The shared method of the claims file takes CLW = CL - CNLW with CNLW fixed at about 4.82 pF. Does the paper compute CLW that way, or per cell with Eq. 8a and Eq. 8c, where CNLW = CSB + root and CSB is the stereocilia bundle capacitance of each cell? For the Fig. S1 cell, CL 24.45 pF and CLW 18.56 pF differ by 5.89 pF, not 4.82 pF, which reads as if 4.82 pF were the root and each cell adds its own CSB (about 1.07 pF for that turn 3 cell). The same question applies to every claim that uses CLW, dVmin_exp or C_Leq (figs1-example-cell, clw-by-turn, fig1-charge-not-linear, fig1-two-state-bounds, fig3a-xe991-fit, fig3a-high-density-deviation, figs4-fine-bins, fig3b-negative-clw-fit, mean-slope-half, fig4a-vh-rises-vd-constant, fig4d-cleq-two-limits, fig4c-sensor-area, fig4e-sensor-charge, table3-pathway-energies, alternative-limit, low-chloride-similar, two-hyperpolarized-states) and to nlw-capacitance, whose 4.82 pF may be the root and not CNLW.
Passage. We determined C N L W by calculating the capacitance of the stereocilia bundle and plotting the maximum measured charge movement ( Q T m ) for each cell as a function of C L - C S B to find the root e x p ( - γ β ) of ... Then C N L W is determined with ... and C L W is then calculated with Eq. 8a (Expressions used to determine the experimental parameters, paragraph 2); and the Fig. S1 legend, C L , 24.45 pF; C L n , 25.94 pF; C L W , 18.56 pF.
Why it matters. With CLW = CL - 4.82 pF, the Eq. 3a fit without XE991 gives Vd 0.0215 V and an unconstrained slope of -0.594, against the paper's 0.034 V and -0.401 (not reproduced). With CLW = CL - 5.89 pF, the value the Fig. S1 legend implies, it gives Vd 0.0322 V and slope -0.372 or -0.405, and all four values of the claim are within tolerance. The adjusted R2 of the Fig. 1 fit (0.585 against 0.538) and the threefold rise of Vh (2.60 against 2.90) move across their tolerances in the same way. The data set stores neither CLW nor CSB, so a per-cell CSB cannot be recovered from it; the claims file would need to say which CNLW, or which rule for CSB, the test uses.
The reader’s answer. The claims file misread the paper, and it is amended. The paper determines CNLW per cell: "We determined C N L W by calculating the capacitance of the stereocilia bundle and plotting ... Q T m ... as a function of C L - C S B to find the root ... Then C N L W is determined with [Eq. 8c] and C L W is then calculated with Eq. 8a". The Fig. S1 legend (CL 24.45 pF, CLW 18.56 pF) shows a CNLW of 5.89 pF for that cell, so the ~4.82 pF of Results paragraph 1 is not a constant applied to every cell. The shared method in the opening comment now takes CLW = CL - CNLW with CNLW = CSB + root per cell, notes that the CSB rule comes from Corbitt et al. (2012) and is not given, and lists readings (L-a) stored per-cell CLW, CNLW or CSB; (L-b) root plus a per-cell CSB rule stated as an assumption, admissible only if it gives the Fig. S1 cell a CLW within tolerance of 18.56 pF; (L-c) a fixed 4.82 pF, shown for comparison only. Claims using CLW, dVmin_exp or C_Leq are judged under (L-a) or else (L-b) and marked as resting on the CSB reading. No statement, expected value or tolerance changed. In nlw-capacitance the expected 4.82 pF stays, as the paper states it as the nonlateral wall capacitance, but its criterion now reads that value as (n-i) the mean per-cell CNLW or (n-ii) the root alone. Which CSB rule to use is a method detail the author takes and states (Author, step 1.6); this answer does not fix one.
The criterion reads the 0.7 um/mV gradient only as a regression slope of length on V0.5 (l-a) or the inverse of the slope of V0.5 on length (l-b). The paper compares it with the mouse gradient of 1.6 um/mV "across the cochlea", which reads as an end-to-end gradient, the difference in mean cell length between the ends of the cochlea (turns 1 and 4 here) over the difference in mean V0.5. Should that reading be added? The paper also gives no source for the 0.7 um/mV, so it may not come from this data set; does the claims file read it as a result of this paper's cells?
Passage. A similar relationship was observed for OHCs extracted from mice, although reported in terms of the length of OHCs, where they found OHCs to exhibit a V 0.5 gradient of 1.6 um/mV across the cochlea ( Zhu et al., 2013 ). The gradient is more than that measured in cells from guinea pigs, at 0.7 um/mV (Results, Experimental magnitude of CLW, QTm, alphaB and V0.5, paragraph 4).
Why it matters. Raised by the round 1 verifier. Regression gives 0.45 to 0.50 um/mV (l-a) and 1.37 to 1.58 um/mV (l-b); the end-to-end reading, run in the notebook as a variant, gives 0.95 to 1.43 um/mV. None is within 0.63 to 0.77, so the reading does not change the outcome in this attempt, but it would decide which value a later attempt compares.
No reader has answered it yet.