Papers / Xia et al. 2021

Xia et al. 2021

Imaging in vivo acetylcholine release in the peripheral nervous system with a fluorescent nanosensor

Outcomes of 29 claims

  • 4 reproduced
  • 4 partially reproduced
  • 3 not reproduced
  • 18 blocked

Summary: Of the paper's main in vivo findings, the vesamicol block of the nanosensor signal and its rostral to caudal spread across the ganglion held up in part, each in the one experiment or mouse deposited; the spread's timings did not match. The ex vivo Michaelis-Menten calibration and the size of the evoked response did not reproduce: the deposited recordings rise by 17.1 to 40.1% where the paper reports 3.7%, and no file records when stimulation began or ACh was added. The control nanosensor tests ruling out pH effects, and the voltage and pulse dose responses, are untestable, as those recordings are not deposited. The sensor's gel bands and receptor staining reproduced, and its placement on somata in part.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Xia et al. (2021) from SPARC:108 and SPARC:75 12 Open in Colab

Reproduced4

  • Reproduced

    In native PAGE the purified nanosensor runs as several bands of lower mobility than the DNA scaffold (likely 1 to 4 AChE per scaffold), and these bands carry both pHAb and AF647 fluorescence.

    Ethidium image, lane 3 (main peak) has two bands (rows 511 and 593) between the well and the scaffold band of…

    Results, Fabrication and in vitro characterization, paragraph 2 (beginning "Fully assembled ACh nanosensors were purified"); Figure 2E; Figure S2Cfig2e-page-bands
    From the paper

    several bands with lower mo-bility were identified likely due to variable numbers of AChE (from 1 to 4) conjugated to the DNA scaffold (Fig. 2E). Bands that presumptively contain ACh nanosensors displayed overlapping fluorescence of pHAb and AF647

    Result

    Ethidium image, lane 3 (main peak) has two bands (rows 511 and 593) between the well and the scaffold band of lane 1 (row 878). In the registered pHAb and AF647 images lane 3 has pHAb bands at rows 783 and 861, above the pHAb-labelled scaffold band of lane 1 (row 1119), and AF647 bands at rows 783 and 859, 8 and 10 SD above the gel between lanes. Lane 1 of the fluorescence images has a single pHAb band and no AF647 band above background, as for a scaffold without BTX, which fits Figure 2E's label of lane 1 and not Figure S2C's.

    Deviations from the paper’s method
    • Lanes found as runs of columns with signal and bands as lane-profile peaks with a prominence of at least 5% of the profile range, choices made here as the paper gives no quantification. The ethidium image is framed differently from the fluorescence pair, so band positions are compared within each.
  • Reproduced

    Ex vivo staining of freshly isolated SMG with BTX-AF647 shows a punctate pattern across the ganglion, confirming nicotinic ACh receptors on SMG neurons.

    Judged by eye on the maximum projections and brightest planes of the two BTX stacks of SPARC:75 (GFP and AF647…

    Results, ACh nanosensors in SMG, paragraph 1; Figure S5figs5-btx-staining
    From the paper

    Ex vivo staining of freshly isolated SMG with BTX-AF647 showed the expected punctate staining pattern across the ganglion, confirming expres-sion of nicotinic ACh receptors in SMG neurons

    Result

    Judged by eye on the maximum projections and brightest planes of the two BTX stacks of SPARC:75 (GFP and AF647 by the dye names in the LSM metadata). AF647 puncta cover every tile over the GFP mask in all four images (5/5 to 29/29 with the Otsu mask), at 4.4 to 15.8 puncta per 100 um^2 with the background rule used since round 1 (17.8 to 64.4 with the first rule, which passed much of the noise), and lie along the borders of the somata. Nearness to GFP beyond chance holds in three of the four images by at least one mask (low-magnification projection 0.82 of puncta within 1 um of the Otsu GFP mask against 0.37 of the field; its brightest plane 0.61 against 0.24 with the background-rule mask; high-magnification projection 0.18 against 0.15), and not in the brightest high-magnification plane (0.10 against 0.11). The high-magnification stack holds data in 12 of its 62 planes.

    Deviations from the paper’s method
    • Puncta defined as components above the median + 3 SD of the lower half of the pixels reflected about the median, 0.1 to 25 um^2, and the GFP mask by Otsu's threshold or the same background rule; the first rule (mean + 3 SD of the below-median pixels) is shown as a variant. The paper gives no quantification, and these support, not replace, the judgement by eye the criterion asks for.
  • Reproduced

    All evoked nanosensor responses in Figure 7A climb to their peak around 10 to 15 s after stimulation onset, as in Figure 5B to E.

    sub-3, with the four regions and block onsets of fig7-rostral-caudal in place of AQuA's events.

    Results, ACh nanosensor response reflects physiological ACh propagation, paragraph 1; Figure 7Averifier disagreed at firstrests on an assumptionquestion to the readerfig7-peak-timing
    From the paper

    All evoked nanosensor responses in Fig. 7A climbed to the peak around ∼10 to 15 s, an observation consistent with Fig. 5 B–E.

    Result

    sub-3, with the four regions and block onsets of fig7-rostral-caudal in place of AQuA's events. Counted from each region's onset (reading ii), the regions peak 11.8 to 18.1 s later; all four are within 9 to 16.5 s in 30 of 36 variants, all those with the bleaching curve fit outside the response on both clocks and the whole-trace fit on the 0.50 s clock. The main variant gives 14.30, 14.85, 15.40 and 13.48 s, and 126 of 157 blocks peak 9 to 16.5 s after their own onset (median 13.8 s). Counted from stimulation onset (reading i) the regions peak 18.0 to 26.4 s after it and no block peaks within 16.5 s of it. The pass is weak: it rests on region onsets that come 2.75 to 3.3 s after the paper's for the rostral region (none of the six times of fig7-rostral-caudal matches), and reading (ii) does not fit the paper's own times, by which the rostral region peaks 8.80 s and the most caudal 29.15 s after their onsets, while reading (i) gives 11.55 s for the rostral region. The claims file flags the paper's contradiction only for the most caudal region; whether reading (ii) should stand is asked of a reader (questions/xia-2021.yaml). Reproduced under reading (ii), which the claims file as written allows.

    Deviations from the paper’s method
    • AQuA (Wang et al. 2019, the paper's ref. 32; Methods, AQuA Analysis) is MATLAB software that cannot be installed in the entry's locked Python environment, and its parameters are not given. Assumed in its place: the onset and peak of 16 x 16 pixel blocks of the pHAb tissue mask (`block_onsets`; onset the first frame from frame 19 that begins 3 frames above the pre-onset mean + 3 SD of the photobleaching-corrected dF/F, peak the largest 3-frame mean), with 32 pixel blocks, 2 and 5 SD and three photobleaching fits as variants. Block onsets measure where and when the signal rises, as AQuA's events do, but AQuA's events and times may differ.
    • The paper's four AQuA areas cannot be located from its text. Regions drawn here from the axis of Figure 7B (rostral up, caudal down, lateral to the left, as the criterion says; the files carry no orientation, and the frame is taken as shown in Fig. 7A) are the rostral, middle and caudal thirds of the tissue's extent along the rows and, for the lateral region, the blocks of the lower two thirds in the quarter of columns furthest to the left; a region's onset and peak are the medians over its blocks.
    • Stimulation onset taken as 10.45 s, frame 19 on the paper's 0.55 s clock, from Fig. 6A ("Sti starts 10.45 s") and Fig. 7A ("Stim starts 10.45 s"); the files do not record it. The responses start 4 to 13 frames after it in sub-2, sub-3 and sub-6.
    • Assumed that the deposited frames are oriented as Figure 7A shows them, rostral up and lateral to the left; the files carry no orientation, they are the camera's frames, the paper shows no sign of a flip, and the criterion reads the axis from Figure 7B. A comparison of the panels of Fig. 7A with sub-3, made outside the notebook as the entry reads no figures, agreed, but it is not part of the test. The direction of propagation rests on this assumption: every other orientation is run; flipped top to bottom or turned 180 degrees, the rostral region starts first in no variant, and flipped left to right the lateral region is no longer last at 8 V.
  • Reproduced

    The AF647 channel recorded with the pHAb signal of Figure 7 shows no visible fluorescence increase during stimulation, so the internal standard does not respond.

    sub-3, the 8 V recording of Figure 7. Under six readings (two bleaching fits, three ROIs) the AF647 half rises…

    Methods, Animal preparation and imaging; Figure S16rests on an assumptionfigs16-af647-stable
    From the paper

    SI Appendix, Fig. S16 exhibited a panel of time-lapse images from AF647 channel which were simultaneously recorded with the pHAb fluorescence in Fig. 7 and confirmed that there was no visible fluorescent increase during recording in AF647 channel.

    Result

    sub-3, the 8 V recording of Figure 7. Under six readings (two bleaching fits, three ROIs) the AF647 half rises by at most 0.4 to 3.7% after onset, within its pre-stimulus mean plus 3 SD (1.9 to 4.1%), while the pHAb half rises by 46.9 to 54.0%, 14 to 135 times more. The AF647 channel drops by 13 to 15% after stimulation and rises by 11.1 to 16.5% from that minimum; after it, the trace passes its pre-stimulus mean in 3 of 6 readings (by 1.35 to 2.77%, all with the bleaching curve fit outside the response) and its pre-stimulus mean + 3 SD in none.

    Deviations from the paper’s method
    • Assumed that the left half of the W-VIEW GEMINI frame is AF647 and the right half pHAb; the files carry no channel labels, and the right half is the one that rises. The test then shows that one channel stays flat while the other rises.
    • Whole SMG read as each channel's tissue mask, the whole half-frame, and the pHAb tissue mask applied to the AF647 half; onset as in fig5b (frame 19).

Partially reproduced4

  • Partially reproduced

    In size-exclusion HPLC the assembled nanosensors elute first (main peak near 7.5 mL), followed by a second peak at 9.1 to 9.2 mL of unreacted material, and the nanosensors are about 77% of the reaction mixture by area under all peaks of the pHAb channel.

    The pHAb chromatogram (HPLC_PHAB.csv) has two detectable peaks, at 15.16 and 18.05 min.

    Results, Fabrication and in vitro characterization, paragraph 2 (beginning "Fully assembled ACh nanosensors were purified"); Figure 2Drests on an assumptionfig2d-hplc-yield
    From the paper

    ACh nanosensors represent ∼77% of the reaction mixture based on the integration of areas under all detectable peaks from the pHAb channel chromatogram

    Result

    The pHAb chromatogram (HPLC_PHAB.csv) has two detectable peaks, at 15.16 and 18.05 min. The share of the first peak depends on the reading. With a flat baseline (reading a) it is 65.8 to 68.2% under every end of the second peak, below the tolerance of 69.3 to 84.7%, and with a common line under both peaks and a drop at the valley 66.2 to 69.1%. With a line under each peak (reading b, as the criterion writes it) it is 77.5 to 83.1%, within tolerance, when the second peak ends where its own descent ends (20.53 min) or where it falls below 2% of its height (20.94 min); when it ends where the signal returns to the pre-injection level (29.76 min) the second area is negative and no share can be read. 4 of 18 readings are within tolerance. The valley between the peaks is 5.19 high (main peak 13.62), so the line under each peak cuts through both peaks; it keeps 54% of the main peak's area above the flat baseline and 30% (end ii) or 23% (end iii) of the second peak's. Every reading that splits the overlap the usual way (flat baseline, or a common line with a drop at the valley) gives 65.8 to 69.1%, just below tolerance, so the share holds by the letter of reading (b) only. The retention volumes are not tested, as the paper gives no flow rate; the ratio of the retention times, 1.191, is 1.8% below the paper's 1.213 to 1.227. Partially reproduced, as the share holds under one reading of the criterion and the volume part cannot be tested. Measured is the share under reading (b), the second peak ending at the end of its descent, 1% detection rule.

    Deviations from the paper’s method
    • The paper gives no flow rate (Methods name the Superdex 200 increase 10/300 GL column and the Agilent Infinity 1260 HPLC only), and the files give time, so the main and second peak volumes are not tested. The first version assumed 0.5 mL/min, chosen because it put the peaks at the paper's volumes, which made that test circular.
    • "Detectable" peaks taken as those with a prominence of at least 1% of the largest (0.5% as a variant), a choice made here.
    • Assumed that the second peak ends where its own descent ends (slope below 1% of the steepest, 20.53 min), the usual limit of a peak; ends where it falls below 2% of its height and where the signal returns to the pre-injection level + 3 SD (29.76 min, the first version) are shown. The share under reading (b) depends on it.
  • Partially reproduced

    Confocal imaging of a nanosensor-stained SMG shows punctate AF647 and pHAb staining that overlaps and lies mainly on the neuronal cell soma, consistent with the BTX staining.

    SPARC:108 sub-5 (CZI; AF647, pHAb as AF532, EGFP; 27 planes, 17.41 um, as the Methods state) and the three…

    Results, ACh nanosensors in SMG, paragraph 2; Figure 3Drests on an assumptionfig3d-sensor-on-soma
    From the paper

    Confocal microscopy further confirmed that the punctate staining pattern of AF647 and pHAb were primarily localized on the neuronal cell soma (Fig. 3D).

    Result

    SPARC:108 sub-5 (CZI; AF647, pHAb as AF532, EGFP; 27 planes, 17.41 um, as the Methods state) and the three nanosensor images of SPARC:75. By eye (merges and a full-resolution crop with each channel alone), puncta appear in both channels with yellow spots where they coincide, but much AF647 lines cell borders and the ganglion capsule, and the coinciding spots lie mostly between or at the edges of the somata. With the background rule used since round 1, which marks 7 to 12% of the field as pHAb in four of five images (35% in sub-5 plane 13), 59 to 85% of AF647 puncta overlap pHAb in those four, against 39 to 53% with the pHAb mask shifted by 5 um (top-hat pHAb 68 to 79% against 40 to 64%); in plane 13, 98% against 95%. The first rule marked 32 to 48% of the field and gave 84 to 98% against 78 to 98%. 9 to 47% of AF647 puncta lie in an Otsu soma mask covering 23 to 42% of the field, and 15 to 52% of the coinciding puncta lie within 1 um of it, against 27 to 48% of the field. Reading (b) fails in every image (0.09 to 0.35; 0.13 to 0.40 with a top-hat pHAb and a 1 um margin). In sub-5 the pHAb channel correlates with GFP (r 0.43 and 0.53), a sign of GFP bleed-through at 514 nm. Partially reproduced, as the puncta coincide beyond chance but their place on the somata is not shown.

    Deviations from the paper’s method
    • Assumed that the by-eye reading (a) is judged together with chance references, a 5 um shift of the pHAb mask and the share of the field covered by the soma mask, as the paper gives no colocalisation measure; the shift, the punctum size limits (0.1 to 25 um^2) and the soma masks (Otsu, background rule, 1 um margin) are choices made here.
    • The background of the claims file's mean + 3 SD threshold is not defined in the paper. Since round 1 it is the lower half of the pixels reflected about the median (threshold median + 3 SD), the usual half-Gaussian estimate; the first rule, mean + 3 SD of the below-median pixels, sets the threshold about 1 SD above the centre of a Gaussian and marked a third or more of the field, and is shown as a variant.
    • SPARC:75's nanosensor images are single planes and are used with the sub-5 stack.
  • Partially reproduced

    Vesamicol cuts the nanosensor response to 3 V stimulation; in the example the response with the drug is 17% of that after washout, and over four experiments the reduction averages 76.59 ± 11.34%, significant in each by a paired t test (P < 0.01).

    One experiment of four is deposited (sub-6, with drug then after washout, one field).

    Results, In vivo imaging of ACh release, paragraph 3; Figure 6A to Crests on an assumptionfig6-vesamicol
    From the paper

    Four independent inhibitor treatments affirmed that vesamicol can considerably suppress ACh nanosensors' readout by an average of 76.59 ± 11.34% (Fig. 6C)

    Reported statistics
    • paired t test, vesamicol treated against untreated, p < 0.01 (n = four independent inhibitor experiments)
    Result

    One experiment of four is deposited (sub-6, with drug then after washout, one field). Over 48 readings the peak with vesamicol is 11.3 to 29.9% of the washout peak, a reduction of 70.1 to 88.7%, within 76.59 +- 11.34% in 44. The paired t test over matched frames (reading b) gives p of 4.9e-11 or less in every reading, but the frames are not independent; over the means of twelve 10 s bins it gives p of 2.2e-06 to 0.14, below 0.01 in 37 of 48, and 0.0103 under the first reading. The example's 17% is matched in 24 of 48 readings (tissue 17.5 to 22.3% with the mean baseline, whole frame 13.0 to 17.0%, tissue without saturating pixels 11.3 to 17.6%), and in none of 13 cell-sized blocks (median 36.8%). 69% of the tissue pixels of the washout recording saturate at some frame. The mean over four experiments and test (a) over them cannot be computed. Partially reproduced, as the suppression holds in the one experiment, but three of four are not deposited and the example ratio depends on the ROI. Measured values are this experiment's reduction and ratio under the first reading (tissue, mean baseline).

    Deviations from the paper’s method
    • One experiment of four; the reduction is that of this experiment, not a mean over four.
    • Assumed that sub-6 is the example of Figure 6A and 6B (it is the only one deposited).
    • The ROI of Figure 6A is not given; tissue, whole frame, tissue without saturating pixels and 40 x 40 blocks were run. Peak taken from onset to 120 s after it, the end of the response by the paper's "within 2 min".
    • Stimulation onset taken as 10.45 s, frame 19 on the paper's 0.55 s clock, from Fig. 6A ("Sti starts 10.45 s") and Fig. 7A ("Stim starts 10.45 s"); the files do not record it. The responses start 4 to 13 frames after it in sub-2, sub-3 and sub-6.
    • Photobleaching correction by a monoexponential curve, each value divided by the curve (Methods, Animal Preparation and Imaging); the frames it is fit to are open, and both readings of the claims file (frames outside the response, whole trace) were run.
    • A 3-frame median filter is shown as a variant, for two single low frames in each recording.
    • The within-experiment paired t test is also run on the means of non-overlapping 10 s bins, as consecutive frames are not independent.
  • Partially reproduced

    At 8 V, AQuA shows the nanosensor signal spreading from rostral to caudal across the SMG. The rostral-most region rises at 13.20 s (2.75 s after stimulation onset) and peaks at 22.0 s; the signal reaches caudal regions by 13.75 and 15.40 s and lateral at 15.95 s; the most caudal region peaks at 44.55 s.

    sub-3, the 8 V recording of Figure 7, with block onsets in place of AQuA.

    Results, ACh nanosensor response reflects physiological ACh propagation, paragraph 1; Figure 7A and 7B; Figure S11verifier disagreed at firstrests on an assumptionfig7-rostral-caudal
    From the paper

    The spatiotemporal AQuA analysis of nanosensor response following 8 V stimulation across the SMG validated our prediction (Fig. 7A and Movie S3). The rostral-most region started to increase fluorescence at 13.20 and 2.75 s after the start of 10 s stimulation and peaked at t = 22.0 s

    Result

    sub-3, the 8 V recording of Figure 7, with block onsets in place of AQuA. The signal starts rostrally and spreads caudally and then laterally: in all 18 variants the median onset of the rostral third precedes those of the middle and caudal thirds, which precede the lateral region (frames 30, 34, 37 and 42 in the main variant), and block onset rises with the rostro-caudal position (Spearman rho 0.62 to 0.68, p 0.00011 or less). The times do not match. On the paper's clock the region onsets are 15.95 to 16.50, 17.60 to 19.25, 19.80 to 20.90 and 22.00 to 23.65 s, against 13.20, 13.75, 15.40 and 15.95 s; the rostral peak is 30.25 to 34.10 s against 22.0 s and the caudal peak 35.75 to 36.30 s against 44.55 s; none of the six times is within tolerance in any of the 36 variant and clock pairs. The direction rests on the orientation of the frame, which the files do not record: with the frame flipped top to bottom, flipped left to right or turned 180 degrees, the order holds in 0 of 18 variants (flipped left to right the rostral region still starts first in all 18, but the lateral region is no longer last). Part of the delay may come from the drop of both channels right after stimulation, which a threshold has to clear. Partially reproduced, as the criterion says when the order holds but the times do not, on the frame as deposited. Measured are the main variant's region 1 to 4 onsets, rostral peak and caudal peak (16 px blocks, 3 SD, fit a, 0.55 s clock).

    Deviations from the paper’s method
    • AQuA (Wang et al. 2019, the paper's ref. 32; Methods, AQuA Analysis) is MATLAB software that cannot be installed in the entry's locked Python environment, and its parameters are not given. Assumed in its place: the onset and peak of 16 x 16 pixel blocks of the pHAb tissue mask (`block_onsets`; onset the first frame from frame 19 that begins 3 frames above the pre-onset mean + 3 SD of the photobleaching-corrected dF/F, peak the largest 3-frame mean), with 32 pixel blocks, 2 and 5 SD and three photobleaching fits as variants. Block onsets measure where and when the signal rises, as AQuA's events do, but AQuA's events and times may differ.
    • The paper's four AQuA areas cannot be located from its text. Regions drawn here from the axis of Figure 7B (rostral up, caudal down, lateral to the left, as the criterion says; the files carry no orientation, and the frame is taken as shown in Fig. 7A) are the rostral, middle and caudal thirds of the tissue's extent along the rows and, for the lateral region, the blocks of the lower two thirds in the quarter of columns furthest to the left; a region's onset and peak are the medians over its blocks.
    • Stimulation onset taken as 10.45 s, frame 19 on the paper's 0.55 s clock, from Fig. 6A ("Sti starts 10.45 s") and Fig. 7A ("Stim starts 10.45 s"); the files do not record it. The responses start 4 to 13 frames after it in sub-2, sub-3 and sub-6.
    • Times are frame x 0.55 s, the paper's clock; the 0.50 s of the files is shown.
    • Assumed that the deposited frames are oriented as Figure 7A shows them, rostral up and lateral to the left; the files carry no orientation, they are the camera's frames, the paper shows no sign of a flip, and the criterion reads the axis from Figure 7B. A comparison of the panels of Fig. 7A with sub-3, made outside the notebook as the entry reads no figures, agreed, but it is not part of the test. The direction of propagation rests on this assumption: every other orientation is run; flipped top to bottom or turned 180 degrees, the rostral region starts first in no variant, and flipped left to right the lateral region is no longer last at 8 V.

Not reproduced3

  • Not reproduced

    The initial rate of the ex vivo nanosensor response follows a Michaelis-Menten curve in ACh concentration with EC50 (Km) 49.24 ± 5.84 uM and Vmax 281.00 ± 7.14 %/s (R2 0.9811); the upper limit of detection is 358.01 uM.

    One mouse (sub-1) of the paper's three, 8 concentrations from 0.000714 to 714 uM.

    Results, Ex vivo calibration of the ACh nanosensors, paragraph 2; Figure 4B legendrests on an assumptionfig4b-michaelis-menten
    From the paper

    the half-maximum response (EC50) to ACh was 49.24 ± 5.84 μM and upper limit of detection was 358.01 μM

    Result

    One mouse (sub-1) of the paper's three, 8 concentrations from 0.000714 to 714 uM. Over 80 readings (ROI tissue or whole frame, 0.55 or 0.50 s frames, two photobleaching fits, two baselines, five rate windows) Km is 0.031 to 0.73 uM and Vmax 8.3 to 49.7 %/s, none within tolerance (49.24 +- 5.84 uM, 281.00 +- 7.14 %/s); R2 0.01 to 0.73. The first reading gives rates of 0.3 to 16.3 %/s with no steady rise in concentration (Spearman rho 0.54, p 0.168), with one-frame steps of 23.1% at 0.000714 uM, 19.8% at 0.714 uM, 41.9% at 7.14 uM and 38.4% at 714 uM, none at 0.00714 and 0.0714 uM. In the six recordings with a step the signal drifts down by 1.5 to 15.5% before it, then jumps within one frame and stays high, so the steps may come in part from adding the solution; the files cannot tell. With one onset (frame 7) for every recording, Km is 0.545 uM and Vmax 11.4 %/s. Upper limit of detection of the first fit 1.92 uM (88% of Vmax) or 0.96 uM (tangent within 5%); the paper's constants give 361.1 and 181.3 uM by the same rules. Measured values are the first reading's Km, Vmax, R2 and reading (a) of the upper limit.

    Deviations from the paper’s method
    • One of three mice and 8 of the paper's concentrations (to 714 uM, not 7.14 mM) are deposited; means over mice and all points are the same here.
    • Assumed that ACh was added just before the largest one-frame rise of each recording, as the addition time is not recorded; at 0.00714 and 0.0714 uM there is no clear step, so this onset is noise there.
    • The ROI is not given; the stained tissue (Otsu mask of the first frame) and the whole frame were run.
    • Frame interval run at 0.55 s (Results, Ex vivo calibration, "0.55 s, the minimum sampling time") and at 0.50 s, the interval the per-frame timestamps of sub-2 and sub-3 record.
    • Photobleaching correction by a monoexponential curve, each value divided by the curve (Methods, Animal Preparation and Imaging); the frames it is fit to are open, and both readings of the claims file (frames outside the response, whole trace) were run.
    • Rate reading (a) fits from the last frame before the response to the peak, so that a rise within one frame is included; reading (b) over the first 2 to 5 frames.
  • Not reproduced

    The lower limit of detection is 228 nM, where two regression lines through the low-concentration data (0.71 nM to 14.28 uM) cross; the theoretical response there from the Michaelis-Menten equation (1.3 %/s, 0.72% per 0.55 s frame) is 8.18 times the background noise of 0.088 ± 0.039%.

    Five deposited concentrations up to 14.28 uM (0.000714 to 7.14 uM).

    Results, Ex vivo calibration of the ACh nanosensors, paragraph 2; Figure 4B(ii) legend; Methods, Ex vivo ACh calibrationrests on an assumptionfig4b-lod
    From the paper

    experimental data in the lower con-centration range (i.e., 0.71 nM to 14.28 μM) was grouped into two linear regions with the two regression lines crossing at a value of [ACh] = 228 nM

    Result

    Five deposited concentrations up to 14.28 uM (0.000714 to 7.14 uM). None of 160 crossings (80 rate readings by linear and log concentration) is within 205.2 to 250.8 nM; medians -140 nM (linear) and 3.11 nM (log); the first reading gives 0.977 nM. Baseline noise 1.77 +- 2.34% by SD and 1.17 +- 0.95% by frame-to-frame change, against the paper's 0.088%. The paper's own response at 228 nM (0.712% per 0.55 s) would have a signal-to-noise ratio of 0.40 or 0.61 at this noise; the fit of this mouse gives 0.01 to 0.02. Measured are the first reading's crossing (nM), noise (a) and signal-to-noise (a).

    Deviations from the paper’s method
    • Reading (c), the split of Figure 4B(ii), was not run, as it needs the figure's lines and the entry reads no figures.
    • Rests on the rates and onset assumption of fig4b-michaelis-menten, one mouse of three.
  • Not reproduced

    In vivo, lingual nerve stimulation (3 V, 10 Hz, 10 ms, 100 pulses) raises nanosensor fluorescence by 3.7% by 15 s with initial rate 0.294 ± 0.116 %/s, recovering to baseline within 2 min (three mice).

    Two 3 V, 100-pulse recordings of the ACh nanosensor are deposited, sub-2 and sub-6 after washout; which…

    Results, In vivo imaging of ACh release, paragraph 1; Figure 5Brests on an assumptionfig5b-in-vivo-response
    From the paper

    Upon the stimulation of the lingual nerve, fluorescence intensity increased 3.7% by 15 s with initial velocity of Vsensor = 0.294 ± 0.116%/s, which slowly recovered to baseline within 2 min (Fig. 5B).

    Result

    Two 3 V, 100-pulse recordings of the ACh nanosensor are deposited, sub-2 and sub-6 after washout; which recordings form the three mice of Figure 5B is not stated. Under 144 readings (frame interval, three bleaching fits, baseline, four ROIs including the tissue less the camera's dark level, recording or their mean) the dF/F 15 s after onset is 17.1 to 40.1%, none within 3.33 to 4.07%; the rate to the peak is 1.54 to 3.33 %/s, and the rates over 2 to 5 frames from the frame where each trace leaves baseline (frames 25 to 29) -0.81 to 4.20 %/s, none within 0.294 +- 0.116 %/s. Rates over 2 to 5 frames from frame 19 fall within it in 54 readings, but they cover baseline frames before the response and are not counted. Cell-sized 40 x 40 pixel blocks give 11.3 to 53.6% (sub-2) and 0.3 to 28.4% (sub-6); one of the 13 sub-6 blocks is within tolerance in both. At 120 s sub-2 is still 9.4 to 16.4% above baseline. Subtracting the dark level raises dF/F slightly (mean of both, tissue, 20.8 to 23.2% without and 21.9 to 24.4% with). Measured values are the mean of the two recordings under the first reading (0.50 s, bleaching fit outside the response, mean baseline, tissue ROI).

    Deviations from the paper’s method
    • Assumed that the deposited 3 V recordings stand for the three mice of Figure 5B; the deposit does not identify them, and sub-2 is the 3 V recording of the AQuA mouse.
    • The ROI is a hand-drawn ganglion cell in the paper (Fig. 5B legend) with no coordinates; tissue, whole frame, tissue without saturating pixels, tissue less the camera's dark level and 40 x 40 pixel blocks were run.
    • Stimulation onset taken as 10.45 s, frame 19 on the paper's 0.55 s clock, from Fig. 6A ("Sti starts 10.45 s") and Fig. 7A ("Stim starts 10.45 s"); the files do not record it. The responses start 4 to 13 frames after it in sub-2, sub-3 and sub-6.
    • Frame interval run at 0.55 s (Results, Ex vivo calibration, "0.55 s, the minimum sampling time") and at 0.50 s, the interval the per-frame timestamps of sub-2 and sub-3 record.
    • Photobleaching correction by a monoexponential curve, each value divided by the curve (Methods, Animal Preparation and Imaging); the frames it is fit to are open, and the frames before onset with those from 120 s or from 180 s after it, and the whole trace, were run.
    • Initial rate over k frames counted from the last frame before the trace leaves baseline (|z| > 5), as the responses start 6 to 10 frames after the assumed stimulation onset; the rates from frame 19 are shown and not counted.
    • Channel taken as pHAb is the right half in sub-2 (the half that rises), the single channel in sub-6.

Blocked1

  • Blocked

    At 3 V, in three independent experiments, AQuA shows the same rostral-to-caudal direction of propagation, with lower amplitude than at 8 V.

    Only the mouse stimulated at 3 and 8 V is deposited (sub-2 and sub-3, one ganglion); the two mice stimulated…

    Data missing from the datasetResults, ACh nanosensor response reflects physiological ACh propagation, paragraph 1; Figure S12; Methods, AQuA analysisverifier disagreed at firstfigs12-3v-propagation
    From the paper

    We also conducted the same analysis with a lower stimulation voltage of 3 V for three independent experiments and observed similar rostral-to-caudal propagation directionality

    Result

    Only the mouse stimulated at 3 and 8 V is deposited (sub-2 and sub-3, one ganglion); the two mice stimulated at 3 V only are not, so the criterion's count over three mice cannot be made. In this mouse the 3 V response is lower than the 8 V one in all 6 readings (peak dF/F 27.1 to 29.0% against 46.9 to 54.0%) and in each region (block medians 21.1 to 43.6% against 38.0 to 69.9%). At 3 V the rostral region's onset precedes the other three in 12 of 18 variants, all those with the bleaching curve fit outside the response, and not with the whole-trace fit, which takes in part of a response still 9.4 to 16.4% above baseline at 120 s; every earliest block lies in the rostral third in 11 of 18. With the frame flipped top to bottom or turned 180 degrees the rostral region starts first in 0 of 18 variants, so the direction rests on the orientation. Blocked for missing data, as agreed in round 3, since the criterion's partial outcome needs the order in two of three mice and its full outcome in all three, which the one deposited mouse cannot give. If the two missing mice are deposited, rostral is to be read from the electrode side as the criterion says, not from the orientation assumed here.

    Deviations from the paper’s method
    • AQuA (Wang et al. 2019, the paper's ref. 32; Methods, AQuA Analysis) is MATLAB software that cannot be installed in the entry's locked Python environment, and its parameters are not given. Assumed in its place: the onset and peak of 16 x 16 pixel blocks of the pHAb tissue mask (`block_onsets`; onset the first frame from frame 19 that begins 3 frames above the pre-onset mean + 3 SD of the photobleaching-corrected dF/F, peak the largest 3-frame mean), with 32 pixel blocks, 2 and 5 SD and three photobleaching fits as variants. Block onsets measure where and when the signal rises, as AQuA's events do, but AQuA's events and times may differ.
    • The paper's four AQuA areas cannot be located from its text. Regions drawn here from the axis of Figure 7B (rostral up, caudal down, lateral to the left, as the criterion says; the files carry no orientation, and the frame is taken as shown in Fig. 7A) are the rostral, middle and caudal thirds of the tissue's extent along the rows and, for the lateral region, the blocks of the lower two thirds in the quarter of columns furthest to the left; a region's onset and peak are the medians over its blocks.
    • Stimulation onset taken as 10.45 s, frame 19 on the paper's 0.55 s clock, from Fig. 6A ("Sti starts 10.45 s") and Fig. 7A ("Stim starts 10.45 s"); the files do not record it. The responses start 4 to 13 frames after it in sub-2, sub-3 and sub-6.
    • Two of the three 3 V mice are not deposited.
    • Assumed that the bleaching curve is fit to frames outside the response (before onset and from 120 s or 180 s after it); the whole-trace fit, under which the order fails, is shown.
    • Assumed that the deposited frames are oriented as Figure 7A shows them, rostral up and lateral to the left; the files carry no orientation, they are the camera's frames, the paper shows no sign of a flip, and the criterion reads the axis from Figure 7B. A comparison of the panels of Fig. 7A with sub-3, made outside the notebook as the entry reads no figures, agreed, but it is not part of the test. The direction of propagation rests on this assumption: every other orientation is run; flipped top to bottom or turned 180 degrees, the rostral region starts first in no variant, and flipped left to right the lateral region is no longer last at 8 V.

Not tested in a notebook 17

15 data missing from the dataset, 1 metadata insufficient, 1 method cannot be run here

Blocked17

  • Blocked

    By Beer-Lambert estimates at 260, 280 and 652 nm, the nanosensor carries 2.86 AChE, 1.70 BTX and 3.85 pHAb per DNA scaffold, conjugation efficiencies of 71%, 85% and 96%.

    The criterion needs the absorbance spectra of pure DNA scaffold, AChE and BTX to estimate the extinction…

    Data missing from the datasetResults, Fabrication and in vitro characterization, the text around and after Equations 1 and 2; Figure 2F and 2Gfig2g-conjugation-ratios
    From the paper

    the conju-gation ratios of AChE, BTX, and pHAb to DNA scaffold were determined to be 2.86, 1.70, and 3.85 (Fig. 2G). The conjugation efficiency of BTX and pHAb reached 85 and 96%, respectively.

    Result

    The criterion needs the absorbance spectra of pure DNA scaffold, AChE and BTX to estimate the extinction coefficients of Equations 1 and 2. The deposit holds UV-Vis spectra of the nanosensor (eight repeats, a reblank and water, 2019-08-09_sensor.xml) and of the DNA scaffold (2019-08-09_dna_scaffold.xml) only; there are no spectra of AChE or BTX. The SPARC:108 version 1 manifest holds HPLC, UV-Vis and gel files, eight ex vivo calibration recordings of sub-1, in vivo recordings of sub-2 (3 V), sub-3 (8 V), sub-4 (10 V), the confocal stack of sub-5 and the vesamicol pair of sub-6; SPARC:75 holds six confocal LSM images.

  • Blocked

    The nanosensor is 10 to 20 nm across, by structural simulation and atomic force microscopy, against about 130 nm for the earlier version.

    The claim rests on the AFM images of Figure S3B.

    Data missing from the datasetResults, Fabrication and in vitro characterization, the text after Equations 1 and 2; Figure S3figs3-size
    From the paper

    the current ACh nanosensor had an overall size of 10 to 20 nm confirmed by both structural simulations and atomic force microscopy (SI Appendix, Fig. S3)

    Result

    The claim rests on the AFM images of Figure S3B. No AFM file is in either dataset. The SPARC:108 version 1 manifest holds HPLC, UV-Vis and gel files, eight ex vivo calibration recordings of sub-1, in vivo recordings of sub-2 (3 V), sub-3 (8 V), sub-4 (10 V), the confocal stack of sub-5 and the vesamicol pair of sub-6; SPARC:75 holds six confocal LSM images.

  • Blocked

    After rinsing, a substantial amount of nanosensor stays in the SMG, while DNA structures lacking AChE and BTX are barely visible in the tissue.

    Needs widefield images of the SMG after washing for the nanosensor (Fig.

    Data missing from the datasetResults, ACh nanosensors in SMG, paragraph 2; Figure 3B and 3Cfig3bc-retention
    From the paper

    In contrast, DNA structures that did not have the AChE and tar-geting ligands (i.e., BTX) were barely visible inside the tissue (Fig. 3C).

    Result

    Needs widefield images of the SMG after washing for the nanosensor (Fig. 3B) and for bare DNA structures (Fig. 3C). Neither dataset has them. The SPARC:108 version 1 manifest holds HPLC, UV-Vis and gel files, eight ex vivo calibration recordings of sub-1, in vivo recordings of sub-2 (3 V), sub-3 (8 V), sub-4 (10 V), the confocal stack of sub-5 and the vesamicol pair of sub-6; SPARC:75 holds six confocal LSM images.

  • Blocked

    Nanosensors in the harvested SMG keep their structure and AChE activity for 5 h; after 5 h, adding 100 uM ACh raises the pHAb fluorescence of three ROIs by 20 to 45%.

    Needs the confocal images at 0 h and 5 h after harvesting and the ACh test of Figure S4D to F.

    Data missing from the datasetResults, ACh nanosensors in SMG, paragraph 2; Figure S4D to Ffigs4-stability
    From the paper

    The fluorescence intensity of three ROIs increased by 20-45% after the addition of ACh, indicating that the AChE was still functional and remained conjugated on the DNA scaffold.

    Result

    Needs the confocal images at 0 h and 5 h after harvesting and the ACh test of Figure S4D to F. Not in either dataset. The SPARC:108 version 1 manifest holds HPLC, UV-Vis and gel files, eight ex vivo calibration recordings of sub-1, in vivo recordings of sub-2 (3 V), sub-3 (8 V), sub-4 (10 V), the confocal stack of sub-5 and the vesamicol pair of sub-6; SPARC:75 holds six confocal LSM images.

  • Blocked

    The ex vivo nanosensor response to added ACh begins within 0.55 s, the shortest sampling interval used.

    The ex vivo calibration recordings (sub-1) are in the dataset, but the time of ACh addition is not recorded…

    Metadata insufficientResults, Ex vivo calibration of the ACh nanosensors, paragraph 1; Figure S6Afigs6a-response-time
    From the paper

    the initial nanosensor response to ACh addition was within 0.55 s, the minimum sampling time used in our experiment

    Result

    The ex vivo calibration recordings (sub-1) are in the dataset, but the time of ACh addition is not recorded, and the files, resaved in ImageJ, keep only the first frame's timestamp. Six of the eight rise by 19.8 to 58.4% within one frame, at frame 7 to 9; as the criterion says, taking the onset from the response would make the test circular.

  • Blocked

    Normalising the initial rate by the local nanosensor concentration (from AF647 intensity) gives an almost identical Michaelis-Menten curve, EC50 50.35 ± 6.76 uM and Vmax 0.3991 %/(s nM), whose double reciprocal form is Equation 3, 1/V = 126.41/[ACh] + 2.499.

    Needs the AF647 intensity of each calibration ROI and the AF647 calibration on nanosensors of known…

    Data missing from the datasetResults, Ex vivo calibration of the ACh nanosensors, paragraph 2; Equation 3; Figure S6B to Dfigs6b-unit-calibration
    From the paper

    The Vunit sensor–[ACh] relationship was further analyzed by the Michaelis–Menten equation (SI Appendix, Fig. S6B), which showed an almost identical curve to Fig. 4B with an EC50 value of 50.35 ± 6.76 μM.

    Result

    Needs the AF647 intensity of each calibration ROI and the AF647 calibration on nanosensors of known concentration. The sub-1 recordings hold one channel (509 x 255 pixels, half of the camera frame) and no calibration series is deposited. The SPARC:108 version 1 manifest holds HPLC, UV-Vis and gel files, eight ex vivo calibration recordings of sub-1, in vivo recordings of sub-2 (3 V), sub-3 (8 V), sub-4 (10 V), the confocal stack of sub-5 and the vesamicol pair of sub-6; SPARC:75 holds six confocal LSM images.

  • Blocked

    The control nanosensor (pHAb and BTX, no AChE) in tissue rises from 18.50 ± 9.74% at pH 7 to 180.43 ± 17.67% at pH 5, with a pKa of 6.10, close to the 6.2 of free pHAb.

    Needs the ex vivo recordings of control nanosensors under buffers of pH 3.5 to 9 and the free pHAb curve of…

    Data missing from the datasetResults, Ex vivo calibration of the ACh nanosensors, paragraph 3; Figure 4C; Figure S7Afig4c-control-ph
    From the paper

    The signal change from pH 7 to 5 ranged from 18.50 ± 9.74% to 180.43 ± 17.67% with a pKa of 6.10 (Fig. 4C), in accordance with the pKa value of 6.2 represent-ing free pHAb fluorophores

    Result

    Needs the ex vivo recordings of control nanosensors under buffers of pH 3.5 to 9 and the free pHAb curve of Figure S7A. Neither dataset holds pH data or control nanosensor recordings. The SPARC:108 version 1 manifest holds HPLC, UV-Vis and gel files, eight ex vivo calibration recordings of sub-1, in vivo recordings of sub-2 (3 V), sub-3 (8 V), sub-4 (10 V), the confocal stack of sub-5 and the vesamicol pair of sub-6; SPARC:75 holds six confocal LSM images.

  • Blocked

    Control nanosensors (no AChE) show a minimal response to the same 3 V stimulation, so intrinsic pH fluctuation is negligible.

    Needs in vivo recordings of the control nanosensor at 3 V.

    Data missing from the datasetResults, In vivo imaging of ACh release, paragraph 1; Figure 5Bfig5b-control-minimal
    From the paper

    In contrast, we observed a minimal response when control nanosensors were tested, dem-onstrating that the influence of intrinsic pH fluctuation is negli-gible.

    Result

    Needs in vivo recordings of the control nanosensor at 3 V. Every in vivo recording in SPARC:108 is of the ACh nanosensor (subjects sheet and manifest descriptions); no control recording is deposited.

  • Blocked

    At 10 V stimulation the control nanosensor responds with about 50% of the ACh nanosensor's signal, suggesting a pH change at higher stimulation.

    Needs paired 10 V recordings of the ACh and control nanosensors (Figure S8).

    Data missing from the datasetResults, In vivo imaging of ACh release, paragraph 1; Figure S8figs8-control-10v
    From the paper

    upon stimulation with a higher 10 V voltage, control nanosensors responded to ∼50% of the ACh nanosensor signal intensity (SI Appendix, Fig. S8)

    Result

    Needs paired 10 V recordings of the ACh and control nanosensors (Figure S8). Only one 10 V recording, of the ACh nanosensor (sub-4), is deposited.

  • Blocked

    In one ROI of one animal the initial rate grows with stimulation voltage, 0.1886 %/s at 3 V, 3.24 %/s at 5 V and 11.35 %/s at 10 V.

    Needs 3, 5 and 10 V recordings in the same ROI of one animal.

    Data missing from the datasetResults, In vivo imaging of ACh release, paragraph 1; Figure 5Cfig5c-voltage-dose
    From the paper

    with 3 V stimulation increasing 0.1886%/s, 5 V increasing 3.24%/s, and 10 V increasing 11.35%/s, all collected at the same ROI in the ganglia (Fig. 5C)

    Result

    Needs 3, 5 and 10 V recordings in the same ROI of one animal. The deposit has 3 V and 8 V in one ganglion (sub-2, sub-3) and 10 V in another mouse recorded in July 2019 (sub-4); there is no 5 V recording.

  • Blocked

    Through Equation 3, the unit rates at 3, 5 and 10 V (0.0214, 0.0711 and 0.2448 %/(nM s)) give endogenous ACh concentrations of 2.75, 10.49 and 76.51 uM.

    Depends on fig5c-voltage-dose and figs6b-unit-calibration, both blocked for missing data; the AF647…

    Data missing from the datasetResults, In vivo imaging of ACh release, paragraph 2; Figure 5C; Equation 3fig5c-ach-concentration
    From the paper

    we estimated the endogenous ACh concentrations to be 2.75 μM at 3 V, 10.49 μM at 5 V, and 76.51 μM at 10 V

    Result

    Depends on fig5c-voltage-dose and figs6b-unit-calibration, both blocked for missing data; the AF647 calibration is not deposited.

  • Blocked

    Increasing the number of pulses (10, 50, 100 at 3 V) increases the nanosensor response in the same ROI.

    Needs recordings with 10, 50 and 100 pulses at 3 V in one ROI.

    Data missing from the datasetResults, In vivo imaging of ACh release, paragraph 1; Figure 5Dfig5d-pulse-dose
    From the paper

    Similarly, increasing the number of pulses also led to a higher ACh nanosensor response (Fig. 5D).

    Result

    Needs recordings with 10, 50 and 100 pulses at 3 V in one ROI. All deposited 3 V recordings are single stimulations, and none is labelled with another pulse number.

  • Blocked

    Three repeated stimulations (10 V, 10 Hz, 10 ms, 10 pulses) in the same ROI give repeatable initial rates of 0.436, 0.417 and 0.431 %/s (0.428 ± 0.010 %/s).

    Needs one recording with three repeated 10 V, 10-pulse stimulations.

    Data missing from the datasetResults, In vivo imaging of ACh release, paragraph 1; Figure 5Efig5e-reversibility
    From the paper

    showing repeatable rates of 0.436%/s, 0.417%/s, and 0.431%/s in sequence (0.428 ± 0.010%/s, Fig. 5E)

    Result

    Needs one recording with three repeated 10 V, 10-pulse stimulations. The only 10 V recording (sub-4, 509 frames) shows a single response.

  • Blocked

    In vitro, in a dialysis fiber, the nanosensor responds repeatedly to five injections of 100 uM ACh, recovering after each washout.

    Needs the confocal recording of nanosensors in a dialysis fiber with five ACh injections.

    Data missing from the datasetResults, In vivo imaging of ACh release, paragraph 1; Figure S7B; Methods, Characterization of ACh nanosensorsfigs7b-in-vitro-reversibility
    From the paper

    Reversibility of the sensor was demonstrated by three repeated stimulations ... which was confirmed with in vitro experiments (SI Appendix, Fig. S7B).

    Result

    Needs the confocal recording of nanosensors in a dialysis fiber with five ACh injections. Not in either dataset. The SPARC:108 version 1 manifest holds HPLC, UV-Vis and gel files, eight ex vivo calibration recordings of sub-1, in vivo recordings of sub-2 (3 V), sub-3 (8 V), sub-4 (10 V), the confocal stack of sub-5 and the vesamicol pair of sub-6; SPARC:75 holds six confocal LSM images.

  • Blocked

    dF/F traces from AQuA events and from conventional ROI analysis of the same regions show similar dynamics.

    AQuA (Wang et al. 2019, the paper's ref. 32) is MATLAB software; it cannot be installed in the entry's locked…

    Method cannot be run hereResults, ACh nanosensor response reflects physiological ACh propagation, paragraph 1; Figure S9figs9-aqua-vs-roi
    From the paper

    we compared the fluorescence dynamics derived from AQuA software to the ROI-based analysis at the same regions that were automatically defined by AQuA software and found that they reported similar dynamics (SI Appendix, Fig. S9)

    Result

    AQuA (Wang et al. 2019, the paper's ref. 32) is MATLAB software; it cannot be installed in the entry's locked Python environment, and the paper names its parameters (intensity threshold scaling factor, Gaussian smoothing, temporal cut threshold, super-event grouping) without values. The 8 V recording it needs (sub-3) is deposited. The block-onset substitute used for Figure 7 cannot stand in here, as the claim compares AQuA's own output with ROI traces.

  • Blocked

    Control nanosensors change by less than 4% under 8 V stimulation (three mice), so physiological pH changes are small.

    Needs 8 V recordings of the control nanosensor in three mice (Figure S10).

    Data missing from the datasetResults, ACh nanosensor response reflects physiological ACh propagation, paragraph 1; Figure S10figs10-control-8v
    From the paper

    It is worth noting that control nanosensors change less than 4% under 8 V stimulation

    Result

    Needs 8 V recordings of the control nanosensor in three mice (Figure S10). None is deposited; the only 8 V recording (sub-3) is of the ACh nanosensor.

  • Blocked

    pHAb fluorophores can be excited by two-photon microscopy, and a whole SMG injected with control nanosensors can be imaged under two-photon excitation at 837 nm.

    Needs the two-photon images of Figure S13 (pHAb oligos at several wavelengths and an SMG at 837 nm).

    Data missing from the datasetDiscussion, paragraph 1; Figure S13figs13-two-photon
    From the paper

    pHAb fluorophores are also compatible with two-photon imaging (SI Appendix, Fig. S13)

    Result

    Needs the two-photon images of Figure S13 (pHAb oligos at several wavelengths and an SMG at 837 nm). Not in either dataset. The SPARC:108 version 1 manifest holds HPLC, UV-Vis and gel files, eight ex vivo calibration recordings of sub-1, in vivo recordings of sub-2 (3 V), sub-3 (8 V), sub-4 (10 V), the confocal stack of sub-5 and the vesamicol pair of sub-6; SPARC:75 holds six confocal LSM images.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Paper inconsistentFigure S2C calls itself the same gel as Figure 2E but labels lane 1 as unpurified ACh nanosensor, where Figure 2E has the DNA scaffold. In the deposited gel, lane 1 has a single pHAb band and no AF647 band, as a scaffold without BTX would, so Figure S2C's label looks wrong.#
  • Methods not availableQuestions for the authors. (1) Over which frames is the initial rate (Vsensor) taken, from which onset, and against which baseline; and when was ACh added in each calibration recording and the stimulation started in each in vivo recording? Assumed here, onset at the largest one-frame rise (ex vivo) and at 10.45 s (in vivo, from Fig. 6A and 7A), with every rate window the claims file names. (2) Which ROI was used in Figures 5B and 6B, and which deposited recordings are the three mice of Figure 5B? Here the tissue, the whole frame and cell-sized blocks were run, giving 17.1 to 40.1% against 3.7%. (3) Which frame interval applies, the 0.55 s of the paper or the 0.50 s the files record? (4) Which flow rate was used for the HPLC (none is stated, so the retention volumes could not be tested), and how were the peaks of Figure 2D integrated, given that the main peak and the second peak overlap and that the share is 65.8 to 68.2% with a flat baseline and 77.5 to 83.1% with a line under each peak? (5) Which frames was the photobleaching curve fit to? (6) Which AQuA version and parameters were used for Figure 7 and Figures S9 to S12, and where are the four numbered areas of Figure 7A? Block onsets were used in its place here, on the frame as deposited; does rostral lie at the top of the deposited frames, as Fig. 7A shows them? (7) How is the background of the puncta threshold of Figure 3D defined?#

Questions about the claims 1

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • openasked 2026-11-18about fig7-peak-timing

    The criterion reads "10 to 15 s" in two ways, from stimulation onset (i) or from each event's own onset (ii), and counts a pass under either. It flags the paper's contradiction only for the most caudal region. But the paper's own Figure 7B and text times do not fit reading (ii) for the rostral-most region either. It rises at 13.20 s and peaks at 22.0 s, 8.80 s after its own onset and outside 9 to 16.5 s, while from stimulation onset (10.45 s) it peaks after 11.55 s, inside the window. Should reading (ii) stand, or does the paper mean reading (i) only, with the most caudal region as the one exception the criterion already names?

    Passage. The rostral-most region started to increase fluorescence at 13.20 and 2.75 s after the start of 10 s stimulation and peaked at t = 22.0 s, 1.65 s after the last stimulation. ... The decay of fluorescence intensity of the most caudal region begins at t = 44.55 and 24.2 s after the last stimulation (Fig. 7B). ... All evoked nanosensor responses in Fig. 7A climbed to the peak around ~10 to 15 s, an observation consistent with Fig. 5 B-E. (Results, ACh nanosensor response reflects physiological ACh propagation, paragraph 1)

    Why it matters. The attempt passes only under reading (ii). The four regions of sub-3, with block onsets in place of AQuA, peak 11.8 to 18.1 s after their own onsets (all four within 9 to 16.5 s in 30 of 36 variants), and 18.0 to 26.4 s after stimulation onset (0 of 36 variants, none even with the most caudal region left out). If reading (ii) is dropped, the outcome would be not reproduced. Raised by the round-2 verifier, who would give partially reproduced at most.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Imaging acetylcholine release with a DNA nanosensor (Xia et al. 2021)

Tests the findings of Xia, Yang, Mu, Micovic, Poskanzer, Monaghan and Clark (2021) on SPARC:108, which holds the nanosensor's HPLC, UV-Vis and gel data, ex vivo calibration recordings of one mouse, in vivo recordings at 3, 8 and 10 V, a confocal stack of a stained ganglion and one vesamicol experiment, and on SPARC:75, which holds confocal images of a ganglion stained with BTX or the nanosensor. The control nanosensor, pH, voltage and pulse series, AFM, stability and two-photon data are not deposited, and the AQuA analysis was not run. Also uses SPARC:75. All files

Environment: Python 3.13, 36 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Imaging acetylcholine release with a DNA nanosensor (Xia et al. 2021)

Tests the findings of Xia, Yang, Mu, Micovic, Poskanzer, Monaghan and Clark (2021) on SPARC:108, which holds the nanosensor's HPLC, UV-Vis and gel data, ex vivo calibration recordings of one mouse, in vivo recordings at 3, 8 and 10 V, a confocal stack of a stained ganglion and one vesamicol experiment, and on SPARC:75, which holds confocal images of a ganglion stained with BTX or the nanosensor. The control nanosensor, pH, voltage and pulse series, AFM, stability and two-photon data are not deposited, and the AQuA analysis was not run. Also uses SPARC:108. All files

Environment: Python 3.13, 36 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-18
    Agreed with 26 of 29 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The first executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper's full text. The verifier read the archive's file list and metadata and tested initial_rate, fit_mm, two_line_crossing, bleach_correct and dff on synthetic inputs. It found no place where the claims file misreads the paper.
    • fig7-rostral-caudal: the verifier’s outcome was “Blocked”. The 8 V recording (sub-3) is deposited, so part of the claim could be tested: block-wise onset and peak times on sub-3 could test the onset order, though not with AQuA. The reason not_runnable is not allowed; it should be other.
    • fig7-peak-timing: the verifier’s outcome was “Blocked”. Block-wise peak times on sub-3 could test the 10 to 15 s time to peak (9 to 16.5 s), though not with AQuA. The reason should be other.
    • figs12-3v-propagation: the verifier’s outcome was “Blocked”. Part could be tested. The amplitude comparison in the mouse stimulated at both voltages is already there: sub-2 at 3 V peaks at 27.1%, sub-3 at 8 V at 48.1%, so 3 V is lower. Propagation could only be checked in sub-2; the two 3 V-only mice are not identified in the deposit.
  • Round 2
    2026-11-18
    Agreed with 27 of 29 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2: the full executed notebook of the author-revise-1 run with its conclusions and summary, the helper module xia2021.py, the attempt record, the README and the claims file, with the paper. Report in transcripts/xia-2021/verifier-2-report.md.
    • fig7-peak-timing: the verifier’s outcome was “Partially reproduced”. Would call it partially reproduced at most. It passes only under reading (ii), timed from each region's onset (30 of 36 variants). Those onsets come 2.75 to 3.3 s after the paper's for the rostral region, and the parent claim matches 0 of 6 times. Timed from the stimulus, reading (i), it fits in 0 of 36 variants and 0 of 157 blocks. Reading (ii) applied to the paper's own Fig. 7B times gives 8.8 s for the rostral region (22.0 - 13.20), outside 9 to 16.5 s. The claims file flags the paper's contradiction only for the caudal region.
    • figs12-3v-propagation: the verifier’s outcome was “Blocked”. The criterion grants partial "when two of three show the order". Only one mouse is deposited, so that threshold cannot be reached. The amplitude part holds (6 of 6 readings), and the order holds in 12 of 18 variants on the median onset and 11 of 18 on the earliest block. These results should be reported without the label "partial", or the claim should be blocked for the two missing mice. The direction of propagation also depends wholly on an orientation checked outside the notebook.
  • Round 3
    2026-11-18
    Agreed with 1 of 1 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 3: the one proposed outcome change (figs12-3v-propagation), checked against the executed notebook of the author-revise-2 run, the attempt record and the claims file, with the paper. Report in transcripts/xia-2021/verifier-3-report.md.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • Stimulation onset taken as 10.45 s, frame 19 on the paper's 0.55 s clock, from Fig. 6A ("Sti starts 10.45 s") and Fig. 7A ("Stim starts 10.45 s"); the files do not record it. The responses start 4 to 13 frames after it in sub-2, sub-3 and sub-6.fig5b-in-vivo-response fig6-vesamicol fig7-rostral-caudal fig7-peak-timing figs12-3v-propagation
  • AQuA (Wang et al. 2019, the paper's ref. 32; Methods, AQuA Analysis) is MATLAB software that cannot be installed in the entry's locked Python environment, and its parameters are not given. Assumed in its place: the onset and peak of 16 x 16 pixel blocks of the pHAb tissue mask (`block_onsets`; onset the first frame from frame 19 that begins 3 frames above the pre-onset mean + 3 SD of the photobleaching-corrected dF/F, peak the largest 3-frame mean), with 32 pixel blocks, 2 and 5 SD and three photobleaching fits as variants. Block onsets measure where and when the signal rises, as AQuA's events do, but AQuA's events and times may differ.fig7-rostral-caudal fig7-peak-timing figs12-3v-propagation
  • The paper's four AQuA areas cannot be located from its text. Regions drawn here from the axis of Figure 7B (rostral up, caudal down, lateral to the left, as the criterion says; the files carry no orientation, and the frame is taken as shown in Fig. 7A) are the rostral, middle and caudal thirds of the tissue's extent along the rows and, for the lateral region, the blocks of the lower two thirds in the quarter of columns furthest to the left; a region's onset and peak are the medians over its blocks.fig7-rostral-caudal fig7-peak-timing figs12-3v-propagation
  • Assumed that the deposited frames are oriented as Figure 7A shows them, rostral up and lateral to the left; the files carry no orientation, they are the camera's frames, the paper shows no sign of a flip, and the criterion reads the axis from Figure 7B. A comparison of the panels of Fig. 7A with sub-3, made outside the notebook as the entry reads no figures, agreed, but it is not part of the test. The direction of propagation rests on this assumption: every other orientation is run; flipped top to bottom or turned 180 degrees, the rostral region starts first in no variant, and flipped left to right the lateral region is no longer last at 8 V.fig7-rostral-caudal fig7-peak-timing figs12-3v-propagation
  • Frame interval run at 0.55 s (Results, Ex vivo calibration, "0.55 s, the minimum sampling time") and at 0.50 s, the interval the per-frame timestamps of sub-2 and sub-3 record.fig4b-michaelis-menten fig5b-in-vivo-response
  • Photobleaching correction by a monoexponential curve, each value divided by the curve (Methods, Animal Preparation and Imaging); the frames it is fit to are open, and both readings of the claims file (frames outside the response, whole trace) were run.fig4b-michaelis-menten fig6-vesamicol
  • The paper gives no flow rate (Methods name the Superdex 200 increase 10/300 GL column and the Agilent Infinity 1260 HPLC only), and the files give time, so the main and second peak volumes are not tested. The first version assumed 0.5 mL/min, chosen because it put the peaks at the paper's volumes, which made that test circular.fig2d-hplc-yield
  • "Detectable" peaks taken as those with a prominence of at least 1% of the largest (0.5% as a variant), a choice made here.fig2d-hplc-yield
  • Assumed that the second peak ends where its own descent ends (slope below 1% of the steepest, 20.53 min), the usual limit of a peak; ends where it falls below 2% of its height and where the signal returns to the pre-injection level + 3 SD (29.76 min, the first version) are shown. The share under reading (b) depends on it.fig2d-hplc-yield
  • Lanes found as runs of columns with signal and bands as lane-profile peaks with a prominence of at least 5% of the profile range, choices made here as the paper gives no quantification. The ethidium image is framed differently from the fluorescence pair, so band positions are compared within each.fig2e-page-bands
  • Puncta defined as components above the median + 3 SD of the lower half of the pixels reflected about the median, 0.1 to 25 um^2, and the GFP mask by Otsu's threshold or the same background rule; the first rule (mean + 3 SD of the below-median pixels) is shown as a variant. The paper gives no quantification, and these support, not replace, the judgement by eye the criterion asks for.figs5-btx-staining
  • Assumed that the by-eye reading (a) is judged together with chance references, a 5 um shift of the pHAb mask and the share of the field covered by the soma mask, as the paper gives no colocalisation measure; the shift, the punctum size limits (0.1 to 25 um^2) and the soma masks (Otsu, background rule, 1 um margin) are choices made here.fig3d-sensor-on-soma
  • The background of the claims file's mean + 3 SD threshold is not defined in the paper. Since round 1 it is the lower half of the pixels reflected about the median (threshold median + 3 SD), the usual half-Gaussian estimate; the first rule, mean + 3 SD of the below-median pixels, sets the threshold about 1 SD above the centre of a Gaussian and marked a third or more of the field, and is shown as a variant.fig3d-sensor-on-soma
  • SPARC:75's nanosensor images are single planes and are used with the sub-5 stack.fig3d-sensor-on-soma
  • One of three mice and 8 of the paper's concentrations (to 714 uM, not 7.14 mM) are deposited; means over mice and all points are the same here.fig4b-michaelis-menten
  • Assumed that ACh was added just before the largest one-frame rise of each recording, as the addition time is not recorded; at 0.00714 and 0.0714 uM there is no clear step, so this onset is noise there.fig4b-michaelis-menten
  • The ROI is not given; the stained tissue (Otsu mask of the first frame) and the whole frame were run.fig4b-michaelis-menten
  • Rate reading (a) fits from the last frame before the response to the peak, so that a rise within one frame is included; reading (b) over the first 2 to 5 frames.fig4b-michaelis-menten
  • Reading (c), the split of Figure 4B(ii), was not run, as it needs the figure's lines and the entry reads no figures.fig4b-lod
  • Rests on the rates and onset assumption of fig4b-michaelis-menten, one mouse of three.fig4b-lod
  • Assumed that the deposited 3 V recordings stand for the three mice of Figure 5B; the deposit does not identify them, and sub-2 is the 3 V recording of the AQuA mouse.fig5b-in-vivo-response
  • The ROI is a hand-drawn ganglion cell in the paper (Fig. 5B legend) with no coordinates; tissue, whole frame, tissue without saturating pixels, tissue less the camera's dark level and 40 x 40 pixel blocks were run.fig5b-in-vivo-response
  • Photobleaching correction by a monoexponential curve, each value divided by the curve (Methods, Animal Preparation and Imaging); the frames it is fit to are open, and the frames before onset with those from 120 s or from 180 s after it, and the whole trace, were run.fig5b-in-vivo-response
  • Initial rate over k frames counted from the last frame before the trace leaves baseline (|z| > 5), as the responses start 6 to 10 frames after the assumed stimulation onset; the rates from frame 19 are shown and not counted.fig5b-in-vivo-response
  • Channel taken as pHAb is the right half in sub-2 (the half that rises), the single channel in sub-6.fig5b-in-vivo-response
  • One experiment of four; the reduction is that of this experiment, not a mean over four.fig6-vesamicol
  • Assumed that sub-6 is the example of Figure 6A and 6B (it is the only one deposited).fig6-vesamicol
  • The ROI of Figure 6A is not given; tissue, whole frame, tissue without saturating pixels and 40 x 40 blocks were run. Peak taken from onset to 120 s after it, the end of the response by the paper's "within 2 min".fig6-vesamicol
  • A 3-frame median filter is shown as a variant, for two single low frames in each recording.fig6-vesamicol
  • The within-experiment paired t test is also run on the means of non-overlapping 10 s bins, as consecutive frames are not independent.fig6-vesamicol
  • Times are frame x 0.55 s, the paper's clock; the 0.50 s of the files is shown.fig7-rostral-caudal
  • Two of the three 3 V mice are not deposited.figs12-3v-propagation
  • Assumed that the bleaching curve is fit to frames outside the response (before onset and from 120 s or 180 s after it); the whole-trace fit, under which the order fails, is shown.figs12-3v-propagation
  • Assumed that the left half of the W-VIEW GEMINI frame is AF647 and the right half pHAb; the files carry no channel labels, and the right half is the one that rises. The test then shows that one channel stays flat while the other rises.figs16-af647-stable
  • Whole SMG read as each channel's tissue mask, the whole half-frame, and the pHAb tissue mask applied to the AF647 half; onset as in fig5b (frame 19).figs16-af647-stable

Provenance

Attempt record
xia-2021-01
Paper
10.1073/pnas.2023807118
Date
2026-11-18
Made by
An agent, run by CatalystNeuro
Dataset
SPARC:108 (on SPARC)
Version
1 (doi:10.26275/w027-cisv)
Dataset
SPARC:75 (on SPARC)
Version
1 (doi:10.26275/prjd-jhoc)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-16

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 4 findings reproduced, Xia et al. 2021

It counts the paper’s findings reproduced in full in a current attempt, verified or not. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/xia-2021/"><img src="https://encorescience.org/badge/papers/xia-2021-reproduced.svg" alt="Encore: 4 findings reproduced, Xia et al. 2021"></a>

Or as Markdown:

[![Encore: 4 findings reproduced, Xia et al. 2021](https://encorescience.org/badge/papers/xia-2021-reproduced.svg)](https://encorescience.org/papers/xia-2021/)

The same numbers are in this page’s JSON, under badge (how it is counted).