Papers / Fedele et al. 2020

Fedele et al. 2020 · NeuroImage

The relation between neuronal firing, local field potentials and hemodynamic activity in the human amygdala in response to aversive dynamic visual stimuli

Tommaso Fedele, Athina Tzovara, Bettina K. Steiger, Peter Hilfiker, Thomas Grünwald, Lennart Henning Stieglitz, Hennric Jokeit, Johannes Sarnthein

Outcomes of 25 claims

  • 4 partially reproduced
  • 12 not reproduced
  • 9 blocked

Summary: Most main findings did not hold up in this data, and the BOLD findings could not be tested. The sustained delta decrease outside the seizure onset zone appeared under some z-scorings and not others, as the paper does not say how power was z-scored. The onset increase in high gamma power was not found, and the high gamma modulation index did not separate seizure onset zone amygdalae, though the paper does not state the window it used. Firing did not increase in all neurons during aversive videos (27 of 42 units did). The BOLD correlations need fMRI time courses that the dataset does not hold.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Fedele, Tzovara et al. (2020) from dandiset 000576 18 Open in Colab

Partially reproduced4

  • Partially reproduced

    DELTA power is reduced (negative MI) in 12 of the 14 amygdalae, whether inside or outside the SOZ.

    Of the 6 readings that define all 14 delta MIs, 5 give 11 or 12 negative with negative MIs inside and outside…

    Results 2.1, paragraph 3; Table 2verifier disagreed at firstrests on an assumptiontable2-delta-reduced-12-of-14
    From the paper

    DELTA power was reduced in 12 of 14 amygdalae (negative MI in Table 2), irrespective of whether the amygdalae were within the SOZ or not

    Result

    Of the 6 readings that define all 14 delta MIs, 5 give 11 or 12 negative with negative MIs inside and outside the SOZ (baseline z-scoring with both group windows and the fixed window, 11, positive in amygdalae 2, 10 and 11; z-scoring over the amygdala with the all-14 group window and the fixed window, 12, positive in 2 and 10). Z-scoring over the trial with the fixed window, the first reading the criterion lists that defines them and given as measured, gives 10 (positive in 2, 9, 10 and 11), so the count is not in range under every reading. Table 2 has amygdalae 2 and 4 positive. The per-amygdala window defines 1 or 2 delta MIs. The variants give 10 to 13.

    Deviations from the paper’s method
    • MI readings as in table2-mi-values; z-scorings as in fig1b-delta-decrease.
    • Assumption. The only reading that fails uses window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, taken from the Results' text (Results 2.1, Methods 4.11) and not from the claims file. The claims file's window readings that define all 14 delta MIs (group clusters under baseline z-scoring in both sets and under z-scoring over the amygdala in all 14) give 11, 11 and 12, all in range. So the outcome rests on counting window (c) as a reading. The question is for the authors (methods_unavailable, MI window).
  • Partially reproduced

    Spike sorting gave 50 putative neuron clusters from 9 amygdalae, of which 41 had a firing rate above 1 Hz and were analysed.

    The dandiset holds 42 units, 42 above 1 Hz over the epochs each was recorded in (reading a, given as measured)…

    Results 2.3, paragraph 1; Methods 4.9neuron-count
    From the paper

    We identified 50 putative clusters of neurons (Niediek et al., 2016) from 9 amygdalae and included those with firing rate >1 Hz (N 1⁄4 41 neurons) in further analysis

    Result

    The dandiset holds 42 units, 42 above 1 Hz over the epochs each was recorded in (reading a, given as measured) and 40 over the whole 442 s (reading b); both within 4.1 of 41. The 50 putative clusters cannot be tested, as only units above about 1 Hz were deposited. Units are in 8 amygdalae, not 9, so the third expected value fails. The measured value is the first expected value only. The units come from 5 patients (1, 2, 3, 4, 7), which matches the abstract's 5 participants, but not the amygdalae of Table 1, which lists MUA for patients 5 and 8 and none for 7. Their mean rate over the observed epochs is 4.65 +- 3.91 Hz (median 3.13), against the data descriptor's 1.66 +- 2.65 Hz; 31 units are above 2 Hz.

    Deviations from the paper’s method
    • Epochs in which a unit has no spike at all are taken as not recorded (16 units of subject 7 after epoch 11, 4 units of subject 2 in epoch 1), as their rates elsewhere are 1 to 16 Hz.
  • Partially reproduced

    Across neurons, the correlation of firing rate with macro-electrode HGP does not differ between the AVERSIVE and NEUTRAL conditions.

    The readings of the claims file disagree; the claimed absence holds in 4 of 6.

    Results 2.3, paragraph 3; Figure 3B, lower boxplotverifier disagreed at firstfig3b-firing-hgp-no-condition-difference
    From the paper

    Across all neurons, the covariation of neuronal firing with HGP was not significantly different between the two experimental conditions (Spearman’s r 1⁄4 0.17 ... �0.28 in AVERSIVE, 0.18 �0.18 in NEUTRAL; Wilcoxon paired test, p > 0.05)

    Reported statistics
    • Wilcoxon paired test, p > 0.05 (n = 41 neurons)
    Result

    The readings of the claims file disagree; the claimed absence holds in 4 of 6. Per block and averaged no time base finds a difference (p 0.72 to 0.83), nor does the 1 s time base over the blocks laid end to end (r = 0.085 +- 0.130 in AVERSIVE and 0.094 +- 0.124 in NEUTRAL, p = 0.54, given as measured). Over the blocks laid end to end on the 1.5 s and 15 s time bases, each block smoothed on its own, the test finds NEUTRAL higher (p = 0.012 and 0.023, median differences -0.087 and -0.131). Smoothing over the whole session first (the first revision's form, now a variant) gave p = 0.002 and 0.009. The means are within the stated spreads under every reading. Partially reproduced and not blocked, because the six readings are named by the claims file, so no method detail is left to choose; the test ran under each, and the claimed absence holds under some and fails under others, that is, it holds only in part. Unlike the criteria of fig1b-delta-decrease and fig1f-hgp-more-specific-than-delta, this criterion does not say to block when its readings disagree. The time base is still asked of the authors (methods_unavailable).

    Deviations from the paper’s method
    • In the readings with the blocks laid end to end, each block is smoothed (or binned) on its own before concatenation, so no sample carries another block or a baseline clip.
    • HGP is the Methods 4.8 envelope without per-trial normalisation; a per-block Spearman r is unchanged by any per-trial normalisation.
  • Partially reproduced

    Across neurons, the ongoing firing rate correlates positively with muHGP (0.27), HGP (0.19) and BOLD (0.23), and the correlation is lowest with HGP.

    The firing-HGP Spearman r is 0.136 +- 0.241 with 15 s smoothing (reading a, given as measured) and 0.139 +…

    Results 2.3, paragraph 5; Figure 3D and its insetuses data from outside the datasetfig3d-firing-correlations-modalities
    From the paper

    Across all neurons and participants, the ongoing firing rate positively correlated with μHGP (Spearman’s r 1⁄4 0.27 �0.15), HGP (Spearman’s r 1⁄4 0.19 � 0.17) and BOLD (Spearman’s r 1⁄4 0.23 �0.20) ... Across all recording modalities, the correlation of the firing rate and other measures was lowest with HGP (Wilcoxon’s paired test, p < 1e-2)

    Reported statistics
    • correlation with HGP against those with muHGP and with BOLD: Wilcoxon paired test, p < 0.01 (n = neurons, number not given (BOLD exists only for the amygdalae with fMRI))
    Result

    The firing-HGP Spearman r is 0.136 +- 0.241 with 15 s smoothing (reading a, given as measured) and 0.139 +- 0.195 on the 1.5 s time base, positive in 29 and 32 of 42 units, within 0.19 +- 0.17. The muHGP and BOLD correlations and the two tests that HGP is lowest cannot be computed, as the microwire signals and the BOLD time courses are not available. The measured value is the HGP mean, the second expected value; the first and third cannot be measured.

    Deviations from the paper’s method
    • Only the HGP part is tested.

Not reproduced12

  • Not reproduced

    High gamma power (above 60 Hz) is higher during AVERSIVE than during NEUTRAL sequences in the first 2 s of the sequence.

    None of the 12 mixed-model readings and none of the 12 unpaired t-test readings of the claims file finds a…

    Results 2.1, paragraph 1; Figure 1Cfig1c-hgp-increase-first-2s
    From the paper

    The HGP was enhanced in response to aversive stimuli during the first 2 s of the AVERSIVE sequence presentation (Fig. 1C, unpaired t-tests, corrected for multiple comparisons using random permutations, p < 0.05)

    Reported statistics
    • unpaired t-tests, corrected for multiple comparisons using random permutations (Results); linear mixed model with cluster-based permutation (Methods 4.11), p < 0.05
    Result

    None of the 12 mixed-model readings and none of the 12 unpaired t-test readings of the claims file finds a significant HGP cluster, nor do the two z-scoring variants. The largest mixed-model t in the first 2 s is 3.01 at 0.95 s after onset (baseline z-scoring, nSOZ amygdalae), above the threshold at 13 time points, and its cluster has permutation p 0.062; the smallest cluster p of all mixed-model readings is 0.056. With the HGP band limited to 60-150 or 60-250 Hz (variants of the open upper edge) the only significant HGP clusters are AVERSIVE above NEUTRAL from about 6 to 8 s (p 0.020 and 0.042) and, with baselinepool, 3.1 to 4.7 s, not in the first 2 s. Among the baselines of Methods 4.8 (variants), the previous epoch as baseline with z-scoring over the amygdala gives an HGP cluster from 0.6 to 5.5 s in the nSOZ amygdalae (p 0.002); as blocks alternate, that baseline is always a block of the other condition. With the trialsd variant two more HGP clusters begin in the first 2 s, both in the nSOZ amygdalae, 0.6 to 1.9 s with the mean of all epochs as baseline (p 0.028) and 0.5 to 8.4 s with the previous epoch (p 0.002). These three are the only HGP clusters that begin in the first 2 s, and all use a baseline other than the 1 s clip. Per-amygdala time courses are in the notebook.

    Deviations from the paper’s method
    • As fig1b-delta-decrease. HGP is a 60 Hz high-pass (the claims file's reading); two band-pass variants are shown and do not decide the outcome.
  • Not reproduced

    No AVERSIVE against NEUTRAL difference is found in the theta, alpha, beta and gamma (30-60 Hz) bands.

    The readings of the claims file disagree.

    Results 2.1, paragraph 1; bands in Methods 4.8rests on an assumptionother-bands-no-effect
    From the paper

    Since no effect was observed in the other spectral bands (see Methods 7.8), in the following we focus on DELTA power and HGP

    Result

    The readings of the claims file disagree. Under the z-score over the whole trial no band has a cluster, nor has delta. Under baseline z-scoring the mixed model finds clusters with AVERSIVE below NEUTRAL in alpha in the 7 nSOZ amygdalae (13.3 to 15.9 s, p 0.016) and in theta and alpha in all 14 (p 0.002 to 0.028); under z-scoring over the amygdala all four bands have clusters in all 14 and none in the nSOZ amygdalae. Every reading that shows the delta effect of Fig. 1B (6 of 12) shows a cluster in another band. Of the variants, baselinepool in the nSOZ amygdalae shows the delta effect and no other-band cluster; in all 14 it has theta and alpha clusters.

    Deviations from the paper’s method
    • Assumed that the paper's pipeline is one under which its own delta result (Fig. 1B) appears, as the paper reports the delta effect and the absence in other bands from the same analysis (Results 2.1, paragraph 1). The outcome is judged on the readings of the claims file that show the delta effect; the trial reading shows no cluster in any band, delta included. The first revision adopted baseline z-scoring alone; the verifier found that the author's own choice, and it is no longer used.
    • Outcomes are judged on the three z-scorings of the claims file (trial, baseline, amygdala). Two variants are shown and enter no count of readings, trialsd (the baseline-corrected envelope divided by its SD in the trial) and baselinepool (the epoch's baseline mean and the SD of the baseline clips pooled over the amygdala's epochs, a stable form of baseline z-scoring). The two other baselines of Methods 4.8 (mean of all epochs, previous epoch) are also run as variants.
    • As fig1b-delta-decrease for the test.
  • Not reproduced

    The modulation indices of DELTA and HGP for each of the 14 amygdalae are as printed in Table 2.

    No reading gives all 28 values within tolerance (at best 4 of 28 among the claims file's z-scorings, z-scoring…

    Table 2, columns Modulation index (MI) of iEEG, DELTA and HGPtable2-mi-values
    From the paper

    Not quoted: Values read from Table 2, which no sentence states one by one. Minus signs are garbled in the extracted text; the signs used here agree with the counts the Results give.

    Result

    No reading gives all 28 values within tolerance (at best 4 of 28 among the claims file's z-scorings, z-scoring over the amygdala with fixed windows; 6 with the trialsd variant) or all 28 signs (at best 23 of 28). The measured values are those of the first reading the criterion lists that defines all 28, z-scoring over the trial with fixed windows (1 of 28 within tolerance, 16 signs). The group cluster window defines no HGP MI, as there is no HGP group cluster; the per-amygdala clusters define 1 to 3 MIs per band. Re-mapping subjects 2 and 7, or 7 to the paper's 5 and 8, does not bring the values closer under the claims file's z-scorings (0 to 4 within tolerance); the trialsd variant goes from 6 to 5 and 7.

    Deviations from the paper’s method
    • Window readings (a) group clusters and (b) per-amygdala clusters are the claims file's; (c) fixed windows, 0 to 2 s for HGP and 0 to 24 s for delta, is taken from the Results' text ("occurred at stimulus onset in HGP and was sustained throughout the trial in DELTA", Results 2.1 paragraph 2; "HGP enhancement in the first 2 s or sustained delta decrease", Methods 4.11) and counted as a reading.
    • Where a window reading finds no significant window for an amygdala, its MI is undefined (the first revision set it to 0); a claim is judged on the readings that define every MI it needs.
    • Outcomes are judged on the three z-scorings of the claims file (trial, baseline, amygdala). Two variants are shown and enter no count of readings, trialsd (the baseline-corrected envelope divided by its SD in the trial) and baselinepool (the epoch's baseline mean and the SD of the baseline clips pooled over the amygdala's epochs, a stable form of baseline z-scoring). The two other baselines of Methods 4.8 (mean of all epochs, previous epoch) are also run as variants.
  • Not reproduced

    Across the 14 amygdalae, the DELTA modulation index and the HGP modulation index are negatively correlated.

    Only window (c) defines both MIs. Under it r = -0.30 (p = 0.30), -0.12 (p = 0.69) and -0.12 (p = 0.68) for…

    Results 2.1, paragraph 2; Figure 1Drests on an assumptionfig1d-delta-hgp-mi-correlation
    From the paper

    MI and HGP-MI were negatively correlated across all amygdalae

    Reported statistics
    • Spearman correlation, r = -0.67, p = 0.01 (n = 14 amygdalae)
    Result

    Only window (c) defines both MIs. Under it r = -0.30 (p = 0.30), -0.12 (p = 0.69) and -0.12 (p = 0.68) for z-scoring over the trial, against the baseline and over the amygdala; the variants give -0.33 and -0.04. None is within tolerance or has p < 0.05. The printed Table 2 values give r = -0.74 (p = 0.003).

    Deviations from the paper’s method
    • MI readings as in table2-mi-values; z-scorings as in fig1b-delta-decrease.
    • Assumption. Window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, is the only window reading that defines the MIs this claim needs, so the outcome rests on it. It is taken from the Results' text (Results 2.1, Methods 4.11, "HGP enhancement in the first 2 s"), while the paper defines the MI over "the interval where the two curves are significantly separated" (Table 2 legend), which these data give for no HGP MI. The question is for the authors (methods_unavailable, MI window).
  • Not reproduced

    Among the 7 amygdalae outside the SOZ, the stronger the HGP enhancement (HGP MI), the stronger the reduction of DELTA power (more negative DELTA MI).

    Over the 7 nSOZ amygdalae, window (c) gives r = -0.57 (trial), -0.14 (baseline) and +0.07 (amygdala), negative…

    Results 2.1, paragraph 2; Table 2verifier disagreed at firstrests on an assumptionnsoz-delta-hgp-mi-inverse
    From the paper

    Specifically for amygdalae not included in the SOZ, we observed that the stronger the HGP enhancement, the stronger the reduction in DELTA power (Table 2)

    Result

    Over the 7 nSOZ amygdalae, window (c) gives r = -0.57 (trial), -0.14 (baseline) and +0.07 (amygdala), negative in 2 of the 3 readings that define the MIs, so not under every reading. Windows (a) and (b) define no HGP MI for these amygdalae. The variants give -0.07 and +0.21. The printed Table 2 values give r = -0.68 (p = 0.094).

    Deviations from the paper’s method
    • MI readings as in table2-mi-values; z-scorings as in fig1b-delta-decrease.
    • Assumption. Window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, is the only window reading that defines the MIs this claim needs, so the outcome rests on it. It is taken from the Results' text (Results 2.1, Methods 4.11, "HGP enhancement in the first 2 s"), while the paper defines the MI over "the interval where the two curves are significantly separated" (Table 2 legend), which these data give for no HGP MI. The question is for the authors (methods_unavailable, MI window).
  • Not reproduced

    All 7 amygdalae outside the SOZ have a positive HGP MI, while the response is absent in amygdalae within the SOZ (6 of 7 negative).

    Window (c) gives 4, 4 and 5 of 7 nSOZ amygdalae with a positive HGP MI and 3, 5 and 7 of 7 SOZ amygdalae with…

    Results 2.1, paragraph 3; Table 2 and its legendrests on an assumptiontable2-hgp-mi-positive-nsoz
    From the paper

    All amygdalae outside SOZ showed a positive HGP-MI in response to AVERSIVE videos, while this response was absent in amygdalae within the SOZ (p 1⁄4 0.009)

    Reported statistics
    • HGP MI, nSOZ against SOZ amygdalae: not named, p = 0.009 (n = 7 nSOZ and 7 SOZ amygdalae)
    Result

    Window (c) gives 4, 4 and 5 of 7 nSOZ amygdalae with a positive HGP MI and 3, 5 and 7 of 7 SOZ amygdalae with a negative one (trial, baseline, amygdala); no reading gives both counts. The measured values are those of the trial reading. Under z-scoring over the amygdala Fisher's test gives p = 0.021 but the nSOZ count is 5. Windows (a) and (b) define no HGP MI for all amygdalae.

    Deviations from the paper’s method
    • MI readings as in table2-mi-values; z-scorings as in fig1b-delta-decrease.
    • Assumption. Window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, is the only window reading that defines the MIs this claim needs, so the outcome rests on it. It is taken from the Results' text (Results 2.1, Methods 4.11, "HGP enhancement in the first 2 s"), while the paper defines the MI over "the interval where the two curves are significantly separated" (Table 2 legend), which these data give for no HGP MI. The question is for the authors (methods_unavailable, MI window).
  • Not reproduced

    The HGP MI, but not the DELTA MI, distinguishes amygdalae within the SOZ from those outside it.

    Under no reading that defines both MIs (window c) and neither test does the HGP MI differ between nSOZ and SOZ…

    From the paper

    HGP but not DELTA distinguishes between amygdalae within SOZ and outside SOZ (p 1⁄4 0.019, not corrected)

    Reported statistics
    • HGP MI, SOZ against nSOZ: not named, p = 0.019, not corrected-corrected (n = 7 nSOZ and 7 SOZ amygdalae)
    Result

    Under no reading that defines both MIs (window c) and neither test does the HGP MI differ between nSOZ and SOZ amygdalae at p < 0.05 (smallest p 0.084, baseline z-scoring, t-test); the DELTA MI does not differ either (p 0.08 to 0.95). With the baselinepool variant the rank-sum test gives HGP p = 0.035 and DELTA p = 0.48. Run on the printed Table 2 values the same tests give HGP p = 0.004 and 0.002 but also DELTA p = 0.035 and 0.013; asked in questions/000576.yaml.

    Deviations from the paper’s method
    • MI readings as in table2-mi-values; z-scorings as in fig1b-delta-decrease.
    • Assumption. Window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, is the only window reading that defines the MIs this claim needs, so the outcome rests on it. It is taken from the Results' text (Results 2.1, Methods 4.11, "HGP enhancement in the first 2 s"), while the paper defines the MI over "the interval where the two curves are significantly separated" (Table 2 legend), which these data give for no HGP MI. The question is for the authors (methods_unavailable, MI window).
  • Not reproduced

    HGP enhancement indicates amygdalar functional integrity (outside the SOZ) with sensitivity 7/7 (100%), specificity 6/7 (86%) and accuracy 13/14 (93%).

    Window (c) gives sensitivity 4/7, 4/7 and 5/7, specificity 3/7, 5/7 and 7/7 and accuracy 7/14, 9/14 and 12/14…

    Results 2.1, paragraph 3; Methods 4.11, paragraph 4rests on an assumptionquestion to the readerhgp-soz-sensitivity-specificity
    From the paper

    With sensitivity (7/7 1⁄4 100% CI [66–100]%), high specificity (6/7 1⁄4 86% CI [42 99]%) and accuracy 93% (13/14, CI [66–99]%), HGP enhancement indicated amygdalar functional integrity

    Reported statistics
    • sensitivity, 7 of 7: 95% CI 66 to 100 %
    • specificity, 6 of 7: 95% CI 42 to 99 %
    • accuracy, 13 of 14: 95% CI 66 to 99 %
    Result

    Window (c) gives sensitivity 4/7, 4/7 and 5/7, specificity 3/7, 5/7 and 7/7 and accuracy 7/14, 9/14 and 12/14 (trial, baseline, amygdala; the trial reading given as measured); no reading gives 7/7, 6/7 and 13/14. The Clopper-Pearson 95% intervals of the paper's counts are 59-100, 42-100 and 66-100%, against the printed 66-100, 42-99 and 66-99%; no single interval method run (one-sided exact, Wilson, Jeffreys) gives all three printed intervals. Asked in questions/000576.yaml.

    Deviations from the paper’s method
    • MI readings as in table2-mi-values; z-scorings as in fig1b-delta-decrease.
    • Assumption. Window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, is the only window reading that defines the MIs this claim needs, so the outcome rests on it. It is taken from the Results' text (Results 2.1, Methods 4.11, "HGP enhancement in the first 2 s"), while the paper defines the MI over "the interval where the two curves are significantly separated" (Table 2 legend), which these data give for no HGP MI. The question is for the authors (methods_unavailable, MI window).
  • Not reproduced

    All 41 neurons fire more during AVERSIVE than during NEUTRAL sequences (FRV 0.26 plus or minus 0.15).

    Over the 24 s blocks and observed epochs 27 of 42 units have FRV > 0, mean 0.033 +- 0.690 Hz (Wilcoxon against…

    Results 2.3, paragraph 2; Figure 3Afig3a-firing-increase-aversive
    From the paper

    All 41 clusters of neurons increased their firing rate during the AVERSIVE condition (Firing Rate Variation, FRV 1⁄4 0.26 �0.15)

    Result

    Over the 24 s blocks and observed epochs 27 of 42 units have FRV > 0, mean 0.033 +- 0.690 Hz (Wilcoxon against 0, p = 0.50); over the 26 s trials, or with all epochs, 23 to 26 positive and means 0.007 to 0.032 Hz. By subject the mean FRV runs from -0.21 to 0.62 Hz. Relative to each unit's mean rate it is 0.061 +- 0.231 (a variant).

    Deviations from the paper’s method
    • Observed epochs as in neuron-count; the variant with all epochs is shown.
  • Not reproduced

    The neurons' firing rose gradually and stayed enhanced throughout the AVERSIVE sequences, not as an immediate response at onset.

    The population AVERSIVE minus NEUTRAL rate (100 ms bins, 1 s smoothing) is 0.310 Hz over 0 to 2 s and 0.018 Hz…

    Results 2.3, paragraph 2; Figure 3Afig3a-firing-gradual-sustained
    From the paper

    Contrary to our expectation of an immediate spiking onset, the neurons increased their firing gradually and sustained enhanced firing throughout the AVERSIVE video sequences

    Result

    The population AVERSIVE minus NEUTRAL rate (100 ms bins, 1 s smoothing) is 0.310 Hz over 0 to 2 s and 0.018 Hz over 2 to 24 s, with its first peak at 0.15 s and 4 of the twelve 2 s bins negative. Neither reading of the criterion holds. It is -0.078 Hz over the baseline clip.

  • Not reproduced

    Across neurons, the spatial synchronization index (SSI) is strongly positively correlated with the firing rate variability (FRV).

    Over the 41 units with another unit in their amygdala, Spearman r between SSI and FRV is 0.26 (p = 0.11) on…

    Results 2.3, paragraph 4; Figure 3C; Figure 4Arests on an assumptionfig3c-ssi-frv-correlation
    From the paper

    We found a strong positive correlation across all participants between the SSI and FRV (Spearman’s r 1⁄4 0.78, p < 1e-7)

    Reported statistics
    • Spearman correlation, r = 0.78, p < 10⁻⁷ (n = neurons with an SSI)
    Result

    Over the 41 units with another unit in their amygdala, Spearman r between SSI and FRV is 0.26 (p = 0.11) on the 1 s time base and 0.40 (p = 0.009) on the 15 s one, against 0.78 with p < 1e-7. Neither reading gives the value, and the 1 s reading misses p < 0.05, so the partial result of the criterion does not hold either. Dropping the 4 pairs likely on one wire gives 0.24 (p = 0.13) and 0.35 (p = 0.023).

    Deviations from the paper’s method
    • SSI uses every other unit of the same amygdala. Methods 4.11 say "on different microwires"; the units table has no microwire column (columns offset, spike_times, obs_intervals, electrodes, electrode_group, waveform_mean, waveform_sd), each unit points only to the bipolar macro channel, and the file holds one electrode group. So the Results' definition, "all neighboring neurons", is assumed. A variant drops pairs likely on one wire by a spike train test (no spikes within 1 ms of each other where the 2 to 12 ms flanks predict at least 3); it flags 4 of 116 testable pairs, and the others fire within 1 ms as often as the flanks predict (median ratio 1.19).
  • Not reproduced

    The per-neuron correlation of firing rate with HGP is described by both FRV and SSI in a multiple linear regression.

    With 15 s time bases for both the firing-HGP r and SSI, R = 0.635 (within 0.059 of 0.59) and model p = 5.6e-5…

    Results 2.4, paragraph 1; Figure 4Bverifier disagreed at firstrests on an assumptionfig4b-regression-firing-hgp
    From the paper

    We found that the co-modulation between neuronal firing and HGP is described by both FVR and SSI (Fig. 4B, r 1⁄4 0.59, p < 1e-4)

    Reported statistics
    • multiple linear regression, r = 0.59, p < 10⁻⁴
    Result

    With 15 s time bases for both the firing-HGP r and SSI, R = 0.635 (within 0.059 of 0.59) and model p = 5.6e-5; over the four readings R = 0.56 to 0.68 and model p from 6e-6 to 7e-4. SSI has p <= 2e-4 in every reading; FRV has p 0.07 to 0.65, with a negative coefficient in three, so the regression is described by SSI alone and the claim's "both FRV and SSI", which the criterion requires, fails in every reading. The SSI variant without likely same-wire pairs gives the same.

    Deviations from the paper’s method
    • SSI as assumed in fig3c-ssi-frv-correlation.

Blocked2

  • Blocked

    In amygdalae outside the SOZ, delta power (1-4 Hz) is lower during AVERSIVE than during NEUTRAL sequences, and the reduction lasts through the AVERSIVE sequence.

    The criterion blocks the claim when the readings disagree, and they do; it holds in 6 of the 12 mixed-model…

    Methods underspecifiedResults 2.1, paragraph 1; Figure 1Bfig1b-delta-decrease
    From the paper

    In nSOZ amygdalae, DELTA band power was consistently reduced throughout the duration of the AVERSIVE sequence (Fig. 1B)

    Reported statistics
    • linear mixed model per time point, cluster-based permutation correction (Fig. 1 legend calls it cluster analysis), p < 0.05
    Result

    The criterion blocks the claim when the readings disagree, and they do; it holds in 6 of the 12 mixed-model readings of the claims file. With the z-score over the whole 26 s trial no reading finds a delta cluster (smallest cluster p 0.88 in all 14 amygdalae, 1.0 in the 7 nSOZ). With z-scoring against the 2 s baseline, AVERSIVE is below NEUTRAL with significant clusters covering 14.3 s of the 24 s block in the nSOZ amygdalae and 15.6 s in all 14. With z-scoring over all trials of the amygdala, 17.1 s in all 14 and none in the nSOZ amygdalae (smallest p 0.072). The block mean of AVERSIVE minus NEUTRAL is negative under every reading (-0.03 to -1.39). The variants agree with the baseline reading (baselinepool 13.3 and 16.8 s, trialsd 7.0 and 16.1 s). The unpaired t-test variant gives the same pattern. The question for the authors is in the findings (methods_unavailable, z-scoring).

    Deviations from the paper’s method
    • The paper's mixed model Power ~ condition + (1|Patients) is computed in its within-patient form (patient fixed effects), which gives the same condition estimate for this balanced design (8 AVERSIVE and 9 NEUTRAL trials per amygdala); the notebook compares it with statsmodels' MixedLM at four time points (t -2.125 against -2.123 and so on).
    • Labels are permuted within each patient, the same permutation for both amygdalae of a patient (Methods 4.11, "permuted the labels of neutral and aversive trials across all participants", 500 permutations); the unpaired t-test variant permutes over all trials.
    • The test is run over the 24 s block (0 to 24 s from onset, Fig. 1 "locked to stimulus onset"); the baseline clip is left out. A choice, stated in the notebook.
    • Outcomes are judged on the three z-scorings of the claims file (trial, baseline, amygdala). Two variants are shown and enter no count of readings, trialsd (the baseline-corrected envelope divided by its SD in the trial) and baselinepool (the epoch's baseline mean and the SD of the baseline clips pooled over the amygdala's epochs, a stable form of baseline z-scoring). The two other baselines of Methods 4.8 (mean of all epochs, previous epoch) are also run as variants.
    • Envelopes are filtered per 26 s epoch with 2 s mirror padding, as the epochs are not contiguous in the files, and kept at 10 Hz after the 1 s smoothing (standard choices).
  • Blocked

    The HGP response is more specific than the DELTA response for indicating amygdalar dysfunction within the SOZ, by a chi-square test that is not significant (p about 0.2).

    The readings disagree on which response is more specific, which the criterion blocks.

    Methods underspecifiedFigure 1F legendverifier disagreed at firstfig1f-hgp-more-specific-than-delta
    From the paper

    The HGP response exceeds the DELTA response in specificity when indicating the amygdala’s dysfunction within SOZ (p~0.2 HGP 5/5 DELTA 1/5, chi2-test)

    Reported statistics
    • chi-square test, p = 0.2 (n = HGP 5/5, DELTA 1/5 (as printed))
    Result

    The readings disagree on which response is more specific, which the criterion blocks. Window (c), the only one that defines the MIs of all 7 SOZ amygdalae, gives HGP more specific under baseline z-scoring (5/7 against 2/7, chi-square p = 0.11) and z-scoring over the amygdala (7/7 against 1/7, p = 0.001), and a tie under z-scoring over the trial (3/7 each). The variants give HGP (6/7 against 1/7 and 3/7). Reading (b), the printed counts 5/5 against 1/5, gives HGP more specific with p = 0.0098 (0.053 with Yates' correction), not about 0.2; no reading gives a p near 0.2.

    Deviations from the paper’s method
    • MI readings as in table2-mi-values; z-scorings as in fig1b-delta-decrease.
    • Assumption. Window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, is the only window reading that defines the MIs this claim needs, so the outcome rests on it. It is taken from the Results' text (Results 2.1, Methods 4.11, "HGP enhancement in the first 2 s"), while the paper defines the MI over "the interval where the two curves are significantly separated" (Table 2 legend), which these data give for no HGP MI. The question is for the authors (methods_unavailable, MI window).

Not tested in a notebook 7

7 data missing from the dataset

Blocked7

  • Blocked

    In the left amygdala of Participant 4, the BOLD time course is negatively correlated with DELTA power and positively correlated with HGP over the video sequence.

    Needs the BOLD time course of the amygdala from the clinical fMRI (Methods 4.6, 4.10).

    Data missing from the datasetResults 2.2, paragraph 2; Figure 2A and 2C; Table 2, amygdala 6uses data from outside the datasetfig2-participant4-bold-correlations
    From the paper

    BOLD response and DELTA power were negatively correlated during presentation of video sequence (correlation of BOLDDELTA time-courses r 1⁄4 �0.48 p < 0.01), while BOLD and HGP were positively correlated (correlation BOLD-HGP Spearman’s r 1⁄4 0.41 p < 0.01)

    Reported statistics
    • BOLD against DELTA: Spearman correlation, r = -0.48, p < 0.01, FDR (Table 2 legend)-corrected
    • BOLD against HGP: Spearman correlation, r = 0.41, p < 0.01, FDR (Table 2 legend)-corrected
    Result

    Needs the BOLD time course of the amygdala from the clinical fMRI (Methods 4.6, 4.10). The paper names no deposit of it; the dandiset holds no fMRI, nor does the iEEG-BIDS version of the same data on OpenNeuro (ds003374, snapshot 1.1.1, which holds only ieeg folders), and the data descriptor lists only iEEG, spikes and electrode positions.

  • Blocked

    Across amygdalae with BOLD, DELTA power and BOLD are negatively correlated in 4 of 5 nSOZ amygdalae, while HGP and BOLD are positively correlated in 3 of 5 nSOZ and 1 of 4 SOZ amygdalae.

    Needs the BOLD time courses, not public (see fig2-participant4-bold-correlations).

    Data missing from the datasetResults 2.2, paragraph 3; Table 2; Figure 2Cuses data from outside the datasettable2-bold-correlations-group
    From the paper

    DELTA power and BOLD responses showed a negative correlation in 4/5 nSOZ amygdalae, while the correlation of HGP and BOLD was positive in the 3/5 the nSOZ amygdalae and 1/4 SOZ amygdalae (Table 2, Fig. 2C)

    Result

    Needs the BOLD time courses, not public (see fig2-participant4-bold-correlations).

  • Blocked

    The Spearman correlations of BOLD with DELTA power and with HGP for each of the 9 amygdalae with BOLD are as printed in Table 2.

    Needs the BOLD time courses, not public (see fig2-participant4-bold-correlations).

    Data missing from the datasetTable 2, columns Correlation BOLD vs. DELTA and BOLD vs. HGP, ruses data from outside the datasettable2-bold-correlation-values
    From the paper

    Not quoted: Values read from Table 2, which no sentence states one by one. Minus signs are garbled in the extracted text (the same glyph as plus or minus); a table cell is read as a minus, and the signs agree with the counts of Results 2.2 (4/5, 3/5, 1/4).

    Result

    Needs the BOLD time courses, not public (see fig2-participant4-bold-correlations).

  • Blocked

    The two nSOZ amygdalae without a significant HGP-BOLD correlation have a very low HGP MI.

    Needs the BOLD-HGP correlations, which need the BOLD time courses, not public (see…

    Data missing from the datasetResults 2.2, paragraph 3; Table 2 (amygdalae 10 and 12)uses data from outside the datasetbold-hgp-uncorrelated-low-mi
    From the paper

    the two nSOZ amygdalae that did not show a significant correlation between HGB and BOLD, had a remarkably low MI for HGP (MI < 0.05, Table 2)

    Result

    Needs the BOLD-HGP correlations, which need the BOLD time courses, not public (see fig2-participant4-bold-correlations).

  • Blocked

    Across neurons, the correlation of firing rate with microwire high gamma power (muHGP) is higher in the AVERSIVE than in the NEUTRAL condition.

    Needs the continuous microwire signals. The dandiset holds only spike times and mean waveforms of the…

    Data missing from the datasetResults 2.3, paragraph 3; Figure 3B, upper boxplotfig3b-firing-muhgp-higher-aversive
    From the paper

    the covariation of neuronal firing with μHGP was higher during AVERSIVE than during NEUTRAL conditions (Spearman’s r 1⁄4 0.51 �0.18 during AVERSIVE, 0.43 �0.16 during NEUTRAL; Wilcoxon paired test, p < 0.01)

    Reported statistics
    • Wilcoxon paired test, p < 0.01 (n = 41 neurons)
    Result

    Needs the continuous microwire signals. The dandiset holds only spike times and mean waveforms of the microwire data, as the data descriptor says was shared; the OpenNeuro version holds macro iEEG only.

  • Blocked

    The per-neuron correlation of firing rate with BOLD is described by FRV but not by SSI.

    Needs the per-neuron correlation of firing with BOLD; the BOLD time courses are not public (see…

    Data missing from the datasetResults 2.4, paragraph 1; Figure 4Cuses data from outside the datasetfig4c-regression-firing-bold
    From the paper

    while the co-modulation between neuronal firing and BOLD is described by FRV (Fig. 4C, Spearman’s r 1⁄4 0.69, p < 1e-4), but not SSI

    Reported statistics
    • multiple linear regression, Spearman's r = 0.69, p < 10⁻⁴
    Result

    Needs the per-neuron correlation of firing with BOLD; the BOLD time courses are not public (see fig2-participant4-bold-correlations).

  • Blocked

    Across neurons, the correlation of firing with HGP is positively correlated with the correlation of firing with BOLD.

    Needs the per-neuron correlation of firing with BOLD; the BOLD time courses are not public (see…

    Data missing from the datasetResults 2.4, paragraph 2; Figure 4Duses data from outside the datasetfig4d-hgp-bold-covariation
    From the paper

    Fig. 4D displays the covariation of neuronal firing with BOLD (x-axis) and HGP (y-axis) (Spearman’s r 1⁄4 0.72, p < 1e-3)

    Reported statistics
    • Spearman correlation, r = 0.72, p < 0.001 (n = neurons, number not given (BOLD exists only for the amygdalae with fMRI))
    Result

    Needs the per-neuron correlation of firing with BOLD; the BOLD time courses are not public (see fig2-participant4-bold-correlations).

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Methods not availableQuestion for the authors. How were the power envelopes "z-scored within each trial" (Methods 4.8), over the whole 26 s trial, against the baseline clip, or otherwise? A z-score over the whole trial makes the baseline correction void and removes the sustained delta decrease, and with it every delta effect here; a z-score against the baseline keeps it. The outcome of fig1b-delta-decrease is blocked on this. Methods 4.8 also says results were quantitatively similar with the mean of all epochs or of the previous epoch as baseline; here the HGP clusters that begin in the first 2 s (nSOZ amygdalae) come only with these baselines, the previous epoch with z-scoring over the amygdala (0.6 to 5.5 s) and, with the trialsd variant, the mean of all epochs (0.6 to 1.9 s) and the previous epoch (0.5 to 8.4 s); the 1 s baseline clip gives none.#
  • Methods not availableQuestion for the authors. Over which window was the modulation index of each amygdala computed? With these data the group test finds no HGP cluster, and per-amygdala tests find clusters in 1 to 3 of 14 amygdalae, while Table 2 prints an MI for every amygdala; the claims on the HGP MI rest on fixed windows (0 to 2 s for HGP, the whole block for delta) taken from the Results' text, an assumption, and the only failing reading of table2-delta-reduced-12-of-14 uses them.#
  • Methods not availableQuestion for the authors. On what time base, and over which span (the condition's blocks laid end to end, or per block), were the per-neuron correlations of firing with HGP in Fig. 3B computed? The test finds no condition difference per block or on the 1 s time base, and finds NEUTRAL higher on the 1.5 s and 15 s time bases over blocks laid end to end.#
  • Paper inconsistentRun on the paper's printed Table 2 values, the tests of Fig. 1E find the DELTA MI also different between nSOZ and SOZ amygdalae (rank-sum p = 0.035, t-test p = 0.013), against "HGP but not DELTA distinguishes"; the chi-square test of the printed counts 5/5 and 1/5 of Fig. 1F gives p = 0.0098 (0.053 with Yates' correction), not about 0.2; and the exact binomial interval for 7/7 is 59-100%, not the printed 66-100%, and no single binomial interval method gives all three printed intervals.#

Questions about the claims 2

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • openasked 2026-10-30about hgp-soz-sensitivity-specificity

    The criterion reads the paper's 95% confidence intervals as two-sided exact (Clopper-Pearson) intervals. For the paper's own counts these are 59-100, 42-100 and 66-100%, against the printed 66-100, 42-99 and 66-99%. Is that the paper's interval, or does the paper use another binomial interval that the criterion should name?

    Passage. With sensitivity (7/7 = 100% CI [66-100]%), high specificity (6/7 = 86% CI [42 99]%) and accuracy 93% (13/14, CI [66-99]%), HGP enhancement indicated amygdalar functional integrity (Results 2.1, paragraph 3); confidence intervals from the binomial distribution (Methods 4.11).

    Why it matters. The verifier of round 1 noted that the printed lower bound for 7/7 matches a one-sided 95% bound (0.05^(1/7), about 65%) and not the two-sided interval of the criterion. No single method run here (two-sided or one-sided Clopper-Pearson, Wilson, Jeffreys) gives all three printed intervals. The intervals are reported, not judged, so no outcome of this attempt changes; a later attempt would report against the right interval.

    No reader has answered it yet.
  • openasked 2026-10-30about fig1e-hgp-not-delta-distinguishes-soz

    Does the claims file name the right tests for Fig. 1E? Run on the paper's own printed Table 2 values, the rank-sum test gives HGP p = 0.004 and DELTA p = 0.035, and the unpaired t-test HGP p = 0.002 and DELTA p = 0.013. Neither gives the legend's p = 0.019 for HGP, and both find DELTA different, against "HGP but not DELTA distinguishes". Is there a reading of the test (another test, a correction, a subset of amygdalae) under which the printed values give the legend's result?

    Passage. HGP but not DELTA distinguishes between amygdalae within SOZ and outside SOZ (p = 0.019, not corrected) (Fig. 1E legend).

    Why it matters. Under the criterion's readings the claim fails on the paper's own values, so the claim as written cannot be reproduced even from Table 2. With these data the HGP MI does not differ under any counted reading (smallest p 0.084), so the outcome here does not change, but a test that matches the printed values could.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction iEEG, neurons and BOLD in the human amygdala during aversive videos (Fedele, Tzovara et al. 2020)

Tests the findings of Fedele, Tzovara et al. (2020) on dandiset 000576, which holds the bipolar amygdala iEEG of 9 patients (14 amygdalae) and the spike times of 42 units from 5 of them during a block design of aversive and neutral videos. It tests the delta and high gamma responses, the modulation indices and their relation to the seizure onset zone, and the firing of the units. The BOLD time courses and the continuous microwire signals are not in the dandiset. All files

Environment: Python 3.13, 29 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-10-30
    Agreed with 20 of 25 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The first executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper. The verifier checked the archive's asset list and metadata for the blocked claims and tested the helper functions on synthetic inputs. It gave its own outcome for each of the 25 claims; 20 agree with the record of that round.
    • nsoz-delta-hgp-mi-inverse: the verifier’s outcome was “Not reproduced”. r<0 in only 3 of 8 readings.
    • table2-delta-reduced-12-of-14: the verifier’s outcome was “Partially reproduced”. 11-13 negative, with negative values both inside and outside the SOZ, under window (a) wherever it is defined and under (c) except trial z-scoring (10). It fails under every per-amygdala window (b) reading (0-2 negative; most MIs are set to 0). The criterion requires every reading.
    • fig1f-hgp-more-specific-than-delta: the verifier’s outcome was “Blocked”. Under the claims file's MI windows, HGP is never more specific: (a) is undefined and (b) gives ties or reverses. Under the notebook's added window (c), HGP is more specific for 3 of 4 z-scorings. The chi-square p (0.001-0.11) never approaches the paper's ~0.2.
    • fig3b-firing-hgp-no-condition-difference: the verifier’s outcome was “Partially reproduced”. No difference at the Fig. 3A time base (both spans, p 0.37/0.83) or with any per-block span. The means are within the stated spreads. With 1.5 s and 15 s concatenated series, NEUTRAL > AVERSIVE at p=0.002 and 0.009.
    • fig4b-regression-firing-hgp: the verifier’s outcome was “Not reproduced”. R is within tolerance in 3 of 4 readings, but the FRV coefficient never reaches p<0.05 (0.07-0.65). The model p<1e-4 in only 2 of 4 readings.
  • Round 2
    2026-10-30
    Agreed with 25 of 25 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook of the first revision, the helper module, the claims file, the attempt record and the README, with the paper. The verifier checked the outcomes, the assumptions and every Result cell, the Summary, the README and the record's notes against the printed outputs, and the round-1 points. It agrees with all 25 outcomes. In reply to its points not tied to one claim, cells 6 and 86 now count five channel locations that do not name the amygdala (not four), cell 86 says the within-patient model gives the same condition estimate as the paper's mixed model (not that it equals it), and the README gives the run time printed by the notebook.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • MI readings as in table2-mi-values; z-scorings as in fig1b-delta-decrease.fig1d-delta-hgp-mi-correlation nsoz-delta-hgp-mi-inverse table2-delta-reduced-12-of-14 table2-hgp-mi-positive-nsoz fig1e-hgp-not-delta-distinguishes-soz hgp-soz-sensitivity-specificity fig1f-hgp-more-specific-than-delta
  • Assumption. Window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, is the only window reading that defines the MIs this claim needs, so the outcome rests on it. It is taken from the Results' text (Results 2.1, Methods 4.11, "HGP enhancement in the first 2 s"), while the paper defines the MI over "the interval where the two curves are significantly separated" (Table 2 legend), which these data give for no HGP MI. The question is for the authors (methods_unavailable, MI window).fig1d-delta-hgp-mi-correlation nsoz-delta-hgp-mi-inverse table2-hgp-mi-positive-nsoz fig1e-hgp-not-delta-distinguishes-soz hgp-soz-sensitivity-specificity fig1f-hgp-more-specific-than-delta
  • Outcomes are judged on the three z-scorings of the claims file (trial, baseline, amygdala). Two variants are shown and enter no count of readings, trialsd (the baseline-corrected envelope divided by its SD in the trial) and baselinepool (the epoch's baseline mean and the SD of the baseline clips pooled over the amygdala's epochs, a stable form of baseline z-scoring). The two other baselines of Methods 4.8 (mean of all epochs, previous epoch) are also run as variants.fig1b-delta-decrease other-bands-no-effect table2-mi-values
  • The paper's mixed model Power ~ condition + (1|Patients) is computed in its within-patient form (patient fixed effects), which gives the same condition estimate for this balanced design (8 AVERSIVE and 9 NEUTRAL trials per amygdala); the notebook compares it with statsmodels' MixedLM at four time points (t -2.125 against -2.123 and so on).fig1b-delta-decrease
  • Labels are permuted within each patient, the same permutation for both amygdalae of a patient (Methods 4.11, "permuted the labels of neutral and aversive trials across all participants", 500 permutations); the unpaired t-test variant permutes over all trials.fig1b-delta-decrease
  • The test is run over the 24 s block (0 to 24 s from onset, Fig. 1 "locked to stimulus onset"); the baseline clip is left out. A choice, stated in the notebook.fig1b-delta-decrease
  • Envelopes are filtered per 26 s epoch with 2 s mirror padding, as the epochs are not contiguous in the files, and kept at 10 Hz after the 1 s smoothing (standard choices).fig1b-delta-decrease
  • As fig1b-delta-decrease. HGP is a 60 Hz high-pass (the claims file's reading); two band-pass variants are shown and do not decide the outcome.fig1c-hgp-increase-first-2s
  • Assumed that the paper's pipeline is one under which its own delta result (Fig. 1B) appears, as the paper reports the delta effect and the absence in other bands from the same analysis (Results 2.1, paragraph 1). The outcome is judged on the readings of the claims file that show the delta effect; the trial reading shows no cluster in any band, delta included. The first revision adopted baseline z-scoring alone; the verifier found that the author's own choice, and it is no longer used.other-bands-no-effect
  • As fig1b-delta-decrease for the test.other-bands-no-effect
  • Window readings (a) group clusters and (b) per-amygdala clusters are the claims file's; (c) fixed windows, 0 to 2 s for HGP and 0 to 24 s for delta, is taken from the Results' text ("occurred at stimulus onset in HGP and was sustained throughout the trial in DELTA", Results 2.1 paragraph 2; "HGP enhancement in the first 2 s or sustained delta decrease", Methods 4.11) and counted as a reading.table2-mi-values
  • Where a window reading finds no significant window for an amygdala, its MI is undefined (the first revision set it to 0); a claim is judged on the readings that define every MI it needs.table2-mi-values
  • Assumption. The only reading that fails uses window (c), fixed windows of 0 to 2 s for HGP and 0 to 24 s for delta, taken from the Results' text (Results 2.1, Methods 4.11) and not from the claims file. The claims file's window readings that define all 14 delta MIs (group clusters under baseline z-scoring in both sets and under z-scoring over the amygdala in all 14) give 11, 11 and 12, all in range. So the outcome rests on counting window (c) as a reading. The question is for the authors (methods_unavailable, MI window).table2-delta-reduced-12-of-14
  • Epochs in which a unit has no spike at all are taken as not recorded (16 units of subject 7 after epoch 11, 4 units of subject 2 in epoch 1), as their rates elsewhere are 1 to 16 Hz.neuron-count
  • Observed epochs as in neuron-count; the variant with all epochs is shown.fig3a-firing-increase-aversive
  • In the readings with the blocks laid end to end, each block is smoothed (or binned) on its own before concatenation, so no sample carries another block or a baseline clip.fig3b-firing-hgp-no-condition-difference
  • HGP is the Methods 4.8 envelope without per-trial normalisation; a per-block Spearman r is unchanged by any per-trial normalisation.fig3b-firing-hgp-no-condition-difference
  • SSI uses every other unit of the same amygdala. Methods 4.11 say "on different microwires"; the units table has no microwire column (columns offset, spike_times, obs_intervals, electrodes, electrode_group, waveform_mean, waveform_sd), each unit points only to the bipolar macro channel, and the file holds one electrode group. So the Results' definition, "all neighboring neurons", is assumed. A variant drops pairs likely on one wire by a spike train test (no spikes within 1 ms of each other where the 2 to 12 ms flanks predict at least 3); it flags 4 of 116 testable pairs, and the others fire within 1 ms as often as the flanks predict (median ratio 1.19).fig3c-ssi-frv-correlation
  • Only the HGP part is tested.fig3d-firing-correlations-modalities
  • SSI as assumed in fig3c-ssi-frv-correlation.fig4b-regression-firing-hgp

Provenance

Attempt record
fedele-2020-01
Paper
The relation between neuronal firing, local field potentials and hemodynamic activity in the human amygdala in response to aversive dynamic visual stimuli
Date
2026-10-30
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:000576 (on DANDI)
Version
0.231010.1811 (doi:10.48324/dandi.000576/0.231010.1811)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-12

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 0 reproduced, 4 partially reproduced, 12 not reproduced, 9 blocked, of 25 claims of Fedele et al. 2020

It counts every claim of the paper in a current attempt, verified or not, as the bar at the top of this page does. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/fedele-2020/"><img src="https://encorescience.org/badge/papers/fedele-2020-outcomes.svg" alt="Encore: 0 reproduced, 4 partially reproduced, 12 not reproduced, 9 blocked, of 25 claims of Fedele et al. 2020"></a>

Or as Markdown:

[![Encore: 0 reproduced, 4 partially reproduced, 12 not reproduced, 9 blocked, of 25 claims of Fedele et al. 2020](https://encorescience.org/badge/papers/fedele-2020-outcomes.svg)](https://encorescience.org/papers/fedele-2020/)

The same numbers are in this page’s JSON, under badge (how it is counted).