Datasets / SPARC:108

Imaging in vivo acetylcholine release in the peripheral nervous system with a fluorescent nanosensor in mice

2.2 GB 73 files

Tested on dataset version 1

View on SPARC JSON

Papers tested on this dataset 1

Each opens the paper’s page, with every claim, its outcome and the notebook that tested it.

Imaging in vivo acetylcholine release in the peripheral nervous system with a fluorescent nanosensor

4 reproduced · 4 partially reproduced · 3 not reproduced · 18 blocked
Attempt xia-2021-01 on version 1
Not yet verified2026-11-18

Open findings about the data 7

What the attempts that used this dataset found about the data themselves, for its owner and the archive, under the version of the dataset each was found on.

Dataset version 1 · tested 2026-11-18 · 7 open findings

  • Data missingSPARC:108 holds only part of the data the paper reports. Deposited are one of three ex vivo calibration mice (8 concentrations, none above 714 uM), one of four vesamicol experiments, the 3 V and 8 V recordings of the AQuA mouse, one 10 V recording, the nanosensor HPLC, UV-Vis and gel files and one confocal stack. Not deposited are every control nanosensor recording (Fig. 4C, 5B, S8, S10), the pH calibrations (Fig. 4C, S7A), the 5 V, pulse-number and repeated stimulations (Fig. 5C to E), the AF647 concentration calibration (Fig. S6B), the AFM images (Fig. S3), the spectra of pure AChE and BTX (Fig. 2G), the retention, stability, fiber and two-photon images (Fig. 3B-C, S4, S7B, S13) and two of the three 3 V AQuA mice (Fig. S12). Sixteen of the 29 claims are blocked for missing data and one for missing metadata.#
    Found by the attempt on Xia et al. 2021 (xia-2021-01, 2026-11-18)
  • Description missingThe imaging recordings lack what is needed to analyse them. No file says which half of the W-VIEW GEMINI frame is pHAb and which AF647; no file gives a spatial scale (the camera calibration is in pixels); the stimulation onset and the time of ACh addition are not recorded; and the files resaved in ImageJ (sub-1, sub-4, sub-6) keep only the first frame's timestamp, so their frame interval is unknown. The paper gives the onset only as 10.45 s in two figures, and sub-4 does not follow it (its response starts near frame 55 or later).#
    Found by the attempt on Xia et al. 2021 (xia-2021-01, 2026-11-18)
  • Metadata errorThe primary manifest.xlsx of SPARC:108 describes its files under names that are not in the dataset (40 of 50 differ, for example sub-1/0.000714_uM.tif for sub-1/sub-1_0.000714 uM); seven of the eight calibration files lack the .tif extension; and the sheet describes the sub-1 calibration recordings, made with added ACh, as "ACh release by electrical stimulation".#
    Found by the attempt on Xia et al. 2021 (xia-2021-01, 2026-11-18)
  • Metadata errorsubjects.xlsx lists sub-2 (3 V) and sub-3 (8 V) as two mice, but their recordings were made 14 minutes apart on one day and show the same field (mean images r = 0.93 with no shift, against 0.06 to 0.47 between other recordings), as the paper's one mouse stimulated at 3 and 8 V (Methods, AQuA Analysis).#
    Found by the attempt on Xia et al. 2021 (xia-2021-01, 2026-11-18)
  • OtherThe per-frame timestamps of the in vivo recordings that keep them (sub-2, sub-3) give an interval of 0.50 s, while the paper states 0.55 s as its sampling interval and its Figure 7 times are multiples of 0.55 s. Rates in %/s differ by 10% between the two.#
    Found by the attempt on Xia et al. 2021 (xia-2021-01, 2026-11-18)
  • OtherMany pixels saturate at 65535 in the sub-6 vesamicol recordings (19.6% of tissue pixels at some frame with the drug, 69.0% after washout) and in the pHAb half of sub-2 and sub-3 (11.5% and 16.4%), which clips the responses the paper's Figure 6 ratio is computed from.#
    Found by the attempt on Xia et al. 2021 (xia-2021-01, 2026-11-18)
  • Description missingNeither dataset names the PNAS paper. SPARC:108's dataset_description gives the bioRxiv preprint (10.1101/2020.07.06.189696) as its originating article, and SPARC:75 gives none, so its link to the paper (Figure S5 and the nanosensor staining) rests on its content.#
    Found by the attempt on Xia et al. 2021 (xia-2021-01, 2026-11-18); also about SPARC:75

Badges for this dataset

Encore: 4 reproduced, 4 partially reproduced, 3 not reproduced, 18 blocked, of 29 claims tested on SPARC:108

It counts every claim tested on this dataset in a current attempt, verified or not, over every paper tested on it. To show it on the dataset’s own page, linked to this page:

<a href="https://encorescience.org/datasets/sparc/108/"><img src="https://encorescience.org/badge/sparc/108-outcomes.svg" alt="Encore: 4 reproduced, 4 partially reproduced, 3 not reproduced, 18 blocked, of 29 claims tested on SPARC:108"></a>

Or as Markdown:

[![Encore: 4 reproduced, 4 partially reproduced, 3 not reproduced, 18 blocked, of 29 claims tested on SPARC:108](https://encorescience.org/badge/sparc/108-outcomes.svg)](https://encorescience.org/datasets/sparc/108/)

The same numbers are in this page’s JSON, under badge (how it is counted).