Papers / Schapiro et al. 2024

Ih block reveals separation of timescales in pyloric rhythm response to temperature changes in Cancer borealis

Outcomes of 25 claims

  • 20 reproduced
  • 1 partially reproduced
  • 4 blocked

Summary: Most of the paper's main findings hold up in this data. Blocking Ih with Cs+ lowered pyloric frequency and its Q10, made frequency fall more often during warming and rise more often at stable temperature, and advanced PD and LP phases while PY phase held constant. The LP advance in Cs+ holds only when 1.6% of cycles, which the deposited code leaves spanning several bursts, are set aside. Picrotoxin restoring the frequency change held only partly: two preparations fell short of the top temperature and the result depends on the Tukey variant. The minor voltage-clamp Ih reduction and two control Q10 comparisons could not be tested, as the Cs+ clamp trials and most control spike files are not deposited.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Schapiro et al. (2024) from Dryad dataset 1rn8pk129 25 Open in Colab

Reproduced20

  • Reproduced

    At 11 degrees C pyloric frequency was lower in Cs+ than in saline (0.9 against 1.2 Hz, paired t-test p < 0.001).

    Mean frequency in the first 11 C hold is 1.17 +- 0.15 Hz in saline and 0.86 +- 0.22 Hz in Cs+ over the 20…

    Results, The steady-state frequency increase in response to elevated temperature was decreased by Cs+, paragraph 2fig1-cs-lower-frequency-11c
    From the paper

    In Cs + at 11°C, the pyloric frequency was significantly decreased compared to control conditions (saline ... 1.2±0.2 Hz; Cs + 0.9±0.2 Hz, paired Student’s t-test; p < 0.001)

    Reported statistics
    • paired Student's t-test, p < 0.001 (n = 21 experiments)
    Result

    Mean frequency in the first 11 C hold is 1.17 +- 0.15 Hz in saline and 0.86 +- 0.22 Hz in Cs+ over the 20 experiments with both values, lower in Cs+ in all 20, paired t = 7.18, p = 8e-07. 969_070 has no Cs+ cycle within 0.3 C of 11 C. The deposited code's strict bound for Cs+ (< 0.3 C) and the <= bound give the same values, as do the gap cycles kept.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • 20 of the 21 experiments enter; 969_070 has no 11 C Cs+ value.
    • The Cs+ frequency is the mean over cycles with |T - target| < 0.3 C and the saline frequency over <= 0.3 C, as in the deposited CalculateFrequencyPhaseEtc.m; the <= bound for both is shown as a variant.
  • Reproduced

    The difference between a preparation's frequency in saline and in Cs+ increased significantly as temperature increased.

    Saline minus Cs+ frequency rises from 0.31 Hz at 11 C to 0.83 Hz at 21 C (0.37, 0.50, 0.61, 0.73 between).

    Results, The steady-state frequency increase, paragraph 3; Figure 1D legendfig1d-difference-grows-with-temperature
    From the paper

    As temperature increased, the difference between a preparation’s frequency in saline and Cs + significantly increased (one-way repeated measures ANOVA [F(5,85) = 43.259, p<0.001, N=21])

    Reported statistics
    • one-way repeated measures ANOVA, F(5,85) = 43.259, p < 0.001 (n = 21 experiments)
    Result

    Saline minus Cs+ frequency rises from 0.31 Hz at 11 C to 0.83 Hz at 21 C (0.37, 0.50, 0.61, 0.73 between). One-way repeated-measures ANOVA over the 19 experiments with all six values (readings a and b give the same set; 969_070 and 969_128 are incomplete), F(5,90) = 44.1, p = 9e-23; every variant gives F >= 44.0. The paper's F(5,85) is from 18 experiments; the deposited TotalDiffs gives exactly F(5,85) = 43.259, and lacks the 11 C Cs+ value of 969_068 that the spike file gives here.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • 19 experiments enter where the paper's degrees of freedom imply 18.
  • Reproduced

    The Q10 of pyloric frequency was lower in Cs+ (1.3) than in saline (1.7), paired t-test p < 0.001, N=21.

    Reading (a), the fitted Q10 equation, gives 1.68 +- 0.32 in saline and 1.35 +- 0.45 in Cs+ over 21…

    Results, The steady-state frequency increase, paragraph 3; Figure 1Efig1e-q10-lower-in-cs
    From the paper

    The mean Q 10 of the pyloric frequency was significantly lower in Cs + (1.3±0.5) than in control (1.7±0.3) ( Figure 1E )

    Reported statistics
    • paired Student's t-test, p < 0.001 (n = 21 experiments)
    Result

    Reading (a), the fitted Q10 equation, gives 1.68 +- 0.32 in saline and 1.35 +- 0.45 in Cs+ over 21 experiments, paired t p = 4.1e-05, lower in Cs+ in 18. Reading (b), the log-linear fit of the deposited code, gives 1.71 +- 0.33 and 1.35 +- 0.50 (p = 0.00011); reading (c), the two-point ratio, 1.71 and 1.34 over 19 experiments with both end values (p = 0.00014). The variants of the 11 C hold agree.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • Q10 is fitted to the six holding-temperature means against their measured mean temperatures, as the deposited CalculateFrequencyPhaseEtc.m does (fitlm(ActualTempSal, log10(SalineAvg_BF))).
  • Reproduced

    In experiments with two consecutive saline step protocols, the frequency change from 11 to 21 degrees C did not differ between the first (0.9 Hz) and second (0.8 Hz) protocol.

    Over the 6 control experiments, the 21 C minus 11 C frequency is 0.89 +- 0.30 Hz for the first protocol and…

    Results, The steady-state frequency increase, paragraph 4; Figure 1Fquestion to the readerfig1f-two-saline-frequency-change-same
    From the paper

    The mean difference in frequency between 21°C and 11°C for the first (0.9±0.3 Hz) and second temperature changes (0.8±0.3 Hz) were not significantly different ( Figure 1F )

    Reported statistics
    • paired Student's t-test, p = 0.14 (n = 6 experiments)
    Result

    Over the 6 control experiments, the 21 C minus 11 C frequency is 0.89 +- 0.30 Hz for the first protocol and 0.78 +- 0.30 Hz for the second (mean difference 0.11 Hz); paired t(5) = 1.77, p = 0.137, so the paper's test does not find a difference. For 981_025, the one control experiment with a spike file, the changes recomputed from spikes are 1.22 and 1.00 Hz against the table's 1.19 and 0.99. The claims file calls the controls two step protocols, where the paper says two consecutive temperature changes; this is asked as a question for a reader (questions/schapiro-2024.yaml).

    Deviations from the paper’s method
    • The values are the deposited per-experiment means of ControlTable (SummaryStatistics.mat), not computed from spike times: five of the six control experiments (965_129, 965_134, 965_139, 965_146, 982_005) have no spike file. How the table's 11 and 21 C means were formed is not documented.
    • The table gives the second protocol as a ramp, not steps, in three of the six experiments (965_146, 981_025, 982_005); the claims file describes two step protocols, the paper two consecutive temperature changes.
  • Reproduced

    In an example preparation in Cs+, the frequency decrease right after the temperature step from 13 toward 15 degrees C came from an elongation of the PD depolarizing phase, not of the bursting, repolarization or inhibitory phases; a Cs+ + PTX example showed the same.

    Under reading (a), on the two Cs+ experiments with an intracellular PD trace and spike times (969_113, the…

    Results, Cs+ revealed dynamic transitory frequency response, paragraph 1; Figure 2C legend; Results, In Cs+, follower neurons determined frequency-temperature sensitivity, paragraph 3, and Figure 4G for Cs+ + PTX; Discussion, The jags in frequency, paragraph 2fig2c-decrease-by-depolarizing-phase
    From the paper

    Alignment of each PD cycle during this window to the first PD spike reveals that the decrease in frequency was due to elongation of the depolarizing phase and not the bursting, repolarization, or inhibitory phases

    Result

    Under reading (a), on the two Cs+ experiments with an intracellular PD trace and spike times (969_113, the paper's Figure 2 example, step onset at 67.9 min as in the deposited plotting call, and 969_115), the depolarizing phase carries 1.29 and 1.63 of the period increase in the first 30 s of warming from 13 C, the burst 0.05 and 0.02, and the repolarization shrinks (-0.34 and -0.66 of it); the period rose by 78 and 26 ms. With the gap cycles kept the shares change by at most 0.015. Under reading (b), from spikes, the depolarizing phase carries more than half in 4 of the 5 experiments marked intracellular (0.35 in 969_115, where the repolarization to the first LP spike carries 0.76), and in 17 of the 20 Cs+ experiments with a period increase (median 0.87; 16 of 20 with the gap cycles kept). The statement's Cs+ + PTX example, outside the criterion, also holds. It is Raw_Expt_981_037.mat, the trace the deposited script plots as the example of jag in PTX (its Figure 5F,G, the paper's Figure 4F,G), with no spike file. On PD spikes detected on the trace, in the first 30 s of the warming at 16.10 min (from 11.3 C, not 13 C) the period rises from 1628 to 2146 ms and the depolarizing phase carries 0.96 of the increase, the burst -0.01 and the repolarization 0.06. No other raw file can add a Cs+ warming with an intracellular PD trace. 969_087 and 969_147 are extracellular only and 969_137 holds PY; 981_007 has an intracellular PD trace, which the deposited script plots as the saline and Cs+ example of the paper's Figure 5E, but its temperature stays between 9.6 and 11.7 C over 187 min, so it has no warming step. In 969_152 under Cs+ + PTX no LP spike falls within 30 s of the step onset, so reading (b) cannot be formed there.

    Deviations from the paper’s method
    • Step onset is the first cycle of the warming from 13 C (traced back from the first cycle above 13.3 C while the smoothed temperature rose by more than 0.01 C per cycle, the crossing taken being the first after which the temperature reaches 14.7 C without falling back below 13 C), a standard choice built on the paper's increasing-temperature rule; the paper marks the onset by eye (Figure 2, maroon line).
    • The voltage minimum is taken on a 5 ms moving average of the PD trace, a standard choice.
    • Reading (a) is run on 2 experiments, the only Cs+ ones with a deposited intracellular PD trace and spike times.
    • The Cs+ + PTX example (981_037) is analysed outside the criterion, on PD spikes detected on its intracellular trace (peaks above -40 mV standing 10 mV above their surroundings, a standard choice; spikes peak near -29 mV from a trough near -70 mV), on its warming from 11 C, the step the deposited script plots; its condition is known only from the script's comment.
  • Reproduced

    Among temperature-increasing cycles, the percent with a frequency decrease was higher in Cs+ (31.4%) than in saline (7.5%), and higher in Cs+ in 20 of 21 experiments.

    Centred smoothing over the Timings window (the deposited ProbabilityUpDown.m), percent of warming cycles with…

    Results, Cs+ revealed dynamic transitory frequency response, paragraph 2; Figure 3Dfig3d-freq-decrease-while-warming
    From the paper

    In Cs + , the mean percent of temperature-increasing pyloric cycles in which the frequency decreased (31.4±15%) was significantly higher than in control (7.5±5%) ( Figure 3D , paired Student’s t-test, N=21, p<0.001)

    Reported statistics
    • paired Student's t-test, p < 0.001 (n = 21 experiments)
    Result

    Centred smoothing over the Timings window (the deposited ProbabilityUpDown.m), percent of warming cycles with a frequency decrease, 31.0 +- 15.7 in Cs+ and 6.3 +- 4.8 in saline, higher in Cs+ in 20 of 21, paired t p = 4e-07. The other six readings (centred or trailing; the step protocol, O3 a; the window extended over the cooling to 11 C, O3 b; smoothing within the window) give 28.0 to 31.6 against 5.1 to 7.2, 20 of 21 and p < 2e-05 each. Per experiment the values are close to the deposited Sawtooth.mat (31.4 and 7.5 on average).

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • Stable cycles are those with a smoothed temperature change within +-0.01 C per cycle in the window reading, as the deposited code and the Figure 3A legend ('change less than 0.01 C/pyloric cycle') have it; the step and cooling readings count every cycle with a change <= 0.01 C as stable, as the Methods and the claims file header say.
    • The Timings windows end at the 21 C hold, so O3 (b) extends each window to the first cycle back within 0.3 C of 11 C, the cooling that precedes the solution change (Methods, Temperature protocol).
    • Smoothing runs over the whole recording, across condition boundaries, as the deposited code does; smoothing within the window is shown as a variant.
  • Reproduced

    Among temperature-stable cycles, the percent with a frequency increase was higher in Cs+ (27.6%) than in saline (14.1%), and higher in Cs+ in 20 of 21 experiments.

    Centred window reading, percent of stable cycles with a frequency increase, 26.9 +- 6.2 in Cs+ and 13.2 +- 5.4…

    Results, Cs+ revealed dynamic transitory frequency response, paragraph 2; Figure 3Efig3e-freq-increase-when-stable
    From the paper

    In Cs + , the mean percent of temperature-stable cycles in which frequency increased in Cs + (27.6±6%) was significantly higher than in control (14.1±5%) ( Figure 3E , paired Student’s t-test, N=21, p<0.001)

    Reported statistics
    • paired Student's t-test, p < 0.001 (n = 21 experiments)
    Result

    Centred window reading, percent of stable cycles with a frequency increase, 26.9 +- 6.2 in Cs+ and 13.2 +- 5.4 in saline, higher in Cs+ in 20 of 21, paired t p = 3e-09; the other six readings give 25.1 to 27.3 against 11.2 to 13.4, 20 of 21 and p < 2e-07 each.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • Stable cycles are those with a smoothed temperature change within +-0.01 C per cycle in the window reading, as the deposited code and the Figure 3A legend ('change less than 0.01 C/pyloric cycle') have it; the step and cooling readings count every cycle with a change <= 0.01 C as stable, as the Methods and the claims file header say.
    • The Timings windows end at the 21 C hold, so O3 (b) extends each window to the first cycle back within 0.3 C of 11 C, the cooling that precedes the solution change (Methods, Temperature protocol).
    • Smoothing runs over the whole recording, across condition boundaries, as the deposited code does; smoothing within the window is shown as a variant.
  • Reproduced

    The percent of temperature-increasing cycles with a frequency decrease differed by condition; it was higher in Cs+ and in Cs+ + PTX than in saline, with no difference between Cs+ and Cs+ + PTX.

    Centred window reading over the paper's six, percent of warming cycles with a frequency decrease, saline 2.0…

    Results, In Cs+, follower neurons determined frequency-temperature sensitivity, paragraph 2; Figure 4Dfig4d-ptx-keeps-decrease-while-warming
    From the paper

    The probability of frequency decrease while temperature increased was lower in control than in either Cs + or Cs + +PTX ( Figure 4D ), with no difference between Cs + and Cs + +PTX

    Reported statistics
    • one-way repeated measures ANOVA, F(2,10) = 13.077, p = 0.002 (n = 6 experiments)
    Result

    Centred window reading over the paper's six, percent of warming cycles with a frequency decrease, saline 2.0, Cs+ 28.9, Cs+ + PTX 30.8; F(2,10) = 13.00, p = 0.0017; saline below Cs+ (multcompare p = 0.023, classic 0.004) and below Cs+ + PTX (0.004, 0.003); Cs+ against Cs+ + PTX p = 0.965 and 0.953. All six O3 readings give the same pattern (condition p <= 0.002, both Cs+ conditions above saline at p <= 0.031, Cs+ against Cs+ + PTX p >= 0.87).

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The six are the paper's, including the two preparations of 981_035.
  • Reproduced

    The percent of temperature-stable cycles with a frequency increase differed between all three conditions, lowest in saline, middle in Cs+ and highest in Cs+ + PTX.

    Centred window reading over the six, percent of stable cycles with a frequency increase, saline 7.5 < Cs+ 24.6…

    Results, In Cs+, follower neurons determined frequency-temperature sensitivity, paragraph 2; Figure 4Efig4e-stable-increase-ordering
    From the paper

    the probability of frequency increase while temperature was stable was significantly different between all three conditions... control was lowest, Cs + was in the middle, and Cs + +PTX was greatest

    Reported statistics
    • one-way repeated measures ANOVA, F(2,10) = 69.572, p < 0.001 (n = 6 experiments)
    Result

    Centred window reading over the six, percent of stable cycles with a frequency increase, saline 7.5 < Cs+ 24.6 < Cs+ + PTX 38.0; F(2,10) = 79.5, p = 7e-07; all three Tukey pairs significant under both readings (p <= 0.012). All six O3 readings agree (pairs p <= 0.015).

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The six are the paper's, including the two preparations of 981_035.
  • Reproduced

    At 11 degrees C the PD burst was modestly shorter in Cs+ (144 ms) than in saline (164 ms).

    First to last PD spike, mean over the first 11 C hold, 164 +- 36 ms in saline and 145 +- 19 ms in Cs+ over 20…

    Results, Phase of PD and LP advanced in Cs+, paragraph 1; Figure 5Bfig5b-pd-burst-shorter
    From the paper

    The time of PD bursting was significantly but modestly shorter in Cs + ( Figure 5B , saline ... 164±34 ms, Cs + ... 144±18 ms)

    Reported statistics
    • Wilcoxon signed-rank test, p = 0.019 (n = 21 experiments)
    Result

    First to last PD spike, mean over the first 11 C hold, 164 +- 36 ms in saline and 145 +- 19 ms in Cs+ over 20 experiments, Wilcoxon p = 0.012, shorter in Cs+ in 15. O4 reading (b), every cycle of the first holding period, gives 165 and 146 ms (p = 0.014); the deposited code's measure, period times PD OFF phase, 164 and 145 ms (p = 0.017); with the gap cycles kept 164 and 145 ms (p = 0.012).

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • 20 of 21 experiments (969_070 has no 11 C Cs+ cycle).
    • O4 reading (b) takes every cycle of the first holding period, from the first cycle of the condition window within 1 C of 11 C (a standard bound) to the onset of the warming toward 13 C, whatever its temperature. The onset is traced back, by the paper's increasing-temperature rule (a smoothed rise above 0.01 C per cycle), from the rise that leaves the band within 0.3 C of 11 C for the last time before 12.7 C is reached, so that a brief rise during the hold does not end the holding period (a standard choice).
  • Reproduced

    At 11 degrees C, PD OFF phase was advanced in Cs+ (0.12) compared with saline (0.19).

    PD OFF phase at 11 C, 0.191 +- 0.044 in saline and 0.122 +- 0.027 in Cs+ over 20 experiments, paired t = 7.90…

    Results, Phase of PD and LP advanced in Cs+, paragraph 1; Table 1; Figure 5Ctable1-pd-off-advanced
    From the paper

    the phase of PD OFF (percentage of period at which PD stops firing) was significantly advanced in Cs + compared to control

    Reported statistics
    • paired Student's t-test, p < 0.001 (n = 21 experiments)
    Result

    PD OFF phase at 11 C, 0.191 +- 0.044 in saline and 0.122 +- 0.027 in Cs+ over 20 experiments, paired t = 7.90, p = 2e-07, lower in Cs+ in all 20; O4 reading (b) 0.191 and 0.123 (20 experiments); gap cycles kept 0.198 and 0.126.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • Onsets and offsets are those of the longest run of spikes with gaps of at most 0.11 s in the cycle (deposited Phase_Calc.m), which settles O6.
    • O4 reading (b) takes every cycle of the first holding period, from the first cycle of the condition window within 1 C of 11 C (a standard bound) to the onset of the warming toward 13 C, whatever its temperature. The onset is traced back, by the paper's increasing-temperature rule (a smoothed rise above 0.01 C per cycle), from the rise that leaves the band within 0.3 C of 11 C for the last time before 12.7 C is reached, so that a brief rise during the hold does not end the holding period (a standard choice).
  • Reproduced

    At 11 degrees C, LP ON phase was advanced in Cs+ (0.29) compared with saline (0.40).

    LP ON phase at 11 C, 0.398 +- 0.049 in saline and 0.289 +- 0.051 in Cs+ (20 experiments), paired t p = 2e-07…

    Results, Phase of PD and LP advanced in Cs+, paragraph 1; Table 1; Figure 5Ctable1-lp-on-advanced
    From the paper

    LP onset, which follows PD offset, was also phase advanced in Cs + conditions compared to control

    Reported statistics
    • paired Student's t-test, p < 0.001 (n = 21 experiments)
    Result

    LP ON phase at 11 C, 0.398 +- 0.049 in saline and 0.289 +- 0.051 in Cs+ (20 experiments), paired t p = 2e-07, lower in Cs+ in 19; reading (b) 0.398 and 0.290 (20 experiments); gap cycles kept 0.404 and 0.295.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • O4 reading (b) takes every cycle of the first holding period, from the first cycle of the condition window within 1 C of 11 C (a standard bound) to the onset of the warming toward 13 C, whatever its temperature. The onset is traced back, by the paper's increasing-temperature rule (a smoothed rise above 0.01 C per cycle), from the rise that leaves the band within 0.3 C of 11 C for the last time before 12.7 C is reached, so that a brief rise during the hold does not end the holding period (a standard choice).
  • Reproduced

    At 11 degrees C, LP OFF phase was advanced in Cs+ (0.56) compared with saline (0.66).

    LP OFF phase at 11 C, 0.664 +- 0.053 in saline and 0.565 +- 0.056 in Cs+ (20 experiments), paired t p = 1e-07…

    Results, Phase of PD and LP advanced in Cs+, paragraph 2; Table 1; Figure 5Ctable1-lp-off-advanced
    From the paper

    LP OFF was also significantly advanced in Cs +

    Reported statistics
    • paired Student's t-test, p < 0.001 (n = 21 experiments)
    Result

    LP OFF phase at 11 C, 0.664 +- 0.053 in saline and 0.565 +- 0.056 in Cs+ (20 experiments), paired t p = 1e-07, lower in Cs+ in 20; reading (b) 0.664 and 0.565; gap cycles kept 0.671 and 0.571.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • O4 reading (b) takes every cycle of the first holding period, from the first cycle of the condition window within 1 C of 11 C (a standard bound) to the onset of the warming toward 13 C, whatever its temperature. The onset is traced back, by the paper's increasing-temperature rule (a smoothed rise above 0.01 C per cycle), from the rise that leaves the band within 0.3 C of 11 C for the last time before 12.7 C is reached, so that a brief rise during the hold does not end the holding period (a standard choice).
  • Reproduced

    At 11 degrees C, PY ON (0.58 against 0.60) and PY OFF (0.87 against 0.90) phases did not differ between saline and Cs+.

    Over the 12 experiments with PY phases in both conditions, PY ON is 0.603 +- 0.094 in saline and 0.598 +…

    Results, Phase of PD and LP advanced in Cs+, paragraph 2; Table 1table1-py-phase-unchanged
    From the paper

    PY ON and PY OFF were not significantly different between Cs + and control

    Reported statistics
    • PY ON: paired Student's t-test, p = 0.86 (n = 12 experiments)
    • PY OFF: Wilcoxon signed-rank test, p = 0.91 (n = 12 experiments)
    Result

    Over the 12 experiments with PY phases in both conditions, PY ON is 0.603 +- 0.094 in saline and 0.598 +- 0.104 in Cs+ (difference 0.006, paired t p = 0.846) and PY OFF 0.884 +- 0.204 and 0.897 +- 0.188 (difference -0.013, Wilcoxon p = 0.677); reading (b) p = 0.847 and 0.970, gap cycles kept p = 0.727 and 0.424. Neither of the paper's tests finds a difference.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • O4 reading (b) takes every cycle of the first holding period, from the first cycle of the condition window within 1 C of 11 C (a standard bound) to the onset of the warming toward 13 C, whatever its temperature. The onset is traced back, by the paper's increasing-temperature rule (a smoothed rise above 0.01 C per cycle), from the rise that leaves the band within 0.3 C of 11 C for the last time before 12.7 C is reached, so that a brief rise during the hold does not end the holding period (a standard choice).
  • Reproduced

    The phase delay between PD OFF and LP ON was smaller in Cs+ (0.17) than in saline (0.21), so LP ON advanced more than the PD OFF advance explains.

    Per-cycle LP ON minus PD OFF at 11 C, 0.207 +- 0.064 in saline and 0.167 +- 0.044 in Cs+ (20 experiments)…

    Results, Phase of PD and LP advanced in Cs+, paragraph 1; Figure 5Dfig5d-pdoff-lpon-delay-smaller
    From the paper

    the delay between PD OFF and LP ON phase was significantly smaller in Cs + compared to control ( Figure 5D , saline ... 0.21±0.06, Cs + ... 0.17±0.04)

    Reported statistics
    • paired Student's t-test, p = 0.0048 (n = 21 experiments)
    Result

    Per-cycle LP ON minus PD OFF at 11 C, 0.207 +- 0.064 in saline and 0.167 +- 0.044 in Cs+ (20 experiments), paired t p = 0.004; the difference of the two means gives the same values (p = 0.004); reading (b) 0.207 and 0.167, p = 0.004; gap cycles kept 0.206 and 0.169, p = 0.008.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • O4 reading (b) takes every cycle of the first holding period, from the first cycle of the condition window within 1 C of 11 C (a standard bound) to the onset of the warming toward 13 C, whatever its temperature. The onset is traced back, by the paper's increasing-temperature rule (a smoothed rise above 0.01 C per cycle), from the rise that leaves the band within 0.3 C of 11 C for the last time before 12.7 C is reached, so that a brief rise during the hold does not end the holding period (a standard choice).
  • Reproduced

    LP duty cycle did not differ between saline and Cs+ at 11 degrees C.

    LP duty cycle at 11 C, 0.267 +- 0.057 in saline and 0.276 +- 0.045 in Cs+ (difference -0.009, 20 experiments)…

    Results, Phase of PD and LP advanced in Cs+, paragraph 2lp-duty-cycle-preserved
    From the paper

    LP OFF was also significantly advanced in Cs + , and subsequently duty cycle (percent of the period a neuron is firing) was preserved (paired Student’s t-test, N=21, p=0.448)

    Reported statistics
    • paired Student's t-test, p = 0.448 (n = 21 experiments)
    Result

    LP duty cycle at 11 C, 0.267 +- 0.057 in saline and 0.276 +- 0.045 in Cs+ (difference -0.009, 20 experiments); paired t p = 0.445, so the paper's test does not find a difference (paper p = 0.448). Reading (b) p = 0.433, gap cycles kept p = 0.449.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • O4 reading (b) takes every cycle of the first holding period, from the first cycle of the condition window within 1 C of 11 C (a standard bound) to the onset of the warming toward 13 C, whatever its temperature. The onset is traced back, by the paper's increasing-temperature rule (a smoothed rise above 0.01 C per cycle), from the rise that leaves the band within 0.3 C of 11 C for the last time before 12.7 C is reached, so that a brief rise during the hold does not end the holding period (a standard choice).
  • Reproduced

    In cycles of matched period between saline at 11 degrees C and Cs+, PD bursts were 51 ms shorter in Cs+ while LP fired 91 ms earlier and PY latency did not change (1.9 ms), and the PD offset advance did not correlate with the LP onset advance.

    Reading (a), the Cs+ holding temperature nearest in period to the saline 11 C mean (21 experiments), PD bursts…

    Results, Phase of PD and LP advanced in Cs+, paragraph 3matched-period-lp-earlier
    From the paper

    Although PD burst duration was only 51±30 ms shorter in Cs + , LP fired 91±68 ms earlier. Conversely, PY latency did not change in these matched frequency samples (1.9±100 ms earlier). There was no correlation between how advanced PD’s offset was between control and Cs + conditions and how much LP’s onset advanced in these matched period samples (Pearson correlation; r(21)=0.26, p=0.2928)

    Reported statistics
    • correlation of PD offset advance with LP onset advance: Pearson correlation, r(21) = 0.26, p = 0.2928
    Result

    Reading (a), the Cs+ holding temperature nearest in period to the saline 11 C mean (21 experiments), PD bursts 50 +- 34 ms shorter in Cs+, LP onset 71 +- 65 ms earlier, PY onset -33 +- 110 ms (12 experiments with PY), all within tolerance, LP advance larger than PD shortening, and PD offset advance against LP onset advance r = 0.10, p = 0.675 over 21 pairs, not significant. Reading (b), Cs+ cycles within 2% of each experiment's saline 11 C mean period (19 experiments), gives 63 +- 35, 95 +- 71 and 16 +- 110 ms (11 with PY), r = 0.18, p = 0.461, and also matches. With the gap cycles kept, reading (b) gives the same (63 and 96 ms, r = 0.10, p = 0.687) and reading (a) fails (LP advance 39 ms, below the PD shortening of 51 ms, r = 0.50, p = 0.020), so the outcome does not rest on leaving them out. The deposited LPAdvanceSamePeriod.mat, from code that is not deposited and on a different set of experiments, gives the paper's 51 +- 30, 91 +- 68 and 1.9 ms and r = 0.26, p = 0.2928 over 18 pairs.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The 11 C value is from the first 11 C hold of each condition (O2). The return to 11 C, the O2 variant, lies outside every deposited condition window, during the solution change, and is not used; the deposited code's reading (every 11 C cycle of the window) selects the same cycles.
    • The matched sets are the claims file's readings; the paper's own matching (LPAdvanceSamePeriod.mat) uses 21 experiments that include 969_120, which has no spike file, and 969_154, and lack 965_106 and 981_010.
  • Reproduced

    In saline, LP OFF phase advanced modestly with temperature, by 0.07 per 10 degrees C; all other phases were constant.

    O4 reading (a), line through the six per-temperature means, LP OFF in saline advances 0.071 +- 0.065 per 10 C…

    Results, Phase constancy with increasing temperature was reduced by Cs+, paragraph 1; Figure 6A and 6Bfig6a-lp-off-advances-saline
    From the paper

    In control conditions, LP OFF modestly advanced with temperature, with a mean advance of 0.07±0.07 per 10°C (Wilcoxon signed-rank test, N=21, p<0.01)

    Reported statistics
    • Wilcoxon signed-rank test, p < 0.01, Bonferroni, 10 tests-corrected (n = 21 experiments)
    Result

    O4 reading (a), line through the six per-temperature means, LP OFF in saline advances 0.071 +- 0.065 per 10 C over 21 experiments, Wilcoxon p times 10 = 0.0001, negative slope. Reading (b), every cycle of the condition window, 0.064, t-test adjusted p = 0.0005; with the gap cycles kept 0.076, p = 0.0001. The deposited per-experiment phases, fitted and tested as the deposited script does, give 0.074 +- 0.075, Wilcoxon adjusted p = 0.0002.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The line is fitted against the nominal temperatures 11 to 21 C under reading (a), as the deposited MakePaperFigures_Clean.m does (fitlm([11:2:21], ...)).
  • Reproduced

    In Cs+, LP ON and LP OFF advanced with temperature, by 0.05 and 0.14 per 10 degrees C.

    In Cs+, under O4 reading (a), LP ON advances 0.053 +- 0.052 per 10 C (Wilcoxon adjusted p = 0.0003) and LP OFF…

    Results, Phase constancy with increasing temperature was reduced by Cs+, paragraph 2; Figure 6A and 6Crests on an assumptionfig6a-lp-advances-cs
    From the paper

    In Cs + , LP ON and LP OFF advanced with temperature, with a mean advance of 0.05±0.05 per 10°C and 0.14±0.09 per 10°C respectively (Wilcoxon signed-rank test, N=21, p<0.01)

    Reported statistics
    • Wilcoxon signed-rank test, p < 0.01, Bonferroni, 10 tests-corrected (n = 21 experiments)
    Result

    In Cs+, under O4 reading (a), LP ON advances 0.053 +- 0.052 per 10 C (Wilcoxon adjusted p = 0.0003) and LP OFF 0.140 +- 0.096 (adjusted p < 0.0001), both within tolerance and below 0.01; reading (b), every cycle of the window, gives 0.047 and 0.122 (t-test adjusted p = 0.0020 and < 0.0001, the test Shapiro-Wilk chooses; Wilcoxon 0.0005 and < 0.0001). The outcome rests on leaving out the cycles that the deposited outlier removal leaves spanning two or more bursts. With them kept, as the deposited code does, LP ON advances 0.010 +- 0.202 with adjusted p = 0.029 and LP OFF 0.096 +- 0.224 with p = 0.004, so only LP OFF would hold; the gap cycles, whose phases are divided by the period of a single cycle, widen the spread of the LP ON slopes about fourfold. The authors' own per-experiment phases (SummaryStatistics.mat TotalLPON_E and TotalLPOFF_E), fitted and tested as the deposited MakePaperFigures_Clean.m does, give LP ON 0.054 +- 0.055 per 10 C with Wilcoxon adjusted p = 0.0004 and LP OFF 0.140 +- 0.099 with p < 0.0001, as leaving the gap cycles out does. The port's outlier removal is printed beside the deposited extractBurstFrequency_Final.m lines it follows.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • O4 reading (b) fits a line through the phase of every cycle of the condition window against its temperature; the fit through the cycles within 0.3 C of a target is shown as a variant (b_hold).
  • Reproduced

    PD and PY phases were constant with temperature in both saline and Cs+.

    Slopes of PD OFF, PY ON and PY OFF in each condition, with the test chosen by Shapiro-Wilk on the slopes, have…

    Results, Phase constancy with increasing temperature was reduced by Cs+, paragraph 2; Figure 6Afig6a-pd-py-phase-constant
    From the paper

    PD and PY phase constancy was not significantly altered in either condition

    Result

    Slopes of PD OFF, PY ON and PY OFF in each condition, with the test chosen by Shapiro-Wilk on the slopes, have adjusted p of 1.0, 0.47 and 1.0 in saline and 0.13, 1.0 and 0.34 in Cs+ under reading (a), and >= 0.08 under every other reading (b, b_hold, gaps kept); none is below 0.05. Mean advances per 10 C are 0.004, -0.053, -0.010 (saline) and 0.017, 0.038, 0.082 (Cs+). LP ON in saline, reported the same way, has adjusted p = 0.35 (advance 0.023). The deposited per-experiment phases, fitted and tested as the deposited script does (its fixed choice of test, PY only for the 11 experiments with a complete saline PY ON row), give adjusted p >= 0.056 for these six slopes and 0.40 for LP ON in saline.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • PY slopes use 13 experiments in saline (969_088 has PY spikes in saline only) and 12 in Cs+; the paper gives N=12 for PY.
    • The normality decision is made here by Shapiro-Wilk, as the Methods say; the deposited script hard-codes it (NormalityCheck), and gives the same choice for 9 of the 10 tests. Both tests are printed.
    • O4 reading (b) fits a line through the phase of every cycle of the condition window against its temperature; the fit through the cycles within 0.3 C of a target is shown as a variant (b_hold).

Partially reproduced1

  • Partially reproduced

    The frequency change from 11 to 21 degrees C differed by condition; it was smaller in Cs+ than in saline or in Cs+ + PTX, with no difference between saline and Cs+ + PTX.

    With the criterion's 0.3 C rule the two preparations of 981_035 (its PD and PD2 trains) have no 21 C value…

    Results, In Cs+, follower neurons determined frequency-temperature sensitivity, paragraph 1; Figure 4Cverifier disagreed at firstrests on an assumptionfig4c-ptx-restores-frequency-change
    From the paper

    change in frequency in Cs + was significantly lower than in either control or Cs + +PTX ( Figure 4C ) with no significant difference between control and Cs + +PTX

    Reported statistics
    • one-way repeated measures ANOVA, F(2,10) = 12.272, p = 0.002 (n = 6 experiments)
    Result

    With the criterion's 0.3 C rule the two preparations of 981_035 (its PD and PD2 trains) have no 21 C value, their top hold being at 20.7 C, so only 4 experiments are complete and the condition effect is not significant, F(2,6) = 4.21, p = 0.072, with no pair significant (p >= 0.06). Taking their top hold with a 0.5 C margin (assumed, below), the paper's six give F(2,10) = 10.43, p = 0.0036; saline 0.92, Cs+ 0.38, Cs+ + PTX 0.73 Hz. Cs+ is below saline under both Tukey readings (multcompare p = 0.025, classic p = 0.003) and saline against Cs+ + PTX is not significant (0.114, 0.307), but Cs+ is below Cs+ + PTX only under the classic reading (p = 0.036), not under the multcompare reading the deposited code uses (p = 0.106). The full pattern thus holds only with a margin wider than the criterion's and under one of the two post hoc readings, so the outcome is partial. Keeping the gap cycles gives F(2,10) = 10.38 and the same pattern. The deposited SummaryStatisticsPTX values give the paper's F(2,10) = 12.27, p = 0.002, and all three criterion pairs as stated under both readings.

    Deviations from the paper’s method
    • Per-cycle measures are computed with a Python port of the deposited MATLAB code (extractBurstFrequency_Final.m, Phase_Calc.m with 0.11 s, CalculateFrequencyPhaseEtc.m), which also fixes details the paper leaves open (the outlier-cycle removal, the 1/8 Hz cycle filter, the condition windows from the Timings table and fileTimes). The cycles that the deposited outlier removal leaves spanning two or more bursts while keeping their own period (1.6% of cycles) are left out of the hold means and phases. This is an assumption, since the deposited code keeps them; without them the phases agree with the deposited SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, and up to 0.85 in single values) and the frequencies to 0.003 to 0.006 either way. Keeping them is shown as a variant.
    • The six experiments are the paper's, 969_147, 969_150, 969_152, 969_154 and the two preparations of 981_035 (its PD and PD2 trains, SummaryStatisticsPTX.mat BurstAvgs_981_035 and BurstAvgs_981_035_2), which do not burst together.
    • For 969_147 the Cs+ protocol is Cs_1 (it matches the deposited summary); Cs_2 is a second, shorter Cs+ window.
    • Assumption. The 21 C value of an experiment whose top hold did not reach 21 +- 0.3 C (981_035, 20.7 C) is the mean over cycles within 0.5 C of 21 C. The paper gives 0.3 C for the holding temperatures (Results, The steady-state frequency increase, paragraph 3) and reports N=6 with F(2,10), so it entered 981_035 with some 21 C value; the deposited summary has one (measured mean 20.70 C). The paper does not say how; this is a question for the authors.

Blocked4

  • Blocked

    At 11 degrees C and -110 mV, Ih in PD and LP cells was 1.5 nA in saline and 0.23 nA in Cs+, a reduction of 93% (4 PD and 3 LP cells, paired t-test p = 0.0005).

    VoltageClampData.mat holds one trial per experiment (the first, saline or TTX+PTX), so no Cs+ voltage-clamp…

    Data missing from the datasetResults, The steady-state frequency increase in response to elevated temperature was decreased by Cs+, paragraph 1; Figure 1-figure supplement 1A and 1Cfigs1-ih-reduced-11c
    From the paper

    At 11°C and –110 mV, I h was 1.5±0.83 nA in saline and 0.23±.5 nA in Cs + , a reduction of 93±30% (4 PD cells, 3 LP cells, paired Student’s t-test; p=0.0005)

    Reported statistics
    • paired Student's t-test, p = 5 × 10⁻⁴ (n = 4 PD and 3 LP cells)
    Result

    VoltageClampData.mat holds one trial per experiment (the first, saline or TTX+PTX), so no Cs+ voltage-clamp trial of the 7 cells clamped at 11 C is in the dataset. VoltageClampTraceData.mat holds saline and Cs+ traces of the four example cells of Figure 1-figure supplement 1, two at 11 C (981_065 PD, 981_064 LP). Their steps last 12.000 s at -110 mV. Readings (a) and (b) give negative Ih in Cs+ and in the saline LP cell, because a faster inward current relaxes in the first few hundred ms of the step; reading (c), the least inward current in the first second minus the steady state, gives 1.70 and 0.98 nA in saline and -0.07 and -0.07 nA in Cs+, close to the script's by-eye values for these cells (1.88 and 0.50, -0.17 and -0.30). Two cells cannot test the claim. The deposited script's per-cell values, typed into MakePaperFigures_Clean.m from readings judged by eye (its comment), give 1.55 +- 0.83 nA in saline, 0.25 +- 0.49 nA in Cs+, a 94 +- 32% reduction and paired t p = 0.0005, the paper's numbers; they are shown, not tested, since the traces they were read from are not deposited.

  • Blocked

    At 21 degrees C and -110 mV, Ih was 3.2 nA in saline and 0.6 nA in Cs+, a reduction of 78% (5 LP and 3 PD cells, paired t-test p = 0.02).

    As figs1-ih-reduced-11c. The two 21 C cells with deposited saline and Cs+ traces (970_093 PD, 981_033 LP)…

    Data missing from the datasetResults, The steady-state frequency increase in response to elevated temperature was decreased by Cs+, paragraph 1; Figure 1-figure supplement 1B and 1Dfigs1-ih-reduced-21c
    From the paper

    At 21°C and –110 mV, I h was 3.2±2.3 nA in saline and 0.6±.8 nA in Cs + , a reduction of 78±20% (5 LP cells, 3 PD cells, paired Student’s t-test; p=0.02)

    Reported statistics
    • paired Student's t-test, p = 0.02 (n = 5 LP and 3 PD cells)
    Result

    As figs1-ih-reduced-11c. The two 21 C cells with deposited saline and Cs+ traces (970_093 PD, 981_033 LP) give, under reading (c), 2.22 and 2.07 nA in saline and -0.02 and 0.05 nA in Cs+ (script values 2.13 and 2.18, 0.13 and 0.14). The script's typed per-cell values for the 8 cells give 3.17 +- 2.26 nA in saline, 0.58 +- 0.79 nA in Cs+, 78 +- 19% and p = 0.021, the paper's numbers, shown and not tested.

  • Blocked

    In the two-saline experiments the Q10 of the first protocol (2.0) did not differ from that of the second (1.8).

    The criterion judges on Q10 under reading (a), a fit to the six holding-temperature means, which needs the…

    Data missing from the datasetResults, The steady-state frequency increase, paragraph 4; Figure 1E legendfig1e-two-saline-q10-same
    From the paper

    the mean Q 10 of the first temperature increase (2.0±0.4) was not significantly different than the mean Q 10 of the second temperature increase (1.8±0.4)

    Reported statistics
    • paired Student's t-test, p = 0.14 (n = 6 experiments)
    Result

    The criterion judges on Q10 under reading (a), a fit to the six holding-temperature means, which needs the spike data of the control experiments; five of the six are not deposited. Variants that the deposited table allows find no difference, deposited Q10 (the deposited code's reading b) 1.98 +- 0.40 against 1.83 +- 0.43, paired t p = 0.144, and reading (c) from the table's 11 and 21 C means 1.92 against 1.79, p = 0.133.

  • Blocked

    The saline Q10 did not differ between experiments with two saline protocols and those with one saline and one Cs+ protocol.

    Blocked as fig1e-two-saline-q10-same, the control experiments' Q10 under reading (a) cannot be computed.

    Data missing from the datasetResults, The steady-state frequency increase, paragraph 4; Figure 1E legendfig1e-saline-q10-same-across-designs
    From the paper

    Q 10 was also not significantly different between the mean Q 10 of the experiments with two saline temperature changes those that experienced one saline and one Cs + temperature change (two-sample t-test, p=0.26)

    Reported statistics
    • two-sample t-test, p = 0.26 (n = 6 two-saline and 21 saline and Cs+ experiments)
    Result

    Blocked as fig1e-two-saline-q10-same, the control experiments' Q10 under reading (a) cannot be computed. Variants, two-sample t-test of the deposited control Q10 values (mean of each experiment's two) against the 21 saline Q10 values computed here under reading (b), p = 0.244 (first protocol only p = 0.110, 12 pooled p = 0.150); against the deposited saline Q10 values p = 0.259, the paper's 0.26.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Selection not documentedThe picrotoxin results of Figure 4C to 4E (N=6 experiments, F(2,10)) include two preparations recorded at the same time with one thermocouple (981_035, spike trains PD and PD2). The paper does not say that preparations were recorded in pairs, so a reader cannot tell that two of the six share one temperature record.#
  • Methods not availableQuestion for the authors. The two preparations of 981_035 never came within 0.3 C of 21 C (their top hold is at 20.7 C), yet they enter the 11 to 21 C frequency change of Figure 4C. Which cycles formed their 21 C value? This attempt used cycles within 0.5 C of 21 C; with the 0.3 C rule of the Results only four experiments are complete and the effect is not significant (p = 0.072). Which post hoc test was used, MATLAB multcompare on the fitrm model (as the deposited script) or a classic Tukey HSD on the ANOVA error term? Here Cs+ against Cs+ + PTX is significant under the second (p = 0.036) and not under the first (p = 0.106).#
  • Published code disagreesThe deposited code, run on the deposited spike files, gives per-experiment values close to the deposited summary files but not equal to them. Its outlier removal (extractBurstFrequency_Final.m) deletes a cycle's start with its frequency, so the cycle before keeps its own period while its phases run to a start two or more bursts later (1.6% of cycles; an LP ON phase of 32 in 969_128). With those cycles left out, the phases agree with SummaryStatistics.mat to a median of 0.0004 to 0.0009 (0.0035 to 0.0048 with them, up to 0.85 in single values), so the summaries were most likely made by a version of the code that is not deposited; the frequencies differ by a median of 0.003 to 0.006 Hz either way, up to 0.21 Hz at irregular 21 C holds. 969_068 has an 11 C Cs+ frequency that the summary lacks, and 981_035 none at 21 C where the summary has one. LPAdvanceSamePeriod.mat, behind the matched-period numbers, has no code at all and covers a different set of 21 experiments, including 969_120, which has no spike file.#
  • Methods not availableQuestion for the authors. The deposited extractBurstFrequency_Final.m removes outlier cycles by deleting a burst's start with its frequency, which leaves the previous cycle spanning two or more bursts with its own period. Were those cycles left out of the phase means of SummaryStatistics.mat, or were the phases computed otherwise? This attempt leaves them out, which brings its phases to within a median of 0.0004 to 0.0009 of the deposited ones. With them kept, the LP ON slope in Cs+ (Figure 6A, 6C) has a Bonferroni-adjusted Wilcoxon p of 0.029; without them, 0.0003; on the deposited per-experiment phases of SummaryStatistics.mat, 0.0004.#

Questions about the claims 1

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • openasked 2026-11-25about fig1f-two-saline-frequency-change-same

    The claims file (header, data, and the statement of this claim) describes the control experiments as "two consecutive saline step protocols". The paper says "two consecutive temperature changes in saline" and does not say both were steps. Should the statement and the header say temperature changes, as the paper does, and should the criterion say how the 11 and 21 degrees C values are formed when the second change is a ramp, which has no 11 degrees C hold? The same wording bears on fig1e-two-saline-q10-same and fig1e-saline-q10-same-across-designs.

    Passage. Results, The steady-state frequency increase in response to elevated temperature was decreased by Cs+, paragraph 4: "we performed two consecutive temperature changes in saline. The mean difference in frequency between 21°C and 11°C for the first (0.9±0.3 Hz) and second temperature changes (0.8±0.3 Hz) were not significantly different (Figure 1F)."

    Why it matters. Raised by the round-1 verifier. The deposited ControlTable (SummaryStatistics.mat) gives the second protocol as a ramp in three of the six experiments (965_146, 981_025, 982_005). In this attempt the claim is tested on the table's per-experiment values, because five of the six experiments have no spike file, so the outcome does not change (paired t p = 0.137). It would matter for an attempt with the spike data, where a hold-based criterion cannot be applied to a ramp as written, and the two Q10 claims are blocked for that reason already.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Ih block and the temperature response of the pyloric rhythm (Schapiro et al. 2024)

Tests the findings of Schapiro, Rittenberg, Kenngott and Marder (2024) on Dryad dataset 1rn8pk129, which holds the PD, LP and PY spike times and the temperature of 25 Cancer borealis preparations recorded over temperature steps in saline, 5 mM Cs+ and Cs+ with picrotoxin, the authors' summary values and code, voltage-clamp files and seven raw recordings. It compares pyloric frequency, Q10, the non-monotonic jags while warming, and phases across conditions. The Ih measurements cannot be repeated, because the Cs+ voltage-clamp trials are not deposited. All files

Environment: Python 3.13, 15 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-25
    Agreed with 24 of 25 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1: the executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper's full text under paper/. The verifier read the Dryad API file lists of versions 310115 and 290160 and tested extract_bursts on a synthetic spike train; it could not read the deposited MATLAB scripts. It had no attempt record.
    • fig4c-ptx-restores-frequency-change: the verifier’s outcome was “Partially reproduced”. Under the criterion's 0.3 °C rule, 981_035 (both entries) has no 21 °C value: n=4, F(2,6)=4.20, p=0.072. Only with the author's 0.5 °C widening and the paper's six entries are all conditions met, and only under O5(b) (Cs+ vs Cs+ + PTX p=0.037; multcompare p=0.106). The five-preparation variant fails (cell 40). Problem 1, the widening departs from the criterion's 0.3 °C, though the paper's own N=6 includes 981_035, so it is a reasonable assumption; it also changes the other experiments' 21 °C values slightly, and even then the outcome depends on the O5 reading.
  • Round 2
    2026-11-25
    Agreed with 25 of 25 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2: the full executed notebook of the round-1 revision (conclusion cells and summary included), the helper module, the claims file, the README and the attempt record, with the paper under paper/. No finding was rated critical.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

Provenance

Attempt record
schapiro-2024-01
Paper
10.7554/elife.98844
Date
2026-11-25
Made by
An agent, run by CatalystNeuro
Dataset
DRYAD:1rn8pk129 (on DRYAD)
Version
310115 (doi:10.5061/dryad.1rn8pk129)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-19

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 20 findings reproduced, Schapiro et al. 2024

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/schapiro-2024/"><img src="https://encorescience.org/badge/papers/schapiro-2024.svg" alt="Encore: 20 findings reproduced, Schapiro et al. 2024"></a>

Or as Markdown:

[![Encore: 20 findings reproduced, Schapiro et al. 2024](https://encorescience.org/badge/papers/schapiro-2024.svg)](https://encorescience.org/papers/schapiro-2024/)

The same numbers are in this page’s JSON, under badge (how it is counted).