What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.
Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.
The claims file's header reads the dandiset's title and description as pointing at the two-pulse recovery experiment of Fig. 7 (Results 3.7), adds fig7a-cosine-profiles because "Fig. 7 is this dandiset's experiment", and plans collapsing 20 and 40 images as the only deviation. The files name FluoVolt with a FITC cube in all 72 sets, 1.00-mm electrodes, single pulses and pairs at 50 to 250 V (described as 0.15 to 1.57 kV/cm) and intervals of 1, 5, 25, 125 and 250 us, where Fig. 7 used Di-8-ANEPPS, 1.6-mm electrodes, conditioning at 150 to 1400 V/cm and a 5-us interval only. Should the header and the Fig. 7 claims (fig7a-cosine-profiles, fig7b-charging-during-pulse, fig7ab-test-pulse-recovery, fig7c-fast-conductivity-drop, fig7c-full-reseal-mild) say that the dandiset holds a FluoVolt two-pulse experiment the paper does not report, and that no claim can be tested on it?
Passage. Each conditioning pulse was followed in 5 us with a 1-us, 150 V/cm test pulse (Results 3.7); Cells loaded with Di-8-ANEPPS (Fig. 7 legend); two tungsten rods 1.6 mm apart (Methods 2.2); and Future studies should focus on the time course of membrane recovery, perhaps using the same two-pulse protocol as in Fig. 7, but varying the time interval between the pulses (Discussion).
Why it matters. The outcomes do not change. All five Fig. 7 claims are blocked as data_missing because the dye, field levels, electrode spacing and number of cells differ from the paper's, as the claims file's criteria name Di-8-ANEPPS and n = 5. If the reader kept the premise, a later attempt might be asked to test the Fig. 7 criteria on the dataset's FluoVolt 5-us pairs (c2, c9), which the notebook shows only as a variant.
No reader has answered it yet.
Should the criterion of fig2a-fluovolt-stable allow for the number of tests it makes? Each start/end reading runs 24 paired t-tests at p < 0.05 with n = 4 (6 pulse comparisons at 1000 to 1400 V/cm and 18 baseline comparisons), and the claim fails if any one of them is significant. With no change at all, the chance that at least one of 24 independent tests falls below 0.05 is about 70% (1 - 0.95^24), so the criterion fails a stable recording more often than not. A reading that corrects for the number of tests (for example Bonferroni or Holm over the 24), or that asks for a change larger than some size in % dF, would test what the paper says.
Passage. Without PEF (first 40 datapoints, or ~ 7 s in each set), measurements were stable, indicating no significant photosensitization or dye bleaching ... but the dye response in each set stayed stable through the 60 pulses applied (Results 3.2, paragraph 2); the Fig. 2 legend names a 2-tailed paired t-test. The paper reports no test for this statement and does not say how many comparisons it made.
Why it matters. Under the adopted far background the claim fails on 2 significant tests of 24 under reading (a) and 5 under reading (b), with changes of 2.5 to 7.0% dF against responses of 40 to 70%. Under reading (b) the smallest p is below 0.0005 (360 V/cm cathodic baseline, -4.2%) and the next is 0.002, so a Bonferroni correction over 24 tests (p < 0.0021) would leave one or two significant baseline changes; under reading (a) it would leave none (smallest p 0.005), so the readings would disagree and the claim would become blocked (methods_underspecified) under the criterion's own rule for disagreeing readings.
No reader has answered it yet.
The criterion judges the claim of absence by a one-sample t-test of each cell's end-of-recording dF against zero. Can that test stand for the paper's "not statistically significant", when the same claims file treats 1000 and 1200 V/cm as a clear entry? In this dataset that test finds no increase at 1000 and 1200 V/cm either, so it cannot detect the effect the claim says is absent at 780 V/cm. Should the test be the one that detects the entry at 1000 and 1200 V/cm (for example against the 0 V/cm group, or on the change at the pulse), with the claim of absence judged against that?
Passage. Exposure to a single 1-us pulse at escalating field strengths, from 0 to 1200 V/cm established a clear peak of Ca2+ entry at 1000 and 1200 V/cm, and Ca2+ signal remained elevated through the 5-min observation period (Fig. 6A). A subtle dF increase after exposure at 780 V/cm was at the detection limit and not statistically significant. (Section 3.6, paragraph 2; Methods 2.5 name Student's t-test and the one-sample t-test.)
Why it matters. Unpulsed cells decline to -12% by the end of the recording here, so the end value is below zero at 780, 1000 and 1200 V/cm (under 3.9 V/cm per V, -7.42, -5.44 and -3.83%) and the criterion's test gives "reproduced" without being able to find any increase. Against the 0 V/cm group the end value and the peak are significantly higher at 780 V/cm (p = 1.3e-06 and 0.021), which would give "not reproduced"; the step of dF at the pulse against the 0 V/cm group detects 1000 and 1200 V/cm (p = 0.025 and 3e-07) and not 780 V/cm (p = 0.10), which would give "reproduced". The verifier of round 1 reported the criterion's test as unable to detect an increase. The verifier of round 2 noted that the step reading is marginal at 1000 V/cm (p = 0.058 against zero) and that the steps at 780 and 1000 V/cm were not shown to differ; they do not (p = 0.40), so no reading here both detects 1000 V/cm clearly and finds 780 V/cm absent.
No reader has answered it yet.
The criterion makes the claim methods_underspecified when the paired and the unpaired two-sided t-test disagree. Does the paper not settle the reading? Results 3.7 reports the 360 V/cm cathodic test-pulse point, which reaches about 120% of control, as p > 0.1, and the Fig. 7B legend tests the difference "from the undamaged membrane (gray area between horizontal dashed lines)", a band with its own spread. Both fit an unpaired comparison with the control group more than a paired one. Should the criterion take the unpaired test as the paper's, with the paired test as a variant?
Passage. Also, an accidental ΔF peaking to 120% (p > 0.1, lower panel in Fig. 7B) was considered as 100% for interpolation. (Results 3.7, paragraph 6); * p < 0.05, ** p < 0.01 with a two-way t-test for the difference from the undamaged membrane (gray area between horizontal dashed lines). (Fig. 7B legend)
Why it matters. On the dataset the cathodic test response after 360 V/cm is 133% of control; the paired test gives p = 0.0038 and the unpaired p = 0.61. The paired test finds a difference in 16 of 18 variants and the unpaired test in none, so the claim is blocked under the criterion as written and would be reproduced (80.0% of control at 1000 V/cm, within 80 +- 8) under the unpaired reading. The same choice bears on fig7a-test-pulse-cosine-up-to-1000 and fig7b-test-pulse-reduced-1200-1400, which take their tests from this claim.
The reader’s answer. Changed. The paper settles the reading. The Fig. 7B legend tests "the difference from the undamaged membrane (gray area between horizontal dashed lines)", a comparison with the control group and its spread; the Methods name only "Student's t-test and one-sample t-test"; and the paper writes "paired" where it pairs ("2-tailed paired t-test", Fig. 2D legend) but not for Fig. 7B or in Results 3.7 ("two-sided t-test"). The criterion of fig7b-test-pulse-unchanged-to-760 now takes the unpaired two-sample two-sided t-test against the control group as the paper's test, shows the paired test and the one-sample test as variants, and drops the methods_underspecified rule. fig7b-test-pulse-reduced-1200-1400 now uses the same test, with only the pole readings left open, and fig7a-test-pulse-cosine-up-to-1000 refers to that test in place of its readings. Expected values and statements are unchanged.
The criterion allows the cathodic, anodic and mean-of-poles readings for the ~70% and ~50% test-pulse values. Results 3.7 paragraph 6 says one dF value, the cathodic pole at 1400 V/cm, was negative and was omitted from Fig. 7C. If that value is the test-pulse value of the lower panel of Fig. 7B, the paper's ~50% after 1400 V/cm cannot be a cathodic or a mean-of-poles value, and only the anodic reading can carry the 70% and 50%. Should the criterion keep only the anodic reading? Or is the omitted value the conditioning-pulse value of the top panel, so that the readings stand?
Passage. One ΔF value (cathodic pole at 1400 V/cm) was omitted because it was negative, perhaps being a measurement error due to dye bleaching. (Results 3.7, paragraph 6); Still more intense PEFs of 1200 and 1400 V/cm reduced charging by the test pulse to ~70% and ~ 50%, respectively (p < 0.05 and p < 0.01, two-sided t-test) (Results 3.7, paragraph 5)
Why it matters. Raised by the round-2 verifier. On the dataset, under the main reading, both reductions are significant at the cathodic pole (25.2% and -11.3% of control, unpaired p 0.022 and 0.0010) and for the mean of poles (53.4% and 27.2%, p 0.0013 and 0.0002), with values outside tolerance, which the criterion calls partially reproduced. The anodic pole is within tolerance (68.7% and 48.0%) but p 0.086 and 0.011, short of p < 0.05 and p < 0.01, so under the anodic reading alone the claim would be not reproduced. The anodic reading meets the whole criterion in none of 22 variants.
No reader has answered it yet.
The criterion tests "no difference between the poles was detected by the test pulse" at every strength, 1400 V/cm included. The paper's sentence refers to Fig. 7C, which leaves out the negative cathodic dF at 1400 V/cm. Should the pole comparison at the test pulse cover only the strengths Fig. 7C shows (360 to 1200 V/cm at the cathodic pole)?
Passage. One ΔF value (cathodic pole at 1400 V/cm) was omitted because it was negative (Results 3.7, paragraph 6); Fig. 7C shows a profound reduction in the λm,eff ... While the cathodic pole became more conductive than the anodic pole during the electroporating pulse (Fig. 7B, see also Figs. 1 and 4B–D), no difference between the poles was detected by the test pulse. (Results 3.7, paragraph 7)
Why it matters. Raised by the round-2 verifier. On the dataset the paired test finds a pole difference after 1400 V/cm (cathodic minus anodic -59.3 points of control, p 0.0002) and none at 360 to 1200 V/cm (smallest p 0.12; in 21 of 22 variants). The part fails as the criterion is written and holds with 1400 V/cm left out. The outcome, partially reproduced, rests on the reseal and residual parts and does not change either way.
No reader has answered it yet.
The Fig. 2 legend gives the reduction as "small (≤20%)", the text of section 3.2 as "about 20%", and the claim's statement repeats both, while the criterion's tolerance is 20 +- 2%, symmetric about 20. Should a reduction below 18% (for example 10 to 18%, which the legend's "≤20%" allows) count as within the expected value, that is, should the tolerance be one-sided (0 to 22%, or up to 20%)?
Passage. Note the lack of changes until electroporation by a 1000 V/cm PEF and a small (≤20%) but persistent reduction of ΔF after it. (Fig. 2 legend); ΔF values averaged across each set of 60 PEFs stayed nearly constant before the electroporation, but dropped by about 20% in the sets acquired after it (Fig. 2D, p < 0.05). (Results, section 3.2)
Why it matters. Raised by the round-1 verifier. In this attempt every set reduction with p < 0.05 is above 22% (26.0% or more for both poles averaged), and the anodic pole's mean reductions below 18% (12.5 to 17.5% across readings) come either with no set at p < 0.05 or with a pre-exposure set that differs, so a one-sided tolerance would not change the outcome here. A later attempt with other cells could fall in that range.
No reader has answered it yet.