Datasets / DRYAD:1rn8pk129

Effects of Cs on temperature response of C. borealis pyloric rhythm

3.8 GB 50 files

Tested on dataset version 310115

20 findings reproduced from this dataset. Reproduced in full, by attempts an independent verifier checked.

View on DRYAD JSON

Papers tested on this dataset 1

Each opens the paper’s page, with every claim, its outcome and the notebook that tested it.

Ih block reveals separation of timescales in pyloric rhythm response to temperature changes in Cancer borealis

20 reproduced · 1 partially reproduced · 4 blocked
Attempt schapiro-2024-01 on version 310115
Verified2026-11-25

Open findings about the data 6

What the attempts that used this dataset found about the data themselves, for its owner and the archive, under the version of the dataset each was found on.

Dataset version 310115 · tested 2026-11-25 · 6 open findings

  • Data missingVoltageClampData.mat holds one trial per experiment, the first (saline or TTX+PTX), while its ConditionsKey lists 5 to 22 trials per experiment, 2 to 8 of them Cs+, and the README describes the array as trials x steps x time. No Cs+ voltage-clamp trial is deposited except the four example cells of VoltageClampTraceData.mat, so the Ih values of Figure 1-figure supplement 1 (7 cells at 11 C, 8 at 21 C) cannot be measured. The paper's Ih numbers come from per-cell values typed into MakePaperFigures_Clean.m from readings the script says were judged by eye. The file was 814 MB in version 290160 against 98 MB in 310115, so the earlier version may hold every trial; it was not read.#
    See the code that shows this finding in the executed notebook, with its output
    Found by the attempt on Schapiro et al. 2024 (schapiro-2024-01, 2026-11-25)
  • Data missingFive of the six two-saline control experiments of Figure 1E and 1F (965_129, 965_134, 965_139, 965_146, 982_005) have no spike and temperature file; only their per-experiment means are in ControlTable (SummaryStatistics.mat). The table's last two rows hold no experiment (their values are the column means and SDs), and it gives the second protocol as a ramp in three of the six (965_146, 981_025, 982_005).#
    See the code that shows this finding in the executed notebook, with its output
    Found by the attempt on Schapiro et al. 2024 (schapiro-2024-01, 2026-11-25)
  • Description missing981_035_SpikeAndTemp.mat holds two PD spike trains, PD and PD2, which the README does not describe. They do not burst together (PD2 burst starts fall within 50 ms of a PD burst start in 14% of cycles, against 13% with PD2 shifted by half a period) and run at different frequencies in every condition (saline 1.79 and 1.58 Hz, Cs+ 1.17 and 0.64 Hz), so they are two preparations recorded with one thermocouple, not two PD neurons of one preparation. SummaryStatisticsPTX.mat and SawtoothPTX.mat enter them as two experiments (BurstAvgs_981_035 and BurstAvgs_981_035_2); nothing in the files says that the second train is a second preparation.#
    See the code that shows this finding in the executed notebook, with its output
    Found by the attempt on Schapiro et al. 2024 (schapiro-2024-01, 2026-11-25)
  • OtherTempsub holds thermocouple dropouts far outside the protocol's 10 to 26 C, down to -46.7 C, in three files (969_070, 969_087, 969_089). All fall outside the condition windows, so the analyses here are unaffected; a user taking the whole trace would need to remove them.#
    See the code that shows this finding in the executed notebook, with its output
    Found by the attempt on Schapiro et al. 2024 (schapiro-2024-01, 2026-11-25)
  • OtherChecks that passed. The 21 saline and Cs+ experiments and the picrotoxin experiments are all deposited as spike files, with PD and LP in each and PY in 13; no PD spike train is deposited twice; spike times are in seconds, x_sub in minutes and the Timings windows hold the step protocols as the README says. In 969_113 the raw intracellular PD trace peaks at the deposited PD spike times and the raw temperature channel equals Tempsub, so spikes, temperature and raw traces share one clock there. In the other files the check of frequency against shifted temperature is weak (best shift within 0.5 min of 0 in 8 of 21, correlation lower at +3 min in 18 of 21); the close agreement of the values recomputed from spikes and temperature with the deposited summaries supports a shared clock. The voltage steps of VoltageClampTraceData.mat last 12.000 s as the paper says.#
    See the code that shows this finding in the executed notebook, with its output
    Found by the attempt on Schapiro et al. 2024 (schapiro-2024-01, 2026-11-25)
  • Description missingThree of the seven raw recordings (Raw_Expt_969_137.mat, Raw_Expt_981_007.mat, Raw_Expt_981_037.mat) have no spike file and no Timings table, and the README does not say which condition or protocol each holds. Raw_Expt_981_037.mat is the Cs+ + PTX example of Figure 4F,G only by the comment in MakePaperFigures_Clean.m, whose figure numbers run one ahead of the paper's ('Figure 5F,G: example of Jag in PTX').#
    Found by the attempt on Schapiro et al. 2024 (schapiro-2024-01, 2026-11-25)

Badges for this dataset

Encore: 20 findings reproduced, from DRYAD:1rn8pk129

It counts the findings reproduced in full from this dataset by attempts an independent verifier has checked, over every paper tested on it. To show it on the dataset’s own page, linked to this page:

<a href="https://encorescience.org/datasets/dryad/1rn8pk129/"><img src="https://encorescience.org/badge/dryad/1rn8pk129.svg" alt="Encore: 20 findings reproduced, from DRYAD:1rn8pk129"></a>

Or as Markdown:

[![Encore: 20 findings reproduced, from DRYAD:1rn8pk129](https://encorescience.org/badge/dryad/1rn8pk129.svg)](https://encorescience.org/datasets/dryad/1rn8pk129/)

The same numbers are in this page’s JSON, under badge (how it is counted).