What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.
Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.
The criterion counts, for each region of Extended Data Table 1, the neurons of definition N, which applies the rule of at least 13 neurons per region in a session. The table's neuron column sums to 22,458, the number the Results give for all neurons "localizable to one of 42 brain regions", before any rule of 13 per session. Does the table count every neuron (curated, at least 0.1 Hz) of the 42 regions, the rule of 13 deciding only which regions are among the 42? If so, should the criterion use those neurons?
Passage. "Across all sessions we recorded from 29,134 neurons ... of which 22,458 were localizable to one of 42 brain regions" (Results, Brain-wide recording in visual behavior). "Neurons were only included for further analysis when at least 13 neurons passing the above criteria were identified as coming from the same brain region, in the same experiment. Furthermore, brain regions were only included for which recordings from at least two subjects had sufficient numbers of neurons." (Methods, Data analysis). The claims file notes that the table's neuron column sums to 22,458.
Why it matters. With neurons N, recordings, mice and neurons match in 26 of the 42 regions and the claim is not reproduced. Counting every neuron of the 42 regions, they match in 38 of 42 (recordings exact in 41, mice in 42), and the neurons number 22,434 against 22,458, so the claim would be reproduced. The same reading decides the area lists of supptable2-sessions (38 of 39 sessions match with all neurons, 24 with neurons N).
The reader’s answer. The claims file misread it, and the criterion is changed. The Methods count as a neuron every curated unit with a trial firing rate of at least 0.1 Hz ("Units passing these criteria were considered to reflect the spiking activity of a neuron"); the rule of 13 applies only to "further analysis". The Results give 22,458 "localizable to one of 42 brain regions", the sum of the table's neuron column, and 60.0% of them (13,466) are active, the sum of its responsive column, so the table counts every neuron of the 42 regions. The criterion now counts those neurons, with recordings read as (a) sessions with any neuron of the region or (b) sessions with at least 13, and definition N as a variant. supptable2-sessions now takes its area lists from the same neurons and readings.
The criterion does the PCA "per group and time bin", following jPECC.m. The Methods say the PCA was performed "across time points and trials". Reader step 2 of the protocol puts the Methods before the code where they disagree. Should the criterion use one PCA across time points and trials, with the per-bin PCA of jPECC.m as a variant? The same applies to fig4d-jpecc-no-lag-frontal-midbrain.
Passage. "For each region group, principal components analysis was performed across time points and trials to reduce population activity to 10 dimensions." (Methods, jPECC analysis). jPECC.m calls pca on squeeze(sp1(:,t1,:)) inside the loop over time bins.
Why it matters. The two PCAs can give different canonical correlations at each pair of bins. Here both were run and give the same outcomes (VIS leads Frontal, not Midbrain; one uncorrected significant point for Frontal-Midbrain), so the misreading does not change these outcomes, but a later attempt should follow the Methods.
The reader’s answer. The claims file misread it, and the criterion is changed. The Methods say "For each region group, principal components analysis was performed across time points and trials to reduce population activity to 10 dimensions", one PCA per group, and jPECC.m fits one per time bin. Where they disagree the Methods come first and the code is a variant (Reader, step 2), so fig4d-jpecc-vis-leads now uses one PCA per group across time points and trials, with the per-bin PCA of jPECC.m as a variant. fig4d-jpecc-no-lag-frontal-midbrain takes its method from that claim and follows it with no edit of its own.
The criterion takes the per-region means "as ed6b-prestimulus-order", whose neurons are those of the Figs. 3 to 5 set (task-responsive neurons N). The Fig. 5c and 5d legends average "over all neurons in each region" and give the neurons per region as 130 to 1534, which are the smallest and largest neuron counts of Extended Data Table 1 (PAG and MOs), i.e. every neuron of the region. Should fig5d-go-miss-matches-task-passive, and ed7f-detect-probability-engagement, which takes its task minus passive difference from fig5d, use all neurons of each region, with the Figs. 3 to 5 set as a variant?
Passage. "d, Scatterplot showing difference in pre-stimulus rate between task and passive contexts (x-axis) and between go and miss trials within the task context (y-axis), averaged over all neurons in a region. Text size indicates number of neurons in the analysis (range 130-1534)." (Fig. 5 legend). "c, Brain map showing difference in pre-stimulus firing rate between task and passive conditions, averaged over all neurons in each region." (Fig. 5 legend). Extended Data Table 1 gives 130 neurons for PAG and 1534 for MOs.
Why it matters. The neuron set changes the correlations. With the Figs. 3 to 5 set fig5d gives r = 0.641 (window a) and ed7f gives r = 0.515, both within their criteria; with all neurons N of each region fig5d gives r = 0.494 (p = 0.0009) and ed7f r = 0.444 (p = 0.003, window a) and 0.442 (window b). Both claims are reproduced either way here, but ed7f's tolerance (0.48 ± 0.048, lower bound 0.432) leaves a margin of 0.01 with all neurons, so a later attempt could differ. The verifier of round 1 raised it.
No reader has answered it yet.
The statement is about activation: more neurons are significantly activated by contralateral stimuli on Miss trials than on passive trials. The criterion's expected value is the number of sessions with enough contrast-matched trials (34), with tolerance 0, and the outcome requires exactly 34 sessions to be kept. That number comes from the Methods' description of the matched-contrast selection, not from Fig. 5b. Should the session count be a condition of the outcome, or should the claim be judged on the activation conditions (pooled fraction and the regional excess), with the session count reported?
Passage. "When fewer than 10 such trials could be found, the session was excluded for the matched-contrast analyses (n=34 of 39 sessions included)." (Methods, Training protocol). "More neurons were significantly activated by contralateral visual stimuli on Miss trials than on passive trials" is the claim's statement (Results, Distributed coding of task engagement; Fig. 5b).
Why it matters. Here the selection keeps 36 sessions and no threshold from 10 to 14 gives 34, so the claim is not reproduced on the session count alone. The activation conditions hold: with z-reading Z1 and finite z, the pooled fraction is 4.82% on Miss against 3.24% on passive trials (Figs. 3 to 5 set) and Miss is above passive in 30 of 42 regions. Judged on activation, the claim would be reproduced. The verifier of round 2 raised it.
No reader has answered it yet.