Papers / Petersen et al. 2020 / Attempt petersen-2020-01

Petersen et al. 2020 · Neuron · attempt petersen-2020-01

Cooling of Medial Septum Reveals Theta Phase Lag Coordination of Hippocampal Cell Assemblies

Peter Petersen, György Buzsáki

Outcomes of 38 claims

  • 12 reproduced
  • 15 partially reproduced
  • 10 not reproduced
  • 1 blocked

Summary: Most of the paper's main findings on cooling the medial septum held in this data, but its claim that theta phase lags between place cells are preserved did not. Theta frequency fell with septal temperature (R = 0.79), place cell oscillation frequency fell with it, and time lags between place cell pairs lengthened. Choice errors rose about 2.3-fold, against the reported 3-fold. Phase lags were slightly larger during cooling, which may partly come from how each pair's lag is picked, and the size of the time compression could not be judged with this method. The hippocampal temperature control could not be tested because it is not in the dataset.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

An earlier attempt. Attempt petersen-2020-02 replaced it; the paper’s page shows the current outcomes. Its notebooks link to the entry as it is now; the attempt record is as it was.

Reading outcomes Respond to this attempt

Attempts 2

1 current, 1 replaced

Every attempt on the paper, each with the datasets it used and their versions. An attempt on a dataset replaces the one before it on that dataset; the paper’s page shows the current ones.

  1. Attempt 01Viewing2026-10-16replaced
    DANDI:000059 version 0.250624.0444
    38 claims · 11 findings about the data · protocol pilot-7
  2. Attempt 022026-11-15current
    DANDI:000059 version 0.261115.0311
    46 claims · 10 findings about the data · protocol pilot-15

Claims

Reproducing Petersen and Buzsaki (2020) from dandiset 000059 37 Open in Colab

Reproduced12

  • Reproduced

    A session holds about 40 control trials, then about 20 to 60 cooling trials and 20 to 80 recovery trials, 80 to 200 trials in all with a mean of 150.

    Over 45 BEH sessions the mean is 143.8 trials (80 to 204); medians of 39 pre-cooling, 47 cooling and 44…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; STAR Methods, Electrophysiological Recordingssession-structure
    From the paper

    After a block of control trials (~ 40 trials), dry ice was placed into the reservoir ... about 20 to 60 'cooling' trials), followed by recovery trials (20 to 80).

    Result

    Over 45 BEH sessions the mean is 143.8 trials (80 to 204); medians of 39 pre-cooling, 47 cooling and 44 post-cooling trials. 12 sessions have two cooling blocks, which the paper does not mention; in each the second block follows post-cooling trials, and the onset-aligned series stops before it. 'Cooling off' trials (median 14 per session) are counted in no state.

    Deviations from the paper’s method
    • 45 of the paper's 53 sessions.
  • Reproduced

    Theta frequency decreased linearly with MS temperature, down to 20 C (R = 0.81, P = 5.4e-48).

    With the code's aligned series, R = 0.789 (P = 2.8e-43, 198 positions) over 37 TEMP sessions under reading…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; Figure 2Gfig2g-theta-freq-temperature
    From the paper

    Theta frequency decreased linearly with MS temperature ( Figure 2g ; down to 20° C; R = 0.81; P = 5.4 × 10 −48 )

    Reported statistics
    • R = 0.81, p = 5.4 × 10⁻⁴⁸ (n = 53 sessions in 5 rats)
    Result

    With the code's aligned series, R = 0.789 (P = 2.8e-43, 198 positions) over 37 TEMP sessions under reading (a), and R = 0.758 (P = 3e-38) with the MS10 temperature curves under reading (b); both are within tolerance. Over single trials pooled R = 0.672, slope 0.065 Hz per C. Per rat R is 0.685 to 0.954.

    Deviations from the paper’s method
    • 37 sessions with a recorded temperature, where the paper used 53; the MS10 temperature in the dandiset is not a recording.
    • The theta electrode is the one flagged theta_reference in the files; the code's channel numbers could not be mapped to the files' electrodes.
  • Reproduced

    The relationship of theta frequency with MS temperature was more consistent across animals than that of theta power.

    In each of the four rats with a recorded temperature the frequency R is positive (0.685 to 0.954, every P…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; Figure 2Jfig2j-frequency-consistent-across-animals
    From the paper

    Theta frequency decreased linearly with MS temperature ... and this relationship was more consistent across animals than the effect on theta power

    Result

    In each of the four rats with a recorded temperature the frequency R is positive (0.685 to 0.954, every P below 1e-22), a range of 0.269, against a range of 0.722 for power (-0.346 to 0.376). The outcome rests on power varying across rats, since power shows no consistent effect (fig2h-theta-power-temperature).

    Deviations from the paper’s method
    • Four rats; MS10 has no recorded temperature.
  • Reproduced

    The error rate after cooling did not differ from the error rate before it.

    Post 6.49% against pre 6.67% (median difference -0.13 points, P = 0.837, 45 sessions); cooling against post P…

    Figure 6E (marked ns)fig6e-errors-recover
    From the paper

    Choice errors shown as boxplots constructed from all sessions. ** P < 10 −7 ns = nonsignificant.

    Result

    Post 6.49% against pre 6.67% (median difference -0.13 points, P = 0.837, 45 sessions); cooling against post P = 8e-08.

    Deviations from the paper’s method
    • The figure's 'ns' was read as pre against post.
  • Reproduced

    The worst memory performance occurred between trials 4 and 8 after the onset of cooling, when MS temperature reached its minimum, together with the largest decreases of theta frequency and power.

    The mean smoothed error series over 45 sessions peaks at trial 7 after onset (0.193, against 0.066 over the 40…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6Cfig6c-worst-trials-4-to-8
    From the paper

    The worst memory performance occurred between trials 4 and 8 after MS cooling, when the MS temperature reached its minimum, accompanied by the largest decreases of theta frequency and power

    Result

    The mean smoothed error series over 45 sessions peaks at trial 7 after onset (0.193, against 0.066 over the 40 trials before), the trial of the minimum mean temperature and theta frequency. The peak is narrow and the result fragile. A second rise reaches 0.186 at trial 20, and within single rats the mean peaks later, at trials 14 to 26. All 45 sessions contribute at every trial from 1 to 40.

  • Reproduced

    Running speed decreased relatively monotonically within a session, over the entire session.

    Speed falls with trial number in 44 of 45 sessions (median rho -0.452, P = 4e-13), in every rat; the aligned…

    Results, Effects of MS cooling on single neuron properties, paragraph 3; Figure 4E; Figure 6C; Figure S5D, Efig4e-speed-decreases-within-session
    From the paper

    Running speed decreased relatively monotonically within session ( Fig. 4e ; see also Fig. 5c ).

    Result

    Speed falls with trial number in 44 of 45 sessions (median rho -0.452, P = 4e-13), in every rat; the aligned mean falls from 86.0 to 73.7 cm/s.

  • Reproduced

    The theta oscillation frequency of putative fast spiking interneurons decreased with MS cooling, as did that of pyramidal cells, by about 14% on average, and pyramidal cells oscillated faster than interneurons.

    9.55 to 8.66 Hz (lower in 105 of 114, P = 8.7e-16), a 9.4% decrease against 8.8% for the LFP theta of the same…

    Results, Effects of MS cooling on single neuron properties, paragraph 1; Figure S2Dsuppl2d-interneuron-oscillation-slows
    From the paper

    Note that pyramidal neurons oscillate faster than interneurons and the theta frequency oscillation of both interneurons and pyramidal cells decreases with MS cooling by approximately 14% on average.

    Result

    9.55 to 8.66 Hz (lower in 105 of 114, P = 8.7e-16), a 9.4% decrease against 8.8% for the LFP theta of the same sessions; narrow units alone P = 3.1e-11.

    Deviations from the paper’s method
    • Putative interneurons typed here; the paper's fast-spiking interneurons come from CellExplorer.
  • Reproduced

    MS cooling decreased both the oscillation frequency of place cells (fp) and the LFP theta frequency in their fields (fLFP) by about the same degree, and both recovered (fLFP 8.4, 7.7, 8.5 Hz; fp 10.6, 9.5, 10.4 Hz before, during and after; n = 365).

    Over 361 fields (paper 365) all six means are within the paper's spreads; fp falls in 311 (P = 3.5e-44) and…

    Results, Effects of MS cooling on single neuron properties, paragraph 2; Figure 4Bfig4b-fp-flfp-decrease
    From the paper

    MS cooling decreased both f p and f LFP , measured within the place fields of neurons, by approximately the same degree ... Both values recovered after cooling.

    Reported statistics
    • comparison marked *** in Figure 4B: p < 5.9 × 10⁻⁸ (n = 365 place fields)
    Result

    Over 361 fields (paper 365) all six means are within the paper's spreads; fp falls in 311 (P = 3.5e-44) and fLFP in 352 (P = 1.2e-60), by 9.2% and 9.0%, and both recover. Each rat shows the same pattern and every session the decrease; in MS22-180720-110055 fp does not recover (9.92 Hz after, 10.15 Hz during cooling). Fields with at least 100 or 200 spikes per state give the same means.

    Deviations from the paper’s method
    • Fields by the automatic criteria of the Methods, from 11 sessions in 4 rats.
  • Reproduced

    Place field size was highly correlated before and during MS cooling (R = 0.91), and did not change.

    R = 0.8197 over 635 fields, at the edge of the tolerance (0.819).

    Results, Effect of MS cooling on place field features, paragraph 1; Figure 3Cfig3c-field-size-correlated
    From the paper

    Place field size does not change with MS cooling (R = 0.91).

    Result

    R = 0.8197 over 635 fields, at the edge of the tolerance (0.819). With at least 20 or 50 spikes per state R is 0.8348 and 0.8308, with at least 100 it is 0.8136, outside. Sizes do not differ (62.7 and 64.9 cm, P = 0.084).

    Deviations from the paper’s method
    • Field size from rate maps of each state (bins above 10% of the peak); the paper does not define it.
  • Reproduced

    The spatial scale of the population vector correlation of pyramidal cells was not affected by MS cooling.

    Median change 0.25 cm, P = 0.966 over 11 sessions (paper 21); scales 18.3 to 36.9 cm.

    Results, Effect of MS cooling on place field features, paragraph 3; Figure 3G, H, Ifig3hi-population-vector-unchanged
    From the paper

    Population vector correlation of pyramidal cells was not affected by MS cooling ( Fig. 3g , h ).

    Result

    Median change 0.25 cm, P = 0.966 over 11 sessions (paper 21); scales 18.3 to 36.9 cm.

    Deviations from the paper’s method
    • The decorrelation scale is computed within maze segments at 5 cm bins; 11 sessions.
  • Reproduced

    fp depended on running speed more strongly than fLFP, so fp - fLFP increased with speed, and fp during cooling was lower at all velocities.

    fp slope 0.0136 Hz per cm/s (P = 3.2e-12), fLFP 0.0061; difference 0.0074 (bootstrap interval 0.0040 to…

    Results, Effects of MS cooling on single neuron properties, paragraph 3; Figure 4G and 4Hfig4gh-fp-speed
    From the paper

    f p changes during MS cooling could not be explained by decreased running velocity of the rat because f p values during cooling were lower at all velocities ( Fig. 4g ).

    Result

    fp slope 0.0136 Hz per cm/s (P = 3.2e-12), fLFP 0.0061; difference 0.0074 (bootstrap interval 0.0040 to 0.0112). In the three speed bins from 60 to 120 cm/s with at least 10 fields fp is lower during cooling (P below 1e-5 each); below 60 cm/s too few fields had 50 spikes.

    Deviations from the paper’s method
    • Speed bins of 20 cm/s; the paper's bins are not stated.
  • Reproduced

    During MS cooling the theta time lags between place cell pairs increased compared with before and after cooling (P = 8.0e-5 and P = 0.00032), and did not differ between before and after (P = 0.79).

    Under reading (a), cooling against pre over 3136 pairs (30.5 against 28.5 ms, P = 1.14e-06) and against post…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 3; Figure 5Hfig5h-time-lags-increase
    From the paper

    During MS cooling, the time lags increased significantly ( Fig. 5h ; P < 10 −4 ; sign rank test; n = 10 sessions), whereas they were not different from each other during precooling and post-cooling sessions (P = 0.79)

    Reported statistics
    • pre against cooling: sign rank test, p = 8 × 10⁻⁵ (n = 10 sessions, 4 rats)
    • post against cooling: sign rank test, p = 3.2 × 10⁻⁴ (n = 10 sessions, 4 rats)
    • pre against post: sign rank test, p = 0.79 (n = 10 sessions, 4 rats)
    Result

    Under reading (a), cooling against pre over 3136 pairs (30.5 against 28.5 ms, P = 1.14e-06) and against post (P = 1.3e-10); pre and post do not differ (P = 0.0967). Reading (b) agrees (P = 0.023, 0.016 and 0.81), and so does the half-period window (P = 3.8e-22 and 2.0e-29).

    Deviations from the paper’s method
    • The legend's n = 10 sessions cannot give P = 8e-5 with a signed-rank test over sessions, so the test over pairs was taken as the main reading.

Partially reproduced15

  • Partially reproduced

    MS cooling typically peaked about 60 s after its onset and lasted about 10 to 12 minutes, about 50 trials.

    Over 37 sessions with a recorded temperature the minimum comes a median 121 s after the onset (IQR 89 to 138…

    STAR Methods, Electrophysiological Recordingscooling-time-course
    From the paper

    The cooling typically peaked after about 60 sec after the cooling onset ( suppl. fig. 1G ) and lasted for about 10–12 minutes, corresponding to approximately 50 trials

    Result

    Over 37 sessions with a recorded temperature the minimum comes a median 121 s after the onset (IQR 89 to 138 s; 119 to 122 s for onset thresholds of 0.5 to 2 C), against 60 s. The duration holds under reading (b), 12.16 minutes until the temperature is within 1 C of baseline; under reading (a) the temperature is below 32 C for 8.77 minutes. The median minimum is 21.2 C. The drop is fast and the temperature then stays near its minimum, so the time to the minimum overstates the time to the peak effect. 90% of each session's drop is reached a median 53 s after onset (IQR 44 to 63 s), and the onset-aligned mean trace is within 0.5 C of its minimum from 70 to 152 s. Without the five sessions whose baseline has artefacts above 38 C or whose onset is detected early, the values are 121.5 s and 12.22 minutes.

    Deviations from the paper’s method
    • The onset is taken from the temperature trace (1 C below the pre-cooling median), as the files have no time of dry-ice placement; the Methods do not define the onset.
  • Partially reproduced

    MS cooling induced a fast and reversible decrease of hippocampal theta frequency and power, lower during cooling than before and after it.

    Frequency is lower during cooling than before (44 of 45 sessions, P = 1.4e-12) and after (45 of 45, P =…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; Figure 2Ifig2i-theta-pre-cooling-post
    From the paper

    MS cooling induced fast and reversible change in the frequency and power of hippocampal theta oscillations

    Result

    Frequency is lower during cooling than before (44 of 45 sessions, P = 1.4e-12) and after (45 of 45, P = 5.7e-14). Power is lower than before at P = 0.048 (26 of 45) but not lower than after (19 of 45, P = 0.94); during cooling it is 0.972 of the session mean of the three states.

    Deviations from the paper’s method
    • State means over trials, from the dandiset's labels, with 'Cooling off' trials left out.
  • Partially reproduced

    During MS cooling LFP theta frequency decreased by about 12%.

    The decrease is 8.88% (a), 9.18% (b) and 9.23% (c), none within 12 +- 1.2%.

    Discussion, Theta phase organization of hippocampal cell assemblies, paragraph 5; Results, MS temperature effects on theta time/phase compression, paragraph 4disc-theta-frequency-12-percent
    From the paper

    During MS cooling, LFP theta frequency decreased by 12 %

    Result

    The decrease is 8.88% (a), 9.18% (b) and 9.23% (c), none within 12 +- 1.2%. The slowest cooling trial of a session is a mean 16.93% below pre. Per rat 4.76% (MS12) to 10.74% (MS21). The paper's within-field values (8.4 and 7.7 Hz) are reproduced in fig4b-fp-flfp-decrease.

    Deviations from the paper’s method
    • The paper does not say how the 12% is computed; three readings were tested.
  • Partially reproduced

    MS cooling increased choice errors about 3-fold, within each rat (P < 0.05 for all animals) and across all animals (P = 1e-6).

    Errors are 6.67% before and 15.23% during cooling (40 of 45 sessions higher, P = 3e-07), ratios 2.28 (a), 2.31…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6D and 6Efig6d-errors-increase
    From the paper

    Overall, the number of memory errors increased approximately 3-fold, assessed either within rats (P < 0.05 for all animals) or across all animals (P = 10 −6

    Reported statistics
    • within each rat: p < 0.05
    • across all animals: p = 10⁻⁶
    • boxplots over all sessions (Figure 6E, marked **): p < 10⁻⁷
    Result

    Errors are 6.67% before and 15.23% during cooling (40 of 45 sessions higher, P = 3e-07), ratios 2.28 (a), 2.31 (b) and 2.53 (c), all below 2.7. Per rat, P = 0.0078 (MS10), 0.039 (MS12), 0.027 (MS21) and 0.064 (MS22, 10 of 12 higher); MS13 has 5 sessions, all higher (P = 0.0625, the smallest possible). Counting 'Cooling off' trials as cooling gives a ratio of 1.98; TEMP sessions alone 1.96.

    Deviations from the paper’s method
    • States from the dandiset's trial labels; the code counts errors by time windows from the cooling onsets and offsets, which are not in the files.
    • 45 of 53 sessions; MS13 has 5 sessions here, too few for an exact signed-rank test to reach 0.05.
  • Partially reproduced

    The incidence of errors correlated negatively with MS temperature (R = -0.35, P < 0.01, all animals).

    Negative and stronger than reported, R = -0.838 (a, P = 5.9e-41), -0.789 (b) and -0.868 (c), none within -0.35…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6F and 6Jfig6f-errors-temperature
    From the paper

    The incidence of errors negatively and significantly correlated with temperature change (R = − 0.35; P < 0.01; all animals)

    Reported statistics
    • R = − 0.35, p < 0.01 (n = all animals)
    Result

    Negative and stronger than reported, R = -0.838 (a, P = 5.9e-41), -0.789 (b) and -0.868 (c), none within -0.35 +- 0.035. Over single trials pooled R = -0.127 (P = 5.5e-20); per rat -0.298 to -0.860. The paper's value may come from a different unit of analysis, which its text does not give.

    Deviations from the paper’s method
    • 37 sessions with a recorded temperature.
  • Partially reproduced

    The incidence of errors correlated negatively with theta frequency (R = -0.35, P < 0.01, all animals).

    R = -0.868 (a, P = 3.9e-47) and -0.733 (b), stronger than -0.35; per rat -0.341 to -0.829.

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6G and 6Jfig6g-errors-theta-frequency
    From the paper

    The incidence of errors negatively and significantly correlated with ... theta frequency (R = − 0.35; P < 0.01; all animals)

    Reported statistics
    • R = − 0.35, p < 0.01 (n = all animals)
    Result

    R = -0.868 (a, P = 3.9e-47) and -0.733 (b), stronger than -0.35; per rat -0.341 to -0.829.

  • Partially reproduced

    The incidence of errors correlated less with theta power; only 2 of 5 animals had a significant correlation.

    One rat counts (MS10, R = -0.425, P = 1.1e-09).

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6H and 6Jfig6h-errors-theta-power
    From the paper

    and less so with theta power (only 2 of 5 animals had significant R > − 0.3; P < 0.01)

    Result

    One rat counts (MS10, R = -0.425, P = 1.1e-09). MS21 is significant with R = -0.202 (P = 0.0063), and MS22 with the opposite sign (R = 0.325, P = 1.2e-05).

  • Partially reproduced

    Within-field and peak firing rates of place cells decreased moderately during MS cooling (11% and 12%; P < 1e-9 and P < 1e-11).

    Over 636 fields both rates fall (P = 0.0024 and 0.0013), by 3.7% and 5.3% as medians (a), 7.7% and 6.7% as…

    Results, Effects of MS cooling on single neuron properties, paragraph 2; Figure S2A, Bsuppl2-place-cell-rates-decrease
    From the paper

    Both within-field and peak firing rates of place cells decreased moderately during MS cooling ( Suppl. Fig. 2 ; 11% and 12%; P < 10 −9 and P < 10 −11 , respectively

    Reported statistics
    • within-field firing rate: p < 10⁻⁹
    • peak firing rate: p < 10⁻¹¹
    Result

    Over 636 fields both rates fall (P = 0.0024 and 0.0013), by 3.7% and 5.3% as medians (a), 7.7% and 6.7% as ratios of means (b); reading (c) is dominated by fields with near-zero pre rates (-111% and -70%). Fields with at least 50 spikes in each state give 10.8% and 9.9%. The decrease differs between rats (MS12 rises by 10.1%, MS13 falls by 27.8%).

    Deviations from the paper’s method
    • Place fields by the automatic criteria of the Methods for Figure 5; the paper defined the fields of this analysis by hand.
    • Putative pyramidal cells typed here from waveforms and rates; the files have no cell types.
  • Partially reproduced

    Firing rates of interneurons decreased during MS cooling by about 14%, about the same degree as place cells.

    127 putative interneurons, lower in 75 (P = 0.0017), by 6.5% (a) or 9.1% (b); thresholds of 0.35 and 0.5 ms…

    Discussion, Theta phase organization of hippocampal cell assemblies, paragraph 5; Results, Effects of MS cooling on single neuron properties, paragraph 2; Figure S2Cdisc-interneuron-rates-decrease
    From the paper

    within-field firing rates of place cells decreased by a similar proportion (12%; interneurons 14%).

    Result

    127 putative interneurons, lower in 75 (P = 0.0017), by 6.5% (a) or 9.1% (b); thresholds of 0.35 and 0.5 ms, and narrow units alone, give 9.4% to 9.9%.

    Deviations from the paper’s method
    • Putative interneurons typed here (trough-to-peak at most 0.425 ms, or above 10 Hz).
  • Partially reproduced

    fp and fLFP were correlated across place fields before, during and after cooling (R = 0.61, 0.59 and 0.36; P < 1e-6 each), with the range of fp larger than that of fLFP.

    All positive (P = 1.5e-05, 6.7e-19 and 0.0029) and weaker than 0.61, 0.59 and 0.36; within rats R ranges from…

    Figure 4C; Results, Effects of MS cooling on single neuron properties, paragraph 2fig4c-fp-flfp-correlation
    From the paper

    Correlation between LFP theta frequency ( f LFP ) and place cell oscillation frequency ( f p ; R pre = 0.61; R cooling = 0.59; Rpost = 036; P < 10 −6 each)

    Reported statistics
    • each of before, during and after cooling: R pre = 0.61; R cooling = 0.59; Rpost = 036, p < 10⁻⁶
    Result

    All positive (P = 1.5e-05, 6.7e-19 and 0.0029) and weaker than 0.61, 0.59 and 0.36; within rats R ranges from -0.05 to 0.64.

  • Partially reproduced

    fLFP and fp measured within place fields decreased linearly with MS temperature (fLFP R = 0.66, slope 0.071 Hz per C; fp R = 0.38, slope 0.09 Hz per C).

    Over 52474 windows from 563 fields, fLFP R = 0.678 and slope 0.0716 Hz per C, fp slope 0.0859, within…

    Results, Effects of MS cooling on single neuron properties, paragraph 1; Figure 4Afig4a-frequency-temperature-slopes
    From the paper

    The theta oscillation frequency of pyramidal neurons decreased linearly and paralleled the downward frequency shift of LFP theta oscillation ( Fig. 4a ; f LFP : R = 0.66, Slope = 0.071. f p : R = 0.38, slope = 0.09).

    Result

    Over 52474 windows from 563 fields, fLFP R = 0.678 and slope 0.0716 Hz per C, fp slope 0.0859, within tolerance; fp R = 0.338, just below 0.342. The windows overlap (stepped by one trial), so the P values over windows overstate the evidence; the paper's code does the same.

    Deviations from the paper’s method
    • Windows of 20 trials stepped by one trial, as calc_trial_averages.m; the paper's figure does not say which windows it plots.
  • Partially reproduced

    Place field size and fp were negatively correlated before, during and after cooling (R = -0.49, -0.40, -0.40; P < 1e-9), with similar slopes and a slightly lower intercept during cooling.

    All negative with P below 3e-09, weaker than -0.49 and -0.40.

    Figure 3D; Results, Effect of MS cooling on place field features, paragraph 1fig3d-size-fp-negative
    From the paper

    Place field size continues to be inversely correlated with f p after MS cooling (R pre = − 0.49; R cooling = − 0.40; R post = − 0.40. P < 10 −9 all conditions).

    Reported statistics
    • each of before, during and after cooling: R pre = − 0.49; R cooling = − 0.40; R post = − 0.40, p < 10⁻⁹
    Result

    All negative with P below 3e-09, weaker than -0.49 and -0.40.

  • Partially reproduced

    Measured place field size correlated with the size predicted by S = v / (fp - fLFP) before (R = 0.55), during (R = 0.54) and after (R = 0.11) cooling.

    Pre and cooling positive (P = 4.7e-06 and 4.9e-11) and weaker than 0.55 and 0.54; post 0.325 against 0.11.

    Results, Effect of MS cooling on place field features, paragraph 2; Figure 3Efig3e-model-field-size
    From the paper

    We found a reliable and similar relationships between measured place field sizes and model-predicted sizes for trials before (R = 0.55), during (R = 0.54) and after (R = 0.11) MS cooling

    Result

    Pre and cooling positive (P = 4.7e-06 and 4.9e-11) and weaker than 0.55 and 0.54; post 0.325 against 0.11. Predicted sizes (median 47 to 48 cm) are smaller than measured (65 cm).

  • Partially reproduced

    The phase precession slope decreased slightly but significantly during MS cooling (P < 0.007 and P < 0.0003).

    Under reading (a), the slope magnitude during cooling does not differ from pre (median change 0, P = 0.83) and…

    Results, Effects of MS cooling on single neuron properties, paragraph 2; Figure 4Dfig4d-precession-slope-decrease
    From the paper

    decreased slightly, but nevertheless significantly, during MS cooling ( Fig. 4d ).

    Reported statistics
    • comparison marked ** in Figure 4D: p < 0.007
    • comparison marked *** in Figure 4D: p < 3 × 10⁻⁴
    Result

    Under reading (a), the slope magnitude during cooling does not differ from pre (median change 0, P = 0.83) and is smaller than post (P = 0.022); under (b) neither comparison differs (P = 0.32 and 0.15). 87.5% of fields have a negative slope before cooling.

    Deviations from the paper’s method
    • The direction of 'decreased' is not stated; two readings were tested.
    • Slopes by a grid search of circular-linear regression up to two cycles per field.
  • Partially reproduced

    The theta-repeated cross-correlograms of place cell pairs had a period of about 85 ms before cooling, shorter than the LFP theta period (about 110 ms), and the period lengthened during MS cooling in each session (P = 0.002), while the period of the phase cross-correlograms was unaffected (P = 0.32).

    Over 9 sessions the period lengthens from 109.2 to 114.0 ms (8 of 9, P = 0.0195) and the phase period does not…

    Figure 5D and 5F; Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 2fig5d-ccg-period
    From the paper

    Duration of the theta-repeated spike cross-correlograms (as in d ), calculated for each session, significantly increased during MS cooling ... whereas the spike phase-lag correlations remained unaffected (n.s., P = 0.32).

    Reported statistics
    • period of the time cross-correlograms, cooling against control (pre and post): two-sided signed rank test, p = 0.002
    • period of the phase cross-correlograms, cooling against control: p = 0.32
    Result

    Over 9 sessions the period lengthens from 109.2 to 114.0 ms (8 of 9, P = 0.0195) and the phase period does not change (1.740 and 1.760 pi rad, P = 0.59); the control period is not 85 +- 8.5 ms. The criterion's estimator takes the largest neighbouring peak 60 to 200 ms from the main peak, and in 47.7% of pre pairs that peak is more than 1.25 times as far as the nearest one, so it often picks the second neighbour and the 109.2 ms is biased upward. With the nearest neighbouring peak (a variant) the control period is 91.0 ms, within tolerance, and it lengthens to 95.5 ms (7 of 9, P = 0.031); pairs with |Ltr| below 10 cm give 91.0 ms. Under that variant the phase period, also from the nearest peak, does not change (1.285 pi rad in both, P = 0.367), so all three parts of the criterion hold; but that estimator is biased downward, as 211 of 3499 pre pairs give 60 to 70 ms, at the floor of the search window and below any plausible theta period, so its 91.0 ms is not a clean test of 85 ms either. The outcome follows the criterion's estimator. Both control periods are shorter than the LFP theta period (115.7 ms).

    Deviations from the paper’s method
    • The period is measured per pair and summarised per session; the paper reads it from the sum over pairs. The criterion was changed to this before the analysis across sessions, after a pilot session showed that the summed correlogram's spectrum follows its envelope; the summed correlogram is shown as a variant (99 to 200 ms).
    • 9 sessions in 4 rats, against 18 in 5.
    • The criterion's period estimator often takes the second neighbouring peak; the nearest-peak estimator is shown as a variant.

Not reproduced10

  • Not reproduced

    Theta power also decreased with MS temperature, less tightly than frequency (R = 0.54, P = 1.2e-16).

    Theta power does not follow temperature, R = -0.056 (P = 0.44) over TEMP sessions and R = 0.123 (P = 0.085)…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; Figure 2Hfig2h-theta-power-temperature
    From the paper

    this relationship was more consistent across animals than the effect on theta power (R = 0.54; P = 1.2 × 10 −16 ; Fig. 2g , h )

    Reported statistics
    • R = 0.54, p = 1.2 × 10⁻¹⁶ (n = 53 sessions in 5 rats)
    Result

    Theta power does not follow temperature, R = -0.056 (P = 0.44) over TEMP sessions and R = 0.123 (P = 0.085) with the MS10 curves; over single trials pooled R = 0.107. Power is the spectrogram magnitude of the band-passed LFP as in calcInstantaneousTheta.m, minus each session's mean, at frames above 30 cm/s, and the 10 cm/s variant gives R = 0.135. Per rat the power R ranges from -0.346 to 0.376.

    Deviations from the paper’s method
    • The theta electrode is the one flagged theta_reference in the files, which may differ from the paper's; power depends on the electrode more than frequency does. The LFP column read is that row in every session (checked through the LFP electrodes region).
    • Power is taken from the spectrogram of the 4 to 10 Hz band-passed LFP, as in the paper's code (calcInstantaneousTheta.m); the band-pass weights frequencies within the band unequally.
  • Not reproduced

    The incidence of errors did not correlate with the running speed of the rat (R about 0.1, P > 0.05 for all animals).

    Three of five rats have P < 0.05, MS13 (R = -0.493, P = 8e-11), MS21 (R = 0.216, P = 0.0034) and MS22 (R =…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6I and 6Jfig6i-errors-not-speed
    From the paper

    and not with the running speed of the rat (R ~ 0.1; P > 0.05 for all animals

    Reported statistics
    • R ~ 0.1, p > 0.05 (n = all animals)
    Result

    Three of five rats have P < 0.05, MS13 (R = -0.493, P = 8e-11), MS21 (R = 0.216, P = 0.0034) and MS22 (R = 0.247, P = 0.001); MS10 and MS12 do not (P = 0.32 and 0.49). Over all sessions together R = 0.093 (P = 0.19). The correlations are over about 150 to 190 aligned positions, so small R values reach significance.

  • Not reproduced

    In the sessions of Figure 5, mean running speed was 87.3 +- 8.0 in control trials (pre and post combined) and 86.2 +- 9.9 during MS cooling.

    Over 15 sessions, reading (a) gives control 78.9 and cooling 74.9 cm/s, both outside; reading (b) gives…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 2verifier disagreed at firstfig5-speed-control-cooling
    From the paper

    we combined trials before and after cooling into a single control group (mean running speed = 87.3±8.0). During MS cooling (mean running speed = 86.2±9.9)

    Result

    Over 15 sessions, reading (a) gives control 78.9 and cooling 74.9 cm/s, both outside; reading (b) gives control 79.6, within 87.3 +- 8.0, and cooling 76.0, 0.3 cm/s below 86.2 +- 9.9. The criterion needs both values within tolerance under one reading, and neither reading gives both. Speed is lower during cooling than in control (P = 0.035 to 0.041).

    Deviations from the paper’s method
    • 15 of the code's 18 Figure 5 sessions; the paper does not define its speed measure.
  • Not reproduced

    The waveforms of hippocampal action potentials were not affected by MS cooling.

    Over 646 units, trough-to-peak differs (P = 4.9e-10, median change 0 as most units do not move by a whole 0.05…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 3; Figure S1Gsuppl1g-waveforms-unchanged
    From the paper

    Finally, the waveforms of action potentials in the hippocampus ... were not affected by MS cooling ( Suppl. Fig. 1g ).

    Result

    Over 646 units, trough-to-peak differs (P = 4.9e-10, median change 0 as most units do not move by a whole 0.05 ms sample) and amplitude rises by a median 0.8% (P = 0.00057). The windows start 7.1 to 31.8 minutes apart (5.1 to 29.8 minutes from the end of the pre window), so drift cannot be separated from cooling; for interneurons alone neither differs (P = 0.066 and 0.2). Fewer spikes are averaged in the cooling window (median 200 against 247.5), but in the 208 units whose two means both use the 300-spike cap the changes remain (amplitude 0.7%, P = 0.032; trough-to-peak P = 2.2e-05), so the spike count does not explain them. The effect is small, and the outcome follows the paper's test as written; it does not show that cooling changes the waveforms.

    Deviations from the paper’s method
    • Waveforms from 120 s windows of the wide-band data at 20 kHz, high-passed at 300 Hz, on the channel of largest amplitude; the paper's measure is in its supplement, which could not be read.
  • Not reproduced

    During MS cooling fp and fLFP decreased in parallel, so the difference fp - fLFP remained constant.

    fp - fLFP falls from 2.009 to 1.806 Hz (median change -0.128 Hz, P = 0.000132, 361 fields) and stays at 1.790…

    Discussion, Theta phase organization of hippocampal cell assemblies, paragraph 3; Results, Effects of MS cooling on single neuron properties, paragraph 2fig4ac-fp-flfp-difference-preserved
    From the paper

    However, during MS cooling f p and f LFP decreased proportionally (i.e., f p – f LFP difference remained constant)

    Result

    fp - fLFP falls from 2.009 to 1.806 Hz (median change -0.128 Hz, P = 0.000132, 361 fields) and stays at 1.790 Hz after cooling; the ratio fp/fLFP is preserved (1.237 and 1.232, P = 0.84). By rat the mean change is -1.03 Hz (MS12), 0.01 (MS13), -0.19 (MS21) and 0.10 (MS22).

    Deviations from the paper’s method
    • The paper names no test; its default paired test was used.
  • Not reproduced

    The information content of place cell spikes was not altered by MS cooling (P > 0.26).

    Over 374 place cells information is lower during cooling than before (median change -0.029 against a median of…

    Results, Effect of MS cooling on place field features, paragraph 2; Figure 3Ffig3f-information-unchanged
    From the paper

    Information content of place cell spikes was also left unaltered by MS cooling (P > 0.26; Fig. 3f ).

    Reported statistics
    • p > 0.26
    Result

    Over 374 place cells information is lower during cooling than before (median change -0.029 against a median of 1.253 bits/spike, P = 0.014) and lower after than before (P = 0.0064); cooling and post do not differ (P = 0.31). The changes are small. Bits per spike rise when fewer spikes are used, and the pre state has the fewest trials, but with each state's spikes subsampled to the same count (360 cells) pre against cooling gives P = 0.0073 and pre against post P = 0.0092, so the decrease does not come from the spike counts.

    Deviations from the paper’s method
    • The paper names its comparisons but not its test; its default paired test was used.
  • Not reproduced

    Distance-time compression of place cell pairs (0.54 cm/ms before cooling) decreased during MS cooling (P = 0.02), while distance-phase compression was unchanged (P = 0.92).

    Pooled pre compression 0.273 cm/ms against 0.54.

    Figure 5C and 5G; Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 2fig5cg-compression
    From the paper

    Compression index, c (cm/ms; i.e., the slope in c ), significantly decreased during MS cooling (* P = 0.02) but the distance/phase lag compression (cm/radian) remained unaffected (P = 0.92).

    Reported statistics
    • distance-time compression, cooling against control: p = 0.02
    • distance-phase compression, cooling against control: p = 0.92
    Result

    Pooled pre compression 0.273 cm/ms against 0.54. Per session it is lower during cooling in 8 of 9 sessions without significance (0.298 against 0.191, P = 0.0547); phase compression does not change (P = 0.426). Lag and distance correlate weakly (R = 0.195), so the slope depends on the fit (inverse regression over pooled pre pairs 7.175 cm/ms). The 70 ms window can hold more than one candidate peak; in 10.5% of pre pairs the lag changes when the window is narrowed to half the theta period, which gives 0.156 cm/ms. The compression magnitude cannot be judged from this method. The direction of the change agrees with the paper under the criterion's fit; the inverse slope goes the other way (control 9.085, cooling 10.420 cm/ms, lower in 1 of 9).

    Deviations from the paper’s method
    • Lags from each pair's correlogram peak and compression from a regression, where the paper fits a surface to the density of all pairs; pairs without a peak within 70 ms are dropped.
  • Not reproduced

    Theta phase lags between place cell pairs were not affected by MS cooling (P > 0.24 between all conditions).

    Phase lags are slightly larger during cooling than before (1.367 against 1.304 rad, mean difference 0.051 rad…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 3; Figure 5Ifig5i-phase-lags-unchanged
    From the paper

    In contrast, phase lags between spikes of place cell pairs were not affected by MS cooling ( Fig. 5i ; P > 0.24 between all conditions).

    Reported statistics
    • Wilcoxon signed rank test, p > 0.24
    Result

    Phase lags are slightly larger during cooling than before (1.367 against 1.304 rad, mean difference 0.051 rad, P = 0.0015) and after (P = 0.0043); pre and post do not differ (P = 0.51). Per session medians, cooling against pre P = 0.062. The +-pi window spans about 1.15 periods of the phase correlogram (1.74 pi). With the lag picked within +-pi/2 (a variant), 43.3% of pre pairs get another lag or none, and cooling is still above pre (mean difference 0.025 rad, P = 0.0196) but not above post (P = 0.162); pre and post do not differ (P = 0.178). Part of the increase may come from how the lag is picked.

  • Not reproduced

    The fraction of place cells active in a given theta cycle was not significantly affected by MS cooling (P = 0.2).

    The fraction active is higher during cooling (0.2405 against 0.226, rank-sum P = 1.5e-22 over 9037 and 10152…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 4; Figure 5Jfig5j-fraction-active-unchanged
    From the paper

    we found that the fraction of place cells active in a given theta cycle was not significantly affected by MS cooling ( Fig. 5j ; P = 0.2).

    Reported statistics
    • as given in the Results: p = 0.2
    • pre against cooling (legend): p = 0.28
    • post against cooling (legend): p = 0.006
    • pre against post (legend): p = 5 × 10⁻⁴
    Result

    The fraction active is higher during cooling (0.2405 against 0.226, rank-sum P = 1.5e-22 over 9037 and 10152 cycles). Per session the cooling mean is lower than pre in 5 of 9 sessions (P = 0.734); cooling against post gives P = 0.074 and pre against post P = 0.004. Session means range from 0.159 to 0.315 and sessions contribute different numbers of cycles in each state, so the pooled test reflects the make-up of the pool as much as an effect. Cycles are longer during cooling (131.1 ms against 117.8 and 117.2 ms).

    Deviations from the paper’s method
    • The paper does not name its test; the default rank-sum test over cycles was fixed before the analysis.
  • Not reproduced

    The number of spikes emitted by all neurons per theta cycle was preserved during MS cooling (P > 0.058 between all conditions).

    Pre and cooling do not differ (45.68 and 44.98 spikes, P = 0.0758), but post (51.68) differs from both (P…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 4; Figure 5Kfig5k-spikes-per-cycle-unchanged
    From the paper

    The number of spikes emitted by all neurons per theta cycle was also preserved after MS cooling ( Fig. 5k )

    Reported statistics
    • p > 0.058
    Result

    Pre and cooling do not differ (45.68 and 44.98 spikes, P = 0.0758), but post (51.68) differs from both (P below 1e-50). Per session, cooling differs from neither pre (P = 0.57) nor post (P = 0.129), and post differs from pre (P = 0.02). Session means range from 17.66 to 91.37 spikes, so the pooled tests depend on how many cycles each session contributes.

    Deviations from the paper’s method
    • Spikes of all good and good2 units; the paper's 'all neurons' may include other units.

Not tested in a notebook 1

1 data missing from the dataset

Blocked1

  • Blocked

    In a control experiment, hippocampal temperature fell by less than 1.5 C at the largest MS temperature decrease (16 C), and later than the MS (MS maximum at about 45 s, time constant 11 s; hippocampus peak at 115 s, time constants 48 s right and 72 s left).

    The control experiment that measured temperature in the MS and both hippocampi is not in the dandiset, whose…

    Data missing from the datasetResults, MS cooling decreases hippocampal theta frequency and power, paragraph 3; Figure S1H to Ksuppl1-hippocampal-temperature
    From the paper

    found < 1.5° C decrease in the hippocampus at the time of the largest MS temperature decrease (16° C) ... (maximum effect at approximately 45 s; time constant: 11 s), the mild temperature decrease in the hippocampus was considerably delayed (peak at 115 s; time constant 48 s for the right hippocampus, and 72 s for the left)

    Result

    The control experiment that measured temperature in the MS and both hippocampi is not in the dandiset, whose files hold only the MS temperature of the 50 behavioural sessions. The data check lists every series in all 100 files, and the only temperature series is processing/behavior/Temperature. The paper's data statement points to the lab website and CRCNS; no other DANDI deposit of these recordings was found.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Paper inconsistentThe legend of Figure 5H gives P = 8.0e-5 by a sign rank test with N = 10 sessions; an exact signed-rank test over 10 sessions cannot give a P below 0.002, so the test must be over pairs or the N refers to something else.#
  • Paper inconsistentThe Discussion gives a 12% decrease of LFP theta frequency during cooling, while the Results give within-field LFP theta of 8.4 Hz before and 7.7 Hz during cooling, a decrease of about 8%, which this attempt reproduces (9% over trials).#

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Cooling of the medial septum and hippocampal theta coordination (Petersen and Buzsaki 2020)

Tests the findings of Petersen and Buzsaki (2020) on dandiset 000059, which holds 51 sessions of 5 rats running a figure-8 maze while the medial septum was cooled, with CA1 LFP, curated units, head tracking and the septal temperature. It tests the effects of cooling on theta frequency and power, choice errors, running speed, place cell rates, oscillation frequency, field features, phase precession and the theta time and phase lags of place cell pairs. The hippocampal temperature of the paper's control experiment is not in the dandiset. All files

Environment: Python 3.13, 20 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-10-16
    Agreed with 37 of 38 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The executed notebook of the first run with the conclusion cells and the summary removed, the helper module and the claims file, with the PMC author manuscript of the paper. The verifier checked the blocked claim against the archive's file list and metadata and tested the helper functions on synthetic inputs. Report in transcripts/000059/verifier-1-report.md.
    • fig5-speed-control-cooling: the verifier’s outcome was “Not reproduced”. In cell 58 reading (a) gives 78.9 and 74.9 cm/s, both outside. Reading (b) gives control 79.6 (inside) and cooling 76.0 (just below 76.3).
  • Round 2
    2026-10-16
    Agreed with 38 of 38 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The full executed notebook of the revised run, with the conclusions and the summary, the helper module, the claims file and this record. The verifier did not re-read the paper text this round. Report in transcripts/000059/verifier-2-report.md. It also found that the Summary and the first finding say the MS10 and control temperatures run from exactly 17 to 37 C, which is exact in nine of the ten (MS10-170313 reaches 16.9777 C, cell 11); both now say so. Everything under C of its round-1 report is resolved.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • 45 of the paper's 53 sessions.session-structure
  • The onset is taken from the temperature trace (1 C below the pre-cooling median), as the files have no time of dry-ice placement; the Methods do not define the onset.cooling-time-course
  • 37 sessions with a recorded temperature, where the paper used 53; the MS10 temperature in the dandiset is not a recording.fig2g-theta-freq-temperature
  • The theta electrode is the one flagged theta_reference in the files; the code's channel numbers could not be mapped to the files' electrodes.fig2g-theta-freq-temperature
  • The theta electrode is the one flagged theta_reference in the files, which may differ from the paper's; power depends on the electrode more than frequency does. The LFP column read is that row in every session (checked through the LFP electrodes region).fig2h-theta-power-temperature
  • Power is taken from the spectrogram of the 4 to 10 Hz band-passed LFP, as in the paper's code (calcInstantaneousTheta.m); the band-pass weights frequencies within the band unequally.fig2h-theta-power-temperature
  • Four rats; MS10 has no recorded temperature.fig2j-frequency-consistent-across-animals
  • State means over trials, from the dandiset's labels, with 'Cooling off' trials left out.fig2i-theta-pre-cooling-post
  • The paper does not say how the 12% is computed; three readings were tested.disc-theta-frequency-12-percent
  • States from the dandiset's trial labels; the code counts errors by time windows from the cooling onsets and offsets, which are not in the files.fig6d-errors-increase
  • 45 of 53 sessions; MS13 has 5 sessions here, too few for an exact signed-rank test to reach 0.05.fig6d-errors-increase
  • The figure's 'ns' was read as pre against post.fig6e-errors-recover
  • 37 sessions with a recorded temperature.fig6f-errors-temperature
  • 15 of the code's 18 Figure 5 sessions; the paper does not define its speed measure.fig5-speed-control-cooling
  • Place fields by the automatic criteria of the Methods for Figure 5; the paper defined the fields of this analysis by hand.suppl2-place-cell-rates-decrease
  • Putative pyramidal cells typed here from waveforms and rates; the files have no cell types.suppl2-place-cell-rates-decrease
  • Putative interneurons typed here (trough-to-peak at most 0.425 ms, or above 10 Hz).disc-interneuron-rates-decrease
  • Putative interneurons typed here; the paper's fast-spiking interneurons come from CellExplorer.suppl2d-interneuron-oscillation-slows
  • Waveforms from 120 s windows of the wide-band data at 20 kHz, high-passed at 300 Hz, on the channel of largest amplitude; the paper's measure is in its supplement, which could not be read.suppl1g-waveforms-unchanged
  • Fields by the automatic criteria of the Methods, from 11 sessions in 4 rats.fig4b-fp-flfp-decrease
  • The paper names no test; its default paired test was used.fig4ac-fp-flfp-difference-preserved
  • Windows of 20 trials stepped by one trial, as calc_trial_averages.m; the paper's figure does not say which windows it plots.fig4a-frequency-temperature-slopes
  • Field size from rate maps of each state (bins above 10% of the peak); the paper does not define it.fig3c-field-size-correlated
  • The paper names its comparisons but not its test; its default paired test was used.fig3f-information-unchanged
  • The decorrelation scale is computed within maze segments at 5 cm bins; 11 sessions.fig3hi-population-vector-unchanged
  • The direction of 'decreased' is not stated; two readings were tested.fig4d-precession-slope-decrease
  • Slopes by a grid search of circular-linear regression up to two cycles per field.fig4d-precession-slope-decrease
  • Speed bins of 20 cm/s; the paper's bins are not stated.fig4gh-fp-speed
  • The period is measured per pair and summarised per session; the paper reads it from the sum over pairs. The criterion was changed to this before the analysis across sessions, after a pilot session showed that the summed correlogram's spectrum follows its envelope; the summed correlogram is shown as a variant (99 to 200 ms).fig5d-ccg-period
  • 9 sessions in 4 rats, against 18 in 5.fig5d-ccg-period
  • The criterion's period estimator often takes the second neighbouring peak; the nearest-peak estimator is shown as a variant.fig5d-ccg-period
  • Lags from each pair's correlogram peak and compression from a regression, where the paper fits a surface to the density of all pairs; pairs without a peak within 70 ms are dropped.fig5cg-compression
  • The legend's n = 10 sessions cannot give P = 8e-5 with a signed-rank test over sessions, so the test over pairs was taken as the main reading.fig5h-time-lags-increase
  • The paper does not name its test; the default rank-sum test over cycles was fixed before the analysis.fig5j-fraction-active-unchanged
  • Spikes of all good and good2 units; the paper's 'all neurons' may include other units.fig5k-spikes-per-cycle-unchanged

Provenance

Attempt record
petersen-2020-01
Paper
Cooling of Medial Septum Reveals Theta Phase Lag Coordination of Hippocampal Cell Assemblies
Date
2026-10-16
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:000059 (on DANDI)
Version
0.250624.0444 (doi:10.48324/dandi.000059/0.250624.0444)
Run on
GitHub Actions
Harness
Claude Code (GitHub Actions)
Model
claude-opus-5-5
Protocol
pilot-7

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Other data and code used 1

What the attempt used that is not in the dataset: other data, and the paper’s code. Each is as the attempt’s record describes it.

  • petersenpeter/Code_Petersen_Buzsaki_Neuron_2020 GitHub

    The paper's MATLAB analysis code, read and not run. It supplies the lists of sessions of the behavioural analysis and of Figure 5 (BatchProcessing.m), the recording list that marks which sessions have a temperature channel and which are controls without cooling (MedialSeptum_Recordings.m), and the parameters of the theta measures, trial averages and onset-aligned series (calcInstantaneousTheta.m, BatchProcessing.m, calc_trial_averages.m). It brings in no measurements.

    Source as recorded: https://github.com/petersenpeter/Code_Petersen_Buzsaki_Neuron_2020 at commit aec2f7e4ffac79abaa71bb3515c1da7a6d383990