The counts are 14 VEN and 21 PC, as stated. The VEN median is lower under all eight readings, but significance differs between them. Rank-sum p is 0.045 (a1b1c1) and 0.025 (a1b1c2), and 0.077 to 0.29 under the six others, so by the criterion the claim is blocked. Both significant readings keep each patch's holding current in the measure, but the other two a1 readings, over all steps, do not find the effect (a1b2c1 p = 0.27, a1b2c2 p = 0.18). Under the code's example reading (a2 b1 c1), VEN 30.4 against PC 38.1 pA, p = 0.10. By session under that reading, VEN is lower in HS (15.9 against 40.3 pA, 7 and 11 cells, p = 0.0028) and not in AS (40.7 against 36.2 pA, 7 and 10 cells, p = 0.60). In the code table's values VENs are lower in both sessions (HS 12.4 against 31.5 pA, p = 0.0028; AS 17.5 against 29.1 pA, ratio 0.60, p = 0.11), so only the significance rests on HS. The AS reversal under a2 b1 c1 is mostly the artefact, not a session effect. Under that reading, the only one for which widths were computed, the maximum is a brief transient in 10 cells (6 of 14 VENs, 4 of 21 PCs), and 9 of them are in AS (5 of its 7 VENs, 4 of its 10 PCs; the one in HS is HS1c18). Three AS VEN transients are 3 to 5 times the table's value (AS4c14 70.7 against 15.5 pA, AS3c11 87.7 against 17.5, AS1c1 42.1 against 13.8). Without the transient cells AS keeps 2 VENs and 6 PCs (37.2 against 34.3 pA, p = 0.86), too few to tell, and HS keeps its difference (15.6 against 40.3 pA, p = 0.0019). In variants that are not readings of the paper and decide nothing, a 4-pole Bessel low-pass run once forward as an amplifier's filter acts (2.9, 5 or 10 kHz, cut-offs fixed in advance) and a 0 to 3 ms window, 13 of the 24 baseline-subtracted variants give p < 0.05, every a2 reading at 2.9 kHz, every one with the short window, and a2b1c2 at 5 kHz. The paper's code table gives 14.9 against 29.3 pA, p = 0.001, and the smoothed variant 16.0 against 29.9 pA, p = 0.0008, but that variant was fitted to the table. The t-test variant gives p = 0.013 to 0.96 over the readings. Whether the criterion should include a filtered reading is asked of a reader (questions/001750.yaml). Current density cannot be computed, as no capacitance is stored. Question for the paper's authors (finding methods_unavailable) is how the maximal current was measured from the traces. It asks which baseline was used, whether the traces were filtered or the peak fitted, and over which steps and window. Two of the four readings that subtract no baseline find the effect (a1b1c1, a1b1c2), and none with the code's own baseline subtraction does, unless the trace is filtered, smoothed or the window cut short.