What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.
Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.
The claims file reads the population rates in two ways, R1 (all cells of the population, silent ones at 0) and R2 (cells with at least one spike in the last 2.3 s). Does the paper's text also allow a third reading, R3, the cells that fired at least once in the 4.3 s simulation, with rates over the last 2.3 s? If so, should R3 be added to the readings of the rate claims? The same question applies to fig2c-control-it6-rate-activated, control-it5-silenced-activated, control-it4-rate-activated, fig5c-pd-it23-rate-activated, pd-it5-silenced-activated, pd-it6-rate-unchanged, rest-it4-rate-pd-vs-control, rest-it5a-rate-pd-vs-control, activated-it6-rate-pd-vs-control and pt5b-highest-rate.
Passage. Statistically significant change was found for firing rates for excitatory cell types going from rest to activated ... (mean, std dev, range shown; *** p < 0.001; #, truncated maximum rate 73 spikes/s; calculated from the last 2.3 s of 4.3 s simulation to avoid initialization transients). (Fig. 2C legend; also Fig. 5C legend.) The paper does not say which cells enter a population's mean, and the dandiset's units tables hold only the cells that fired at some time in the simulation.
Why it matters. Under R1 and R2 none of the IT claims has its values within tolerance (for example IT2 at control rest, 0.095 and 1.555 spikes/s against 1.2). Under R3 every IT value the claims give is matched to the printed decimal, including the standard deviations (IT2 1.203 +/- 1.649 and 6.662 +/- 8.858 against 1.2 +/- 1.6 and 6.7 +/- 8.9; IT6 5.82, IT5A 3.25, IT5B 3.08, IT4 2.57, parkinsonian IT2 0.783 +/- 1.105 and 4.295 +/- 7.066). For PT5B all 1,435 cells fire, so R1 and R3 coincide and match. Ten claims are not reproduced under R1 and R2, and pt5b-highest-rate is blocked; they would be decided again under R3, whose values and tests are in the notebook as a variant.
The reader’s answer. Changed. The legends say only that rates are "calculated from the last 2.3 s of 4.3 s simulation to avoid initialization transients" (mean, std dev). That fixes the window of the spikes counted. It does not fix the neurons averaged over, and the paper's code (pd_m1_6ohda at 0a1f0e8) holds no rate analysis. Neurons that fired at least once in the 4.3 s simulation, with those silent in the window counted at 0, fit this text as well as R1 and R2 do, and they fit the 0 spikes/s IT5A and IT5B activated rates. NetPyNE 1.0.5 plotSpikeStats, the software the Methods name, gives R2 by default and R1 with includeRate0, but the paper does not say it was used, so this does not rule R3 out. R3 is added to the definitions in the opening comment. Every rate criterion that read "readings R1 and R2" now reads "readings R1, R2 and R3", including the three PT5B rate claims, where R3 changes nothing when every PT5B neuron fires. control-it5-silenced-activated (and so pd-it5-silenced-activated) now uses R1 and R3, and pt5b-highest-rate accepts R1, R2 or R3. Expected values, tolerances and tests are unchanged. This answer was reached from the paper's text. The fit to the data reported in the question played no part in it, and an outcome that holds only under R3 rests on that reading as an assumption.
The criterion takes the share of all PT5B spikes that have a spike of another PT5B neuron within 1 ms (or in the same 1 ms bin), over all 1,435 PT5B cells. Does the paper's text support that measure, or does its 1% to 3% refer to another set of neurons (for example the cells shown in the rasters of Figs. 4 and 7) or another denominator (for example the share of 1 ms bins, or of spikes beyond those expected by chance)? The same question applies to pd-coincident-spikes, and to fig4-control-unitary-events, fig7-pd-unitary-events and rest-synchrony-increase, whose criteria count "2 or more PT5B spikes within 1 ms" over all PT5B cells without saying how a window's coincidences are counted.
Passage. We looked for spikes that fired in the PT5B neuron population within a 1 ms time window of one another and considered those to be coincident spikes. ... PT5B spike coincident firing was observed in 1% of spikes at rest and increased to 3% during the activated state (Fig. 4, cyan lines in A,C cyan + red in raster in B,D). (Results, Control simulations, paragraph 7.) PT5B spike coincident firing (2 or more spikes firing in 1 ms) was observed in 2% of spikes at rest and increased to 3% during the activated state (Fig. 7). (Results, Parkinsonian condition, paragraph 7.) We used unitary event analysis for identifying synchronous spiking significantly above the expected number of synchronous spikes for the neuron population size and firing rates. (Methods, Identifying synchronous spiking.)
Why it matters. Over all 1,435 PT5B cells the population fires 17 to 42 spikes per ms, so 99.95% to 100% of PT5B spikes have another PT5B spike within 1 ms under every reading of the criterion, and two or more cells fire in 99% to 100% of 1 ms bins. No reading over the whole population can give 1% to 3%, so the two coincidence claims fail by construction, and the unitary-event results go from 0 s to 4.0 s of significant synchrony depending on how coincidences are counted (bins, spikes or pairs of cells; notebook). If the paper's measure is over a subset of cells or uses another denominator, the criteria would need to say which, and the outcomes could change.
No reader has answered it yet.
The criteria of the four spectrogram claims define a burst as an epoch where the band's power is above halfway between its minimum and maximum in W, borrowing the half-height convention of the duty cycle, and fig3b takes the 15 Hz bursts in a 14 to 16 Hz band of the reader's choice. The paper defines neither. Should these claims be tested under this convention, or blocked as methods_underspecified? The same applies to fig3b-control-activated-spectrogram, fig6a-pd-rest-spectrogram and fig6b-pd-activated-spectrogram, and, for the duty cycle, to control-duty-cycle and pd-duty-cycle, whose criteria take the unsmoothed 2 ms SCH.
Passage. The rest state simulation revealed virtually continuous power around 2 Hz, as well as 15–25 Hz beta-band bursts (Fig. 3A), occurring every 600 ms (or with a burst-rate of 1.7 Hz). (Results, Control simulations, paragraph 6.) The Methods, Duty cycle, give the half-height convention for the PT5B spike count histogram only, and the Fig. 2 and 5 legends give 2 ms bins; neither says whether the histogram was smoothed.
Why it matters. The four spectrogram claims and the two duty-cycle claims are not reproduced under the criteria's conventions, but those conventions are the reader's, not the paper's. On the unsmoothed 2 ms SCH the half-height is crossed every 10 ms (median period), much shorter than a beta or gamma period, so the duty cycles measure noise crossings. With a half-height burst rule the burst rates come out at 0.9 to 2.6 Hz where the paper reports 1 to 20 Hz. If the claims should be blocked, or tested under another definition, the outcomes change.
No reader has answered it yet.
The criterion says reproduced when the parkinsonian over control ratio of rest LFP power around 15 Hz lies within 3.16 to 31.6 under every reading, and not reproduced when it is below 3.16 under every reading. It gives no outcome for a ratio above 31.6. Should a ratio above 31.6 count as reproduced (at least an order of magnitude), partially reproduced (the increase holds, its size does not) or not reproduced?
Passage. In the resting state, an order of magnitude increase in beta power was observed around 15 Hz. (Discussion, paragraph 3.) Figures 3A and 6A show the increase only through their colour bars (x 10^-5 and x 10^-4).
Why it matters. The ratio is 129 (S1, at 15 Hz), 111 (S1, 14 to 16 Hz) and 65 (S2), above 31.6 under every reading, so the criterion assigns no outcome; the attempt chose partially reproduced, and the round-2 verifier noted that the claims file should close the gap. "An order of magnitude" in the Discussion could mean at least tenfold, in which case the outcome would be reproduced.
No reader has answered it yet.