Rotation with Packet 2 “smeared” the electroporation effect at the perimeter and emphasized the remote effect in the center. This remote effect contrasted with a void of electroporation in the center when the pulse train was applied in the same manner instead of the packet.
Results 3.2, paragraph 2; Figure 5B
Profiles averaged over both diagonals by signed distance, n = 5 and 5. No ROI geometry gives both comparisons under every reading of O1, O2, O4 and O6. In the main geometry the 1P x 40 centre exceeds its lowest value (2.44 to 2.71 mm from the centre) in 24 of 32 readings, every LOESS reading (p = 0.00494 to 0.0327), not with the centre ROI (3581 against 1032 a.u., p = 0.0647 unpaired, 0.114 paired); the 1T x 40 centre is below its most peripheral value (centre 4884 to 5781 a.u. raw and 4570 to 5467 after background, against 10910 to 10989 and 10596 to 10675) in 20 of 32, every unpaired test (p = 0.0145 to 0.0347) and the paired centre-ROI tests (p = 0.0454 and 0.0482), not the paired LOESS tests (p = 0.0582 to 0.0879). Both hold in 12 of 32. With ROIs 3 or 5 steps wide both comparisons hold under all 16 unpaired readings (largest p 0.0329 for 1T x 40 and 0.0148 for 1P x 40), but the paired 1T x 40 test holds in 0 to 10 of 16 (largest p 0.0655 to 0.0904). Both differences go the way the paper says under every reading and geometry. The 1P x 40 centre-ROI mean rests mostly on dish2 (centre 7941 against ends 1575 a.u.; the other four dishes 1827 to 4280); in a full-resolution crop its centre ROI has a mean of 8151 a.u. with no saturated pixel, and pixels above 3 times the crop median cover 44.6% of it in two connected regions, the larger 49 um across (1.4 to 8.2% in the other dishes); by eye these are clusters of round cell-sized spots, consistent with labelled cells, though the measure does not exclude debris. The 1T x 40 centre is the lowest point of its ROI mean profile (4884 a.u.) but not of its LOESS fits; the criterion reports this and does not require it. This outcome reads the criterion as requiring both the paired and the unpaired test of O6 (the criterion cites O6, which runs both for comparisons inside the same dishes, and the fig5a-packet-center-enhanced criterion names both outright). Under the reading in which only the unpaired test counts, the outcome is the same with ROIs one step wide (12 of 16 unpaired readings; the 1P x 40 centre ROI fails, p = 0.0643 to 0.0693 under either ROI end), and both comparisons hold with ROIs 3 or 5 steps wide. ROIs one step wide are the most direct reading of the layout of Methods 2.4 (see fig5c-normalized-contrast), so under that width the outcome does not depend on the reading of O6. A question on the reading of O6 is in questions/000686.yaml.
How the test differed from the paper’s method
- Reading of the criterion. Both the paired and the unpaired test of O6 must hold; see the notes for the outcome under the other reading.
- The positive end of the averaged profile joins the e1 end and the e2 end, e2 taken as the footprint next to e1 clockwise in the image; with rotation every electrode starts the same number of packets, so O2 (b) is read here as the outermost ROI at that joined end (e1 and e2), a labelling choice. It gives the same outcome as O2 (a).
- Trough as in fig5a-packet-center-enhanced (group mean profile, with a leave-one-out variant).
- Profiles measured from the images as in fig5a-trains-stronger (six ROI geometries).