Papers / Petersen et al. 2020

Petersen et al. 2020 · Neuron

Cooling of Medial Septum Reveals Theta Phase Lag Coordination of Hippocampal Cell Assemblies

Peter Petersen, György Buzsáki

Outcomes of 46 claims

  • 17 reproduced
  • 19 partially reproduced
  • 8 not reproduced
  • 2 blocked

Summary: Most of the paper's main findings hold in this data: cooling the medial septum slows hippocampal theta, raises choice errors (about twofold, where the paper reports threefold) and slows place cell oscillations along with LFP theta. Theta time lags between place cell pairs lengthen, and phase lags stay unchanged only under one reading of the lag. The preserved gap between place cell and LFP theta frequency, and the stable place field size and information, did not hold; the paper drew its fields by hand and they are not shared. Distance-time compression could not be tested, as the paper's surface fit fails on this data and its procedure is not described.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Attempts 2

1 current, 1 replaced

Every attempt on the paper, each with the datasets it used and their versions. An attempt on a dataset replaces the one before it on that dataset; the paper’s page shows the current ones.

  1. Attempt 012026-10-16replaced
    DANDI:000059 version 0.250624.0444
    38 claims · 11 findings about the data · protocol pilot-7
  2. Attempt 02Viewing2026-11-15current
    DANDI:000059 version 0.261115.0311
    46 claims · 10 findings about the data · protocol pilot-15

Claims

Reproducing Petersen and Buzsaki (2020) from dandiset 000059 46 Open in Colab

Reproduced17

  • Reproduced

    Theta power also decreased with MS temperature, less tightly than frequency (R = 0.54, P = 1.2e-16).

    Reading (a) with the mean squared Hilbert amplitude: R = 0.495, P = 8.9e-9 over 120 aligned trials, within…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; Figure 2Hwas not reproduced in attempt 01fig2h-theta-power-temperature
    From the paper

    this relationship was more consistent across animals than the effect on theta power (R = 0.54; P = 1.2 × 10 −16 ; Fig. 2g , h )

    Reported statistics
    • R = 0.54, p = 1.2 × 10⁻¹⁶ (n = 53 sessions in 5 rats)
    Result

    Reading (a) with the mean squared Hilbert amplitude: R = 0.495, P = 8.9e-9 over 120 aligned trials, within 0.486 to 0.594 and below the frequency R (0.978) of the same reading. Power normalised by the session's pre mean gives 0.489. The spectral peak power gives R = 0.761 (0.811 normalised); pooled trials give R of 0.05 to 0.28. The criterion asks for one reading; 3 of the 18 measure and reading combinations meet it (Hilbert power, raw, running or normalised, over aligned trials), and spectral power and the bin and pooled readings do not, so the outcome depends on the power measure and the reading.

    Attempt 01: not reproduced. A difference in the power measure, which the rewritten claims file leaves open with readings. The earlier attempt took the code's spectrogram magnitude at frames above 30 cm/s minus each session's mean (R = -0.056); the blind attempt takes the mean squared Hilbert amplitude over the trial (R = 0.495), and 3 of its 18 measure and reading combinations meet the criterion.

    Deviations from the paper’s method
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
  • Reproduced

    The relationship of theta frequency with MS temperature was more consistent across animals than that of theta power.

    Per rat over aligned trials (reading a, Hilbert): frequency R = 0.559 (MS12), 0.857 (MS13), 0.958 (MS21)…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; Figure 2Jfig2j-frequency-consistent-across-animals
    From the paper

    Theta frequency decreased linearly with MS temperature ... and this relationship was more consistent across animals than the effect on theta power

    Result

    Per rat over aligned trials (reading a, Hilbert): frequency R = 0.559 (MS12), 0.857 (MS13), 0.958 (MS21), 0.944 (MS22), all P below 4e-11; raw power R = -0.030, -0.139, 0.630, -0.251 and normalised power 0.129, 0.185, 0.681, -0.209. Range of R 0.399 for frequency against 0.881 and 0.890 for power; SD 0.186 against 0.396 and 0.367; rats with P < 0.05, 4 for frequency against 2 and 3 for power. MS10 has no measured temperature, so the claim is tested on 4 of the 5 rats; the outcome holds for those 4.

    Deviations from the paper’s method
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • MS10, one of the paper's five rats, cannot be tested: its files hold only the modelled temperature.
  • Reproduced

    MS cooling induced a fast and reversible decrease of hippocampal theta frequency and power, lower during cooling than before and after it.

    Spectral theta reading, lab states, 50 sessions: frequency 8.40, 7.59 and 8.45 Hz (cooling against pre P =…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; Figure 2Iwas partially reproduced in attempt 01fig2i-theta-pre-cooling-post
    From the paper

    MS cooling induced fast and reversible change in the frequency and power of hippocampal theta oscillations

    Result

    Spectral theta reading, lab states, 50 sessions: frequency 8.40, 7.59 and 8.45 Hz (cooling against pre P = 8.1e-11, against post P = 3.6e-15), power cooling/pre 0.82 and cooling/post 0.87 (P = 2.5e-7 and 3.2e-6); the same holds under the 12 and 10 min states (49 sessions). With the Hilbert measures frequency falls (P below 1e-9) and power falls against pre (P = 0.004) but not against post (P = 0.42, ratio 1.05). Without MS13-171130, whose tagged theta channel is marked bad, the spectral reading gives the same (49 sessions, all four P below 1e-5).

    Attempt 01: partially reproduced. A difference in the power measure. Both find frequency lower during cooling than before and after; the earlier attempt found power not lower than post (P = 0.94) with the code's spectrogram measure, and the blind attempt finds it lower with the spectral peak power (P = 3.2e-6) but not with the Hilbert power (P = 0.42).

    Deviations from the paper’s method
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
    • MS12-170715 has no LFP and is left out.
    • The lab's theta channel of MS13-171130 is marked bad in the electrodes table; it is used, and the result without that session is shown.
  • Reproduced

    During MS cooling LFP theta frequency decreased by about 12%.

    Reading (c), largest decrease of the aligned mean relative to its pre mean: 11.1% (Hilbert), 12.9% (spectral)…

    Discussion, Theta phase organization of hippocampal cell assemblies, paragraph 5; Results, MS temperature effects on theta time/phase compression, paragraph 4was partially reproduced in attempt 01disc-theta-frequency-12-percent
    From the paper

    During MS cooling, LFP theta frequency decreased by 12 %

    Result

    Reading (c), largest decrease of the aligned mean relative to its pre mean: 11.1% (Hilbert), 12.9% (spectral), 10.9% (Hilbert, running samples); 3 of 21 readings fall within 10.8 to 13.2%. Readings (a) and (b), the mean per-session decrease, give 6.6 to 9.9% under the three state readings. The criterion asks for one reading; only reading (c), the minimum of the aligned series, is in tolerance, and a minimum of a noisy series favours larger decreases.

    Attempt 01: partially reproduced. A change in the claims file. Its reading (c) is now the largest decrease of the aligned mean series, which gives 11.1% in the blind attempt; under the mean per-session readings both attempts find about 9% (8.88 to 9.23% and 6.6 to 9.9%).

    Deviations from the paper’s method
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
  • Reproduced

    The error rate after cooling did not differ from the error rate before it.

    Post against pre error rates: 6.8% against 7.3%, median difference -0.42 points, signed-rank P = 0.55 over 51…

    Figure 6E (marked ns)fig6e-errors-recover
    From the paper

    Choice errors shown as boxplots constructed from all sessions. ** P < 10 −7 ns = nonsignificant.

    Result

    Post against pre error rates: 6.8% against 7.3%, median difference -0.42 points, signed-rank P = 0.55 over 51 sessions (P = 0.80 and 0.97 under the 12 and 10 min readings).

    Deviations from the paper’s method
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
  • Reproduced

    The worst memory performance occurred between trials 4 and 8 after the onset of cooling, when MS temperature reached its minimum, together with the largest decreases of theta frequency and power.

    Unsmoothed: error incidence peaks at aligned trial 8 (0.31 against 0.07 pre); mean MS temperature minimum at…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6Cfig6c-worst-trials-4-to-8
    From the paper

    The worst memory performance occurred between trials 4 and 8 after MS cooling, when the MS temperature reached its minimum, accompanied by the largest decreases of theta frequency and power

    Result

    Unsmoothed: error incidence peaks at aligned trial 8 (0.31 against 0.07 pre); mean MS temperature minimum at trial 7 (23.6 C), theta frequency at trial 8 (Hilbert; trial 6 spectral), normalised theta power at trial 8. With a 5-trial mean the error peak is at trial 6. Errors from 51 sessions, theta from 50, temperature from 31. Without MS13-171130 (theta channel marked bad) the theta minima fall on the same trials.

    Deviations from the paper’s method
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • Trials after a second cooling onset are left out of the aligned series.
    • The lab's theta channel of MS13-171130 is marked bad in the electrodes table; it is used, and the result without that session is shown.
  • Reproduced

    The incidence of errors correlated less with theta power; only 2 of 5 animals had a significant correlation.

    Per rat over aligned trials with the per-session normalised Hilbert power: MS13 R = -0.351 (P = 8.6e-5) and…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6H and 6Jwas partially reproduced in attempt 01fig6h-errors-theta-power
    From the paper

    and less so with theta power (only 2 of 5 animals had significant R > − 0.3; P < 0.01)

    Result

    Per rat over aligned trials with the per-session normalised Hilbert power: MS13 R = -0.351 (P = 8.6e-5) and MS21 R = -0.483 (P = 2.4e-8) count, 2 of 5; MS10 -0.180 (P = 0.049), MS12 0.047, MS22 0.125. Raw Hilbert power gives 3 rats (MS10, MS13, MS21) and normalised spectral power 1 (MS21); no rat has R above -0.3 with P < 0.01. The power measure is not fixed by the paper; the outcome holds under the first. Without MS13-171130 (theta channel marked bad), 2 of 5 rats still count (MS13 R = -0.315, P = 4.6e-4).

    Attempt 01: partially reproduced. A difference in the power measure. The earlier attempt used the code's spectrogram power and found one rat (MS10); the blind attempt uses per-session normalised Hilbert power and finds MS13 and MS21, with 3 rats under raw Hilbert power and 1 under spectral power.

    Deviations from the paper’s method
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
    • Power is normalised by each session's pre mean before averaging over sessions (the reading of fig2h); raw and spectral power are shown.
    • The lab's theta channel of MS13-171130 is marked bad in the electrodes table; it is used, and the result without that session is shown.
  • Reproduced

    Running speed decreased relatively monotonically within a session, over the entire session.

    Aligned mean speed against trial: Spearman -0.873 (P = 1.2e-38, 120 trials).

    Results, Effects of MS cooling on single neuron properties, paragraph 3; Figure 4E; Figure 6C; Figure S5D, Efig4e-speed-decreases-within-session
    From the paper

    Running speed decreased relatively monotonically within session ( Fig. 4e ; see also Fig. 5c ).

    Result

    Aligned mean speed against trial: Spearman -0.873 (P = 1.2e-38, 120 trials). Per session Spearman of speed with trial number negative in 50 of 51 (median -0.445), signed-rank P = 7.4e-10; median per rat -0.34 to -0.50.

  • Reproduced

    In the sessions of Figure 5, mean running speed was 87.3 +- 8.0 in control trials (pre and post combined) and 86.2 +- 9.9 during MS cooling.

    Sessions with place cell pairs (23, which are also those with pairs in every state): control 80.3 +- 9.2 and…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 2was not reproduced in attempt 01fig5-speed-control-cooling
    From the paper

    we combined trials before and after cooling into a single control group (mean running speed = 87.3±8.0). During MS cooling (mean running speed = 86.2±9.9)

    Result

    Sessions with place cell pairs (23, which are also those with pairs in every state): control 80.3 +- 9.2 and cooling 77.1 +- 12.5 cm/s over all frames; 81.0 +- 9.2 and 78.1 +- 12.1 above 10 cm/s; both within tolerance.

    Attempt 01: not reproduced. A difference in the sessions. The earlier attempt used 15 of the code's 18 Figure 5 sessions, and its cooling speed was 0.3 cm/s below the tolerance under reading (b); the blind attempt uses the 23 sessions with place cell pairs, which the added curated units of version 0.261115.0311 make possible, and finds 80.3 and 77.1 cm/s, both within tolerance.

    Deviations from the paper’s method
    • The paper's 18 and 10 sessions cannot be told apart; the 23 sessions with pairs are used.
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
  • Reproduced

    Firing rates of pyramidal cells before and during MS cooling were strongly correlated (R = 0.7, P < 1e-58).

    Within-field rates pre against cooling, linear scale: R = 0.658 (P = 1.2e-147, 1185 fields), within 0.63 to…

    Figure S2A, Brests on an assumptionsuppl2ab-rates-correlated
    From the paper

    Firing rates of pyramidal neurons within their place fields (A) and their peak firing rates (B) (top) and illustration of the rate changes before and during MS cooling. R = 0.7, P < 10-58.

    Reported statistics
    • R = 0.7, p < 10⁻⁵⁸
    Result

    Within-field rates pre against cooling, linear scale: R = 0.658 (P = 1.2e-147, 1185 fields), within 0.63 to 0.77; peak rates 0.619; log scales 0.49 to 0.57. The Figure 5 rule fields and 3 cm bins give 0.64 to 0.69 for within-field rates.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
  • Reproduced

    Firing rates of pyramidal cells and putative interneurons decreased immediately after MS cooling onset and their changes correlated with MS temperature, not with the delayed hippocampal temperature.

    Raw rates: interneurons (307 units, 23 sessions) fire 10.13 Hz on aligned trials 1 to 5 against 11.65 Hz…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 3; Figure S5G, Hsuppl5gh-rates-follow-temperature
    From the paper

    firing rates of both pyramidal cells and putative interneurons in the hippocampus decreased immediately after MS cooling and the changes correlated well with MS temperature change

    Result

    Raw rates: interneurons (307 units, 23 sessions) fire 10.13 Hz on aligned trials 1 to 5 against 11.65 Hz before onset (signed-rank P = 1.9e-6); pyramidal cells (1295 units) 1.80 against 2.03 Hz (P = 6.3e-16). The aligned mean rate correlates with MS temperature over 120 aligned trials of the measured sessions: R = 0.806 (P = 1.1e-28) and 0.532 (P = 4.0e-10). Normalised rates have lower medians on trials 1 to 5 (0.887 and 0.785 against 1.000; one-sided signed-rank P = 1.4e-4 and 2.4e-18) but higher means (1.08 and 1.28, pulled up by units with low pre rates), and their series do not correlate with temperature (R = 0.113, P = 0.22; R = 0.147, P = 0.11); the outcome holds under the raw-rate reading. 307 interneurons is within 287 to 351; 1295 pyramidal cells is above 994 to 1214, from 23 sessions against 19. The hippocampal temperature comparison is not made (no hippocampal temperature in the dandiset).

    Deviations from the paper’s method
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • The paper's session subsets (53, 21, 19, 18 and 10 sessions) are not named; all sessions that hold the needed data are used.
  • Reproduced

    MS cooling decreased both the oscillation frequency of place cells (fp) and the LFP theta frequency in their fields (fLFP) by about the same degree, and both recovered (fLFP 8.4, 7.7, 8.5 Hz; fp 10.6, 9.5, 10.4 Hz before, during and after; n = 365).

    878 fields (of 1205 above 10 Hz) have an autocorrelogram peak in every state. fp 10.50, 9.64, 10.36 Hz; fLFP…

    Results, Effects of MS cooling on single neuron properties, paragraph 2; Figure 4Brests on an assumptionfig4b-fp-flfp-decrease
    From the paper

    MS cooling decreased both f p and f LFP , measured within the place fields of neurons, by approximately the same degree ... Both values recovered after cooling.

    Reported statistics
    • comparison marked *** in Figure 4B: p < 5.9 × 10⁻⁸ (n = 365 place fields)
    Result

    878 fields (of 1205 above 10 Hz) have an autocorrelogram peak in every state. fp 10.50, 9.64, 10.36 Hz; fLFP at the spikes 8.27, 7.62, 8.43 Hz; all six within tolerance; cooling against pre P = 1.9e-75 (fp) and 1.6e-101 (fLFP). fLFP over the time in the field is 8.53, 7.81 and 8.63 Hz, also within. Every other reading (Figure 5 rule fields, 3 cm bins, 12 min states) also puts all six within tolerance. 878 fields against the paper's 365. Every rat shows the decrease.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
  • Reproduced

    The spatial scale of the population vector correlation of pyramidal cells was not affected by MS cooling.

    Scale of the population vector decorrelation (distance where it drops to 0.5), mean of the two arms, 23…

    Results, Effect of MS cooling on place field features, paragraph 3; Figure 3G, H, Ifig3hi-population-vector-unchanged
    From the paper

    Population vector correlation of pyramidal cells was not affected by MS cooling ( Fig. 3g , h ).

    Result

    Scale of the population vector decorrelation (distance where it drops to 0.5), mean of the two arms, 23 sessions: median 24.0 cm pre, 25.9 cooling, 24.1 post; median change -0.05 cm, signed-rank P = 0.73. Two sessions with few cells (MS10-170307, MS22-180628) have cooling scales above 100 cm.

    Deviations from the paper’s method
    • Vectors are compared along the linearized maze within each arm's runs (the claims file's standard choice).
    • The paper used 21 sessions, not named; all 23 sessions with typed pyramidal cells are used.
  • Reproduced

    Running speed correlated with theta power.

    Reading (a), all 7087 trials: mean speed against raw Hilbert theta power R = 0.071 (P = 2.7e-9); normalised…

    Results, Effects of MS cooling on single neuron properties, paragraph 3; Figure 4F; Figure S2Hfig4f-speed-theta-power
    From the paper

    The animal's speed correlated with both theta power and f p ( Fig. 4f , g ).

    Result

    Reading (a), all 7087 trials: mean speed against raw Hilbert theta power R = 0.071 (P = 2.7e-9); normalised power R = 0.023 (P = 0.049); normalised spectral power R = 0.004 (P = 0.73). Reading (b), per rat: 3 of 5 rats (raw), 4 of 5 (normalised Hilbert or spectral) with P < 0.05; MS10 is not significant with raw or normalised Hilbert power and negative with normalised spectral power (R = -0.123, P = 7.2e-6), so with that measure 3 of the 4 significant rats are positive. The sign is positive. The criterion asks for one reading; the R of reading (a) is small (0.071) and its P rests on 7087 trials.

    Deviations from the paper’s method
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
  • Reproduced

    Over trials, mean theta frequency correlated positively with mean running speed before, during and after MS cooling, with the largest changes at 10 to 40 cm/s.

    Hilbert frequency against trial speed: R = 0.360 (pre), 0.259 (cooling), 0.387 (post), all P below 1e-33.

    Results, Effects of MS cooling on single neuron properties, paragraph 3; Figure S2E, Gsuppl2e-trial-speed-theta-frequency
    From the paper

    This comparison showed a positive correlation before, during and after MS cooling with the largest changes taking place at lower running speeds (10 to 40 cm/s; Suppl. Fig. 2e ).

    Result

    Hilbert frequency against trial speed: R = 0.360 (pre), 0.259 (cooling), 0.387 (post), all P below 1e-33. Slope over trials of 10 to 40 cm/s against above 40: pre -0.0043 against 0.0166 (14 slow trials), cooling 0.0685 against 0.0104 (12), post 0.0505 against 0.0164 (32): larger in 2 of 3 states. Spectral frequency: larger in 3 of 3. Only 61 of 7087 trials are below 40 cm/s, so the low-speed slopes rest on few trials.

    Deviations from the paper’s method
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
  • Reproduced

    The period of the summed phase cross-correlograms of place cell pairs was shorter than one theta cycle (2 pi), as place cells oscillate faster than LFP theta.

    Summed phase cross-correlogram period, pair reading (a): 1.87 pi pre (9291 pairs) and 1.91 pi cooling; reading…

    Figure 5Erests on an assumptionfig5e-phase-period-below-2pi
    From the paper

    Similar to d but instead of time lags, within-theta phase lags between spikes were calculated. Vertical dashed line indicates that the oscillation frequency of the spike cross-correlation is faster than that of f LFP (2π).

    Result

    Summed phase cross-correlogram period, pair reading (a): 1.87 pi pre (9291 pairs) and 1.91 pi cooling; reading (b): 1.83 and 1.86 pi. All below 2 pi.

    Deviations from the paper’s method
    • Phase cross-correlograms use the unwrapped Hilbert phase of the theta channel, for spike pairs within 400 ms.
    • Assumption: fields are found on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state; the paper does not say on which map (STAR Methods, Place cell analysis).
  • Reproduced

    Theta phase lags between place cell pairs were not affected by MS cooling (P > 0.24 between all conditions).

    Lag reading (a), the largest peak within pi of zero: |phase lag| pre against cooling P = 0.37 (8451 pairs)…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 3; Figure 5Irests on an assumptionwas not reproduced in attempt 01fig5i-phase-lags-unchanged
    From the paper

    In contrast, phase lags between spikes of place cell pairs were not affected by MS cooling ( Fig. 5i ; P > 0.24 between all conditions).

    Reported statistics
    • Wilcoxon signed rank test, p > 0.24
    Result

    Lag reading (a), the largest peak within pi of zero: |phase lag| pre against cooling P = 0.37 (8451 pairs), cooling against post P = 0.41, pre against post P = 0.50 (pair reading b: 0.068, 0.084, 0.59). Lag reading (b), the peak nearest zero: pre against cooling P = 2.7e-8 (0.47 against 0.50 rad) and pre against post P = 0.0065. The outcome rests on reading (a); the readings give different outcomes. Without MS13-171130 (theta channel marked bad), lag reading (a) gives P = 0.37, 0.62 and 0.71 (pair reading b, pre against cooling P = 0.040).

    Attempt 01: not reproduced. A difference in the pairs. Both take the largest peak within pi of zero and compare absolute lags; the earlier attempt found cooling lags larger than pre (P = 0.0015), and the blind attempt, with 8451 pairs from fields on maps over all trials and the cell types and added curated units of version 0.261115.0311, finds no change (P = 0.37). The blind attempt's nearest-peak reading gives a change (P = 2.7e-8), so the outcome rests on how the lag is read.

    Deviations from the paper’s method
    • Assumption: the phase lag of a pair is the largest peak of the phase cross-correlogram within pi of zero (lag reading a), the theta-scale lag that the claims file reads for fig5h; the nearest-peak reading (b) picks small side peaks of the smoothed correlogram. The paper does not say which peak (Results, MS temperature effects on theta time/phase compression, paragraph 3).
    • Assumption: fields are found on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state; the paper does not say on which map (STAR Methods, Place cell analysis).
    • The lab's theta channel of MS13-171130 is marked bad in the electrodes table; it is used, and the result without that session is shown.

Partially reproduced19

  • Partially reproduced

    A session holds about 40 control trials, then about 20 to 60 cooling trials and 20 to 80 recovery trials, 80 to 200 trials in all with a mean of 150.

    51 sessions, mean 142.4 trials (within 135 to 165), range 37 to 204; MS10-170307 has 37 trials, outside 72 to…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; STAR Methods, Electrophysiological Recordingswas reproduced in attempt 01session-structure
    From the paper

    After a block of control trials (~ 40 trials), dry ice was placed into the reservoir ... about 20 to 60 'cooling' trials), followed by recovery trials (20 to 80).

    Result

    51 sessions, mean 142.4 trials (within 135 to 165), range 37 to 204; MS10-170307 has 37 trials, outside 72 to 220. Median pre trials 39 (36 to 44); median cooling and post trials 45 and 46 (lab labels), 49 and 50 (12 min), 41 and 58 (10 min), all inside 18 to 66 and 18 to 88. The criterion's partial rule (mean holds, one part fails) applies.

    Attempt 01: reproduced. A change in the claims file and in the sessions. The earlier attempt used the 45 sessions of a list from the paper's unlinked code, which leaves out MS10-170307; the rewritten claims file drops that list, and the blind attempt uses all 51 sessions, where MS10-170307 has 37 trials, outside 72 to 220. The mean (143.8 and 142.4) and the median pre trials (39 in both) agree.

    Deviations from the paper’s method
    • The paper reports 53 sessions; the dandiset holds 51.
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
  • Partially reproduced

    MS cooling typically peaked about 60 s after its onset and lasted about 10 to 12 minutes, about 50 trials.

    Over 31 measured sessions the median time from onset to the minimum (within 5 min) is 109.7 s, outside 40.5 to…

    STAR Methods, Electrophysiological Recordingscooling-time-course
    From the paper

    The cooling typically peaked after about 60 sec after the cooling onset ( suppl. fig. 1G ) and lasted for about 10–12 minutes, corresponding to approximately 50 trials

    Result

    Over 31 measured sessions the median time from onset to the minimum (within 5 min) is 109.7 s, outside 40.5 to 66 s (by rat 38 to 124 s). Duration reading (a), time until the temperature is again within 1 C of the pre median, has a median of 11.7 min (within 9 to 13.2); reading (b), the lab's cooling interval, 8.1 min. The median number of trials in the lab's first cooling interval is 32, inside the Results' 18 to 66 but not 45 to 55; 47.5 trials fall within duration (a). Two of the three parts hold. Without the two flat 2018-07-19 sessions the medians are 109.7 s and 11.8 min.

    Deviations from the paper’s method
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • The minimum is searched within 5 min of the dataset's onset time stamp, as the criterion says; 13 sessions have a second cooling epoch and only the first is used.
  • Partially reproduced

    Theta frequency decreased linearly with MS temperature, down to 20 C (R = 0.81, P = 5.4e-48).

    Reading (a), aligned trials -40 to 80 averaged over 29 to 31 measured sessions: R = 0.978 (Hilbert; P =…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 2; Figure 2Gwas reproduced in attempt 01fig2g-theta-freq-temperature
    From the paper

    Theta frequency decreased linearly with MS temperature ( Figure 2g ; down to 20° C; R = 0.81; P = 5.4 × 10 −48 )

    Reported statistics
    • R = 0.81, p = 5.4 × 10⁻⁴⁸ (n = 53 sessions in 5 rats)
    Result

    Reading (a), aligned trials -40 to 80 averaged over 29 to 31 measured sessions: R = 0.978 (Hilbert; P = 4.3e-82, 120 points), 0.935 (spectral). Reading (b), 1 C bins: 0.959 and 0.929 (26 bins). Reading (c), pooled trials: 0.554 and 0.481 (4313 trials). Every reading is positive with P below 1e-10 and none is within 0.729 to 0.891. The pooled slope is 0.063 Hz per C; the lowest trial temperature is 17.1 C. The two flat 2018-07-19 sessions change R by at most 0.03.

    Attempt 01: reproduced. A difference in method. The earlier attempt used the code's aligned series of 198 positions over 37 sessions (R = 0.789); the blind attempt averages trials -40 to 80 over 29 to 31 sessions (120 points), which smooths more and gives R = 0.978, above the tolerance. The dataset also changed, as version 0.261115.0311 marks 11 series outside MS10 as modelled, so the blind attempt uses 31 measured sessions where the earlier one used 37.

    Deviations from the paper’s method
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
    • The aligned series spans trials -40 to 80 (standard choice; the paper does not say).
  • Partially reproduced

    MS cooling increased choice errors about 3-fold, within each rat (P < 0.05 for all animals) and across all animals (P = 1e-6).

    Lab states: 15.1% errors during cooling against 7.3% pre, signed-rank over 51 sessions P = 7.1e-6 (9.2e-7…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6D and 6Efig6d-errors-increase
    From the paper

    Overall, the number of memory errors increased approximately 3-fold, assessed either within rats (P < 0.05 for all animals) or across all animals (P = 10 −6

    Reported statistics
    • within each rat: p < 0.05
    • across all animals: p = 10⁻⁶
    • boxplots over all sessions (Figure 6E, marked **): p < 10⁻⁷
    Result

    Lab states: 15.1% errors during cooling against 7.3% pre, signed-rank over 51 sessions P = 7.1e-6 (9.2e-7 against pre and post), below 1e-5. The ratio is 1.86 to 2.25 over the readings, outside 2.7 to 3.3. Per rat with lab states, MS10, MS12, MS21 and MS22 give P = 0.003 to 0.048; MS13 (5 sessions, rank-sum over trials) P = 0.23 to 0.44 under every reading.

    Deviations from the paper’s method
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
  • Partially reproduced

    The incidence of errors correlated negatively with MS temperature (R = -0.35, P < 0.01, all animals).

    Reading (a), aligned trials: R = -0.636 (P = 5.9e-15), smoothed -0.869; reading (b), pooled trials: R = -0.153…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6F and 6Jfig6f-errors-temperature
    From the paper

    The incidence of errors negatively and significantly correlated with temperature change (R = − 0.35; P < 0.01; all animals)

    Reported statistics
    • R = − 0.35, p < 0.01 (n = all animals)
    Result

    Reading (a), aligned trials: R = -0.636 (P = 5.9e-15), smoothed -0.869; reading (b), pooled trials: R = -0.153 (P = 4.9e-24, 4313 trials); reading (c), per rat unsmoothed: MS12 -0.204 (P = 0.026), MS13 -0.276 (0.002), MS21 -0.520, MS22 -0.402. All negative with P < 0.01 under (a) and (b); none within -0.385 to -0.315. MS10 has no measured temperature.

    Deviations from the paper’s method
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
  • Partially reproduced

    The incidence of errors correlated negatively with theta frequency (R = -0.35, P < 0.01, all animals).

    Hilbert frequency: reading (a) R = -0.707 (P = 1.8e-19), smoothed -0.912; reading (b) -0.116 (P = 1.5e-22…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6G and 6Jfig6g-errors-theta-frequency
    From the paper

    The incidence of errors negatively and significantly correlated with ... theta frequency (R = − 0.35; P < 0.01; all animals)

    Reported statistics
    • R = − 0.35, p < 0.01 (n = all animals)
    Result

    Hilbert frequency: reading (a) R = -0.707 (P = 1.8e-19), smoothed -0.912; reading (b) -0.116 (P = 1.5e-22, 7087 trials); reading (c) per rat -0.391, -0.303, -0.384, -0.536, -0.421, all P < 0.001. Only MS13 is within tolerance, and (c) needs every rat; no reading puts R within -0.385 to -0.315. The spectral frequency gives -0.680, -0.060 and -0.26 to -0.45.

    Deviations from the paper’s method
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
  • Partially reproduced

    Error rates correlated best with theta frequency, in correlations and partial correlations, and had no significant relationship to running speed.

    Hilbert measures over 120 aligned trials of the measured sessions: R of errors with temperature -0.636…

    From the paper

    Partial correlation values (top) and P values (bottom) for each comparison (right panels). Note error rates correlate best with theta frequency and have no significant relationship to running speed.

    Result

    Hilbert measures over 120 aligned trials of the measured sessions: R of errors with temperature -0.636, frequency -0.652, power -0.257, speed 0.026 (P = 0.78); partial R 0.040, -0.214 (P = 0.020), -0.007 and 0.211 (P = 0.023). Frequency is largest in both, but speed's partial correlation is significant. With the spectral measures temperature is largest in both (-0.636; partial -0.253).

    Deviations from the paper’s method
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • The partial correlation of each measure controls for the other three, as the claims file reads the panel.
  • Partially reproduced

    Within-field and peak firing rates of place cells decreased moderately during MS cooling (11% and 12%; P < 1e-9 and P < 1e-11).

    5 cm bins, fields above 10 Hz (1186 fields): within-field rate decrease 0.4% (median), 4.0% (of the mean), P =…

    Results, Effects of MS cooling on single neuron properties, paragraph 2; Figure S2A, Brests on an assumptionsuppl2-place-cell-rates-decrease
    From the paper

    Both within-field and peak firing rates of place cells decreased moderately during MS cooling ( Suppl. Fig. 2 ; 11% and 12%; P < 10 −9 and P < 10 −11 , respectively

    Reported statistics
    • within-field firing rate: p < 10⁻⁹
    • peak firing rate: p < 10⁻¹¹
    Result

    5 cm bins, fields above 10 Hz (1186 fields): within-field rate decrease 0.4% (median), 4.0% (of the mean), P = 0.12; peak rate 2.9% and 5.6%, P = 7.1e-4. With 3 cm bins both are significant (within-field 1.2% and 4.7%, P = 0.039; peak 4.4% and 5.5%, P = 1.7e-4). No reading puts either near 11 or 12%. One P is below 1e-6, the peak rate with 3 cm bins and the Figure 5 rule fields (P = 6.2e-7). The mean of per-field decreases is negative (-73 to -287%), driven by fields with near-zero pre rates. By rat the decrease of the mean ranges from -11% (MS12) to 25% (MS10).

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
    • The paper's session subsets (53, 21, 19, 18 and 10 sessions) are not named; all sessions that hold the needed data are used.
  • Partially reproduced

    Firing rates of interneurons decreased during MS cooling by about 14%, about the same degree as place cells.

    Narrow waveform interneurons (194 units with a pre rate): decrease 4.2% (median of per-unit decreases), 8.7%…

    Discussion, Theta phase organization of hippocampal cell assemblies, paragraph 5; Results, Effects of MS cooling on single neuron properties, paragraph 2; Figure S2Cdisc-interneuron-rates-decrease
    From the paper

    within-field firing rates of place cells decreased by a similar proportion (12%; interneurons 14%).

    Result

    Narrow waveform interneurons (194 units with a pre rate): decrease 4.2% (median of per-unit decreases), 8.7% (of the mean), signed-rank P = 0.023; narrow and wide (276 units): 3.1% and 8.0%, P = 0.11. Above 10 cm/s: 4.2% and 7.8% (P = 0.065). None is within 12.6 to 15.4%. The mean of per-unit decreases is negative (-109 to -131%), driven by units with near-zero pre rates. Pyramidal cells: 7.1% and 6.1%, P = 5.3e-4.

    Deviations from the paper’s method
    • Interneurons are the curated units typed Narrow Interneuron (and Wide Interneuron) by the lab's CellExplorer file.
    • States are the dataset's trial labels (Pre, Cooling, Post), with the claims file's 12 and 10 min readings as variants; cooling onset is the time stamp of the dataset's cooling table.
  • Partially reproduced

    fp and fLFP were correlated across place fields before, during and after cooling (R = 0.61, 0.59 and 0.36; P < 1e-6 each), with the range of fp larger than that of fLFP.

    R of fp and fLFP over 878 fields, fLFP at spikes: 0.248, 0.426, 0.238 (P below 1e-12); over the time in the…

    Figure 4C; Results, Effects of MS cooling on single neuron properties, paragraph 2rests on an assumptionfig4c-fp-flfp-correlation
    From the paper

    Correlation between LFP theta frequency ( f LFP ) and place cell oscillation frequency ( f p ; R pre = 0.61; R cooling = 0.59; Rpost = 036; P < 10 −6 each)

    Reported statistics
    • each of before, during and after cooling: R pre = 0.61; R cooling = 0.59; Rpost = 036, p < 10⁻⁶
    Result

    R of fp and fLFP over 878 fields, fLFP at spikes: 0.248, 0.426, 0.238 (P below 1e-12); over the time in the field: 0.364, 0.442, 0.310. Every reading is positive with P below 1e-11, but no reading puts all three within tolerance (pre is 0.21 to 0.36 against 0.61). SD of fp exceeds SD of fLFP in pre and cooling (1.21 against 0.67 Hz, 1.03 against 0.53 Hz).

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
  • Partially reproduced

    fLFP and fp measured within place fields decreased linearly with MS temperature (fLFP R = 0.66, slope 0.071 Hz per C; fp R = 0.38, slope 0.09 Hz per C).

    Reading (b), field and state (2070 values): with fLFP over the time in the field, R = 0.685 and slope 0.068 Hz…

    Results, Effects of MS cooling on single neuron properties, paragraph 1; Figure 4Arests on an assumptionfig4a-frequency-temperature-slopes
    From the paper

    The theta oscillation frequency of pyramidal neurons decreased linearly and paralleled the downward frequency shift of LFP theta oscillation ( Fig. 4a ; f LFP : R = 0.66, Slope = 0.071. f p : R = 0.38, slope = 0.09).

    Result

    Reading (b), field and state (2070 values): with fLFP over the time in the field, R = 0.685 and slope 0.068 Hz per C (both within tolerance); with fLFP at the spikes R = 0.403, 0.059 Hz per C; fp R = 0.301, slope 0.067 Hz per C (both below tolerance). Reading (a), field and trial (41304 passes, 31216 with fp): fLFP R = 0.184, slope 0.058; fp R = 0.155, slope 0.054. Both slopes positive with P below 1e-30 under every reading; no reading puts all four in tolerance.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • fp per trial needs at least 2 in-field spikes and an autocorrelogram peak; 10088 of 41304 passes have none.
  • Partially reproduced

    Place field size and fp were negatively correlated before, during and after cooling (R = -0.49, -0.40, -0.40; P < 1e-9), with similar slopes and a slightly lower intercept during cooling.

    R of size and fp over 878 fields: pre -0.181 (P = 7.0e-8), cooling -0.204 (P = 1.1e-9), post -0.141 (P =…

    Figure 3D; Results, Effect of MS cooling on place field features, paragraph 1rests on an assumptionfig3d-size-fp-negative
    From the paper

    Place field size continues to be inversely correlated with f p after MS cooling (R pre = − 0.49; R cooling = − 0.40; R post = − 0.40. P < 10 −9 all conditions).

    Reported statistics
    • each of before, during and after cooling: R pre = − 0.49; R cooling = − 0.40; R post = − 0.40, p < 10⁻⁹
    Result

    R of size and fp over 878 fields: pre -0.181 (P = 7.0e-8), cooling -0.204 (P = 1.1e-9), post -0.141 (P = 2.8e-5); slopes -7.6, -9.9 and -7.1 cm per Hz, intercepts 156, 173 and 153 cm (the cooling intercept is higher). All negative with P < 0.05; none within tolerance; P is above 1e-9 in all three states (cooling 1.1e-9); 3 cm bins give -0.15 to -0.18.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
  • Partially reproduced

    The phase precession slope decreased slightly but significantly during MS cooling (P < 0.007 and P < 0.0003).

    Slopes searched over plus and minus 2 cycles per field (8 to 10% at the bound), 1044 fields with at least 10…

    Results, Effects of MS cooling on single neuron properties, paragraph 2; Figure 4Drests on an assumptionfig4d-precession-slope-decrease
    From the paper

    decreased slightly, but nevertheless significantly, during MS cooling ( Fig. 4d ).

    Reported statistics
    • comparison marked ** in Figure 4D: p < 0.007
    • comparison marked *** in Figure 4D: p < 3 × 10⁻⁴
    Result

    Slopes searched over plus and minus 2 cycles per field (8 to 10% at the bound), 1044 fields with at least 10 spikes in each state: median -5.60, -5.30, -5.50 rad per field. Magnitude reading, cooling against pre: median change of |slope| -0.13, signed-rank P = 0.016 (flatter during cooling); against post P = 0.073. Signed reading P = 0.065 and 0.069. 3 cm bins: magnitude P = 0.0041 and 0.083, signed P = 0.056 and 0.0062; 12 min states: no comparison below 0.05. One comparison holds under the main reading, so the criterion's partial rule applies; no reading gives both. With a range of 1 cycle (the first run), 23 to 32% of the slopes sit at the bound and no comparison is significant (P 0.054 to 0.94); with 3 cycles at most one comparison per reading is significant. The outcome rests on the slope range, which the paper does not give, and on the 8 to 10% of fields whose slope sits at the 2-cycle bound: without them (840 fields) no comparison is significant (cooling against pre P = 0.090 for |slope|, 0.077 signed; against post 0.20 and 0.080). With 3 cycles the significant comparison is the signed slope against post (P = 0.037), while against pre |slope| gives P = 0.149. The flattening against pre is weak evidence.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • Position is scaled to the field (0 to 1), so slopes are in radians per field; at least 10 spikes per field and state (standard choice).
    • Assumption: the circular-linear regression searches slopes within plus and minus 2 cycles per field; the paper gives no range (STAR Methods, Theta phase and phase precession). 1 and 3 cycles are shown as variants; 1 cycle pins many slopes at its bound.
  • Partially reproduced

    The phase precession slope had a low but significant correlation with MS temperature (R = -0.027, P = 7.67e-19).

    Reading (a), field and trial with at least 5 spikes, slopes within plus and minus 2 cycles per field (18% at…

    Figure S3Erests on an assumptionsuppl3e-precession-temperature
    From the paper

    Phase precession slope as a function of MS temperature. All values from before, during and after MS cooling trials are combined. Note low (R = -0.027) but significant (P = 7.67e-19) correlation.

    Reported statistics
    • R = -0.027, p = 7.7 × 10⁻¹⁹
    Result

    Reading (a), field and trial with at least 5 spikes, slopes within plus and minus 2 cycles per field (18% at the bound): R = -0.0262 (within -0.0297 to -0.0243), P = 3.2e-6 over 31617 values, not below 1e-10. Reading (b), field and state: R = -0.0274, P = 0.22 (1993 values). Negative with P < 0.05 under (a). With a range of 1 cycle, R = -0.0273 (P = 1.2e-6) and -0.0243 (P = 0.28), the same outcome. The paper's P implies about 1e5 values; here there are 3e4, from 12 measured sessions with fields.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • Temperature analyses use the 31 sessions with a measured MS temperature; the other 20 hold the lab's modelled curve, described in the files as not a measurement. Values outside 5 to 45 C are set to NaN (standard choice); no remaining sample within the trials is below 15 C, so the rail values near 5 and 10 C do not enter any trial value.
    • A per-trial slope needs at least 5 in-field spikes (standard choice).
    • Assumption: per-trial slopes are searched within plus and minus 2 cycles per field, as in fig4d-precession-slope-decrease; 1 cycle is a variant.
  • Partially reproduced

    fp depended on running speed more strongly than fLFP, so fp - fLFP increased with speed, and fp during cooling was lower at all velocities.

    10 cm/s bins, states pooled, 5435 field-bins of 1148 fields: fp slope 0.0106 Hz per cm/s (P = 2.7e-60), fLFP…

    Results, Effects of MS cooling on single neuron properties, paragraph 3; Figure 4G and 4Hrests on an assumptionwas reproduced in attempt 01fig4gh-fp-speed
    From the paper

    f p changes during MS cooling could not be explained by decreased running velocity of the rat because f p values during cooling were lower at all velocities ( Fig. 4g ).

    Result

    10 cm/s bins, states pooled, 5435 field-bins of 1148 fields: fp slope 0.0106 Hz per cm/s (P = 2.7e-60), fLFP slope 0.0045 (P = 3.4e-55), bootstrap 95% interval of the difference 0.0044 to 0.0076. Median fp during cooling is below pre in 11 of 14 speed bins with at least 10 fields (not in the 0, 30 and 120 cm/s bins). The 20 cm/s variant: lower in 8 of 8, slope difference 0.0055 to 0.0095.

    Attempt 01: reproduced. A change in the claims file, which now fixes 10 cm/s speed bins with 20 cm/s as a variant. The earlier attempt used 20 cm/s bins and found fp lower during cooling in every bin it could test; the blind attempt finds it lower in 11 of 14 bins of 10 cm/s and in 8 of 8 bins of 20 cm/s.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • Bootstrap over fields with 500 resamples and a fixed seed.
  • Partially reproduced

    Theta cycles were consistently longer during MS cooling at every position on the track and returned to control duration after cooling, and the duration profile did not correlate with the speed profile along the track.

    Median cycle duration over 50 sessions: 117.6 ms pre, 130.4 cooling, 117.6 post; cooling longer than pre (48…

    Results, Effects of MS cooling on single neuron properties, paragraph 3; Figure S3B, Dsuppl3-theta-cycle-duration
    From the paper

    While theta duration was consistently longer during MS cooling trials, duration distribution did not correlate with the speed distribution on the track ( Suppl. Fig. 3 ).

    Result

    Median cycle duration over 50 sessions: 117.6 ms pre, 130.4 cooling, 117.6 post; cooling longer than pre (48 of 50, P = 1.2e-9) and post (49 of 50, P = 1.1e-9); post against pre P = 0.96. Cooling is longer in 100% of 42 (left) and 65 (right) position bins. The pre duration and speed profiles correlate over bins (R = -0.43, P = 0.0047; R = -0.32, P = 0.0089), so the last part fails.

    Deviations from the paper’s method
    • Theta is taken on the lab's theta channel (electrodes column theta_reference); the Methods say only 'An LFP channel located in CA1' (Theta phase and phase precession).
    • Position bins need at least 50 cycles per state (standard choice).
  • Partially reproduced

    The theta-repeated cross-correlograms of place cell pairs had a period of about 85 ms before cooling, shorter than the LFP theta period (about 110 ms), and the period lengthened during MS cooling in each session (P = 0.002), while the period of the phase cross-correlograms was unaffected (P = 0.32).

    Pair reading (a), 9482 usable pre pairs: summed cross-correlogram period 108.1 ms, outside 76.5 to 93.5 ms…

    Figure 5D and 5F; Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 2rests on an assumptionfig5d-ccg-period
    From the paper

    Duration of the theta-repeated spike cross-correlograms (as in d ), calculated for each session, significantly increased during MS cooling ... whereas the spike phase-lag correlations remained unaffected (n.s., P = 0.32).

    Reported statistics
    • period of the time cross-correlograms, cooling against control (pre and post): two-sided signed rank test, p = 0.002
    • period of the phase cross-correlograms, cooling against control: p = 0.32
    Result

    Pair reading (a), 9482 usable pre pairs: summed cross-correlogram period 108.1 ms, outside 76.5 to 93.5 ms, below the LFP theta period of 120.9 ms; pre and post combined 109.6 ms. Per session (23, all with pairs in every state) the period is 108.3 ms in control and 120.0 ms in cooling, longer in 19, signed-rank P = 0.0049; the phase period does not change (1.86 against 1.84 pi, P = 0.31). Reading (b): 104.5 ms pooled, 105.9 against 115.8 ms per session (P = 0.042), phase P = 0.32. The surface-fit period b (fig5cg) is 108.9 ms pooled. The spacing of the peaks of the summed pre cross-correlogram (after removing its slow trend; peaks with at least 10% prominence within 300 ms) is 107.2 ms (5 peaks; 102.5 ms from the central peak to its neighbours) with pair reading (a) and 103.5 ms with (b), also outside 76.5 to 93.5 ms.

    Deviations from the paper’s method
    • Fields follow the Figure 5 rule (peak above 8 Hz); they are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • A pair is used in a state when its cross-correlogram holds at least 20 spike pairs within 200 ms; each pair's cross-correlogram is scaled to unit sum before summing; the period is that of the largest Fourier component of the detrended sum (standard choices; the paper gives none). 12834 overlapping pairs in 23 sessions against the paper's 2948 in 18 sessions.
  • Partially reproduced

    During MS cooling the theta time lags between place cell pairs increased compared with before and after cooling (P = 8.0e-5 and P = 0.00032), and did not differ between before and after (P = 0.79).

    Lag reading (a), pair reading (a): |lag| 27 ms pre, 30 ms cooling, 27 ms post; cooling against pre P = 1.9e-31…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 3; Figure 5Hrests on an assumptionwas reproduced in attempt 01fig5h-time-lags-increase
    From the paper

    During MS cooling, the time lags increased significantly ( Fig. 5h ; P < 10 −4 ; sign rank test; n = 10 sessions), whereas they were not different from each other during precooling and post-cooling sessions (P = 0.79)

    Reported statistics
    • pre against cooling: sign rank test, p = 8 × 10⁻⁵ (n = 10 sessions, 4 rats)
    • post against cooling: sign rank test, p = 3.2 × 10⁻⁴ (n = 10 sessions, 4 rats)
    • pre against post: sign rank test, p = 0.79 (n = 10 sessions, 4 rats)
    Result

    Lag reading (a), pair reading (a): |lag| 27 ms pre, 30 ms cooling, 27 ms post; cooling against pre P = 1.9e-31 (8506 pairs), against post P = 9.3e-45; pre against post P = 0.034. Pair reading (b): P = 2.5e-37, 3.2e-61 and 0.0082. Lag reading (b), nearest peak: pre against cooling P = 1.6e-13, post against cooling 5.5e-4, pre against post 6.9e-5. Under every reading the signed-rank tests of both cooling comparisons are significant and pre and post also differ; under lag reading (b) the median lag is 16 ms in both post and cooling (pair reading a, rank-sum P = 0.85), so a longer cooling lag is not shown there. The rank-sum variant gives pre against post P = 0.16 (pair reading a). Pairs share cells and sessions; over sessions (median |lag| per session and state, 23 sessions, a variant), lag reading (a) gives cooling longer than pre (27 against 30 ms, 16 of 23, P = 0.014) and post (P = 0.012) and pre against post P = 0.98 (pair reading b, 0.016, 0.014 and 0.79); lag reading (b) gives 0.23, 0.040 (cooling shorter than post) and 0.95. The criterion fixes the test over pairs, so the outcome stays partial.

    Attempt 01: reproduced. A difference in the pairs. Both find cooling lags longer than pre and post; the blind attempt has 8506 pairs against 3136, from fields on maps over all trials and the added curated units of version 0.261115.0311, and with them pre and post also differ (P = 0.034, earlier P = 0.0967).

    Deviations from the paper’s method
    • The test is the signed-rank over pairs, as the claims file reasons from P below 0.002 with 10 sessions.
    • Assumption: fields are found on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state; the paper does not say on which map (STAR Methods, Place cell analysis).
  • Partially reproduced

    The theta oscillation frequency of putative fast spiking interneurons decreased with MS cooling, as did that of pyramidal cells, by about 14% on average, and pyramidal cells oscillated faster than interneurons.

    Running spikes (above 10 cm/s), cooling against pre: narrow interneurons (145 units with a peak in both…

    Results, Effects of MS cooling on single neuron properties, paragraph 1; Figure S2Drests on an assumptionwas reproduced in attempt 01suppl2d-interneuron-oscillation-slows
    From the paper

    Note that pyramidal neurons oscillate faster than interneurons and the theta frequency oscillation of both interneurons and pyramidal cells decreases with MS cooling by approximately 14% on average.

    Result

    Running spikes (above 10 cm/s), cooling against pre: narrow interneurons (145 units with a peak in both states) median 8.93 to 8.40 Hz, decrease 8.7% (median), 6.9% (of the mean), 6.4% (mean of decreases), signed-rank P = 6.4e-13; narrow and wide (191) 8.7%, 6.6%, 5.8%, P = 1.0e-14; pyramidal fields (974) 10.42 to 9.52 Hz, 8.6%, 8.2%, 7.5%; pooled 8.6%, 8.0%, 7.2%. None within 12.6 to 15.4%. Pyramidal cells oscillate faster than interneurons before cooling (10.42 against 8.93 Hz). 116 of 307 interneurons and 249 of 1223 fields have no autocorrelogram peak in a state and are dropped.

    Attempt 01: reproduced. A change in the claims file, which now carries the 14% decrease of Figure S2D. Both attempts find a significant decrease of interneuron oscillation frequency (9.4% earlier, 8.7% in the blind attempt), neither within 12.6 to 15.4%.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • Interneuron spikes are all trial spikes above 10 cm/s ('across the whole maze', Figure S2D).

Not reproduced8

  • Not reproduced

    The incidence of errors did not correlate with the running speed of the rat (R about 0.1, P > 0.05 for all animals).

    Per rat over aligned trials, error incidence against mean trial speed: MS10 R = -0.276 (P = 0.0023) and MS13 R…

    Results, MS cooling increases behavioral errors, paragraph 1; Figure 6I and 6Jfig6i-errors-not-speed
    From the paper

    and not with the running speed of the rat (R ~ 0.1; P > 0.05 for all animals

    Reported statistics
    • R ~ 0.1, p > 0.05 (n = all animals)
    Result

    Per rat over aligned trials, error incidence against mean trial speed: MS10 R = -0.276 (P = 0.0023) and MS13 R = -0.328 (P = 0.00026) are significant; MS12 -0.158 (0.085), MS21 -0.068 (0.46), MS22 -0.150 (0.10). Pooled over sessions the aligned R is -0.146 (P = 0.11); over pooled trials -0.172 (P = 2.6e-49). Speed above 10 cm/s gives the same two rats. The correlations are negative, not about +0.1.

  • Not reproduced

    During MS cooling fp and fLFP decreased in parallel, so the difference fp - fLFP remained constant.

    fp - fLFP (at the spikes) is 2.22 Hz pre, 2.02 cooling and 1.93 post; median change cooling - pre -0.14 Hz…

    Discussion, Theta phase organization of hippocampal cell assemblies, paragraph 3; Results, Effects of MS cooling on single neuron properties, paragraph 2rests on an assumptionfig4ac-fp-flfp-difference-preserved
    From the paper

    However, during MS cooling f p and f LFP decreased proportionally (i.e., f p – f LFP difference remained constant)

    Result

    fp - fLFP (at the spikes) is 2.22 Hz pre, 2.02 cooling and 1.93 post; median change cooling - pre -0.14 Hz, signed-rank P = 1.1e-6 over 878 fields (fLFP over time: 1.97, 1.83, 1.74 Hz, P = 2.0e-4). The paper's own means give 2.2, 1.8 and 1.9 Hz, a decrease of the same direction; the default test over this many fields detects it.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
  • Not reproduced

    Place field size was highly correlated before and during MS cooling (R = 0.91), and did not change.

    R of field size (contiguous bins above 10% of the state's peak) pre against cooling: 0.465 (1193 fields, 5…

    Results, Effect of MS cooling on place field features, paragraph 1; Figure 3Crests on an assumptionwas reproduced in attempt 01fig3c-field-size-correlated
    From the paper

    Place field size does not change with MS cooling (R = 0.91).

    Result

    R of field size (contiguous bins above 10% of the state's peak) pre against cooling: 0.465 (1193 fields, 5 cm), 0.490 (12 min states), 0.410 (3 cm), all below the partial threshold of 0.5. Median size 60 cm in both states, median change 0 cm, signed-rank P = 0.082 (P = 7.3e-6 under the 12 min states).

    Attempt 01: reproduced. A difference in method. The earlier attempt measured size on each state's map within 4 bins of the field found on running frames, over 635 fields, with R = 0.8197 at the edge of the tolerance; the blind attempt measures contiguous bins above 10% of the state's peak on maps of all frames, over 1193 fields with cell types from the files, and finds R = 0.465.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
  • Not reproduced

    Measured place field size correlated with the size predicted by S = v / (fp - fLFP) before (R = 0.55), during (R = 0.54) and after (R = 0.11) cooling.

    R of measured size with v / (fp - fLFP) per state, under the four readings of v and fLFP and three field sets…

    Results, Effect of MS cooling on place field features, paragraph 2; Figure 3Erests on an assumptionwas partially reproduced in attempt 01fig3e-model-field-size
    From the paper

    We found a reliable and similar relationships between measured place field sizes and model-predicted sizes for trials before (R = 0.55), during (R = 0.54) and after (R = 0.11) MS cooling

    Result

    R of measured size with v / (fp - fLFP) per state, under the four readings of v and fLFP and three field sets: pre -0.032 to 0.059 (P >= 0.088), cooling -0.004 to 0.134, post -0.022 to 0.127. Pre is neither within tolerance nor positive with P < 0.05 under any reading; 7 to 37 fields with fp <= fLFP are left out per state.

    Attempt 01: partially reproduced. A difference in method, the field and size definitions of fig3c-field-size-correlated. The earlier attempt found R pre 0.246 (P = 4.7e-06); the blind attempt finds pre R between -0.032 and 0.059 under its readings.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
  • Not reproduced

    The information content of place cell spikes was not altered by MS cooling (P > 0.26).

    Skaggs information per map (cell and arm), 908 maps with a field above 10 Hz (5 cm bins, lab states): pre to…

    Results, Effect of MS cooling on place field features, paragraph 2; Figure 3Frests on an assumptionfig3f-information-unchanged
    From the paper

    Information content of place cell spikes was also left unaltered by MS cooling (P > 0.26; Fig. 3f ).

    Reported statistics
    • p > 0.26
    Result

    Skaggs information per map (cell and arm), 908 maps with a field above 10 Hz (5 cm bins, lab states): pre to cooling median change -0.015 bits per spike, signed-rank P = 0.35; cooling to post -0.015 (P = 0.078); pre to post -0.038 (P = 0.0054). The pre to post comparison is significant, so the claim of absence fails on the paper's test. The other field sets and bins give pre to post P = 4e-6 to 0.0054 and pre to cooling P = 0.0075 to 0.35. With the trials of each state subsampled to the same number per arm (median 17, 20 draws), which removes the upward bias of Skaggs information with fewer data: pre to cooling P = 0.22, cooling to post P = 0.22, pre to post median change -0.030, P = 0.016 (902 maps; P = 0.0047 with the Figure 5 rule fields). Equal trials do not mean equal data, as speed falls within sessions (median occupancy per arm 58 s pre, 72 s cooling and post). With the spikes of each state subsampled to the same number (median 171; 848 maps with at least 20 spikes in every state, fields above 10 Hz), pre to post still falls (median change -0.025, P = 0.032; 0.024 with the Figure 5 rule fields). With the information corrected by subtracting that of a uniform-rate map with the same spikes and occupancy (estimated bias, median 0.056 bits per spike pre, 0.049 cooling, 0.040 post), no comparison is significant (pre to post median change -0.022, P = 0.085 and 0.074; pre to cooling P = 0.75 and 0.70; cooling to post P = 0.18 and 0.12). The outcome follows the criterion's measure, Skaggs information without correction; part of the pre to post decrease is the difference in estimated bias (medians 0.056 against 0.040), and what remains is not significant.

    Deviations from the paper’s method
    • Place fields of Figures 3 and 4 follow the claims file's reading (b), the Figure 5 rule of the Methods (Place cell analysis) with a peak above 10 Hz, as the paper's fields were drawn by hand and the dandiset holds none; fields are drawn on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state (assumption; the paper does not say on which map). Rate maps use all frames of the trials and a Gaussian smoothing of 1 bin SD (standard choice).
    • Information is computed on the arm's map of each cell with a field, once per map.
    • Equal-trial information: the trials of each state and arm are subsampled without replacement to the smallest state count, 20 times, and the information averaged (standard correction, shown as a variant).
    • Equal-spike and shuffle-corrected information (variants): the spikes of each state are subsampled to the smallest state count, 20 times; and the information minus the mean of 20 maps with the same spike count placed in proportion to the occupancy. Maps with fewer than 20 spikes in a state are left out (standard choices).
  • Not reproduced

    The fraction of place cells active in a given theta cycle was not significantly affected by MS cooling (P = 0.2).

    Over 82574 theta cycles of 22 sessions with pairs and LFP: fraction of place cells active per cycle 0.189 pre…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 4; Figure 5Jrests on an assumptionfig5j-fraction-active-unchanged
    From the paper

    we found that the fraction of place cells active in a given theta cycle was not significantly affected by MS cooling ( Fig. 5j ; P = 0.2).

    Reported statistics
    • as given in the Results: p = 0.2
    • pre against cooling (legend): p = 0.28
    • post against cooling (legend): p = 0.006
    • pre against post (legend): p = 5 × 10⁻⁴
    Result

    Over 82574 theta cycles of 22 sessions with pairs and LFP: fraction of place cells active per cycle 0.189 pre, 0.200 cooling, 0.205 post; rank-sum pre against cooling P = 1.6e-25 (effect +0.011, +5.7%); post against cooling P = 6.6e-10; pre against post P = 4.1e-65. The fraction of all units gives P = 2.2e-38. Cycles share cells and sessions; per-session means (a variant) do not differ from pre to cooling (median change -0.0007, higher in cooling in 9 of 22, signed-rank P = 1.0), the comparison the criterion judges, while post is higher than cooling (P = 0.0029) and pre (P = 0.00059). The criterion fixes the rank-sum over cycles, so the outcome stands; under the per-session variant it would be reproduced.

    Deviations from the paper’s method
    • Place cells are the cells with a Figure 5 field in the session.
    • Assumption: fields are found on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state; the paper does not say on which map (STAR Methods, Place cell analysis).
  • Not reproduced

    The number of spikes emitted by all neurons per theta cycle was preserved during MS cooling (P > 0.058 between all conditions).

    Spikes of all curated units per cycle: 30.8 pre, 31.1 cooling, 35.2 post; rank-sum pre against cooling P =…

    Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 4; Figure 5Krests on an assumptionfig5k-spikes-per-cycle-unchanged
    From the paper

    The number of spikes emitted by all neurons per theta cycle was also preserved after MS cooling ( Fig. 5k )

    Reported statistics
    • p > 0.058
    Result

    Spikes of all curated units per cycle: 30.8 pre, 31.1 cooling, 35.2 post; rank-sum pre against cooling P = 4.9e-7, cooling against post P = 1.8e-39, pre against post P = 5.8e-65. Per-session means (a variant) do not differ from pre to cooling (median change -0.26, signed-rank P = 0.80) but differ from cooling to post (P = 0.0047) and pre to post (P = 0.0059), so the claim of absence fails per session too.

    Deviations from the paper’s method
    • Assumption: fields are found on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state; the paper does not say on which map (STAR Methods, Place cell analysis).
  • Not reproduced

    The waveforms of hippocampal action potentials were not affected by MS cooling.

    Subset of 4 sessions (MS12-170715, MS13-171130, MS21-180627, MS22-180629), 263 units with at least 20 spikes…

    Results, MS cooling decreases hippocampal theta frequency and power, paragraph 3; Figure S1Gsuppl1g-waveforms-unchanged
    From the paper

    Finally, the waveforms of action potentials in the hippocampus ... were not affected by MS cooling ( Suppl. Fig. 1g ).

    Result

    Subset of 4 sessions (MS12-170715, MS13-171130, MS21-180627, MS22-180629), 263 units with at least 20 spikes in both conditions: trough-to-peak latency median 0.80 ms in both, median change +0.05 ms (5.9%), signed-rank P = 1.1e-9 (2 of 4 sessions significant on their own); peak-to-peak amplitude 144.7 against 146.5 uV, median change +0.65 uV (0.7%), P = 0.026. Latency is quantised at 0.05 ms (20 kHz), so the change is one sample. On the mean waveforms interpolated by a cubic spline to 200 kHz, the latency is 0.79 against 0.82 ms, median change +0.035 ms (4.8%), P = 3.1e-11, significant in each of the 4 sessions (P = 9.9e-7 to 0.043). Units have a median of 158 spikes in the control blocks and 115 in the cooling blocks (at least 20 each).

    Deviations from the paper’s method
    • The dandiset holds no unit waveforms; mean waveforms are measured from the 20 kHz wide-band signal, high-pass 300 Hz, on each unit's largest channel, in two 52 s blocks of pre, three of cooling and two of post per session, on one session per rat (not MS10). The whole wide-band signal (3 TB) does not fit the run.

Blocked2

  • Blocked

    Distance-time compression of place cell pairs (0.54 cm/ms before cooling) decreased during MS cooling (P = 0.02), while distance-phase compression was unchanged (P = 0.92).

    The surface fit of the Methods fails on this density under both readings of its equation.

    Methods underspecifiedFigure 5C and 5G; Results, MS temperature effects on theta time/phase compression of place cells sequences, paragraph 2was not reproduced in attempt 01fig5cg-compression
    From the paper

    Compression index, c (cm/ms; i.e., the slope in c ), significantly decreased during MS cooling (* P = 0.02) but the distance/phase lag compression (cm/radian) remained unaffected (P = 0.92).

    Reported statistics
    • distance-time compression, cooling against control: p = 0.02
    • distance-phase compression, cooling against control: p = 0.92
    Result

    The surface fit of the Methods fails on this density under both readings of its equation. With curve_fit, most fits stop at the evaluation limit: reading (a) converges in 9 of 23 sessions in each condition and in both for 5 (pair reading b, 12, 16 and 10); reading (b) in 2 and 6, in both for none. Converged fits explain less than the density's mean (pooled pre R2 -0.135 under reading (a), pair reading (a); per session median R2 -0.10 to -5.1), while the envelope alone (the two Gaussian factors, no oscillation), which the surface nests, has a per-session median R2 of 0.41 to 0.68; these fits are stuck short of the best fit. A bounded fit with several starts, b held within 30% of the summed period and started from the envelope's own fit, does no better: pooled pre R2 -0.138 and -2.58 (readings a and b, pair reading a), -1.46 and -5.84 (pair reading b), against 0.80 and 0.57 for the envelope; per session (reading a, pair reading a) none of 46 fits reaches the envelope and 9 exceed R2 0. The equation's oscillation term takes the density to zero between its ridges, while the density's theta modulation is small: half its peak-to-trough range is 6.7% of the trend at zero lag (4.3% with pair reading b; 1.5 to 19% per distance bin). The paper does not say how the density was prepared for the fit (a detrending or a baseline would change this) nor give the grid, start values or procedure, so no choice has a defensible basis. Variants that are not the criterion's measure show no decrease: the density's ridge slope, 0.556 cm/ms pooled, is 0.566 in control and 0.628 cm/ms in cooling per session (P = 0.62; 0.623 against 0.616 with pair reading b, P = 0.71); the converged curve_fit per-session fits give P = 0.81 (5 sessions) and 1.0 (10); the bounded per-session fits give a median a of 0.981 against 0.674 cm/ms (P = 0.052), from fits below the envelope; the least-squares slope of Ltr on the main lag P = 0.67 and 0.36. The first run recorded not_reproduced on the curve_fit fits.

    Attempt 01: not reproduced. A change in the claims file, which now requires the surface fit of the Methods. The earlier attempt measured compression by a regression of lag on distance (0.273 cm/ms); the blind attempt found that the surface fit does not fit the density under either reading of the equation and blocked the claim as methods_underspecified.

    Deviations from the paper’s method
    • The grid (5 cm by 1 ms over 100 cm and 400 ms) and start values (ridge slope of the density, summed period, c 60 cm, d 150 ms) are standard choices the paper does not give; curve_fit is limited to 3000 evaluations.
    • Bounded variant: least squares with bounds (b within 30% of the summed pre period, |a| from 0.01 to 50), started from the envelope's own fit and from a = 0.3, 0.55 and 1.0 cm/ms of either sign (5, 10 and 20 cm/rad on the phase axis), keeping the best start (standard choices).
    • The equation's fraction bars are lost in the extracted text; the claims file's two readings are run.
    • Assumption: fields are found on the map over all trials of an arm, states pooled, so that a field has the same boundaries in every state; the paper does not say on which map (STAR Methods, Place cell analysis).
  • Blocked

    In a control experiment, hippocampal temperature fell by less than 1.5 C at the largest MS temperature decrease (16 C), and later than the MS (MS maximum at about 45 s, time constant 11 s; hippocampus peak at 115 s, time constants 48 s right and 72 s left).

    The control experiment with MS and hippocampal temperature (Figure S1H to K) is not in the dandiset: the files…

    Data missing from the datasetResults, MS cooling decreases hippocampal theta frequency and power, paragraph 3; Figure S1H to Ksuppl1-hippocampal-temperature
    From the paper

    found < 1.5° C decrease in the hippocampus at the time of the largest MS temperature decrease (16° C) ... (maximum effect at approximately 45 s; time constant: 11 s), the mild temperature decrease in the hippocampus was considerably delayed (peak at 115 s; time constant 48 s for the right hippocampus, and 72 s for the left)

    Result

    The control experiment with MS and hippocampal temperature (Figure S1H to K) is not in the dandiset: the files hold only the septal probe's measured temperature or the lab's modelled curve, and no epoch is a temperature control session. It is not public elsewhere as far as the paper says (no other repository is named).

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Selection not documentedNewThe paper reports 53 sessions in 5 rats and subsets of 21, 19, 18 and 10 sessions, and 365 place fields, without naming them; the dandiset holds 51 sessions, so the subsets cannot be matched.#
  • Methods not availableNewQuestion for the authors: which peak of a pair's phase cross-correlogram is its phase lag (Figure 5I)? The largest peak within pi of zero gives no change with cooling (P >= 0.37), the peak nearest zero a change (P = 2.7e-8); the attempt assumed the first.#
  • Methods not availableNewThe surface equation of the Methods (Spatial temporal compression) has lost its fraction bars in the available text, and the preparation of the density, the grid, start values and fitting procedure are not given. Under both readings the equation's oscillation term takes the density to zero between ridges, while the density's theta modulation is about 4 to 7% of its level, and the fits, also bounded and from several starts, explain less than the density's mean, so the compression of Figure 5C and G could not be measured (fig5cg blocked). The fitting code would let it be repeated.#
  • Methods not availableNewQuestion for the authors: on which rate map were the place fields of Figure 5 found by the automatic rule (the map over all trials, over control trials, or per state)? The attempt assumed the map over all trials of an arm, so that each field has the same boundaries in every state; the outcomes of the place field claims rest on it.#
  • Methods not availableNewPlace fields of Figures 3 and 4 were defined by hand; the field boundaries, or the list of the 365 fields, would let the field claims be tested on the paper's fields.#
  • Methods not availableNewQuestion for the authors: within what range was the circular-linear regression slope of phase precession searched (Figure 4D, S3E)? With a range of 1 cycle per field about 30% of the slopes sit at the bound and no change with cooling is found; with 2 cycles, the attempt's assumption, precession is flatter during cooling than before (P = 0.016) but not than after (P = 0.073), and without the slopes at the bound neither comparison is significant.#
  • Paper inconsistentStill presentfound on promptThe legend of Figure 5H gives P = 8.0e-5 by a sign rank test with N = 10 sessions; an exact signed-rank test over 10 sessions cannot give a P below 0.00195, so the test must be over pairs or the N refers to something else.#
  • Paper inconsistentStill presentfound on promptThe Discussion gives a 12% decrease of LFP theta frequency during cooling, while the Results give within-field LFP theta of 8.4 Hz before and 7.7 Hz during cooling, a decrease of 8.3%.#

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Cooling of the medial septum and hippocampal theta coordination (Petersen and Buzsaki 2020)

Tests the findings of Petersen and Buzsaki (2020) on dandiset 000059, which holds 51 sessions of 5 rats running a figure-8 maze while the medial septum was cooled, with CA1 LFP, curated units, head tracking and the septal temperature. It tests the effects of cooling on theta frequency and power, choice errors, running speed, place cell rates, oscillation frequency, field features, phase precession and the theta time and phase lags of place cell pairs. The hippocampal temperature of the paper's control experiment is not in the dandiset. All files

Environment: Python 3.13, 20 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-15
    Agreed with 45 of 45 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The first executed notebook with the conclusion cells and the summary removed, the helper module ms_cooling.py and the claims file, with the paper's full text. The verifier tested circ_lin_slope and the cross-correlogram period on synthetic inputs and checked the archive's asset list and metadata for the blocked claim; it did not re-run anything on the data. Its outcome table lists 45 claims and gives none for suppl2d-interneuron-oscillation-slows.
  • Round 2
    2026-11-18
    Agreed with 46 of 46 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2: the full executed notebook of the revision after round 1, with its conclusions and Summary, the helper module, the README, the attempt record and the claims file, with the paper. Its report is transcripts/petersen-2020/verifier-2-report.md. It agreed with all 46 outcomes. Its points on the data check and the Summary, which concern no single claim, were answered as follows: the behaviour descriptions give 120, 40 or 30 Hz and match the timestamps in every session (now printed per session), so the tracking-rate metadata_error is withdrawn and cell 5 and the Summary corrected; the raw temperature range (-1751 to 1354 C), the theta frequencies of the 2018-07-19 sessions and the end of the second cooling interval of MS12-170717 and MS12-170718 are now printed in the data check.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

Provenance

Attempt record
petersen-2020-02
Paper
Cooling of Medial Septum Reveals Theta Phase Lag Coordination of Hippocampal Cell Assemblies
Date
2026-11-15
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:000059 (on DANDI)
Version
0.261115.0311 (doi:10.48324/dandi.000059/0.261115.0311)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-15

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 17 findings reproduced, Petersen et al. 2020

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/petersen-2020/"><img src="https://encorescience.org/badge/papers/petersen-2020.svg" alt="Encore: 17 findings reproduced, Petersen et al. 2020"></a>

Or as Markdown:

[![Encore: 17 findings reproduced, Petersen et al. 2020](https://encorescience.org/badge/papers/petersen-2020.svg)](https://encorescience.org/papers/petersen-2020/)

The same numbers are in this page’s JSON, under badge (how it is counted).