons). DANDI 001034 is a byte-identical copy of 001032 (80 of 80 such sessions) and is counted once. DANDI 001030 holds only 2-s ramped waves in sodium gluconate and has no session the criterion admits.

FluoVolt findings on the paper's other deposits 7 Open in Colab

Reproduced2

  • Reproduced

    In the same neuron at the same field strength, pure sine waves triggered more APs than modulated ones, and the threshold was typically lower for unmodulated signals.

    Answer to questions/001272.yaml on the O3 width.

    Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 2; Figures 2A to 2Cdata in DANDI:001032 to 001035 (assigned from their titles)fig2c-pure-more-aps
    From the paper

    the threshold was typically lower for unmodulated signals ( Figures 2A - 2C ). At the same field strengths, pure sine waves triggered a larger number of APs

    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged. Under all 12 readings, with either bound, unmodulated waves evoke more APs than modulated ones at the same neuron, carrier and field in more of the 52 pairs than the reverse (22 to 47 against 0 to 12; paired t test p from below 0.0001 to 0.022), and the unmodulated threshold is lower in more neurons than the reverse (9 to 14 against 0 to 2). The same holds under all 12 readings with the height read as prominence.

  • Reproduced

    1 uM tetrodotoxin abolished both the APs and the sustained depolarization caused by intense unmodulated 2-kHz sine waves, while the vehicle did not.

    Answer to questions/001272.yaml on the O3 width.

    Results, Tetrodotoxin blocks sustained depolarization, paragraph 1; Figure S2 legendverifier disagreed at firstrests on an assumptionquestion to the readerdata in DANDI:001271 (assigned from its title)figs2-ttx-blocks-depolarization
    From the paper

    the inhibition of sodium channels with 1 μM tetrodotoxin not only abolished the APs but also fully blocked the sustained depolarization

    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged. Under the 4 whole-frame readings and the Otsu-ROI readings with height (b), with either bound, APs present before TTX are absent after in every TTX neuron of DANDI 001271 (whole/a/b, 20 to 94 APs before, 0 after, at 4 to 6 matched fields in all 6), and every vehicle neuron with matched fields keeps firing (13 of 13 under the whole frame). Under the Otsu ROI with the 5% height, 1 to 4 TTX neurons keep detections after TTX, the readings that also detect 20 APs in 5 sham sessions. The criterion's second part is conditional (sustained depolarization present before is absent after). Sustained depolarization before TTX is found in only 1 of 6 TTX neurons (14_20240731), and is absent after; the other 5 do not test that part, and no TTX neuron has a late mean dF above 5% before. After TTX the late dF is -0.38 to -0.70% in every TTX neuron, against 0.12 to 3.28% before. So the APs part is tested in 6 neurons and the sustained-depolarization part in 1. With the height read as prominence, a variant, 3 or 4 of the 6 TTX neurons keep detections after TTX under the whole frame (1 to 6 each under whole/a/b); that reading detects 1 or 2 peaks in the 5 sham sessions, where the value reading detects none. The record uses prominence for fig3c-sustained-firing-2s and the value reading here; under prominence this claim would fail. A reader is asked in questions/001272.yaml whether the criterion should require sustained depolarization before TTX, which the conditional criterion lets pass when it is absent.

    Deviations from the paper’s method
    • Nothing in the files marks when the vehicle was added; for vehicle neurons the largest gap between consecutive sessions (0.6 to 10.8 min) is taken as the change. One vehicle neuron (17_20240801) has no field in common across the gap and is not counted.
    • The ROI is the whole frame, as assumed for fig2-modulated-locks-to-beats.

Partially reproduced2

  • Partially reproduced

    With 20-Hz modulation, firing above threshold locked to the beats, one AP near the peak of each of the five beats and at most two per beat (ten in all), and modulated sine waves triggered no sustained firing or sustained depolarization.

    Answer to questions/001272.yaml on the O3 width.

    Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 1; Figures 2A and 2Brests on an assumptionquestion to the readerdata in DANDI:001032 to 001035 (assigned from their titles)fig2-modulated-locks-to-beats
    From the paper

    single APs emerged near the peak of each beat, so the firing rate equaled the modulation rate ... the maximum number of APs evoked by five beats was limited to ten. Unlike pure sine waves, modulated stimuli did not trigger sustained firing or sustained depolarization

    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged, but the criterion is now met under fewer readings and fails under the adopted whole frame for a different reason. Locking holds under every reading. In most sessions with 5 or more APs most fall 12.5 to 37.5 ms into the 50-ms beat (whole frame 22 of 25 or 23 of 26 sessions; 66 to 100% of all APs there over readings, 89 to 91% under the whole frame), and the whole-frame phase histogram peaks 20 to 35 ms into the beat while that of unmodulated sessions is flat. The criterion is met under 4 of 12 readings, the Otsu-ROI readings with height (b) (8 of 12 with 2 ms). Under the Otsu ROI with the 5% height 10 to 20 modulated sessions have more than 10 APs (up to 17), readings that detect 20 APs in 5 sham sessions. Under the 4 whole-frame readings one modulated session (001032 neuron 10_1, 2 kHz, 8 V) has 13 APs, against 17 in the neuron's unmodulated session at that field, and no modulated session shows sustained depolarization. With 2 ms the whole-frame readings failed instead on sustained depolarization by O6 level (a) in one session, with no session over 10 APs, and so do they with the height read as prominence (at most 9 APs; met under 4 of 12 readings). The null test of the detector finds 0.09 to 0.10 peaks per 100 ms after the stimulus under the whole frame, against 1.77 to 1.83 during it, and under the Otsu ROI with the 5% height 1.04 to 1.06 (ROI a, against 2.44 to 2.47 during) and 2.12 to 2.14 (ROI b, against 3.33 to 3.38). The statement's "no sustained firing" is not tested by the criterion; the O6 sustained-firing rule is met by beat-locked firing (45 or 46 of 84 modulated sessions under the whole frame), and a reader is asked in questions/001272.yaml whether the criterion should test it.

    Deviations from the paper’s method
    • Assumed the whole deposited frame as the soma ROI where the ROI readings disagree (here and in fig3c-sustained-firing-2s and figs2-ttx-blocks-depolarization). The Methods measure "the emission over the entire cell soma"; the deposited 16 x 16 frames are a crop around the soma, the claims file's Otsu ROI keeps one membrane edge only, and with the 5% height it detects 5 APs in the 5 sham sessions of DANDI 001271, where the whole frame detects none.
    • The beat peak is taken 25 ms into each 50-ms beat, as the criterion says; the files do not store the stimulus waveform.
  • Partially reproduced

    In the low-conductivity solution, a 2-s unmodulated 2-kHz sine wave ramped over 250 ms evoked firing for its whole duration, rising with field until replaced by a firing block with sustained depolarization.

    Answer to questions/001272.yaml on the O3 width.

    Results, Decreased extracellular conductivity lowers excitation thresholds, paragraph 3; Figure 3Cverifier disagreed at firstrests on an assumptiondata in DANDI:001030 (assigned from its title)fig3c-sustained-firing-2s
    From the paper

    we observed sustained firing for the entire duration of the sine wave ( Figure 3C ). The rate of firing increased with the electric field strength until it was replaced by a firing block and sustained depolarization

    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged. The pattern is present in neuron c7 of DANDI 001030. Under the whole frame with the AP height taken as prominence it fires through the 2-s wave at 1.45 to 2.0 V (75 to 91 APs, 8 to 10 in the last 250 ms), and at 2.3 V fires 19 APs, none in the last 250 ms, with a late dF of 6.0% against 5.4% or less at lower fields; it meets all three parts. Under the whole frame c7's 1.0-V session is the only session without APs, so the two bleaching corrections subtract the same trace from c7's sessions and are one check for c7, not two. With the height as the dF value, 9 detections in the last 250 ms at 2.3 V count as firing and c7 fails. A null test on 001030, added after verification round 2, does not decide between the height readings. Under the whole frame neither detects a peak in the 25 ms before the onset, and after the stimulus, where the trace is back near baseline, the value reading detects none and prominence 0 to 7 (up to 0.24 per 100 ms, against 1.85 to 2.60 during the stimulus). The 9 late detections at 2.3 V have prominences of 1.9 to 4.4%, below the 4.43% threshold, but the session's earlier detections have prominences of 1.3 to 19.1% (median 4.0%), so prominence does not set the late ones apart by size. The outcome rests on the prominence reading, supported by the figure of the traces (a flat plateau at 2.3 V) and the verifier's synthetic test, and not confirmed by a null test. No reading has more than 1 of the 4 neurons meeting the criterion (at most 2 with 2 ms, when c8 also met it under the shared correction), and no Otsu-ROI reading has any. c5 and c6 were stimulated up to 2.0 and 1.45 V only and keep firing; two c5 files end at 1,913 ms, before the stimulus ends.

    Deviations from the paper’s method
    • The Methods subtract "a trace without APs" for bleaching without saying which. Two readings are run, each neuron's own lowest-field session when it has no AP (only c7's has none), and the dataset's one AP-free 2-s session subtracted from all others.
    • The criterion does not say whether the pattern is judged per neuron or in the representative neuron of Figure 3C. It is judged per neuron here, and the outcome is partial as it holds in 1 or 2 of 4.
    • Assumed the AP height read as prominence, as a depolarized baseline makes noise peaks pass a height measured as the dF value; the verifier's synthetic test (a 5.5% plateau with 0.5% noise gives 6 false APs with the value, 0 with prominence) shows the mechanism.
    • The O6 window is the last 250 ms of the stimulus, as this claims file's criterion gives it.

Not reproduced3

  • Not reproduced

    Unmodulated 250-ms sine waves at 2 and 20 kHz excited every neuron tested, with APs 100 to 200 ms after onset near threshold, firing rate rising to a ceiling of 60 to 90 Hz, and an excitation block with sustained depolarization at the highest fields.

    Answer to questions/001272.yaml on the O3 width.

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Figures 1A to 1C and insetquestion to the readerdata in DANDI:001030 and 001032 to 001035 (assigned from their titles; the paper does not map figures to dandisets)fig1-pure-sine-excites-all
    From the paper

    Pure sine waves at 2 and even 20 kHz excited 100% of neurons ... The maximum firing rate increased linearly until reaching a ceiling of 60-90 Hz

    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged, and no reading meets the criterion with either bound, so the readings agree and the claim is not blocked. Measured values are those of the first reading (a/a/a), with the fraction for 2 kHz (with 2 ms they were 96.4, 41.15 and 78.63). Excitation is close to the claim under the whole frame (27 of 28 neurons at 2 kHz, 15 or 16 of 17 at 20 kHz; 8 to 17 of 17 at 20 kHz over all readings). Each reading fails one of the other two parts. The median over neurons of the highest first-two-AP rate is 25 to 177 Hz (whole frame 45 to 47 Hz, below the 54-Hz bound; 21 to 61 Hz with 2 ms), and the median first-AP latency at the lowest exciting field is 15 to 77 ms (whole frame 62 to 64 ms; 66 to 79 ms with 2 ms), below the 90-ms bound. Under a/a/a and a/b/a the rate, 63 Hz, is within its bounds, and the latency, 32 and 36 ms, is not; in the null test these readings detect 1.04 to 1.06 peaks per 100 ms after the stimulus and 1.07 to 1.10 before the onset, against 2.44 to 2.47 during it, and 20 in the 5 sham sessions. At most 1 of 32 neurons shows sustained depolarization at its highest field. Split by carrier, which the criterion's median does not do, the whole-frame latency is 49 ms at 2 kHz and 112 to 124 ms at 20 kHz. Leaving out the 38 sessions of 900 frames gives whole-frame rates of 47 to 49 Hz and latencies of 56 to 59 ms, and the height read as prominence gives rates of 39 to 43 Hz and latencies of 54 to 55 ms; no reading meets the criterion in either variant.

    Deviations from the paper’s method
    • Data from DANDI 001032, 001033 and 001035, assigned to Figure 1 by the claims file from their titles; 001034 duplicates 001032 and is not used. 38 sessions have 900 frames and cover only 241 ms of the 250-ms stimulus.
    • The claims file's earlier AP width bound of 2 to 20 ms is run as a variant, to show what the reader's answer changed; it gives the same outcome.
  • Not reproduced

    Responses to 20 kHz needed about 2-fold stronger fields than at 2 kHz, and all thresholds at 20 kHz were about 2-fold higher than at 2 kHz.

    Answer to questions/001272.yaml on the O3 width.

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Results, Excitation thresholds are similar or lower, paragraph 1; Figure 2Ddata in DANDI:001032 to 001035 (assigned from their titles)fig1-20khz-needs-twice-the-field
    From the paper

    All thresholds at 20 kHz were about 2-fold higher than at 2 kHz ( p < 0.0001, two-tailed unpaired t test)

    Reported statistics
    • 20 kHz against 2 kHz, all thresholds: two-tailed unpaired t test, p < 10⁻⁴
    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged. No reading meets the criterion under (a) or (b), with either bound. The 20-kHz thresholds are higher than the 2-kHz ones (pooled p at most 1.4e-9; unmodulated groups p at most 0.003, below 0.0001 under the whole frame), but in every reading at least one ratio of means is outside 1.8 to 2.2. They range from 1.71 to 2.98 (1.88 to 2.86 with 2 ms); whole frame 2.27 to 2.39 for 1 AP and 2.41 to 2.44 for 5 APs unmodulated, 2.62 and 2.82 to 2.83 modulated. Under a/a/a the unmodulated ratios, 2.00 and 2.13, are within the range and the modulated ones, 2.77 and 2.98, are not. The modulated 20-kHz groups hold 1 to 3 neurons. Measured is the unmodulated 1-AP ratio of the first reading (2.16 with 2 ms).

    Deviations from the paper’s method
    • Thresholds use the files' nominal volts; the files say the delivered amplitude is smaller by a frequency-dependent calibration that is not deposited, which bears directly on a 20 against 2 kHz ratio.
  • Not reproduced

    Thresholds for sine waves modulated at 20 Hz were significantly higher than for pure sine waves at the same carrier, for 5 APs at 2 kHz and for 1 and 5 APs at 20 kHz, so modulation did not lower excitation thresholds.

    Answer to questions/001272.yaml on the O3 width.

    Results, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2Ddata in DANDI:001032 to 001035 (assigned from their titles)fig2d-modulated-thresholds-higher
    From the paper

    thresholds for modulated sine waves, which emulate the TI stimulus at the target, were significantly higher than those for pure sine waves at the same frequency ... p = 0.0079 ... p = 0.0142 and p = 0.0037

    Reported statistics
    • modulated against unmodulated, 2 kHz, 5 APs: two-tailed unpaired t test, p = 0.0079
    • modulated against unmodulated, 20 kHz, 1 AP: two-tailed unpaired t test, p = 0.0142
    • modulated against unmodulated, 20 kHz, 5 APs: two-tailed unpaired t test, p = 0.0037
    Result

    Answer to questions/001272.yaml on the O3 width. The claims file now takes an AP's width at half height between 1 and 20 ms, where it had 2 to 20 ms; re-run with 1 ms, the outcome is unchanged. No reading meets the criterion, with either bound, so the readings agree. Modulated thresholds are higher in every group with data, but the 2-kHz 5-AP difference is not significant under any reading (p 0.0500 to 0.93; 0.085 to 0.48 with 2 ms). Under whole/a/a and whole/b/a the other three parts hold and this p, 0.0500, is at the bound and not below it, so the outcome is close to the criterion there. The 20-kHz modulated groups hold 1 to 3 neurons (1 AP p 0.0005 to 0.87; 5 APs p 0.0096 to 0.058 where computable). The 2-kHz 1-AP threshold is not lower for modulated waves (higher, p 0.023 to 0.75).

Strobe imaging of membrane charging on DANDI:001273 2 Open in Colab

Not reproduced1

  • Not reproduced

    Membrane charging by 2-us pulses is fast; pooled over 19 experiments, charging and discharging time constants averaged 0.7 and 0.91 us at the cathodic pole and 0.65 and 0.8 us at the anodic pole, so membranes charge fully within each sine wave cycle up to 100 to 200 kHz.

    Changed from blocked after verification round 1.

    Results, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4D and 4Everifier disagreed at firstdata in DANDI:001273 (assigned from its title)fig4-pooled-time-constants
    From the paper

    The time constants pooled together for all cells averaged 0.7 ± 0.08 (charging) and 0.91 ± 0.08 (discharging) μs for the cathodic cell pole and 0.65 ± 0.05 and 0.8 ± 0.07 μs for the anodic pole, respectively (mean ± SEM, n = 19)

    Result

    Changed from blocked after verification round 1. The criterion defers to the DANDI 001273 claims file, whose header (F2) runs the fits unscaled where the debris ROI is not available, so the claim is testable; all 22 experiments are now fitted under every reading (001273-O1 ROI a and b, O2 weighting, O3 discharge amplitude). No reading gives all four mean time constants within the paper's SEMs (0 of 8; 0 of 8 also with the whole-frame scaling variant), so the readings agree. Charging means are near the paper's under some readings (cathodic 0.68 to 1.27 us against 0.7 +/- 0.08, anodic 0.64 to 0.77 us against 0.65 +/- 0.05); discharging means are higher (cathodic 1.30 to 2.35 us against 0.91 +/- 0.08, anodic 0.91 to 2.62 us against 0.8 +/- 0.07), and the SEMs over experiments (0.13 to 0.65 us) are larger than the paper's. The traces are noisy, the dF late in the pulse a median 1.97 times the SD before it (0.16 to 8.37). Of 352 unscaled fits, 58 charging and 15 discharging time constants end at a fit bound and are left out; none failed to converge. Measured values are those of the first reading (ROI a, unweighted, free discharge amplitude), in the order of the expected values. The missing debris scaling may account for the difference.

    Deviations from the paper’s method
    • Unscaled fits, as the 001273 claims file's F2 gives when the debris ROI is not available; the debris ROI is not deposited. Scaling by the whole-frame mean is shown as a variant.
    • The mean is over the 22 groups of 7 or 8 replicates of one cell, electrode orientation and amplitude in the files, where the paper reports 19 experiments, with no mapping between them.
    • Fits with a time constant within 1% of a fit bound (0.01 or 20 us) are counted as failed and left out of the mean, a standard choice; their number is reported.
    • The ROIs are rebuilt from the RATIO image under the 001273 claims file's O1 readings; the cell is the largest Otsu component of the filtered CONTROL image, a standard choice.

Blocked1

  • Blocked

    Aligning elongated cells with the field doubled the time constants; the maximum optical TMP and the time constants did not differ between the cathode- and anode-facing poles; and discharging was slower than charging except in elongated cells aligned with the field.

    The criterion needs all three of fig4-orientation-time-constants, fig4-no-pole-difference and…

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4D and 4Edata in DANDI:001273 (assigned from its title)fig4-orientation-and-poles
    From the paper

    Δ F max did not differ at the cathodic and anodic cell poles, indicating the lack of rectification of the applied electric field ... Aligning elongated cells with the electric field doubled the time constants ... discharging time constants were always larger than the charging ones in the same cell ( p < 0.001, paired t test)

    Reported statistics
    • elongated cells, parallel against perpendicular: paired t test, p < 0.001
    • elongated parallel against random cells: unpaired t test, p < 0.01
    • discharging against charging tau: paired t test, p < 0.001
    Result

    The criterion needs all three of fig4-orientation-time-constants, fig4-no-pole-difference and fig4-discharging-slower of the DANDI 001273 claims file. The orientation part needs the cell-shape groups (elongated parallel, elongated perpendicular, random), which the files do not label (they give the electrode positions only, up and bottom for 83 files, right and left for 35, not specified for 63). The other two parts were run on the unscaled fits of fig4-pooled-time-constants and are reported. No pole difference is found in |dFmax|, charging tau or discharging tau under any of the 8 readings (paired p 0.25 to 0.98, n = 15 to 21), as the claim says. Discharging tau is larger than charging tau under every reading (by 0.52 to 1.56 us) but not at p below 0.001 (p 0.0013 to 0.22) over all experiments and both poles, the 001273 criterion's reading (a); its readings (b) and (c) and the exception for elongated parallel cells need the groups.

Not tested in a notebook 3

3 other

Blocked3

  • Blocked

    Lowering solution conductivity from 16.4 to 8.4 mS/cm with sodium gluconate reversibly lowered excitation thresholds about 2-fold at all sine wave frequencies from 2 to 20 kHz.

    No deposit holds the data. The claim needs 1-AP thresholds for 250-ms unmodulated sine waves at 2 to 20 kHz in…

    OtherResults, Decreased extracellular conductivity lowers excitation thresholds, paragraph 1; Figures 3A and 3Bdata in DANDI:001030 and 001032 to 001035 (assigned from their titles)fig3b-low-conductivity-halves-threshold
    From the paper

    Switching to the NaGlu-based solution reversibly and reproducibly decreased excitation thresholds ~2-fold across all sine wave frequencies tested

    Result

    No deposit holds the data. The claim needs 1-AP thresholds for 250-ms unmodulated sine waves at 2 to 20 kHz in both NaCl and sodium gluconate solution. No file read of DANDI 001032, 001033, 001035 and 001271 mentions gluconate (0 of the 454 2- and 20-kHz files of 001032, 001033 and 001035, 0 of the 287 of 001271; the other files of these deposits are at other frequencies and were not read), 001030 holds only 2-s ramped 2-kHz waves in sodium gluconate (17 files), and 001031 holds 100-kHz bipolar pulses. The paper names no other deposit. This would be data_missing, which the registry's check does not allow for a claim marked elsewhere.

  • Blocked

    FluoVolt sensitivity to 2-kHz sine waves (11.8% per 1 kV/cm) was 42% of that to 2-us pulses (28% per 1 kV/cm) and smaller in every ROI, with sine waves polarizing the two poles more asymmetrically than pulses.

    Not attempted in this run. The criterion defers to five claims of the DANDI 001274 claims file (26 claims)…

    OtherResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraphs 2 to 5; Figures 5, 6B to 6D and S3data in DANDI:001274 (assigned from its title)fig6-sine-less-than-pulse
    From the paper

    All numbers were invariably smaller than those measured for the same ROIs with the pulse ( Figure 6D ). The electric field sensitivity averaged across all ROIs in all the cells was 11.8% ± 1.7% per 1 kV/cm, just 42% of the value for the 2-μs pulses

    Result

    Not attempted in this run. The criterion defers to five claims of the DANDI 001274 claims file (26 claims), whose measures need ROIs on 512 x 512 strobe images of nine cells, with and without scaling to a debris ROI. The data are not too large (232 files, 25 GB, which stream at about 25 MB/s). The same kind of strobe recordings in DANDI 001273 could not be fitted without the debris ROI (strobe_check.ipynb); whether the larger pulse and sine-wave signals of Figures 5 and 6 survive without it was not checked here, and the run stopped short of the nine-cell analysis.

  • Blocked

    The 2-kHz AP threshold of 57.7 V/cm times the sine wave sensitivity gives a 0.68% emission change, about 6.8 mV, so the threshold depolarization is 5 to 15 mV, as with intracellular current injection.

    Depends on fig6-sine-less-than-pulse, blocked.

    OtherResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, last paragraphverifier disagreed at firstdata in DANDI:001032 to 001035 for the threshold and DANDI:001274 for the sensitivity (assigned from their titles)threshold-depolarization-estimate
    From the paper

    This threshold corresponds to a 0.68% ± 0.11% FluoVolt emission change (11.8 × 57.7/1,000) ... a 0.68% emission change corresponds to a 6.8-mV depolarization at the AP threshold

    Result

    Depends on fig6-sine-less-than-pulse, blocked. Its first expected value, the mean unmodulated 2-kHz 1-AP threshold (57.7 +/- 3.6 V/cm), is measured in fluovolt_elsewhere.ipynb as 151.2 V/cm under the whole-frame reading and 140 to 178 V/cm over all readings, with the files' nominal volts and 36 V/cm per volt; the files say the delivered amplitude is smaller by a calibration that is not deposited.

Attempt semenov-2025-04, on DANDI:001273 version 0.250805.1356

Reproducing Semenov et al. (2025), Figure 4, from dandiset 001273 6 Open in Colab

Reproduced2

  • Reproduced

    A 2-us pulse polarizes mainly the membrane facing the electrodes, depolarized at the cathode-facing pole and hyperpolarized at the anode-facing one, while even large neurites show little or no polarization.

    Tested on the 14 experiments whose session description names the electrode axis (January 19 and March 11).

    Results, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4A to 4Crests on an assumptionfig4-polarized-poles-face-electrodes
    From the paper

    In neurons of all shapes, the electric field primarily polarized membrane portions facing the electrodes ... Unexpectedly, even large neurites showed little to no polarization and did not seem to impact the charging of cell soma

    Result

    Tested on the 14 experiments whose session description names the electrode axis (January 19 and March 11). In 13 of 14 the extreme depolarized and hyperpolarized pixels of the soma lie on opposite sides of its centroid with their separation within 45 degrees of the field axis (median angle 13.8 degrees); the exception (cell 1 of March 11) is at 48.7 degrees. With the axes swapped, 1 of 14 passes. In the 40 V experiments, 10 of 11 pass. The shape groups are not in the dataset, so the majority is taken over all experiments with an axis (O4), not per group. The polarity of the electrodes is not given, so which pole faced the cathode is not tested. With the soma mask opened by a disc of radius 8 pixels, to trim neurite stumps the threshold mask can take in, 12 of 14 pass (median angle 17.1 degrees). The neurite part is reported, not judged; the 99th percentile of the absolute RATIO change outside the soma is below that within it in 21 of 22 experiments.

    Deviations from the paper’s method
    • The ROIs are not in the dataset. The extreme pixels are taken from the RATIO image rebuilt as the Methods describe (Pulsed laser fluorescence microscopy, CONTROL, POLARIZED and RATIO images, 12 x 12 pixel low-pass filter), within the soma, defined as the connected region of the filtered CONTROL image brighter than halfway between the image median and the brightest central pixel (a standard choice; the neuron was centred in the field, Methods, Sine wave and square pulse stimulation). The centroid is that of the soma region.
    • Assumed that "Up and Bottom" in the session description is the image's vertical axis and "Right and Left" its horizontal axis. The files do not give the orientation of the camera image relative to the stage; this is the plain reading of the description.
    • The 8 January 17 experiments have "Electrode position not specified" and are left out.
  • Reproduced

    The maximum optical TMP and the charging and discharging time constants did not differ between the cathode- and anode-facing poles, indicating no rectification of the field.

    Two-sided paired t tests, cathodic against anodic, of |dFmax|, charging tau and discharging tau.

    Results, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4D and 4Efig4-no-pole-difference
    From the paper

    Δ F max did not differ at the cathodic and anodic cell poles, indicating the lack of rectification of the applied electric field. Charging and discharging time constants did not differ between the two poles either

    Result

    Two-sided paired t tests, cathodic against anodic, of |dFmax|, charging tau and discharging tau. None of the 16 unscaled readings (ROI a and b, weighting none or 1/SEM^2, discharge amplitude free or fixed, in both experiment sets) finds a difference at p < 0.05, and none of the frame-scaled variants does. Main reading (all 22 experiments, ROI a, unweighted, free amplitude) |dFmax| difference -2.36% (95% CI -6.92 to 2.21, p = 0.29, n = 15 pairs), charging tau 0.35 us (-0.48 to 1.18, p = 0.38), discharging tau -0.03 us (n = 14). The intervals are wide and, in set A, 7 to 10 of 22 experiments per reading lose a pair to a failed fit, so the test has little power. The time constants do not differ under any variant (each experiment's estimated onset, fits with tau beyond its window dropped, ROI a clipped to the soma). The amplitude does in two variants. With fits whose tau exceeds its window dropped, |dFmax| differs at p = 0.046 in 2 of 8 set A readings (n = 12). The |dF| over the last 0.5 us of the pulse, which needs no fit and keeps all 22 experiments, is larger at the anodic pole in set A (cathodic minus anodic -2.86%, p = 0.014, ROI a; -2.54%, p = 0.011, ROI b) but not in the 40 V set (p = 0.28 and 0.24); the difference grows with amplitude (-0.95% at 40 V, -14.82% and -12.23% at 100 and 130 V, ROI a), and without the 100 and 130 V runs it is -1.79% (p = 0.048). The criterion's quantity, the fitted |dFmax|, shows no difference under any of the header readings (O1 to O3); only the window variant, which drops fits, gives p = 0.046 in 2 of its 8 set A readings. The outcome follows the criterion's quantity and readings. The absence of a pole difference in amplitude is weak in set A, and depends on whether the 100 and 130 V runs belong to the paper's 19 experiments, which the dataset does not say.

    Deviations from the paper’s method
    • The test is run over the 22 experiments in the dataset (set A) and over the 15 at 40 V (set B); the paper's 19 cannot be identified.
    • Unscaled data only; the debris ROI used for scaling is not in the dataset (claims file, F2).
    • ROIs rebuilt from the RATIO image under the claims file's readings O1 (a) and (b), within the soma region described under fig4-polarized-poles-face-electrodes.
    • Fits that fail or end at a bound (tau 0.005 or 50 us, amplitude 200%) are dropped, a standard choice; the counts are printed. Fits are least squares in SciPy, not Origin 8.0.

Not reproduced1

  • Not reproduced

    Pooled over all 19 experiments, charging and discharging time constants averaged 0.7 and 0.91 us at the cathodic pole and 0.65 and 0.8 us at the anodic pole.

    Means over experiment fits, all 22 experiments, unscaled.

    Results, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4D and 4E (ALL)fig4-pooled-time-constants
    From the paper

    The time constants pooled together for all cells averaged 0.7 ± 0.08 (charging) and 0.91 ± 0.08 (discharging) μs for the cathodic cell pole and 0.65 ± 0.05 and 0.8 ± 0.07 μs for the anodic pole, respectively (mean ± SEM, n = 19)

    Result

    Means over experiment fits, all 22 experiments, unscaled. Under no reading of O1 to O3, in either experiment set, are all four within the paper's SEMs. In set A the cathodic charging means are 0.65 to 1.01 us (0.7 plus or minus 0.08), the cathodic discharging means are 1.37 to 4.20 us (0.91 plus or minus 0.08), the anodic charging means are 0.62 to 2.28 us (0.65 plus or minus 0.05), and the anodic discharging means are 1.32 to 2.22 us (0.8 plus or minus 0.07). The measured values are from reading ROI a, unweighted, free amplitude. The medians over experiments are lower (cathodic discharging 1.02 to 1.46 us). The frame-scaled variant has no row within tolerance either. The per-experiment fits are noisy (charging tau from 0.02 to 4.3 us at the cathodic pole), and 2 to 6 of 22 fits per pole and reading are dropped. Three variants give the same outcome, with no reading in either set within the SEMs. With each experiment's estimated onset the set A cathodic discharging means are 1.43 to 3.77 us; with fits dropped whose tau exceeds the time it is fitted over (2 us charging, 5 us discharging) they are 1.55 to 1.92 us, and the cathodic charging means fall to 0.41 to 0.50 us; with ROI a clipped to the soma they are 1.36 to 1.58 us.

    Deviations from the paper’s method
    • The ROIs and the debris ROI are not in the dataset. The polarized ROIs are rebuilt from the RATIO image (O1 a and b), and the traces are unscaled (F2). The paper scaled to the debris ROI to remove flash-to-flash laser fluctuations, which this attempt could not do; the whole-frame scaling shown as a variant is not the paper's.
    • 22 experiments in the dataset against the paper's 19; set A uses all 22, set B the 15 at 40 V.
    • Dim frames (below 70% of the file's median frame mean, mostly the first image acquired) are dropped, a standard choice; 204 of 28,000 frames.
    • The time base is the Methods' (frame 20 is the pulse onset, 50 ns per frame); the onset estimated from the data has median 19.9 frames (18.0 to 21.0), and the fits are repeated with it as a variant.
    • Fits are kept up to tau 50 us, a standard choice; values beyond the fitted window are poorly constrained, so a variant drops them.

Blocked3

  • Blocked

    In elongated neurons, charging was about 2-fold faster with the field orthogonal to the long axis; aligning elongated cells with the field doubled the time constants compared with the same cells perpendicular to it or with randomly shaped cells.

    The groups of Figure 4D and 4E (elongated parallel n = 3, elongated perpendicular n = 6, random n = 10) are…

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4A, 4D and 4Efig4-orientation-time-constants
    From the paper

    Aligning elongated cells with the electric field doubled the time constants, as compared to either the same cells oriented perpendicular to the field ( p < 0.001, paired t test) or to randomly shaped cells ( p < 0.01, unpaired t test)

    Reported statistics
    • elongated cells, parallel against perpendicular (text): paired t test, p < 0.001
    • elongated cells, between the orthogonal orientations (Figure 4D and 4E legend): unpaired two-tailed t test, p < 0.01 (n = parallel n = 3, perpendicular n = 6)
    • elongated parallel against random cells: unpaired t test, p < 0.01 (n = parallel n = 3, random n = 10)
    Result

    The groups of Figure 4D and 4E (elongated parallel n = 3, elongated perpendicular n = 6, random n = 10) are not in the dataset, and the paper judged shape and orientation by eye (O4). The four January 19 cells were imaged on both electrode axes, but which axis was parallel to each cell's long axis is not recorded. Their charging tau per axis is printed for reference only.

  • Blocked

    Discharging time constants were larger than charging ones in the same cell, except in elongated cells aligned with the field.

    The criterion needs the elongated parallel group for the exception (O4), which the dataset does not label.

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legend; Figures 4D and 4Efig4-discharging-slower
    From the paper

    discharging time constants were always larger than the charging ones in the same cell ( p < 0.001, paired t test), with the exception of elongated cells aligned with the field

    Reported statistics
    • discharging against charging tau (text): paired t test, p < 0.001
    • discharging against charging tau, per group and pole (Figure 4D and 4E legend, hash sign): paired two-tailed t test, p < 0.01
    Result

    The criterion needs the elongated parallel group for the exception (O4), which the dataset does not label. Reading (a), all experiments and both poles, is shown for each reading of the header. Its result depends on the reading. In set A, discharging minus charging tau averages -0.09 to 1.25 us, with p from 0.0016 to 0.90; none reaches the paper's p < 0.001.

  • Blocked

    Membranes exceed 95% of full charge in under 3 us, even in the largest neurons and with the least efficient alignment with the field, so each cycle of a sine wave fully polarizes the membrane even at 100 to 200 kHz.

    Reading (a) needs the elongated parallel group, which the dataset does not label (O4).

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, the paragraph after the Figure 4 legendfig4-full-charge-within-3us
    From the paper

    It will take <3 μs to exceed 95% of the full charge, even in the largest neurons and with the least efficient cell alignment with the field

    Result

    Reading (a) needs the elongated parallel group, which the dataset does not label (O4). Reading (b) fails under every reading of the header (3 to 5 experiments per pole and reading have 3 tau above 3 us; the largest cathodic charging tau is 4.29 us under ROI a, unweighted), so it cannot stand in for (a). It fails too with charging fits whose tau exceeds the 2-us pulse dropped (largest tau 1.64 to 1.97 us, 4 to 6 pole fits with 3 tau above 3 us). The claim also depends on fig4-pooled-time-constants, which was not reproduced.

Semenov et al. (2025), Figure 3C, from dandiset 001030 (data elsewhere) 1 Open in Colab

Partially reproduced1

  • Partially reproduced

    In the low-conductivity solution, a 2-s unmodulated 2-kHz sine wave ramped over 250 ms evoked firing for its whole duration, rising with field until replaced by a firing block with sustained depolarization.

    DANDI:001030 version 0.240520.1924, 17 sessions of four cells (c5 to c8) at 1.0 to 2.3 V.

    Results, Decreased extracellular conductivity lowers excitation thresholds, paragraph 3; Figure 3Cverifier disagreed at firstrests on an assumptiondata in DANDI:001030 (assigned from its title)fig3c-sustained-firing-2s
    From the paper

    we observed sustained firing for the entire duration of the sine wave ( Figure 3C ). The rate of firing increased with the electric field strength until it was replaced by a firing block and sustained depolarization

    Result

    DANDI:001030 version 0.240520.1924, 17 sessions of four cells (c5 to c8) at 1.0 to 2.3 V. Judged per cell, bleach-corrected. In all four cells, under both AP readings, an intermediate field fires in the last 250 ms of the stimulus and the AP count after the ramp rises with field. Cell c7 meets the whole criterion under both readings; at 2.3 V it has no AP after the ramp and a corrected mean dF of 6.66%. Cells c5 and c8 stop firing at their highest field (1 and 0 APs after the ramp under reading (a), 0 under (b)) but their mean dF there is 3.48% and 3.63%, below the 5% level. Cell c6 keeps firing at its highest field, 1.45 V (32 APs after the ramp). So the criterion holds in 1 of 4 cells, and the firing part in all 4. With the first run's detector it holds in none (reading (a) counts 197 noise peaks on the c7 plateau, reading (b) one, at 1,707 ms), which also gives a partial result; without the bleaching correction it holds in no cell (c7 at 2.3 V has a mean dF of 3.30%).

    Deviations from the paper’s method
    • Data elsewhere, in DANDI:001030, as the claims file assigns from the dandiset's title.
    • F is the mean over the whole 16 x 16 frame. At this resolution the soma the Methods name ("emission intensity over the entire cell soma") cannot be outlined.
    • The bleaching trace is the only session without APs during the stimulus under both readings (c7 at 1.0 V), used for every cell (Methods, "corrected for bleaching by subtracting a trace without APs"). Uncorrected results are shown too.
    • The first 20 frames (6.4 ms) of each file are dropped, a standard choice. The first frame is 2.6 to 7.6 times brighter than the rest, and the next ones recover from it.
    • The criterion does not say how cells are combined. Each cell's field series is judged on its own, as Figure 3C shows one cell ("Sustained firing and depolarization in a neuron", Figure 3 legend). Assumed that the claim is reproduced when the criterion holds in most cells, partially reproduced when it holds in at least one cell or its firing parts hold in most, and not reproduced otherwise. The Results present the neuron of Figure 3C as what was observed ("we observed sustained firing for the entire duration of the sine wave"), so a typical cell should show it, which a single cell does not establish. The outcome rests on this rule. Judged on any one cell the claim would be reproduced (c7); judged on most cells it would not.
    • AP detection runs on a 1-ms running mean of the trace; a reading (a) peak must stand 5% dF above its surroundings, and peaks of both readings must be at least 5 ms apart. These are standard choices (APs last about 10 ms, Methods). The first run used no smoothing and a prominence of 2.5%, which counted noise on a depolarized plateau as APs; it is shown as a variant.

Semenov et al. (2025), Figure S1, from dandiset 001272 (data elsewhere) 1 Open in Colab

Not reproduced1

  • Not reproduced

    With Di-8-ANEPPS instead of FluoVolt, in eight neurons, near-threshold stimulation elicited one or a few delayed APs and stronger fields induced sustained firing ending in sustained depolarization, as with FluoVolt.

    DANDI:001272 version 0.250805.1358, 65 sessions of three neurons (the paper reports eight).

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Figure S1question to the readerdata in DANDI:001272 (assigned from its title)figs1-di8-anepps-control
    From the paper

    Stimulation near the threshold elicited one or a few delayed APs. Increasing the electric field strength reduced the delay and induced sustained firing that culminated in sustained depolarization

    Result

    DANDI:001272 version 0.250805.1358, 65 sessions of three neurons (the paper reports eight). The criterion holds under none of the three AP readings. In no neuron does the highest field end in depolarization at the criterion's 5% level; the largest mean inverted dF over the last 100 ms of any session is 3.2%. Under reading (c), 5 SD of the pre-stimulus trace, every neuron fires and first-AP latency falls with field in all 3; under reading (a) the 5% level finds APs only in neuron 3_20240806 (4 sessions), and under reading (b) in no neuron. In 19 of 52 sessions with APs under reading (c) the first AP comes within 5 ms of the onset, which may be an onset artefact; without those, latency falls in 2 of 3. No variant changes the outcome. With the first run's detector, without the first 5 ms, or with the depolarization level at 5 SD of each neuron's pre-stimulus trace (2.2 to 2.5%), the highest field ends in depolarization in at most one neuron under any reading. The Di-8-ANEPPS signals are smaller than the FluoVolt signals the 5% level comes from, so the failure may lie in that level and not in the data; whether the level suits this dye is asked of a reader (questions/001273.yaml).

    Deviations from the paper’s method
    • Data elsewhere, in DANDI:001272, as the claims file assigns from the dandiset's title. Three neurons where the paper reports eight.
    • F is the mean over the whole 16 x 16 frame (the soma cannot be outlined), inverted, with the first 20 frames dropped (standard choices).
    • The stimulus timing (50 ms before, 250 ms during) is from the Methods ("The standard imaging protocol started 50 ms before sine wave stimulation and continued for 250 ms during"); the files do not give it.
    • The criterion does not fix how "latency falls with field" or the window of "ends in depolarization" are judged. Latency falls when the Spearman correlation of field and first-AP latency over a neuron's sessions with APs is negative. A neuron ends in depolarization when its highest-field sessions have no APs in the last 100 ms of the stimulus and mean dF above 5% there, the window the claims file uses for 250-ms stimuli (fig2-modulated-locks-to-beats). Both are standard choices; no window gives the 5% level, as no session reaches it over its last 100 ms.
    • AP detection runs on a 1-ms running mean, and a peak of reading (a) or (c) must stand above its surroundings by the detection level (standard choices, as for fig3c-sustained-firing-2s). The first run's detector is a variant.

Semenov et al. (2025): a metadata survey of the paper's other dandisets 4 Open in Colab

Blocked4

  • Blocked

    Unmodulated 250-ms sine waves at 2 and 20 kHz excited every neuron tested, with APs 100 to 200 ms after onset near threshold, firing rate rising to a ceiling of 60 to 90 Hz, and an excitation block with sustained depolarization at the highest fields.

    Data elsewhere (DANDI:001032 to 001035).

    OtherResults, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Figures 1A to 1C and insetquestion to the readerdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles; the paper does not map figures to dandisets)fig1-pure-sine-excites-all
    From the paper

    Pure sine waves at 2 and even 20 kHz excited 100% of neurons ... The maximum firing rate increased linearly until reaching a ceiling of 60-90 Hz

    Result

    Data elsewhere (DANDI:001032 to 001035). Not tested; the author run ran out of time after the Figure 4 analysis. A metadata survey of those dandisets (survey_other_dandisets.ipynb) finds 16 x 16 pixel image stacks at 3,086.4 frames/s with the stimulus given only in free text, and 001034 holding the same 178 image arrays as 001032, byte for byte, with the same session descriptions under other subject ids.

  • Blocked

    Lowering solution conductivity from 16.4 to 8.4 mS/cm with sodium gluconate reversibly lowered excitation thresholds about 2-fold at all sine wave frequencies from 2 to 20 kHz.

    Data elsewhere, but not found there. The metadata survey (survey_other_dandisets.ipynb) finds every session…

    OtherResults, Decreased extracellular conductivity lowers excitation thresholds, paragraph 1; Figures 3A and 3Bdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig3b-low-conductivity-halves-threshold
    From the paper

    Switching to the NaGlu-based solution reversibly and reproducibly decreased excitation thresholds ~2-fold across all sine wave frequencies tested

    Result

    Data elsewhere, but not found there. The metadata survey (survey_other_dandisets.ipynb) finds every session description of DANDI:001032 to 001035 (803 files) naming the 140 mM NaCl solution; the only sodium gluconate sessions are the 17 of 001030, all with a 2-s ramped 2-kHz stimulus. The NaGlu thresholds of Figure 3B do not appear to be deposited. Not tested further for lack of time; the claim also depends on fig1-pure-sine-excites-all.

  • Blocked

    1 uM tetrodotoxin abolished both the APs and the sustained depolarization caused by intense unmodulated 2-kHz sine waves.

    Data elsewhere (DANDI:001271, 287 sessions of 20 subject ids, 71 described as recorded in the presence of…

    OtherResults, Tetrodotoxin blocks sustained depolarization, paragraph 1; Figure S2question to the readerdata in DANDI:001271 (assigned from its title)figs2-ttx-blocks-depolarization
    From the paper

    the inhibition of sodium channels with 1 μM tetrodotoxin not only abolished the APs but also fully blocked the sustained depolarization

    Result

    Data elsewhere (DANDI:001271, 287 sessions of 20 subject ids, 71 described as recorded in the presence of tetrodotoxin and 216 without it; survey_other_dandisets.ipynb). Not tested for lack of time.

  • Blocked

    FluoVolt sensitivity to 2-us pulses averaged 28% plus or minus 2.5% per 1 kV/cm (15% to 47%), and to 2-kHz sine waves 11.8% plus or minus 1.7% per 1 kV/cm, 42% of the pulse value, smaller in every ROI.

    Data elsewhere (DANDI:001274, 232 files, 25.0 GB of strobe images; survey_other_dandisets.ipynb).

    OtherResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraphs 4 and 5; Figures 6B to 6Ddata in DANDI:001274 (assigned from its title); the 2-us pulse recordings of these nine cells may be in 001274 or in this dandisetfig6-sine-less-than-pulse
    From the paper

    All numbers were invariably smaller than those measured for the same ROIs with the pulse ( Figure 6D ). The electric field sensitivity averaged across all ROIs in all the cells was 11.8% ± 1.7% per 1 kV/cm, just 42% of the value for the 2-μs pulses

    Result

    Data elsewhere (DANDI:001274, 232 files, 25.0 GB of strobe images; survey_other_dandisets.ipynb). Not started for lack of time in the author run, as for fig1-pure-sine-excites-all; its criterion also takes its readings from the claims file for 001274. The nine cells' 2-us, 257 V/cm pulse recordings are not in this dandiset. Its files were recorded on 2024-01-17, 01-19 and 03-11, all name the three-electrode array of Figure 4, and 001274's files date from May and August 2024 (reproduce_semenov_2025.ipynb, data check).

Not tested in a notebook 5

5 other

Blocked5

  • Blocked

    Thresholds for 1 and 5 APs at 20 kHz were about 2-fold those at 2 kHz, and thresholds for sine waves modulated at 20 Hz were significantly higher than for pure sine waves for 5 APs at 2 kHz and for 1 and 5 APs at 20 kHz.

    Data elsewhere (DANDI:001032 to 001035).

    OtherResults, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2Ddata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig2d-modulated-thresholds-higher
    From the paper

    All thresholds at 20 kHz were about 2-fold higher than at 2 kHz ( p < 0.0001, two-tailed unpaired t test) ... thresholds for modulated sine waves, which emulate the TI stimulus at the target, were significantly higher than those for pure sine waves at the same frequency

    Reported statistics
    • 20 kHz against 2 kHz, all thresholds: two-tailed unpaired t test, p < 10⁻⁴
    • modulated against unmodulated, 2 kHz, 5 APs: two-tailed unpaired t test, p = 0.0079
    • modulated against unmodulated, 20 kHz, 1 AP: two-tailed unpaired t test, p = 0.0142
    • modulated against unmodulated, 20 kHz, 5 APs: two-tailed unpaired t test, p = 0.0037
    Result

    Data elsewhere (DANDI:001032 to 001035). Not tested for lack of time, as for fig1-pure-sine-excites-all, on which it depends.

  • Blocked

    With 20-Hz modulation, firing above threshold locked to the beats, one AP near the peak of each of the five beats and at most two per beat (ten in all), and modulated sine waves triggered no sustained firing or sustained depolarization.

    Data elsewhere (DANDI:001032 to 001034, the "spindle" sessions).

    OtherResults, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 1; Figures 2A and 2Bquestion to the readerdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig2-modulated-locks-to-beats
    From the paper

    single APs emerged near the peak of each beat, so the firing rate equaled the modulation rate ... the maximum number of APs evoked by five beats was limited to ten. Unlike pure sine waves, modulated stimuli did not trigger sustained firing or sustained depolarization

    Result

    Data elsewhere (DANDI:001032 to 001034, the "spindle" sessions). Not tested for lack of time, as for fig1-pure-sine-excites-all, on which it depends.

  • Blocked

    In the same neuron at the same field strength, pure sine waves triggered more APs than modulated ones.

    Data elsewhere (DANDI:001032 to 001034).

    OtherResults, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 2; Figure 2Cdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig2c-pure-more-aps
    From the paper

    At the same field strengths, pure sine waves triggered a larger number of APs

    Result

    Data elsewhere (DANDI:001032 to 001034). Not tested for lack of time, as for fig1-pure-sine-excites-all, on which it depends.

  • Blocked

    In single cells, sine waves polarized the two poles more asymmetrically than a 2-us pulse (ROI 2 up to 90% smaller than ROI 1 with sine waves against 30% with the pulse in Figure 5; 40% against 20% in Figure S3), with carrier oscillations antiphasic in the two ROIs on a gradual whole-cell depolarization.

    Data elsewhere (DANDI:001274), as for fig6-sine-less-than-pulse.

    OtherResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraphs 2 and 3; Figures 5B to 5D and S3data in DANDI:001274 (assigned from its title)fig5-sine-asymmetry
    From the paper

    Unexpectedly, in this cell, the oscillations in ROI 2 were up to 90% smaller than those in ROI 1 (compared to just 30% smaller when the same cell was polarized with the 2-μs pulse)

    Result

    Data elsewhere (DANDI:001274), as for fig6-sine-less-than-pulse. Not started for lack of time.

  • Blocked

    The 2-kHz AP threshold of 57.7 V/cm times the sine wave sensitivity gives a 0.68% emission change, about 6.8 mV, so the threshold depolarization is 5 to 15 mV, as with intracellular current injection.

    Depends on fig6-sine-less-than-pulse and fig2d-modulated-thresholds-higher, neither tested for lack of time.

    OtherResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 6data in DANDI:001032 to 001035 for the threshold and DANDI:001274 for the sensitivity (assigned from their titles)threshold-depolarization-estimate
    From the paper

    This threshold corresponds to a 0.68% ± 0.11% FluoVolt emission change (11.8 × 57.7/1,000) ... a 0.68% emission change corresponds to a 6.8-mV depolarization at the AP threshold

    Result

    Depends on fig6-sine-less-than-pulse and fig2d-modulated-thresholds-higher, neither tested for lack of time.

Attempt semenov-2025-05, on DANDI:001274 version 0.250805.1401

Reproducing Semenov et al. (2025) from dandiset 001274 and the paper's other dandisets 12 Open in Colab

Reproduced2

  • Reproduced

    In the same neuron at the same field strength, pure sine waves trigger more APs than modulated ones.

    In 52 pairs from 12 neurons (same neuron, carrier and generator voltage), the unmodulated sine wave gave more…

    Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 2; Figure 2Cdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig2c-pure-more-aps
    From the paper

    At the same field strengths, pure sine waves triggered a larger number of APs

    Result

    In 52 pairs from 12 neurons (same neuron, carrier and generator voltage), the unmodulated sine wave gave more APs in 47, fewer in none and as many in 5, a mean of 3.70 more (reading a, paired t p = 7.3e-10); reading (b) 46 and 1, p = 2.5e-09; the bright-pixel trace 47 or 44 and 0 or 2. By carrier, 39 of 44 pairs at 2 kHz and 8 of 8 at 20 kHz (reading a).

    Deviations from the paper’s method
    • Counts repeated at one field are averaged per pair, a standard choice.
  • Reproduced

    In the low-conductivity solution, a 2-s unmodulated 2-kHz sine wave ramped up over 250 ms evoked sustained firing for the whole stimulus; firing rate rose with field strength until replaced by a firing block with sustained depolarization, which developed before the end of the ramp.

    Tested on neuron c7 of 001030, the only neuron with a trace without APs (1.0 V), which the Methods' bleaching…

    Results, Decreased extracellular conductivity lowers excitation thresholds, paragraph 3; Figure 3Cverifier disagreed at firstrests on an assumptiondata in DANDI:001030 (assigned from its title)fig3c-sustained-firing-2s
    From the paper

    we observed sustained firing for the entire duration of the sine wave ( Figure 3C ). The rate of firing increased with the electric field strength until it was replaced by a firing block and sustained depolarization. The block had already developed before the end of the 250-ms ramp-up period

    Result

    Tested on neuron c7 of 001030, the only neuron with a trace without APs (1.0 V), which the Methods' bleaching correction needs. (i) APs occur in the last 250 ms at 52, 61 and 72 V/cm (8 to 10 under both readings). (ii) The AP count rises with field, from 0 at 36 V/cm to 89 (a) or 90 (b) at 61 V/cm, then 88 and 13 (a) or 80 and 8 (b). (iii) At the highest field, 83 V/cm, the mean dF over 0.25 to 2 s is 6.7% and the APs stop within the ramp; reading (a) finds 5 peaks after 250 ms (0.34 to 1.74 s) and reading (b) one (1.68 s). Measured on this trace (notebook section 11), noise alone gives as many detections over 0.25 to 2 s as were found (residual SD 0.94%, against 0.89% before the stimulus; mirrored trace 6 (a) and 7 (b); running median plus Gaussian noise a mean of 7.8 (a) and 5.1 (b), 5 or more in 91% of draws under (a), 1 or more in 99% under (b); shuffled residual 8.4 and 4.6), and about 1.1 (a) and 0.7 (b) per 250-ms window against the 8 to 10 APs of part (i). Read as no more detections after 250 ms than the trace's noise gives, (iii) holds. Taken literally, no APs after 250 ms, it fails under both readings, as it would on any plateau above 5% with this noise; the outcome was not_reproduced until the third verification round. The test rests on c7 alone. The other three neurons, corrected with the same trace, reach no block, which the criterion does not count against the claim.

    Deviations from the paper’s method
    • Assumption. Part (iii) is read as no more detections after 250 ms than the noise of the bleaching-corrected trace gives, measured on the trace itself, as the claims file's AP readings have no allowance for false detections on a depolarized plateau and the Methods give no detection rule. The outcome rests on it.
    • The field is 36 V/cm times the one-polarity voltage that 001030 gives.
    • The other neurons are corrected with c7's AP-free trace, as they have none of their own.
    • Two recordings of neuron c5 have 6,000 frames, which end before the 2-s stimulus does.

Partially reproduced1

  • Partially reproduced

    Thresholds for sine waves modulated at 20 Hz were significantly higher than for pure sine waves of the same carrier, for 5 APs at 2 kHz and for 1 and 5 APs at 20 kHz.

    The modulated mean is higher in all three pairs under both readings.

    Results, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2Ddata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig2d-modulated-thresholds-higher
    From the paper

    thresholds for modulated sine waves, which emulate the TI stimulus at the target, were significantly higher than those for pure sine waves at the same frequency (for 2 kHz, 5 APs ... p = 0.0079; for 20 kHz, 1 and 5 APs, respectively ... p = 0.0142 and p = 0.0037)

    Reported statistics
    • modulated against unmodulated, 2 kHz, 5 APs: two-tailed unpaired t test, p = 0.0079
    • modulated against unmodulated, 20 kHz, 1 AP: two-tailed unpaired t test, p = 0.0142
    • modulated against unmodulated, 20 kHz, 5 APs: two-tailed unpaired t test, p = 0.0037
    Result

    The modulated mean is higher in all three pairs under both readings. Under reading (a) two pairs reach p < 0.05 (20 kHz 1 AP p = 0.021, 20 kHz 5 APs p = 0.017; 2 kHz 5 APs p = 0.069); under reading (b) the same two (p = 0.021 and 0.012; 2 kHz 5 APs p = 0.155). The 20-kHz modulated groups have 3 neurons for 1 AP and 2 for 5 APs. The 2-kHz 1-AP pair, for which the paper reports no difference, gives unpaired p = 0.059 (a) and 0.045 (b), and paired p below 0.001 on 12 neurons. Paired tests on the three pairs give p from 0.12 to 0.29.

    Deviations from the paper’s method
    • As in fig2d-20khz-twofold-threshold.

Not reproduced9

  • Not reproduced

    Unmodulated 250-ms sine waves at 2 kHz and at 20 kHz excited every neuron tested, never as an on-off response.

    At 2 kHz 27 of 28 neurons (96%) fired at least one AP under both AP readings, at 20 kHz 15 of 17 (88%), below…

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Figure 1A to 1Cverifier disagreed at firstquestion to the readerdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles; the paper does not map figures to dandisets)fig1-pure-sine-excites-all
    From the paper

    Pure sine waves at 2 and even 20 kHz excited 100% of neurons. It was never an "on-off" response

    Result

    At 2 kHz 27 of 28 neurons (96%) fired at least one AP under both AP readings, at 20 kHz 15 of 17 (88%), below the criterion's 90% at each frequency (measured gives the 20-kHz value). The bright-pixel trace gives the same, except 28 of 28 at 2 kHz under reading (b). The two neurons not excited at 20 kHz (001033/sub-7-2, 001035/sub-10-4) were tested up to 288 and 324 V/cm and fired in other sessions (26 and 11 APs). Their 20-kHz traces show no AP of 5%; sub-10-4 has 8 upticks of 2.5% at 324 V/cm on a falling trace (4 in all its pre-stimulus windows), which may be small APs that no reading counts; with it the fraction would be 16 of 17 (94%). Neither neuron is dimmer than the others (mean pre-stimulus images at the 78th and 74th percentiles of all recordings). The statement's "never as an on-off response" is not tested by the criterion. Neurons are pooled over 001032, 001033 and 001035.

    Deviations from the paper’s method
    • The paper does not say which neurons or dandisets form Figure 1; all neurons tested with unmodulated 2- or 20-kHz sine waves in 001032, 001033 and 001035 are pooled.
    • F is the mean of the whole 16 x 16 frame (assumption; Methods, "The emission intensity over the entire cell soma (F)", but the files have no soma outline). It gives first APs of median 11.4% dF against the Methods' typical 11.3%. The brighter half of the frame is run as a variant and gives the same outcome.
    • AP peaks closer than 8 ms are merged, the AP duration of the Methods ("8 +- 0.7 ms duration"). Assumption: reading (a) also asks a prominence of 5% dF and a half-width of at least 1 ms (Methods: APs are "brief emission upticks" that "lasted about 10 ms"). Without them noise on a depolarized plateau counts as APs (about 18 per 250 ms on a synthetic 6% plateau with the data's noise, against 1.2 with them); 99% of the first APs of the data have a prominence above 8.6% and a half-width above 1.6 ms. The first version used a 2.5% prominence and no width. The first frame of every recording, a camera artifact, is left out of F0.
  • Not reproduced

    Near threshold, isolated APs appear 100 to 200 ms after the sine wave onset, and stronger fields shorten this delay and evoke sustained firing.

    The median first-AP latency of the near-threshold sessions is 64 ms (reading a, IQR 37 to 128, n = 42…

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Figure 1A to 1Cverifier disagreed at firstdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig1-onset-delay
    From the paper

    at near-threshold electric field strengths, isolated APs emerged with a delay of 100-200 ms after the sine wave onset ... Increasing the field strength reduced this delay and evoked sustained firing

    Result

    The median first-AP latency of the near-threshold sessions is 64 ms (reading a, IQR 37 to 128, n = 42 neuron-carrier pairs) and 67 ms (reading b), below 90 to 220 ms. By carrier it is 49 ms at 2 kHz (n = 27) and 124 ms (a) or 101 ms (b) at 20 kHz (n = 15). With only thresholds that have a lower-field session without APs it is 67 ms (n = 27). The second part holds; the latency falls with field (Spearman rho below 0) in 38 of 38 (a) and 39 of 39 (b) pairs with three or more fields with APs. The criterion needs both parts. 7 of 50 near-threshold sessions have a first AP within 20 ms; their traces show AP-shaped events, not stimulus artifacts (2.6 and 2.9 ms at 180 and 153 V/cm; of the other five, at 10 to 16 ms, three are the first of 4 regular APs, their lowest tested field being already above threshold, and two are single APs). The outcome depends on pooling 001032, 001033 and 001035, as the claims file's where does; the 001035 neurons alone give a median of 101 ms, inside 90 to 220 ms, and 001032 and 001033 give 50 and 58 ms.

    Deviations from the paper’s method
    • Neuron-carrier pairs are the units for both parts (the criterion says per neuron and frequency); sessions repeated at one field are averaged, a standard choice.
    • Soma ROI and AP detection as in fig1-pure-sine-excites-all.
  • Not reproduced

    The maximum firing rate increases linearly with field strength until it reaches a ceiling of 60 to 90 Hz.

    The median ceiling over 29 neurons is 39.1 Hz under AP reading (a) (IQR 28.8 to 60.5, range 16.1 to 93.5) and…

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Figure 1 insetverifier disagreed at firstrests on an assumptiondata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig1-max-rate-ceiling
    From the paper

    The maximum firing rate increased linearly until reaching a ceiling of 60-90 Hz

    Result

    The median ceiling over 29 neurons is 39.1 Hz under AP reading (a) (IQR 28.8 to 60.5, range 16.1 to 93.5) and 42.9 Hz under reading (b) (n = 31), both below 54 to 99 Hz; the bright-pixel trace gives 41.7 (a) and 61.7 Hz (b), the last the noisiest reading (1.18 false APs per 250 ms before stimuli). The rate rises with field before the ceiling in 32 of 32 neuron-carrier pairs (median slope 0.66 Hz per V/cm). The traces of the 35 sessions that set the ceilings are shown with the APs of both readings; 5 reach 79 to 94 Hz under both. The first version of reading (a) gave 59.9 Hz by counting plateau noise, at a rate near 80 Hz on synthetic traces; the revised reading (a) finds synthetic AP trains of 40 to 100 Hz at their rate. Three neurons never fired two APs in one unmodulated session and have no rate.

    Deviations from the paper’s method
    • Assumption. Reading (a) asks a 5% prominence and a 1-ms half-width (as in fig1-pure-sine-excites-all), so that noise on a depolarized plateau is not counted. The outcome rests on it under reading (a); reading (b), as the claims file gives it, yields the same outcome.
    • The detection cannot see rates above 125 Hz (8-ms merge, Methods' AP duration).
  • Not reproduced

    At the highest field strengths, APs coalesce into low-amplitude oscillations on a continuous depolarization, which can flatten and leave the membrane depolarized for the rest of the sine wave (an excitation block).

    The highest-field unmodulated session has a last-100-ms mean dF above 5% and above the near-threshold session…

    Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1; Figure 1A to 1Cdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig1-excitation-block
    From the paper

    At the highest field strengths, multiple APs coalesced into low-amplitude oscillations on top of a continuous depolarization. These oscillations could flatten after several cycles, leaving the membrane depolarized for the rest of the sine wave

    Result

    The highest-field unmodulated session has a last-100-ms mean dF above 5% and above the near-threshold session in 3 of 42 neuron-carrier pairs under both AP readings (3 of 42 and 3 of 43 with the bright-pixel trace), against more than half. The second-half variant also gives 3. The highest-field last-100-ms dF has a median of 1.3% (range -0.7 to 9.8). The highest field tested was a median 1.36 times the near-threshold field, and 11 of 370 unmodulated sessions have a last-100-ms dF above 5%, so most neurons may not have been driven far enough above threshold in the deposited sessions. The traces are not corrected for bleaching; the near-threshold sessions end at a median of -0.2%.

    Deviations from the paper’s method
    • Soma ROI as in fig1-pure-sine-excites-all. Sessions repeated at one field are averaged.
  • Not reproduced

    All excitation thresholds at 20 kHz were about twice those at 2 kHz, for modulated and unmodulated sine waves and for 1 and 5 APs.

    Every 20-kHz threshold group is higher than the 2-kHz one with p below 0.0001 under both test readings (per…

    Results, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves than those for modulated sine waves, paragraph 1; Figure 2Dverifier disagreed at firstdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig2d-20khz-twofold-threshold
    From the paper

    All thresholds at 20 kHz were about 2-fold higher than at 2 kHz ( p < 0.0001, two-tailed unpaired t test)

    Reported statistics
    • two-tailed unpaired t test, p < 10⁻⁴ (n = n individual neurons per group (numbers in Figure 2D only))
    Result

    Every 20-kHz threshold group is higher than the 2-kHz one with p below 0.0001 under both test readings (per group at most 2e-05, pooled 3e-24), but the ratios of mean thresholds (1 AP unmodulated, 1 AP modulated, 5 APs unmodulated, 5 APs modulated) are 2.27, 2.62, 2.37 and 2.82 under AP reading (a) and 2.29, 2.63, 2.28 and 2.82 under (b), all above 1.8 to 2.2; the criterion asks every ratio within it. The modulated 20-kHz groups have 2 or 3 neurons (all in 001033). The ratio does not depend on the field reading. The descriptions say the generator voltages overstate the amplitude by frequency-dependent factors not deposited. No such factor can rescue the claim; a 20-kHz factor relative to the 2-kHz one scales the four ratios alike, and they differ among themselves by a factor of 1.24, more than the 1.22 that the band 1.8 to 2.2 allows (the factor would need to be at least 0.794 and at most 0.779 under reading a, 0.791 and 0.779 under b).

    Deviations from the paper’s method
    • Neurons of 001032, 001033 and 001035 pooled; the paper does not say which form Figure 2D.
    • The field per session is 36 V/cm times half the generator's peak-to-peak voltage, from the session descriptions, without frequency calibration (not in the dandisets).
  • Not reproduced

    The AP threshold for unmodulated 2-kHz sine waves was 57.7 plus or minus 3.6 V/cm.

    The mean 1-AP threshold for unmodulated 2-kHz sine waves is 75.6 +- 6.2 V/cm (n = 27, reading a) and 74.8 +…

    Results, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 6; Figure 2Ddata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)threshold-2khz-unmodulated
    From the paper

    the AP threshold of 57.7 ± 3.6 V/cm for unmodulated 2-kHz sine waves ( Figure 2D )

    Result

    The mean 1-AP threshold for unmodulated 2-kHz sine waves is 75.6 +- 6.2 V/cm (n = 27, reading a) and 74.8 +- 5.9 (reading b) with the field as 36 V/cm times half the peak-to-peak voltage, and 151.2 and 149.6 V/cm with the whole of it; none is within 57.7 +- 3.6. By dandiset it is 92.2 (001032, n = 10), 76.6 (001033, n = 7) and 58.3 V/cm (001035, n = 10). With only thresholds bracketed by a lower-field session without APs, 88.0 V/cm (n = 16). The half reading fits the paper's numbers: 63 and 81 V/cm are 3.5 and 4.5 Vpp under it (2 and 7 sessions) and 1.75 and 2.25 Vpp under the full reading (no session). The generator voltage overstates the amplitude by a frequency-dependent factor that is not deposited; a 2-kHz factor of 0.76 would give 57.7 V/cm, and the only measured factors in the paper's dandisets (2-us pulses, 001273, another electrode array) are 0.62 to 0.79. The miss may come from the calibration. The outcome also depends on pooling the three dandisets, as the claims file's where does; 001035 alone gives 58.3 V/cm, inside 57.7 +- 3.6. 001035 has no modulated sessions, so Figure 2D cannot come from it alone, and which neurons the paper used cannot be settled.

    Deviations from the paper’s method
    • The field conversion is the dandisets' (36 V/cm per volt) with two readings of the voltage; both give the same outcome. No frequency calibration is applied, as the factors are not in the dandisets.
  • Not reproduced

    With 20-Hz modulation, firing above threshold is locked to the beats, one AP near the peak of each of the five beats and at most two per beat (ten in all), and modulated sine waves trigger no sustained firing or sustained depolarization.

    Firing locks to the beats; of the APs in the 22 modulated sessions with 5 APs or more, 0.96 (a) and 0.98 (b)…

    Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 1; Figures 2A and 2Bverifier disagreed at firstquestion to the readerdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig2-modulated-locks-to-beats
    From the paper

    single APs emerged near the peak of each beat, so the firing rate equaled the modulation rate ... the maximum number of APs evoked by five beats was limited to ten. Unlike pure sine waves, modulated stimuli did not trigger sustained firing or sustained depolarization

    Result

    Firing locks to the beats; of the APs in the 22 modulated sessions with 5 APs or more, 0.96 (a) and 0.98 (b) fall 12.5 to 37.5 ms into a beat, against 0.04 of the APs pooled over all modulated sessions with the beats shifted by 25 ms, so (ii) holds. (i) holds under both readings (at most 8 and 6 APs). (iii) fails under both: one session (001032/sub-2-1, 198 V/cm) ends with a last-100-ms dF of 5.9%, above its near-threshold modulated session (-0.2% at 144 V/cm), so it meets the block test. The criterion asks all three parts.

    Deviations from the paper’s method
    • The beats are counted from the stimulus onset at 50 ms, with the envelope at zero there (the claims file's reading of the beat); the data support it, as the shifted beats show.
    • Part (ii) is read on the APs pooled over the sessions with 5 APs or more; per session, 21 of 22 sessions have 80% or more in the window under both readings.
  • Not reproduced

    With Di-8-ANEPPS instead of FluoVolt, in eight neurons, stimulation near threshold elicited one or a few delayed APs and stronger fields induced sustained firing ending in sustained depolarization, as with FluoVolt.

    001272 holds 3 neurons, where the paper used eight.

    Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye, paragraph 1; Figure S1question to the readerdata in DANDI:001272 (assigned from its title)figs1-di8-anepps-control
    From the paper

    Stimulation near the threshold elicited one or a few delayed APs. Increasing the electric field strength reduced the delay and induced sustained firing that culminated in sustained depolarization

    Result

    001272 holds 3 neurons, where the paper used eight. The readings disagree on excitation (3 of 3 neurons under reading a at 5% and under both 5-SD readings, 1 of 3 under reading b at 5%), but under every reading no neuron meets the block test at its highest field (0 of 3; inverted last-100-ms dF 0.7%, 3.3% and 1.6%), so the claim fails under all of them for the neurons deposited and the disagreement does not decide the outcome. Latency falls with field in 1 of 2 neurons with three fields with APs under reading (a), and 2 of 3 under the 5-SD readings. Whether the five neurons not deposited would change this cannot be known.

    Deviations from the paper’s method
    • Only 3 of the paper's 8 neurons are in the dandiset.
  • Not reproduced

    1 uM tetrodotoxin abolished both the APs and the sustained depolarization caused by intense unmodulated 2-kHz sine waves.

    In all 6 neurons recorded in tetrodotoxin (3.6 to 11 min after the normal-solution session at the same field)…

    Results, Tetrodotoxin blocks sustained depolarization, paragraph 1; Figure S2verifier disagreed at firstquestion to the readerdata in DANDI:001271 (assigned from its title)figs2-ttx-blocks-depolarization
    From the paper

    the inhibition of sodium channels with 1 μM tetrodotoxin not only abolished the APs but also fully blocked the sustained depolarization

    Result

    In all 6 neurons recorded in tetrodotoxin (3.6 to 11 min after the normal-solution session at the same field), APs present before are absent under reading (a); under reading (b) 5 of 6, as (b) finds 5% rises in 15 of 17 tetrodotoxin sessions of one neuron. The last-100-ms dF in tetrodotoxin is at most 0.4% in every session. Only 1 of the 6 neurons had a last-100-ms dF above 5% before tetrodotoxin (5.4%, falling to -0.7%), and no session of the 14 neurons never put in tetrodotoxin did (0 of 171), so the criterion, which asks the depolarization block of every tetrodotoxin neuron, fails in 5 of 6. The vehicle neuron of Figure S2 is not identified in the files; the neurons never put in tetrodotoxin stand in for it.

    Deviations from the paper’s method
    • The compared field is the highest recorded both before and in tetrodotoxin, with the latest normal session and the first tetrodotoxin session at it; the paper says "about 5 min after".
    • No neuron is labelled as the vehicle control of Figure S2; all normal-solution sessions carry the same "vehicle control" text.

Not tested in a notebook 14

14 metadata insufficient

Blocked14

  • Blocked

    Replacing NaCl with sodium gluconate, lowering conductivity from 16.4 to 8.4 mS/cm, reversibly lowered excitation thresholds about 2-fold at all sine wave frequencies from 2 to 20 kHz.

    No session of 001032, 001033 or 001035 is described as recorded in the sodium gluconate solution; every…

    Metadata insufficientResults, Decreased extracellular conductivity lowers excitation thresholds, paragraph 1; Figures 3A and 3Bdata in DANDI:001032, 001033, 001034 and 001035 (assigned from their titles)fig3b-low-conductivity-halves-threshold
    From the paper

    Switching to the NaGlu-based solution reversibly and reproducibly decreased excitation thresholds ~2-fold across all sine wave frequencies tested

    Result

    No session of 001032, 001033 or 001035 is described as recorded in the sodium gluconate solution; every description gives the standard NaCl solution. 001030 is in sodium gluconate but holds only 2-s ramped stimuli. The NaCl and NaGlu sessions of Figures 3A and 3B, if deposited, cannot be told apart. Nor do the thresholds show a hidden switch: of 47 neuron-carrier pairs with two or more ascending voltage series with APs, none has a series whose threshold drops to 0.6 or less of the series before and after it.

  • Blocked

    Elongated neurons aligned with the field have about twice the charging and discharging time constants of the same cells perpendicular to it, or of randomly shaped cells.

    001273 holds raw strobe stacks only (181 files, 13 subjects).

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, paragraph 3; Figures 4A, 4D and 4Edata in DANDI:001273 (assigned from its title)fig4-orientation-time-constants
    From the paper

    Aligning elongated cells with the electric field doubled the time constants, as compared to either the same cells oriented perpendicular to the field ( p < 0.001, paired t test) or to randomly shaped cells ( p < 0.01, unpaired t test)

    Reported statistics
    • elongated cells, parallel against perpendicular: paired t test, p < 0.001
    • elongated parallel cells against random cells: unpaired t test, p < 0.01
    Result

    001273 holds raw strobe stacks only (181 files, 13 subjects). The ROIs over the most de- and hyperpolarized regions are not deposited (claims file O1), no file says which cell is elongated or random, and the field direction is in the descriptions of 118 of 181 files only (up-bottom or right-left). The parallel, perpendicular and random groups cannot be formed.

  • Blocked

    The maximum optical TMP and the charging and discharging time constants did not differ between the cathode- and anode-facing poles, indicating no rectification of the field.

    Depends on fig4-orientation-time-constants; the paper's ROIs are not in 001273, and the 19 experiments cannot…

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, paragraph 3; Figures 4D and 4Edata in DANDI:001273 (assigned from its title)fig4-no-pole-difference
    From the paper

    Δ F max did not differ at the cathodic and anodic cell poles, indicating the lack of rectification of the applied electric field. Charging and discharging time constants did not differ between the two poles either

    Result

    Depends on fig4-orientation-time-constants; the paper's ROIs are not in 001273, and the 19 experiments cannot be matched to its 13 subjects.

  • Blocked

    Discharging time constants were larger than charging ones in the same cell, except in elongated cells aligned with the field.

    Depends on fig4-orientation-time-constants (no ROIs, no shape groups in 001273).

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, paragraph 3; Figures 4D and 4Edata in DANDI:001273 (assigned from its title)fig4-discharging-slower
    From the paper

    discharging time constants were always larger than the charging ones in the same cell ( p < 0.001, paired t test), with the exception of elongated cells aligned with the field

    Reported statistics
    • paired t test, p < 0.001
    Result

    Depends on fig4-orientation-time-constants (no ROIs, no shape groups in 001273).

  • Blocked

    Pooled over all 19 experiments, the charging and discharging time constants were 0.7 and 0.91 us at the cathodic pole and 0.65 and 0.8 us at the anodic pole, so membranes exceed 95% of full charge within 3 us.

    Depends on fig4-orientation-time-constants; no ROIs in 001273, and its 13 subjects cannot be matched to the 19…

    Metadata insufficientResults, Kinetics of membrane charging by pulsed electric fields, paragraph 3; Figures 4D and 4E (ALL)data in DANDI:001273 (assigned from its title)fig4-pooled-time-constants
    From the paper

    The time constants pooled together for all cells averaged 0.7 ± 0.08 (charging) and 0.91 ± 0.08 (discharging) μs for the cathodic cell pole and 0.65 ± 0.05 and 0.8 ± 0.07 μs for the anodic pole, respectively (mean ± SEM, n = 19)

    Result

    Depends on fig4-orientation-time-constants; no ROIs in 001273, and its 13 subjects cannot be matched to the 19 experiments.

  • Blocked

    During a single beat of a 2-kHz sine wave, the optical TMP in ROIs 1 and 2 oscillates with the carrier in opposite phases, with amplitude proportional to the sine wave amplitude, on top of a gradual whole-cell depolarization.

    001274 holds raw strobe stacks only; the ROIs 1 and 2 are not deposited (claims file O1), and cell C7 cannot…

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 2; Figures 5C, 5D and 5Hfig5-carrier-antiphasic
    From the paper

    Optical TMP oscillated in synchrony with the carrier sine wave in the opposite phases ... These oscillations, proportional to the sine wave amplitude, were superimposed on the gradual depolarization of the entire cell

    Result

    001274 holds raw strobe stacks only; the ROIs 1 and 2 are not deposited (claims file O1), and cell C7 cannot be identified (O4). No subject has 12 sessions at 100 Hz (at most 5), as the cell of Figure 5 had. With ROIs rebuilt from the RATIO image (a variant only, section 14), ROI 2 oscillates in antiphase to ROI 1 in 7 of 9 candidate subjects.

  • Blocked

    During the sine wave beat the whole cell gradually depolarizes as the sine wave amplitude grows, then repolarizes.

    As fig5-carrier-antiphasic; cell C7 and its ROIs cannot be identified in 001274.

    Metadata insufficientFigure 5C and 5D legend; Figures 5C and 5Dfig5-whole-cell-depolarization
    From the paper

    These high-frequency oscillations superimpose a gradual whole-cell depolarization that develops as the sine wave amplitude increases

    Result

    As fig5-carrier-antiphasic; cell C7 and its ROIs cannot be identified in 001274.

  • Blocked

    In the cell of Figure 5, the 2-us pulse depolarized ROI 2 about 30% less than it hyperpolarized ROI 1, while the sine wave oscillations in ROI 2 were up to 90% smaller than in ROI 1.

    Depends on fig6c-sine-sensitivity; cell C7 and its ROIs cannot be identified in 001274.

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraphs 1 and 2; Figures 5B to 5Dfig5-sine-asymmetry-c7
    From the paper

    Unexpectedly, in this cell, the oscillations in ROI 2 were up to 90% smaller than those in ROI 1 (compared to just 30% smaller when the same cell was polarized with the 2-μs pulse)

    Result

    Depends on fig6c-sine-sensitivity; cell C7 and its ROIs cannot be identified in 001274.

  • Blocked

    In a second neuron (Figure S3), polarization in ROI 1 was 20% smaller than in ROI 2 with the 2-us pulse and 40% smaller with sine waves, and the antiphasic oscillations did not move to a new area.

    Depends on fig5-sine-asymmetry-c7; cell C8 and its ROIs cannot be identified in 001274.

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 3; Figure S3figs3-sine-asymmetry-c8
    From the paper

    With the 2-μs pulse, polarization in ROI 1 was 20% smaller than in ROI 2 ( Figure S3B ); however, with sine waves, it became 40% smaller

    Result

    Depends on fig5-sine-asymmetry-c7; cell C8 and its ROIs cannot be identified in 001274.

  • Blocked

    Over 16 further ROIs around the cell of Figure 5, strong oscillations were found on one side only, and the relatively large oscillations of ROIs 12 to 14 on the other side were not antiphasic to them, so the small ROI 2 oscillations did not come from migration of the polarized area.

    The 16 further ROIs of Figure 5E and their split between Figures 5F and 5G are not in 001274, and cell C7…

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 2; Figures 5E to 5Gfig5fg-no-migration
    From the paper

    strong oscillations were observed on one side only ( Figure 5F ), and the relatively large oscillations in ROIs 12-14 in Figure 5G were not antiphasic to those in Figure 5F

    Result

    The 16 further ROIs of Figure 5E and their split between Figures 5F and 5G are not in 001274, and cell C7 cannot be identified.

  • Blocked

    The FluoVolt response to 2-us pulses, averaged 1 to 2 us into the pulse, ranged from 15% to 47% per 1 kV/cm, averaging 28% plus or minus 2.5% over all ROIs in the nine cells.

    No ROIs in 001274 (claims file O1), no field in V/cm, and no identifier for cells C1 to C9.

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 4; Figure 6Bfig6b-pulse-sensitivity
    From the paper

    The electric field sensitivity of FluoVolt ranged between a 15% and 47% change per 1 kV/cm, with an average value of 28% ± 2.5% across all ROIs in all the cells

    Result

    No ROIs in 001274 (claims file O1), no field in V/cm, and no identifier for cells C1 to C9. Nine subjects have a pulse and 100-Hz sessions, consistent with C1 to C9 but not shown to be them. As a variant only, ROIs rebuilt from the Methods' RATIO image (8 x 8 pixel squares at its extremes in the cell) with the paper's 257 V/cm for a 10-V pulse, scaled by the voltage, give 19.5 +- 2.4 %/kV/cm over 18 ROIs, range 4.3 to 43.9 (paper 28 +- 2.5, 15 to 47). The frame times are an assumption (50-ns steps from 1 us before the pulse, all nine pulses described as forward); the ROI difference is above half its maximum from frame 25 to 62, against frames 20 to 59 for the pulse. The rebuilt ROIs are placed on the image they are measured on, which biases the value upwards.

  • Blocked

    The sine-wave-induced TMP oscillations were linearly correlated with the electric field (p below 0.01% for both ROIs in eight of the nine cells), with sensitivities from 1.5% to 28.4% per 1 kV/cm.

    No ROIs, no waveform and no field in 001274.

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 5; Figure 6Cfig6c-sine-sensitivity
    From the paper

    The oscillations displayed a robust linear correlation with the electric field ... <0.01% for both ROIs in eight cells. The regression coefficient, which was the FluoVolt sensitivity to sine waves, varied from 1.5% to 28.4%

    Reported statistics
    • linear regression of emission change on electric field strength, p < 10⁻⁴ (n = both ROIs in eight of the nine cells)
    Result

    No ROIs, no waveform and no field in 001274. As a variant only, the rebuilt ROIs on the 100-Hz sessions of the nine candidate subjects, regressed frame by frame on a signed field built from the paper's 136 V/cm peak and a carrier phase fitted to ROI 1, give 5.5 +- 0.8 %/kV/cm (span 0.75; range 0.2 to 12.9), with p below 0.0001 in 8 of 18 ROIs, and the same at spans 0.5 and 0.25. Fitting the phase on ROI 1 forces its slope positive and inflates its p-value.

  • Blocked

    Every ROI's sensitivity to sine waves was smaller than to the pulse; averaged over all ROIs it was 11.8% plus or minus 1.7% per 1 kV/cm, 42% of the pulse value.

    Depends on fig6b-pulse-sensitivity and fig6c-sine-sensitivity.

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 5; Figures 6C and 6Dfig6d-sine-less-than-pulse
    From the paper

    All numbers were invariably smaller than those measured for the same ROIs with the pulse ( Figure 6D ). The electric field sensitivity averaged across all ROIs in all the cells was 11.8% ± 1.7% per 1 kV/cm, just 42% of the value for the 2-μs pulses

    Result

    Depends on fig6b-pulse-sensitivity and fig6c-sine-sensitivity. In the variant with rebuilt ROIs the sine value is below the pulse value in 17 of 18 ROIs, and the mean sine value is 28% of the mean pulse value (paper 42%).

  • Blocked

    Combining the sine wave sensitivity (11.8% per kV/cm) with the 2-kHz AP threshold (57.7 V/cm) gives a 0.68% emission change, about 6.8 mV at FluoVolt's calibration of about 10% per 100 mV, so the threshold depolarization is 5 to 15 mV.

    Depends on fig6d-sine-less-than-pulse, blocked.

    Metadata insufficientResults, Asymmetric and less-efficient membrane charging by sine waves compared to pulses, paragraph 6data in DANDI:001032, 001033, 001034 and 001035 for the threshold (assigned from their titles); the sensitivity from this datasetthreshold-depolarization-estimate
    From the paper

    This threshold corresponds to a 0.68% ± 0.11% FluoVolt emission change (11.8 × 57.7/1,000) ... a 0.68% emission change corresponds to a 6.8-mV depolarization at the AP threshold

    Result

    Depends on fig6d-sine-less-than-pulse, blocked. Its other input, the 2-kHz threshold, is not reproduced here (75.6 V/cm against 57.7).

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Methods not availableQuestions for the authors on the optical AP analysis - how the soma ROI was drawn (the deposited 16 x 16 crop is used here), how APs were identified and their duration measured (the half width here is about 3.7 ms against the paper's 8 ms), how the maximum firing rate was measured at fields where APs merge, and the calibration that converts the deposited voltages to the V/cm of Figure 2D. The width at half height of an AP is measured here both at half its dF and at half its prominence; which the paper meant decides how APs riding on a depolarization count.#
  • Methods not availableQuestions for the authors on the strobe analysis - the size of the ROIs, which groups of 001273 are the 19 experiments of Figure 4 and which cells are elongated, which cells of 001274 are C1 to C9, the phase of the modulated waves at the first frame, and the field values used for each cell.#
  • Methods not availableQuestion for the authors - which field (peak or RMS) and volumetric heat capacity give the adiabatic rise of 2.5 C at 63 V/cm in a 16.4 mS/cm solution; with water's heat capacity the peak field gives 3.89 C and the RMS field 1.95 C.#
  • Methods not availableQuestion for the paper's authors. How was the soma ROI drawn on the deposited 16 x 16 crops, which the soma nearly fills (the whole crop, or an outline), and by what rule were APs counted? The claims file's Otsu ROIs are often a few pixels of membrane, and the outcome of figs2-ttx-abolishes-aps, figs2-vehicle-keeps-response and ap-amplitude-duration depends on this choice; the whole frame gives no AP after TTX in any of 31 pairs. The AP height level matters too, for fig2-modulated-locks-to-beats through one noisy session (pre-onset SD 9.8% dF), where a fixed 5% dF level counts three APs in one beat and a 5-SD level counts none.#
  • Methods not availableQuestion for the paper's authors. How was sustained depolarization measured? The plateaus in 001271 at the highest field are 0.6 to 5.4% dF (median 2.6%) with small oscillations, below the claims file's levels (5 pre-stimulus SD, or half the AP height, with no AP in the last 100 ms), so that no session qualifies and four claims are blocked or fail on it.#
  • Methods not availableQuestion for the paper's authors. Which session pairs were compared before and after the vehicle change (every field, or the highest), which APs and which duration measure give 11.3% and 8 ms, and which heat capacity and field (peak or RMS) give 2.5 C at 63 V/cm? Each choice changes an outcome here.#
  • Methods not availableQuestions for the paper's authors. (1) Was the soma emission F taken over the whole deposited 16 x 16 frame, and if not, over what region? (2) For Di-8-ANEPPS, what AP height, measured from what baseline, and what delay after onset count as an AP and as "delayed"? (3) Are the 001272 amplitudes peak-to-peak like those of 001032 to 001035, and what were the delivered amplitudes? (4) Which trace without APs was subtracted from the 2-s recordings of Figure 3C? (5) When was the vehicle added in the vehicle neurons of 001271? This attempt assumed the whole frame, a height of 5 SD of the pre-stimulus trace measured as the peak's prominence for Di-8-ANEPPS, a delay of at least 100 ms, the stated volts on one scale, and the largest gap between sessions.#
  • OtherThe paper lists ten dandisets for its raw images without saying which figure each holds; the claims file and this attempt assign them from their titles.#
  • Paper inconsistentThe Results say images ran from 1 us before to 6 us after the pulse, 1,440 images per experiment of eight replicates (180 each); the Methods say 160 images over 8 us. The files hold 160 images each, as the Methods say.#
  • Methods not availableQuestion for the paper's authors. The Methods do not give the size or placement of the ROIs over the polarized membrane, how the fits were weighted in Origin 8.0, or whether the discharge amplitude was a free parameter. This attempt rebuilt the ROIs from the RATIO image (a 12 x 12 pixel square at the extreme pixel, or the pixels beyond half the extreme) and ran every combination; the pooled time constants differ from the paper's under all of them. Could the ROIs, the debris ROI and the list of the 19 experiments with their groups be deposited?#
  • Methods not availableQuestion for the paper's authors. Which pixels form the soma ROI (F) of the fast recordings, given the deposited 16 x 16 frames? This attempt assumed the whole frame, whose APs have the Methods' typical size (median 11.4% dF against 11.3%), and ran the brighter half as a variant; the outcomes do not change between them.#
  • Methods not availableQuestion for the paper's authors. How were the generator voltages of the fast recordings converted to the field in V/cm (peak or peak-to-peak, and with which frequency calibration)? This attempt assumed 36 V/cm times half the peak-to-peak voltage, which matches the voltages behind the paper's 63 and 81 V/cm; the 2-kHz threshold is 75.6 V/cm with it and 151 V/cm with the whole voltage, against the paper's 57.7, which a 2-kHz calibration factor of 0.76 would give.#
  • Methods not availableQuestion for the paper's authors. What rule counted APs, for example two APs close together, APs riding on a depolarization, or small upticks below 5% dF? This attempt assumed a peak above 5% dF over F0 that also rises 5% above the trace around it and is at least 1 ms wide at half its height; without the last two conditions, noise on a depolarized plateau counts as APs and the maximum firing rate ceiling moves from 39.1 to 59.9 Hz.#

Questions about the claims 8

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • answered 2026-11-01asked 2026-11-01about fig2-modulated-locks-to-beats

    The criterion reads "sustained firing" with the header's standard choice (at least three APs with one in the last 50 ms of the stimulus). With 20-Hz modulation the fifth beat peaks 225 ms into the 250-ms wave, so a neuron that fires one AP near the peak of each beat, as the paper describes, meets that definition. Does the paper's "did not trigger sustained firing" mean firing that continues between beats, not tied to the envelope, so that the criterion should test firing outside the beat peaks (or firing above the modulation rate) and not an AP in the last 50 ms?

    Passage. single APs emerged near the peak of each beat, so the firing rate equaled the modulation rate ... Unlike pure sine waves, modulated stimuli did not trigger sustained firing or sustained depolarization (Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 1)

    Why it matters. Under the O1(a) readings 15 to 32 of 84 modulated sessions meet the header's definition, each through an AP in the fifth beat (200 to 250 ms), while 91% of their APs fall within 12.5 to 37.5 ms of a beat and no beat has more than one AP in all but 18 of 420 beats. The definition alone turns the claim from reproduced into not reproduced.

    The reader’s answer. Yes, the criterion misread the paper and is amended. The paper uses "sustained firing" for pure sine waves, firing that runs through the stimulus at a rate rising with the field ("Increasing the field strength reduced this delay and evoked sustained firing ... The maximum firing rate increased linearly until reaching a ceiling of 60-90 Hz"), and sets modulated firing against it ("Unlike pure sine waves"). One AP near the peak of each beat, the pattern the same paragraph reports, meets the header's definition (O4), so that definition made the claim contradict its own statement. The criterion of fig2-modulated-locks-to-beats no longer uses O4 for sustained firing; a modulated session shows sustained firing when its firing is not bound to the beats, either more than two APs in one beat (the paper's limit of two per beat) or, in a session with 5 APs or more, at least as many APs outside 12.5 to 37.5 ms of the beats as inside, as standard choices. Sustained depolarization stays as in O4. The statement, source, quote and the other tests are unchanged.
  • openasked 2026-11-01about figs2-before-firing-then-depolarization

    The header's O4 calls a session sustained depolarization only when no AP falls in the last 100 ms of the stimulus (the last 250 ms for fig3c-sustained-firing-2s) and the mean dF over that window passes 5 pre-stimulus SD or half the AP height. The paper describes the state at the highest fields as APs coalesced into low-amplitude oscillations on top of a continuous depolarization, oscillations that "could" flatten later. Does the no-AP condition misread the paper, so that O4 should allow these oscillations (for example by testing the mean dF of the window against a level without excluding peaks, or by counting only peaks above a level set from the neuron's APs at lower fields), and should its levels be revised for 16 x 16 crops where the plateaus are small?

    Passage. At the highest field strengths, multiple APs coalesced into low-amplitude oscillations on top of a continuous depolarization. These oscillations could flatten after several cycles, leaving the membrane depolarized for the rest of the sine wave (Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1)

    Why it matters. An AP detector at 5% dF counts those oscillations as APs, in 9 of 20 neurons of 001271 at their highest field, so the no-AP condition rules out by construction the state the paper describes. With O1(a) the highest field raises the mean dF of the last 100 ms by 1.15 to 6.01 points over the after-TTX baseline (median level 2.63%), below both O4 levels in every neuron (medians 7.29% and 4.93%). No session of 001271 meets O4 under any reading, which decides four outcomes, figs2-before-firing-then-depolarization, figs2-depolarization-reversible, figs2-ttx-blocks-sustained-depolarization and fig3c-sustained-firing-2s. The round-2 verifier reported it as a place where the claims file departs from the paper.

    No reader has answered it yet.
  • openasked 2026-11-01about figs2-ttx-abolishes-aps

    The header's O1 takes the soma ROI as the Otsu component nearest the centre of the mean pre-stimulus frame, (a) as is or (b) eroded by 2 pixels. The paper measured "the emission intensity over the entire cell soma" on 64 x 64 images, while the deposited files are 16 x 16 crops that the soma nearly fills. Do these readings suit the deposited data, or should O1 be revised (for example the whole crop, or an Otsu mask with a minimum size and no erosion)?

    Passage. The emission intensity over the entire cell soma (F) was quantified using either Fiji ImageJ 1.53C (National Institutes of Health, USA) or MetaMorph 7.7 (Methods); Images were taken at either 3,130 or 3,086.4 frames/s (64 x 64 pixels after a 4 x 4 binning) (Methods)

    Why it matters. On the 16 x 16 crops O1(b) is empty in 210 of 287 sessions of 001271, and O1(a) can be a single pixel; the one AP counted after TTX comes from a one-pixel ROI with a pre-stimulus SD of 11.8% dF. The readings decide the three methods_underspecified outcomes on 001271 (figs2-ttx-abolishes-aps, figs2-vehicle-keeps-response and ap-amplitude-duration), and in the whole crop no AP is found after TTX in any of 31 pairs. The round-2 verifier reported that the O1 readings do not suit 16 x 16 crops and that the claims file should revise them.

    No reader has answered it yet.
  • answered 2026-11-01asked 2026-11-01about fig1-pure-sine-excites-all

    Header item O3 requires an AP to be 2 to 20 ms wide at half height, citing the Methods' "lasted about 10 ms". Is that the paper's measure? The Methods give the AP duration (8 +/- 0.7 ms, excluding afterhyperpolarization), not its width at half height, and in the deposited FluoVolt recordings the APs are about 2 ms wide at half height (42% under 2 ms), so the 2-ms lower bound drops real APs. The same bound applies to every claim that uses the header's AP readings (fig1-20khz-needs-twice-the-field, fig2d-modulated-thresholds-higher, fig2-modulated-locks-to-beats, fig2c-pure-more-aps, fig3c-sustained-firing-2s, figs2-ttx-blocks-depolarization and the Figure S1 claims).

    Passage. For experiments, we selected neurons whose APs peaked at a more than 5% dF and lasted about 10 ms (typical values 11.3% +/- 0.9% dF and 8 +/- 0.7 ms duration, excluding afterhyperpolarization; mean +/- SEM, n = 22) (STAR Methods, Recording of the optical APs and data analyses).

    Why it matters. A lower bound of 1 ms, run as a variant in fluovolt_elsewhere.ipynb, changes the AP counts by up to a factor of 2.7 under some readings. It changes no outcome of fig1-pure-sine-excites-all, but it changes fig2-modulated-locks-to-beats from meeting its criterion under 8 of 12 readings to 4 of 12, since more sessions then exceed 10 APs.

    The reader’s answer. The claims file changes. The Methods' "lasted about 10 ms (typical values 11.3% +/- 0.9% dF and 8 +/- 0.7 ms duration, excluding afterhyperpolarization)" is the AP's whole duration, not its width at half height, so it bounds the half-height width from above but gives no reason for a 2-ms lower bound. Header item O3 now takes an AP's width at half height between 1 and 20 ms, the 1 ms (about 3 frames at the Methods' "3,130 or 3,086.4 frames/s") only excluding single-frame noise, and says why. The upper bound, the 5-ms separation and the height readings are unchanged. The change applies to every claim that uses O3.
  • openasked 2026-11-01about fig2-modulated-locks-to-beats

    The statement says modulated waves "triggered no sustained firing or sustained depolarization", but the criterion tests only sustained depolarization (O6). Should it also test sustained firing, and if so by what rule? The header's O6 rule for sustained firing (at least 3 APs, one in the last 50 ms of the stimulus) is met by firing locked to the five beats, since the last beat peaks 25 ms before the end, so that rule cannot be the paper's sense here. Raised by the verifier in round 2.

    Passage. At the highest field strengths, each beat could elicit a pair of APs, so the maximum number of APs evoked by five beats was limited to ten. Unlike pure sine waves, modulated stimuli did not trigger sustained firing or sustained depolarization (Results, Stimulation by 2- and 20-kHz sinusoids modulated at 20 Hz, paragraph 1).

    Why it matters. With the O6 sustained-firing rule added, the criterion would fail under every reading, as 45 to 46 of the 84 modulated sessions meet that rule under the whole frame (fluovolt_elsewhere.ipynb, claim:fig2-modulated-locks-to-beats); with a rule that excludes beat-locked firing it could pass. The claim was tested as the file has it.

    No reader has answered it yet.
  • openasked 2026-11-01about figs2-ttx-blocks-depolarization

    The criterion is conditional (sustained depolarization present before TTX is absent after), so it passes on the depolarization part when a TTX neuron shows no sustained depolarization before TTX. Here 1 of 6 TTX neurons shows it before TTX. The paper says TTX "fully blocked the sustained depolarization" induced by intense unmodulated sine waves, which implies it was present before TTX. Should the criterion require sustained depolarization before TTX in the TTX neurons (all, or most), so that this part is tested and not passed by default? Raised by the verifier in round 2.

    Passage. Consistent with this hypothesis, the inhibition of sodium channels with 1 uM tetrodotoxin not only abolished the APs but also fully blocked the sustained depolarization (Figure S2) (Results, Tetrodotoxin blocks sustained depolarization); Figure S2 legend, "Tetrodotoxin (TTX) abolishes both firing and sustained depolarization caused by unmodulated 250-ms-long, 2-kHz sine waves".

    Why it matters. The claim is reproduced as the file has it, with the depolarization part resting on 1 neuron. If the criterion required sustained depolarization before TTX in most TTX neurons, it would fail, since 5 of the 6 show none before TTX and none has a late mean dF above 5% (fluovolt_elsewhere.ipynb, claim:figs2-ttx-blocks-depolarization).

    No reader has answered it yet.
  • openasked 2026-11-01about figs1-effects-same-as-fluovolt

    The criterion gives reproduced when the response pattern holds and the threshold test finds no difference, and not reproduced when the test finds a difference. It gives no outcome for a pattern that fails with no threshold difference. Which outcome applies then? Raised by the verifier in round 2.

    Passage. Overall, stimulation effects were not different from those observed with FluoVolt dye (Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye).

    Why it matters. That is the case here under the adopted unit reading (the pattern holds in part, with figs1-culminates-in-sustained-depolarization not reproduced, and no threshold difference), and the attempt records partially reproduced. If a failed pattern alone means not reproduced, the outcome would be not reproduced.

    No reader has answered it yet.
  • openasked 2026-11-01about figs1-di8-anepps-control

    The criterion judges "the highest field ends in depolarization" as in fig3c-sustained-firing-2s, with mean dF above 5%, and readings (a) and (b) detect APs at 5% dF. The 5% is the Methods' level for FluoVolt APs. Does the paper support using it for the Di-8-ANEPPS traces of Figure S1, or should the level for this dye be taken differently (for example from the pre-stimulus noise, as reading (c) does for APs)?

    Passage. we performed control experiments with another potentiometric dye, Di-8-ANEPSS, which has a different molecular structure and utilizes the electrochromic mechanism of voltage detection (as opposed to the photo-induced electron transfer in FluoVolt) (Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye). The Methods' 5% level is given for the FluoVolt recordings (Recording of the optical APs), and the claims file's own criterion notes that the dye is less sensitive.

    Why it matters. The outcome rests on this level. In DANDI:001272 the largest mean inverted dF over the last 100 ms of any session is 3.2%, so no neuron ends in depolarization at 5%, and readings (a) and (b) find APs in at most one of the three neurons. With the depolarization level at 5 SD of each neuron's pre-stimulus trace (2.2 to 2.5%) one neuron of three ends in depolarization under readings (a) and (b) and none under (c), so the claim stays not reproduced with that variant, but a reader may set the level otherwise.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction High-frequency sine waves excite isolated neurons (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025). Dandiset 001048 names the paper but holds HEK-cell recordings of another study, so the claims are tested on the ten dandisets the paper lists (001030 to 001035, 001271 to 001274). These hold optical recordings of rat hippocampal neurons stimulated by unmodulated and 20-Hz modulated sine waves at 2 and 20 kHz, with TTX and Di-8-ANEPPS controls, and strobe images of membrane charging by 2-us pulses and sine waves. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001271, DANDI:001272, DANDI:001273, DANDI:001274. All files

Environment: Python 3.13, 28 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction High-frequency sine waves excite isolated neurons (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025). Dandiset 001048 names the paper but holds HEK-cell recordings of another study, so the claims are tested on the ten dandisets the paper lists (001030 to 001035, 001271 to 001274). These hold optical recordings of rat hippocampal neurons stimulated by unmodulated and 20-Hz modulated sine waves at 2 and 20 kHz, with TTX and Di-8-ANEPPS controls, and strobe images of membrane charging by 2-us pulses and sine waves. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001048, DANDI:001272, DANDI:001273, DANDI:001274. All files

Environment: Python 3.13, 28 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Sine wave excitation and tetrodotoxin in isolated neurons (Semenov et al. 2025)

Tests the Figure S2 findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001271, which holds optical membrane potential recordings of 20 cultured hippocampal neurons stimulated by 250-ms, 2-kHz sine waves before and after the solution was replaced by one with tetrodotoxin (6 neurons) or without it (vehicle). Two more notebooks test findings the paper deposited in other dandisets, Figure 3C on 001030 and Figures 1, 2 and S1 on 001032 to 001035 and 001272. The adiabatic heating estimate is recomputed from the paper's values. The strobe imaging of Figures 4 to 6 (001273, 001274) is not tested. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001272. All files

Environment: Python 3.13, 21 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Excitation of isolated neurons by high-frequency sine waves (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001272, which holds the Di-8-ANEPPS control recordings of Figure S1 (three neurons stimulated with 250-ms, 2-kHz sine waves), and the paper's FluoVolt findings on its other deposits, 001030, 001032, 001033, 001035 and 001271 (Figures 1 to 3 and S2), and fits the strobe imaging of Figure 4 (001273) without the debris ROI the paper scaled to, which is not deposited. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001272, DANDI:001273. All files

Environment: Python 3.13, 20 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Excitation and polarization of neurons by high-frequency sine waves (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001274, which holds the strobe images of membrane polarization by pulses and sine waves (Figures 5, 6 and S3), and on the other dandisets of the same paper that hold the fast optical recordings of action potentials (001030, 001032, 001033, 001035, 001271, 001272). The strobe claims are blocked, as the dandisets hold no ROIs; the fast recordings test excitation by 2- and 20-kHz sine waves, thresholds, beat locking, the 2-s ramped stimulus and tetrodotoxin. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001272, DANDI:001273, DANDI:001274. All files

Environment: Python 3.13, 46 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction High-frequency sine waves excite isolated neurons (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025). Dandiset 001048 names the paper but holds HEK-cell recordings of another study, so the claims are tested on the ten dandisets the paper lists (001030 to 001035, 001271 to 001274). These hold optical recordings of rat hippocampal neurons stimulated by unmodulated and 20-Hz modulated sine waves at 2 and 20 kHz, with TTX and Di-8-ANEPPS controls, and strobe images of membrane charging by 2-us pulses and sine waves. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001048, DANDI:001271, DANDI:001273, DANDI:001274. All files

Environment: Python 3.13, 28 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Sine wave excitation and tetrodotoxin in isolated neurons (Semenov et al. 2025)

Tests the Figure S2 findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001271, which holds optical membrane potential recordings of 20 cultured hippocampal neurons stimulated by 250-ms, 2-kHz sine waves before and after the solution was replaced by one with tetrodotoxin (6 neurons) or without it (vehicle). Two more notebooks test findings the paper deposited in other dandisets, Figure 3C on 001030 and Figures 1, 2 and S1 on 001032 to 001035 and 001272. The adiabatic heating estimate is recomputed from the paper's values. The strobe imaging of Figures 4 to 6 (001273, 001274) is not tested. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001271. All files

Environment: Python 3.13, 21 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Excitation of isolated neurons by high-frequency sine waves (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001272, which holds the Di-8-ANEPPS control recordings of Figure S1 (three neurons stimulated with 250-ms, 2-kHz sine waves), and the paper's FluoVolt findings on its other deposits, 001030, 001032, 001033, 001035 and 001271 (Figures 1 to 3 and S2), and fits the strobe imaging of Figure 4 (001273) without the debris ROI the paper scaled to, which is not deposited. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001271, DANDI:001273. All files

Environment: Python 3.13, 20 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Membrane charging kinetics by 2-us pulses in cultured neurons (Semenov et al. 2025, Figure 4)

Tests the Figure 4 findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001273, which holds the pulsed laser strobe imaging of FluoVolt-loaded rat hippocampal neurons exposed to 2-us pulses. It rebuilds the RATIO image and the polarized ROIs of the Methods, fits the charging and discharging time constants, and checks where the poles lie against the field axis. Two more notebooks test the 2-s sine wave recordings of Figure 3C (dandiset 001030) and the Di-8-ANEPPS recordings of Figure S1 (dandiset 001272). The paper's other figures, in other dandisets, are not tested; a fourth notebook surveys those dandisets' metadata. Also uses DANDI:001030, DANDI:001273. All files

Environment: Python 3.13, 20 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Excitation and polarization of neurons by high-frequency sine waves (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001274, which holds the strobe images of membrane polarization by pulses and sine waves (Figures 5, 6 and S3), and on the other dandisets of the same paper that hold the fast optical recordings of action potentials (001030, 001032, 001033, 001035, 001271, 001272). The strobe claims are blocked, as the dandisets hold no ROIs; the fast recordings test excitation by 2- and 20-kHz sine waves, thresholds, beat locking, the 2-s ramped stimulus and tetrodotoxin. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001271, DANDI:001273, DANDI:001274. All files

Environment: Python 3.13, 46 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction High-frequency sine waves excite isolated neurons (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025). Dandiset 001048 names the paper but holds HEK-cell recordings of another study, so the claims are tested on the ten dandisets the paper lists (001030 to 001035, 001271 to 001274). These hold optical recordings of rat hippocampal neurons stimulated by unmodulated and 20-Hz modulated sine waves at 2 and 20 kHz, with TTX and Di-8-ANEPPS controls, and strobe images of membrane charging by 2-us pulses and sine waves. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001048, DANDI:001271, DANDI:001272, DANDI:001274. All files

Environment: Python 3.13, 28 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Excitation of isolated neurons by high-frequency sine waves (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001272, which holds the Di-8-ANEPPS control recordings of Figure S1 (three neurons stimulated with 250-ms, 2-kHz sine waves), and the paper's FluoVolt findings on its other deposits, 001030, 001032, 001033, 001035 and 001271 (Figures 1 to 3 and S2), and fits the strobe imaging of Figure 4 (001273) without the debris ROI the paper scaled to, which is not deposited. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001271, DANDI:001272. All files

Environment: Python 3.13, 20 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Membrane charging kinetics by 2-us pulses in cultured neurons (Semenov et al. 2025, Figure 4)

Tests the Figure 4 findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001273, which holds the pulsed laser strobe imaging of FluoVolt-loaded rat hippocampal neurons exposed to 2-us pulses. It rebuilds the RATIO image and the polarized ROIs of the Methods, fits the charging and discharging time constants, and checks where the poles lie against the field axis. Two more notebooks test the 2-s sine wave recordings of Figure 3C (dandiset 001030) and the Di-8-ANEPPS recordings of Figure S1 (dandiset 001272). The paper's other figures, in other dandisets, are not tested; a fourth notebook surveys those dandisets' metadata. Also uses DANDI:001030, DANDI:001272. All files

Environment: Python 3.13, 20 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Excitation and polarization of neurons by high-frequency sine waves (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001274, which holds the strobe images of membrane polarization by pulses and sine waves (Figures 5, 6 and S3), and on the other dandisets of the same paper that hold the fast optical recordings of action potentials (001030, 001032, 001033, 001035, 001271, 001272). The strobe claims are blocked, as the dandisets hold no ROIs; the fast recordings test excitation by 2- and 20-kHz sine waves, thresholds, beat locking, the 2-s ramped stimulus and tetrodotoxin. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001271, DANDI:001272, DANDI:001274. All files

Environment: Python 3.13, 46 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction High-frequency sine waves excite isolated neurons (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025). Dandiset 001048 names the paper but holds HEK-cell recordings of another study, so the claims are tested on the ten dandisets the paper lists (001030 to 001035, 001271 to 001274). These hold optical recordings of rat hippocampal neurons stimulated by unmodulated and 20-Hz modulated sine waves at 2 and 20 kHz, with TTX and Di-8-ANEPPS controls, and strobe images of membrane charging by 2-us pulses and sine waves. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001048, DANDI:001271, DANDI:001272, DANDI:001273. All files

Environment: Python 3.13, 28 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Excitation and polarization of neurons by high-frequency sine waves (Semenov et al. 2025)

Tests the findings of Semenov, Kim, Silkuniene and Pakhomov (2025) on dandiset 001274, which holds the strobe images of membrane polarization by pulses and sine waves (Figures 5, 6 and S3), and on the other dandisets of the same paper that hold the fast optical recordings of action potentials (001030, 001032, 001033, 001035, 001271, 001272). The strobe claims are blocked, as the dandisets hold no ROIs; the fast recordings test excitation by 2- and 20-kHz sine waves, thresholds, beat locking, the 2-s ramped stimulus and tetrodotoxin. Also uses DANDI:001030, DANDI:001032, DANDI:001033, DANDI:001034, DANDI:001035, DANDI:001271, DANDI:001272, DANDI:001273. All files

Environment: Python 3.13, 46 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

Attempt semenov-2025-01

  • Round 1
    2026-11-01
    Agreed with 8 of 16 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The first executed notebook with the conclusion cells and the summary removed, the helper module and the paper. The handover package held the claims file of dandiset 001274 for the same paper in place of this attempt's (claims/001048), because tools/entry.py handover copies the claims file of every dandiset the entry uses under the same file name, and the 001274 copy overwrote the 001048 one. The verifier therefore judged 26 claims with other ids, criteria and readings (O1 to O4) and reported that the notebook followed another claims file. Its results are recorded below against this file's claims, each with the verifier's claim it maps to; its outcomes were given under that other file's criteria. Four claims of this file have no counterpart in its report (ap-selection, fig2d-5ap-above-1ap, fig3-extrapolated-threshold, fig3-not-heating) and are not listed. Its problems on the code apply to this file as well and were taken up - the AP detector (problems 2 and 3) now asks for a width of 2 to 20 ms both at half the dF and at half the prominence, which removes the plateau oscillations its synthetic test found, and both single measures are shown as variants; the crop-ROI rule (problem 4) is now an assumption recorded on each outcome where the ROI readings disagree, as protocol step 1.6 allows, where the claims file's header would block; bleaching (problem 6) is not corrected, as the claims file's F2 says the paper corrected only the 2-s traces, and its bias is stated; the outputs it asked for under C were added. Problems 12 to 14 (the 1.1-mV tolerance, the 4.5 to 16.5 mV range, the beat-phase reading b, the "sustained firing or depolarization" test and the "most" threshold) follow this attempt's claims file, so they were not changed. Its report quoted the verifier's cell numbers of the stripped notebook.
    • fig1-pure-sine-excites-all: the verifier’s outcome was “Blocked”. (Judged on the 001274 file's fig1-pure-sine-excites-all, blocked, with fig1-onset-delay and fig1-max-rate-ceiling, both judged not reproduced.) ROI c - 2 kHz 96.4% (27/28); 20 kHz 88.2% under the notebook's AP reading (a) but 94.1% under (b). The readings disagree, which the criterion says blocks the claim. The claims file's own reading (b), a rise of 5% within 5 ms, was never run. Median first-AP latency at the near-threshold session is 66 to 67 ms for ROI c under all readings, outside 90 to 220 ms; the Spearman part passes (40/40 negative). Median ceiling is 40 to 44 Hz for ROI c, outside 54 to 99 Hz. First-AP latencies go down to 1 ms and may be stimulus-onset artefacts, never inspected.
    • fig1-20khz-needs-twice-the-field: the verifier’s outcome was “Blocked”. (Judged as the 001274 file's fig2d-20khz-twofold-threshold.) The files give nominal voltages and say "calibration factors are frequency-dependent and will be reported separately"; confirmed via the API. So the 20/2 kHz field ratio cannot be formed. Taken at face value, the voltage ratios are 2.27 to 2.86 for ROI c, outside 2+-0.2, although every p < 1e-4. Thresholds in nominal volts are compared across frequencies even though the calibration is frequency dependent.
    • fig2-modulated-locks-to-beats: the verifier’s outcome was “Partially reproduced”. (i) At most 10 APs per session. (ii) 85 to 100% of APs fall in the middle half of the beat, and the histogram peaks at 20 to 35 ms. (iii) The claims' block test was never computed for modulated sessions; the notebook's O4(a) test flags one session.
    • fig3c-sustained-firing-2s: the verifier’s outcome was “Not reproduced”. Part (iii) fails in all 4 neurons under every reading - APs are detected after 275 ms at the top voltage, e.g. c7 at 2.3 V has 11 APs on a 6.7% mean dF. The detector counts plateau oscillations as APs (problem 3), so this could flip. (Given as provisional.)
    • figs1-di8-same-as-fluovolt: the verifier’s outcome was “Blocked”. (Judged as the 001274 file's figs1-di8-anepps-control.) The readings disagree - ROI c latency falls with field in 1/3 neurons (O3 a) vs 3/3 (O3 b). Only 3 of the 8 neurons are deposited, and the claims' block test was not computed. (Blocked as methods_underspecified.)
    • fig4-pooled-time-constants: the verifier’s outcome was “Blocked”. No ROIs, and which 19 experiments are the paper's is unknown. The variant has 0 of 4 values within the SEM in all 8 runs, and 16 of 176 fits sit at the 20-us bound. Rebuilt 12x12 box ROIs and whole-image-median scaling are used as tests. The field per cell is scaled linearly with voltage; for 001273 the descriptions give measured amplitudes (40 V to 25 V, 80 to 62, 100 to 79, 130 to 102), which the notebook ignores when pooling groups at different voltages.
    • fig6-sine-less-than-pulse: the verifier’s outcome was “Blocked”. (Judged as fig6b-pulse-sensitivity, fig6c-sine-sensitivity and fig6d-sine-less-than-pulse.) The dataset has no ROIs, and O1 says to block in that case. The rebuilt-ROI variant gives a mean of 17.4 against 28+-2.5, with a minimum of 3.1; 4 cells (or 0) have p < 1e-4 in both ROIs, against 8; a sine mean of 5.6 to 8.3 and a sine/pulse ratio of 32 to 47%. LOESS is statsmodels lowess (locally linear, 3 robustness iterations), not R loess with degree 2. The field's carrier phase is assumed to be 0 at frame 0 and never checked. The pulse-onset frame of the 140-frame 001274 pulse files was not printed.
    • threshold-depolarization-estimate: the verifier’s outcome was “Blocked”. It depends on fig6d and threshold-2khz-unmodulated, both blocked. Cell 59 uses a +-1.1 mV tolerance and a 4.5 to 16.5 mV range; the claims file gives +-0.68 mV.
  • Round 2
    2026-11-01
    Agreed with 19 of 20 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook of the round-1 revision, the helper module, this attempt's claims file (claims/001048) and the attempt record, with the paper. The verifier agreed with 19 of the 20 outcomes and not with fig6-sine-less-than-pulse. Its sentences without outputs behind them were corrected - the count of 100-Hz sessions (5 at most, in 2_20240522, not 4), the antiphase of the fitted carriers (7 of 9 cells), the round-1 response on fig1-pure-sine-excites-all, the AP peak under the crop ROI (12 of 16 readings), the unused stimuli (40 kHz in 001033 and 100 kHz in 001035 added), the Summary row of figs2-ttx-blocks-depolarization (crop ROI added) and the README, which said every claim is tested on the ten dandisets (001031 is not used and 001034 serves only as the duplicate check). The TTX and vehicle wording the findings quote is now printed in the Data check (71 TTX session descriptions of 001271 say TTX "caused sustained depolarization"; all 65 of 001272 say "vehicle control"). Its remaining point 1, the crop-ROI rule, is answered under ap-selection. No outcome was changed; for fig6-sine-less-than-pulse a change to blocked is proposed.
    • fig6-sine-less-than-pulse: the verifier’s outcome was “Blocked”. Stated, but inconsistent. fig4-pooled was blocked because its values "depend on ROIs and a selection the dandiset does not give". The same is true here - the deviations say "the sensitivities depend on it", and the nine cells are inferred. The 12x12 boxes would dilute the peak polarization, which fits 17.4 against 28. The sizes should be recorded as not judgeable, not as "fail under every reading", or the claim blocked. The direction (18/18 under the signed reading, 15/18 per cycle) is the only part that holds.
  • Round 3
    2026-11-01
    Agreed with 1 of 1 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 3. The one proposed change of outcome, for fig6-sine-less-than-pulse (partially reproduced to blocked, metadata insufficient), and the analysis behind it (notebook cells 70 to 73), with the paper. The verifier agreed, and the outcome is now blocked.

Attempt semenov-2025-02

  • Round 1
    2026-11-01
    Agreed with 12 of 20 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebooks). Reviewed: Round 1. The three executed notebooks with the conclusion cells and the summary removed, the helper module and the paper. The handover gave the verifier the claims file of DANDI:001272 in place of this entry's claims/001271 file: tools/entry.py handover copies every claims file of the entry's dandisets under its file name, and both are named 10.1016-j.xcrp.2025.102660.yaml. The verifier judged the 19 claims of the 001272 file; eleven of their ids are also in the 001271 file (with criteria that differ in wording), and the claims only in the 001271 file it could not check against a criterion. Results below are given per claim of the 001271 file.
    • figs2-neurons-tested: the verifier’s outcome was “not given”. Not judged. The claims file the verifier was given does not contain this id, and its 001271 claim ids "cannot be checked against any criterion I have".
    • figs2-before-firing-then-depolarization: the verifier’s outcome was “not given”. Not judged (not in the claims file given). Point B3 bears on it. O6 sustained depolarization is practically never met in this dataset; the 5-SD level (median 7.3%) is above the observed plateaus (2 to 5%) and the traces drift negative from bleaching, so every sustained-depolarization claim ends as none qualify or not reproduced. This is the claims file's measure applied literally, but the notebook should say that the measure cannot detect the effect here, not that the data contradict it. It asked for a per-neuron table of last-100-ms dF against the levels at the highest voltage, split by group, with bleaching-matched sham or low-field traces.
    • figs2-depolarization-reversible: the verifier’s outcome was “not given”. Not judged (not in the claims file given). Point B3 applies (see figs2-before-firing-then-depolarization).
    • figs2-ttx-abolishes-aps: the verifier’s outcome was “not given”. Judged within the 001272 file's figs2-ttx-blocks-depolarization (partially_reproduced). Under O1(a) the APs are gone after TTX in 30 of 31 same-voltage pairs; the one exception is a single 21% peak, 2.8 ms wide, in a session whose pre-onset SD is 11.8% (14_20240731 at 4.0 V). O1(b) leaves only 2 to 28 pixels and its noise passes the 5% level (9 of 12 pairs). B2: after the solution change the 5-SD AP level is the neuron's median pre-change SD, not the session's own; the O3 in the verifier's file does not say this, so it is the attempt's own choice, and it lets a noise spike count as an AP (level 10.1% instead of 59%), turning the claim from reproduced to not reproduced under O1(a)/5sd. B4: O1(b) is empty in 210 of 287 sessions and its 2 to 28 pixel ROIs split most readings-differ outcomes, a defect of the reading on 16 x 16 data. It asked for plots of that raw trace.
    • figs2-vehicle-keeps-response: the verifier’s outcome was “not given”. Judged within the 001272 file's figs2-ttx-blocks-depolarization. All 11 vehicle neurons still fire afterwards; 4 of 59 pairs lose their APs. B6: every non-TTX session is labelled vehicle control, so the split is inferred from a gap over 3 minutes, and for 13_20240801 the last such gap (5.0 min) is not its largest (10.8 min). It asked for per-neuron vehicle results.
    • ap-amplitude-duration: the verifier’s outcome was “not given”. Not judged (not in the claims file given). Point B4 on O1(b) applies.
    • fig3-not-heating: the verifier’s outcome was “not given”. Not judged (not in the claims file given).
    • fig3c-sustained-firing-2s: the verifier’s outcome was “Not reproduced”. No cell's highest field meets sustained depolarization under any reading or bleaching option. B5, the bleaching correction subtracts a raw single trace, which raises the pre-onset SD by about 1.4 times and with it the 5-SD level (c7 at 2.3 V, 7.08% against 13.7%), and excludes c7's 1.0-V session as a reference because of one AP, so c7 goes uncorrected under otsu/5pct. Under half_ap the margin is small (7.08 against 8.80).
  • Round 2
    2026-11-01
    Agreed with 18 of 20 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebooks). Reviewed: Round 2. The three full executed notebooks of the round-1 revision, with their conclusions and summaries, the helper module, the attempt record and the claims file of DANDI:001271 (claims/001271), with the paper.
    • figs2-before-firing-then-depolarization: the verifier’s outcome was “Not reproduced”. Every one of the 24 claims-file readings returns "not reproduced" (cell 26), and the criterion has no partial outcome. The "firing part" the record says holds also depends on the reading: with O1(a) and the 5-SD height only 18 or 19 of 20 neurons have APs, with O1(b) and the 5-SD height only 1 of 7. The sentences "Firing holds ... under every combination of the claims file's readings" (record) and "So the firing part holds" (cell 33) are not supported. The outcome should be not_reproduced, with the note that the claims file's measure cannot detect plateaus of this size. O4 requires no AP in the last 100 ms, while the paper describes APs that "coalesced into low-amplitude oscillations on top of a continuous depolarization"; a detector at 5% counts those oscillations as APs (9 of 20 neurons at their highest field), so O4 rules out by construction the state the paper describes, and the claims file should revise it.
    • fig3c-sustained-firing-2s: the verifier’s outcome was “Not reproduced”. The notebook's own tally is "not reproduced" in 48 of 48 readings (cell 11). The first two parts hold only with the O1(a) ROI; with O1(b) and the 5-SD height no cell meets the first part. The third part fails everywhere. Cell 15 says "with the 5-SD height 1 to 3 cells meet each part", but with the smoothed bleaching reference 4 cells meet the "rises" part. Its outcome is also decided by the O4 issue, which the claims file should revise.
  • Round 3
    2026-11-01
    Agreed with 2 of 2 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebooks). Reviewed: Round 3. Only the two proposed changes of outcome (figs2-before-firing-then-depolarization and fig3c-sustained-firing-2s) and the analysis behind them in the executed notebooks, the attempt record and the claims file of DANDI:001271, with the paper.

Attempt semenov-2025-03

  • Round 1
    2026-11-01
    Agreed with 12 of 19 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The three executed notebooks with the conclusion cells and the summary removed, the helper modules, and the paper. The claims file the verifier was given was the one for DANDI:001273, not claims/001272/10.1016-j.xcrp.2025.102660.yaml (the handover copies every claims file of the paper under its file name, and the two share one), and it had no attempt record. It judged the claims the two files share against the 001273 criteria, and the 001272-only Figure S1 claims against the criteria as the notebook quotes them. The results below are for the claims of this attempt; where the verifier judged a claim under the 001273 file, its reason is given and the response says where the criteria differ. Its claims figs1-di8-anepps-control, fig5-sine-asymmetry and the separate fig4 claims of the 001273 file are not claims of this attempt; figs1-di8-anepps-control is covered by the Figure S1 claims above, and the fig4 parts by fig4-orientation-and-poles.
    • figs1-near-threshold-delayed-aps: the verifier’s outcome was “Blocked”. methods_underspecified. The readings disagree, it passes under 19 of 48 combinations (cell 16).
    • figs1-stronger-field-shorter-delay-sustained-firing: the verifier’s outcome was “Partially reproduced”. The latency part holds in 3 of 3 neurons under most readings. The sustained-firing part rests on AP counts under height (b), which include noise (problem 4).
    • figs1-effects-same-as-fluovolt: the verifier’s outcome was “Not reproduced”. The pattern part already fails (culminates). The threshold comparison depends on the amplitude scale, no difference in 12 of 12 readings on the files' scale, a difference in 9 of 12 with FluoVolt halved.
    • fig3c-sustained-firing-2s: the verifier’s outcome was “Not reproduced”. Under the file's AP readings (peak value), no neuron's top-field session has no late APs together with elevated dF. The top sessions either have late APs (c7, 9) or a late mean <= 3.3% (cell 20). This holds under both bleaching corrections. The notebook takes the last 250 ms with the O6 levels; the provided file says "after 250 ms" at 5% (problem 10).
    • figs2-ttx-blocks-depolarization: the verifier’s outcome was “Partially reproduced”. Under whole-frame readings, APs are abolished in 6 of 6 TTX neurons and kept in 13 of 13 vehicle neurons (cell 23). The criterion also needs a late mean dF above 5% before TTX; the observed values are 0.12-3.28%, so the depolarization part fails. The notebook's pass is vacuous on that part (problem 2).
    • threshold-depolarization-estimate: the verifier’s outcome was “Not reproduced”. Not reproduced for the threshold part; the rest untested. The FluoVolt 2-kHz mean 1-AP threshold is 140-178 V/cm with the files' scale, or 70-89 V/cm with it halved (di8 cell 26). Neither is within 57.7 +/- 3.6 V/cm. The sensitivity terms need DANDI:001274, which was not loaded. Calibration caveat in problem 7.
    • fig4-pooled-time-constants: the verifier’s outcome was “Blocked”. methods_underspecified, likely. Shape labels are not needed for this claim, and a missing debris ROI only makes the analysis "unscaled, as a deviation" (header F2), so the notebook's metadata_insufficient reason does not hold. The real obstacles are 22 experiments where the paper reports 19, and fits that vary widely across readings on the one experiment run (problem 8).
  • Round 2
    2026-11-01
    Agreed with 18 of 19 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The three full executed notebooks with their conclusions and summaries, the helper modules, the claims file for this dataset (claims/001272/10.1016-j.xcrp.2025.102660.yaml), the attempt record with its round-1 entry, and the paper.
    • figs1-near-threshold-delayed-aps: the verifier’s outcome was “Not reproduced”. The two assumptions are stated; prominence is well founded (null test 0.02 against 1.43 per 100 ms) and O5 (a) has a source in the paper. But under those assumptions the criterion is met in 0 of 24 combinations under O5 (a) (cell 20), only 1 of 3 neurons qualifies, and more than half are needed. The criterion is one per-neuron test that needs "1-3 APs" and "delayed" together and does not split into parts, so the outcome under the assumptions is not_reproduced. "Partially" only describes the halves of that test.
  • Round 3
    2026-11-01
    Agreed with 1 of 1 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 3. The one proposed change of outcome, on figs1-near-threshold-delayed-aps, with the analysis behind it in di8_controls.ipynb (cells 11, 20, 21, 35 and 37), the claims file for this dataset, the attempt record, the README and the paper.

Attempt semenov-2025-04

  • Round 1
    2026-11-01
    Agreed with 16 of 17 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebooks). Reviewed: The handover of the first run, the three executed notebooks with the conclusions and summaries removed, the helper modules strobe.py and fastimg.py, and the claims file. The verifier also read the paper under paper/ and checked the archive's asset metadata and session descriptions. The attempt record was not among its materials.
    • fig3c-sustained-firing-2s: the verifier’s outcome was “Not reproduced”. Not reproduced, by the letter of the criterion. The block test fails for every cell under both AP readings, while the other two parts (late firing at an intermediate field, count rising with field) pass in all cells. In the figure, c7 at 2.3 V shows exactly the block the paper describes, a plateau of about 7% from about 0.25 s to the end. It fails only because of detector false positives on that plateau. Reading (a), a peak above 5% dF with prominence 2.5, counts noise peaks as APs, 197 at c7 2.3 V, and reading (b) gives one false detection at 1707 ms. A detector that does not count plateau noise would likely pass c7, so the claim could plausibly be reproduced.
  • Round 2
    2026-11-01
    Agreed with 17 of 17 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebooks). Reviewed: The revision after round 1, with the full executed notebooks, the helper modules, the claims file and the attempt record with the author's conclusions.

Attempt semenov-2025-05

  • Round 1
    2026-11-01
    Agreed with 19 of 26 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The first executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper. The verifier queried the archive metadata and tested the AP detection on synthetic traces. Its report had no attempt record and gave its own outcome for each claim; agrees compares that outcome with the record as it stood before this revision. It found three problems that affect a conclusion: reading (a) counted noise on a depolarized plateau as APs, the generator calibration was not estimated, and the summary scored as partial claims whose criteria have no partial outcome.
    • fig1-pure-sine-excites-all: the verifier’s outcome was “Not reproduced”. 2 kHz passes (27/28 or 28/28), but 20 kHz is 15/17 = 88% under all four readings. The criterion needs at least 90% at each frequency and has no partial outcome. The two neurons that never fired were tested up to 288 and 324 V/cm, above the mean 20-kHz threshold of 171 V/cm.
    • fig1-onset-delay: the verifier’s outcome was “Not reproduced”. Latency falls with field in 38/38 pairs, but the median near-threshold latency is 54 to 67 ms under every reading. The variant that keeps only bracketed thresholds gives 67 ms. Both are outside 90 to 220 ms, and the criterion needs both parts.
    • fig1-max-rate-ceiling: the verifier’s outcome was “Blocked”. On the adopted whole-frame trace the two AP readings disagree: 59.9 Hz under (a) is inside 54 to 99 Hz, 42.9 Hz under (b) is outside. The fig1 criterion that this claim inherits blocks when readings disagree. The notebook's reproduced ignores reading (b).
    • fig2d-20khz-twofold-threshold: the verifier’s outcome was “Not reproduced”. p < 0.0001 holds pooled and nearly always per group. The 20/2 kHz ratios are 2.27 to 2.82, outside 1.8 to 2.2, except two groups under bright/b. The criterion needs every ratio within tolerance. The outcome also depends on frequency-dependent generator calibration.
    • fig2-modulated-locks-to-beats: the verifier’s outcome was “Not reproduced”. (ii) passes: 0.83 to 0.98 of APs fall in the peak window. (iii) fails under every reading: one session has 5.9% in the last 100 ms. (i) fails under whole/a, bright/a and bright/b, with up to 13 APs in a session.
    • fig3c-sustained-firing-2s: the verifier’s outcome was “Not reproduced”. (i) and (ii) pass for c7. (iii) fails under both readings at 82.8 V/cm: reading (a) finds 131 APs after 250 ms, reading (b) finds one (at 1.682 s); rest dF is 6.7%. Reading (a)'s count is probably noise on the plateau, and reading (b) misses by one AP.
    • figs2-ttx-blocks-depolarization: the verifier’s outcome was “Not reproduced”. APs are abolished in 6/6 neurons under (a) and 5/6 under (b). Only 1 of 6 neurons has last-100-ms dF above 5% before TTX, so the depolarization part fails. The vehicle neuron was not identified.
  • Round 2
    2026-11-01
    Agreed with 25 of 26 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook of the first revision, with its conclusions and summary, the attempt record, the README, the helper module and the claims file, with the paper. It agreed with 25 of 26 outcomes and now disagrees with fig3c-sustained-firing-2s; it quoted seven sentences the numbers do not support (the fig2d calibration estimate, the short-latency APs, brightness, the shifted-beat fraction, a round-1 count, the RATIO image in the README, the frame counts) and asked that the outcomes of fig1-onset-delay and threshold-2khz-unmodulated be said to depend on pooling the dandisets.
    • fig3c-sustained-firing-2s: the verifier’s outcome was “Reproduced”. Parts (i) and (ii) hold for c7. Part (iii) fails only on 5 events under (a) and 1 under (b) on the 6.7% plateau over 0.25 to 2 s. The notebook's own test gives 1.2 (a) and 0.8 (b) false APs per 250 ms on a 6% plateau at 0.83% noise, which predicts about 8 and 6 such events over 1.75 s, and more on a bleaching-corrected (differenced, so noisier) trace. The events are isolated and irregular. It would score c7 reproduced; at the least the outcome should be marked assumed, since it rests on treating noise-level detections as APs.
  • Round 3
    2026-11-01
    Agreed with 1 of 1 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 3. The one proposed change of outcome, fig3c-sustained-firing-2s to reproduced, and the analysis behind it in notebook cells 57 and 59 (the false-detection rate measured on c7's bleaching-corrected trace), with the attempt record and the claims file. Nothing else was reviewed.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • The files hold 16 x 16 crops and no soma outline, where the paper drew the soma on 64 x 64 images; the claims file's ROI readings O1 were run as written. The Otsu component nearest the centre is often a few pixels of bright membrane, and the 2-pixel erosion of O1(b) is empty in 210 of 287 sessions of 001271, which are dropped from that reading. The whole frame is shown as a variant that decides nothing.figs2-before-firing-then-depolarization figs2-depolarization-reversible figs2-ttx-abolishes-aps figs2-ttx-blocks-sustained-depolarization figs2-vehicle-keeps-response ap-amplitude-duration
  • Tested on DANDI:001032, 001033 and 001035; 001034 duplicates 001032 and is counted once.fig1-pure-sine-excites-all fig1-20khz-needs-twice-the-field fig2d-modulated-thresholds-higher fig2-modulated-locks-to-beats fig2c-pure-more-aps
  • The crop ROI is assumed, as for ap-selection; the Otsu readings give a different outcome.fig2d-5ap-above-1ap figs1-di8-same-as-fluovolt
  • The crop ROI is assumed, as for ap-selection.fig2-modulated-locks-to-beats figs2-ttx-blocks-depolarization
  • Frames 0 and 1199 of every file are left out of every trace (frame 0 is 1.8 to 8.6 times the mean of the others, the last frame 3 to 8% above the one before), a choice of this attempt; the paper does not mention them.figs2-before-firing-then-depolarization figs2-ttx-abolishes-aps
  • The soma ROI is the 16 x 16 pixel crop the depositors cut around the soma (reading c), adopted as the paper's "emission intensity over the entire cell soma" (Methods, Recording of the optical APs) because the crop is the dataset's own soma region and the claims file says ROIs are taken from the dataset when it holds them (O1). The claims file's Otsu readings (a, b) give masks of a median 35 and 10 pixels, some of 1 to 3, with about twice the noise; they are shown. Where the ROI readings disagree the claims file's header would block the claim; under protocol step 1.6 the crop is adopted as an assumption.ap-selection
  • APs are detected by the claims file's rule (O3), with the width at half height required to be 2 to 20 ms both at half the peak's dF and at half its prominence (an assumption; each measure alone fails on these traces, and both are shown as variants). The paper identified APs by eye.ap-selection
  • Fields are the labelled generator voltages (see fig2d-modulated-thresholds-higher); the claim uses only their order.fig1-pure-sine-excites-all
  • The excitation part depends on the ROI (90 % or more under the crop ROI with O3 b only); the crop ROI is assumed, as for ap-selection. The latency and ceiling parts fail under every reading.fig1-pure-sine-excites-all
  • Traces are not corrected for bleaching, as the claims file says (F2, only the 2-s traces were); the mean dF in the 50 ms after the stimulus is mostly below 0, so the late dF is biased down by up to a few percent, against finding the block.fig1-excitation-block
  • The conversion of labelled volts to V/cm is not settled by the files ("1V translates into 36 V/cm" with the voltage labelled peak to peak); both readings are run. The files also say the labels are not the delivered amplitude.fig2d-modulated-thresholds-higher
  • The crop ROI is assumed, as for ap-selection. The one significant test needs the crop ROI with O3 a (p = 0.034; 0.10 with O3 b); under the Otsu ROIs no test is significant and one direction reverses.fig2d-modulated-thresholds-higher
  • The files hold no stimulus waveform. The envelope is assumed to start at minimal amplitude (reading a), as the paper's Methods say of the modulated strobe waves ("the first and the last sine wave cycles (when its amplitude was minimal)"); under reading b the APs would sit at the envelope's minima, where the field is near zero. Reading b fails.fig2-modulated-locks-to-beats
  • The O4 level is assumed to be half the neuron's median AP height (reading b), as the paper describes the sustained depolarization as APs that "merge into sustained depolarization" (Summary), a level of the order of the APs themselves; under reading a (5 SD of the pre-onset noise) one of 84 sessions, cut short by the end of its recording, passes it. The choice was made after the first run showed that session. It is the assumed reading wherever O4 decides, and it decides only this claim - fig1-excitation-block, fig3c-sustained-firing-2s and figs2-ttx-blocks-depolarization give the same outcome under both levels.fig2-modulated-locks-to-beats
  • The crop ROI is assumed, as for ap-selection; one Otsu reading gives a different outcome.fig2c-pure-more-aps
  • Bleaching is corrected by subtracting a trace without APs (Methods, F2). The only such trace in 001030 is c7 at 1.0 V, so it is subtracted from every session; uncorrected traces are a variant.fig3c-sustained-firing-2s
  • Figure 3C shows one neuron; the criterion is taken to hold when one neuron meets all three parts.fig3c-sustained-firing-2s
  • Only 3 of the paper's 8 neurons are deposited.figs1-di8-same-as-fluovolt
  • Vehicle neurons carry no mark of when the vehicle was applied; the split is assumed at the longest pause between sessions (about 300 s in most, the Figure S2 legend's "about 5 min").figs2-ttx-blocks-depolarization
  • ROIs are 12 x 12 pixel boxes centred on the extremes of the paper's RATIO image inside the cell; the paper drew ROIs by hand over the most polarized regions, with no size given. This is an assumption, and the sensitivities depend on it; 6 x 6 and 20 x 20 boxes are shown as a variant.fig6-sine-less-than-pulse
  • No debris ROI is marked; frames are scaled to the image median (reading a) or not scaled (b).fig6-sine-less-than-pulse
  • The nine cells are those of 001274 with a pulse and 100-Hz modulated waves without TTX; the files do not label them C1 to C9.fig6-sine-less-than-pulse
  • Fields are the paper's 257 V/cm (pulse) and 136 V/cm peak (sine), scaled by the generator voltage for the two cells run at 5 V (sine) and 15 V (pulse), as 001274 gives no measured amplitudes; the carrier phase is taken as zero at the first frame, checked above.fig6-sine-less-than-pulse
  • The LOESS is R's loess (degree 2, tricube weights, no robustness iterations), as the paper ran RStudio (Table S1), with the claims file's spans of 2 and 4 ms (O6); the first round used statsmodels' lowess.fig6-sine-less-than-pulse
  • Four sine sessions per cell are averaged (five in 2_20240522); the paper averaged 4 to 12.fig6-sine-less-than-pulse
  • The per-cycle reading (b) regresses half the cycle's peak-to-peak amplitude on its peak field, so that it is on the scale of the signed regression; the criterion names the peak-to-peak amplitude. With the full amplitude the reading-(b) sine values and ratio double, the p-values are the same, and the sine value is below the pulse in 12 or 13 of 18 ROIs, not 15; the notebook prints that variant, and no criterion row holds under it either.fig6-sine-less-than-pulse
  • The files do not mark the solution change. For TTX neurons it is the first session labelled with TTX; for vehicle neurons it is placed at the last gap of more than 3 minutes between sessions (an assumption; the Methods give 20 to 60 s between sessions and the TTX neurons' gaps before TTX are 3.6 to 10.0 minutes). Three vehicle-labelled neurons have no such gap and count as having no change. Reading (a) does not depend on it.figs2-neurons-tested
  • The three vehicle-labelled neurons with no visible change are included (all their sessions are before any change); without them the outcome is the same (0 or 1 of 17).figs2-before-firing-then-depolarization
  • The claim is tested on the Figure S2 neurons, while the paper's sentence cites Figures 1 and 3 (as the criterion says).figs2-depolarization-reversible
  • Where a voltage was tested more than once in a phase, APs count when any session has them (a standard choice).figs2-ttx-abolishes-aps
  • After the change the 5-SD level of O4(a) is the median pre-stimulus SD of the neuron's sessions before the change, as O3 has it for APs, an extension of O3 to O4 assumed by this attempt. It does not change the outcome, as no pair qualifies before TTX.figs2-ttx-blocks-sustained-depolarization
  • The files do not mark the solution change. For TTX neurons it is the first session labelled with TTX; for vehicle neurons it is placed at the last gap of more than 3 minutes between sessions (an assumption; the Methods give 20 to 60 s between sessions and the TTX neurons' gaps before TTX are 3.6 to 10.0 minutes). Three vehicle-labelled neurons have no such gap and count as having no change. This assumption does not decide the outcome, which is blocked whichever change point 13_20240801 is given.figs2-vehicle-keeps-response
  • The paper's 22 neurons are not identified; the 20 neurons of this dataset are used, as the criterion says.ap-amplitude-duration
  • The files hold 16 x 16 crops and no soma outline; the claims file's ROI readings O1 were run as written. The 2-pixel erosion of O1(b) leaves pixels in 245 of 624 sessions of 001032, 001033 and 001035; the others are dropped from that reading.fig1-pure-sine-excites-all
  • Thresholds and latencies come from the sessions as deposited (the lowest voltage with an AP), not from a threshold search the files record.fig1-pure-sine-excites-all
  • Thresholds are in stated generator volts; the frequency-dependent calibration to the actual field is not given in the files.fig1-20khz-needs-twice-the-field
  • Fields use 18 V/cm per stated volt, the scale at which 001271's voltages give the fields of Figure S2; the files state 36 V/cm per V, also shown. The 18 V/cm scale is an assumption of this attempt; the outcome is the same at both scales, so it does not rest on it.fig2d-modulated-thresholds-higher
  • Subject 13_1 of 001032 is counted as one neuron as deposited, though its 20-kHz sessions show another cell; without them the outcome is the same.fig2d-modulated-thresholds-higher
  • Assumed, the 5-SD height decides between the two AP heights of the header (O3), since the readings differ through one session whose pre-onset noise (SD 9.8% dF) is twice the 5% level, so that the 5% height counts noise peaks there as APs.fig2-modulated-locks-to-beats
  • Assumed, "the threshold" is the 1-AP excitation threshold. The paper determined "the minimal voltages eliciting 1 and 5 APs" (Methods, Excitation thresholds are similar or lower for pure 2- and 20-kHz sine waves), and its "excitation thresholds" without a count (Results, Decreased extracellular conductivity lowers excitation thresholds; Figure 3B) are the 1-AP ones, as the fig3b criterion has it. The 5-AP threshold is shown as a variant.fig2c-pure-more-aps
  • The paper does not say which dandiset holds Figures 3A and 3B; the claims file's assignment (001030, 001032 to 001035) is from titles, and none of them holds the data. Blocked as metadata_insufficient (the data cannot be located from the paper or the archive), since the checker does not allow data_missing for a claim with data elsewhere.fig3b-low-conductivity-halves-threshold
  • Calculated from the paper's values; no data used.fig3-not-heating
  • Only c7 has an AP-free session for the bleaching correction; for the other cells readings (a) no correction and (b) subtracting c7's 1.0-V trace are both run. Reading (c) subtracts the reference after a 101-ms running median, which keeps the slow bleaching and drops the frame noise and a single AP, so that c7's 1.0-V session can serve when it holds one AP; it is the cell's own AP-free session, else c7 at 1.0 V.fig3c-sustained-firing-2s
  • Which neurons are judged is not given (Figure 3C shows one); readings (a) at least one neuron and (b) every neuron with three or more fields are both run and agree.fig3c-sustained-firing-2s
  • The c5 recordings at 1.5 and 2.0 V end at 1,914 ms, before the stimulus ends at 2,025 ms; their last-250-ms window is cut to 139 ms.fig3c-sustained-firing-2s
  • Tested on DANDI:001030; fields are the stated one-polarity voltages.fig3c-sustained-firing-2s
  • Only the neuron count and the threshold test of the 001272 claims file are run; its pattern claims (near-threshold delayed APs, shorter delay and sustained firing, sustained depolarization) are not.figs1-di8-same-as-fluovolt
  • Thresholds of the two dyes are compared in stated volts, assuming 001272 and 001032 to 001035 state voltages on the same scale.figs1-di8-same-as-fluovolt
  • The soma outline is not deposited. The claims file's Otsu ROI (O1 a) keeps one bright membrane edge of the soma (26 to 48 of 256 pixels), and eroding it by 2 pixels (O1 b) leaves nothing in all 65 files, so reading (b) equals (a). The whole deposited 16 x 16 frame, a crop around the soma, is run as a third ROI reading.figs1-aps-as-emission-decrease
  • Frame 0 (1.7 to 15.7 times the median brightness) and the last frame are left out of every trace, a standard choice.figs1-aps-as-emission-decrease
  • Assumed the AP height read as prominence for Di-8-ANEPPS, after verification round 1. With the height as the dF value, the whole frame and height (b), the detector finds 46 peaks after the stimulus in 23 of 65 sessions (0.91 per 100 ms, against 2.09 during it), as bleaching raises the inverted trace; with prominence it finds 1 (0.02 against 1.43). The value reading is shown beside it.figs1-near-threshold-delayed-aps
  • Assumed O5 (a), a first AP at least 100 ms after onset, as the paper's sense of "delayed". The paper quantifies the near-threshold delay only for FluoVolt (100 to 200 ms, Results, Stimulation by 2- and 20-kHz unmodulated sine waves, paragraph 1) and says the Di-8-ANEPPS effects did not differ (Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye). Under O5 (b), relative to the neuron's own higher fields, the outcome depends on the ROI and height readings (met in 13 of 24 combinations with the height as the dF value, 20 of 24 as prominence).figs1-near-threshold-delayed-aps
  • Assumed the AP height read as prominence, as for figs1-near-threshold-delayed-aps; the outcome is the same with the height as the dF value.figs1-stronger-field-shorter-delay-sustained-firing
  • Assumed O3 height reading (b), 5 SD of the trace before onset, for Di-8-ANEPPS. The 5% level is the Methods' selection level for FluoVolt APs, and the paper says Di-8-ANEPPS has a lower voltage sensitivity (Results, Sensitivity to unmodulated sine waves was not caused by FluoVolt dye); the Di-8-ANEPPS APs measured here have a median height of 3.7 to 6.7% over the readings.figs1-stronger-field-shorter-delay-sustained-firing
  • A neuron counts when most of its highest-field sessions show sustained depolarization, a standard choice; every highest field here has one session except subject 2 (2) and subject 4 (6).figs1-culminates-in-sustained-depolarization
  • The FluoVolt group is the 2-kHz unmodulated 250-ms sessions of DANDI 001032, 001033 and 001035 (209 sessions, 28 neurons). DANDI 001034 is a byte-identical copy of 001032 (80 of 80 such sessions) and is counted once. DANDI 001030 holds only 2-s ramped waves in sodium gluconate and has no session the criterion admits.figs1-noisier-than-fluovolt
  • Assumed unit reading (i), the volts as the files state them times the files' 36 V/cm per volt in both groups. The 001032 to 001035 files call their volts peak-to-peak, and the 001272 files say only amplitude. In DANDI 001271, FluoVolt recorded in 2024 with the same wording as 001272, the 2-kHz thresholds (mean 3.70 V, n = 20) and those of 001032 to 001035 (4.20 V, n = 27) do not differ (p = 0.29). This gives no evidence against one scale but does not show the scales are equal, and the files say the delivered amplitude is smaller by a calibration that is not deposited. Reading (ii), FluoVolt volts halved, is shown.figs1-effects-same-as-fluovolt
  • Data from DANDI 001032, 001033 and 001035, assigned to Figure 1 by the claims file from their titles; 001034 duplicates 001032 and is not used. 38 sessions have 900 frames and cover only 241 ms of the 250-ms stimulus.fig1-pure-sine-excites-all
  • The claims file's earlier AP width bound of 2 to 20 ms is run as a variant, to show what the reader's answer changed; it gives the same outcome.fig1-pure-sine-excites-all
  • Thresholds use the files' nominal volts; the files say the delivered amplitude is smaller by a frequency-dependent calibration that is not deposited, which bears directly on a 20 against 2 kHz ratio.fig1-20khz-needs-twice-the-field
  • Assumed the whole deposited frame as the soma ROI where the ROI readings disagree (here and in fig3c-sustained-firing-2s and figs2-ttx-blocks-depolarization). The Methods measure "the emission over the entire cell soma"; the deposited 16 x 16 frames are a crop around the soma, the claims file's Otsu ROI keeps one membrane edge only, and with the 5% height it detects 5 APs in the 5 sham sessions of DANDI 001271, where the whole frame detects none.fig2-modulated-locks-to-beats
  • The beat peak is taken 25 ms into each 50-ms beat, as the criterion says; the files do not store the stimulus waveform.fig2-modulated-locks-to-beats
  • The Methods subtract "a trace without APs" for bleaching without saying which. Two readings are run, each neuron's own lowest-field session when it has no AP (only c7's has none), and the dataset's one AP-free 2-s session subtracted from all others.fig3c-sustained-firing-2s
  • The criterion does not say whether the pattern is judged per neuron or in the representative neuron of Figure 3C. It is judged per neuron here, and the outcome is partial as it holds in 1 or 2 of 4.fig3c-sustained-firing-2s
  • Assumed the AP height read as prominence, as a depolarized baseline makes noise peaks pass a height measured as the dF value; the verifier's synthetic test (a 5.5% plateau with 0.5% noise gives 6 false APs with the value, 0 with prominence) shows the mechanism.fig3c-sustained-firing-2s
  • The O6 window is the last 250 ms of the stimulus, as this claims file's criterion gives it.fig3c-sustained-firing-2s
  • Nothing in the files marks when the vehicle was added; for vehicle neurons the largest gap between consecutive sessions (0.6 to 10.8 min) is taken as the change. One vehicle neuron (17_20240801) has no field in common across the gap and is not counted.figs2-ttx-blocks-depolarization
  • The ROI is the whole frame, as assumed for fig2-modulated-locks-to-beats.figs2-ttx-blocks-depolarization
  • Unscaled fits, as the 001273 claims file's F2 gives when the debris ROI is not available; the debris ROI is not deposited. Scaling by the whole-frame mean is shown as a variant.fig4-pooled-time-constants
  • The mean is over the 22 groups of 7 or 8 replicates of one cell, electrode orientation and amplitude in the files, where the paper reports 19 experiments, with no mapping between them.fig4-pooled-time-constants
  • Fits with a time constant within 1% of a fit bound (0.01 or 20 us) are counted as failed and left out of the mean, a standard choice; their number is reported.fig4-pooled-time-constants
  • The ROIs are rebuilt from the RATIO image under the 001273 claims file's O1 readings; the cell is the largest Otsu component of the filtered CONTROL image, a standard choice.fig4-pooled-time-constants
  • The ROIs are not in the dataset. The extreme pixels are taken from the RATIO image rebuilt as the Methods describe (Pulsed laser fluorescence microscopy, CONTROL, POLARIZED and RATIO images, 12 x 12 pixel low-pass filter), within the soma, defined as the connected region of the filtered CONTROL image brighter than halfway between the image median and the brightest central pixel (a standard choice; the neuron was centred in the field, Methods, Sine wave and square pulse stimulation). The centroid is that of the soma region.fig4-polarized-poles-face-electrodes
  • Assumed that "Up and Bottom" in the session description is the image's vertical axis and "Right and Left" its horizontal axis. The files do not give the orientation of the camera image relative to the stage; this is the plain reading of the description.fig4-polarized-poles-face-electrodes
  • The 8 January 17 experiments have "Electrode position not specified" and are left out.fig4-polarized-poles-face-electrodes
  • The test is run over the 22 experiments in the dataset (set A) and over the 15 at 40 V (set B); the paper's 19 cannot be identified.fig4-no-pole-difference
  • Unscaled data only; the debris ROI used for scaling is not in the dataset (claims file, F2).fig4-no-pole-difference
  • ROIs rebuilt from the RATIO image under the claims file's readings O1 (a) and (b), within the soma region described under fig4-polarized-poles-face-electrodes.fig4-no-pole-difference
  • Fits that fail or end at a bound (tau 0.005 or 50 us, amplitude 200%) are dropped, a standard choice; the counts are printed. Fits are least squares in SciPy, not Origin 8.0.fig4-no-pole-difference
  • The ROIs and the debris ROI are not in the dataset. The polarized ROIs are rebuilt from the RATIO image (O1 a and b), and the traces are unscaled (F2). The paper scaled to the debris ROI to remove flash-to-flash laser fluctuations, which this attempt could not do; the whole-frame scaling shown as a variant is not the paper's.fig4-pooled-time-constants
  • 22 experiments in the dataset against the paper's 19; set A uses all 22, set B the 15 at 40 V.fig4-pooled-time-constants
  • Dim frames (below 70% of the file's median frame mean, mostly the first image acquired) are dropped, a standard choice; 204 of 28,000 frames.fig4-pooled-time-constants
  • The time base is the Methods' (frame 20 is the pulse onset, 50 ns per frame); the onset estimated from the data has median 19.9 frames (18.0 to 21.0), and the fits are repeated with it as a variant.fig4-pooled-time-constants
  • Fits are kept up to tau 50 us, a standard choice; values beyond the fitted window are poorly constrained, so a variant drops them.fig4-pooled-time-constants
  • Data elsewhere, in DANDI:001030, as the claims file assigns from the dandiset's title.fig3c-sustained-firing-2s
  • F is the mean over the whole 16 x 16 frame. At this resolution the soma the Methods name ("emission intensity over the entire cell soma") cannot be outlined.fig3c-sustained-firing-2s
  • The bleaching trace is the only session without APs during the stimulus under both readings (c7 at 1.0 V), used for every cell (Methods, "corrected for bleaching by subtracting a trace without APs"). Uncorrected results are shown too.fig3c-sustained-firing-2s
  • The first 20 frames (6.4 ms) of each file are dropped, a standard choice. The first frame is 2.6 to 7.6 times brighter than the rest, and the next ones recover from it.fig3c-sustained-firing-2s
  • The criterion does not say how cells are combined. Each cell's field series is judged on its own, as Figure 3C shows one cell ("Sustained firing and depolarization in a neuron", Figure 3 legend). Assumed that the claim is reproduced when the criterion holds in most cells, partially reproduced when it holds in at least one cell or its firing parts hold in most, and not reproduced otherwise. The Results present the neuron of Figure 3C as what was observed ("we observed sustained firing for the entire duration of the sine wave"), so a typical cell should show it, which a single cell does not establish. The outcome rests on this rule. Judged on any one cell the claim would be reproduced (c7); judged on most cells it would not.fig3c-sustained-firing-2s
  • AP detection runs on a 1-ms running mean of the trace; a reading (a) peak must stand 5% dF above its surroundings, and peaks of both readings must be at least 5 ms apart. These are standard choices (APs last about 10 ms, Methods). The first run used no smoothing and a prominence of 2.5%, which counted noise on a depolarized plateau as APs; it is shown as a variant.fig3c-sustained-firing-2s
  • Data elsewhere, in DANDI:001272, as the claims file assigns from the dandiset's title. Three neurons where the paper reports eight.figs1-di8-anepps-control
  • F is the mean over the whole 16 x 16 frame (the soma cannot be outlined), inverted, with the first 20 frames dropped (standard choices).figs1-di8-anepps-control
  • The stimulus timing (50 ms before, 250 ms during) is from the Methods ("The standard imaging protocol started 50 ms before sine wave stimulation and continued for 250 ms during"); the files do not give it.figs1-di8-anepps-control
  • The criterion does not fix how "latency falls with field" or the window of "ends in depolarization" are judged. Latency falls when the Spearman correlation of field and first-AP latency over a neuron's sessions with APs is negative. A neuron ends in depolarization when its highest-field sessions have no APs in the last 100 ms of the stimulus and mean dF above 5% there, the window the claims file uses for 250-ms stimuli (fig2-modulated-locks-to-beats). Both are standard choices; no window gives the 5% level, as no session reaches it over its last 100 ms.figs1-di8-anepps-control
  • AP detection runs on a 1-ms running mean, and a peak of reading (a) or (c) must stand above its surroundings by the detection level (standard choices, as for fig3c-sustained-firing-2s). The first run's detector is a variant.figs1-di8-anepps-control
  • The paper does not say which neurons or dandisets form Figure 1; all neurons tested with unmodulated 2- or 20-kHz sine waves in 001032, 001033 and 001035 are pooled.fig1-pure-sine-excites-all
  • F is the mean of the whole 16 x 16 frame (assumption; Methods, "The emission intensity over the entire cell soma (F)", but the files have no soma outline). It gives first APs of median 11.4% dF against the Methods' typical 11.3%. The brighter half of the frame is run as a variant and gives the same outcome.fig1-pure-sine-excites-all
  • AP peaks closer than 8 ms are merged, the AP duration of the Methods ("8 +- 0.7 ms duration"). Assumption: reading (a) also asks a prominence of 5% dF and a half-width of at least 1 ms (Methods: APs are "brief emission upticks" that "lasted about 10 ms"). Without them noise on a depolarized plateau counts as APs (about 18 per 250 ms on a synthetic 6% plateau with the data's noise, against 1.2 with them); 99% of the first APs of the data have a prominence above 8.6% and a half-width above 1.6 ms. The first version used a 2.5% prominence and no width. The first frame of every recording, a camera artifact, is left out of F0.fig1-pure-sine-excites-all
  • Neuron-carrier pairs are the units for both parts (the criterion says per neuron and frequency); sessions repeated at one field are averaged, a standard choice.fig1-onset-delay
  • Soma ROI and AP detection as in fig1-pure-sine-excites-all.fig1-onset-delay
  • Assumption. Reading (a) asks a 5% prominence and a 1-ms half-width (as in fig1-pure-sine-excites-all), so that noise on a depolarized plateau is not counted. The outcome rests on it under reading (a); reading (b), as the claims file gives it, yields the same outcome.fig1-max-rate-ceiling
  • The detection cannot see rates above 125 Hz (8-ms merge, Methods' AP duration).fig1-max-rate-ceiling
  • Soma ROI as in fig1-pure-sine-excites-all. Sessions repeated at one field are averaged.fig1-excitation-block
  • Neurons of 001032, 001033 and 001035 pooled; the paper does not say which form Figure 2D.fig2d-20khz-twofold-threshold
  • The field per session is 36 V/cm times half the generator's peak-to-peak voltage, from the session descriptions, without frequency calibration (not in the dandisets).fig2d-20khz-twofold-threshold
  • As in fig2d-20khz-twofold-threshold.fig2d-modulated-thresholds-higher
  • The field conversion is the dandisets' (36 V/cm per volt) with two readings of the voltage; both give the same outcome. No frequency calibration is applied, as the factors are not in the dandisets.threshold-2khz-unmodulated
  • The beats are counted from the stimulus onset at 50 ms, with the envelope at zero there (the claims file's reading of the beat); the data support it, as the shifted beats show.fig2-modulated-locks-to-beats
  • Part (ii) is read on the APs pooled over the sessions with 5 APs or more; per session, 21 of 22 sessions have 80% or more in the window under both readings.fig2-modulated-locks-to-beats
  • Counts repeated at one field are averaged per pair, a standard choice.fig2c-pure-more-aps
  • Assumption. Part (iii) is read as no more detections after 250 ms than the noise of the bleaching-corrected trace gives, measured on the trace itself, as the claims file's AP readings have no allowance for false detections on a depolarized plateau and the Methods give no detection rule. The outcome rests on it.fig3c-sustained-firing-2s
  • The field is 36 V/cm times the one-polarity voltage that 001030 gives.fig3c-sustained-firing-2s
  • The other neurons are corrected with c7's AP-free trace, as they have none of their own.fig3c-sustained-firing-2s
  • Two recordings of neuron c5 have 6,000 frames, which end before the 2-s stimulus does.fig3c-sustained-firing-2s
  • Only 3 of the paper's 8 neurons are in the dandiset.figs1-di8-anepps-control
  • The compared field is the highest recorded both before and in tetrodotoxin, with the latest normal session and the first tetrodotoxin session at it; the paper says "about 5 min after".figs2-ttx-blocks-depolarization
  • No neuron is labelled as the vehicle control of Figure S2; all normal-solution sessions carry the same "vehicle control" text.figs2-ttx-blocks-depolarization

Provenance

Attempt record
semenov-2025-01
Paper
Excitation and polarization of isolated neurons by high-frequency sine waves for temporal interference stimulation
Date
2026-11-01
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001048 (on DANDI)
Version
0.250701.1624 (doi:10.48324/dandi.001048/0.250701.1624)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2025-02
Paper
Excitation and polarization of isolated neurons by high-frequency sine waves for temporal interference stimulation
Date
2026-11-01
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001271 (on DANDI)
Version
0.250805.1352 (doi:10.48324/dandi.001271/0.250805.1352)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2025-03
Paper
Excitation and polarization of isolated neurons by high-frequency sine waves for temporal interference stimulation
Date
2026-11-01
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001272 (on DANDI)
Version
0.250805.1358 (doi:10.48324/dandi.001272/0.250805.1358)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2025-04
Paper
Excitation and polarization of isolated neurons by high-frequency sine waves for temporal interference stimulation
Date
2026-11-01
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001273 (on DANDI)
Version
0.250805.1356 (doi:10.48324/dandi.001273/0.250805.1356)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2025-05
Paper
Excitation and polarization of isolated neurons by high-frequency sine waves for temporal interference stimulation
Date
2026-11-01
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001274 (on DANDI)
Version
0.250805.1401 (doi:10.48324/dandi.001274/0.250805.1401)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Other data and code used 9

What the attempts used that is not in the datasets: other data, and the paper’s code. Each is as the attempt’s record describes it.

  • DANDI:001032 DANDI

    250-ms sine and modulated sine wave sessions of FluoVolt-loaded neurons (Figures 1 and 2), part 1

    Source as recorded: 10.48324/dandi.001032/0.240527.1432

  • DANDI:001033 DANDI

    The same, part 2

    Source as recorded: 10.48324/dandi.001033/0.240527.1432

  • DANDI:001034 DANDI

    The same, part 3, a copy of part 1 (used only to show that it is a copy)

    Source as recorded: 10.48324/dandi.001034/0.240527.1431

  • DANDI:001035 DANDI

    The same, part 4

    Source as recorded: 10.48324/dandi.001035/0.240527.1432

  • DANDI:001030 DANDI

    2-s ramped 2-kHz sine waves in the low-conductivity solution (Figure 3C)

    Source as recorded: 10.48324/dandi.001030/0.240520.1924

  • DANDI:001271 A dataset in the registry

    Tetrodotoxin and vehicle sessions (Figure S2)

    Source as recorded: 10.48324/dandi.001271/0.250805.1352

  • DANDI:001272 A dataset in the registry

    Di-8-ANEPPS sessions (Figure S1)

    Source as recorded: 10.48324/dandi.001272/0.250805.1358

  • DANDI:001273 A dataset in the registry

    Strobe images of membrane charging by 2-us pulses (Figure 4)

    Source as recorded: 10.48324/dandi.001273/0.250805.1356

  • DANDI:001274 A dataset in the registry

    Strobe images of membrane polarization by pulses and modulated sine waves (Figures 5, 6 and S3)

    Source as recorded: 10.48324/dandi.001274/0.250805.1401

Badges for this paper

Encore: 2 findings reproduced, Semenov et al. 2025

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/semenov-2025/"><img src="https://encorescience.org/badge/papers/semenov-2025.svg" alt="Encore: 2 findings reproduced, Semenov et al. 2025"></a>

Or as Markdown:

[![Encore: 2 findings reproduced, Semenov et al. 2025](https://encorescience.org/badge/papers/semenov-2025.svg)](https://encorescience.org/papers/semenov-2025/)

The same numbers are in this page’s JSON, under badge (how it is counted).