Papers / Semenov et al. 2026

Semenov et al. 2026 · Bioelectrochemistry

Sub-microsecond optical measurements of cell membrane charging and lesioning by pulsed electric fields

Iurii Semenov, Giedrė Šilkūnienė, Mantas Šilkūnas, Olga N. Pakhomova, Joel N. Bixler, Bennett L. Ibey, Peter Kochunov, Andrei G. Pakhomov

Outcomes of 211 claims

  • 11 reproduced
  • 12 partially reproduced
  • 26 not reproduced
  • 162 blocked

Summary, DANDI:001515: Almost none of the paper's findings could be tested here, and none was shown to fail. The dandiset holds FluoVolt time courses of single 1-us pulses, not the paper's Di-8-ANEPPS and FluoVolt escalation sets, so the polarization pattern, the loss of pole charging at electroporating fields, and the Gd3+, calcium and two-pulse resealing results could not be tested. The one claim needing no recordings, the effect of membrane conductivity on charging, partly held: the 100-fold value matches, but a 10-fold rise gives 1.3% where the paper says about 2%.

Summary, DANDI:001516: Almost none of the paper's findings could be tested in this data, and the one that could be tested did not match the paper's text. The dandiset holds a FluoVolt two-pulse experiment the paper does not report, not the Di-8-ANEPPS recordings behind its loss of pole charging at high fields, the Gd3+ extension of anodic charging, the calcium entry or the membrane recovery after a conditioning pulse. Those findings could not be tested for lack of data. The only claim needing no recordings, that a modest rise in membrane conductivity cuts charging by about 2%, gave 1.33% from the paper's own equation and constants. The larger-rise value agreed.

Summary, DANDI:001517: The pole dimming at high fields, the Di-8-ANEPPS rise up to 570 V/cm and the within-set decline from 1000 V/cm held, but the dye saturation limits and the equator following the cosine law did not. FluoVolt peaked at 49% cathodic dF against the paper's 66%. The likeliest reason is the background region, which the paper does not place and which shifts pole dF up to threefold. Gd3+, calcium, 0.3-us and two-pulse findings could not be tested because those recordings are not in the dataset. Charging below linear scaling held only with generator volts matched in order to the paper's V/cm.

Summary, DANDI:001518: Most of the paper's main findings did not hold in this data or could not be tested. The Gd3+ effects, calcium responses, two-pulse recovery and 0.3-us pulses could not be tested because the dandiset lacks those experiments. The dye response ceilings (FluoVolt peaked at 36% against 71%), the dye calibration, the pole dimming and the cosine behaviour near the equator did not reproduce. These tests assume a volts to V/cm conversion that the files and paper do not give, though the ceilings fail at every conversion tried. Only the within-set decline of Di-8-ANEPPS response reproduced, mostly as a drift present at every field strength.

Summary, DANDI:001521: Most of the paper's main findings, the optical measurements of membrane charging and pole leakage with voltage-sensitive dyes, could not be tested, because this dandiset holds only Fluo-4 calcium imaging. Of the calcium findings, clear Ca2+ entry after a single pulse at 1000 and 1200 V/cm held, though the effect is small. The signal staying elevated through 5 minutes did not hold, because unpulsed cells lose about 12% of their signal, which the paper's figure does not show. The strong response in 28% of cells at 780 V/cm with pulse trains did not reproduce either. The records give no way to match the paper's cell counts, since the cells were recorded repeatedly. A minor conductivity calculation matched only in part.

Summary, DANDI:001525: The paper's membrane recovery findings mostly hold in this data, which covers only its two-pulse experiment, so most other findings could not be tested. Test-pulse charging stays cosine-shaped and unchanged after mild conditioning pulses and falls after the strongest ones, as reported. The fall differs in size from the paper's at the cathodic pole, and at the anodic pole it is not significant after the weaker of the two strongest pulses. Full resealing after mild pulses and residual leak after strong ones hold, but the test pulse also finds a pole difference after the strongest pulse. These results depend on an automatic membrane trace, and the dye calibration, escalation, Gd3+ and calcium findings are absent from the dataset.

Summary, DANDI:001526: Few of the paper's findings could be tested, and none held up cleanly. The dandiset holds only the Di-8-ANEPPS alternating-field and short-pulse experiments, so the FluoVolt, Gd3+, calcium and two-pulse recovery findings could not be tested. Stable responses before electroporation did not reproduce, and the lasting drop afterwards was larger than reported, both depending on an undescribed background subtraction and on which cells the paper used. The fall in polarization within a set at the electroporating field held only under one background choice made after seeing results. The maximum polarization with short pulses reached 34.9% against the reported 53%.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to an attempt

Attempts 7

7 current

Every attempt on the paper, each with the datasets it used and their versions. An attempt on a dataset replaces the one before it on that dataset; the paper’s page shows the current ones.

  1. Attempt 012026-11-02current
    DANDI:001515 version 0.261006.1841
    34 claims · 8 findings about the data · protocol pilot-13
  2. Attempt 022026-11-02current
    DANDI:001516 version 0.261006.1833
    32 claims · 9 findings about the data · protocol pilot-13
  3. Attempt 032026-11-02current
    DANDI:001517 version 0.261006.1856
    31 claims · 7 findings about the data · protocol pilot-13
  4. Attempt 042026-11-02current
    DANDI:001518 version 0.261006.1957
    30 claims · 6 findings about the data · protocol pilot-13
  5. Attempt 052026-11-02current
    DANDI:001521 version 0.261006.1845
    27 claims · 6 findings about the data · protocol pilot-13
  6. Attempt 062026-11-02current
    DANDI:001525 version 0.261006.1856
    27 claims · 8 findings about the data · protocol pilot-13
  7. Attempt 072026-11-02current
    DANDI:001526 version 0.261006.1851
    30 claims · 9 findings about the data · protocol pilot-13

Claims

Attempt semenov-2026-01, on DANDI:001515 version 0.261006.1841

Semenov et al. (2026) on dandiset 001515 34 Open in Colab

Partially reproduced1

  • Partially reproduced

    By Eq. (2), the effective membrane conductivity barely affects charging while it stays far below cytosol and medium conductivities; a 10-fold rise reduces IMP by about 2% and a 100-fold rise by 12%.

    Eq. (2) with the constants of Methods 2.3 gives an IMP reduction of 1.33% (reading a, 1 - f/1.5) or 1.20%…

    Figure 5B; Results 3.5, paragraph 3fig5b-conductivity-calibration
    From the paper

    its 10-fold increase would go unnoticed, yielding just a ~2% IMP reduction, and a 100-fold increase would reduce IMP by just 12%.

    Result

    Eq. (2) with the constants of Methods 2.3 gives an IMP reduction of 1.33% (reading a, 1 - f/1.5) or 1.20% (reading b, relative to f at 3e-7 S/m) for a 10-fold rise of membrane conductivity, outside 2 +- 0.2%, and 11.87% (a) or 11.75% (b) for a 100-fold rise, inside 12 +- 1.2%. Both readings give the same result. The qualitative part of the statement holds, as a 1000-fold rise is needed to reduce IMP by more than half (57.4%). In a grid of radii 5 to 15 um and membrane thicknesses 3 to 7 nm (a variant, not the criterion), no combination puts both values within tolerance under reading (a); R = 8 um with d = 3 nm gives 2.19% and 18.3%. The computation uses no recordings.

    Deviations from the paper’s method
    • None in method; Eq. (2) and its constants are those of Methods 2.3, and both readings of the criterion were run.

Blocked33

  • Blocked

    Below and near the electroporation threshold (43 to 570 V/cm, 1-us pulses), the membrane depolarizes at the cathode-facing pole and hyperpolarizes at the anode-facing pole, polarization decreases from the poles towards the equator, and it scales proportionally with field strength, as the Schwan equation describes.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 1, 43 to 570 V/cm; Results 3.1, paragraph 1fig1-schwan-pattern
    From the paper

    Electric pulses below and near the electroporation threshold produce a well-known spatial pattern of membrane polarization, such as in Fig. 1, 43–570 V/cm. The membrane depolarizes at the cathode-facing membrane pole and hyperpolarizes at the opposite, anode-facing pole. Polarization gradually decreases from the poles towards the cell equator, and scales up proportionally with the electric field strength

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    With Di-8-ANEPPS and 1-us pulses, polarization grows with field strength up to 570 V/cm; at 780 V/cm the cathodic pole stops increasing and dims, and at 1000 to 1400 V/cm the poles show reduced or absent polarization while regions nearer the equator stay polarized and may polarize more than the poles.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 1 and its legend; Results 3.1, paragraph 1fig1-pole-dimming
    From the paper

    At a higher electric field strength of 780 V/cm, polarization at the cathodic pole does not further increase but dims out, indicating a less efficient charging of the partially permeabilized membrane. Still stronger electric fields produce a distinct pattern of reduced or absent polarization at the poles ... while regions closer to the equator remain relatively intact and may polarize more than the poles

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    With FluoVolt, pole dF rose with field strength until it saturated at 66% (255 mV) at 360 V/cm at the cathodic pole and -83% (-320 mV) at 570 V/cm at the anodic pole; stronger fields did not increase the anodic response and decreased the cathodic one.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 2A; Results 3.2, paragraph 2fig2a-fluovolt-saturation
    From the paper

    ΔF increased proportionally to the electric field strength until reaching apparent saturation at 66% ΔF (255 mV IMP) at 360 V/cm at the cathodic pole, and −83% ΔF (−320 mV IMP) at 570 V/cm at the anodic pole. Further escalation of the electric field strength did not increase the dye response at the anodic pole and even decreased it at the cathodic pole.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the FluoVolt experiments of the paper, sets of 40 baseline and 60 pulse images at 900 ns into 1-us pulses with the field escalated from 43 to 1400 V/cm within each cell (n = 4); no file has that structure, and no cell is exposed to more than one amplitude. Using the dandiset's time courses in their place would also need the delay of each frame (to find the 900-ns frame) and the field strength in V/cm (the paper's comes from a Sim4Life model of 1.6-mm electrodes), neither of which the files record, so this is also metadata_insufficient. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    FluoVolt measurements were stable without pulses (no significant bleaching or photosensitization), and the response within each set stayed stable through the 60 pulses, even at 1000 V/cm and above.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 2A; Results 3.2, paragraph 2question to the readerfig2a-fluovolt-stable
    From the paper

    Without PEF (first 40 datapoints, or ~ 7 s in each set), measurements were stable, indicating no significant photosensitization or dye bleaching ... but the dye response in each set stayed stable through the 60 pulses applied

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the FluoVolt experiments of the paper, sets of 40 baseline and 60 pulse images at 900 ns into 1-us pulses with the field escalated from 43 to 1400 V/cm within each cell (n = 4); no file has that structure, and no cell is exposed to more than one amplitude. Using the dandiset's time courses in their place would also need the delay of each frame (to find the 900-ns frame) and the field strength in V/cm (the paper's comes from a Sim4Life model of 1.6-mm electrodes), neither of which the files record, so this is also metadata_insufficient. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Di-8-ANEPPS dF kept increasing with field strength up to 570 V/cm at both poles.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 2B; Results 3.2, paragraph 3fig2b-di8-climbs-to-570
    From the paper

    This dye has a lower sensitivity to membrane polarization (note the vertical scale different from Fig. 2A), but ΔF kept climbing up to the electric field strength of 570 V/cm at both cell poles.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Di-8-ANEPPS responses were somewhat affected by bleaching, most visibly at 43 V/cm, where bleaching added about 5% to dF at the anodic pole and took about 5% from it at the cathodic pole.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 2B; Results 3.2, paragraph 3fig2b-di8-bleaching
    From the paper

    The responses were somewhat affected by dye bleaching (particularly noticeable at 43 V/cm, where bleaching added ~5% to ΔF at the anodic pole and reduced it by the same ~5% at the cathodic pole.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    With Di-8-ANEPPS, responses to pulses of 780 V/cm and above decreased gradually within each set of 60 images.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 2B; Results 3.2, paragraph 3fig2b-di8-decline-within-set
    From the paper

    In addition, responses to PEFs at and above 780 V/cm decreased gradually in each set of 60 images, consistent with expectations of adding membrane damage by additional electroporation pulses in each set

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Repeated alternating sets at 150 and 230 V/cm (480 pulses and 800 flashes) gave dF responses constant within and between sets.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 2C and 2D; Results 3.2, paragraph 4fig2cd-stable-before-electroporation
    From the paper

    Repeated sets of PEFs at 150 and 230 V/cm, delivered in alternation, produced ΔF responses that stayed constant both within each set and between the sets (Fig. 2C and D).

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    At 1000 V/cm the cathodic pole dF fell from 40 +- 10% at the start of the set to 26.6 +- 8% at its end, a trend that was not statistically significant.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 2C; Results 3.2, paragraph 4fig2c-1000-within-set
    From the paper

    In contrast, at an electroporating field strength of 1000 V/cm, ΔF at the cathodic pole decreased from 40 ± 10% at the beginning of the set to 26.6 ± 8% at the end of it. Although not statistically significant (p > 0.05)

    Reported statistics
    • 2-tailed paired t-test (named in the Fig. 2 legend), p > 0.05 (n = 8 cells)
    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Set-averaged dF stayed nearly constant before the 1000 V/cm exposure but was about 20% lower in the sets after it.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 2D and legend; Results 3.2, paragraph 4question to the readerfig2d-lasting-reduction
    From the paper

    ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05).

    Reported statistics
    • 2-tailed paired t-test, p < 0.05 (n = 8 cells)
    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Fitted linearly through the origin over -150 to +150 mV IMPC, FluoVolt changes by 26% and Di-8-ANEPPS by 9.1% dF per 100 mV, with correlation coefficients 0.96 and 0.78.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 3 and legend; Results 3.3, paragraph 1uses data from outside the datasetfig3-dye-sensitivity
    From the paper

    The correlation coefficients of the fits equaled 0.96 for FluoVolt and 0.78 for Di-8 ANEPPS (due to a lower signal-to-noise ratio), with respective slope coefficients of 26% and 9.1% ΔF per 100 mV of IMP.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the FluoVolt experiments of the paper, sets of 40 baseline and 60 pulse images at 900 ns into 1-us pulses with the field escalated from 43 to 1400 V/cm within each cell (n = 4); no file has that structure, and no cell is exposed to more than one amplitude. Using the dandiset's time courses in their place would also need the delay of each frame (to find the 900-ns frame) and the field strength in V/cm (the paper's comes from a Sim4Life model of 1.6-mm electrodes), neither of which the files record, so this is also metadata_insufficient. The claim also needs the tau-against-radius fit of reference [20], not reconstructed here. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    FluoVolt departed from linearity from about +-200 mV IMPC, while Di-8-ANEPPS stayed nearly linear from -500 to +500 mV; so FluoVolt's early departure reflects its dynamic range, not electroporation.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 3 and legend; Results 3.3, paragraph 1uses data from outside the datasetfig3-fluovolt-nonlinear
    From the paper

    The actual measurements with FluoVolt gradually became non-linear already at ±200 mV, while those for Di-8-ANEPPS stayed essentially linear throughout the tested range from −500 to +500 mV.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the FluoVolt experiments of the paper, sets of 40 baseline and 60 pulse images at 900 ns into 1-us pulses with the field escalated from 43 to 1400 V/cm within each cell (n = 4); no file has that structure, and no cell is exposed to more than one amplitude. Using the dandiset's time courses in their place would also need the delay of each frame (to find the 900-ns frame) and the field strength in V/cm (the paper's comes from a Sim4Life model of 1.6-mm electrodes), neither of which the files record, so this is also metadata_insufficient. The claim also needs the tau-against-radius fit of reference [20], not reconstructed here. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    FluoVolt measured and calculated IMP matched only at 43 and 150 V/cm; with stronger 1-us pulses the pole dF peaked at 71 +- 10% (cathodic) and -83.5 +- 5% (anodic), about +260 and -330 mV.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 4A; Results 3.4, paragraph 1uses data from outside the datasetfig4a-fluovolt-limits
    From the paper

    However, this assumption held only for the applied fields of 43 and 150 V/cm, where measured and calculated IMP matched. With stronger PEFs, maximum ΔF reached 71 ± 10% and −83.5 ± 5% at the cathodic and anodic poles, respectively.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the FluoVolt experiments of the paper, sets of 40 baseline and 60 pulse images at 900 ns into 1-us pulses with the field escalated from 43 to 1400 V/cm within each cell (n = 4); no file has that structure, and no cell is exposed to more than one amplitude. Using the dandiset's time courses in their place would also need the delay of each frame (to find the 900-ns frame) and the field strength in V/cm (the paper's comes from a Sim4Life model of 1.6-mm electrodes), neither of which the files record, so this is also metadata_insufficient. The claim also needs the tau-against-radius fit of reference [20], not reconstructed here. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    FluoVolt cathodic polarization fell from 71% at 360 V/cm to 45 to 50% at 1000 to 1400 V/cm.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 4A; Results 3.4, paragraph 1fig4a-fluovolt-cathodic-decline
    From the paper

    Notably, polarization at the cathodic pole decreased from 71% at 360 V/cm to 45–50% at 1000–1400 V/cm, indicating that the more severe membrane damage prevented its polarization to the maximum.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the FluoVolt experiments of the paper, sets of 40 baseline and 60 pulse images at 900 ns into 1-us pulses with the field escalated from 43 to 1400 V/cm within each cell (n = 4); no file has that structure, and no cell is exposed to more than one amplitude. Using the dandiset's time courses in their place would also need the delay of each frame (to find the 900-ns frame) and the field strength in V/cm (the paper's comes from a Sim4Life model of 1.6-mm electrodes), neither of which the files record, so this is also metadata_insufficient. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    With Di-8-ANEPPS and 1-us pulses, measured IMP fell below the calculated value at 570 V/cm, where dF peaked at 57 +- 14% (cathodic) and -55 +- 4% (anodic), over 600 mV.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 4B; Results 3.4, paragraph 2uses data from outside the datasetfig4b-di8-limits
    From the paper

    The measured IMP decreased below the calculated value when the electric field reached 570 V/cm, concurrently with reaching the maximum ΔF of 57 ± 14% at the cathodic pole and − 55 ± 4% at the anodic pole. These values corresponded to membrane polarization by over 600 mV, which is twice the value measured with FluoVolt.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Averaged over only the first 10 of the 60 pulses, Di-8-ANEPPS cathodic polarization reached 66 +- 15% (710 +- 200 mV), so the 600-mV maximum is not the dye's limit.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 4B, dotted lines; Results 3.4, paragraph 3fig4b-first-10-pulses
    From the paper

    Polarization measured this way reached 66 ± 15% (710 ± 200 mV) at the cathodic pole, suggesting that the 600-mV maximum, averaged from 60 PEFs, was not the dye limit but the actual IMP

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Above 780 V/cm the pole IMP fell progressively with field strength, more at the cathodic pole; at 1400 V/cm the cathodic pole no longer charged and the anodic pole fell to about -30% dF (-330 mV).

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 4B; Results 3.4, paragraph 4fig4b-cathodic-asymmetry
    From the paper

    As the electric field increased further, the IMP reached at the poles progressively decreased, and the reduction was more pronounced at the cathodic pole ... At 1400 V/cm, charging was no longer detectable at the cathodic pole (i.e., the membrane became fully permeable) and dropped to ~30% ΔF (~ −330 mV) at the anodic pole.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    At the apparent electroporation threshold of 570 V/cm and at 780 V/cm, permeabilization judged by the shortfall from the calculated IMP was about the same at the two poles.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 4B; Results 3.4, paragraph 4uses data from outside the datasetfig4b-poles-alike-570-780
    From the paper

    At the apparent electroporation threshold of 570 V/cm, as well as with a more intense exposure at 780 V/cm, permeabilization at both poles (judged by the difference from the theoretical values) was approximately the same.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Membrane regions nearer the equator were unaffected by pole electroporation and followed the cosine dependence of the Schwan equation up to 1000 V/cm.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 4C and legend; Results 3.4, paragraph 4uses data from outside the datasetfig4c-equator-follows-cosine
    From the paper

    Membrane areas closer to the equator ... appeared relatively unaffected and followed the cosine dependence predicted by Schwan formula up to 1000 V/cm (Fig. 4C).

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings; every file is FluoVolt. It also needs the paper's escalation sets of 40 baseline and 60 pulse images at 900 ns, which no file has. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    With 0.3-us pulses at higher fields (357 to 3320 V/cm), imaged at 275 ns, the maximum dF was 53 +- 4% (about 600 mV) at both poles, as with 1-us pulses, and the response changed with field strength in the same way.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 4D; Results 3.4, paragraph 5fig4d-short-pulses-same-limit
    From the paper

    Contrary to the expectations, the results were similar to those with 1-μs pulses in Fig. 4B: the maximum ΔF reached was 53 ± 4% (~600 mV) at both cell poles. The pattern of how the response changed with increasing PEF strength was not different from that with 1-μs PEFs either.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Di-8-ANEPPS recordings with 0.3-us pulses imaged at 275 ns; every file is FluoVolt with 1-us pulses. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    With 1 mM Gd3+ the anodic pole charged to -864 +- 44 mV, against -542 +- 57 mV in parallel controls (p < 0.001).

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 1fig5a-gd-extends-anodic
    From the paper

    Indeed, we found that 1 mM Gd3+ extended the range of membrane charging at the anodic pole down to −864 ± 44 mV (p < 0.001 compared to −542 ± 57 mV in parallel control experiments, Fig. 5A).

    Reported statistics
    • 2-tailed t-test (Fig. 5 legend), p < 0.001 (n = 7 cells with Gd3+, 5 control cells)
    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the Di-8-ANEPPS series with 1 mM Gd3+ (n = 7) and parallel controls (n = 5); no file is Di-8-ANEPPS and no session description names Gd3+. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    With Gd3+, the measured IMP stayed nearly identical to IMPC down to -780 mV, so the Di-8-ANEPPS calibration holds at high IMPs.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 1uses data from outside the datasetfig5a-gd-linear
    From the paper

    Furthermore, measured IMP remained nearly identical to the theoretical IMPC down to −780 mV, indicating that the dye response remained linear and its calibration was valid even at high IMPs.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the Di-8-ANEPPS series with 1 mM Gd3+ (n = 7) and parallel controls (n = 5); no file is Di-8-ANEPPS and no session description names Gd3+. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    At the cathodic pole Gd3+ cells reached 647 +- 44 mV, not significantly above controls, but Gd3+ prevented the decline of IMP with stronger fields.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 2fig5a-gd-cathodic
    From the paper

    At the cathodic pole, polarization in the presence of Gd3+ reached 647 ± 44 mV, a value not significantly higher than that in the control group without Gd3+. However, Gd3+ prevented the progressive decline in IMP as the electric field was increased.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the Di-8-ANEPPS series with 1 mM Gd3+ (n = 7) and parallel controls (n = 5); no file is Di-8-ANEPPS and no session description names Gd3+. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Gd3+ and control data differ significantly for datapoints with IMPC below -700 mV and above 1200 mV.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 5A legenduses data from outside the datasetfig5a-gd-differences
    From the paper

    Differences between Gd3+ and control group data are significant at p < 0.05 or better (2-tailed t-test) for datapoints below −700 mV and above 1200 mV.

    Reported statistics
    • 2-tailed t-test, p < 0.05 (n = 7 cells with Gd3+, 5 control cells)
    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the Di-8-ANEPPS series with 1 mM Gd3+ (n = 7) and parallel controls (n = 5); no file is Di-8-ANEPPS and no session description names Gd3+. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    For most datapoints, Gd3+ reduced the electroporation-induced effective membrane conductivity 2 to 3-fold.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 5C; Results 3.5, paragraph 4uses data from outside the datasetfig5c-gd-reduces-conductivity
    From the paper

    For most datapoints, Gd3+ reduced the electroporation- induced effective conductivity 2–3-fold.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the Di-8-ANEPPS series with 1 mM Gd3+ (n = 7) and parallel controls (n = 5); no file is Di-8-ANEPPS and no session description names Gd3+. Its dependency fig5b-conductivity-calibration was tested (partially reproduced), but the measured IMPs it converts are not in the dandiset. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    A single 1-us pulse caused clear Ca2+ entry at 1000 and 1200 V/cm, with the signal elevated through 5 min; the small rise at 780 V/cm was not significant.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 6A; Results 3.6, paragraph 2fig6a-ca-single-pulse
    From the paper

    Exposure to a single 1-μs pulse at escalating field strengths, from 0 to 1200 V/cm established a clear peak of Ca2+ entry at 1000 and 1200 V/ cm, and Ca2+ signal remained elevated through the 5-min observation period (Fig. 6A). A subtle ΔF increase after exposure at 780 V/cm was at the detection limit and not statistically significant.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Fluo-4 Ca2+ imaging (images every 1 or 2 s for 150 s or 5 min); no file holds Ca2+ imaging, and every file is 70 strobe frames of FluoVolt. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    After a train of sixty 1-us pulses at 6 Hz, 28% of cells responded strongly at 780 V/cm and nearly all at higher field strengths.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 6B; Results 3.6, paragraph 3fig6b-ca-train-responders
    From the paper

    A strong Ca2+ response was recorded in 28% of cells exposed at 780 V/cm and in nearly all cells at higher intensities (Fig. 6B).

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Fluo-4 Ca2+ imaging (images every 1 or 2 s for 150 s or 5 min); no file holds Ca2+ imaging, and every file is 70 strobe frames of FluoVolt. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    At 650 V/cm only 2 cells (5.9%) responded strongly, yet the mean Ca2+ signal at the end of recording differed from zero (p < 0.001) and was marginally higher than at 230 V/cm (p < 0.05).

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 6B; Results 3.6, paragraph 3fig6b-ca-650
    From the paper

    At 650 V/cm, only 2 cells (5.9%) showed a strong response, but the mean Ca2+ signal by the end of recording was significantly different from zero (p < 0.001, one sample t-test) and marginally higher than after exposure at 230 V/cm (p < 0.05, single-tailed t-test).

    Reported statistics
    • 650 V/cm mean signal at the end of recording against zero: one sample t-test, p < 0.001 (n = about 34 cells (2 cells are 5.9%))
    • 650 against 230 V/cm: single-tailed t-test, p < 0.05
    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs Fluo-4 Ca2+ imaging (images every 1 or 2 s for 150 s or 5 min); no file holds Ca2+ imaging, and every file is 70 strobe frames of FluoVolt. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    The azimuthal profile of a 150 V/cm test pulse given 5 us after a conditioning pulse kept the cosine shape of an undamaged membrane after conditioning pulses up to 1000 V/cm, while after 1200 and 1400 V/cm charging at the poles was markedly reduced.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 7A and legend; Results 3.7, paragraph 3question to the readerfig7a-cosine-profiles
    From the paper

    Polarization still followed a cosine function after conditioning PEFs of up to 1000 V/cm. However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles, indicating a persistent membrane permeabilization.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the two-pulse Di-8-ANEPPS recordings (a conditioning pulse, then a 150 V/cm test pulse 5 us later); every file is FluoVolt with a single pulse. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Normalized to 150 V/cm, pole polarization during the conditioning pulse fell 1.5 times below linear scaling at 560 V/cm and 2-fold at 760 V/cm, and further at stronger fields (p < 0.01 for every point from 560 V/cm).

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 7B, top panels; Results 3.7, paragraph 5fig7b-charging-during-pulse
    From the paper

    Actual measurements fell 1.5 times below this line for 560 V/cm PEFs, 2- fold for 760 V/cm PEFs, and diverged further for more intense PEFs (p < 0.01 for all datapoints ≥560 V/cm, one sample t-test).

    Reported statistics
    • one sample t-test, p < 0.01 (n = 5 cells)
    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim uses the Fig. 4B Di-8-ANEPPS escalation data (Results 3.7, paragraph 4), and depends on fig4b-di8-limits, blocked for the same reason; every file is FluoVolt. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    A 150 V/cm test pulse 5 us after the conditioning pulse charged the poles as in undamaged cells after conditioning up to 760 V/cm, to about 80% (not significant) after 1000 V/cm, and to about 70% and 50% after 1200 and 1400 V/cm, a persistent permeabilization.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 7A and 7B, bottom panels; Results 3.7, paragraphs 3 and 5fig7ab-test-pulse-recovery
    From the paper

    However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles, indicating a persistent membrane permeabilization ... In contrast, measurements 6 μs later (test pulse) did not differ from the control up to 760 V/cm strength of the conditioning PEF; they were at ~80% of the control reading after 1000 V/cm conditioning PEF but the difference was not statistically significant. Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test).

    Reported statistics
    • 1200 V/cm conditioning, test pulse against control: two-sided t-test, p < 0.05 (n = 5 cells)
    • 1400 V/cm conditioning, test pulse against control: two-sided t-test, p < 0.01 (n = 5 cells)
    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the two-pulse Di-8-ANEPPS recordings (a conditioning pulse, then a 150 V/cm test pulse 5 us later); every file is FluoVolt with a single pulse. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    Within 6 us of the electroporating pulse, effective membrane conductivity at the poles fell by a factor of about 10 (range 7 to 20) for most datapoints; the cathodic pole, more conductive during the pulse, no longer differed from the anodic pole at the test pulse.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 7C; Results 3.7, paragraph 7fig7c-fast-conductivity-drop
    From the paper

    Fig. 7C shows a profound reduction in the λm,eff within just 6 μs after the electroporating pulse. For most datapoints, it dropped by a factor of 10 (range: 7–20). While the cathodic pole became more conductive than the anodic pole during the electroporating pulse ... no difference between the poles was detected by the test pulse.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the two-pulse Di-8-ANEPPS recordings (a conditioning pulse, then a 150 V/cm test pulse 5 us later); every file is FluoVolt with a single pulse. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

  • Blocked

    After mildly electroporating 570 and 760 V/cm pulses the membrane resealed fully within 6 us; after stronger pulses a residual conductivity increase persisted.

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude…

    Data missing from the datasetFigure 7C; Results 3.7, paragraph 7fig7c-full-reseal-mild
    From the paper

    For mildly electroporating PEFs of 570 and 760 V/cm, membrane resealed fully (within the accuracy of measurements) within just 6 μs. With more intense PEFs, the residual increased conductivity persisted for at least 6 μs, indicating the formation of more stable membrane lesions.

    Result

    The dandiset holds 292 files of FluoVolt strobe-imaging time courses (70 frames each, one 1-us pulse amplitude per subject, 20 to 100 V across electrodes 1.00 mm apart, frame delays not recorded). The claim needs the two-pulse Di-8-ANEPPS recordings (a conditioning pulse, then a 150 V/cm test pulse 5 us later); every file is FluoVolt with a single pulse. Dandisets 001516, 001517 and 001518 also name this paper and may hold these data; they are separate targets of the registry and were not read here.

Attempt semenov-2026-02, on DANDI:001516 version 0.261006.1833

Reproducing Semenov et al. (2026) from dandiset 001516 1 Open in Colab

Not reproduced1

  • Not reproduced

    By Eq. (2), the effective membrane conductivity barely affects charging while it stays far below cytosol and medium conductivities; a 10-fold rise reduces IMP by about 2% and a 100-fold rise by 12%.

    Eq. (2) with the constants of Methods 2.3 gives f = 1.49798 for the intact membrane.

    Figure 5B; Results 3.5, paragraph 3fig5b-conductivity-calibration
    From the paper

    its 10-fold increase would go unnoticed, yielding just a ~2% IMP reduction, and a 100-fold increase would reduce IMP by just 12%.

    Result

    Eq. (2) with the constants of Methods 2.3 gives f = 1.49798 for the intact membrane. A 10-fold rise in effective conductivity reduces IMP by 1.33% under reading (a), 1 - f/1.5, and by 1.20% under reading (b), relative to the intact f, both outside 2 +- 0.2%. A 100-fold rise gives 11.87% and 11.75%, within 12 +- 1.2%. A 2% reduction needs a 15.2-fold (a) or 16.2-fold (b) rise. With other radii and membrane thicknesses (5 to 12 um, 4 to 7 nm; a variant, not the criterion) the 10-fold reduction is 0.60 to 2.46%, within 2 +- 0.2% only for 10 um with 4 nm (2.06%) or 12 um with 5 nm (1.98%). The claim uses no recordings, so the outcome says nothing about the dataset. The notebook prints the Eq. (2) curve at 1 to 100000-fold (measured IMP 98.67% of IMPC at 10-fold, 88.13% at 100-fold, 42.62% at 1000-fold, 6.91% at 10000-fold) for comparison with the curve of Fig. 5B; it does not read the figure.

Not tested in a notebook 31

31 data missing from the dataset

Blocked31

  • Blocked

    With Di-8-ANEPPS and 1-us pulses, polarization grows with field strength up to 570 V/cm; at 780 V/cm the cathodic pole stops increasing and dims, and at 1000 to 1400 V/cm the poles show reduced or absent polarization while regions nearer the equator stay polarized and may polarize more than the poles.

    The criterion uses the Di-8-ANEPPS 1-us escalation cells of Fig. 4B (n = 5).

    Data missing from the datasetFigure 1 and its legend; Results 3.1, paragraph 1fig1-pole-dimming
    From the paper

    At a higher electric field strength of 780 V/cm, polarization at the cathodic pole does not further increase but dims out, indicating a less efficient charging of the partially permeabilized membrane. Still stronger electric fields produce a distinct pattern of reduced or absent polarization at the poles ... while regions closer to the equator remain relatively intact and may polarize more than the poles

    Result

    The criterion uses the Di-8-ANEPPS 1-us escalation cells of Fig. 4B (n = 5). Every file of the dandiset names FluoVolt, and none holds a 1-us escalation over 43 to 1400 V/cm in sets of 40 and 60 images; the dandiset holds a FluoVolt two-pulse experiment the paper does not report (notebook, data check). Dandisets 001517 and 001518, separate targets with their own claims files, are titled as Di-8-ANEPPS and dye-comparison experiments of the same lab and were not used here.

  • Blocked

    With FluoVolt, pole dF rose with field strength until it saturated at 66% (255 mV) at 360 V/cm at the cathodic pole and -83% (-320 mV) at 570 V/cm at the anodic pole; stronger fields did not increase the anodic response and decreased the cathodic one.

    Needs the FluoVolt escalation of Fig. 2A (n = 4, 43 to 1400 V/cm, 40 baseline and 60 pulse images, with values…

    Data missing from the datasetFigure 2A; Results 3.2, paragraph 2fig2a-fluovolt-saturation
    From the paper

    ΔF increased proportionally to the electric field strength until reaching apparent saturation at 66% ΔF (255 mV IMP) at 360 V/cm at the cathodic pole, and −83% ΔF (−320 mV IMP) at 570 V/cm at the anodic pole. Further escalation of the electric field strength did not increase the dye response at the anodic pole and even decreased it at the cathodic pole.

    Result

    Needs the FluoVolt escalation of Fig. 2A (n = 4, 43 to 1400 V/cm, 40 baseline and 60 pulse images, with values at 360 and 570 V/cm). The dandiset's only FluoVolt single-pulse sets are two fields of view (c6, c7) at 150, 520, 900, 1270 and 1570 V/cm with 1.00-mm electrodes and 20 and 40 frames, which are not these recordings and have neither 360 nor 570 V/cm. Measured with the paper's method as a variant (no outcome, 4 cells), their pole response with the uniform offset removed is 14.3 to 15.6% at the cathodic pole at 150, 520 and 1570 V/cm and 7.0 to 9.0% at 900 and 1270 V/cm, and peaks at -23.2% at the anodic pole at 520 V/cm.

  • Blocked

    FluoVolt measurements were stable without pulses (no significant bleaching or photosensitization), and the response within each set stayed stable through the 60 pulses, even at 1000 V/cm and above.

    Needs the Fig. 2A FluoVolt escalation cells (n = 4) at 1000 to 1400 V/cm, which are not in the dandiset (see…

    Data missing from the datasetFigure 2A; Results 3.2, paragraph 2question to the readerfig2a-fluovolt-stable
    From the paper

    Without PEF (first 40 datapoints, or ~ 7 s in each set), measurements were stable, indicating no significant photosensitization or dye bleaching ... but the dye response in each set stayed stable through the 60 pulses applied

    Result

    Needs the Fig. 2A FluoVolt escalation cells (n = 4) at 1000 to 1400 V/cm, which are not in the dandiset (see fig2a-fluovolt-saturation). As a variant on the dandiset's own single-pulse sets (c6, c7; 4 cells; no outcome), the criterion's comparison gives a fall of the per-frame pole dF within the 40 pulse frames at 1270 and 1570 V/cm of 2.9 to 11.1 points under reading (b) (3 of 4 pole-sets at p < 0.05) and 3.8 to 24.0 points under reading (a) (1 of 4), and in the sham set a fall of 12.1 and 12.2 points in the pulse frames and 15.9 and 16.3 points in the baseline (frames 1-9 against 10-19) with no pulse. By the claim's rule these recordings would give not reproduced; they are not the paper's cells.

  • Blocked

    Di-8-ANEPPS dF kept increasing with field strength up to 570 V/cm at both poles.

    Needs the Di-8-ANEPPS escalation of Fig. 2B (n = 5); all 72 files of the dandiset name FluoVolt.

    Data missing from the datasetFigure 2B; Results 3.2, paragraph 3fig2b-di8-climbs-to-570
    From the paper

    This dye has a lower sensitivity to membrane polarization (note the vertical scale different from Fig. 2A), but ΔF kept climbing up to the electric field strength of 570 V/cm at both cell poles.

    Result

    Needs the Di-8-ANEPPS escalation of Fig. 2B (n = 5); all 72 files of the dandiset name FluoVolt.

  • Blocked

    Di-8-ANEPPS responses were somewhat affected by bleaching, most visibly at 43 V/cm, where bleaching added about 5% to dF at the anodic pole and took about 5% from it at the cathodic pole.

    Needs the Di-8-ANEPPS 43 V/cm sets of Fig. 2B; the dandiset holds no Di-8-ANEPPS recording and no 43 V/cm set.

    Data missing from the datasetFigure 2B; Results 3.2, paragraph 3fig2b-di8-bleaching
    From the paper

    The responses were somewhat affected by dye bleaching (particularly noticeable at 43 V/cm, where bleaching added ~5% to ΔF at the anodic pole and reduced it by the same ~5% at the cathodic pole.

    Result

    Needs the Di-8-ANEPPS 43 V/cm sets of Fig. 2B; the dandiset holds no Di-8-ANEPPS recording and no 43 V/cm set.

  • Blocked

    With Di-8-ANEPPS, responses to pulses of 780 V/cm and above decreased gradually within each set of 60 images.

    Needs the Di-8-ANEPPS sets of Fig. 2B at 780 to 1400 V/cm; not in the dandiset.

    Data missing from the datasetFigure 2B; Results 3.2, paragraph 3fig2b-di8-decline-within-set
    From the paper

    In addition, responses to PEFs at and above 780 V/cm decreased gradually in each set of 60 images, consistent with expectations of adding membrane damage by additional electroporation pulses in each set

    Result

    Needs the Di-8-ANEPPS sets of Fig. 2B at 780 to 1400 V/cm; not in the dandiset.

  • Blocked

    Repeated alternating sets at 150 and 230 V/cm (480 pulses and 800 flashes) gave dF responses constant within and between sets.

    Needs the Di-8-ANEPPS alternation of 150 and 230 V/cm sets of Fig. 2C and D (n = 8); the dandiset holds no…

    Data missing from the datasetFigure 2C and 2D; Results 3.2, paragraph 4fig2cd-stable-before-electroporation
    From the paper

    Repeated sets of PEFs at 150 and 230 V/cm, delivered in alternation, produced ΔF responses that stayed constant both within each set and between the sets (Fig. 2C and D).

    Result

    Needs the Di-8-ANEPPS alternation of 150 and 230 V/cm sets of Fig. 2C and D (n = 8); the dandiset holds no alternation protocol and no 230 V/cm set.

  • Blocked

    At 1000 V/cm the cathodic pole dF fell from 40 +- 10% at the start of the set to 26.6 +- 8% at its end, a trend that was not statistically significant.

    Needs the 1000 V/cm Di-8-ANEPPS set of the Fig. 2C cells (n = 8); not in the dandiset.

    Data missing from the datasetFigure 2C; Results 3.2, paragraph 4fig2c-1000-within-set
    From the paper

    In contrast, at an electroporating field strength of 1000 V/cm, ΔF at the cathodic pole decreased from 40 ± 10% at the beginning of the set to 26.6 ± 8% at the end of it. Although not statistically significant (p > 0.05)

    Reported statistics
    • 2-tailed paired t-test (named in the Fig. 2 legend), p > 0.05 (n = 8 cells)
    Result

    Needs the 1000 V/cm Di-8-ANEPPS set of the Fig. 2C cells (n = 8); not in the dandiset.

  • Blocked

    Set-averaged dF stayed nearly constant before the 1000 V/cm exposure but was about 20% lower in the sets after it.

    Needs the Fig. 2C and D sets before and after 1000 V/cm (n = 8); not in the dandiset.

    Data missing from the datasetFigure 2D and legend; Results 3.2, paragraph 4question to the readerfig2d-lasting-reduction
    From the paper

    ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05).

    Reported statistics
    • 2-tailed paired t-test, p < 0.05 (n = 8 cells)
    Result

    Needs the Fig. 2C and D sets before and after 1000 V/cm (n = 8); not in the dandiset.

  • Blocked

    Fitted linearly through the origin over -150 to +150 mV IMPC, FluoVolt changes by 26% and Di-8-ANEPPS by 9.1% dF per 100 mV, with correlation coefficients 0.96 and 0.78.

    Needs the 43 to 360 V/cm sets of both dyes and the cells' radii in um.

    Data missing from the datasetFigure 3 and legend; Results 3.3, paragraph 1uses data from outside the datasetfig3-dye-sensitivity
    From the paper

    The correlation coefficients of the fits equaled 0.96 for FluoVolt and 0.78 for Di-8 ANEPPS (due to a lower signal-to-noise ratio), with respective slope coefficients of 26% and 9.1% ΔF per 100 mV of IMP.

    Result

    Needs the 43 to 360 V/cm sets of both dyes and the cells' radii in um. The dandiset holds no Di-8-ANEPPS set and no FluoVolt set at 43, 230 or 360 V/cm, and its files give no pixel size, so no radius in um. The outside input (the tau fit of reference [20]) was not pinned, as the recordings it would be applied to are missing.

  • Blocked

    FluoVolt departed from linearity from about +-200 mV IMPC, while Di-8-ANEPPS stayed nearly linear from -500 to +500 mV; so FluoVolt's early departure reflects its dynamic range, not electroporation.

    Depends on fig3-dye-sensitivity, blocked for missing data.

    Data missing from the datasetFigure 3 and legend; Results 3.3, paragraph 1uses data from outside the datasetfig3-fluovolt-nonlinear
    From the paper

    The actual measurements with FluoVolt gradually became non-linear already at ±200 mV, while those for Di-8-ANEPPS stayed essentially linear throughout the tested range from −500 to +500 mV.

    Result

    Depends on fig3-dye-sensitivity, blocked for missing data.

  • Blocked

    FluoVolt measured and calculated IMP matched only at 43 and 150 V/cm; with stronger 1-us pulses the pole dF peaked at 71 +- 10% (cathodic) and -83.5 +- 5% (anodic), about +260 and -330 mV.

    Needs the Fig. 4A FluoVolt escalation (n = 4, 43 to 1400 V/cm) and the per-cell IMPC; neither the recordings…

    Data missing from the datasetFigure 4A; Results 3.4, paragraph 1uses data from outside the datasetfig4a-fluovolt-limits
    From the paper

    However, this assumption held only for the applied fields of 43 and 150 V/cm, where measured and calculated IMP matched. With stronger PEFs, maximum ΔF reached 71 ± 10% and −83.5 ± 5% at the cathodic and anodic poles, respectively.

    Result

    Needs the Fig. 4A FluoVolt escalation (n = 4, 43 to 1400 V/cm) and the per-cell IMPC; neither the recordings nor a pixel size for the radius are in the dandiset (see fig2a-fluovolt-saturation for the dandiset's own FluoVolt single-pulse sets, measured as a variant).

  • Blocked

    FluoVolt cathodic polarization fell from 71% at 360 V/cm to 45 to 50% at 1000 to 1400 V/cm.

    Needs the Fig. 4A cells at 360 and 1000 to 1400 V/cm; the dandiset has no 360, 1000, 1200 or 1400 V/cm set.

    Data missing from the datasetFigure 4A; Results 3.4, paragraph 1fig4a-fluovolt-cathodic-decline
    From the paper

    Notably, polarization at the cathodic pole decreased from 71% at 360 V/cm to 45–50% at 1000–1400 V/cm, indicating that the more severe membrane damage prevented its polarization to the maximum.

    Result

    Needs the Fig. 4A cells at 360 and 1000 to 1400 V/cm; the dandiset has no 360, 1000, 1200 or 1400 V/cm set. In the dandiset's own single-pulse sets (variant, no outcome, 4 cells) the cathodic response with the offset removed is 14.3% at 150 V/cm, 7.0% at 900, 9.0% at 1270 and 15.6% at 1570 V/cm.

  • Blocked

    With Di-8-ANEPPS and 1-us pulses, measured IMP fell below the calculated value at 570 V/cm, where dF peaked at 57 +- 14% (cathodic) and -55 +- 4% (anodic), over 600 mV.

    Needs the Di-8-ANEPPS 1-us escalation of Fig. 4B (n = 5); not in the dandiset.

    Data missing from the datasetFigure 4B; Results 3.4, paragraph 2uses data from outside the datasetfig4b-di8-limits
    From the paper

    The measured IMP decreased below the calculated value when the electric field reached 570 V/cm, concurrently with reaching the maximum ΔF of 57 ± 14% at the cathodic pole and − 55 ± 4% at the anodic pole. These values corresponded to membrane polarization by over 600 mV, which is twice the value measured with FluoVolt.

    Result

    Needs the Di-8-ANEPPS 1-us escalation of Fig. 4B (n = 5); not in the dandiset.

  • Blocked

    Averaged over only the first 10 of the 60 pulses, Di-8-ANEPPS cathodic polarization reached 66 +- 15% (710 +- 200 mV), so the 600-mV maximum is not the dye's limit.

    Needs the Fig. 4B cells; not in the dandiset.

    Data missing from the datasetFigure 4B, dotted lines; Results 3.4, paragraph 3fig4b-first-10-pulses
    From the paper

    Polarization measured this way reached 66 ± 15% (710 ± 200 mV) at the cathodic pole, suggesting that the 600-mV maximum, averaged from 60 PEFs, was not the dye limit but the actual IMP

    Result

    Needs the Fig. 4B cells; not in the dandiset. Depends on fig4b-di8-limits.

  • Blocked

    Above 780 V/cm the pole IMP fell progressively with field strength, more at the cathodic pole; at 1400 V/cm the cathodic pole no longer charged and the anodic pole fell to about -30% dF (-330 mV).

    Needs the Fig. 4B cells at 780 to 1400 V/cm; not in the dandiset.

    Data missing from the datasetFigure 4B; Results 3.4, paragraph 4fig4b-cathodic-asymmetry
    From the paper

    As the electric field increased further, the IMP reached at the poles progressively decreased, and the reduction was more pronounced at the cathodic pole ... At 1400 V/cm, charging was no longer detectable at the cathodic pole (i.e., the membrane became fully permeable) and dropped to ~30% ΔF (~ −330 mV) at the anodic pole.

    Result

    Needs the Fig. 4B cells at 780 to 1400 V/cm; not in the dandiset.

  • Blocked

    Membrane regions nearer the equator were unaffected by pole electroporation and followed the cosine dependence of the Schwan equation up to 1000 V/cm.

    Needs the Fig. 4B cells and their IMPC; not in the dandiset.

    Data missing from the datasetFigure 4C and legend; Results 3.4, paragraph 4uses data from outside the datasetfig4c-equator-follows-cosine
    From the paper

    Membrane areas closer to the equator ... appeared relatively unaffected and followed the cosine dependence predicted by Schwan formula up to 1000 V/cm (Fig. 4C).

    Result

    Needs the Fig. 4B cells and their IMPC; not in the dandiset.

  • Blocked

    With 0.3-us pulses at higher fields (357 to 3320 V/cm), imaged at 275 ns, the maximum dF was 53 +- 4% (about 600 mV) at both poles, as with 1-us pulses, and the response changed with field strength in the same way.

    Needs the 0.3-us Di-8-ANEPPS escalation (n = 10); every set in the dandiset uses 1-us pulses.

    Data missing from the datasetFigure 4D; Results 3.4, paragraph 5fig4d-short-pulses-same-limit
    From the paper

    Contrary to the expectations, the results were similar to those with 1-μs pulses in Fig. 4B: the maximum ΔF reached was 53 ± 4% (~600 mV) at both cell poles. The pattern of how the response changed with increasing PEF strength was not different from that with 1-μs PEFs either.

    Result

    Needs the 0.3-us Di-8-ANEPPS escalation (n = 10); every set in the dandiset uses 1-us pulses.

  • Blocked

    With 1 mM Gd3+ the anodic pole charged to -864 +- 44 mV, against -542 +- 57 mV in parallel controls (p < 0.001).

    Needs the Gd3+ (n = 7) and control (n = 5) Di-8-ANEPPS cells; the dandiset holds no Gd3+ experiment and no…

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 1fig5a-gd-extends-anodic
    From the paper

    Indeed, we found that 1 mM Gd3+ extended the range of membrane charging at the anodic pole down to −864 ± 44 mV (p < 0.001 compared to −542 ± 57 mV in parallel control experiments, Fig. 5A).

    Reported statistics
    • 2-tailed t-test (Fig. 5 legend), p < 0.001 (n = 7 cells with Gd3+, 5 control cells)
    Result

    Needs the Gd3+ (n = 7) and control (n = 5) Di-8-ANEPPS cells; the dandiset holds no Gd3+ experiment and no Di-8-ANEPPS recording.

  • Blocked

    With Gd3+, the measured IMP stayed nearly identical to IMPC down to -780 mV, so the Di-8-ANEPPS calibration holds at high IMPs.

    Needs the Gd3+ cells of Fig. 5A; not in the dandiset.

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 1uses data from outside the datasetfig5a-gd-linear
    From the paper

    Furthermore, measured IMP remained nearly identical to the theoretical IMPC down to −780 mV, indicating that the dye response remained linear and its calibration was valid even at high IMPs.

    Result

    Needs the Gd3+ cells of Fig. 5A; not in the dandiset.

  • Blocked

    At the cathodic pole Gd3+ cells reached 647 +- 44 mV, not significantly above controls, but Gd3+ prevented the decline of IMP with stronger fields.

    Needs the Gd3+ and control cells of Fig. 5A; not in the dandiset.

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 2fig5a-gd-cathodic
    From the paper

    At the cathodic pole, polarization in the presence of Gd3+ reached 647 ± 44 mV, a value not significantly higher than that in the control group without Gd3+. However, Gd3+ prevented the progressive decline in IMP as the electric field was increased.

    Result

    Needs the Gd3+ and control cells of Fig. 5A; not in the dandiset.

  • Blocked

    Gd3+ and control data differ significantly for datapoints with IMPC below -700 mV and above 1200 mV.

    Needs the Gd3+ and control cells of Fig. 5A; not in the dandiset.

    Data missing from the datasetFigure 5A legenduses data from outside the datasetfig5a-gd-differences
    From the paper

    Differences between Gd3+ and control group data are significant at p < 0.05 or better (2-tailed t-test) for datapoints below −700 mV and above 1200 mV.

    Reported statistics
    • 2-tailed t-test, p < 0.05 (n = 7 cells with Gd3+, 5 control cells)
    Result

    Needs the Gd3+ and control cells of Fig. 5A; not in the dandiset.

  • Blocked

    For most datapoints, Gd3+ reduced the electroporation-induced effective membrane conductivity 2 to 3-fold.

    Needs the Gd3+ and control datapoints of Fig. 5A, which are not in the dandiset.

    Data missing from the datasetFigure 5C; Results 3.5, paragraph 4uses data from outside the datasetfig5c-gd-reduces-conductivity
    From the paper

    For most datapoints, Gd3+ reduced the electroporation- induced effective conductivity 2–3-fold.

    Result

    Needs the Gd3+ and control datapoints of Fig. 5A, which are not in the dandiset. The calibration it depends on (fig5b-conductivity-calibration) was computed.

  • Blocked

    A single 1-us pulse caused clear Ca2+ entry at 1000 and 1200 V/cm, with the signal elevated through 5 min; the small rise at 780 V/cm was not significant.

    Needs Fluo-4 calcium time series (14 cells, 5-min recordings); the dandiset holds only potentiometric strobe…

    Data missing from the datasetFigure 6A; Results 3.6, paragraph 2fig6a-ca-single-pulse
    From the paper

    Exposure to a single 1-μs pulse at escalating field strengths, from 0 to 1200 V/cm established a clear peak of Ca2+ entry at 1000 and 1200 V/ cm, and Ca2+ signal remained elevated through the 5-min observation period (Fig. 6A). A subtle ΔF increase after exposure at 780 V/cm was at the detection limit and not statistically significant.

    Result

    Needs Fluo-4 calcium time series (14 cells, 5-min recordings); the dandiset holds only potentiometric strobe images of 60 frames.

  • Blocked

    After a train of sixty 1-us pulses at 6 Hz, 28% of cells responded strongly at 780 V/cm and nearly all at higher field strengths.

    Needs the Fluo-4 recordings of 224 cells after 60-pulse trains; not in the dandiset.

    Data missing from the datasetFigure 6B; Results 3.6, paragraph 3fig6b-ca-train-responders
    From the paper

    A strong Ca2+ response was recorded in 28% of cells exposed at 780 V/cm and in nearly all cells at higher intensities (Fig. 6B).

    Result

    Needs the Fluo-4 recordings of 224 cells after 60-pulse trains; not in the dandiset.

  • Blocked

    At 650 V/cm only 2 cells (5.9%) responded strongly, yet the mean Ca2+ signal at the end of recording differed from zero (p < 0.001) and was marginally higher than at 230 V/cm (p < 0.05).

    Needs the Fluo-4 recordings at 230 and 650 V/cm; not in the dandiset.

    Data missing from the datasetFigure 6B; Results 3.6, paragraph 3fig6b-ca-650
    From the paper

    At 650 V/cm, only 2 cells (5.9%) showed a strong response, but the mean Ca2+ signal by the end of recording was significantly different from zero (p < 0.001, one sample t-test) and marginally higher than after exposure at 230 V/cm (p < 0.05, single-tailed t-test).

    Reported statistics
    • 650 V/cm mean signal at the end of recording against zero: one sample t-test, p < 0.001 (n = about 34 cells (2 cells are 5.9%))
    • 650 against 230 V/cm: single-tailed t-test, p < 0.05
    Result

    Needs the Fluo-4 recordings at 230 and 650 V/cm; not in the dandiset.

  • Blocked

    The azimuthal profile of a 150 V/cm test pulse given 5 us after a conditioning pulse kept the cosine shape of an undamaged membrane after conditioning pulses up to 1000 V/cm, while after 1200 and 1400 V/cm charging at the poles was markedly reduced.

    The criterion uses the Di-8-ANEPPS two-pulse cells of Fig. 7A (n = 5) with conditioning at 150 to 1400 V/cm.

    Data missing from the datasetFigure 7A and legend; Results 3.7, paragraph 3question to the readerfig7a-cosine-profiles
    From the paper

    Polarization still followed a cosine function after conditioning PEFs of up to 1000 V/cm. However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles, indicating a persistent membrane permeabilization.

    Result

    The criterion uses the Di-8-ANEPPS two-pulse cells of Fig. 7A (n = 5) with conditioning at 150 to 1400 V/cm. The dandiset's 5-us pairs are two fields of view (c2, c9; 5 cells) stained with FluoVolt (all 72 files name FluoVolt and a FITC filter cube), recorded with 1.00-mm electrodes where the paper states 1.6 mm, with conditioning at 150, 520, 900, 1270 and 1570 V/cm and 20 and 40 frames per set. They are a different experiment, so the claim is not tested on them. Their profiles are shown in the notebook as a variant.

  • Blocked

    Normalized to 150 V/cm, pole polarization during the conditioning pulse fell 1.5 times below linear scaling at 560 V/cm and 2-fold at 760 V/cm, and further at stronger fields (p < 0.01 for every point from 560 V/cm).

    Its data are those of Fig. 4B (Di-8-ANEPPS escalation, n = 5), as the criterion states; not in the dandiset.

    Data missing from the datasetFigure 7B, top panels; Results 3.7, paragraph 5fig7b-charging-during-pulse
    From the paper

    Actual measurements fell 1.5 times below this line for 560 V/cm PEFs, 2- fold for 760 V/cm PEFs, and diverged further for more intense PEFs (p < 0.01 for all datapoints ≥560 V/cm, one sample t-test).

    Reported statistics
    • one sample t-test, p < 0.01 (n = 5 cells)
    Result

    Its data are those of Fig. 4B (Di-8-ANEPPS escalation, n = 5), as the criterion states; not in the dandiset. The dandiset's FluoVolt single-pulse sets (c6, c7) are not those data.

  • Blocked

    A 150 V/cm test pulse 5 us after the conditioning pulse charged the poles as in undamaged cells after conditioning up to 760 V/cm, to about 80% (not significant) after 1000 V/cm, and to about 70% and 50% after 1200 and 1400 V/cm, a persistent permeabilization.

    The Fig. 7 Di-8-ANEPPS two-pulse cells (n = 5) are not in the dandiset (see fig7a-cosine-profiles).

    Data missing from the datasetFigure 7A and 7B, bottom panels; Results 3.7, paragraphs 3 and 5fig7ab-test-pulse-recovery
    From the paper

    However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles, indicating a persistent membrane permeabilization ... In contrast, measurements 6 μs later (test pulse) did not differ from the control up to 760 V/cm strength of the conditioning PEF; they were at ~80% of the control reading after 1000 V/cm conditioning PEF but the difference was not statistically significant. Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test).

    Reported statistics
    • 1200 V/cm conditioning, test pulse against control: two-sided t-test, p < 0.05 (n = 5 cells)
    • 1400 V/cm conditioning, test pulse against control: two-sided t-test, p < 0.01 (n = 5 cells)
    Result

    The Fig. 7 Di-8-ANEPPS two-pulse cells (n = 5) are not in the dandiset (see fig7a-cosine-profiles). As a variant only, the dandiset's FluoVolt 5-us pairs measured with the paper's pole measure give a test-pulse response of 70% and 64% of the 150/150 set at the anodic pole after 1270 and 1570 V/cm (mean over 5 cells), while the cathodic values vary between cells from -941 to 1074%, as the uniform dimming of the pulse frames (-10.1% at the control) is larger than the cathodic response (4.5%). With that offset removed, the cathodic response is 90 to 92% after 520 and 900 V/cm, 76% after 1270 and 68% after 1570 V/cm.

  • Blocked

    Within 6 us of the electroporating pulse, effective membrane conductivity at the poles fell by a factor of about 10 (range 7 to 20) for most datapoints; the cathodic pole, more conductive during the pulse, no longer differed from the anodic pole at the test pulse.

    Depends on fig7b-charging-during-pulse and fig7ab-test-pulse-recovery, both blocked for missing data.

    Data missing from the datasetFigure 7C; Results 3.7, paragraph 7fig7c-fast-conductivity-drop
    From the paper

    Fig. 7C shows a profound reduction in the λm,eff within just 6 μs after the electroporating pulse. For most datapoints, it dropped by a factor of 10 (range: 7–20). While the cathodic pole became more conductive than the anodic pole during the electroporating pulse ... no difference between the poles was detected by the test pulse.

    Result

    Depends on fig7b-charging-during-pulse and fig7ab-test-pulse-recovery, both blocked for missing data.

  • Blocked

    After mildly electroporating 570 and 760 V/cm pulses the membrane resealed fully within 6 us; after stronger pulses a residual conductivity increase persisted.

    Depends on fig7ab-test-pulse-recovery, blocked for missing data.

    Data missing from the datasetFigure 7C; Results 3.7, paragraph 7fig7c-full-reseal-mild
    From the paper

    For mildly electroporating PEFs of 570 and 760 V/cm, membrane resealed fully (within the accuracy of measurements) within just 6 μs. With more intense PEFs, the residual increased conductivity persisted for at least 6 μs, indicating the formation of more stable membrane lesions.

    Result

    Depends on fig7ab-test-pulse-recovery, blocked for missing data.

Attempt semenov-2026-03, on DANDI:001517 version 0.261006.1856

Reproducing Semenov et al. (2026) from dandiset 001517 16 Open in Colab

Reproduced5

  • Reproduced

    With Di-8-ANEPPS and 1-us pulses, polarization grows with field strength up to 570 V/cm; at 780 V/cm the cathodic pole stops increasing and dims, and at 1000 to 1400 V/cm the poles show reduced or absent polarization while regions nearer the equator stay polarized and may polarize more than the poles.

    Under every background reading the cathodic pole is lower at 780 than at 570 V/cm (far 38.6 against 41.7%…

    Figure 1 and its legend; Results 3.1, paragraph 1rests on an assumptionfig1-pole-dimming
    From the paper

    At a higher electric field strength of 780 V/cm, polarization at the cathodic pole does not further increase but dims out, indicating a less efficient charging of the partially permeabilized membrane. Still stronger electric fields produce a distinct pattern of reduced or absent polarization at the poles ... while regions closer to the equator remain relatively intact and may polarize more than the poles

    Result

    Under every background reading the cathodic pole is lower at 780 than at 570 V/cm (far 38.6 against 41.7%; near 65.0 against 67.9; none 15.2 against 16.0), and at 1400 V/cm the largest mean dF of the cathode-facing hemisphere lies 65 degrees from the pole (far 21.7% at -65 degrees against 7.5% at the pole; near and none also at -65). Both conditions hold at every band of the background sweep and with the local backgrounds. In each of the 8 cells the 1400 V/cm maximum lies 43 to 76 degrees from the pole. Five-cell subsets passing 56 of 56 (far), 45 (near), 51 (none). The Fig. 1 cell is not identified; the test uses the Fig. 4B cells as the criterion says.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.
  • Reproduced

    Di-8-ANEPPS dF kept increasing with field strength up to 570 V/cm at both poles.

    Mean |dF| over the 60 pulse images rises at every step from 43 to 570 V/cm at both poles under every…

    Figure 2B; Results 3.2, paragraph 3rests on an assumptionfig2b-di8-climbs-to-570
    From the paper

    This dye has a lower sensitivity to membrane polarization (note the vertical scale different from Fig. 2A), but ΔF kept climbing up to the electric field strength of 570 V/cm at both cell poles.

    Result

    Mean |dF| over the 60 pulse images rises at every step from 43 to 570 V/cm at both poles under every background reading, every band of the sweep and the local backgrounds (far cathodic 1.1, 15.9, 23.3, 33.3, 41.5%; anodic 9.1, 17.2, 25.8, 32.6, 39.4%), and in all 56 five-cell subsets under each of far, near and none.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.
  • Reproduced

    Di-8-ANEPPS responses were somewhat affected by bleaching, most visibly at 43 V/cm, where bleaching added about 5% to dF at the anodic pole and took about 5% from it at the cathodic pole.

    Reading (b), the offset common to both poles in the 43 V/cm set, is -5.11% (far) and -5.00% (near), within -5…

    Figure 2B; Results 3.2, paragraph 3rests on an assumptionfig2b-di8-bleaching
    From the paper

    The responses were somewhat affected by dye bleaching (particularly noticeable at 43 V/cm, where bleaching added ~5% to ΔF at the anodic pole and reduced it by the same ~5% at the cathodic pole.

    Result

    Reading (b), the offset common to both poles in the 43 V/cm set, is -5.11% (far) and -5.00% (near), within -5 +- 0.5; without background -2.63%. Every band of the sweep gives -4.58 to -5.12% (within), the far local background -5.32% (within), the near local -6.30% (outside). Reading (a), last 10 minus first 10 pulse images, misses at the anodic pole under every background (far cathodic -5.32, anodic -3.39%). The result is fragile: 38 of 56 five-cell subsets pass under the far background (13 near, 0 none), and with dark frames kept reading (b) gives -2.18% (far). Over the last 10 pulse images both poles sit 7.2% below baseline (far), a downward drift through the set at both poles, as the text describes.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.
  • Reproduced

    With Di-8-ANEPPS, responses to pulses of 780 V/cm and above decreased gradually within each set of 60 images.

    Far background, cathodic |dF| from start to end of each set, reading (a) 40.1 to 35.8, 40.8 to 22.4, 32.2 to…

    Figure 2B; Results 3.2, paragraph 3rests on an assumptionfig2b-di8-decline-within-set
    From the paper

    In addition, responses to PEFs at and above 780 V/cm decreased gradually in each set of 60 images, consistent with expectations of adding membrane damage by additional electroporation pulses in each set

    Result

    Far background, cathodic |dF| from start to end of each set, reading (a) 40.1 to 35.8, 40.8 to 22.4, 32.2 to 17.4, 16.4 to 8.7% at 780 to 1400 V/cm; reading (b) 41.1 to 34.3, 37.0 to 25.2, 25.5 to 15.3, 15.6 to 8.7% (paired p 0.017, 0.001, 0.002, 0.092). Both readings decline in every set under every band of the sweep, without background and with the near background; with the near local background reading (a) fails. Five-cell subsets passing 44 (a) and 52 (b) of 56. The anodic variant does not decline at 780 V/cm. Bleaching control (after verification round 1): below electroporation the cathodic dF also falls through each set (reading b, -3.5 to -4.6% at 230 to 570 V/cm, common-mode change of both poles -1.7 to -3.4%), so the fall at 780 V/cm (-6.8%, -3.3% net of the common mode against -2.6% at 570) is about the size of the bleaching drift; the falls at 1000 to 1400 V/cm (-9.5 to -11.8%, net -6.0 to -7.5%) exceed it. The criterion holds as written; the part at 780 V/cm cannot be told from bleaching.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.
  • Reproduced

    Normalized to 150 V/cm, pole polarization during the conditioning pulse fell 1.5 times below linear scaling at 560 V/cm and 2-fold at 760 V/cm, and further at stronger fields (p < 0.01 for every point from 560 V/cm).

    Far background, first reading (normalised per cell, cathodic pole), line over measured 1.465 at 570 and 2.153…

    Figure 7B, top panels; Results 3.7, paragraph 5rests on an assumptionfig7b-charging-during-pulse
    From the paper

    Actual measurements fell 1.5 times below this line for 560 V/cm PEFs, 2- fold for 760 V/cm PEFs, and diverged further for more intense PEFs (p < 0.01 for all datapoints ≥560 V/cm, one sample t-test).

    Reported statistics
    • one sample t-test, p < 0.01 (n = 5 cells)
    Result

    Far background, first reading (normalised per cell, cathodic pole), line over measured 1.465 at 570 and 2.153 at 780 V/cm, 3.4, 6.0 and 13.3 at 1000 to 1400 V/cm, every point from 570 V/cm below the line (largest one-sample p 0.001). All six readings pass under the far background (1.45 to 1.64 and 2.09 to 2.15), four of six near and five of six without background, and some reading passes at every band of the sweep and with the far local background; 43 (far), 46 (near) and 46 (none) of 56 five-cell subsets pass. The outcome rests on the in-order matching of volts to V/cm: with the field proportional to the volts the line at the 150 V set is 300% in place of 380%, the ratios are 1.15 to 1.29 at 570 and 1.61 to 1.66 at 780 V/cm, and no reading passes under any background. The first step of the data (25 to 50 V triples the response, against 2.0 for proportional volts) supports the in-order matching.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.

Partially reproduced3

  • Partially reproduced

    Fitted linearly through the origin over -150 to +150 mV IMPC, FluoVolt changes by 26% and Di-8-ANEPPS by 9.1% dF per 100 mV, with correlation coefficients 0.96 and 0.78.

    Changed from not_reproduced after verification round 1: two of the four values (the correlations) are within…

    Figure 3 and legend; Results 3.3, paragraph 1verifier disagreed at firstrests on an assumptionuses data from outside the datasetfig3-dye-sensitivity
    From the paper

    The correlation coefficients of the fits equaled 0.96 for FluoVolt and 0.78 for Di-8 ANEPPS (due to a lower signal-to-noise ratio), with respective slope coefficients of 26% and 9.1% ΔF per 100 mV of IMP.

    Result

    Changed from not_reproduced after verification round 1: two of the four values (the correlations) are within tolerance and the slopes are present but 17 and 19% lower. Far background, perimeter radius, slopes 21.57 (FluoVolt, 3008 points) and 7.38% per 100 mV (Di-8-ANEPPS, 5776 points) against 26 +- 2.6 and 9.1 +- 0.91; Pearson r 0.964 and 0.762, uncentred 0.950 and 0.660; ratio of the slopes 2.92 against the paper's 2.86. The equal-area radius gives 21.62 and 7.48. Near 30.69 and 11.46, none 10.95 and 3.33. With the pixel that gives the paper's average radius of 8 um (0.192 um) the far background gives 26.62 and 9.53 with Pearson 0.976 and 0.831, all within tolerance, as are the bands from 26 to 44 pixels; with the adopted pixel only the 14 to 20 pixel band passes (25.24 and 8.86). The files store no pixel size (the dump of a file in the data check holds no ImagingPlane, Device or grid spacing). With the field proportional to the volts the slopes are 13.05 and 4.37 (adopted pixel) or 18.03 and 6.00 (8-um pixel). Di-8-ANEPPS slope over the 56 five-cell subsets 6.48 to 8.27. The local backgrounds break down on whole profiles (Pearson 0.012 to 0.137 with the adopted pixel, 0.005 and -0.02 with the 8-um pixel).

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • FluoVolt cells c2, c3, c4 and c6 are used, the four with exactly the nine-set escalation of Fig. 2A (n = 4); c5, whose escalation follows an extra 350 V set, is a variant.
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • The pixel size is taken as 0.267 um (16-um pixels of the iXon Ultra 897 behind the 60x objective, Methods 2.3); the files do not give it. Mean radii are then 7.8 to 15.1 um by cell (perimeter 7.84 to 15.06, equal-area 7.80 to 14.92; 7.84 to 12.85 over the cells used) against the paper's average of about 8 um; a variant uses the 0.192-um pixel that gives 8 um.
    • The charging time constant is 44.5 ns per um of radius, the fit of reference [20] Fig. 5C, as Methods 2.3 says.
  • Partially reproduced

    Above 780 V/cm the pole IMP fell progressively with field strength, more at the cathodic pole; at 1400 V/cm the cathodic pole no longer charged and the anodic pole fell to about -30% dF (-330 mV).

    Far background, both poles fall from 780 V/cm (cathodic 38.6, 31.4, 19.8, 7.5%; anodic 41.4, 36.9, 30.8…

    Figure 4B; Results 3.4, paragraph 4rests on an assumptionfig4b-cathodic-asymmetry
    From the paper

    As the electric field increased further, the IMP reached at the poles progressively decreased, and the reduction was more pronounced at the cathodic pole ... At 1400 V/cm, charging was no longer detectable at the cathodic pole (i.e., the membrane became fully permeable) and dropped to ~30% ΔF (~ −330 mV) at the anodic pole.

    Result

    Far background, both poles fall from 780 V/cm (cathodic 38.6, 31.4, 19.8, 7.5%; anodic 41.4, 36.9, 30.8, 21.6%), the cathodic pole loses more (81 against 48%), and its 1400 V/cm value does not differ from zero (7.5%, one-sample p = 0.29). The anodic value at 1400 V/cm is -21.6%, outside -30 +- 3 (none -10.7; every band of the sweep from 14 pixels out -21.3 to -23.8). The near background meets all four conditions (anodic -27.7%, cathodic 21.2%, p = 0.12; 15 of 56 subsets), so the fourth condition turns on the background distance. Far, 1 of 56 subsets passes. Before the c7 outline at 1200 and 1400 V/cm was re-traced, the far anodic value was -18.5%. With a variant outline on the outer membrane (after verification round 2) far gives an anodic 1400 V/cm value of -23.1%, still outside, and near again meets all four conditions (-28.2%).

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.
  • Partially reproduced

    By Eq. (2), the effective membrane conductivity barely affects charging while it stays far below cytosol and medium conductivities; a 10-fold rise reduces IMP by about 2% and a 100-fold rise by 12%.

    Eq. (2) with the Methods constants gives f = 1.498 at 3e-7 S/m.

    Figure 5B; Results 3.5, paragraph 3fig5b-conductivity-calibration
    From the paper

    its 10-fold increase would go unnoticed, yielding just a ~2% IMP reduction, and a 100-fold increase would reduce IMP by just 12%.

    Result

    Eq. (2) with the Methods constants gives f = 1.498 at 3e-7 S/m. A 100-fold rise reduces IMP by 11.87% (reading a, 1 - f/1.5) or 11.75% (b), within 12 +- 1.2; a 10-fold rise by 1.33% (a) or 1.20% (b), outside 2 +- 0.2. Under Eq. (2) a 2% reduction needs a 15.2-fold rise. The first part of the statement (little effect while the conductivity is far below the cytosol and medium) holds (99.6% of 1.5 at 1e-6 S/m).

    Deviations from the paper’s method
    • None; the computation uses the equation and constants of Methods 2.3 and no recordings.

Not reproduced8

  • Not reproduced

    With FluoVolt, pole dF rose with field strength until it saturated at 66% (255 mV) at 360 V/cm at the cathodic pole and -83% (-320 mV) at 570 V/cm at the anodic pole; stronger fields did not increase the anodic response and decreased the cathodic one.

    Changed from partially_reproduced after verification round 1: the criterion requires both values, and both…

    Figure 2A; Results 3.2, paragraph 2verifier disagreed at firstrests on an assumptionfig2a-fluovolt-saturation
    From the paper

    ΔF increased proportionally to the electric field strength until reaching apparent saturation at 66% ΔF (255 mV IMP) at 360 V/cm at the cathodic pole, and −83% ΔF (−320 mV IMP) at 570 V/cm at the anodic pole. Further escalation of the electric field strength did not increase the dye response at the anodic pole and even decreased it at the cathodic pole.

    Result

    Changed from partially_reproduced after verification round 1: the criterion requires both values, and both miss under the adopted far background. Per-image pole dF over the 60 pulse images, mean of 4 cells, far background: cathodic at 360 V/cm 49.4% against 66 +- 6.6, anodic at 570 V/cm -69.8% against -83 +- 8.3. The shape conditions hold (cathodic 48.1 and 37.4% at 570 and 780 V/cm; anodic -72.2 to -61.9% from 780 to 1400 V/cm; cathodic 36.6, 38.2 and 40.9% at 1000 to 1400 V/cm). Near 78.5 and -88.6% (anodic within, but 1400 V/cm rises to 80.4%, failing the 1000 to 1400 V/cm condition); none 23.7 and -37.6%. In the background sweep the band 14 to 20 pixels (4 to 5 um) out meets every condition (61.3 and -78.1%), where the membrane glow is still about a sixth of its excess; no band from 20 pixels out does. With c5 added, 55.2 and -71.2% (far); with dark frames kept, 45.6 and -69.8%.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • FluoVolt cells c2, c3, c4 and c6 are used, the four with exactly the nine-set escalation of Fig. 2A (n = 4); c5, whose escalation follows an extra 350 V set, is a variant.
  • Not reproduced

    FluoVolt measurements were stable without pulses (no significant bleaching or photosensitization), and the response within each set stayed stable through the 60 pulses, even at 1000 V/cm and above.

    Claim of absence, 2-tailed paired t-test over 4 cells, 24 tests per reading (6 pulse comparisons at 1000 to…

    Figure 2A; Results 3.2, paragraph 2rests on an assumptionquestion to the readerfig2a-fluovolt-stable
    From the paper

    Without PEF (first 40 datapoints, or ~ 7 s in each set), measurements were stable, indicating no significant photosensitization or dye bleaching ... but the dye response in each set stayed stable through the 60 pulses applied

    Result

    Claim of absence, 2-tailed paired t-test over 4 cells, 24 tests per reading (6 pulse comparisons at 1000 to 1400 V/cm and 18 baselines). Far background, reading (a) first and last image, 1 pulse set (1400 V/cm anodic, -3.2% dF, p = 0.043) and 1 baseline (1000 V/cm anodic, -7.0%, p = 0.005) change; reading (b) first and last 10 images, 2 pulse sets (1200 V/cm cathodic +5.5%, p = 0.049; 1400 V/cm anodic +2.5%, p = 0.037) and 3 baselines (150 V/cm cathodic -3.9%, 360 V/cm anodic +3.7% and cathodic -4.2%, p 0.000 to 0.008). Both readings find changes, so not reproduced. Without background both readings also find changes; with the near background reading (a) finds none and (b) three, so under that background the claim would be blocked as methods_underspecified. In the sweep reading (b) finds 3 to 6 changes at every distance. With 24 tests about 1.2 are expected below p = 0.05 by chance, and at least one in about 70% of stable recordings; the changes are a few percent dF (largest 7.0%) against responses of 40 to 70%. Whether the criterion should correct for the number of tests is asked of a reader in questions/001517.yaml.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • FluoVolt cells c2, c3, c4 and c6 are used, the four with exactly the nine-set escalation of Fig. 2A (n = 4); c5, whose escalation follows an extra 350 V set, is a variant.
    • The first lit image stands for the first image where frame 0 has no flash.
  • Not reproduced

    FluoVolt departed from linearity from about +-200 mV IMPC, while Di-8-ANEPPS stayed nearly linear from -500 to +500 mV; so FluoVolt's early departure reflects its dynamic range, not electroporation.

    Di-8-ANEPPS departs from the shared line on the cathodic side under every smooth and background (far, 2709 of…

    Figure 3 and legend; Results 3.3, paragraph 1rests on an assumptionuses data from outside the datasetfig3-fluovolt-nonlinear
    From the paper

    The actual measurements with FluoVolt gradually became non-linear already at ±200 mV, while those for Di-8-ANEPPS stayed essentially linear throughout the tested range from −500 to +500 mV.

    Result

    Di-8-ANEPPS departs from the shared line on the cathodic side under every smooth and background (far, 2709 of 5418 LOESS points from 150 to 500 mV, 5 of 14 bins; smooth over line down to 0.73). Fit side by side (far), the anodic slope is 11.63 and the cathodic 3.13% per 100 mV, so much of the departure is an asymmetry between the poles; the anodic smooth also bends (LOESS 0.5 at 0.58 to 0.80 of its own line over 150 to 500 mV). Without the 43 V/cm sets, whose cathodic values are negative (fig2b-di8-bleaching), the slopes are 10.15 (anodic) and 4.59 (cathodic), so those points account for only part of the asymmetry (output added after verification round 2). FluoVolt departs at every |IMPC| from 220 mV under LOESS 0.5 and 0.75 but not under LOESS 0.3 or 50-mV bins (far); under the near background it does under all four. With the 8-um pixel (after verification round 1) FluoVolt passes under every smooth and background but Di-8-ANEPPS still departs under every smooth (smooth over line down to 0.59 to 0.85); with the field proportional to the volts both parts fail.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • FluoVolt cells c2, c3, c4 and c6 are used, the four with exactly the nine-set escalation of Fig. 2A (n = 4); c5, whose escalation follows an extra 350 V set, is a variant.
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • The pixel size is taken as 0.267 um (16-um pixels of the iXon Ultra 897 behind the 60x objective, Methods 2.3); the files do not give it. Mean radii are then 7.8 to 15.1 um by cell (perimeter 7.84 to 15.06, equal-area 7.80 to 14.92; 7.84 to 12.85 over the cells used) against the paper's average of about 8 um; a variant uses the 0.192-um pixel that gives 8 um.
    • The charging time constant is 44.5 ns per um of radius, the fit of reference [20] Fig. 5C, as Methods 2.3 says.
  • Not reproduced

    FluoVolt measured and calculated IMP matched only at 43 and 150 V/cm; with stronger 1-us pulses the pole dF peaked at 71 +- 10% (cathodic) and -83.5 +- 5% (anodic), about +260 and -330 mV.

    Far background, maxima 49.3% (cathodic, 360 V/cm) and -72.1% (anodic, 780 V/cm), outside 71 +- 10 and -83.5 +…

    Figure 4A; Results 3.4, paragraph 1rests on an assumptionuses data from outside the datasetfig4a-fluovolt-limits
    From the paper

    However, this assumption held only for the applied fields of 43 and 150 V/cm, where measured and calculated IMP matched. With stronger PEFs, maximum ΔF reached 71 ± 10% and −83.5 ± 5% at the cathodic and anodic poles, respectively.

    Result

    Far background, maxima 49.3% (cathodic, 360 V/cm) and -72.1% (anodic, 780 V/cm), outside 71 +- 10 and -83.5 +- 5; near 80.6% (within, at 1400 V/cm) and -89.1%; none 23.6 and -41.1%. In the sweep only the 14 to 20 pixel band puts both maxima within tolerance (61.2 and -79.5%), and there measured IMP is already below IMPC at the anodic pole at 150 V/cm (-191 against -205 mV, paired p = 0.019; cathodic 188 against 205 mV, p = 0.35). Far background, measured IMP (dF / 26%) is below IMPC at every strength from 230 V/cm (paired p 0.0005 to 0.0041), but already at 150 V/cm (cathodic 155 against 205 mV, paired p = 0.037; anodic -168 against -205, p = 0.0045), so measured and calculated match at 43 V/cm only. The equal-area radius and the field proportional to the volts give the same. The 8-um pixel (162 mV calculated at 150 V/cm, paired p 0.65 and 0.25) and the near background meet the measured-against-calculated conditions under the paired test, but neither brings both maxima within tolerance.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • FluoVolt cells c2, c3, c4 and c6 are used, the four with exactly the nine-set escalation of Fig. 2A (n = 4); c5, whose escalation follows an extra 350 V set, is a variant.
    • The pixel size is taken as 0.267 um (16-um pixels of the iXon Ultra 897 behind the 60x objective, Methods 2.3); the files do not give it. Mean radii are then 7.8 to 15.1 um by cell (perimeter 7.84 to 15.06, equal-area 7.80 to 14.92; 7.84 to 12.85 over the cells used) against the paper's average of about 8 um; a variant uses the 0.192-um pixel that gives 8 um.
    • The charging time constant is 44.5 ns per um of radius, the fit of reference [20] Fig. 5C, as Methods 2.3 says.
  • Not reproduced

    FluoVolt cathodic polarization fell from 71% at 360 V/cm to 45 to 50% at 1000 to 1400 V/cm.

    Far background, collapsed cathodic dF 49.3% (s.e.

    Figure 4A; Results 3.4, paragraph 1rests on an assumptionfig4a-fluovolt-cathodic-decline
    From the paper

    Notably, polarization at the cathodic pole decreased from 71% at 360 V/cm to 45–50% at 1000–1400 V/cm, indicating that the more severe membrane damage prevented its polarization to the maximum.

    Result

    Far background, collapsed cathodic dF 49.3% (s.e. 4.3) at 360 V/cm, outside 71 +- 10, and 36.5, 38.3 and 40.9% at 1000, 1200 and 1400 V/cm, of which only the last is inside 40.5 to 55 (measured gives the mean of the three, 38.6). Near 78.3 then 66.6 to 80.6; none 23.6 then 16.7 to 18.1. The closest band of the sweep, 14 to 20 pixels, gives 61.2 then 48.2, 50.9 and 55.5%, failing only at 1400 V/cm by 0.5 point. The decline from 360 V/cm is 17 to 26% (the paper's 71 to 45-50% is 30 to 37%). Three of four cells are higher at 1400 than at 1000 V/cm.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • FluoVolt cells c2, c3, c4 and c6 are used, the four with exactly the nine-set escalation of Fig. 2A (n = 4); c5, whose escalation follows an extra 350 V set, is a variant.
  • Not reproduced

    With Di-8-ANEPPS and 1-us pulses, measured IMP fell below the calculated value at 570 V/cm, where dF peaked at 57 +- 14% (cathodic) and -55 +- 4% (anodic), over 600 mV.

    Far background, the cathodic maximum is at 570 V/cm (41.7%, below 57 +- 14 by 1.3 points), the anodic maximum…

    Figure 4B; Results 3.4, paragraph 2rests on an assumptionuses data from outside the datasetfig4b-di8-limits
    From the paper

    The measured IMP decreased below the calculated value when the electric field reached 570 V/cm, concurrently with reaching the maximum ΔF of 57 ± 14% at the cathodic pole and − 55 ± 4% at the anodic pole. These values corresponded to membrane polarization by over 600 mV, which is twice the value measured with FluoVolt.

    Result

    Far background, the cathodic maximum is at 570 V/cm (41.7%, below 57 +- 14 by 1.3 points), the anodic maximum at 780 V/cm (-41.4%, against -40.4% at 570), outside -55 +- 4. Measured IMP (dF / 9.1%) is below IMPC at 570 V/cm (cathodic 458 against 804 mV, paired p = 0.0035; anodic p < 0.0001) but also at 360 V/cm anodic (p = 0.0012) and at 43 V/cm (cathodic -11 against 60 mV, from the bleaching). The equal-area radius, the 8-um pixel and the field proportional to the volts give the same four results. No background reading, no band of the sweep and none of the 56 five-cell subsets meets every condition; with the near background both maxima are at 570 V/cm (67.9 and -61.4%, the anodic outside tolerance) but measured IMP is then not below IMPC at 570 V/cm (p 0.70 and 0.23). With a variant outline on the outer membrane (after verification round 2) the result is the same (far, cathodic maximum 44.2% at 570 V/cm, anodic -43.0% at 780 V/cm).

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.
    • The pixel size is taken as 0.267 um (16-um pixels of the iXon Ultra 897 behind the 60x objective, Methods 2.3); the files do not give it. Mean radii are then 7.8 to 15.1 um by cell (perimeter 7.84 to 15.06, equal-area 7.80 to 14.92; 7.84 to 12.85 over the cells used) against the paper's average of about 8 um; a variant uses the 0.192-um pixel that gives 8 um.
    • The charging time constant is 44.5 ns per um of radius, the fit of reference [20] Fig. 5C, as Methods 2.3 says.
  • Not reproduced

    Averaged over only the first 10 of the 60 pulses, Di-8-ANEPPS cathodic polarization reached 66 +- 15% (710 +- 200 mV), so the 600-mV maximum is not the dye's limit.

    Far background, the first-10 cathodic maximum is 43.1% (s.e.

    Figure 4B, dotted lines; Results 3.4, paragraph 3rests on an assumptionfig4b-first-10-pulses
    From the paper

    Polarization measured this way reached 66 ± 15% (710 ± 200 mV) at the cathodic pole, suggesting that the 600-mV maximum, averaged from 60 PEFs, was not the dye limit but the actual IMP

    Result

    Far background, the first-10 cathodic maximum is 43.1% (s.e. 6.8) at 570 V/cm, above the 60-image maximum (41.7%) but outside 66 +- 15; 5 of 56 five-cell subsets pass. None 16.5%. The near background (69.8% at 1000 V/cm, s.e. 16.1, above its 60-image maximum of 67.9%; 43 of 56 subsets) and the 14 to 20 pixel band (53.3% at 570 V/cm) pass; every band from 20 pixels out fails (41.0 to 47.0%). Before the c7 outline was re-traced the near value was 88.5% at 1200 V/cm. With a variant outline on the outer membrane (after verification round 2) far gives 45.5%, still outside, and near 72.7%, within.

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.
  • Not reproduced

    Membrane regions nearer the equator were unaffected by pole electroporation and followed the cosine dependence of the Schwan equation up to 1000 V/cm.

    Far background, 16 of 24 equatorial arcs (2 widths, 3 strengths, 4 arcs) differ from IMPC under both the…

    Figure 4C and legend; Results 3.4, paragraph 4rests on an assumptionuses data from outside the datasetfig4c-equator-follows-cosine
    From the paper

    Membrane areas closer to the equator ... appeared relatively unaffected and followed the cosine dependence predicted by Schwan formula up to 1000 V/cm (Fig. 4C).

    Result

    Far background, 16 of 24 equatorial arcs (2 widths, 3 strengths, 4 arcs) differ from IMPC under both the paired and the unpaired t-test; ratios of measured to calculated 0.40 to 0.98, lowest on the cathodic side of the 270-degree equator (0.40 to 0.61). None of the 56 five-cell subsets is free of differing arcs. Near background, 1 arc differs under both; no background, 24; the sweep from 14 pixels out, 6 to 16. With the 8-um pixel variant 7 (paired) and 9 (unpaired); with the field proportional to the volts 16. At 570 and 780 V/cm the 15-degree arcs beside 90 degrees and on the anodic side at 270 degrees match (ratios 0.75 to 0.98, p 0.08 to 0.93). With a variant outline on the outer membrane (after verification round 2) 16 of 24 arcs still differ under both tests (far).

    Deviations from the paper’s method
    • Field strengths are matched in order to the generator volts the files give (25 V as 43 V/cm, 50 as 150, 70 as 230, 100 as 360, 150 as 570, 200 as 780, 250 as 1000, 300 as 1200, 350 as 1400), an assumption. The paper names nine field strengths for its 1-us escalations and the files nine amplitudes, but the two are not proportional, and below electroporation the data fit a proportional response about as well on the volts as on the paper's V/cm. The first step supports the matching: from 25 to 50 V the mean pole |dF| triples (FluoVolt 3.05, Di-8-ANEPPS 2.90), against 3.49 for the paper's 43 to 150 V/cm and 2.00 for proportional volts. A variant with the field proportional to the volts (4 V/cm per V) is shown for every claim that uses the field strength as a number.
    • Background is subtracted from ROIs 30 to 36 pixels (8 to 10 um) outside the membrane, 20 degrees wide, near each pole (the far reading), an assumption. The paper does not state a background method for the laser images; its Methods follow reference [20] ('Most methods were identical to those described in detail recently [20]'), which places background ROIs 'near the poles outside of the cell' with no distance. The data check shows the membrane's glow is still a third of its excess 2 um out and a few percent 8 um out. The near (2 to 4 um) and no-background readings are shown and change dF by up to a factor of three. After verification round 1 every claim also shows a sweep of 6-pixel bands from 8 to 44 pixels out and a per-pole (local) background.
    • The perimeter trace (6 pixels wide, Methods 2.3) is found automatically as the peak of intensity on 360 rays of each set's baseline image, with polar angles from the cell centre; the paper drew it by hand in MetaMorph and resampled by perimeter length. Sets whose outline radius departs from the cell's median by more than 15% are traced again within 8 pixels of the cell's median centre and 4 pixels of its median radius; this re-traced FluoVolt c2 at 300 V (outline on a neighbouring cell) and Di-8-ANEPPS c7 at 300 and 350 V (outline on a body inside the cell), found in the outline overlays added after verification round 1.
    • Frames without a laser flash, which the files do not flag (frame 0 of 137 of 141 sets and 290 others), are left out of every average; the paper does not mention them. Keeping them is shown as a variant.
    • The field direction is not stored. The cathode-facing pole is placed where dF is positive (Methods 2.3, emission increased in the cathode-facing hemisphere), on one axis for all sets estimated from the 50 to 100 V sets (per-set median deviation 1.6 degrees).
    • All eight Di-8-ANEPPS escalation cells (c7 to c14) are used where the paper reports n = 5 without naming them; the criterion is also run on each of the 56 five-cell subsets.
    • Di-8-ANEPPS c13 has two 150 V sets; the first, in escalation order, is used.
    • The pixel size is taken as 0.267 um (16-um pixels of the iXon Ultra 897 behind the 60x objective, Methods 2.3); the files do not give it. Mean radii are then 7.8 to 15.1 um by cell (perimeter 7.84 to 15.06, equal-area 7.80 to 14.92; 7.84 to 12.85 over the cells used) against the paper's average of about 8 um; a variant uses the 0.192-um pixel that gives 8 um.
    • The charging time constant is 44.5 ns per um of radius, the fit of reference [20] Fig. 5C, as Methods 2.3 says.

Not tested in a notebook 15

15 data missing from the dataset

Blocked15

  • Blocked

    Repeated alternating sets at 150 and 230 V/cm (480 pulses and 800 flashes) gave dF responses constant within and between sets.

    The alternating 150 and 230 V/cm sets followed by 1000 V/cm (Fig.

    Data missing from the datasetFigure 2C and 2D; Results 3.2, paragraph 4fig2cd-stable-before-electroporation
    From the paper

    Repeated sets of PEFs at 150 and 230 V/cm, delivered in alternation, produced ΔF responses that stayed constant both within each set and between the sets (Fig. 2C and D).

    Result

    The alternating 150 and 230 V/cm sets followed by 1000 V/cm (Fig. 2C/D, n = 8) are not in the dandiset; every cell there follows an escalation of amplitudes. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    At 1000 V/cm the cathodic pole dF fell from 40 +- 10% at the start of the set to 26.6 +- 8% at its end, a trend that was not statistically significant.

    Needs the Fig. 2C experiment (alternating sets, then 1000 V/cm, n = 8), which is not in the dandiset.

    Data missing from the datasetFigure 2C; Results 3.2, paragraph 4fig2c-1000-within-set
    From the paper

    In contrast, at an electroporating field strength of 1000 V/cm, ΔF at the cathodic pole decreased from 40 ± 10% at the beginning of the set to 26.6 ± 8% at the end of it. Although not statistically significant (p > 0.05)

    Reported statistics
    • 2-tailed paired t-test (named in the Fig. 2 legend), p > 0.05 (n = 8 cells)
    Result

    Needs the Fig. 2C experiment (alternating sets, then 1000 V/cm, n = 8), which is not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    Set-averaged dF stayed nearly constant before the 1000 V/cm exposure but was about 20% lower in the sets after it.

    Needs the Fig. 2C/D experiment, which is not in the dandiset.

    Data missing from the datasetFigure 2D and legend; Results 3.2, paragraph 4question to the readerfig2d-lasting-reduction
    From the paper

    ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05).

    Reported statistics
    • 2-tailed paired t-test, p < 0.05 (n = 8 cells)
    Result

    Needs the Fig. 2C/D experiment, which is not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    With 0.3-us pulses at higher fields (357 to 3320 V/cm), imaged at 275 ns, the maximum dF was 53 +- 4% (about 600 mV) at both poles, as with 1-us pulses, and the response changed with field strength in the same way.

    Every file states a 1-us pulse; the 0.3-us experiments of Fig. 4D are not in the dandiset.

    Data missing from the datasetFigure 4D; Results 3.4, paragraph 5fig4d-short-pulses-same-limit
    From the paper

    Contrary to the expectations, the results were similar to those with 1-μs pulses in Fig. 4B: the maximum ΔF reached was 53 ± 4% (~600 mV) at both cell poles. The pattern of how the response changed with increasing PEF strength was not different from that with 1-μs PEFs either.

    Result

    Every file states a 1-us pulse; the 0.3-us experiments of Fig. 4D are not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    With 1 mM Gd3+ the anodic pole charged to -864 +- 44 mV, against -542 +- 57 mV in parallel controls (p < 0.001).

    No set mentions Gd3+, and there is no group of parallel controls; the Fig. 5A data are not in the dandiset.

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 1fig5a-gd-extends-anodic
    From the paper

    Indeed, we found that 1 mM Gd3+ extended the range of membrane charging at the anodic pole down to −864 ± 44 mV (p < 0.001 compared to −542 ± 57 mV in parallel control experiments, Fig. 5A).

    Reported statistics
    • 2-tailed t-test (Fig. 5 legend), p < 0.001 (n = 7 cells with Gd3+, 5 control cells)
    Result

    No set mentions Gd3+, and there is no group of parallel controls; the Fig. 5A data are not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    With Gd3+, the measured IMP stayed nearly identical to IMPC down to -780 mV, so the Di-8-ANEPPS calibration holds at high IMPs.

    The Gd3+ cells of Fig. 5A are not in the dandiset.

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 1uses data from outside the datasetfig5a-gd-linear
    From the paper

    Furthermore, measured IMP remained nearly identical to the theoretical IMPC down to −780 mV, indicating that the dye response remained linear and its calibration was valid even at high IMPs.

    Result

    The Gd3+ cells of Fig. 5A are not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    At the cathodic pole Gd3+ cells reached 647 +- 44 mV, not significantly above controls, but Gd3+ prevented the decline of IMP with stronger fields.

    The Gd3+ cells and parallel controls of Fig. 5A are not in the dandiset.

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 2fig5a-gd-cathodic
    From the paper

    At the cathodic pole, polarization in the presence of Gd3+ reached 647 ± 44 mV, a value not significantly higher than that in the control group without Gd3+. However, Gd3+ prevented the progressive decline in IMP as the electric field was increased.

    Result

    The Gd3+ cells and parallel controls of Fig. 5A are not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    Gd3+ and control data differ significantly for datapoints with IMPC below -700 mV and above 1200 mV.

    The Gd3+ cells and parallel controls of Fig. 5A are not in the dandiset.

    Data missing from the datasetFigure 5A legenduses data from outside the datasetfig5a-gd-differences
    From the paper

    Differences between Gd3+ and control group data are significant at p < 0.05 or better (2-tailed t-test) for datapoints below −700 mV and above 1200 mV.

    Reported statistics
    • 2-tailed t-test, p < 0.05 (n = 7 cells with Gd3+, 5 control cells)
    Result

    The Gd3+ cells and parallel controls of Fig. 5A are not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    For most datapoints, Gd3+ reduced the electroporation-induced effective membrane conductivity 2 to 3-fold.

    Uses the Fig. 5A Gd3+ and control datapoints, which are not in the dandiset (it also depends on…

    Data missing from the datasetFigure 5C; Results 3.5, paragraph 4uses data from outside the datasetfig5c-gd-reduces-conductivity
    From the paper

    For most datapoints, Gd3+ reduced the electroporation- induced effective conductivity 2–3-fold.

    Result

    Uses the Fig. 5A Gd3+ and control datapoints, which are not in the dandiset (it also depends on fig5b-conductivity-calibration, which was tested). The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    A single 1-us pulse caused clear Ca2+ entry at 1000 and 1200 V/cm, with the signal elevated through 5 min; the small rise at 780 V/cm was not significant.

    The Fluo-4 Ca2+ imaging of Fig. 6A is not in the dandiset, which holds strobe images only.

    Data missing from the datasetFigure 6A; Results 3.6, paragraph 2fig6a-ca-single-pulse
    From the paper

    Exposure to a single 1-μs pulse at escalating field strengths, from 0 to 1200 V/cm established a clear peak of Ca2+ entry at 1000 and 1200 V/ cm, and Ca2+ signal remained elevated through the 5-min observation period (Fig. 6A). A subtle ΔF increase after exposure at 780 V/cm was at the detection limit and not statistically significant.

    Result

    The Fluo-4 Ca2+ imaging of Fig. 6A is not in the dandiset, which holds strobe images only. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    After a train of sixty 1-us pulses at 6 Hz, 28% of cells responded strongly at 780 V/cm and nearly all at higher field strengths.

    The Fluo-4 Ca2+ imaging of Fig. 6B (224 cells) is not in the dandiset.

    Data missing from the datasetFigure 6B; Results 3.6, paragraph 3fig6b-ca-train-responders
    From the paper

    A strong Ca2+ response was recorded in 28% of cells exposed at 780 V/cm and in nearly all cells at higher intensities (Fig. 6B).

    Result

    The Fluo-4 Ca2+ imaging of Fig. 6B (224 cells) is not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    At 650 V/cm only 2 cells (5.9%) responded strongly, yet the mean Ca2+ signal at the end of recording differed from zero (p < 0.001) and was marginally higher than at 230 V/cm (p < 0.05).

    The Fluo-4 Ca2+ imaging of Fig. 6B is not in the dandiset.

    Data missing from the datasetFigure 6B; Results 3.6, paragraph 3fig6b-ca-650
    From the paper

    At 650 V/cm, only 2 cells (5.9%) showed a strong response, but the mean Ca2+ signal by the end of recording was significantly different from zero (p < 0.001, one sample t-test) and marginally higher than after exposure at 230 V/cm (p < 0.05, single-tailed t-test).

    Reported statistics
    • 650 V/cm mean signal at the end of recording against zero: one sample t-test, p < 0.001 (n = about 34 cells (2 cells are 5.9%))
    • 650 against 230 V/cm: single-tailed t-test, p < 0.05
    Result

    The Fluo-4 Ca2+ imaging of Fig. 6B is not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    A 150 V/cm test pulse 5 us after the conditioning pulse charged the poles as in undamaged cells after conditioning up to 760 V/cm, to about 80% (not significant) after 1000 V/cm, and to about 70% and 50% after 1200 and 1400 V/cm, a persistent permeabilization.

    Every file states a single pulse; the two-pulse experiments with a 150 V/cm test pulse (Fig.

    Data missing from the datasetFigure 7A and 7B, bottom panels; Results 3.7, paragraphs 3 and 5fig7ab-test-pulse-recovery
    From the paper

    Polarization still followed a cosine function after conditioning PEFs of up to 1000 V/cm. However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles, indicating a persistent membrane permeabilization ... In contrast, measurements 6 μs later (test pulse) did not differ from the control up to 760 V/cm strength of the conditioning PEF; they were at ~80% of the control reading after 1000 V/cm conditioning PEF but the difference was not statistically significant. Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test).

    Reported statistics
    • 1200 V/cm conditioning, test pulse against control: two-sided t-test, p < 0.05 (n = 5 cells)
    • 1400 V/cm conditioning, test pulse against control: two-sided t-test, p < 0.01 (n = 5 cells)
    Result

    Every file states a single pulse; the two-pulse experiments with a 150 V/cm test pulse (Fig. 7A) are not in the dandiset. The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    Within 6 us of the electroporating pulse, effective membrane conductivity at the poles fell by a factor of about 10 (range 7 to 20) for most datapoints; the cathodic pole, more conductive during the pulse, no longer differed from the anodic pole at the test pulse.

    Needs the test-pulse data of Fig. 7A/B, which are not in the dandiset (depends on fig7ab-test-pulse-recovery).

    Data missing from the datasetFigure 7C; Results 3.7, paragraph 7fig7c-fast-conductivity-drop
    From the paper

    Fig. 7C shows a profound reduction in the λm,eff within just 6 μs after the electroporating pulse. For most datapoints, it dropped by a factor of 10 (range: 7–20). While the cathodic pole became more conductive than the anodic pole during the electroporating pulse ... no difference between the poles was detected by the test pulse.

    Result

    Needs the test-pulse data of Fig. 7A/B, which are not in the dandiset (depends on fig7ab-test-pulse-recovery). The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

  • Blocked

    After mildly electroporating 570 and 760 V/cm pulses the membrane resealed fully within 6 us; after stronger pulses a residual conductivity increase persisted.

    Needs the test-pulse data of Fig. 7A/B, which are not in the dandiset (depends on fig7ab-test-pulse-recovery).

    Data missing from the datasetFigure 7C; Results 3.7, paragraph 7fig7c-full-reseal-mild
    From the paper

    For mildly electroporating PEFs of 570 and 760 V/cm, membrane resealed fully (within the accuracy of measurements) within just 6 μs. With more intense PEFs, the residual increased conductivity persisted for at least 6 μs, indicating the formation of more stable membrane lesions.

    Result

    Needs the test-pulse data of Fig. 7A/B, which are not in the dandiset (depends on fig7ab-test-pulse-recovery). The paper says its data are available on request; the only other dandiset naming the paper, 001518, is by its title and description a FluoVolt and Di-8-ANEPPS comparison at varying field strengths, and its files were not read.

Attempt semenov-2026-04, on DANDI:001518 version 0.261006.1957

Reproducing Semenov et al. (2026) from dandiset 001518 15 Open in Colab

Reproduced1

  • Reproduced

    With Di-8-ANEPPS, responses to pulses of 780 V/cm and above decreased gradually within each set of 60 images.

    Under the top mapping the cathodic |dF| at the end of the pulse images is below the start in every set from…

    Figure 2B; Results 3.2, paragraph 3verifier disagreed at firstrests on an assumptionfig2b-di8-decline-within-set
    From the paper

    In addition, responses to PEFs at and above 780 V/cm decreased gradually in each set of 60 images, consistent with expectations of adding membrane damage by additional electroporation pulses in each set

    Result

    Under the top mapping the cathodic |dF| at the end of the pulse images is below the start in every set from 780 V/cm under every cell reading and both windows (experiment means, 10-image windows, 19.8 to 17.1, 22.2 to 19.7, 24.4 to 20.8 and 27.0 to 22.4%; p 0.034, 0.069, 0.037, 0.142). The anodic pole declines in none of these sets with experiment means and 10-image windows, so reading (d) fails; reading (c) is adopted. Drift control: below 780 V/cm the cathodic |dF| also falls within the set in 9 of 11 sets (mean -1.76%); from 780 V/cm by -3.32% on average, of which -2.15% is an offset shared by both poles and -1.17% the polarization amplitude. Most of the decline is a drift present at every field strength. The criterion holds at every factor from 5.6 to 8 in the sweep; below 5.6 there is no 1400 V/cm set.

    Deviations from the paper’s method
    • The text does not name the pole; reading (c), the cathodic pole, is assumed, as the paper places the damage at the cathodic pole (Results 3.1, the cathodic pole dims at 780 V/cm; Results 3.4, the reduction is more pronounced at the cathodic pole). Reading (d) is shown.
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.

Partially reproduced2

  • Partially reproduced

    Di-8-ANEPPS dF kept increasing with field strength up to 570 V/cm at both poles.

    Under the top mapping, with experiment means, both poles rise at every step from 150 to 570 V/cm (cathodic…

    Figure 2B; Results 3.2, paragraph 3verifier disagreed at firstrests on an assumptionfig2b-di8-climbs-to-570
    From the paper

    This dye has a lower sensitivity to membrane polarization (note the vertical scale different from Fig. 2A), but ΔF kept climbing up to the electric field strength of 570 V/cm at both cell poles.

    Result

    Under the top mapping, with experiment means, both poles rise at every step from 150 to 570 V/cm (cathodic -1.6, 2.7, 6.6, 13.0%; anodic -6.2, -7.7, -10.6, -16.7%), as they do over all cells and without background subtraction. With the cell nearest the centre the anodic pole falls from 150 to 230 V/cm (-5.7 to -4.5%). The step from 43 V/cm cannot be tested, as that level has no set. In the factor sweep the criterion holds at every factor from 2 to 8; below 2 there is no 570 V/cm set.

    Deviations from the paper’s method
    • Under the top mapping the 43 V/cm level has no set, so the steps are tested from 150 V/cm.
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Partially reproduced

    By Eq. (2), the effective membrane conductivity barely affects charging while it stays far below cytosol and medium conductivities; a 10-fold rise reduces IMP by about 2% and a 100-fold rise by 12%.

    Eq. (2) with the constants of Methods 2.3 gives f = 1.498 for the intact membrane.

    Figure 5B; Results 3.5, paragraph 3fig5b-conductivity-calibration
    From the paper

    its 10-fold increase would go unnoticed, yielding just a ~2% IMP reduction, and a 100-fold increase would reduce IMP by just 12%.

    Result

    Eq. (2) with the constants of Methods 2.3 gives f = 1.498 for the intact membrane. A 10-fold rise reduces IMP by 1.33% under reading (a) and 1.20% under (b), against 2 +- 0.2; a 15.2-fold rise is needed for 2%. A 100-fold rise gives 11.87% and 11.75%, within 12 +- 1.2. The qualitative point holds, with 3.9% at 30-fold.

Not reproduced12

  • Not reproduced

    Fitted linearly through the origin over -150 to +150 mV IMPC, FluoVolt changes by 26% and Di-8-ANEPPS by 9.1% dF per 100 mV, with correlation coefficients 0.96 and 0.78.

    Under the adopted reading (top mapping, background subtracted, equal-area radius, all responding cells, the…

    Figure 3 and legend; Results 3.3, paragraph 1verifier disagreed at firstrests on an assumptionuses data from outside the datasetfig3-dye-sensitivity
    From the paper

    The correlation coefficients of the fits equaled 0.96 for FluoVolt and 0.78 for Di-8 ANEPPS (due to a lower signal-to-noise ratio), with respective slope coefficients of 26% and 9.1% ΔF per 100 mV of IMP.

    Result

    Under the adopted reading (top mapping, background subtracted, equal-area radius, all responding cells, the four sets from 140 to 336 V/cm) FluoVolt gives 6.10% dF per 100 mV (26 +- 2.6) with r 0.775 (Pearson) and 0.743 (uncentred), against 0.96 +- 0.096, and Di-8-ANEPPS 2.37% (9.1 +- 0.91) with r 0.481 and 0.402 (0.78 +- 0.078). Over the 16 top-mapping readings the slopes are 2.72 to 6.10 and 0.83 to 2.37; by experiment 5.36 to 6.64 and 2.20 to 2.53. The slope falls as the factor rises, but not as one over the factor, because the sets at or below 360 V/cm change with it. On a grid from 1.40 to 2.30 V/cm per V in steps of 0.02 the FluoVolt slope is within tolerance at 1.40 to 1.76 and the Di-8-ANEPPS slope at 1.82 to 2.16, with r within tolerance for both dyes throughout (0.90 to 0.92 and 0.79 to 0.84); no factor on that grid or in the sweep from 1.5 to 8 meets the criterion for both dyes, so the result is not reproduced at the factors run. The factors matching each slope, about 1.4 to 2.2, are near the 1.5 to 1.6 implied by the low-field response and below the 4.64 to 7.19 of the electrode geometry. Under the bottom variant, which was set from this same response, the slopes are 23.98 and 10.52 with r 0.908 and 0.824. None of 32 readings meets the criterion for both dyes. With the edge trace the slopes are 4.5 and 1.8 at the adopted factor.

    Deviations from the paper’s method
    • The pulse is given in volts; the factor to V/cm is assumed to be 5.6 V/cm per V (1400 V/cm at 250 V, the top mapping). A two-dimensional model of the electrodes of Methods 2.2 (rods 0.5 mm in diameter, 1.6 mm apart) gives 4.64 to 7.19 V/cm per V at the midpoint, depending on whether 1.6 mm is the gap or the centre distance. The bottom mapping (43 V/cm at 25 V, 1.72 V/cm per V) matches the paper's dye sensitivities, which fig3-dye-sensitivity tests, and is run as a variant. Every criterion is also run over factors from 1.5 to 8 V/cm per V.
    • Each field of view holds 3 to 6 cells; the paper used one cell per experiment and does not say which. Experiment means (adopted), the cell nearest the image centre and all cells are run.
    • The membrane trace is found automatically (peak of the baseline image along rays from the cell centre, 6 samples 1 pixel apart), not drawn by hand; 360 points at equal angles stand for the resampling along the perimeter (Methods 2.3). In some cells the trace is drawn inwards by bright spots inside the cell, and one object in c7 is two touching cells; a trace that follows the cell edge is run as a variant over every criterion and changes no result at the adopted factor.
    • Pixel size 0.267 um (16-um camera pixels over the 60x objective of Methods 2.3) is assumed; the files give none. The mean radius is 6.7 um with the peak trace and 9.9 um with the edge trace, against the about 8 um the paper uses in Eq. (2).
    • Frame 0 and other dark frames (laser misfires) are left out, so most baselines have 39 images.
    • Background subtraction (median of cell-free pixels of the same image) is adopted; the paper states it only for Ca2+ imaging (Methods 2.4). No subtraction and the camera offset alone are run as variants.
  • Not reproduced

    FluoVolt departed from linearity from about +-200 mV IMPC, while Di-8-ANEPPS stayed nearly linear from -500 to +500 mV; so FluoVolt's early departure reflects its dynamic range, not electroporation.

    Under the top mapping the FluoVolt smooth does not depart from the line at |IMPC| of 220 mV and above under…

    Figure 3 and legend; Results 3.3, paragraph 1rests on an assumptionuses data from outside the datasetfig3-fluovolt-nonlinear
    From the paper

    The actual measurements with FluoVolt gradually became non-linear already at ±200 mV, while those for Di-8-ANEPPS stayed essentially linear throughout the tested range from −500 to +500 mV.

    Result

    Under the top mapping the FluoVolt smooth does not depart from the line at |IMPC| of 220 mV and above under any LOWESS span (0 of 48 grid points; 12 of 42 with 50-mV bins); it lies above the line (107 to 113% of it at +220 mV, 128 to 134% at -220 mV). Di-8-ANEPPS departs at 22 to 23 grid points under every smooth, near zero on the positive side, from the uniform bleaching offset. With each profile's offset removed FluoVolt still does not depart, and Di-8-ANEPPS departs under span 0.3 and bins but not under 0.5 and 0.75. Under the bottom variant FluoVolt departs from 220 mV under every smooth, but Di-8-ANEPPS departs at 58 to 64 points (40 to 50 with the offset removed). No factor from 1.5 to 8 meets the criterion.

    Deviations from the paper’s method
    • Points, line and readings as in fig3-dye-sensitivity (adopted reading); LOWESS with delta of 1% of the IMPC range, a standard speed-up.
    • The fit through the origin keeps the uniform bleaching offset of each profile, as the paper reports bleaching in its own Di-8-ANEPPS dF (Results 3.2, paragraph 3); removing it is run as a variant.
  • Not reproduced

    With FluoVolt, pole dF rose with field strength until it saturated at 66% (255 mV) at 360 V/cm at the cathodic pole and -83% (-320 mV) at 570 V/cm at the anodic pole; stronger fields did not increase the anodic response and decreased the cathodic one.

    Under the top mapping the per-image cathodic dF at 360 V/cm is 23.5% (experiment means; 20.1 for the cell…

    Figure 2A; Results 3.2, paragraph 2fig2a-fluovolt-saturation
    From the paper

    ΔF increased proportionally to the electric field strength until reaching apparent saturation at 66% ΔF (255 mV IMP) at 360 V/cm at the cathodic pole, and −83% ΔF (−320 mV IMP) at 570 V/cm at the anodic pole. Further escalation of the electric field strength did not increase the dye response at the anodic pole and even decreased it at the cathodic pole.

    Result

    Under the top mapping the per-image cathodic dF at 360 V/cm is 23.5% (experiment means; 20.1 for the cell nearest the centre, 24.1 over all cells) against 66 +- 6.6, and the anodic value at 570 V/cm -35.8% (-33.7, -38.6) against -83 +- 8.3. The cathodic maximum is 35.9% at 570 V/cm. Over all 19 sets the largest experiment-mean cathodic value is 36.1% and the most negative anodic -49.5%; per experiment 43.6% and -61.1%. With the camera offset as background 17.3% and -25.2%, without background 12.1% and -17.9%. The trace check (rings within 3 pixels of the trace, and the edge trace) does not bring the means near the paper's values. The magnitudes fail under every factor from 1.5 to 8.

    Deviations from the paper’s method
    • The mean of per-image dF over the pulse images equals the collapsed-image dF, as both use the same F0; the Fig. 2 and Fig. 4 measures coincide.
    • FluoVolt n is 5 experiments here, against 4 in the paper.
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    FluoVolt measurements were stable without pulses (no significant bleaching or photosensitization), and the response within each set stayed stable through the 60 pulses, even at 1000 V/cm and above.

    In the baseline images (top mapping, experiment means, sets at the paper's levels, 10-image windows) the…

    Figure 2A; Results 3.2, paragraph 2rests on an assumptionquestion to the readerfig2a-fluovolt-stable
    From the paper

    Without PEF (first 40 datapoints, or ~ 7 s in each set), measurements were stable, indicating no significant photosensitization or dye bleaching ... but the dye response in each set stayed stable through the 60 pulses applied

    Result

    In the baseline images (top mapping, experiment means, sets at the paper's levels, 10-image windows) the cathodic pole changes by -3.34% at 780 V/cm (2-tailed paired t-test p = 0.018, n = 5) and -2.82% at 1000 V/cm (p = 0.003); the other 14 changes lie between -3.04% and +0.64%. Across readings 1 to 4 of 16 baseline tests at the levels and 4 to 9 of 38 over all sets are significant; with experiment means over all sets 4 of 38 (about 1.9 expected by chance), and 32 of 38 changes are negative, a small bleaching drift. In the pulse images at 1000 to 1400 V/cm none of 6 tests differs with experiment means (changes -0.78 to -2.01%, p 0.09 to 0.54), 0 or 1 under other readings. The criterion counts any significant baseline change. In the factor sweep it is met only at 3.5 V/cm per V (at 8 with the edge trace).

    Deviations from the paper’s method
    • The sets are those nearest the paper's levels; all 19 sets are shown as a variant.
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    FluoVolt measured and calculated IMP matched only at 43 and 150 V/cm; with stronger 1-us pulses the pole dF peaked at 71 +- 10% (cathodic) and -83.5 +- 5% (anodic), about +260 and -330 mV.

    Under the top mapping the largest mean cathodic dF over levels is 35.9% (570 V/cm; 34.4 and 35.7 under the…

    Figure 4A; Results 3.4, paragraph 1uses data from outside the datasetfig4a-fluovolt-limits
    From the paper

    However, this assumption held only for the applied fields of 43 and 150 V/cm, where measured and calculated IMP matched. With stronger PEFs, maximum ΔF reached 71 ± 10% and −83.5 ± 5% at the cathodic and anodic poles, respectively.

    Result

    Under the top mapping the largest mean cathodic dF over levels is 35.9% (570 V/cm; 34.4 and 35.7 under the other cell readings) against 71 +- 10, and the most negative anodic value -49.5% (1200 V/cm; -49.9, -51.1) against -83.5 +- 5; under the bottom variant 31.7 to 35.8% and -48.8 to -51.1%. There is no 43 V/cm set under the top mapping; at 150 V/cm measured IMP is already below IMPC (ratios 0.10 and 0.20, paired p < 0.001 and 0.001), so the match fails there. Measured IMP is below IMPC at every level from 230 V/cm (ratios 0.06 to 0.25). No factor from 1.5 to 8 meets the maxima.

    Deviations from the paper’s method
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    FluoVolt cathodic polarization fell from 71% at 360 V/cm to 45 to 50% at 1000 to 1400 V/cm.

    The cathodic dF at 360 V/cm is 23.5% under the top mapping (20.1 and 24.1 under the other cell readings; 25.5…

    Figure 4A; Results 3.4, paragraph 1fig4a-fluovolt-cathodic-decline
    From the paper

    Notably, polarization at the cathodic pole decreased from 71% at 360 V/cm to 45–50% at 1000–1400 V/cm, indicating that the more severe membrane damage prevented its polarization to the maximum.

    Result

    The cathodic dF at 360 V/cm is 23.5% under the top mapping (20.1 and 24.1 under the other cell readings; 25.5 to 27.7% under the bottom variant) against 71 +- 10. At 1000, 1200 and 1400 V/cm it is 28.9, 25.5 and 21.2% (experiment means; the second measured value is their mean), outside 40.5 to 55%. The largest mean cathodic dF of any set is 36.1%, below the 61% bound, so no factor meets it.

    Deviations from the paper’s method
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    With Di-8-ANEPPS and 1-us pulses, measured IMP fell below the calculated value at 570 V/cm, where dF peaked at 57 +- 14% (cathodic) and -55 +- 4% (anodic), over 600 mV.

    Under the top mapping Di-8-ANEPPS pole dF is largest at 1400 V/cm (24.3% and -29.2%, experiment means), not at…

    Figure 4B; Results 3.4, paragraph 2verifier disagreed at firstuses data from outside the datasetfig4b-di8-limits
    From the paper

    The measured IMP decreased below the calculated value when the electric field reached 570 V/cm, concurrently with reaching the maximum ΔF of 57 ± 14% at the cathodic pole and − 55 ± 4% at the anodic pole. These values corresponded to membrane polarization by over 600 mV, which is twice the value measured with FluoVolt.

    Result

    Under the top mapping Di-8-ANEPPS pole dF is largest at 1400 V/cm (24.3% and -29.2%, experiment means), not at 570 V/cm (13.0% and -16.7%), against 57 +- 14 and -55 +- 4. Measured IMP is below IMPC at every level, including 150 to 360 V/cm (ratios -0.14 to 0.54), so the second condition fails too. The largest Di-8-ANEPPS means of any set are 24.3% and -29.2%, so no factor meets the magnitudes; with the edge trace they are 25.1% and -30.4%.

    Deviations from the paper’s method
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    Averaged over only the first 10 of the 60 pulses, Di-8-ANEPPS cathodic polarization reached 66 +- 15% (710 +- 200 mV), so the 600-mV maximum is not the dye's limit.

    Over the first 10 pulse images the largest mean cathodic dF is 27.0% (top mapping, 1400 V/cm, experiment…

    Figure 4B, dotted lines; Results 3.4, paragraph 3verifier disagreed at firstfig4b-first-10-pulses
    From the paper

    Polarization measured this way reached 66 ± 15% (710 ± 200 mV) at the cathodic pole, suggesting that the 600-mV maximum, averaged from 60 PEFs, was not the dye limit but the actual IMP

    Result

    Over the first 10 pulse images the largest mean cathodic dF is 27.0% (top mapping, 1400 V/cm, experiment means; 21.0 for the cell nearest the centre) against 66 +- 15. It is above the 60-image maximum (24.3%) under every reading. The largest first-10 value of any set is 27.0%, so no factor meets the criterion.

    Deviations from the paper’s method
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    Above 780 V/cm the pole IMP fell progressively with field strength, more at the cathodic pole; at 1400 V/cm the cathodic pole no longer charged and the anodic pole fell to about -30% dF (-330 mV).

    Under the top mapping both poles keep growing from 780 to 1400 V/cm (cathodic 18.1, 20.4, 22.5, 24.3%; anodic…

    Figure 4B; Results 3.4, paragraph 4verifier disagreed at firstrests on an assumptionfig4b-cathodic-asymmetry
    From the paper

    As the electric field increased further, the IMP reached at the poles progressively decreased, and the reduction was more pronounced at the cathodic pole ... At 1400 V/cm, charging was no longer detectable at the cathodic pole (i.e., the membrane became fully permeable) and dropped to ~30% ΔF (~ −330 mV) at the anodic pole.

    Result

    Under the top mapping both poles keep growing from 780 to 1400 V/cm (cathodic 18.1, 20.4, 22.5, 24.3%; anodic -21.2, -25.7, -27.8, -29.2%, experiment means), so condition (1) fails under every cell reading. The cathodic value at 1400 V/cm differs from zero (p < 0.001; 0.053 for the cell nearest the centre), and the anodic -29.2% is within -30 +- 3. No factor from 5 to 8 meets the criterion; below 5 there is no 1400 V/cm set.

    Deviations from the paper’s method
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    Membrane regions nearer the equator were unaffected by pole electroporation and followed the cosine dependence of the Schwan equation up to 1000 V/cm.

    Under the top mapping measured IMP in the arcs beside the equator is below IMPC at 570, 780 and 1000 V/cm in…

    Figure 4C and legend; Results 3.4, paragraph 4verifier disagreed at firstrests on an assumptionuses data from outside the datasetfig4c-equator-follows-cosine
    From the paper

    Membrane areas closer to the equator ... appeared relatively unaffected and followed the cosine dependence predicted by Schwan formula up to 1000 V/cm (Fig. 4C).

    Result

    Under the top mapping measured IMP in the arcs beside the equator is below IMPC at 570, 780 and 1000 V/cm in most arcs (ratios -0.15 to 0.82 over readings); of 12 arc-level tests per reading, 9 to 11 differ with 15-degree arcs and all 12 with 30-degree arcs. The arcs on the cathode side of 90 degrees read about zero or negative (ratios -0.13, 0.10, 0.04 with experiment means and 15-degree arcs) where IMPC is positive. No factor in the sweep meets the criterion.

    Deviations from the paper’s method
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    With Di-8-ANEPPS and 1-us pulses, polarization grows with field strength up to 570 V/cm; at 780 V/cm the cathodic pole stops increasing and dims, and at 1000 to 1400 V/cm the poles show reduced or absent polarization while regions nearer the equator stay polarized and may polarize more than the poles.

    Under the top mapping the mean cathodic dF at 780 V/cm (18.1%) is above that at 570 V/cm (13.0%), so condition…

    Figure 1 and its legend; Results 3.1, paragraph 1verifier disagreed at firstrests on an assumptionfig1-pole-dimming
    From the paper

    At a higher electric field strength of 780 V/cm, polarization at the cathodic pole does not further increase but dims out, indicating a less efficient charging of the partially permeabilized membrane. Still stronger electric fields produce a distinct pattern of reduced or absent polarization at the poles ... while regions closer to the equator remain relatively intact and may polarize more than the poles

    Result

    Under the top mapping the mean cathodic dF at 780 V/cm (18.1%) is above that at 570 V/cm (13.0%), so condition (1) fails under every cell and background reading (10.6 against 12.1% for the cell nearest the centre; 7.4 against 9.9% without background). At 1400 V/cm the peak of the cathode-facing hemisphere lies 12 to 46 degrees from the pole, so condition (2) holds. No factor from 5 to 8 meets the criterion; below 5 there is no 1400 V/cm set.

    Deviations from the paper’s method
    • Figure 1's cell is not identified; the Di-8-ANEPPS escalation cells are used, as the criterion says.
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.
  • Not reproduced

    Normalized to 150 V/cm, pole polarization during the conditioning pulse fell 1.5 times below linear scaling at 560 V/cm and 2-fold at 760 V/cm, and further at stronger fields (p < 0.01 for every point from 560 V/cm).

    Under the top mapping, normalized to the 150 V/cm set (25 V), no reading meets the criterion.

    Figure 7B, top panels; Results 3.7, paragraph 5verifier disagreed at firstrests on an assumptionfig7b-charging-during-pulse
    From the paper

    Actual measurements fell 1.5 times below this line for 560 V/cm PEFs, 2- fold for 760 V/cm PEFs, and diverged further for more intense PEFs (p < 0.01 for all datapoints ≥560 V/cm, one sample t-test).

    Reported statistics
    • one sample t-test, p < 0.01 (n = 5 cells)
    Result

    Under the top mapping, normalized to the 150 V/cm set (25 V), no reading meets the criterion. At 25 V both poles share a bleaching offset (mean of the poles -3.9% in Di-8-ANEPPS), which makes the anodic |dF| at 150 V/cm too large and the cathodic one too small. The anodic pole with experiment means and per-cell normalization (the measured values) gives 1.46 at 560 V/cm (1.5 +- 0.15) and 1.62 at 760 V/cm (2 +- 0.2), and 1.72, 1.76 and 2.08 at 1000 to 1400 V/cm, so it exceeds 2 only at 1400; every datapoint of that reading is below the line at p < 0.01. Its values are nearest the paper's, but it is the reading the offset affects most. The cathodic ratios are 0.63 to 0.94. The mean of the poles, in which the offset cancels, gives 0.55 to 0.85 with experiment means, so the measured polarization lies above the linear line. With per-cell normalization over all cells the mean of the poles gives ratios such as -10.7 and 16.9, because the 150 V/cm values are near zero; those ratios carry no information. Only factors 5.6 and 6.25 have every level, and neither meets the criterion.

    Deviations from the paper’s method
    • The 560 and 760 V/cm of Results 3.7 are the 570 and 780 V/cm sets (claims file header).
    • Factor, cell, trace, pixel and background choices as in fig3-dye-sensitivity.

Not tested in a notebook 15

15 data missing from the dataset

Blocked15

  • Blocked

    Repeated alternating sets at 150 and 230 V/cm (480 pulses and 800 flashes) gave dF responses constant within and between sets.

    The alternating 150 and 230 V/cm protocol (n = 8) is not in the dandiset; every subject holds one escalation…

    Data missing from the datasetFigure 2C and 2D; Results 3.2, paragraph 4fig2cd-stable-before-electroporation
    From the paper

    Repeated sets of PEFs at 150 and 230 V/cm, delivered in alternation, produced ΔF responses that stayed constant both within each set and between the sets (Fig. 2C and D).

    Result

    The alternating 150 and 230 V/cm protocol (n = 8) is not in the dandiset; every subject holds one escalation with each voltage once.

  • Blocked

    At 1000 V/cm the cathodic pole dF fell from 40 +- 10% at the start of the set to 26.6 +- 8% at its end, a trend that was not statistically significant.

    Part of the alternating protocol of Fig. 2C, which is not in the dandiset.

    Data missing from the datasetFigure 2C; Results 3.2, paragraph 4fig2c-1000-within-set
    From the paper

    In contrast, at an electroporating field strength of 1000 V/cm, ΔF at the cathodic pole decreased from 40 ± 10% at the beginning of the set to 26.6 ± 8% at the end of it. Although not statistically significant (p > 0.05)

    Reported statistics
    • 2-tailed paired t-test (named in the Fig. 2 legend), p > 0.05 (n = 8 cells)
    Result

    Part of the alternating protocol of Fig. 2C, which is not in the dandiset.

  • Blocked

    Set-averaged dF stayed nearly constant before the 1000 V/cm exposure but was about 20% lower in the sets after it.

    Part of the alternating protocol of Fig. 2C and D, which is not in the dandiset.

    Data missing from the datasetFigure 2D and legend; Results 3.2, paragraph 4question to the readerfig2d-lasting-reduction
    From the paper

    ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05).

    Reported statistics
    • 2-tailed paired t-test, p < 0.05 (n = 8 cells)
    Result

    Part of the alternating protocol of Fig. 2C and D, which is not in the dandiset.

  • Blocked

    With 0.3-us pulses at higher fields (357 to 3320 V/cm), imaged at 275 ns, the maximum dF was 53 +- 4% (about 600 mV) at both poles, as with 1-us pulses, and the response changed with field strength in the same way.

    Every file states a 1-us pulse; the 0.3-us experiments (n = 10) are not in the dandiset.

    Data missing from the datasetFigure 4D; Results 3.4, paragraph 5fig4d-short-pulses-same-limit
    From the paper

    Contrary to the expectations, the results were similar to those with 1-μs pulses in Fig. 4B: the maximum ΔF reached was 53 ± 4% (~600 mV) at both cell poles. The pattern of how the response changed with increasing PEF strength was not different from that with 1-μs PEFs either.

    Result

    Every file states a 1-us pulse; the 0.3-us experiments (n = 10) are not in the dandiset.

  • Blocked

    With 1 mM Gd3+ the anodic pole charged to -864 +- 44 mV, against -542 +- 57 mV in parallel controls (p < 0.001).

    No file mentions Gd3+; the Gd3+ (n = 7) and parallel control (n = 5) experiments are not in the dandiset.

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 1fig5a-gd-extends-anodic
    From the paper

    Indeed, we found that 1 mM Gd3+ extended the range of membrane charging at the anodic pole down to −864 ± 44 mV (p < 0.001 compared to −542 ± 57 mV in parallel control experiments, Fig. 5A).

    Reported statistics
    • 2-tailed t-test (Fig. 5 legend), p < 0.001 (n = 7 cells with Gd3+, 5 control cells)
    Result

    No file mentions Gd3+; the Gd3+ (n = 7) and parallel control (n = 5) experiments are not in the dandiset.

  • Blocked

    With Gd3+, the measured IMP stayed nearly identical to IMPC down to -780 mV, so the Di-8-ANEPPS calibration holds at high IMPs.

    The Gd3+ experiments are not in the dandiset.

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 1uses data from outside the datasetfig5a-gd-linear
    From the paper

    Furthermore, measured IMP remained nearly identical to the theoretical IMPC down to −780 mV, indicating that the dye response remained linear and its calibration was valid even at high IMPs.

    Result

    The Gd3+ experiments are not in the dandiset.

  • Blocked

    At the cathodic pole Gd3+ cells reached 647 +- 44 mV, not significantly above controls, but Gd3+ prevented the decline of IMP with stronger fields.

    The Gd3+ experiments are not in the dandiset.

    Data missing from the datasetFigure 5A; Results 3.5, paragraph 2fig5a-gd-cathodic
    From the paper

    At the cathodic pole, polarization in the presence of Gd3+ reached 647 ± 44 mV, a value not significantly higher than that in the control group without Gd3+. However, Gd3+ prevented the progressive decline in IMP as the electric field was increased.

    Result

    The Gd3+ experiments are not in the dandiset.

  • Blocked

    Gd3+ and control data differ significantly for datapoints with IMPC below -700 mV and above 1200 mV.

    The Gd3+ experiments are not in the dandiset.

    Data missing from the datasetFigure 5A legenduses data from outside the datasetfig5a-gd-differences
    From the paper

    Differences between Gd3+ and control group data are significant at p < 0.05 or better (2-tailed t-test) for datapoints below −700 mV and above 1200 mV.

    Reported statistics
    • 2-tailed t-test, p < 0.05 (n = 7 cells with Gd3+, 5 control cells)
    Result

    The Gd3+ experiments are not in the dandiset.

  • Blocked

    For most datapoints, Gd3+ reduced the electroporation-induced effective membrane conductivity 2 to 3-fold.

    Uses the Gd3+ and control datapoints of Fig. 5A, which are not in the dandiset.

    Data missing from the datasetFigure 5C; Results 3.5, paragraph 4uses data from outside the datasetfig5c-gd-reduces-conductivity
    From the paper

    For most datapoints, Gd3+ reduced the electroporation- induced effective conductivity 2–3-fold.

    Result

    Uses the Gd3+ and control datapoints of Fig. 5A, which are not in the dandiset.

  • Blocked

    A single 1-us pulse caused clear Ca2+ entry at 1000 and 1200 V/cm, with the signal elevated through 5 min; the small rise at 780 V/cm was not significant.

    Fluo-4 Ca2+ imaging is not in the dandiset; every file is a 100-image strobe set with a potentiometric dye.

    Data missing from the datasetFigure 6A; Results 3.6, paragraph 2fig6a-ca-single-pulse
    From the paper

    Exposure to a single 1-μs pulse at escalating field strengths, from 0 to 1200 V/cm established a clear peak of Ca2+ entry at 1000 and 1200 V/ cm, and Ca2+ signal remained elevated through the 5-min observation period (Fig. 6A). A subtle ΔF increase after exposure at 780 V/cm was at the detection limit and not statistically significant.

    Result

    Fluo-4 Ca2+ imaging is not in the dandiset; every file is a 100-image strobe set with a potentiometric dye.

  • Blocked

    After a train of sixty 1-us pulses at 6 Hz, 28% of cells responded strongly at 780 V/cm and nearly all at higher field strengths.

    The Ca2+ imaging of 224 cells is not in the dandiset.

    Data missing from the datasetFigure 6B; Results 3.6, paragraph 3fig6b-ca-train-responders
    From the paper

    A strong Ca2+ response was recorded in 28% of cells exposed at 780 V/cm and in nearly all cells at higher intensities (Fig. 6B).

    Result

    The Ca2+ imaging of 224 cells is not in the dandiset.

  • Blocked

    At 650 V/cm only 2 cells (5.9%) responded strongly, yet the mean Ca2+ signal at the end of recording differed from zero (p < 0.001) and was marginally higher than at 230 V/cm (p < 0.05).

    The Ca2+ imaging is not in the dandiset.

    Data missing from the datasetFigure 6B; Results 3.6, paragraph 3fig6b-ca-650
    From the paper

    At 650 V/cm, only 2 cells (5.9%) showed a strong response, but the mean Ca2+ signal by the end of recording was significantly different from zero (p < 0.001, one sample t-test) and marginally higher than after exposure at 230 V/cm (p < 0.05, single-tailed t-test).

    Reported statistics
    • 650 V/cm mean signal at the end of recording against zero: one sample t-test, p < 0.001 (n = about 34 cells (2 cells are 5.9%))
    • 650 against 230 V/cm: single-tailed t-test, p < 0.05
    Result

    The Ca2+ imaging is not in the dandiset.

  • Blocked

    A 150 V/cm test pulse 5 us after the conditioning pulse charged the poles as in undamaged cells after conditioning up to 760 V/cm, to about 80% (not significant) after 1000 V/cm, and to about 70% and 50% after 1200 and 1400 V/cm, a persistent permeabilization.

    The two-pulse protocol (conditioning pulse, then a 150 V/cm test pulse) is not in the dandiset; every file…

    Data missing from the datasetFigure 7A and 7B, bottom panels; Results 3.7, paragraphs 3 and 5fig7ab-test-pulse-recovery
    From the paper

    Polarization still followed a cosine function after conditioning PEFs of up to 1000 V/cm. However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles, indicating a persistent membrane permeabilization ... In contrast, measurements 6 μs later (test pulse) did not differ from the control up to 760 V/cm strength of the conditioning PEF; they were at ~80% of the control reading after 1000 V/cm conditioning PEF but the difference was not statistically significant. Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test).

    Reported statistics
    • 1200 V/cm conditioning, test pulse against control: two-sided t-test, p < 0.05 (n = 5 cells)
    • 1400 V/cm conditioning, test pulse against control: two-sided t-test, p < 0.01 (n = 5 cells)
    Result

    The two-pulse protocol (conditioning pulse, then a 150 V/cm test pulse) is not in the dandiset; every file describes a single pulse.

  • Blocked

    Within 6 us of the electroporating pulse, effective membrane conductivity at the poles fell by a factor of about 10 (range 7 to 20) for most datapoints; the cathodic pole, more conductive during the pulse, no longer differed from the anodic pole at the test pulse.

    Needs the test-pulse data of Fig. 7A, which are not in the dandiset.

    Data missing from the datasetFigure 7C; Results 3.7, paragraph 7fig7c-fast-conductivity-drop
    From the paper

    Fig. 7C shows a profound reduction in the λm,eff within just 6 μs after the electroporating pulse. For most datapoints, it dropped by a factor of 10 (range: 7–20). While the cathodic pole became more conductive than the anodic pole during the electroporating pulse ... no difference between the poles was detected by the test pulse.

    Result

    Needs the test-pulse data of Fig. 7A, which are not in the dandiset.

  • Blocked

    After mildly electroporating 570 and 760 V/cm pulses the membrane resealed fully within 6 us; after stronger pulses a residual conductivity increase persisted.

    Needs the test-pulse data of Fig. 7A, which are not in the dandiset.

    Data missing from the datasetFigure 7C; Results 3.7, paragraph 7fig7c-full-reseal-mild
    From the paper

    For mildly electroporating PEFs of 570 and 760 V/cm, membrane resealed fully (within the accuracy of measurements) within just 6 μs. With more intense PEFs, the residual increased conductivity persisted for at least 6 μs, indicating the formation of more stable membrane lesions.

    Result

    Needs the test-pulse data of Fig. 7A, which are not in the dandiset.

Attempt semenov-2026-05, on DANDI:001521 version 0.261006.1845

Reproducing Semenov et al. (2026) from dandiset 001521 6 Open in Colab

Reproduced2

  • Reproduced

    A single 1-us pulse causes clear Ca2+ entry into CHO cells at 1000 and 1200 V/cm, among field strengths escalated from 0 to 1200 V/cm.

    Under M1 (1000 and 1200 V/cm at 250 and 300 V) three of the four readings hold at both fields.

    Results, 3.6 Electroporative uptake of Ca2+, paragraph 2; Figure 6Afig6a-ca-entry-1000-1200
    From the paper

    Exposure to a single 1-μs pulse at escalating field strengths, from 0 to 1200 V/cm established a clear peak of Ca2+ entry at 1000 and 1200 V/cm

    Result

    Under M1 (1000 and 1200 V/cm at 250 and 300 V) three of the four readings hold at both fields. The end value (last 10 frames) is above the 0 V/cm group by 6.58 and 8.19% (Student's t-test p = 4.9e-09 and 3.0e-11), and the peak is above zero (2.30 and 5.35%, p = 3.3e-07 and 5.0e-07) and above the 0 V/cm peak (p = 6.1e-06 and 1.9e-08); the group means at both fields exceed those at 650 V/cm or less (0 and 150 V, at most -10.26% for the end value and 0.55% for the peak). The end value against zero fails, as it is negative at both fields (-5.44 and -3.83%), with the sham at -12.02%. Under M2 (300 and 350 V) the same three readings hold. With fields of view as the unit, the peak less the same field of view's sham is 2.42% at 250 V (4 fields of view, p = 0.0004) and 5.02% at 300 V (5, p = 0.0002). The end and peak readings compare later recordings with the sham, which is always recorded first, while the decline of the signal is steepest in the first recording (pre-pulse slope -3.97% per min in the first recording, -0.41 to -1.46% per min in the fifth to seventh). The step of dF at the pulse (5 frames after less 5 before), which this does not affect, is above the sham's at 250 V (0.35 +- 0.17%, p = 0.025) and 300 V (1.78 +- 0.31%, p = 3.2e-07), but not at 150 or 200 V (p = 0.13 and 0.10); at 250 V it is not above zero on its own (p = 0.058). So the entry at 1000 V/cm under M1 is small. The single-pulse session holds 27 cells in 6 fields of view, and three sets of fields of view give 14 cells, so the 14 cells of Fig. 6A cannot be identified. The results hold with regions of 0.5 and 1.0 of the radius and end windows of 5 and 20 frames.

    Deviations from the paper’s method
    • The files give generator voltages and the paper field strengths, with no conversion in either. Two readings are run. M1, 3.9 V/cm per V, is adopted as the main reading (an assumption, as the paper gives no conversion), because the single-pulse voltages then fall on the paper's field series 570 to 1400 V/cm and the six train voltages nearest the fields labelled in Fig. 6B (230, 570, 650, 780, 900, 1000 V/cm) have group sizes close to the n the figure gives (28, 38, 36, 68, 47, 39 against 28, 37, 34, 54, 35, 36). M2, 3.3 V/cm per V, puts the train voltages 70, 200 and 230 V on the 230, 650 and 780 V/cm named in Section 3.6 and is shown as a variant. A named field is assigned to the nearest voltage. Neither factor follows from the electrode gap (V/d is 10 V/cm per V for the 1.00 mm of the files, 6.25 for the 1.6 mm of Methods 2.2). The outcome is the same under both.
    • Cells are found by an Otsu threshold and watershed of the pre-pulse mean image, with a circular region of 0.7 of each cell's equivalent radius and the median of pixels more than 15 px from any cell as background; the paper drew the regions by hand (Methods 2.4) and these are standard choices, shown with regions of 0.5 and 1.0 of the radius, end windows of 5 and 20 frames, and a background taken as the 10th percentile of the cell-free pixels.
    • Every detected cell in every file is used, as the dataset does not say which cells the paper used.
    • The paper names no test for this panel; the claims file's readings (one-sample t-test or Student's t-test against 0 V/cm, end value or peak) are all run.
  • Reproduced

    After a single 1-us pulse at 780 V/cm the Ca2+ signal rises only subtly, at the detection limit, and not significantly.

    The criterion's test, a one-sample t-test of the end value against zero, finds no increase at 780 V/cm, with…

    Results, 3.6 Electroporative uptake of Ca2+, paragraph 2; Figure 6Aquestion to the readerfig6a-780-not-significant
    From the paper

    A subtle ΔF increase after exposure at 780 V/cm was at the detection limit and not statistically significant

    Result

    The criterion's test, a one-sample t-test of the end value against zero, finds no increase at 780 V/cm, with -7.42 +- 0.52% under M1 (200 V, n = 24) and -5.44 +- 0.55% under M2 (250 V, n = 18), one-sided p = 1 for both. That test cannot detect an increase here, as it finds none at 1000 and 1200 V/cm either (-5.44 and -3.83% under M1), so the outcome carries little information. Against the 0 V/cm group the end value is higher by 4.60% (M1, p = 1.3e-06), and the peak is 1.76 +- 0.61% (one-sample p = 0.0086; against the sham peak p = 0.021); both comparisons include the slowing of the decline with recording order. The step of dF at the pulse against the 0 V/cm group, which detects 1000 and 1200 V/cm under M1 (p = 0.025 and 3.2e-07), finds no increase at 780 V/cm under M1 (0.15 +- 0.16%, p = 0.10), and finds one under M2, where 780 V/cm is 250 V (p = 0.025). The step is the only reading not confounded by recording order, but it separates 1000 V/cm from the sham only barely (p = 0.025, and p = 0.058 against zero), and the steps at 780 and 1000 V/cm under M1 do not differ (0.15 +- 0.16 and 0.35 +- 0.17%, p = 0.40), so it is weak evidence for the absence at 780 V/cm. Whether the criterion's test can stand for the paper's is asked of a reader (questions/001521.yaml).

    Deviations from the paper’s method
    • The files give generator voltages and the paper field strengths, with no conversion in either. Two readings are run. M1, 3.9 V/cm per V, is adopted as the main reading (an assumption, as the paper gives no conversion), because the single-pulse voltages then fall on the paper's field series 570 to 1400 V/cm and the six train voltages nearest the fields labelled in Fig. 6B (230, 570, 650, 780, 900, 1000 V/cm) have group sizes close to the n the figure gives (28, 38, 36, 68, 47, 39 against 28, 37, 34, 54, 35, 36). M2, 3.3 V/cm per V, puts the train voltages 70, 200 and 230 V on the 230, 650 and 780 V/cm named in Section 3.6 and is shown as a variant. A named field is assigned to the nearest voltage. Neither factor follows from the electrode gap (V/d is 10 V/cm per V for the 1.00 mm of the files, 6.25 for the 1.6 mm of Methods 2.2). The outcome is the same under both.
    • Cells are found by an Otsu threshold and watershed of the pre-pulse mean image, with a circular region of 0.7 of each cell's equivalent radius and the median of pixels more than 15 px from any cell as background; the paper drew the regions by hand (Methods 2.4) and these are standard choices, shown with regions of 0.5 and 1.0 of the radius, end windows of 5 and 20 frames, and a background taken as the 10th percentile of the cell-free pixels.
    • Every detected cell in every file is used, as the dataset does not say which cells the paper used.

Partially reproduced1

  • Partially reproduced

    By Eq. 2, a 10-fold increase of effective membrane conductivity from 0.0003 mS/m reduces the pole IMP by only about 2%, and a 100-fold increase by 12%.

    Eq. 2 with the paper's constants gives f = 1.4801 for a 10-fold and 1.3220 for a 100-fold increase from 3e-7…

    Results, 3.5 Membrane charging in the presence of Gd3+ ions, paragraph 3; Figure 5Bfig5b-conductivity-calibration
    From the paper

    its 10-fold increase would go unnoticed, yielding just a ~2% IMP reduction, and a 100-fold increase would reduce IMP by just 12%

    Result

    Eq. 2 with the paper's constants gives f = 1.4801 for a 10-fold and 1.3220 for a 100-fold increase from 3e-7 S/m, a reduction of 1.33% of IMPC (outside 2 +- 0.2%) and 11.87% (within 12 +- 1.2%). Relative to f at the intact conductivity the reductions are 1.20 and 11.75%. This is a computation from the paper's equation and uses no recordings, so it says nothing about the dataset.

Not reproduced3

  • Not reproduced

    After a single 1-us pulse at 1000 or 1200 V/cm the Ca2+ signal stays elevated through the 5-min observation period.

    The mean dF over the last 10 frames is below zero at 1000 and 1200 V/cm under M1 (-5.44 +- 0.55% and -3.83 +…

    Results, 3.6 Electroporative uptake of Ca2+, paragraph 2; Figure 6Afig6a-ca-sustained
    From the paper

    Ca2+ signal remained elevated through the 5-min observation period

    Result

    The mean dF over the last 10 frames is below zero at 1000 and 1200 V/cm under M1 (-5.44 +- 0.55% and -3.83 +- 0.71%) and at 1000 V/cm under M2 (-3.83%); at 1200 V/cm under M2 (350 V) it is +1.24 +- 1.95%, p = 0.53. The ratio of final to peak group mean is -63 and -2.4 under M1, -2.4 and 0.18 under M2. Unpulsed cells decline to -12.0% over the same window. The decline is in the cells' own fluorescence, -8.7% before background subtraction, while the cell-free background falls by 1.0%, so no choice of background region removes it. The paper's Fig. 6A shows the 0 V/cm mean trace rising to about +1% by 300 s, so these recordings or the processing behind the figure differ in a way the paper does not describe. Against the 0 V/cm group the end value is higher by 6.6 and 8.2% under M1 (p = 4.9e-09 and 3.0e-11), and less the same field of view's sham trace it is 6.4 and 8.4% above zero (p = 7.3e-10 and 4.5e-11), but these comparisons include the change of the decline with recording order. With a background taken as the 10th percentile of the cell-free pixels the sham still falls to -11.3% and the end values stay negative (-5.06 and -3.51%). The signal stays above that of unpulsed cells to the end of the 5 min, but not above its own pre-pulse level, which is what the criterion tests. With other region sizes and end windows the end values move by less than 1% and stay negative at 250 and 300 V. The question of how the paper's traces handle the decline is for the authors (see findings).

    Deviations from the paper’s method
    • The files give generator voltages and the paper field strengths, with no conversion in either. Two readings are run. M1, 3.9 V/cm per V, is adopted as the main reading (an assumption, as the paper gives no conversion), because the single-pulse voltages then fall on the paper's field series 570 to 1400 V/cm and the six train voltages nearest the fields labelled in Fig. 6B (230, 570, 650, 780, 900, 1000 V/cm) have group sizes close to the n the figure gives (28, 38, 36, 68, 47, 39 against 28, 37, 34, 54, 35, 36). M2, 3.3 V/cm per V, puts the train voltages 70, 200 and 230 V on the 230, 650 and 780 V/cm named in Section 3.6 and is shown as a variant. A named field is assigned to the nearest voltage. Neither factor follows from the electrode gap (V/d is 10 V/cm per V for the 1.00 mm of the files, 6.25 for the 1.6 mm of Methods 2.2). The outcome is the same under both.
    • Cells are found by an Otsu threshold and watershed of the pre-pulse mean image, with a circular region of 0.7 of each cell's equivalent radius and the median of pixels more than 15 px from any cell as background; the paper drew the regions by hand (Methods 2.4) and these are standard choices, shown with regions of 0.5 and 1.0 of the radius, end windows of 5 and 20 frames, and a background taken as the 10th percentile of the cell-free pixels.
    • Every detected cell in every file is used, as the dataset does not say which cells the paper used.
  • Not reproduced

    With trains of sixty 1-us pulses at 6 Hz (each cell tested once, 224 cells), a strong Ca2+ response occurs in 28% of cells at 780 V/cm and in nearly all cells at higher fields.

    No reading meets the criterion. The fields above 780 V/cm are taken as those of Fig. 6B, 900 and 1000 V/cm…

    Results, 3.6 Electroporative uptake of Ca2+, paragraph 3; Figure 6Bfig6b-train-threshold
    From the paper

    A strong Ca2+ response was recorded in 28% of cells exposed at 780 V/cm and in nearly all cells at higher intensities

    Result

    No reading meets the criterion. The fields above 780 V/cm are taken as those of Fig. 6B, 900 and 1000 V/cm (230 and 250 V under M1, 250 and 300 V under M2). The fraction of strong responders at 780 V/cm is 2.9 to 22.1% under M1 (200 V, 68 cell exposures) and 44.7 to 78.7% under M2 (230 V, 47), against 28 +- 2.8%, over six rules, including "above 3 s.d." read literally as a threshold of 3 s.d. of the reference group. The lower of the two fractions at the higher fields is 44.7 to 78.7% under M1 and 61.5 to 79.5% under M2, against at least 90%. With regions of 0.5 and 1.0 of the radius the criterion is met in none of the 36 combinations of region, conversion and rule. The six voltage groups that correspond to the Fig. 6B fields hold 256 cell exposures under M1 (224 under M2), against 224; in all, the dataset holds 311 exposures to trains of 82 distinct cells in 9 fields of view, each recorded at 1 to 7 voltages, where the paper states 224 cells each tested once (measured gives the 780 V/cm fraction under M1 and rule (a) against 0 V/cm, and the cells in the M1 groups of the Fig. 6B fields). The figure's group sizes are close to the dataset's exposures, so the paper may have counted exposures as cells. Taking only the first train of each field of view, 9.1 to 18.2% respond at 200 V and 90.9 to 100% at 250 V (11 cells each). The end values carry the decline of the sham signal (-15.7% in the train session) that the Fig. 6B traces do not show. These numbers use the criterion's end window of 10 frames; with 5 frames and a region of 0.5 of the radius the 780 V/cm fraction under M1 and the rule above the largest of the lowest field is 27.9%, within tolerance, but the higher fields reach 76.6 and 82.1%, not 90%. With a background taken as the 10th percentile of the cell-free pixels, which dim unsegmented cells affect less (the background falls from 1.81 to 1.21 times the corrected cell signal), the criterion is met in none of 12 combinations of conversion and rule (780 V/cm 2.9 to 23.5% under M1, 42.6 to 91.5% under M2; lower higher-field fraction at most 87.2%).

    Deviations from the paper’s method
    • The files give generator voltages and the paper field strengths, with no conversion in either. Two readings are run. M1, 3.9 V/cm per V, is adopted as the main reading (an assumption, as the paper gives no conversion), because the single-pulse voltages then fall on the paper's field series 570 to 1400 V/cm and the six train voltages nearest the fields labelled in Fig. 6B (230, 570, 650, 780, 900, 1000 V/cm) have group sizes close to the n the figure gives (28, 38, 36, 68, 47, 39 against 28, 37, 34, 54, 35, 36). M2, 3.3 V/cm per V, puts the train voltages 70, 200 and 230 V on the 230, 650 and 780 V/cm named in Section 3.6 and is shown as a variant. A named field is assigned to the nearest voltage. Neither factor follows from the electrode gap (V/d is 10 V/cm per V for the 1.00 mm of the files, 6.25 for the 1.6 mm of Methods 2.2). The outcome is the same under both.
    • Cells are found by an Otsu threshold and watershed of the pre-pulse mean image, with a circular region of 0.7 of each cell's equivalent radius and the median of pixels more than 15 px from any cell as background; the paper drew the regions by hand (Methods 2.4) and these are standard choices, shown with regions of 0.5 and 1.0 of the radius, end windows of 5 and 20 frames, and a background taken as the 10th percentile of the cell-free pixels.
    • The cells were tested more than once in the dataset; all exposures are used, and the first exposure of each field of view is shown as a variant.
    • Reading (b), above 3 s.d. of the reference group, is run as above its mean plus 3 s.d. and, literally, above 3 s.d.
  • Not reproduced

    With 60-pulse trains at 650 V/cm only 2 cells (5.9%) respond strongly, but the mean Ca2+ signal at the end of recording is significantly above zero and marginally above that at 230 V/cm.

    The statement's tests fail under both conversions.

    Results, 3.6 Electroporative uptake of Ca2+, paragraph 3; Figure 6Bverifier disagreed at firstfig6b-650-weak-but-significant
    From the paper

    At 650 V/cm, only 2 cells (5.9%) showed a strong response, but the mean Ca2+ signal by the end of recording was significantly different from zero (p < 0.001, one sample t-test) and marginally higher than after exposure at 230 V/cm (p < 0.05, single-tailed t-test)

    Reported statistics
    • 650 V/cm end-of-recording signal against zero: one sample t-test, p < 0.001
    • 650 V/cm against 230 V/cm: single-tailed t-test, p < 0.05
    Result

    The statement's tests fail under both conversions. Under M1 the mean end value at 170 V (650 V/cm) is -9.17 +- 0.83%, significantly below zero (two-sided p = 6.4e-13, one-sided p = 1 for above zero), and not above the 70 V group (single-tailed p = 0.20). Under M2 the 200 V mean is -1.98 +- 1.77% (p = 0.27 against zero) and above the 70 V group (single-tailed p = 0.0023). The count is met under one combination of 36 (M1, 170 V, rule above the largest of the lowest field, region 0.7 of the radius, 2 of 36, 5.6%); measured gives the first reading, rule (a) against 0 V/cm under M1, 0 cells. Regions of 0.5 and 1.0 give 1 cell (2.8%) under the same rule, the other five rules give 0 under M1, and M2 (200 V, 68 exposures) gives 2 to 17 cells (2.9 to 25.0%). As the tests fail under both conversions and every rule, the outcome does not rest on the choice. The end values carry the decline of the sham signal. With a background taken as the 10th percentile of the cell-free pixels the 650 V/cm mean is -7.37% under M1 and -1.54% under M2 (one-sided p = 1.0 and 0.87 for above zero), and the count of 2 cells (5.9%) is met in none of 12 combinations. In round 1 this claim was blocked as methods_underspecified; the statement's tests are fully specified and fail, so it is not reproduced.

    Deviations from the paper’s method
    • The files give generator voltages and the paper field strengths, with no conversion in either. Two readings are run. M1, 3.9 V/cm per V, is adopted as the main reading (an assumption, as the paper gives no conversion), because the single-pulse voltages then fall on the paper's field series 570 to 1400 V/cm and the six train voltages nearest the fields labelled in Fig. 6B (230, 570, 650, 780, 900, 1000 V/cm) have group sizes close to the n the figure gives (28, 38, 36, 68, 47, 39 against 28, 37, 34, 54, 35, 36). M2, 3.3 V/cm per V, puts the train voltages 70, 200 and 230 V on the 230, 650 and 780 V/cm named in Section 3.6 and is shown as a variant. A named field is assigned to the nearest voltage. Neither factor follows from the electrode gap (V/d is 10 V/cm per V for the 1.00 mm of the files, 6.25 for the 1.6 mm of Methods 2.2). The outcome is the same under both.
    • Cells are found by an Otsu threshold and watershed of the pre-pulse mean image, with a circular region of 0.7 of each cell's equivalent radius and the median of pixels more than 15 px from any cell as background; the paper drew the regions by hand (Methods 2.4) and these are standard choices, shown with regions of 0.5 and 1.0 of the radius, end windows of 5 and 20 frames, and a background taken as the 10th percentile of the cell-free pixels.

Not tested in a notebook 21

21 data missing from the dataset

Blocked21

  • Blocked

    With Di-8-ANEPPS, polarization by 1-us pulses grows with field strength up to 570 to 780 V/cm; at stronger fields the poles become leaky and show reduced or absent polarization while regions near the equator stay polarized.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.1 Visualization of electroporation, paragraph 1; Figure 1fig1-pole-leakage-pattern
    From the paper

    Still stronger electric fields produce a distinct pattern of reduced or absent polarization at the poles (where the membrane becomes too leaky to accumulate the charge) while regions closer to the equator remain relatively intact and may polarize more than the poles

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    FluoVolt dF rises with field strength until it saturates at 66% (255 mV) at 360 V/cm at the cathodic pole and at -83% (-320 mV) at 570 V/cm at the anodic pole; stronger fields do not increase it at the anodic pole and decrease it at the cathodic pole.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.2 Polarization by multiple repeated stimuli, paragraph 2; Figure 2Afig2a-fluovolt-saturation
    From the paper

    ΔF increased proportionally to the electric field strength until reaching apparent saturation at 66% ΔF (255 mV IMP) at 360 V/cm at the cathodic pole, and −83% ΔF (−320 mV IMP) at 570 V/cm at the anodic pole

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    FluoVolt responses stayed stable through the 60 pulses of each set, even at 1000 V/cm and above, which electroporate strongly.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.2 Polarization by multiple repeated stimuli, paragraph 2; Figure 2Afig2a-fluovolt-stable-within-set
    From the paper

    Field strengths of 1000 V/cm and higher caused strong electroporation (see Section 3.5), but the dye response in each set stayed stable through the 60 pulses applied

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Di-8-ANEPPS dF keeps rising up to 570 V/cm at both poles, and at 780 V/cm and above it declines gradually within each set of 60 pulses.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.2 Polarization by multiple repeated stimuli, paragraph 3; Figure 2Bfig2b-di8-decline-within-set
    From the paper

    In addition, responses to PEFs at and above 780 V/cm decreased gradually in each set of 60 images

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Alternating sets at 150 and 230 V/cm give dF that stays constant within and between sets; after electroporation at 1000 V/cm the set-averaged dF drops by about 20% and stays lower.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.2 Polarization by multiple repeated stimuli, paragraph 4; Figure 2C and 2Dfig2cd-stable-then-drop
    From the paper

    ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05)

    Reported statistics
    • 2-tailed paired t-test, p < 0.05 (n = 8 cells, one per experiment)
    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    At 1000 V/cm, cathodic dF fell from 40% at the start of the set to 26.6% at its end, a trend that was not significant.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.2 Polarization by multiple repeated stimuli, paragraph 4; Figure 2Cfig2c-1000-within-set-trend
    From the paper

    ΔF at the cathodic pole decreased from 40 ± 10% at the beginning of the set to 26.6 ± 8% at the end of it. Although not statistically significant (p > 0.05)

    Reported statistics
    • p > 0.05 (n = 8 cells)
    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Fitted through the origin over -150 to +150 mV of calculated IMP, FluoVolt and Di-8-ANEPPS change emission by 26% and 9.1% per 100 mV, with correlation coefficients of 0.96 and 0.78.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.3 Calibration of the potentiometric dyes, paragraph 1; Figure 3fig3-dye-calibration
    From the paper

    The correlation coefficients of the fits equaled 0.96 for FluoVolt and 0.78 for Di-8 ANEPPS (due to a lower signal-to-noise ratio), with respective slope coefficients of 26% and 9.1% ΔF per 100 mV of IMP

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    FluoVolt becomes non-linear already at plus or minus 200 mV while Di-8-ANEPPS stays nearly linear from -500 to +500 mV, so the early departure of FluoVolt reflects its dynamic range, not electroporation.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.3 Calibration of the potentiometric dyes, paragraph 1; Figure 3fig3-fluovolt-nonlinear
    From the paper

    The actual measurements with FluoVolt gradually became non-linear already at ±200 mV, while those for Di-8-ANEPPS stayed essentially linear throughout the tested range from −500 to +500 mV

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here. It also depends on fig3-dye-calibration, blocked for the same reason.

  • Blocked

    With FluoVolt the maximum dF reached 71% and -83.5% at the cathodic and anodic poles, and cathodic polarization fell from 71% at 360 V/cm to 45 to 50% at 1000 to 1400 V/cm.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.4 Azimuthal membrane charging and polarization limits, paragraph 1; Figure 4Afig4a-fluovolt-maximum
    From the paper

    With stronger PEFs, maximum ΔF reached 71 ± 10% and −83.5 ± 5% at the cathodic and anodic poles, respectively ... polarization at the cathodic pole decreased from 71% at 360 V/cm to 45–50% at 1000–1400 V/cm

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    With Di-8-ANEPPS, measured IMP fell below the calculated value at 570 V/cm, where dF reached its maximum of 57% at the cathodic and -55% at the anodic pole, over 600 mV, twice the FluoVolt value.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.4 Azimuthal membrane charging and polarization limits, paragraph 2; Figure 4Bfig4b-di8-maximum
    From the paper

    The measured IMP decreased below the calculated value when the electric field reached 570 V/cm, concurrently with reaching the maximum ΔF of 57 ± 14% at the cathodic pole and −55 ± 4% at the anodic pole

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Averaged over the first 10 of 60 pulses, Di-8-ANEPPS polarization at the cathodic pole reached 66% (710 mV).

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.4 Azimuthal membrane charging and polarization limits, paragraph 3; Figure 4B (dotted lines)fig4b-first-10-pulses
    From the paper

    Polarization measured this way reached 66 ± 15% (710 ± 200 mV) at the cathodic pole

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Above 780 V/cm the IMP at the poles falls progressively with field strength, more at the cathodic pole; at 1400 V/cm charging is undetectable at the cathodic pole and about -30% dF at the anodic pole.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.4 Azimuthal membrane charging and polarization limits, paragraph 4; Figure 4Bfig4b-cathodic-asymmetry
    From the paper

    As the electric field increased further, the IMP reached at the poles progressively decreased, and the reduction was more pronounced at the cathodic pole ... At 1400 V/cm, charging was no longer detectable at the cathodic pole

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Membrane regions near the equator are relatively unaffected and follow the cosine dependence of the Schwan equation up to 1000 V/cm.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.4 Azimuthal membrane charging and polarization limits, paragraph 4; Figure 4Cfig4c-equator-cosine
    From the paper

    Membrane areas closer to the equator (at polar angles closer to 0◦and 270◦) appeared relatively unaffected and followed the cosine dependence predicted by Schwan formula up to 1000 V/cm

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Shortening the pulse to 0.3 us at higher fields (357 to 3320 V/cm) did not raise the polarization limit; the maximum dF was 53% (about 600 mV) at both poles, as with 1-us pulses.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.4 Azimuthal membrane charging and polarization limits, paragraph 5; Figure 4Dfig4d-short-pulses-same-limit
    From the paper

    Contrary to the expectations, the results were similar to those with 1-μs pulses in Fig. 4B ... the maximum ΔF reached was 53 ± 4% (~600 mV) at both cell poles

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here. It also depends on fig4b-di8-maximum, blocked for the same reason.

  • Blocked

    1 mM Gd3+ extended anodic charging to -864 mV against -542 mV in parallel controls, and the measured IMP stayed close to the calculated IMP down to -780 mV.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.5 Membrane charging in the presence of Gd3+ ions, paragraph 1; Figure 5Afig5a-gd-extends-anodic
    From the paper

    Indeed, we found that 1 mM Gd3+ extended the range of membrane charging at the anodic pole down to −864 ± 44 mV (p < 0.001 compared to −542 ± 57 mV in parallel control experiments, Fig. 5A)

    Reported statistics
    • 2-tailed t-test, p < 0.001 (n = 7 cells with Gd3+ and 5 control cells)
    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    At the cathodic pole the IMP with Gd3+ reached 647 mV, not significantly higher than in controls, but Gd3+ prevented the decline of IMP with stronger fields.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.5 Membrane charging in the presence of Gd3+ ions, paragraph 2; Figure 5Afig5a-gd-cathodic-not-higher
    From the paper

    At the cathodic pole, polarization in the presence of Gd3+ reached 647 ± 44 mV, a value not significantly higher than that in the control group without Gd3+. However, Gd3+ prevented the progressive decline in IMP as the electric field was increased

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Gd3+ reduced the electroporation-induced effective membrane conductivity 2 to 3-fold for most datapoints.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.5 Membrane charging in the presence of Gd3+ ions, paragraph 4; Figure 5Cfig5c-gd-reduces-conductivity
    From the paper

    For most datapoints, Gd3+ reduced the electroporation- induced effective conductivity 2–3-fold

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here. It also needs the pole IMP of Fig. 5A; its dependency fig5b-conductivity-calibration was tested.

  • Blocked

    A 150 V/cm test pulse 5 us after a conditioning pulse still charges the membrane along a cosine after conditioning up to 1000 V/cm, while 1200 and 1400 V/cm conditioning markedly hinders charging at the poles.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.7 Fast restoration of membrane conductivity, paragraph 3; Figure 7Afig7a-test-pulse-cosine
    From the paper

    Polarization still followed a cosine function after conditioning PEFs of up to 1000 V/cm. However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here. It also depends on fig7b-test-pulse-recovery, blocked for the same reason.

  • Blocked

    During the conditioning pulse, pole dF falls 1.5 times below linear scaling at 560 V/cm, 2-fold at 760 V/cm and further at stronger fields.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.7 Fast restoration of membrane conductivity, paragraph 5; Figure 7B topfig7b-conditioning-sublinear
    From the paper

    Actual measurements fell 1.5 times below this line for 560 V/cm PEFs, 2- fold for 760 V/cm PEFs, and diverged further for more intense PEFs (p < 0.01 for all datapoints ≥560 V/cm, one sample t-test)

    Reported statistics
    • one sample t-test, p < 0.01 (n = 5 cells)
    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Six us after the conditioning pulse, test-pulse charging is unchanged after conditioning up to 760 V/cm, about 80% (not significant) after 1000 V/cm, and about 70% and 50% after 1200 and 1400 V/cm.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.7 Fast restoration of membrane conductivity, paragraph 5; Figure 7B bottomfig7b-test-pulse-recovery
    From the paper

    Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test)

    Reported statistics
    • 1200 V/cm conditioning: two-sided t-test, p < 0.05 (n = 5 cells)
    • 1400 V/cm conditioning: two-sided t-test, p < 0.01 (n = 5 cells)
    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here.

  • Blocked

    Effective membrane conductivity at the poles dropped about 10-fold (range 7 to 20) within 6 us after the electroporating pulse, with full resealing after 570 and 760 V/cm and residual conductivity after stronger pulses.

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only…

    Data missing from the datasetResults, 3.7 Fast restoration of membrane conductivity, paragraph 7; Figure 7Cfig7c-fast-resealing
    From the paper

    Fig. 7C shows a profound reduction in the λm,eff within just 6 μs after the electroporating pulse. For most datapoints, it dropped by a factor of 10 (range ... 7–20)

    Result

    The pulsed-laser potentiometric imaging (FluoVolt and Di-8-ANEPPS) is not in this dandiset, which holds only Fluo-4 time-lapses. The paper's Data availability says data are available on request. Six other dandisets of the same lab name this paper in their metadata (001515, 001516, 001517, 001518, 001525 and 001526) and by their titles hold the potentiometric experiments; they are targets of their own, and the claims file does not name them as data the paper relies on, so they were not used here. It also depends on fig7b-test-pulse-recovery, blocked for the same reason.

Attempt semenov-2026-06, on DANDI:001525 version 0.261006.1856

Reproducing Semenov et al. (2026) from dandiset 001525 5 Open in Colab

Reproduced2

  • Reproduced

    After a conditioning pulse of up to 1000 V/cm, polarization by the 150 V/cm test pulse 5 us later still follows a cosine of the angle to the field, while 1200 and 1400 V/cm conditioning pulses markedly reduce charging at the cell poles.

    After the first verification round the membrane trace was corrected.

    Results, 3.7, paragraph 3; Figure 7Arests on an assumptionfig7a-test-pulse-cosine-up-to-1000
    From the paper

    Polarization still followed a cosine function after conditioning PEFs of up to 1000 V/cm. However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles, indicating a persistent membrane permeabilization.

    Result

    After the first verification round the membrane trace was corrected. The overlays of the data check show that the first round's trace, the plain intensity peak along each ray, fell on bright dye inside cells c5 and c9 (a median 11.7 and 8.9 px inside the cell's outer edge); the trace used now is the intensity peak within 8 px inside the outer edge (2.5 to 4.8 px inside it in every cell). With it the outcome changes from partially reproduced to reproduced. Under the main reading (edge trace, six 5-us cells, annulus background, dark frames dropped), with the unpaired test of the amended criterion no pole reading differs from the 150/150 benchmark after 360 to 1000 V/cm conditioning (smallest p 0.059, mean of poles at 1000 V/cm), so the cosine part holds under reading (b). Pole dF is below the benchmark after 1200 and 1400 V/cm at the cathodic pole (unpaired p 0.022 and 0.0010) and for the mean of both poles (p 0.0013 and 0.0002); the anodic pole reaches p 0.086 at 1200 V/cm. Cosine amplitudes are 12.6% dF (benchmark), 10.4% (1000 V/cm) and 5.0% (1400 V/cm), R^2 0.73, 0.68 and -0.55 (A cos(theta - phi) without an offset term). Reading (a), the s.e. band, fails in every variant, and under the main reading at both poles at the control and at 1000 V/cm, because the profiles carry a uniform negative offset (-4.3% dF at the control); the baseline images fade by about 0.10% per frame in 43 of 44 files, which predicts -5.16% over all files against a measured -3.67% (r 0.18 over files), the sign of the bleaching the paper reports (Results 3.2) but not its size, so the offset's source is not established. With an offset term, a diagnostic outside the criterion, the fit lies within the s.e. at both poles up to 1000 V/cm and not at 1200 or 1400 V/cm. Over 22 variants the claim holds in 19; it fails in the 3 with the first round's peak trace, where the 1200 V/cm hindrance is not significant at any pole, so the 19 are not independent confirmations; the outcome turns on the edge trace. With the paired test, a variant, it holds in 21 of 22. The window of the edge trace (8 px) is a choice; with all six cells the claim holds under every window from 4 to 12 px (hindered at the cathodic pole and the mean of poles from 6 to 10 px, at every pole with 4 px, for the mean of poles only with 12 px). The trace of c5 dips into the cathodic pole arc in its 760 and 1000 V/cm files (8.8 and 8.2 px below its running median), strengths at which the cosine part holds; in c5's first file the notch lies 22 to 35 degrees from the cathodic pole. The outcome rests on the trace, the rank mapping of strengths and the single-pulse benchmark.

    Deviations from the paper’s method
    • The perimeter trace is found automatically, where the paper draws "the 6-pixel-wide trace ... along the cell perimeter" by hand in MetaMorph (Methods 2.3). The membrane at each angle is the intensity peak within 8 px inside the cell's outer edge (the steepest outward fall of intensity), an assumption adopted after the first round's plain intensity peak was seen to fall inside two cells; that trace is shown as a variant, and so are windows of 4, 6, 10 and 12 px.
    • The analysed cell is the largest object in each subject's field (an assumption; the paper says one cell per experiment, Fig. 2 legend, and does not say how it was chosen).
    • The field direction in image coordinates is not given by the dataset; it is the A-weighted circular mean of cosine-fit phases over all 5-us files (-75.6 degrees, per-file sd 6.8), and from the control files alone as a variant (-73.9 degrees). 0 degrees is the depolarized pole, as Fig. 7A plots it.
    • Conditioning strengths are mapped by rank from the files' generator volts (100 to 350 V) to the Fig. 7A labels 360 to 1400 V/cm, and the single 50 V pulse, recorded first in every cell, is taken as the 150/150 benchmark; an assumption, as the files give no field strengths and no 150/150 pair. Read as steps of 100 V from 0.15 kV/cm at 50 V, the strengths in the files' general description would put the levels 0 to 11% lower, with the same order.
    • Six 5-us cells are in the dataset where the paper reports n = 5; all six are used, and each five-cell subset is shown.
    • Background and dark frames are open in the paper. Main reading adopted as an assumption, background removed (median of an annulus 1.6 to 2.2 radii) and frames without a laser flash dropped; the paper's own scale (Fig. 7A about 13% dF at 150/150; 9.1% dF per 100 mV in Results 3.3, about 16% dF at 150 V/cm) is met only with a background removed (12.6 to 12.9% against 5.6%), and the files' camera floor is about 209 counts under a membrane trace of 451 to 692. All four combinations are shown.
    • The criterion's pole dF is tested under the pole readings of fig7b-test-pulse-unchanged-to-760 (cathodic, anodic, mean of both), with its test, the unpaired two-sample t-test against the control group (the paired test shown as a variant); reading (a) compares the fit at each pole with the s.e. of the pole mean over cells, for the legend's gray outline.
  • Reproduced

    Polarization by the test pulse 6 us after the conditioning pulse does not differ from the undamaged control for conditioning pulses up to 760 V/cm, and is at about 80% of control after 1000 V/cm, a difference that is not significant.

    The earlier run blocked this claim as methods_underspecified, because the criterion then required it when the…

    Results, 3.7, paragraph 5; Figure 7B, bottom panelrests on an assumptionquestion to the readerfig7b-test-pulse-unchanged-to-760
    From the paper

    measurements 6 μs later (test pulse) did not differ from the control up to 760 V/cm strength of the conditioning PEF; they were at ~80% of the control reading after 1000 V/cm conditioning PEF but the difference was not statistically significant

    Result

    The earlier run blocked this claim as methods_underspecified, because the criterion then required it when the paired and unpaired tests disagree, and they did. The reader's answer (questions/001525.yaml) amended the criterion to take the unpaired two-sample t-test against the control group as the paper's test, with the paired and one-sample tests as variants, and dropped that rule. After the first verification round the membrane trace was corrected (see fig7a-test-pulse-cosine-up-to-1000); the outcome stays reproduced. Under the main reading the unpaired t-test finds no difference from control at 360 to 1000 V/cm at either pole (smallest p 0.098, anodic at 760 V/cm; cathodic p 0.21 to 0.99). The absence holds in 19 of 22 variants; in the other 3 the anodic pole differs at 760 V/cm (p 0.027 to 0.046). At 1000 V/cm the test response is 79.7% of control at the anodic pole, within 80 +- 8, the measured value recorded as the only pole reading that matches; it is 57.5% at the cathodic pole and 71.9% for their mean, outside the tolerance (unpaired p 0.21 and 0.24). In all 22 variants at least one pole reading is within tolerance. Unpaired effect sizes up to 1000 V/cm run from d = -1.05 to +0.15. The paired test, a variant, finds no difference at either pole under the main reading (smallest p 0.098) and in 18 of 22 variants; the one-sample test in 21 of 22. For the mean of both poles, which the criterion does not test for absence, the paired test gives p 0.018 at 760 V/cm and 0.016 at 1000 V/cm (unpaired 0.14 and 0.059). The trace window changes the outcome; the absence holds with windows of 6 to 12 px and fails with 4 px (anodic pole at 760 V/cm, p 0.028), and without c5 it fails under every window (anodic 760 V/cm, p 0.010 to 0.046). The trace of c5 dips into the cathodic pole arc in its 760 and 1000 V/cm files, where its cathodic dF is -3.3% and -1.9%; these values pull the cathodic pole towards a difference, and none is found (unpaired p 0.74 and 0.21). With the first round's trace the cathodic pole was at 133% of control after 360 V/cm (paired p 0.0038); with the edge trace it is at 99.5%. The outcome rests on the trace and its window, the rank mapping of strengths and the single-pulse benchmark, assumptions shared with fig7a-test-pulse-cosine-up-to-1000.

    Deviations from the paper’s method
    • Same trace, cell, field direction, strength mapping, benchmark, cell count and main reading as fig7a-test-pulse-cosine-up-to-1000.

Partially reproduced3

  • Partially reproduced

    Conditioning pulses of 1200 and 1400 V/cm reduce charging by the test pulse 6 us later to about 70% and 50% of control (p < 0.05 and p < 0.01).

    After the first verification round the membrane trace was corrected (see fig7a-test-pulse-cosine-up-to-1000)…

    Results, 3.7, paragraph 5; Figure 7B, bottom panelrests on an assumptionquestion to the readerfig7b-test-pulse-reduced-1200-1400
    From the paper

    Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test)

    Reported statistics
    • 1200 V/cm conditioning against control: two-sided t-test, p < 0.05 (n = 5 cells)
    • 1400 V/cm conditioning against control: two-sided t-test, p < 0.01 (n = 5 cells)
    Result

    After the first verification round the membrane trace was corrected (see fig7a-test-pulse-cosine-up-to-1000), and the outcome changes from not reproduced to partially reproduced. Measured values are the cathodic pole, the first pole reading the criterion lists. Under the main reading both reductions reach the paper's significance levels at the cathodic pole (25.2% and -11.3% of control after 1200 and 1400 V/cm, unpaired p 0.022 and 0.0010) and for the mean of both poles (53.4% and 27.2%, p 0.0013 and 0.0002), with values outside 70 +- 7 and 50 +- 5, which the criterion calls partial. The anodic pole has values within tolerance (68.7% and 48.0%) but p 0.086 and 0.011, short of p < 0.05 and p < 0.01. No pole reading meets the whole criterion in any of 22 variants; both significance levels are reached in 19; in the 3 with the first round's peak trace no pole reading reaches both (not reproduced, the first round's outcome). The paired variant meets the whole criterion in none. Effect sizes at 1400 V/cm are -10.5% dF at the cathodic pole (unpaired d -2.66) and -9.1% dF at the anodic (d -1.80). The partial outcome comes from the cathodic and mean readings only. The round-2 verifier pointed out that Results 3.7 paragraph 6 omits a negative cathodic dF at 1400 V/cm; if that is the test-pulse value, the paper's ~50% can only be an anodic value. Under the anodic reading alone the values are within tolerance in 12 of 22 variants, both significance levels are reached in 2 and the whole criterion in none; under the main reading (p 0.086 and 0.011) the claim would be not reproduced. This is asked of a reader (questions/001525.yaml), and the outcome is judged on the criterion as written. The cathodic value after 1400 V/cm (-11.3%) is negative, as the omitted value is; after 1200 V/cm (25.2%) it lies well below the paper's 70%. Under every trace window from 4 to 12 px both significance levels are reached with values outside tolerance and the whole criterion is met under no pole reading; the anodic values stay within tolerance (67.3 to 69.2% and 43.6 to 48.3%) with p 0.035 to 0.092 at 1200 V/cm.

    Deviations from the paper’s method
    • Same trace, cell, field direction, strength mapping, benchmark, cell count and main reading as fig7a-test-pulse-cosine-up-to-1000.
  • Partially reproduced

    Under Eq. (2), effective membrane conductivity barely affects charging while it stays far below cytosol and medium conductivity; a 10-fold increase reduces IMP by about 2% and a 100-fold increase by 12%.

    Eq. (2) with the Methods' parameters gives f = 1.498 for the intact membrane, an IMP reduction (1 - f/1.5) of…

    Results, 3.5, paragraph 3; Figure 5Bfig5b-conductivity-calibration
    From the paper

    its 10-fold increase would go unnoticed, yielding just a ~2% IMP reduction, and a 100-fold increase would reduce IMP by just 12%

    Result

    Eq. (2) with the Methods' parameters gives f = 1.498 for the intact membrane, an IMP reduction (1 - f/1.5) of 11.87% for a 100-fold rise in membrane conductivity, within 12 +- 1.2, and 1.33% for a 10-fold rise, outside 2 +- 0.5 (1.20% relative to the intact f). With R from 6 to 10 um the 10-fold value stays between 1.00% and 1.65%. The equation in the PDF's text layer (page 3) has the form the claims file read; the rendered page could not be viewed (no PDF renderer in this run either). The "~2%" may have been read from the Fig. 5B graph.

  • Partially reproduced

    After mildly electroporating pulses (570 and 760 V/cm) the membrane reseals fully within 6 us, while after stronger pulses increased conductivity persists for at least 6 us; the cathodic pole is more conductive than the anodic during the pulse, but the test pulse finds no difference between the poles.

    The first round blocked this claim for its dependence on fig7c-conductivity-drops-10-fold.

    Results, 3.7, paragraph 7; Figure 7Cverifier disagreed at firstrests on an assumptionquestion to the readerfig7c-full-reseal-mild-residual-strong
    From the paper

    While the cathodic pole became more conductive than the anodic pole during the electroporating pulse (Fig. 7B, see also Figs. 1 and 4B–D), no difference between the poles was detected by the test pulse. For mildly electroporating PEFs of 570 and 760 V/cm, membrane resealed fully (within the accuracy of measurements) within just 6 μs. With more intense PEFs, the residual increased conductivity persisted for at least 6 μs

    Result

    The first round blocked this claim for its dependence on fig7c-conductivity-drops-10-fold. The verifier pointed out that its reseal and residual parts need only test-pulse data, which the dataset holds, and that the criterion counts those two parts as a partial reproduction; it is now tested. What it takes from fig7c-conductivity-drops-10-fold is the conversion of the test ratio to lm,eff, which needs no conditioning-pulse image; only the part "the cathodic pole is more conductive during the pulse" needs those images, which are not in the dataset, so that part is not tested and the claim can be at most partially reproduced. Under the main reading, full reseal holds; after 570 and 760 V/cm the test response does not differ from control at either pole (unpaired p 0.81 and 0.74 cathodic, 0.64 and 0.098 anodic), though the anodic pole is at 71.2% of control after 760 V/cm. The residual holds; the test response is below 100% of control after 1000, 1200 and 1400 V/cm at both poles (cathodic 57.5%, 25.2%, -11.3%; anodic 79.7%, 68.7%, 48.0%), a test lm,eff of 0.17 and 0.66 mS/m and no finite value at the cathodic pole and 0.057, 0.10 and 0.24 mS/m at the anodic, against 3e-4 mS/m intact. Both hold in 19 of 22 variants; the 3 others are those in which the anodic pole differs from control at 760 V/cm. The part "the test pulse finds no difference between the poles" fails; after 1400 V/cm the cathodic minus anodic normalized test dF is -59.3 points of control (paired p 0.0002; unpaired 0.0015; normalized per cell 0.0056), where the cathodic pole no longer charges; it holds only in the 6 variants that keep the dark frames. Fig. 7C, to which the paper's sentence refers, leaves out the negative cathodic point at 1400 V/cm; with 1400 V/cm left out, a variant, the paired test finds no pole difference at 360 to 1200 V/cm (smallest p 0.12), in 21 of 22 variants. The criterion tests 1400 V/cm; this is asked of a reader (questions/001525.yaml) and does not change the outcome. With trace windows of 6 to 12 px reseal and residual hold; with 4 px they fail (the anodic pole differs at 760 V/cm, p 0.028), and the pole difference at 1400 V/cm is found under every window (paired p 0.0002 to 0.0014). The significance of fig7b-test-pulse-reduced-1200-1400 is reported there (1000 V/cm not significant, as the paper says).

    Deviations from the paper’s method
    • Same trace, cell, field direction, strength mapping, benchmark, cell count and main reading as fig7a-test-pulse-cosine-up-to-1000.
    • Normalized test dF for the pole comparison is per-cell dF over the group control of each pole; normalization by each cell's own control is shown as a variant. A standard choice the criterion leaves open; it does not change the result at 1400 V/cm.

Not tested in a notebook 22

22 data missing from the dataset

Blocked22

  • Blocked

    During the electroporating pulse, pole polarization falls below the linear scaling expected for an undamaged membrane, 1.5-fold below at 560 V/cm and 2-fold at 760 V/cm and further at stronger fields, significantly for every strength of 560 V/cm or more.

    The top panel of Fig. 7B comes from the single-pulse escalation of Fig. 4B (Results 3.7, "Data for the top…

    Data missing from the datasetResults, 3.7, paragraph 5; Figure 7B, top panelfig7b-conditioning-pulse-below-linear
    From the paper

    Actual measurements fell 1.5 times below this line for 560 V/cm PEFs ... and diverged further for more intense PEFs (p < 0.01 for all datapoints ≥560 V/cm, one sample t-test)

    Reported statistics
    • one sample t-test, p < 0.01 (n = 5 cells)
    Result

    The top panel of Fig. 7B comes from the single-pulse escalation of Fig. 4B (Results 3.7, "Data for the top panel of Fig. 7B were extracted from dF measurements in Fig. 4B"). The dataset holds one image per pulse pair, at 900 ns into the test pulse, and single pulses only at 50 V (150 V/cm); no image of a conditioning pulse at 360 to 1400 V/cm is in it. The files' general description mentions single pulses from 0.15 to 1.57 kV/cm, which are not in this dandiset.

  • Blocked

    Effective membrane conductivity at the poles falls by about 10-fold (range 7 to 20) within 6 us after the electroporating pulse, for most datapoints.

    Depends on fig7b-conditioning-pulse-below-linear, whose conditioning-pulse images are not in the dataset.

    Data missing from the datasetResults, 3.7, paragraphs 6 and 7; Figure 7Cfig7c-conductivity-drops-10-fold
    From the paper

    Fig. 7C shows a profound reduction in the λm,eff within just 6 μs after the electroporating pulse. For most datapoints, it dropped by a factor of 10 (range: 7–20).

    Result

    Depends on fig7b-conditioning-pulse-below-linear, whose conditioning-pulse images are not in the dataset. The test-pulse half (lm,eff from the test dF) could be computed from the dataset but the fold drop needs both.

  • Blocked

    With 1-us pulses, polarization grows with field strength up to 570 to 780 V/cm; at stronger fields the poles become leaky and show reduced or absent polarization, while regions closer to the equator remain polarized and may exceed the poles.

    Judged on the single-pulse Di-8-ANEPPS escalation of Fig. 4B-C (43 to 1400 V/cm), not in the dataset, which…

    Data missing from the datasetFigure 1 legend; Results, 3.1, paragraph 1fig1-poles-leaky-equator-intact
    From the paper

    Still stronger electric fields produce a distinct pattern of reduced or absent polarization at the poles (where the membrane becomes too leaky to accumulate the charge) while regions closer to the equator remain relatively intact and may polarize more than the poles

    Result

    Judged on the single-pulse Di-8-ANEPPS escalation of Fig. 4B-C (43 to 1400 V/cm), not in the dataset, which holds only the two-pulse experiment of Fig. 7.

  • Blocked

    FluoVolt dF rises in proportion to field strength until apparent saturation at 66% (255 mV) at 360 V/cm at the cathodic pole and -83% (-320 mV) at 570 V/cm at the anodic pole; stronger fields do not raise it further and lower it at the cathodic pole.

    No FluoVolt recording is in the dataset; every file is Di-8-ANEPPS.

    Data missing from the datasetResults, 3.2, paragraph 2; Figure 2Afig2a-fluovolt-saturation
    From the paper

    ΔF increased proportionally to the electric field strength until reaching apparent saturation at 66% ΔF (255 mV IMP) at 360 V/cm at the cathodic pole, and −83% ΔF (−320 mV IMP) at 570 V/cm at the anodic pole

    Result

    No FluoVolt recording is in the dataset; every file is Di-8-ANEPPS. Dandiset 001526, which names the same paper and is a separate target of the registry, was not used.

  • Blocked

    FluoVolt baseline fluorescence is stable without pulses (no significant bleaching), and the response stays stable through the 60 pulses of each set even at strongly electroporating fields of 1000 V/cm and above.

    No FluoVolt recording is in the dataset (see fig2a-fluovolt-saturation).

    Data missing from the datasetResults, 3.2, paragraph 2; Figure 2Afig2a-fluovolt-stable-within-set
    From the paper

    Field strengths of 1000 V/cm and higher caused strong electroporation (see Section 3.5), but the dye response in each set stayed stable through the 60 pulses applied

    Result

    No FluoVolt recording is in the dataset (see fig2a-fluovolt-saturation).

  • Blocked

    Di-8-ANEPPS dF keeps rising up to 570 V/cm at both poles, and responses at 780 V/cm and above decrease gradually within each set of 60 pulses.

    The single-pulse Di-8-ANEPPS escalation (43 to 1400 V/cm, n = 5) is not in the dataset.

    Data missing from the datasetResults, 3.2, paragraph 3; Figure 2Bfig2b-di8-climbs-then-declines-in-set
    From the paper

    ΔF kept climbing up to the electric field strength of 570 V/cm at both cell poles ... responses to PEFs at and above 780 V/cm decreased gradually in each set of 60 images

    Result

    The single-pulse Di-8-ANEPPS escalation (43 to 1400 V/cm, n = 5) is not in the dataset.

  • Blocked

    Repeated alternating sets of 150 and 230 V/cm pulses give dF responses that stay constant within and between sets, up to 800 flashes and 480 pulses before the 1000 V/cm exposure.

    The alternating 150 and 230 V/cm sets of Fig. 2C-D are not in this dataset.

    Data missing from the datasetResults, 3.2, paragraph 4; Figure 2C and 2Dfig2cd-stable-at-150-230
    From the paper

    Repeated sets of PEFs at 150 and 230 V/cm, delivered in alternation, produced ΔF responses that stayed constant both within each set and between the sets

    Result

    The alternating 150 and 230 V/cm sets of Fig. 2C-D are not in this dataset. Dandiset 001526, titled as the post-electroporation suitability experiment of the same paper, may hold them; it is a separate target and was not used here.

  • Blocked

    At 1000 V/cm, dF at the cathodic pole declines from 40 +- 10% at the start of the set to 26.6 +- 8% at its end, a trend that is not significant.

    The Fig. 2C experiment is not in this dataset (see fig2cd-stable-at-150-230).

    Data missing from the datasetResults, 3.2, paragraph 4; Figure 2Cfig2c-within-set-decline-1000
    From the paper

    at an electroporating field strength of 1000 V/cm, ΔF at the cathodic pole decreased from 40 ± 10% at the beginning of the set to 26.6 ± 8% at the end of it. Although not statistically significant (p > 0.05)

    Reported statistics
    • not named (Methods name Student's t-test), p > 0.05 (n = 8 cells)
    Result

    The Fig. 2C experiment is not in this dataset (see fig2cd-stable-at-150-230).

  • Blocked

    dF averaged over each set stays nearly constant before electroporation but drops by about 20% in the sets acquired after the 1000 V/cm exposure (p < 0.05).

    The Fig. 2C-D experiment is not in this dataset (see fig2cd-stable-at-150-230).

    Data missing from the datasetResults, 3.2, paragraph 4; Figure 2Dfig2d-lasting-drop-after-1000
    From the paper

    ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05)

    Reported statistics
    • 2-tailed paired t-test, p < 0.05 (n = 8 cells)
    Result

    The Fig. 2C-D experiment is not in this dataset (see fig2cd-stable-at-150-230).

  • Blocked

    Fit through the origin over -150 to +150 mV of calculated IMP, FluoVolt dF changes by 26% and Di-8-ANEPPS by 9.1% per 100 mV, with correlation coefficients 0.96 and 0.78.

    Needs single-pulse recordings with both dyes at 43 to 360 V/cm; none are in the dataset (no FluoVolt file, and…

    Data missing from the datasetResults, 3.3; Figure 3uses data from outside the datasetfig3-dye-calibration-slopes
    From the paper

    The correlation coefficients of the fits equaled 0.96 for FluoVolt and 0.78 for Di-8 ANEPPS (due to a lower signal-to-noise ratio), with respective slope coefficients of 26% and 9.1% ΔF per 100 mV of IMP

    Result

    Needs single-pulse recordings with both dyes at 43 to 360 V/cm; none are in the dataset (no FluoVolt file, and Di-8-ANEPPS single pulses only at 50 V). The outside tau fit was not needed.

  • Blocked

    FluoVolt departs from linearity already at +-200 mV of calculated IMP, while Di-8-ANEPPS stays essentially linear from -500 to +500 mV, so the early FluoVolt departure reflects the dye's range and not electroporation.

    Depends on fig3-dye-calibration-slopes; the recordings are not in the dataset.

    Data missing from the datasetResults, 3.3; Figure 3uses data from outside the datasetfig3-fluovolt-nonlinear-di8-linear
    From the paper

    The actual measurements with FluoVolt gradually became non-linear already at ±200 mV, while those for Di-8-ANEPPS stayed essentially linear throughout the tested range from −500 to +500 mV

    Result

    Depends on fig3-dye-calibration-slopes; the recordings are not in the dataset.

  • Blocked

    With FluoVolt, measured and calculated IMP match only at 43 and 150 V/cm; stronger pulses give a maximum dF of 71 +- 10% at the cathodic and -83.5 +- 5% at the anodic pole, and cathodic polarization falls from 71% at 360 V/cm to 45 to 50% at 1000 to 1400 V/cm.

    No FluoVolt recording is in the dataset.

    Data missing from the datasetResults, 3.4, paragraph 1; Figure 4Auses data from outside the datasetfig4a-fluovolt-limit
    From the paper

    this assumption held only for the applied fields of 43 and 150 V/cm, where measured and calculated IMP matched. With stronger PEFs, maximum ΔF reached 71 ± 10% and −83.5 ± 5% at the cathodic and anodic poles, respectively ... polarization at the cathodic pole decreased from 71% at 360 V/cm to 45–50% at 1000–1400 V/cm

    Result

    No FluoVolt recording is in the dataset.

  • Blocked

    With Di-8-ANEPPS, measured IMP falls below the calculated value when the field reaches 570 V/cm, as dF reaches its maximum of 57 +- 14% at the cathodic and -55 +- 4% at the anodic pole, over 600 mV, twice the FluoVolt value.

    The single-pulse Di-8-ANEPPS escalation of Fig. 4B is not in the dataset.

    Data missing from the datasetResults, 3.4, paragraph 2; Figure 4Buses data from outside the datasetfig4b-di8-threshold-570
    From the paper

    The measured IMP decreased below the calculated value when the electric field reached 570 V/cm, concurrently with reaching the maximum ΔF of 57 ± 14% at the cathodic pole and −55 ± 4% at the anodic pole. These values corresponded to membrane polarization by over 600 mV

    Result

    The single-pulse Di-8-ANEPPS escalation of Fig. 4B is not in the dataset.

  • Blocked

    Averaged over the first 10 of the 60 pulses, cathodic polarization reaches 66 +- 15% (710 +- 200 mV), so the 600-mV maximum over 60 pulses is not the dye limit.

    The Fig. 4B experiment is not in the dataset.

    Data missing from the datasetResults, 3.4, paragraph 3; Figure 4B, dotted linesuses data from outside the datasetfig4b-first-10-pulses
    From the paper

    Polarization measured this way reached 66 ± 15% (710 ± 200 mV) at the cathodic pole

    Result

    The Fig. 4B experiment is not in the dataset.

  • Blocked

    Above the threshold, pole IMP falls progressively as the field rises, more at the cathodic pole; at 1400 V/cm charging is no longer detectable at the cathodic pole and is about 30% dF (about -330 mV) at the anodic pole.

    The Fig. 4B experiment is not in the dataset.

    Data missing from the datasetResults, 3.4, paragraph 4; Figure 4Buses data from outside the datasetfig4b-cathodic-pole-more-damaged
    From the paper

    As the electric field increased further, the IMP reached at the poles progressively decreased, and the reduction was more pronounced at the cathodic pole ... At 1400 V/cm, charging was no longer detectable at the cathodic pole (i.e., the membrane became fully permeable) and dropped to ~30% ΔF (~ −330 mV) at the anodic pole

    Result

    The Fig. 4B experiment is not in the dataset.

  • Blocked

    Membrane regions near the equator remain unaffected and follow the cosine dependence predicted by the Schwan equation up to 1000 V/cm, even when the poles are electroporated.

    The Fig. 4B-C experiment is not in the dataset.

    Data missing from the datasetResults, 3.4, paragraph 4; Figure 4Cuses data from outside the datasetfig4c-equator-follows-cosine
    From the paper

    appeared relatively unaffected and followed the cosine dependence predicted by Schwan formula up to 1000 V/cm

    Result

    The Fig. 4B-C experiment is not in the dataset.

  • Blocked

    With 0.3-us pulses of 357 to 3320 V/cm imaged at 275 ns, the maximum dF is 53 +- 4% (about 600 mV) at both poles, and the dependence on field strength is like that with 1-us pulses.

    No 0.3-us pulse recording is in the dataset; every file states 1-us pulses.

    Data missing from the datasetResults, 3.4, paragraph 5; Figure 4Duses data from outside the datasetfig4d-short-pulses-same-limit
    From the paper

    the maximum ΔF reached was 53 ± 4% (~600 mV) at both cell poles. The pattern of how the response changed with increasing PEF strength was not different from that with 1-μs PEFs either

    Result

    No 0.3-us pulse recording is in the dataset; every file states 1-us pulses.

  • Blocked

    1 mM Gd3+ extends anodic charging to -864 +- 44 mV against -542 +- 57 mV in controls (p < 0.001), and measured IMP stays nearly equal to calculated IMP down to -780 mV, so the dye response is linear at high IMPs.

    No recording with Gd3+ is in the dataset, and the control group of Fig. 5A (single pulses 150 to 1400 V/cm) is…

    Data missing from the datasetResults, 3.5, paragraph 1; Figure 5Auses data from outside the datasetfig5a-gd-extends-anodic-charging
    From the paper

    1 mM Gd3+ extended the range of membrane charging at the anodic pole down to −864 ± 44 mV (p < 0.001 compared to −542 ± 57 mV in parallel control experiments, Fig. 5A). Furthermore, measured IMP remained nearly identical to the theoretical IMPC down to −780 mV

    Reported statistics
    • 2-tailed t-test, p < 0.001 (n = 7 cells with Gd3+ and 5 control cells)
    Result

    No recording with Gd3+ is in the dataset, and the control group of Fig. 5A (single pulses 150 to 1400 V/cm) is not either.

  • Blocked

    At the cathodic pole Gd3+ cells reach 647 +- 44 mV, not significantly more than controls, but Gd3+ prevents the progressive decline of IMP with stronger fields.

    As fig5a-gd-extends-anodic-charging.

    Data missing from the datasetResults, 3.5, paragraph 2; Figure 5Auses data from outside the datasetfig5a-gd-cathodic-no-higher-but-no-decline
    From the paper

    At the cathodic pole, polarization in the presence of Gd3+ reached 647 ± 44 mV, a value not significantly higher than that in the control group without Gd3+. However, Gd3+ prevented the progressive decline in IMP as the electric field was increased.

    Reported statistics
    • Gd3+ against control, datapoints below -700 mV and above 1200 mV of IMPC: 2-tailed t-test, p < 0.05 (n = 7 cells with Gd3+ and 5 control cells)
    Result

    As fig5a-gd-extends-anodic-charging.

  • Blocked

    For most datapoints, Gd3+ reduces the electroporation-induced effective membrane conductivity 2- to 3-fold.

    Needs the Fig. 5A recordings, which are not in the dataset.

    Data missing from the datasetResults, 3.5, paragraph 4; Figure 5Cuses data from outside the datasetfig5c-gd-reduces-conductivity
    From the paper

    For most datapoints, Gd3+ reduced the electroporation ... induced effective conductivity 2–3-fold

    Result

    Needs the Fig. 5A recordings, which are not in the dataset.

  • Blocked

    A single 1-us pulse causes clear Ca2+ entry at 1000 and 1200 V/cm, with the signal elevated through the 5-min observation; the small rise after 780 V/cm is not significant.

    No Fluo-4 calcium imaging is in the dataset.

    Data missing from the datasetResults, 3.6, paragraph 2; Figure 6Afig6a-ca-single-pulse
    From the paper

    established a clear peak of Ca2+ entry at 1000 and 1200 ... and Ca2+ signal remained elevated through the 5-min observation period (Fig. 6A). A subtle ΔF increase after exposure at 780 V/cm was at the detection limit and not statistically significant.

    Result

    No Fluo-4 calcium imaging is in the dataset.

  • Blocked

    With trains of 60 1-us pulses at 6 Hz, a strong Ca2+ response occurs in 28% of cells at 780 V/cm and nearly all cells at higher strengths; at 650 V/cm only 2 cells (5.9%) respond strongly, but the mean signal at the end is above zero (p < 0.001) and above that at 230 V/cm (p < 0.05, one-tailed).

    No Fluo-4 calcium imaging is in the dataset.

    Data missing from the datasetResults, 3.6, paragraph 3; Figure 6Bfig6b-ca-train-thresholds
    From the paper

    A strong Ca2+ response was recorded in 28% of cells exposed at 780 V/cm and in nearly all cells at higher intensities (Fig. 6B). At 650 V/cm, only 2 cells (5.9%) showed a strong response, but the mean Ca2+ signal by the end of recording was significantly different from zero (p < 0.001, one sample t-test) and marginally higher than after exposure at 230 V/cm (p < 0.05, single-tailed t-test)

    Reported statistics
    • 650 V/cm end-of-recording signal against zero: one sample t-test, p < 0.001
    • 650 V/cm against 230 V/cm: single-tailed t-test, p < 0.05
    Result

    No Fluo-4 calcium imaging is in the dataset.

Attempt semenov-2026-07, on DANDI:001526 version 0.261006.1851

Reproducing Semenov et al. (2026) from dandiset 001526 5 Open in Colab

Reproduced1

  • Reproduced

    At 1000 V/cm, cathodic pole dF fell from 40 +- 10% at the start of the set to 26.6 +- 8% at its end, a trend that was not statistically significant.

    Background recording subtracted, reading (b) (PEF images 1 to 10 and 51 to 60), 31.7 +- 4.4% to 21.0 +- 5.2%…

    Results, section 3.2, paragraph 4; Figure 2Crests on an assumptionfig2c-1000-within-set
    From the paper

    In contrast, at an electroporating field strength of 1000 V/cm, ΔF at the cathodic pole decreased from 40 ± 10% at the beginning of the set to 26.6 ± 8% at the end of it. Although not statistically significant (p > 0.05)

    Reported statistics
    • 2-tailed paired t-test (the test named in the Fig. 2 legend), p > 0.05 (n = 8 cells)
    Result

    Background recording subtracted, reading (b) (PEF images 1 to 10 and 51 to 60), 31.7 +- 4.4% to 21.0 +- 5.2%, n = 11, paired t-test p = 0.094, end lower in 8 of 11 cells; this is the reading that matches and is given as measured. Readings (a) 40.7 to 22.4% (p = 0.008) and (c) 35.4 to 23.4% (p = 0.006) have values within tolerance but p below 0.05. Annulus, reading (b), 33.5 to 21.5% with p = 0.035, so no window meets the criterion under the annulus; without subtraction (13.3 and 8.5%) and with the darkest-pixel floor (24.0 and 15.7%) the start is outside the tolerance. With F0 from images 2 to 40 the start under (b) is 28.5%, just outside. Among the 165 choices of 8 of the 11 cells the criterion is met in 91 (background recording), 100 (annulus) and none without subtraction or with the floor. With per-cell pole angles it is met under the background recording (p = 0.080), not under the annulus (p = 0.028). In round 1 (annulus, c4 traced on internal staining) the match was 31.9 to 21.0% with p = 0.051. The match rests on the background reading, and the background recording was adopted after the annulus reading had stopped meeting this claim, so it rests on a choice made after the results. If the darkest pixels are the camera offset (floor reading), the claim is not met.

    Deviations from the paper’s method
    • Background subtraction is an assumption. Section 2.3 describes dF = 100 (F - F0)/F0 with no background step, section 2.4 subtracts the background fluorescence of a cell-free region for Fluo-4, and the claims file names both readings. The adopted reading subtracts, for 2025-05-01, the mean of the cell-free background recording made with each cell (the files call it a recording in the background region without cells, so the experimenters recorded it with every cell of that session), point by point along the trace; for 2025-05-06, which has no background recordings, the per-image median of a cell-free annulus 2 to 3 radii from the cell, whose level the background recordings of the first session match within 0.97 to 1.08 times. Cell-free background is 52 to 54% of the trace intensity, and 65 to 66 counts above the darkest pixels (no dark frame or camera offset is given), and the paper's own values at 1000 V/cm (40 and 26.6%) are on the scale of the subtracted readings and about 3 times the unsubtracted ones (40/13.3 = 3.0 and 26.6/8.5 = 3.1 under window (b)). The notebook shows every reading (background recording, annulus, darkest-pixel floor, none). Round 1 adopted the annulus for both sessions; the background recording was adopted in the revision after round 1, after the results under both readings had been seen, and in that revision the annulus reading stopped meeting fig2c-1000-within-set while the background recording met it. The choice is to be read as made after the results.
    • The analysed cell is the one nearest the image centre of the cell's sham recording (an assumption; the files do not say which of the one to eight cells found in each field was analysed, and section 2.2 centres the field of view between the electrodes). The notebook draws every traced membrane on its baseline image.
    • The 6-pixel-wide perimeter trace is found automatically as the outer ridge of the membrane staining in the sham recording's baseline image and moved by the measured drift (at most 2 pixels), where the paper draws it by hand in MetaMorph (section 2.3); the 360 points are spaced by 1 degree of angle, not by equal arc length. For 2025-05-01 c4 the default rule (steepest outward fall) put the trace on internal staining (median radius 21.2 px), so that cell is traced with the outermost strong fall (34.1 px); the other cells keep the default rule, which the overlays show on the membrane (c3's trace cuts inside the cell on one side, away from the poles).
    • The cathodic pole angle is the median over the session's cells of the phase of a cosine fitted to the polarization profile at non-electroporating fields (83.0 degrees for 1 us, 82.1 degrees for 0.3 us, close to straight up, as in Fig. 1); the paper places the poles by the field direction. Per-cell phases (73.1 to 93.6 degrees) are shown as a variant.
    • Field strengths are the paper's labels (Fig. 2C; the Fig. 4D axis labels 357, 760, 1000, 1200, 1420, 1630, 2050, 2473 and 3320 V/cm, read from the figure on page 6 of the PDF) matched by order to the pulse amplitudes in volts that the files give; the labels are not proportional to the volts.
    • 11 cells are used where the paper reports n = 8; the dataset does not say which 8. Four cells depart from the described order of sets (c3 and c4 before the 1000 V/cm exposure, c1 and c11 after); sets are matched by their rank at each field. The notebook applies the criteria without c4, without c3 and c4, without all four, and to every choice of 8 of the 11 cells.

Partially reproduced2

  • Partially reproduced

    Set-averaged dF stayed nearly constant before electroporation but dropped by about 20% (a small but persistent reduction of at most 20%) in the 150 and 230 V/cm sets acquired after the 1000 V/cm exposure.

    Measured is the mean reduction over the four post-exposure sets of both poles' |dF| averaged (readings b and…

    Results, section 3.2, paragraph 4; Figure 2D and legendrests on an assumptionquestion to the readerfig2d-lasting-reduction
    From the paper

    ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05).

    Reported statistics
    • 2-tailed paired t-test, p < 0.05 (n = 8 cells)
    Result

    Measured is the mean reduction over the four post-exposure sets of both poles' |dF| averaged (readings b and i), background recording subtracted. Per set 30.3, 28.8, 26.1 and 23.8% (p = 0.017, 0.018, 0.019, 0.094). Under every background and F0 reading the both-pole mean is 26.9 to 28.1% and no set with p < 0.05 has a reduction within 18 to 22%. At single poles the drop is at the cathodic pole for 150 V/cm (49.5 and 43.1%, p = 0.017 and 0.026) and at the anodic pole for 230 V/cm (32.4 and 33.3%, p = 0.051 and 0.109). The only per-pole mean within 18 to 22% is the anodic pole with F0 from images 2 to 40 and the annulus (18.7%), an average of set reductions of 2.3 to 30.4% that comes with a pre-exposure set at p = 0.029, so it does not meet the reproduced clause, and the partial clause (size outside the tolerance under every reading) is not literally met there either; partial is the closer description, as every both-pole set size is outside the tolerance with the session pole angle; the round-1 pass of this kind (annulus, anodic, 18.0%) is gone with c4 re-traced (17.4%). The criterion's condition that no pre-exposure set differs fails under the adopted reading (p = 0.031) and holds without subtraction. The reduction is significant under every reading and larger than about 20%, the partial case the criterion names. Without c3 and c4 the criterion is met under the background recording, annulus and no-subtraction readings; among the 165 choices of 8 cells it is met in 2 (background recording), and in 16 more the size is met with a pre-exposure set that differs, which meets neither clause; without all four protocol-breaking cells (n = 7) no post-exposure set reaches p < 0.05.

    Deviations from the paper’s method
    • Background subtraction is an assumption. Section 2.3 describes dF = 100 (F - F0)/F0 with no background step, section 2.4 subtracts the background fluorescence of a cell-free region for Fluo-4, and the claims file names both readings. The adopted reading subtracts, for 2025-05-01, the mean of the cell-free background recording made with each cell (the files call it a recording in the background region without cells, so the experimenters recorded it with every cell of that session), point by point along the trace; for 2025-05-06, which has no background recordings, the per-image median of a cell-free annulus 2 to 3 radii from the cell, whose level the background recordings of the first session match within 0.97 to 1.08 times. Cell-free background is 52 to 54% of the trace intensity, and 65 to 66 counts above the darkest pixels (no dark frame or camera offset is given), and the paper's own values at 1000 V/cm (40 and 26.6%) are on the scale of the subtracted readings and about 3 times the unsubtracted ones (40/13.3 = 3.0 and 26.6/8.5 = 3.1 under window (b)). The notebook shows every reading (background recording, annulus, darkest-pixel floor, none). Round 1 adopted the annulus for both sessions; the background recording was adopted in the revision after round 1, after the results under both readings had been seen, and in that revision the annulus reading stopped meeting fig2c-1000-within-set while the background recording met it. The choice is to be read as made after the results.
    • The analysed cell is the one nearest the image centre of the cell's sham recording (an assumption; the files do not say which of the one to eight cells found in each field was analysed, and section 2.2 centres the field of view between the electrodes). The notebook draws every traced membrane on its baseline image.
    • The 6-pixel-wide perimeter trace is found automatically as the outer ridge of the membrane staining in the sham recording's baseline image and moved by the measured drift (at most 2 pixels), where the paper draws it by hand in MetaMorph (section 2.3); the 360 points are spaced by 1 degree of angle, not by equal arc length. For 2025-05-01 c4 the default rule (steepest outward fall) put the trace on internal staining (median radius 21.2 px), so that cell is traced with the outermost strong fall (34.1 px); the other cells keep the default rule, which the overlays show on the membrane (c3's trace cuts inside the cell on one side, away from the poles).
    • The cathodic pole angle is the median over the session's cells of the phase of a cosine fitted to the polarization profile at non-electroporating fields (83.0 degrees for 1 us, 82.1 degrees for 0.3 us, close to straight up, as in Fig. 1); the paper places the poles by the field direction. Per-cell phases (73.1 to 93.6 degrees) are shown as a variant.
    • Field strengths are the paper's labels (Fig. 2C; the Fig. 4D axis labels 357, 760, 1000, 1200, 1420, 1630, 2050, 2473 and 3320 V/cm, read from the figure on page 6 of the PDF) matched by order to the pulse amplitudes in volts that the files give; the labels are not proportional to the volts.
    • 11 cells are used where the paper reports n = 8; the dataset does not say which 8. Four cells depart from the described order of sets (c3 and c4 before the 1000 V/cm exposure, c1 and c11 after); sets are matched by their rank at each field. The notebook applies the criteria without c4, without c3 and c4, without all four, and to every choice of 8 of the 11 cells.
    • The third post-exposure 150 V/cm set exists in 2 cells and is not tested.
  • Partially reproduced

    By Eq. (2), effective membrane conductivity has little effect on charging while it stays much smaller than the cytosol and medium conductivities; a 10-fold increase gives about a 2% IMP reduction and a 100-fold increase about 12%.

    Eq. (2) as printed in the PDF gives f = 1.498 at the intact conductivity.

    Results, section 3.5, paragraph 3; Figure 5Bfig5b-eq2-sensitivity
    From the paper

    As expected, effective conductivity had little impact on charging for as long as it remained much smaller than the cytosol and media conductivities ... its 10-fold increase would go unnoticed, yielding just a ~2% IMP reduction, and a 100-fold increase would reduce IMP by just 12%.

    Result

    Eq. (2) as printed in the PDF gives f = 1.498 at the intact conductivity. 100-fold increase 11.87% reduction (11.75% against f at the intact value), within 10.8 to 13.2%. 10-fold increase 1.33% (1.20%), outside 1.8 to 2.2%; a 2% reduction needs about a 15-fold increase. The criterion gives no partial case; one of two values matching is recorded as partial.

    Deviations from the paper’s method
    • Eq. (2) is read from the PDF, as the extracted text garbles it.

Not reproduced2

  • Not reproduced

    Repeated alternating sets of 150 and 230 V/cm PEFs produced dF responses that stayed constant within each set and between sets, so that 800 flashes and 480 pulses had no obvious impact before the 1000 V/cm exposure.

    Paired t-tests of each pre-exposure 150 or 230 V/cm set against the first set of its field, per pole, n = 11…

    Results, section 3.2, paragraph 4; Figure 2C and Dverifier disagreed at firstrests on an assumptionfig2cd-nonelectroporating-stable
    From the paper

    Repeated sets of PEFs at 150 and 230 V/cm, delivered in alternation, produced ΔF responses that stayed constant both within each set and between the sets (Fig. 2C and D).

    Result

    Paired t-tests of each pre-exposure 150 or 230 V/cm set against the first set of its field, per pole, n = 11 cells (10 for the fourth 230 V/cm set). With each cell's background recording subtracted (adopted), 1 of 12 comparisons has p < 0.05, the third 150 V/cm set at the cathodic pole, 10.8% against 17.6% (p = 0.031). The annulus and darkest-pixel readings also give 1 of 12 (p = 0.045 and 0.038); without subtraction none (smallest p 0.055), which would reproduce the claim. F0 from images 2 to 40 gives 3 of 12 with the background recording. At the cathodic pole every later pre-exposure 150 V/cm set is 27 to 39% below the first, the 230 V/cm sets -11.9 to 4.7%. Within sets, the first and last 10 PEF images differ by at most 1.15% (p 0.39 or more). The outcome rests on the cells: without c3 and c4, the two whose pre-exposure sets depart from the described order, no comparison differs under any reading (smallest p 0.067, background recording), and among the 165 choices of 8 of the 11 cells none differs in 76 (background recording), 80 (annulus), 83 (floor) and 100 (none). With per-cell pole angles 2 of 12 differ. Whether the right cells were picked is open: c4, c8 and c10 have first 150 V/cm cathodic sets of 3.4 to 3.8%, against 5.0 to 15.3% for their later pre-exposure 150 V/cm sets, and c4 has the weakest cosine amplitude of the session (4.28). The result is weak, one uncorrected test of 12. The criterion is binary (not reproduced when any set differs); the background reading and the choice of cells are put to the paper's authors (findings).

    Deviations from the paper’s method
    • Background subtraction is an assumption. Section 2.3 describes dF = 100 (F - F0)/F0 with no background step, section 2.4 subtracts the background fluorescence of a cell-free region for Fluo-4, and the claims file names both readings. The adopted reading subtracts, for 2025-05-01, the mean of the cell-free background recording made with each cell (the files call it a recording in the background region without cells, so the experimenters recorded it with every cell of that session), point by point along the trace; for 2025-05-06, which has no background recordings, the per-image median of a cell-free annulus 2 to 3 radii from the cell, whose level the background recordings of the first session match within 0.97 to 1.08 times. Cell-free background is 52 to 54% of the trace intensity, and 65 to 66 counts above the darkest pixels (no dark frame or camera offset is given), and the paper's own values at 1000 V/cm (40 and 26.6%) are on the scale of the subtracted readings and about 3 times the unsubtracted ones (40/13.3 = 3.0 and 26.6/8.5 = 3.1 under window (b)). The notebook shows every reading (background recording, annulus, darkest-pixel floor, none). Round 1 adopted the annulus for both sessions; the background recording was adopted in the revision after round 1, after the results under both readings had been seen, and in that revision the annulus reading stopped meeting fig2c-1000-within-set while the background recording met it. The choice is to be read as made after the results.
    • The analysed cell is the one nearest the image centre of the cell's sham recording (an assumption; the files do not say which of the one to eight cells found in each field was analysed, and section 2.2 centres the field of view between the electrodes). The notebook draws every traced membrane on its baseline image.
    • The 6-pixel-wide perimeter trace is found automatically as the outer ridge of the membrane staining in the sham recording's baseline image and moved by the measured drift (at most 2 pixels), where the paper draws it by hand in MetaMorph (section 2.3); the 360 points are spaced by 1 degree of angle, not by equal arc length. For 2025-05-01 c4 the default rule (steepest outward fall) put the trace on internal staining (median radius 21.2 px), so that cell is traced with the outermost strong fall (34.1 px); the other cells keep the default rule, which the overlays show on the membrane (c3's trace cuts inside the cell on one side, away from the poles).
    • The cathodic pole angle is the median over the session's cells of the phase of a cosine fitted to the polarization profile at non-electroporating fields (83.0 degrees for 1 us, 82.1 degrees for 0.3 us, close to straight up, as in Fig. 1); the paper places the poles by the field direction. Per-cell phases (73.1 to 93.6 degrees) are shown as a variant.
    • Field strengths are the paper's labels (Fig. 2C; the Fig. 4D axis labels 357, 760, 1000, 1200, 1420, 1630, 2050, 2473 and 3320 V/cm, read from the figure on page 6 of the PDF) matched by order to the pulse amplitudes in volts that the files give; the labels are not proportional to the volts.
    • 11 cells are used where the paper reports n = 8; the dataset does not say which 8. Four cells depart from the described order of sets (c3 and c4 before the 1000 V/cm exposure, c1 and c11 after); sets are matched by their rank at each field. The notebook applies the criteria without c4, without c3 and c4, without all four, and to every choice of 8 of the 11 cells.
    • The fifth pre-exposure 150 V/cm set exists in one cell only and is not tested.
  • Not reproduced

    With 0.3 us PEFs at 357 to 3320 V/cm (imaged at 275 ns), the maximum dF was 53 +- 4% (about 600 mV) at both poles, similar to 1 us pulses, and its pattern with increasing field strength did not differ from that with 1 us pulses.

    Measured is the larger of the two pole maxima.

    Results, section 3.4, paragraph 5; Figure 4Dfig4d-short-pulses-same-limit
    From the paper

    Contrary to the expectations, the results were similar to those with 1-μs pulses ... the maximum ΔF reached was 53 ± 4% (~600 mV) at both cell poles. The pattern of how the response changed with increasing PEF strength was not different from that with 1-μs PEFs either.

    Result

    Measured is the larger of the two pole maxima. Annulus background (the session has no background recordings), maximum mean |dF| 34.9% at the cathodic pole (1200 V/cm) and 34.0% at the anodic pole (1630 V/cm); darkest-pixel floor 26.6 and 26.5%; without subtraction 15.0% and 16.7%; all outside 49 to 57%. Per cell, the maxima span 18.8 to 52.4% (cathodic) and 24.1 to 49.9% (anodic); three of 8 cells reach 49.6 to 52.4% at the cathodic pole. The pattern part holds under every reading; |dF| falls at every step beyond the maximum, by 82% (cathodic) and 49% (anodic) of the maximum at 3320 V/cm. Both poles' maxima are out of tolerance, so the outcome is not the partial case. The dataset holds 8 of the paper's 10 cells, so no choice of cells can be tested; the two missing cells would each need |dF| above 100% to bring the mean into range, so the outcome does not rest on the background reading or the choice of cells.

    Deviations from the paper’s method
    • Background subtraction is an assumption. Section 2.3 describes dF = 100 (F - F0)/F0 with no background step, section 2.4 subtracts the background fluorescence of a cell-free region for Fluo-4, and the claims file names both readings. The adopted reading subtracts, for 2025-05-01, the mean of the cell-free background recording made with each cell (the files call it a recording in the background region without cells, so the experimenters recorded it with every cell of that session), point by point along the trace; for 2025-05-06, which has no background recordings, the per-image median of a cell-free annulus 2 to 3 radii from the cell, whose level the background recordings of the first session match within 0.97 to 1.08 times. Cell-free background is 52 to 54% of the trace intensity, and 65 to 66 counts above the darkest pixels (no dark frame or camera offset is given), and the paper's own values at 1000 V/cm (40 and 26.6%) are on the scale of the subtracted readings and about 3 times the unsubtracted ones (40/13.3 = 3.0 and 26.6/8.5 = 3.1 under window (b)). The notebook shows every reading (background recording, annulus, darkest-pixel floor, none). Round 1 adopted the annulus for both sessions; the background recording was adopted in the revision after round 1, after the results under both readings had been seen, and in that revision the annulus reading stopped meeting fig2c-1000-within-set while the background recording met it. The choice is to be read as made after the results.
    • The analysed cell is the one nearest the image centre of the cell's sham recording (an assumption; the files do not say which of the one to eight cells found in each field was analysed, and section 2.2 centres the field of view between the electrodes). The notebook draws every traced membrane on its baseline image.
    • The 6-pixel-wide perimeter trace is found automatically as the outer ridge of the membrane staining in the sham recording's baseline image and moved by the measured drift (at most 2 pixels), where the paper draws it by hand in MetaMorph (section 2.3); the 360 points are spaced by 1 degree of angle, not by equal arc length. For 2025-05-01 c4 the default rule (steepest outward fall) put the trace on internal staining (median radius 21.2 px), so that cell is traced with the outermost strong fall (34.1 px); the other cells keep the default rule, which the overlays show on the membrane (c3's trace cuts inside the cell on one side, away from the poles).
    • The cathodic pole angle is the median over the session's cells of the phase of a cosine fitted to the polarization profile at non-electroporating fields (83.0 degrees for 1 us, 82.1 degrees for 0.3 us, close to straight up, as in Fig. 1); the paper places the poles by the field direction. Per-cell phases (73.1 to 93.6 degrees) are shown as a variant.
    • Field strengths are the paper's labels (Fig. 2C; the Fig. 4D axis labels 357, 760, 1000, 1200, 1420, 1630, 2050, 2473 and 3320 V/cm, read from the figure on page 6 of the PDF) matched by order to the pulse amplitudes in volts that the files give; the labels are not proportional to the volts.
    • 8 cells are used where the paper reports n = 10; one cell's 450 V set has no Fig. 4D field and is left out, and two cells lack the 100 V (357 V/cm) set and one the 800 V (3320 V/cm) set.

Not tested in a notebook 25

25 data missing from the dataset

Blocked25

  • Blocked

    With Di-8-ANEPPS and 1 us PEFs, polarization depolarizes the cathode-facing pole and hyperpolarizes the anode-facing pole, falls off towards the equator and scales with field strength up to 570 V/cm; at 780 V/cm the cathodic pole stops increasing and dims; at 1000 to 1400 V/cm the poles show reduced or absent polarization while regions nearer the equator remain polarized and may exceed the poles.

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us…

    Data missing from the datasetResults, section 3.1, paragraph 1; Figure 1 and legendfig1-pattern-poles-leaky
    From the paper

    At a higher electric field strength of 780 V/cm, polarization at the cathodic pole does not further increase but dims out, indicating a less efficient charging of the partially permeabilized membrane. Still stronger electric fields produce a distinct pattern of reduced or absent polarization at the poles

    Result

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us recordings only at 150, 230 and 1000 V/cm, in the alternating protocol of Fig. 2C, and the paper's data availability statement says data are available on request.

  • Blocked

    In FluoVolt-loaded cells, pole dF rose with field strength until apparent saturation at 66% (255 mV) at 360 V/cm at the cathodic pole and -83% (-320 mV) at 570 V/cm at the anodic pole; stronger fields did not increase the anodic response and decreased the cathodic one.

    Needs FluoVolt recordings; every file in the dandiset is Di-8-ANEPPS (its description says so).

    Data missing from the datasetResults, section 3.2, paragraph 2; Figure 2Afig2a-fluovolt-saturation
    From the paper

    ΔF increased proportionally to the electric field strength until reaching apparent saturation at 66% ΔF (255 mV IMP) at 360 V/cm at the cathodic pole, and −83% ΔF (−320 mV IMP) at 570 V/cm at the anodic pole. Further escalation of the electric field strength did not increase the dye response at the anodic pole and even decreased it at the cathodic pole.

    Result

    Needs FluoVolt recordings; every file in the dandiset is Di-8-ANEPPS (its description says so).

  • Blocked

    Without PEF (the first 40 images of each set) FluoVolt measurements were stable, showing no significant photosensitization or dye bleaching.

    Needs FluoVolt recordings; every file in the dandiset is Di-8-ANEPPS (its description says so).

    Data missing from the datasetResults, section 3.2, paragraph 2; Figure 2Afig2a-fluovolt-baseline-stable
    From the paper

    Without PEF (first 40 datapoints, or ~ 7 s in each set), measurements were stable, indicating no significant photosensitization or dye bleaching.

    Result

    Needs FluoVolt recordings; every file in the dandiset is Di-8-ANEPPS (its description says so).

  • Blocked

    At 1000 V/cm and above, which strongly electroporated the cells, the FluoVolt response stayed stable through the 60 pulses of each set.

    Needs FluoVolt recordings; every file in the dandiset is Di-8-ANEPPS (its description says so).

    Data missing from the datasetResults, section 3.2, paragraph 2; Figure 2Afig2a-fluovolt-stable-electroporating
    From the paper

    Field strengths of 1000 V/cm and higher caused strong electroporation (see Section 3.5), but the dye response in each set stayed stable through the 60 pulses applied

    Result

    Needs FluoVolt recordings; every file in the dandiset is Di-8-ANEPPS (its description says so).

  • Blocked

    Di-8-ANEPPS has a lower sensitivity than FluoVolt, but its dF kept rising with field strength up to 570 V/cm at both poles.

    Needs the Fig. 2B Di-8-ANEPPS escalation from 43 to 1400 V/cm, not in the dandiset.

    Data missing from the datasetResults, section 3.2, paragraph 3; Figure 2Bfig2b-di8-climbs-to-570
    From the paper

    This dye has a lower sensitivity to membrane polarization (note the vertical scale different from Fig. 2A), but ΔF kept climbing up to the electric field strength of 570 V/cm at both cell poles.

    Result

    Needs the Fig. 2B Di-8-ANEPPS escalation from 43 to 1400 V/cm, not in the dandiset. The FluoVolt comparison is missing as well.

  • Blocked

    Di-8-ANEPPS responses were somewhat affected by bleaching, most noticeably at 43 V/cm, where bleaching added about 5% to dF at the anodic pole and reduced it by about 5% at the cathodic pole.

    Needs the 43 V/cm set of the Fig. 2B escalation, not in the dandiset (no 43 V/cm recordings at all).

    Data missing from the datasetResults, section 3.2, paragraph 3; Figure 2Bfig2b-di8-bleaching-43
    From the paper

    The responses were somewhat affected by dye bleaching (particularly noticeable at 43 V/cm, where bleaching added ~5% to ΔF at the anodic pole and reduced it by the same ~5% at the cathodic pole.

    Result

    Needs the 43 V/cm set of the Fig. 2B escalation, not in the dandiset (no 43 V/cm recordings at all).

  • Blocked

    Di-8-ANEPPS responses to PEFs at and above 780 V/cm decreased gradually within each set of 60 images.

    Needs the 780 to 1400 V/cm sets of the Fig. 2B escalation, not in the dandiset.

    Data missing from the datasetResults, section 3.2, paragraph 3; Figure 2Bfig2b-di8-decline-within-set
    From the paper

    In addition, responses to PEFs at and above 780 V/cm decreased gradually in each set of 60 images, consistent with expectations of adding membrane damage by additional electroporation pulses in each set

    Result

    Needs the 780 to 1400 V/cm sets of the Fig. 2B escalation, not in the dandiset.

  • Blocked

    Fitting dF against IMPC from -150 to +150 mV with a line through the origin gave slopes of 26% (FluoVolt) and 9.1% (Di-8-ANEPPS) dF per 100 mV, with correlation coefficients of 0.96 and 0.78.

    Needs the FluoVolt calibration cells, not in the dandiset, so the criterion (both slopes) cannot be applied.

    Data missing from the datasetResults, section 3.3, paragraph 1; Figure 3 legenduses data from outside the datasetfig3-dye-slopes
    From the paper

    The correlation coefficients of the fits equaled 0.96 for FluoVolt and 0.78 for Di-8 ANEPPS (due to a lower signal-to-noise ratio), with respective slope coefficients of 26% and 9.1% ΔF per 100 mV of IMP.

    Result

    Needs the FluoVolt calibration cells, not in the dandiset, so the criterion (both slopes) cannot be applied. The Di-8-ANEPPS half under reading (b) can be approximated on the pre-exposure 150 and 230 V/cm sets of the 11 cells of 2025-05-01 (88 sets) with two assumptions the criterion does not make: a pixel size of 0.267 um (the iXon Ultra 897's 16 um pixel over the 60x objective, section 2.3; the files give none) and tau of 200 or 300 ns (the tau-radius fit of reference [20] is not available). The notebook's exploratory section gives a through-origin slope of 6.1 to 6.5% dF per 100 mV with a background subtracted and 2.6 to 2.7% without, against 9.1 +- 0.91%, with correlation 0.62 to 0.70 against 0.78. This decides no outcome.

  • Blocked

    FluoVolt measurements became non-linear already at +-200 mV, while Di-8-ANEPPS stayed essentially linear from -500 to +500 mV, so FluoVolt's early departure reflects the limit of the dye's range and not electroporation.

    Depends on fig3-dye-slopes, blocked; also needs FluoVolt data.

    Data missing from the datasetResults, section 3.3, paragraph 1; Figure 3 legenduses data from outside the datasetfig3-fluovolt-nonlinear
    From the paper

    The actual measurements with FluoVolt gradually became non-linear already at ±200 mV, while those for Di-8-ANEPPS stayed essentially linear throughout the tested range from −500 to +500 mV.

    Result

    Depends on fig3-dye-slopes, blocked; also needs FluoVolt data.

  • Blocked

    FluoVolt-measured and calculated IMP matched only at 43 and 150 V/cm; with stronger PEFs pole dF reached at most 71 +- 10% (cathodic) and -83.5 +- 5% (anodic), about +260 and -330 mV, and the cathodic value fell from 71% at 360 V/cm to 45 to 50% at 1000 to 1400 V/cm.

    Needs FluoVolt recordings; every file in the dandiset is Di-8-ANEPPS (its description says so).

    Data missing from the datasetResults, section 3.4, paragraph 1; Figure 4Auses data from outside the datasetfig4a-fluovolt-limits
    From the paper

    However, this assumption held only for the applied fields of 43 and 150 V/cm, where measured and calculated IMP matched. With stronger PEFs, maximum ΔF reached 71 ± 10% and −83.5 ± 5% at the cathodic and anodic poles, respectively. ... Notably, polarization at the cathodic pole decreased from 71% at 360 V/cm to 45–50% at 1000–1400 V/cm

    Result

    Needs FluoVolt recordings; every file in the dandiset is Di-8-ANEPPS (its description says so).

  • Blocked

    With Di-8-ANEPPS, measured IMP fell below the calculated value when the field reached 570 V/cm, together with the maximum dF of 57 +- 14% at the cathodic pole and -55 +- 4% at the anodic pole, a polarization of over 600 mV, twice that measured with FluoVolt.

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us…

    Data missing from the datasetResults, section 3.4, paragraph 2; Figure 4Buses data from outside the datasetfig4b-di8-threshold-570
    From the paper

    The measured IMP decreased below the calculated value when the electric field reached 570 V/cm, concurrently with reaching the maximum ΔF of 57 ± 14% at the cathodic pole and − 55 ± 4% at the anodic pole. These values corresponded to membrane polarization by over 600 mV

    Result

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us recordings only at 150, 230 and 1000 V/cm, in the alternating protocol of Fig. 2C, and the paper's data availability statement says data are available on request.

  • Blocked

    Averaging dF over the first 10 of the 60 PEFs, cathodic pole polarization reached 66 +- 15% (710 +- 200 mV), above the 600 mV maximum averaged over 60 PEFs.

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us…

    Data missing from the datasetResults, section 3.4, paragraph 3; Figure 4B (dotted lines)fig4b-first10-cathodic
    From the paper

    Polarization measured this way reached 66 ± 15% (710 ± 200 mV) at the cathodic pole, suggesting that the 600-mV maximum, averaged from 60 PEFs, was not the dye limit but the actual IMP

    Result

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us recordings only at 150, 230 and 1000 V/cm, in the alternating protocol of Fig. 2C, and the paper's data availability statement says data are available on request.

  • Blocked

    Above 780 V/cm the IMP reached at the poles decreased progressively with field strength, more at the cathodic pole; at 1400 V/cm charging was no longer detectable at the cathodic pole and dropped to about 30% dF (about -330 mV) at the anodic pole.

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us…

    Data missing from the datasetResults, section 3.4, paragraph 4; Figure 4Bfig4b-asymmetric-decline
    From the paper

    As the electric field increased further, the IMP reached at the poles progressively decreased, and the reduction was more pronounced at the cathodic pole. ... At 1400 V/cm, charging was no longer detectable at the cathodic pole (i.e., the membrane became fully permeable) and dropped to ~30% ΔF (~ −330 mV) at the anodic pole.

    Result

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us recordings only at 150, 230 and 1000 V/cm, in the alternating protocol of Fig. 2C, and the paper's data availability statement says data are available on request.

  • Blocked

    Membrane regions nearer the equator appeared unaffected and followed the cosine dependence predicted by the Schwan equation up to 1000 V/cm, even when the poles were electroporated.

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us…

    Data missing from the datasetResults, section 3.4, paragraph 4; Figure 4Cuses data from outside the datasetfig4c-equator-cosine
    From the paper

    Membrane areas closer to the equator (at polar angles closer to 0◦and 270◦) appeared relatively unaffected and followed the cosine dependence predicted by Schwan formula up to 1000 V/cm (Fig. 4C).

    Result

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us recordings only at 150, 230 and 1000 V/cm, in the alternating protocol of Fig. 2C, and the paper's data availability statement says data are available on request.

  • Blocked

    1 mM Gd3+ extended membrane charging at the anodic pole down to -864 +- 44 mV, against -542 +- 57 mV in parallel controls (p < 0.001).

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

    Data missing from the datasetResults, section 3.5, paragraph 1; Figure 5Afig5a-gd-anodic-extension
    From the paper

    Indeed, we found that 1 mM Gd3+ extended the range of membrane charging at the anodic pole down to −864 ± 44 mV (p < 0.001 compared to −542 ± 57 mV in parallel control experiments, Fig. 5A).

    Reported statistics
    • t-test (2-tailed t-test in the Fig. 5A legend; Student's t-test in Methods 2.5), p < 0.001 (n = 7 cells with Gd3+ and 5 control cells)
    Result

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

  • Blocked

    With Gd3+, measured IMP stayed nearly identical to IMPC down to -780 mV, showing that the Di-8-ANEPPS response stayed linear and its calibration valid at high IMPs.

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

    Data missing from the datasetResults, section 3.5, paragraph 1; Figure 5Auses data from outside the datasetfig5a-gd-linear-to-780
    From the paper

    Furthermore, measured IMP remained nearly identical to the theoretical IMPC down to −780 mV, indicating that the dye response remained linear and its calibration was valid even at high IMPs.

    Result

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

  • Blocked

    At the cathodic pole, polarization with Gd3+ reached 647 +- 44 mV, not significantly higher than in controls, but Gd3+ prevented the progressive decline of IMP as field strength increased.

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

    Data missing from the datasetResults, section 3.5, paragraph 2; Figure 5Afig5a-gd-cathodic
    From the paper

    At the cathodic pole, polarization in the presence of Gd3+ reached 647 ± 44 mV, a value not significantly higher than that in the control group without Gd3+. However, Gd3+ prevented the progressive decline in IMP as the electric field was increased.

    Result

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

  • Blocked

    Differences between Gd3+ and control data are significant at p < 0.05 or better for the datapoints below -700 mV and above 1200 mV.

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

    Data missing from the datasetFigure 5A legenduses data from outside the datasetfig5a-gd-significant-points
    From the paper

    Differences between Gd3+ and control group data are significant at p < 0.05 or better (2-tailed t-test) for datapoints below −700 mV and above 1200 mV.

    Reported statistics
    • 2-tailed t-test, p < 0.05 (n = 7 cells with Gd3+ and 5 control cells)
    Result

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

  • Blocked

    For most datapoints, Gd3+ reduced the electroporation-induced effective membrane conductivity 2 to 3 fold.

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset.

    Data missing from the datasetResults, section 3.5, paragraph 4; Figure 5Cuses data from outside the datasetfig5c-gd-reduces-conductivity
    From the paper

    For most datapoints, Gd3+ reduced the electroporation- induced effective conductivity 2–3-fold.

    Result

    Needs the Gd3+ (n = 7) and parallel control (n = 5) experiments of Fig. 5A, not in the dandiset. Its dependency fig5b-eq2-sensitivity was tested.

  • Blocked

    A single 1 us pulse at 0 to 1200 V/cm produced a clear Ca2+ entry at 1000 and 1200 V/cm, with the signal elevated through the 5 min observation; the small increase after 780 V/cm was at the detection limit and not significant.

    Needs Fluo-4 calcium imaging, not in the dandiset.

    Data missing from the datasetResults, section 3.6, paragraph 2; Figure 6Afig6a-single-pulse-ca
    From the paper

    Exposure to a single 1-μs pulse at escalating field strengths, from 0 to 1200 V/cm established a clear peak of Ca2+ entry at 1000 and 1200 V/ cm, and Ca2+ signal remained elevated through the 5-min observation period (Fig. 6A). A subtle ΔF increase after exposure at 780 V/cm was at the detection limit and not statistically significant.

    Result

    Needs Fluo-4 calcium imaging, not in the dandiset.

  • Blocked

    With trains of 60 1 us pulses at 6 Hz (224 cells, each tested once), a strong Ca2+ response occurred in 28% of cells at 780 V/cm and nearly all cells at higher fields; at 650 V/cm only 2 cells (5.9%) responded strongly, but the mean signal at the end of recording was significantly above zero (p < 0.001, one-sample t-test) and marginally higher than at 230 V/cm (p < 0.05, single-tailed t-test).

    Needs Fluo-4 calcium imaging (224 cells), not in the dandiset.

    Data missing from the datasetResults, section 3.6, paragraph 3; Figure 6Bfig6b-train-ca
    From the paper

    A strong Ca2+ response was recorded in 28% of cells exposed at 780 V/cm and in nearly all cells at higher intensities (Fig. 6B). At 650 V/cm, only 2 cells (5.9%) showed a strong response, but the mean Ca2+ signal by the end of recording was significantly different from zero (p < 0.001, one sample t-test) and marginally higher than after exposure at 230 V/cm (p < 0.05, single-tailed t-test).

    Reported statistics
    • 650 V/cm, end-of-recording dF against zero: one sample t-test, p < 0.001
    • 650 V/cm against 230 V/cm, end-of-recording dF: single-tailed t-test, p < 0.05
    Result

    Needs Fluo-4 calcium imaging (224 cells), not in the dandiset.

  • Blocked

    Polarization by a 150 V/cm test pulse 5 us after a conditioning pulse still followed a cosine after conditioning PEFs up to 1000 V/cm, while 1200 and 1400 V/cm conditioning PEFs markedly hindered charging at the cell poles.

    Needs the two-pulse (conditioning and 150 V/cm test pulse) experiments of Fig. 7A, not in the dandiset.

    Data missing from the datasetResults, section 3.7, paragraph 3; Figure 7Afig7a-test-pulse-cosine
    From the paper

    Polarization still followed a cosine function after conditioning PEFs of up to 1000 V/cm. However, 1200 and 1400 V/cm conditioning PEFs markedly hindered charging by the test pulse at cell poles, indicating a persistent membrane permeabilization.

    Result

    Needs the two-pulse (conditioning and 150 V/cm test pulse) experiments of Fig. 7A, not in the dandiset.

  • Blocked

    During the conditioning pulse, pole polarization normalized to 150 V/cm fell 1.5 times below linear scaling at 560 V/cm, 2-fold at 760 V/cm and further for stronger PEFs (p < 0.01 for all points at 560 V/cm and above, one-sample t-test).

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us…

    Data missing from the datasetResults, section 3.7, paragraph 5; Figure 7B, top panelfig7b-conditioning-sublinear
    From the paper

    Actual measurements fell 1.5 times below this line for 560 V/cm PEFs, 2- fold for 760 V/cm PEFs, and diverged further for more intense PEFs (p < 0.01 for all datapoints ≥560 V/cm, one sample t-test).

    Reported statistics
    • one sample t-test, p < 0.01 (n = 5 cells)
    Result

    Needs the Di-8-ANEPPS 1 us escalation from 43 to 1400 V/cm (the Fig. 4B group, n = 5); the dandiset holds 1 us recordings only at 150, 230 and 1000 V/cm, in the alternating protocol of Fig. 2C, and the paper's data availability statement says data are available on request. Section 3.7 says the top panel of Fig. 7B uses the Fig. 4B data.

  • Blocked

    Polarization by the test pulse 6 us after the conditioning pulse did not differ from control up to 760 V/cm conditioning, was about 80% of control after 1000 V/cm (not significant), and was reduced to about 70% and 50% after 1200 and 1400 V/cm (p < 0.05 and p < 0.01).

    Needs the two-pulse (conditioning and 150 V/cm test pulse) experiments of Fig. 7A, not in the dandiset.

    Data missing from the datasetResults, section 3.7, paragraph 5; Figure 7B, bottom panelfig7b-test-pulse-recovery
    From the paper

    In contrast, measurements 6 μs later (test pulse) did not differ from the control up to 760 V/cm strength of the conditioning PEF; they were at ~80% of the control reading after 1000 V/cm conditioning PEF but the difference was not statistically significant. Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test).

    Reported statistics
    • 1200 V/cm conditioning against control: two-sided t-test, p < 0.05 (n = 5 cells)
    • 1400 V/cm conditioning against control: two-sided t-test, p < 0.01 (n = 5 cells)
    Result

    Needs the two-pulse (conditioning and 150 V/cm test pulse) experiments of Fig. 7A, not in the dandiset.

  • Blocked

    Effective membrane conductivity at the poles dropped about 10-fold (range 7 to 20) within 6 us after the electroporating pulse; the cathodic pole was more conductive during the pulse but no pole difference was seen by the test pulse; after 570 and 760 V/cm the membrane resealed fully within 6 us, while stronger PEFs left residual conductivity.

    Depends on fig7b-conditioning-sublinear and fig7b-test-pulse-recovery, both blocked for missing data.

    Data missing from the datasetResults, section 3.7, paragraphs 6 and 7; Figure 7Cfig7c-fast-resealing
    From the paper

    Fig. 7C shows a profound reduction in the λm,eff within just 6 μs after the electroporating pulse. For most datapoints, it dropped by a factor of 10 ... 7–20). While the cathodic pole became more conductive than the anodic pole during the electroporating pulse ... no difference between the poles was detected by the test pulse. For mildly electroporating PEFs of 570 and 760 V/cm, membrane resealed fully (within the accuracy of measurements) within just 6 μs.

    Result

    Depends on fig7b-conditioning-sublinear and fig7b-test-pulse-recovery, both blocked for missing data.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Paper inconsistentEq. (2) with the constants of Methods 2.3 gives a 1.33% IMP reduction for a 10-fold rise of membrane conductivity, where Results 3.5 states about 2%; the 100-fold value (11.87%) matches the stated 12%.#
  • Paper inconsistentResults 3.5 states that a 10-fold rise in effective membrane conductivity yields a ~2% IMP reduction by Eq. (2), but Eq. (2) with the constants of Methods 2.3 gives 1.33% (1.20% relative to the intact membrane); a 2% reduction needs a 15- to 16-fold rise. The 100-fold value (12%) agrees.#
  • Methods not availableQuestion for the authors. Where were the background ROIs of the strobe images placed, and how far from the membrane? Reference [20] says near the poles outside the cell. Here a background 2 to 4 um out, 8 to 10 um out, or none changes the pole dF by up to a factor of three (FluoVolt cathodic at 360 V/cm 78.5, 49.4 and 23.7%), and the 8 to 10 um reading was assumed. A sweep of 6-pixel bands from 8 to 44 pixels out shows the band 14 to 20 pixels (4 to 5 um) out would bring the FluoVolt saturation values, both Fig. 3 slopes and the first-10 Di-8-ANEPPS maximum within the paper's values.#
  • Methods not availableQuestion for the authors. What is the pixel size of the images, and how was the cell radius measured? With 16-um camera pixels behind the 60x objective (0.267 um) the cells have mean radii of 7.8 to 15.1 um, larger than the 8 um the paper gives as typical, and the dye slopes of Fig. 3 come out 21.6 and 7.4% per 100 mV; with 0.192 um (radius 8 um) they come out 26.6 and 9.5, as in the paper.#
  • Methods not availableQuestion for the authors. Which generator amplitude in the files corresponds to each field strength of the paper (is 25 V the 43 V/cm set, and so on), and which cells form the n = 4 FluoVolt and n = 5 Di-8-ANEPPS groups of Fig. 2 and 4? Both were assumed here (amplitudes matched in order; four FluoVolt cells with exactly nine sets; all eight Di-8-ANEPPS cells, with the 56 five-cell subsets shown).#
  • Paper inconsistentResults 3.5 says a 10-fold rise of the effective membrane conductivity reduces IMP by about 2%; Eq. (2) with the constants of Methods 2.3 gives 1.3% (a 2% reduction needs a 15-fold rise). The 100-fold value (12%) agrees with the equation.#
  • Methods not availableQuestions for the paper's authors. (1) What field strength in V/cm does each pulse amplitude in the files correspond to, and are these the escalations of Fig. 2A, 2B and 3 or other experiments? The attempt assumed 1400 V/cm at 250 V (5.6 V/cm per volt), from the electrode geometry, and ran 1.5 to 8. (2) Which cell in each field of view was analysed? The attempt ran experiment means, the cell nearest the image centre and all cells. (3) Was background subtracted from the laser images, as for Ca2+ (Methods 2.4)? The attempt subtracted the cell-free median; without it dF halves. (4) What is the pixel size? The attempt assumed 0.267 um.#
  • Paper inconsistentEq. (2) with the constants the Methods give (lambda_i 0.4 S/m, lambda_o 1.64 S/m, R 8 um, d 5 nm, lambda_m 3e-7 S/m) gives a 1.3% IMP reduction for a 10-fold rise in membrane conductivity, while Results 3.5 says about 2%; the 100-fold value (11.9%) agrees with the stated 12%.#
  • Methods not availableQuestion for the authors. How were generator voltages converted to the field strengths of Fig. 6, and was the same conversion used for single pulses and trains? 3.9 V/cm per V fits the fields and group sizes of Fig. 6B and was adopted; 3.3 V/cm per V puts the train voltages on the three fields named in the text and was run as a variant. No outcome changes between the two.#
  • Methods not availableQuestion for the authors. How was a strong Ca2+ response defined in Fig. 6B, how large was the region over each cell, and which cells formed each group? The count of 2 responders at 650 V/cm is met under one of 36 combinations of conversion, rule and region size here.#
  • Methods not availableQuestion for the authors. Unpulsed cells lose 12% (single-pulse session) and 16% (train session) of their background-corrected Fluo-4 signal by the end of a recording, relative to the pre-pulse mean; the raw cell signal falls by 8.7 and 7.5% while the cell-free background falls by 1.0 and 0.6%. The 0 V/cm trace of Fig. 6A rises by about 1% and the Fig. 6B traces are flat. Were the dF traces of Fig. 6 corrected for this decline, or do they come from other recordings, and which test gave "not statistically significant" at 780 V/cm? Without a correction the end-of-recording dF at 1000 and 1200 V/cm is below zero, and fig6a-ca-sustained is not reproduced.#
  • Paper inconsistentEq. 2 with the constants of Methods 2.3 gives a 1.3% reduction of pole IMP for a 10-fold increase of membrane conductivity, where Section 3.5 states about 2%.#
  • OtherEach field of view was recorded first without a pulse and then at escalating voltages, and the decline of the Fluo-4 signal is steepest in the first recording (before the pulse, -3.97% per min in the first recording of the single-pulse session and -0.41 to -1.46% per min in the fifth to seventh, slowing with each recording; -11.4% per min in the first recording of the train session and -2.0 to -5.4% per min in later ones, without a steady trend). Field strength and recording order therefore go together, and comparisons with the sham, always recorded first, include part of this difference.#
  • Selection not documentedSix cells (c5 to c10) have the paper's 5-us interval where Fig. 7 reports n = 5, and nothing says which five were used. Four more cells (c1 to c4) have a 1-us interval, which the paper does not report.#
  • Methods not availableFor the paper's authors, whether a background was subtracted from the potentiometric images and whether images without a laser flash were kept when the 40 baseline and 60 pulse images were collapsed. Background removal doubles the dF scale here (5.6% to 12.6% at 150/150), and only the background-subtracted scale matches the paper's.#
  • OtherThe images fade through each set of 100. Over the 40 baseline images the membrane trace intensity (background removed) falls by about 0.10% per image in 43 of 44 files of the 5-us cells, which would predict a uniform dF of -5.16% over the 60 pulse images; the profiles' mean dF is -3.67% over these files and -4.3% at the control, and the two correlate weakly over files (r 0.18). The sign is that of the Di-8-ANEPPS bleaching the paper reports (Results 3.2), the size does not match, and the offset's source is not established; nothing in the files corrects or marks it.#
  • Methods not availableQuestion for the paper's authors. Was a background subtracted from the potentiometric images before computing dF, and if so which: the cell-free background recording made with each 2025-05-01 cell, a cell-free region of the same image, or the camera offset? Section 2.3 describes none; section 2.4 subtracts a cell-free region for Fluo-4. Cell-free background is 52 to 54% of the membrane intensity in these files, so dF without subtraction is about 40% of dF with it. This attempt assumed subtraction of the background recording (and of a cell-free annulus for 2025-05-06). The outcomes of fig2cd-nonelectroporating-stable (not reproduced with subtraction, reproduced without) and fig2c-1000-within-set (reproduced with the background recording only) depend on the answer.#
  • Methods not availableQuestion for the paper's authors. Which cell in each field of view, and which 8 of the 11 cells of the 2025-05-01 session, form Fig. 2C and D, and are 10 cells of Fig. 4D in the dandiset (it holds 8)? This attempt used the cell nearest the image centre and every cell in the dandiset. Without c3 and c4, the two cells whose pre-exposure sets depart from the described order, all three Fig. 2C and D claims are met; among the 165 choices of 8 cells they are met together in 1 (background recording reading).#
  • Paper inconsistentEq. (2) as printed, with the parameters of section 2.3, gives a 1.3% IMP reduction for a 10-fold increase of membrane conductivity, where section 3.5 states ~2% (the 100-fold value, 11.9%, matches the stated 12%).#

Questions about the claims 7

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • openasked 2026-11-02about fig7a-cosine-profiles

    The claims file's header reads the dandiset's title and description as pointing at the two-pulse recovery experiment of Fig. 7 (Results 3.7), adds fig7a-cosine-profiles because "Fig. 7 is this dandiset's experiment", and plans collapsing 20 and 40 images as the only deviation. The files name FluoVolt with a FITC cube in all 72 sets, 1.00-mm electrodes, single pulses and pairs at 50 to 250 V (described as 0.15 to 1.57 kV/cm) and intervals of 1, 5, 25, 125 and 250 us, where Fig. 7 used Di-8-ANEPPS, 1.6-mm electrodes, conditioning at 150 to 1400 V/cm and a 5-us interval only. Should the header and the Fig. 7 claims (fig7a-cosine-profiles, fig7b-charging-during-pulse, fig7ab-test-pulse-recovery, fig7c-fast-conductivity-drop, fig7c-full-reseal-mild) say that the dandiset holds a FluoVolt two-pulse experiment the paper does not report, and that no claim can be tested on it?

    Passage. Each conditioning pulse was followed in 5 us with a 1-us, 150 V/cm test pulse (Results 3.7); Cells loaded with Di-8-ANEPPS (Fig. 7 legend); two tungsten rods 1.6 mm apart (Methods 2.2); and Future studies should focus on the time course of membrane recovery, perhaps using the same two-pulse protocol as in Fig. 7, but varying the time interval between the pulses (Discussion).

    Why it matters. The outcomes do not change. All five Fig. 7 claims are blocked as data_missing because the dye, field levels, electrode spacing and number of cells differ from the paper's, as the claims file's criteria name Di-8-ANEPPS and n = 5. If the reader kept the premise, a later attempt might be asked to test the Fig. 7 criteria on the dataset's FluoVolt 5-us pairs (c2, c9), which the notebook shows only as a variant.

    No reader has answered it yet.
  • openasked 2026-11-02about fig2a-fluovolt-stable

    Should the criterion of fig2a-fluovolt-stable allow for the number of tests it makes? Each start/end reading runs 24 paired t-tests at p < 0.05 with n = 4 (6 pulse comparisons at 1000 to 1400 V/cm and 18 baseline comparisons), and the claim fails if any one of them is significant. With no change at all, the chance that at least one of 24 independent tests falls below 0.05 is about 70% (1 - 0.95^24), so the criterion fails a stable recording more often than not. A reading that corrects for the number of tests (for example Bonferroni or Holm over the 24), or that asks for a change larger than some size in % dF, would test what the paper says.

    Passage. Without PEF (first 40 datapoints, or ~ 7 s in each set), measurements were stable, indicating no significant photosensitization or dye bleaching ... but the dye response in each set stayed stable through the 60 pulses applied (Results 3.2, paragraph 2); the Fig. 2 legend names a 2-tailed paired t-test. The paper reports no test for this statement and does not say how many comparisons it made.

    Why it matters. Under the adopted far background the claim fails on 2 significant tests of 24 under reading (a) and 5 under reading (b), with changes of 2.5 to 7.0% dF against responses of 40 to 70%. Under reading (b) the smallest p is below 0.0005 (360 V/cm cathodic baseline, -4.2%) and the next is 0.002, so a Bonferroni correction over 24 tests (p < 0.0021) would leave one or two significant baseline changes; under reading (a) it would leave none (smallest p 0.005), so the readings would disagree and the claim would become blocked (methods_underspecified) under the criterion's own rule for disagreeing readings.

    No reader has answered it yet.
  • openasked 2026-11-03about fig6a-780-not-significant

    The criterion judges the claim of absence by a one-sample t-test of each cell's end-of-recording dF against zero. Can that test stand for the paper's "not statistically significant", when the same claims file treats 1000 and 1200 V/cm as a clear entry? In this dataset that test finds no increase at 1000 and 1200 V/cm either, so it cannot detect the effect the claim says is absent at 780 V/cm. Should the test be the one that detects the entry at 1000 and 1200 V/cm (for example against the 0 V/cm group, or on the change at the pulse), with the claim of absence judged against that?

    Passage. Exposure to a single 1-us pulse at escalating field strengths, from 0 to 1200 V/cm established a clear peak of Ca2+ entry at 1000 and 1200 V/cm, and Ca2+ signal remained elevated through the 5-min observation period (Fig. 6A). A subtle dF increase after exposure at 780 V/cm was at the detection limit and not statistically significant. (Section 3.6, paragraph 2; Methods 2.5 name Student's t-test and the one-sample t-test.)

    Why it matters. Unpulsed cells decline to -12% by the end of the recording here, so the end value is below zero at 780, 1000 and 1200 V/cm (under 3.9 V/cm per V, -7.42, -5.44 and -3.83%) and the criterion's test gives "reproduced" without being able to find any increase. Against the 0 V/cm group the end value and the peak are significantly higher at 780 V/cm (p = 1.3e-06 and 0.021), which would give "not reproduced"; the step of dF at the pulse against the 0 V/cm group detects 1000 and 1200 V/cm (p = 0.025 and 3e-07) and not 780 V/cm (p = 0.10), which would give "reproduced". The verifier of round 1 reported the criterion's test as unable to detect an increase. The verifier of round 2 noted that the step reading is marginal at 1000 V/cm (p = 0.058 against zero) and that the steps at 780 and 1000 V/cm were not shown to differ; they do not (p = 0.40), so no reading here both detects 1000 V/cm clearly and finds 780 V/cm absent.

    No reader has answered it yet.
  • answered 2026-11-02asked 2026-11-02about fig7b-test-pulse-unchanged-to-760

    The criterion makes the claim methods_underspecified when the paired and the unpaired two-sided t-test disagree. Does the paper not settle the reading? Results 3.7 reports the 360 V/cm cathodic test-pulse point, which reaches about 120% of control, as p > 0.1, and the Fig. 7B legend tests the difference "from the undamaged membrane (gray area between horizontal dashed lines)", a band with its own spread. Both fit an unpaired comparison with the control group more than a paired one. Should the criterion take the unpaired test as the paper's, with the paired test as a variant?

    Passage. Also, an accidental ΔF peaking to 120% (p > 0.1, lower panel in Fig. 7B) was considered as 100% for interpolation. (Results 3.7, paragraph 6); * p < 0.05, ** p < 0.01 with a two-way t-test for the difference from the undamaged membrane (gray area between horizontal dashed lines). (Fig. 7B legend)

    Why it matters. On the dataset the cathodic test response after 360 V/cm is 133% of control; the paired test gives p = 0.0038 and the unpaired p = 0.61. The paired test finds a difference in 16 of 18 variants and the unpaired test in none, so the claim is blocked under the criterion as written and would be reproduced (80.0% of control at 1000 V/cm, within 80 +- 8) under the unpaired reading. The same choice bears on fig7a-test-pulse-cosine-up-to-1000 and fig7b-test-pulse-reduced-1200-1400, which take their tests from this claim.

    The reader’s answer. Changed. The paper settles the reading. The Fig. 7B legend tests "the difference from the undamaged membrane (gray area between horizontal dashed lines)", a comparison with the control group and its spread; the Methods name only "Student's t-test and one-sample t-test"; and the paper writes "paired" where it pairs ("2-tailed paired t-test", Fig. 2D legend) but not for Fig. 7B or in Results 3.7 ("two-sided t-test"). The criterion of fig7b-test-pulse-unchanged-to-760 now takes the unpaired two-sample two-sided t-test against the control group as the paper's test, shows the paired test and the one-sample test as variants, and drops the methods_underspecified rule. fig7b-test-pulse-reduced-1200-1400 now uses the same test, with only the pole readings left open, and fig7a-test-pulse-cosine-up-to-1000 refers to that test in place of its readings. Expected values and statements are unchanged.
  • openasked 2026-11-03about fig7b-test-pulse-reduced-1200-1400

    The criterion allows the cathodic, anodic and mean-of-poles readings for the ~70% and ~50% test-pulse values. Results 3.7 paragraph 6 says one dF value, the cathodic pole at 1400 V/cm, was negative and was omitted from Fig. 7C. If that value is the test-pulse value of the lower panel of Fig. 7B, the paper's ~50% after 1400 V/cm cannot be a cathodic or a mean-of-poles value, and only the anodic reading can carry the 70% and 50%. Should the criterion keep only the anodic reading? Or is the omitted value the conditioning-pulse value of the top panel, so that the readings stand?

    Passage. One ΔF value (cathodic pole at 1400 V/cm) was omitted because it was negative, perhaps being a measurement error due to dye bleaching. (Results 3.7, paragraph 6); Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test) (Results 3.7, paragraph 5)

    Why it matters. Raised by the round-2 verifier. On the dataset, under the main reading, both reductions are significant at the cathodic pole (25.2% and -11.3% of control, unpaired p 0.022 and 0.0010) and for the mean of poles (53.4% and 27.2%, p 0.0013 and 0.0002), with values outside tolerance, which the criterion calls partially reproduced. The anodic pole is within tolerance (68.7% and 48.0%) but p 0.086 and 0.011, short of p < 0.05 and p < 0.01, so under the anodic reading alone the claim would be not reproduced. The anodic reading meets the whole criterion in none of 22 variants.

    No reader has answered it yet.
  • openasked 2026-11-03about fig7c-full-reseal-mild-residual-strong

    The criterion tests "no difference between the poles was detected by the test pulse" at every strength, 1400 V/cm included. The paper's sentence refers to Fig. 7C, which leaves out the negative cathodic dF at 1400 V/cm. Should the pole comparison at the test pulse cover only the strengths Fig. 7C shows (360 to 1200 V/cm at the cathodic pole)?

    Passage. One ΔF value (cathodic pole at 1400 V/cm) was omitted because it was negative (Results 3.7, paragraph 6); Fig. 7C shows a profound reduction in the λm,eff ... While the cathodic pole became more conductive than the anodic pole during the electroporating pulse (Fig. 7B, see also Figs. 1 and 4B–D), no difference between the poles was detected by the test pulse. (Results 3.7, paragraph 7)

    Why it matters. Raised by the round-2 verifier. On the dataset the paired test finds a pole difference after 1400 V/cm (cathodic minus anodic -59.3 points of control, p 0.0002) and none at 360 to 1200 V/cm (smallest p 0.12; in 21 of 22 variants). The part fails as the criterion is written and holds with 1400 V/cm left out. The outcome, partially reproduced, rests on the reseal and residual parts and does not change either way.

    No reader has answered it yet.
  • openasked 2026-11-03about fig2d-lasting-reduction

    The Fig. 2 legend gives the reduction as "small (≤20%)", the text of section 3.2 as "about 20%", and the claim's statement repeats both, while the criterion's tolerance is 20 +- 2%, symmetric about 20. Should a reduction below 18% (for example 10 to 18%, which the legend's "≤20%" allows) count as within the expected value, that is, should the tolerance be one-sided (0 to 22%, or up to 20%)?

    Passage. Note the lack of changes until electroporation by a 1000 V/cm PEF and a small (≤20%) but persistent reduction of ΔF after it. (Fig. 2 legend); ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05). (Results, section 3.2)

    Why it matters. Raised by the round-1 verifier. In this attempt every set reduction with p < 0.05 is above 22% (26.0% or more for both poles averaged), and the anodic pole's mean reductions below 18% (12.5 to 17.5% across readings) come either with no set at p < 0.05 or with a pre-exposure set that differs, so a one-sided tolerance would not change the outcome here. A later attempt with other cells could fall in that range.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Membrane charging and lesioning by pulsed electric fields (Semenov et al. 2026)

Tests the findings of Semenov et al. (2026) on dandiset 001515, which holds FluoVolt strobe-imaging time courses of CHO cells charged by single 1-us pulses at one amplitude per cell. None of the paper's experiments (sets of 40 baseline and 60 pulse images at 900 ns with field escalation, Di-8-ANEPPS, 0.3-us pulses, Gd3+, two-pulse and Ca2+ recordings) is in it, so 33 of 34 claims are blocked; the one computation from the paper's Eq. (2) is tested. The notebook checks what the files hold. All files

Environment: Python 3.13, 101 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Membrane charging and recovery after pulsed electric fields (Semenov et al. 2026)

Tests the findings of Semenov, Silkuniene, Silkunas, Pakhomova, Bixler, Ibey, Kochunov and Pakhomov (2026) on dandiset 001516. The dandiset holds a FluoVolt two-pulse experiment in CHO cells, with inter-pulse intervals of 1 to 250 us and fields of 150 to 1570 V/cm, which the paper does not report; none of the recordings behind the paper's figures is in it. The one claim that is a computation from the paper's Eq. (2) is tested, and the dataset's own sets are measured with the paper's pole method. All files

Environment: Python 3.13, 20 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Membrane charging and electroporation imaged with strobe fluorescence (Semenov et al. 2026)

Tests the findings of Semenov, Silkuniene, Silkunas, Pakhomova, Bixler, Ibey, Kochunov and Pakhomov (2026) on dandiset 001517, which holds raw strobe images of CHO cells loaded with FluoVolt or Di-8-ANEPPS and exposed to 1-us pulses of escalating amplitude. Pole polarization, its decline within and across sets, the dye calibration against the Schwan equation and the departure from linear charging are rebuilt from the images. The Gd3+, 0.3-us, two-pulse, alternating-amplitude and Ca2+ experiments are not in the dandiset. All files

Environment: Python 3.13, 27 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Membrane charging measured with FluoVolt and Di-8-ANEPPS (Semenov et al. 2026)

Tests the findings of Semenov, Silkuniene, Silkunas, Pakhomova, Bixler, Ibey, Kochunov and Pakhomov (2026) on dandiset 001518, which holds ten escalations of 1-us pulses from 25 to 250 V, five with each dye, imaged by pulsed laser microscopy. It tests the calibration of the two dyes, the FluoVolt and Di-8-ANEPPS responses up to electroporating fields, and Eq. (2) of the paper. The files give the pulse in volts; the factor to V/cm is assumed from the electrode geometry (1400 V/cm at 250 V) and every criterion is also run over a range of factors. The alternating, 0.3-us, Gd3+, Ca2+ and two-pulse experiments are not in the dandiset. All files

Environment: Python 3.13, 27 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Ca2+ uptake after 1-us pulses in CHO cells (Semenov et al. 2026)

Tests the findings of Semenov, Silkuniene, Silkunas, Pakhomova, Bixler, Ibey, Kochunov and Pakhomov (2026) that can be tested on dandiset 001521, which holds the Fluo-4 imaging of CHO cells after single 1-us pulses and after 60-pulse trains (Fig. 6). It segments the cells, computes dF for each, and compares field strengths under two readings of the voltage to field conversion. The potentiometric imaging of Figures 1 to 5 and 7 is not in the dandiset. All files

Environment: Python 3.13, 106 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Membrane recovery after 1-us electroporation (Semenov et al. 2026)

Tests the findings of Semenov et al. (2026) that dandiset 001525 can test. The dandiset holds the two-pulse strobe imaging of ten Di-8-ANEPPS-loaded CHO cells, a conditioning pulse followed by a 150 V/cm test pulse, the experiment of the paper's Fig. 7A and the bottom panel of Fig. 7B. The notebook measures the test-pulse polarization around each cell's perimeter and at its poles, and computes the conductivity calibration of Eq. (2). The other experiments of the paper are not in the dandiset. All files

Environment: Python 3.13, 25 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Membrane charging and lesioning by pulsed electric fields in CHO cells (Semenov et al. 2026)

Tests the findings of Semenov, Silkuniene, Silkunas, Pakhomova, Bixler, Ibey, Kochunov and Pakhomov (2026) on dandiset 001526, which holds Di-8-ANEPPS strobe images of 19 CHO cells, the alternating 150 and 230 V/cm protocol around a 1000 V/cm exposure (Fig. 2C and D) and the 0.3 us escalation (Fig. 4D). It traces each cell's membrane, measures pole dF per image and per set, and evaluates Eq. (2). The FluoVolt, 1 us escalation, Gd3+, Ca2+ and two-pulse experiments are not in the dandiset. All files

Environment: Python 3.13, 29 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

Attempt semenov-2026-01

  • Round 1
    2026-11-02
    Agreed with 34 of 34 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook), round 1. Reviewed: The handover of the first run, the executed notebook with the conclusions and summary removed, the helper module and the claims file, with the paper under paper/. The verifier also queried the DANDI API for the pinned and draft versions (292 NWB files, 7.47 GB in each). It could not run the pixel- level helpers (no numpy or h5py in its environment), so the cell counts, signs and amplitude ordering of cells 7 to 13 were taken from the notebook.
  • Round 2
    2026-11-02
    Agreed with 34 of 34 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook), round 2. Reviewed: The full executed notebook of the revised run with its conclusions and summary, the helper module, the claims file and the attempt record, with the paper under paper/. The verifier rebuilt the derived statistics of cells 13 to 17 from the per-file table of cell 9 and checked reading (b) over the grid of cell 21 (0 combinations). It still could not run the pixel-level helpers (no numpy or h5py in its environment) and did not examine dandisets 001516 to 001518.

Attempt semenov-2026-02

  • Round 1
    2026-11-02
    Agreed with 32 of 32 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The first executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper. The verifier checked the dye, electrodes and intervals of all 72 assets in the archive's metadata and recomputed Eq. (2). Its report, transcripts/001516/verifier-1-report.md, gave its own outcome for each claim; all 32 agree with the record. Its points on the descriptive section, answered in the revision, were: F0 included the dimmed frame 0 (B5), now left out, with the effect of keeping it printed; the field direction was taken from the response it then measures (B6), now taken for each set from the other pulse sets of its field of view (it moves by -0.4 to 0.7 degrees); the amplitude-to-field mapping cannot be checked (B7), unchanged and still flagged; and no overlay of the traces on the images was shown (not checked), now added for every measured cell. The overlay showed that touching pairs of cells in c2, c3 and c10, and a stacked pair and a cluster of dim cells in c11, had been measured as one cell each; touching cells are now split (which also adds a touching pair in c12) and objects that are not round are left out, which gives 29 cells in place of 30 and changed the descriptive numbers, none of which decides an outcome.
  • Round 2
    2026-11-02
    Agreed with 32 of 32 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full re-executed notebook after the round-1 revision, the helper module, the claims file and the record, with the paper. Its report, transcripts/001516/verifier-2-report.md, agrees with all 32 outcomes and checked every number in the conclusions, the summary, the README and the record against the printed outputs. Its points on text, none bearing on an outcome, were answered as follows. The summary (cell 29), the record's finding and the helper docstring said the first frame of every set is dimmer, where only the median was printed; cell 15 now prints the range over files and the count below 0.9 (0.52 to 1.11, 65 of 72), and the three texts say 65 of 72 files. Cell 10 listed touching pairs in c2, c3, c10 and c12 and cell 12 listed c11 too; in the overlay (cell 11) c11 cell 1 touches a cell that is left out, and cell 12 now says so. The finding of kind other gave the 12-point and 16-point falls as first against last 10 frames, now corrected. The fig5b response's by-eye reading of Fig. 5B is removed. The round-1 reasons' cell numbers are given with the current ones in brackets.

Attempt semenov-2026-03

  • Round 1
    2026-11-02
    Agreed with 29 of 31 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper. The verifier tested the helper functions on a synthetic cell, checked Eq. (2) and the units, and read the 220 session descriptions. Its report had no attempt record and gave its own outcome for each claim; it differs from the record on fig2a-fluovolt-saturation (not_reproduced) and fig3-dye-sensitivity (partially_reproduced), both now changed to its outcome. The revision also re-traced three cell outlines that the overlays it asked for showed to be wrong.
    • fig2a-fluovolt-saturation: the verifier’s outcome was “Not reproduced”. Cathodic dF at 360 V/cm is 49.4% (far), 78.5% (near) and 23.7% (none), against 66 +- 6.6. Anodic dF at 570 V/cm is in tolerance only with the near background (-88.6), and that reading fails the 1000-1400 condition. The not_reproduced outcomes rest on a background distance the paper does not give (problem 3).
    • fig3-dye-sensitivity: the verifier’s outcome was “Partially reproduced”. At 0.267 um the slopes 21.6 and 7.4 fail and Pearson 0.964 and 0.762 pass. At the pixel giving the paper's 8-um mean radius the slopes are 26.6 and 9.53, Pearson 0.976 and 0.831, all in tolerance. The slopes depend on a pixel size the files may not store; the correlations and the slope ratio (2.92 against 2.86) match either way.
  • Round 2
    2026-11-02
    Agreed with 31 of 31 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook with the conclusions and the summary, the attempt record, the README, the helper module and the claims file, with the paper. The verifier agreed with all 31 outcomes and found every assumption stated and reasonable, with qualifications on the volts mapping, the pixel size and the background distance. It quoted statements the numbers do not support in cells 0, 21, 47, 52, 75 and 81, the record (radius range, Pearson values) and the README (variant coverage, unqualified table entries); all are corrected. Outputs added: side fits without the 43 V/cm sets, measured against calculated IMP at 43 and 150 V/cm under every background band, and an outline variant on the outer membrane for the Di-8-ANEPPS cells. No outcome changes and none is proposed.

Attempt semenov-2026-04

  • Round 1
    2026-11-02
    Agreed with 21 of 30 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The first executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper. The verifier tested helper functions on a synthetic polarized cell and modelled the electrode field. Its report gave its own outcome for each claim; it agreed with 21 of 30. Its other points: the header still carried an outcome table (B10, now updated to the revised outcomes); background reading (b) sits about 120 counts above the camera offset (B7, a camera-offset reading is added: FluoVolt 17.3% and -25.2% at the claim's levels, between readings a and b); the responding-cell selection uses the cells' own response and the experiment reading averages 1 to 5 cells (B8, kept, the three cell readings are all shown); the pole values at all 19 sets are now printed as numbers.
    • fig1-pole-dimming: the verifier’s outcome was “Not reproduced”. Under top, condition 1 fails in all 6 readings: cathodic dF is higher at 780 than at 570 V/cm (e.g. 18.1 vs 13.0%, cell 50). Under bottom there is no 570 V/cm set. Di-8 cathodic dF rises through 90 to 250 V, so condition 1 also fails for any factor that puts 570 and 780 V/cm inside the data. The sets exist; what is missing is the V/cm factor, so the block reason would be metadata_insufficient, and under any physically plausible factor the sets reach 570 to 1400 V/cm (B2).
    • fig2b-di8-climbs-to-570: the verifier’s outcome was “Partially reproduced”. Under both factors, |dF| rises at every step on experiment and all-cells means. It fails for the centre cell, which is the closest reading to the paper's one cell per experiment. The 570 V/cm level exists only under top, and 43 V/cm exists only under bottom.
    • fig2b-di8-decline-within-set: the verifier’s outcome was “Reproduced”. Reproduced only if the factor is top-like. Under top the cathodic end is below the start in every set from 780 V/cm, under both start/end readings. The anodic pole does not decline, so reading (d) fails. Most of the cathodic drop is a drift shared by both poles: at 780 V/cm the shared offset drops about 1.9% while the polarization amplitude drops about 0.8%, and no low-field set was run as a control for drift (B6, C).
    • fig3-dye-sensitivity: the verifier’s outcome was “Blocked”. Blocked as metadata_insufficient. The slope scales directly with the volts-to-V/cm factor. That factor is not recorded, and the adopted value was chosen by matching these same slopes, so the test is circular. Correlation coefficients are within tolerance under bottom (FluoVolt 0.90 to 0.91, Di-8 0.80 to 0.82). Even with the fitted factor, no reading meets both slopes (0 of 32). Under physically plausible factors the slopes would be 3 to 4 times too low. The bottom factor also does not fit the electrode geometry, which gives about 4.6 to 7.2 V/cm per V for 1.6 mm (B1).
    • fig4b-di8-limits: the verifier’s outcome was “Not reproduced”. The largest Di-8 means over all 19 sets are 24.3% and -29.2%, against 57 +- 14 and -55 +- 4. This holds for every factor that includes 570 V/cm. Measured IMP is also already below IMPC at 43 to 360 V/cm.
    • fig4b-first-10-pulses: the verifier’s outcome was “Not reproduced”. The largest first-10 mean is 27.0%, against 66 +- 15, under any factor.
    • fig4b-cathodic-asymmetry: the verifier’s outcome was “Not reproduced”. Not reproduced only if the factor is top-like. Under top, cathodic dF rises from 780 to 1400 V/cm (18.1 to 24.3%) and is non-zero at 1400 V/cm (p < 0.001). Only the anodic -29.2% meets its target.
    • fig4c-equator-follows-cosine: the verifier’s outcome was “Not reproduced”. Not reproduced only if the factor is top-like. 9 to 12 of 12 arcs differ in every reading. Some differences do not depend on the factor: the cathode-side arcs near 90 degrees read about zero or negative where IMPC is positive.
    • fig7b-charging-during-pulse: the verifier’s outcome was “Not reproduced”. Not reproduced only if the factor is top-like. Best reading (anodic pole, experiment means): 1.46 at 560 V/cm passes, 1.62 at 780 V/cm fails against 2 +- 0.2, and 1000 to 1200 V/cm ratios are 1.72 to 1.77, not above 2. In the per-cell normalization for the mean-pole reading the 150 V/cm values are near zero, so the ratios become meaningless (-10.7, 16.9) (B9).
  • Round 2
    2026-11-03
    Agreed with 30 of 30 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook of the first revision, the helper module, the claims file and the attempt record, with the paper. The verifier agreed with all 30 outcomes and found no place where the claims file misreads the paper. It checked rod_field_per_volt against the line-charge solution and found the factor of 5.6 V/cm per V reasonable. It found statements the outputs do not support, all corrected: the baseline range in cell 38 and the fig2a-fluovolt-stable notes; the one-over-factor slopes in cell 26 and the fig3-dye-sensitivity notes; the round-1 count in this record (it agreed with 21 of 30, not 19); and the README's 17 minutes, which no output showed (the README now gives the 11 minutes of this run, the notebook comment 10 minutes for the load). It found every round-1 point resolved except the untested interval of factors between 1.72 and 2.0 for fig3-dye-sensitivity, now run on a fine grid, and asked for the bleaching offset to be described in fig7b-charging-during-pulse.

Attempt semenov-2026-05

  • Round 1
    2026-11-02
    Agreed with 26 of 27 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper. The verifier queried the archive API, rendered Fig. 6 of the paper, and tested the helper functions on synthetic stacks. Report in transcripts/001521/verifier-1-report.md. Its other points were also addressed: the docstring file counts are corrected (31 and 42), the conversion is now taken from Fig. 6B, and results with fields of view as the unit are added.
    • fig6b-650-weak-but-significant: the verifier’s outcome was “Not reproduced”. Both tests the statement names are fully specified, and both conversions fail at least one. Under M1 the count matches under one rule, but the end mean is -9.2%, significant in the wrong direction, and the single-tailed test against 230 V/cm gives p = 0.20; under M2 against zero p = 0.27.
  • Round 2
    2026-11-03
    Agreed with 27 of 27 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook with the conclusions and summary, the README and this record. Report in transcripts/001521/verifier-2-report.md. In reply to its section 2, the notebook and record now print and cite the p-values that were given as below a bound (4.9e-09 and 3.0e-11 against the sham), the README states the 12 to 16% decline as the background-corrected dF and the raw decline as 7.5 to 8.7%, the summary and data check say the decline is steepest in the first recording and has no steady trend later in the train session, the train result is qualified to the 10-frame window with the 5-frame case (27.9%, higher fields 76.6 and 82.1%) given, the guess about Fig. 5B is removed, the file count is corrected to 33 trains and 9 shams in the train session, and outputs were added for the subject age and species and for the six other dandisets that name the paper (archive metadata). In reply to its section 3, a background taken as the 10th percentile of the cell-free pixels, less affected by dim unsegmented cells, was added; it changes no outcome. No outcome changed and none is proposed.

Attempt semenov-2026-06

  • Round 1
    2026-11-02
    Agreed with 26 of 27 outcomes. Independent agent run by CatalystNeuro (verifier-1, run 41544331111; same harness, separate context, did not write the notebook). Reviewed: The handover of the author-answers run (commit 67659bd9), the executed notebook with the conclusions and summary removed, the helper module and the claims file. The verifier also checked the archive's asset list for the blocked claims, tested the helpers on synthetic images and read the paper.
    • fig7c-full-reseal-mild-residual-strong: the verifier’s outcome was “Partially reproduced”. The reseal and residual parts need only test-pulse data, which is in the dataset, and the notebook already contains the numbers. Reseal - 570 and 760 V/cm do not differ from control (unpaired p >= 0.17). Residual - test dF is below 100% at 1000, 1200 and 1400 V/cm at both poles. The criterion counts those two parts as a partial reproduction. The "no pole difference at the test pulse" part could also be tested (paired cathodic vs anodic normalized test dF) but was not run. The "cathodic more conductive during the pulse" part needs Fig. 4B data, which is missing.
  • Round 2
    2026-11-03
    Agreed with 27 of 27 outcomes. Independent agent run by CatalystNeuro (verifier-2, run 41550403379; same harness, separate context, did not write the notebook). Reviewed: The full executed notebook of the author-revise-1 run (commit 5846abf5), with its conclusions and summary, the helper module, the claims file, the attempt record and the README.

Attempt semenov-2026-07

  • Round 1
    2026-11-03
    Agreed with 29 of 30 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The handover of the first run, the executed notebook with the conclusions and summary removed, the helper module and the claims file, with the paper under paper/.
    • fig2cd-nonelectroporating-stable: the verifier’s outcome was “Partially reproduced”. The result depends on the background reading. With no subtraction (section 2.3 as written), 0 of 12 pre-exposure comparisons reach p<0.05 (smallest 0.057). With the annulus it is 1 of 12 (p=0.047), and with the background file 2 of 12. In every reading the cathodic 150 V/cm sets fall 26-39% below the first set (p 0.034-0.20), which does not look constant.
  • Round 2
    2026-11-03
    Agreed with 30 of 30 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The full executed notebook of the revision after round 1 (executed by the workflow), the helper module, the attempt record, the README and the claims file, with the paper under paper/.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

Provenance

Attempt record
semenov-2026-01
Paper
Sub-microsecond optical measurements of cell membrane charging and lesioning by pulsed electric fields
Date
2026-11-02
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001515 (on DANDI)
Version
0.261006.1841 (doi:10.48324/dandi.001515/0.261006.1841)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2026-02
Paper
Sub-microsecond optical measurements of cell membrane charging and lesioning by pulsed electric fields
Date
2026-11-02
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001516 (on DANDI)
Version
0.261006.1833 (doi:10.48324/dandi.001516/0.261006.1833)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2026-03
Paper
Sub-microsecond optical measurements of cell membrane charging and lesioning by pulsed electric fields
Date
2026-11-02
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001517 (on DANDI)
Version
0.261006.1856 (doi:10.48324/dandi.001517/0.261006.1856)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2026-04
Paper
Sub-microsecond optical measurements of cell membrane charging and lesioning by pulsed electric fields
Date
2026-11-02
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001518 (on DANDI)
Version
0.261006.1957 (doi:10.48324/dandi.001518/0.261006.1957)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2026-05
Paper
Sub-microsecond optical measurements of cell membrane charging and lesioning by pulsed electric fields
Date
2026-11-02
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001521 (on DANDI)
Version
0.261006.1845 (doi:10.48324/dandi.001521/0.261006.1845)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2026-06
Paper
Sub-microsecond optical measurements of cell membrane charging and lesioning by pulsed electric fields
Date
2026-11-02
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001525 (on DANDI)
Version
0.261006.1856 (doi:10.48324/dandi.001525/0.261006.1856)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13
Attempt record
semenov-2026-07
Paper
Sub-microsecond optical measurements of cell membrane charging and lesioning by pulsed electric fields
Date
2026-11-02
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001526 (on DANDI)
Version
0.261006.1851 (doi:10.48324/dandi.001526/0.261006.1851)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Other data and code used 1

What the attempts used that is not in the datasets: other data, and the paper’s code. Each is as the attempt’s record describes it.

  • 10.1016/j.bioelechem.2025.109143 DOI

    The charging time constant of Eq. (1), tau = 44.5 ns per um of cell radius (the linear fit through the origin of Fig. 5C), and the background method for the strobe images (ROIs near the poles outside the cell, section 2.4), from reference [20] of the paper, Semenov et al. 2025, Bioelectrochemistry 168, 109143 (PMC12553484).

    Source as recorded: doi:10.1016/j.bioelechem.2025.109143

Badges for this paper

Encore: 11 findings reproduced, Semenov et al. 2026

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/semenov-2026/"><img src="https://encorescience.org/badge/papers/semenov-2026.svg" alt="Encore: 11 findings reproduced, Semenov et al. 2026"></a>

Or as Markdown:

[![Encore: 11 findings reproduced, Semenov et al. 2026](https://encorescience.org/badge/papers/semenov-2026.svg)](https://encorescience.org/papers/semenov-2026/)

The same numbers are in this page’s JSON, under badge (how it is counted).