Papers / Saez et al. 2018

Saez et al. 2018 · Current Biology

Encoding of Multiple Reward-Related Computations in Transient and Sustained High-Frequency Activity in Human OFC

Ignacio Sáez, Jack J. Lin, Arjen Stolk, Edward F. Chang, Josef Parvizi, Gerwin Schalk, Robert Thomas Knight, Ming Hsu

Outcomes of 28 claims

  • 10 reproduced
  • 4 partially reproduced
  • 8 not reproduced
  • 6 blocked

Summary: The patients' choice behaviour held up in this data, as did the finding that orbitofrontal high-frequency activity carries the previous round's choices and outcomes but not earlier rounds. The electrode counts behind the encoding results did not: far more electrodes encoded current choice and outcome variables than reported (risk 84 against 50), most likely because the paper does not fully describe its selection rule. The overlap of signal types within electrodes did not match either. Past-trial signals outlasted current ones but were shorter than reported, and several results depend on how the deposited activity was baseline-corrected. The anatomical findings and the comparisons with healthy participants and broadband power could not be tested, as those data are not deposited.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Saez et al. (2018) from CRCNS ofc-3 22 Open in Colab

Reproduced10

  • Reproduced

    Patients were approximately risk neutral, choosing the gamble only slightly more often than a risk-neutral baseline model, on 55.9% (plus or minus 8.5%) of trials.

    The gamble was chosen on 54.9% of non-timeout rounds averaged over patients (SD 8.6, reading (a)) and 55.1%…

    Results, Economic Choice Behavior in Neurosurgical Patients, paragraph 4behavior-risk-neutral
    From the paper

    we found that subjects were approximately risk neutral, choosing to gamble only slightly more often than a risk neutral baseline model (55.9% ± 8.5% of risky choices)

    Result

    The gamble was chosen on 54.9% of non-timeout rounds averaged over patients (SD 8.6, reading (a)) and 55.1% pooled (reading (b)), both within 55.9 plus or minus 8.5. Per patient the share runs from 46.8 to 73.5%. A risk-neutral chooser (gamble when win probability times prize exceeds $10, ties split) would gamble on 53.0%, so patients gamble slightly more often, as the statement says.

  • Reproduced

    The proportion of risky choices increased with win probability, well captured by a logit model (p < 0.001, random effects logit analysis).

    Random-effects logit of gamble choice on win probability over 1,839 non-timeout rounds.

    Results, Economic Choice Behavior in Neurosurgical Patients, paragraph 4; Figure 1Cfig1c-choice-win-probability
    From the paper

    The proportion of risky choices increased as the offer value (win probability) increased, which was well captured by a logit model of decision under risk (p < 0.001; random effects logit analysis; Figure 1C)

    Reported statistics
    • random effects logit analysis, p < 0.001 (n = 10 patients)
    Result

    Random-effects logit of gamble choice on win probability over 1,839 non-timeout rounds. Slope 4.79 (SE 0.24, p = 1.5e-86) with a random intercept, 5.75 (SE 0.33, p = 6.0e-70) with a random intercept and slope. The share of gamble choices rises from 15 to 17% at win probabilities 0 to 0.1 to 76 to 82% at 0.6 to 1. Per patient the slope is significant and positive in 8 of 10; s04 and s10 show no significant effect.

    Deviations from the paper’s method
    • The random-effects logit is fitted by maximum likelihood with Gauss-Hermite quadrature (20 points, or 12 by 12 with a random slope) in the helper, with Wald tests from a numerical Hessian; the paper used R and does not name the routine. A standard choice.
  • Reproduced

    Patients' choices were sensitive to the expected value of the gamble (prize times win probability), with gamble choices more frequent at higher gamble expected value.

    Gamble choices rise from 16.9% at an expected value of $0 to 68 to 87% above $15.

    Figure S2A legendfigs2a-choice-gamble-ev
    From the paper

    Patients' choices were sensitive to the expected value of the gamble (i.e., the gamble prize times the win probability), with gamble choices more prevalent for higher gamble expected value

    Result

    Gamble choices rise from 16.9% at an expected value of $0 to 68 to 87% above $15. The logit slope on expected value is 0.163 per $ (p = 2e-69) with a random intercept and 0.161 (p = 4e-45) with a random slope as well.

  • Reproduced

    Regressors were weakly correlated between and within categories (mean R2 0.15, all R2 below 0.6).

    For the 8 current regressors (reading (a)), the mean R2 over 28 pairs is 0.155 on pooled trials and 0.165…

    From the paper

    Regressors were weakly correlated between and within categories (mean R2=0.15, all R2<0.6)

    Result

    For the 8 current regressors (reading (a)), the mean R2 over 28 pairs is 0.155 on pooled trials and 0.165 averaged over patients, both within 0.15 plus or minus 0.015; the largest pair is loss index with RPE (0.55 pooled, 0.57 averaged), below 0.6. With the 8 t-1 regressors added (reading (b), 120 pairs) the mean is 0.072 pooled and 0.079 averaged.

  • Reproduced

    The delays of choice encoding after game presentation and of outcome encoding after outcome reveal did not differ (512.5 plus or minus 59 ms against 287 plus or minus 114.33 ms, p = 0.14, t test), nor did their transient durations (612.15 plus or minus 132.9 ms against 712.5 plus or minus 112.5 ms, p = 0.58).

    With the outcome reveal at time 0 of the buttonpress epoch, the choice and outcome delays do not differ under…

    Results, OFC HFA Reflects Choice- and Outcome-Related Valuation Signals, paragraph 3rests on an assumptionquestion to the readerfig3-latency-duration-similar
    From the paper

    The delays after the presentation of external information, game presentation and outcome reveal, respectively, were not statistically different (512.5 ± 59 ms and 287 ± 114.33 ms; p = 0.14; t test), with transient activation profiles of comparable duration (612.15 ± 132.9 ms and 712.5 ± 112.5 ms, respectively; p = 0.58; t test)

    Reported statistics
    • delay, choice against outcome: t test, p = 0.14
    • duration, choice against outcome: t test, p = 0.58
    Result

    With the outcome reveal at time 0 of the buttonpress epoch, the choice and outcome delays do not differ under reading (a) (peak of the mean %EV, 800 plus or minus 74 against 650 plus or minus 87 ms, p = 0.235) or reading (b) (first window above the shuffled share, 512.5 plus or minus 101 against 325 plus or minus 132 ms, p = 0.301), and the durations do not differ (687.5 plus or minus 155 against 1,000 plus or minus 158 ms, p = 0.207). Under reading (b) both delays are within the paper's values, the choice duration is within 612.15 plus or minus 132.9 ms and the outcome duration is not. With the reveal 550 ms after time 0 (the claims file's description of the epoch) the delays differ (p < 0.001 under (a), 0.006 under (b)). Under the per-electrode reading (c), less supported by the claims file, the delays differ (p = 0.026) and the durations do not (p = 0.462). Under the claims file's baseline readings (a) and (b), reading (a) of the delays gives p = 0.224 and 0.200 and the durations p = 0.118 and 1.000; reading (b) of the delays gives p = 0.034 under baseline (a) and 0.052 under baseline (b). The outcome holds under all three baselines, as reading (a) holds under each and one reading suffices.

    Deviations from the paper’s method
    • The outcome rests on the reading of the buttonpress epoch as locked to the outcome reveal. The data description says the epoch is centred on the button press; the data show it is centred 470 to 600 ms after the csv's button press and that the gamble outcome is encoded from about 200 ms after its time 0, which fits a reveal-locked epoch, and the paper's Figure 3C labels the epoch "time locked to gamble outcome (t = 0)". The true event times are not in the files.
    • Delay and duration are measured on windows that start at or after the event; the chance profile is the mean %EV of the electrodes selected under the 1,000 shuffles, and the chance share for reading (b) the 95th percentile of the shuffled share per window. Standard choices, as the paper does not define them.
    • The HFA is used as deposited; the claims file's baseline readings, shown in the notebook, give the same outcome.
  • Reproduced

    Encoding of past information was limited to the immediately preceding trial; the proportion of electrodes encoding choices and outcomes 2 to 5 trials back was significantly lower than for the current and previous trials (p < 0.01, t test), with no evidence of encoding from earlier rounds.

    Mean proportions of encoding electrodes over the 8 regressors are 31.8% (t), 34.9% (t-1) and 16.6, 17.7, 16.9…

    Results, Dissociable OFC Encoding of Past Choice and Outcome Information, paragraph 3; Figure 6A and 6Bquestion to the readerfig6-past-short-lived
    From the paper

    Strikingly, we found no evidence for encoding of information from earlier rounds

    Reported statistics
    • t test, p < 0.01
    Result

    Mean proportions of encoding electrodes over the 8 regressors are 31.8% (t), 34.9% (t-1) and 16.6, 17.7, 16.9 and 19.4% (t-2 to t-5). Reading (a), per-regressor proportions at t-2 to t-5 against t, p = 2.9e-10, and against t-1, p = 7.6e-11; reading (b), the lag means against t, p = 1.9e-04, and against t-1, p = 1.1e-04. No lag from t-2 to t-5 exceeds the 95th percentile of the chance proportion (20.5 to 20.7%, chance mean 18.2 to 18.3%). Only loss index at t-3 exceeds its own 95th percentile. Under the claims file's baseline readings (a) and (b) the outcome is the same (t-2 to t-5 against t and t-1, p from 3.3e-09 to 1.1e-03 under reading (a); no lag above the chance 95th percentile).

    Deviations from the paper’s method
    • Lags t-2 to t-5 are built from the rounds, as the data set's regressor file holds t-1 only.
  • Reproduced

    The distribution of encoding significance at the peak %EV shows a sharp boundary between t-1 and t-2 but not between t and t-1 (one-sided Kolmogorov-Smirnov tests).

    One-sided KS tests on -log10 p at each electrode's peak %EV window (both epochs). t-2 lies above t-1 with p <…

    Figure S5C and S5D legendsrests on an assumptionfigs5d-sharp-boundary
    From the paper

    Summary statistical results for ECDFs in (C) highlighting the sharp temporal boundary in encoding extent between t-1 and t-2, but not t and t-1

    Result

    One-sided KS tests on -log10 p at each electrode's peak %EV window (both epochs). t-2 lies above t-1 with p < 0.05 for all 8 regressors (p at most 0.022; pooled D = 0.207, p = 2.6e-29). t-1 lies above t for risk only (p = 0.0002); for the other 7 p = 0.18 to 1 (pooled p = 0.968). 7 of 8 regressors and the pooled test show the boundary between t-1 and t-2 and not between t and t-1. Under the claims file's baseline readings (a) and (b), the pooled t-1 against t test is also significant (p = 3e-05 and 0.0014) and 3 and 4 of 8 regressors show the pattern, so the outcome rests on the deposited baseline (assumed).

    Deviations from the paper’s method
    • The HFA is used as deposited, as the authors' own baseline correction (an assumption): the game epoch is corrected over [-1000, -800] ms (its first window is the same in every trial) and the buttonpress epoch carries a per-trial offset close to it. STAR Methods say only that epochs were made "using a 200-ms baseline to remove any pre-stimulus differences in baseline amplitude", and the data description that "activity for both epochs is temporally aligned". The claims file's readings, (a) the 200 ms before each epoch's event and (b) the 200 ms before game presentation for both epochs (the buttonpress epoch first put on the game epoch's level with its per-trial, per-electrode offset, measured where the epochs overlap), are applied on top of it in the notebook's section Baseline readings.
  • Reproduced

    In nested mixed-effects models with patient and electrode as random effects, all regressors were significant (all p < 10^-4, Bonferroni corrected).

    All models have patient and electrode within patient as random intercepts (REML), fitted by a closed form in…

    Results, Dissociable OFC Encoding of Past Choice and Outcome Information, paragraph 4; STAR Methods, Stepwise regression, paragraph 3verifier disagreed at firstrests on an assumptionmixed-effects-robust
    From the paper

    We found that all of our regressors were significantly active

    Reported statistics
    • nested mixed-effects model, p < 10⁻⁴, Bonferroni-corrected
    Result

    All models have patient and electrode within patient as random intercepts (REML), fitted by a closed form in the helper that agrees with statsmodels MixedLM on three fits (slopes and SEs to four or more significant digits, p within 2%). Every combination of the claims file's readings was run. Time point (a), one model per window, Bonferroni over 16 regressors and 114 windows (the game epoch's constant baseline window is skipped): one regressor and all electrodes 14 of 16 reach corrected p < 10^-4, past chosen value (1.7e-03) and past risk (3.0e-03) do not; one regressor and encoding electrodes 11 of 16; all regressors together 11 (all electrodes) and 11 (encoding electrodes) of the 14 that can be estimated, as gamble is the sum of the win and loss indices at t and t-1. Time point (b), HFA averaged over post-event windows, Bonferroni over 16 regressors and 2 epochs: 4, 6, 3 and 3. Under the claims file's baseline reading (a), the per-window model with one regressor and all electrodes makes all 16 significant (largest corrected p 3.3e-05, past gamble), and under (b) 15 (past risk 2.9e-02). The outcome is reproduced, as the criterion passes under one reading; it rests on baseline reading (a) and the per-window reading of the time point (assumed), and is the best of the 24 combinations of readings run. Set after the verifier agreed in round 3. Signed slopes average over electrodes encoding in opposite directions.

    Deviations from the paper’s method
    • The HFA is used as deposited, as the authors' own baseline correction (an assumption): the game epoch is corrected over [-1000, -800] ms (its first window is the same in every trial) and the buttonpress epoch carries a per-trial offset close to it. STAR Methods say only that epochs were made "using a 200-ms baseline to remove any pre-stimulus differences in baseline amplitude", and the data description that "activity for both epochs is temporally aligned". The claims file's readings, (a) the 200 ms before each epoch's event and (b) the 200 ms before game presentation for both epochs (the buttonpress epoch first put on the game epoch's level with its per-trial, per-electrode offset, measured where the epochs overlap), are applied on top of it in the notebook's section Baseline readings. The outcome rests on baseline reading (a), which the claims file names, with one model per window (assumed).
    • The nested model is fitted by REML in closed form (helper nested_lmm), which uses the fact that every electrode of a patient shares its trials and regressors; it is checked against statsmodels MixedLM in the notebook. A standard choice.
    • Time point (b) fits each epoch and counts a regressor when significant in either, with the correction over 16 regressors and 2 epochs. The joint model leaves out the two gamble regressors, which are the sums of the win and loss indices and cannot be estimated with them.
  • Reproduced

    The direction of the response (left or right option) is not reflected in OFC HFA.

    31 electrodes (16.2%) meet the encoding rule for the response side (left = 1), below the shuffled mean (34.7)…

    Figure S3B legend; Results, OFC HFA Reflects Choice- and Outcome-Related Valuation Signals, paragraph 3; Discussion, paragraph beginning "Finally, although ECoG is not affected"question to the readerfigs3b-no-motor-encoding
    From the paper

    Regressors encoding direction of choice (left/right options) are not reflected in OFC HFA

    Result

    31 electrodes (16.2%) meet the encoding rule for the response side (left = 1), below the shuffled mean (34.7) and the 95th percentile (49); the count is at the 34.5th percentile of the shuffles. The peak mean %EV is 1.61 (game epoch) and 2.00 (buttonpress epoch, at -550 ms), against chance profiles up to 1.25 and 1.26. Under the claims file's baseline readings the count is 35 and 28, below the 95th percentiles 55 and 47.

    Deviations from the paper’s method
    • The response side is the csv's choice.location.
  • Reproduced

    Example electrodes show risk encoding with an inverted U relation between win probability and HFA at peak encoding, and regret encoding with a linear drop of HFA with regret.

    Of 84 risk-encoding electrodes, 44 have a significant negative quadratic term in win probability at their peak…

    Figure 2D to 2G legendsfig2-example-electrodes
    From the paper

    The relationship follows an inverted u shape with win probabilities as would be expected for risk encoding

    Result

    Of 84 risk-encoding electrodes, 44 have a significant negative quadratic term in win probability at their peak %EV window (an inverted U) and 40 a significant positive one. All 64 regret-encoding electrodes have a significant linear slope on regret at their peak window, 38 with HFA rising with regret (falling as regret becomes more negative) and 26 the other way. The regret half holds by construction, as an electrode selected for encoding regret has a significant slope at its peak window. Under the claims file's baseline readings 32 of 75 and 18 of 66 risk electrodes show an inverted U and all regret electrodes a slope.

Partially reproduced4

  • Partially reproduced

    Of 210 OFC electrodes recorded in 10 patients, 192 were artifact-free and included; each patient played 200 rounds, and timeouts, 9.98% of all trials, were excluded.

    The data set holds 10 patients. It holds 199 electrode columns; seven in s03 (52 to 58) are exact copies of…

    STAR Methods, ECoG Recording, and Behavioral task; Table S2, last rowmethods-electrode-trial-counts
    From the paper

    Out of 210 OFC electrodes, 192 were artifact-free and included in subsequent analyses

    Result

    The data set holds 10 patients. It holds 199 electrode columns; seven in s03 (52 to 58) are exact copies of electrodes 45 to 51 in both the 1-kHz and the window arrays, and without them the per-patient counts are 5, 6, 52, 5, 61, 7, 11, 10, 19 and 16, those of Table S2, 192 in all. One of these, s03 electrode 42, holds no data of its own (its 1-kHz trace copies electrode 34 and its windows copy electrode 41), so 191 unique recordings are analysed. Timeouts are 99 of 1,938 rounds, 5.11% (4.95% of 2,000), outside 9.98 plus or minus 0.998, and s10 has 138 rounds, not 200. The share of rounds that have no HFA trial (timeouts and other exclusions), 185 of 1,938 or 9.55%, would fall inside the tolerance; it is shown as a variant, as the claims file defines the percentage on timeout trials. The HFA trials are matched to rounds in order; matching them in reverse gives the same rounds except one s02 trial, where only the forward match agrees with the authors' t-1 values, so the match is unique and no matched round is a timeout.

    Deviations from the paper’s method
    • The electrode count of 192 is the deposited count with the seven copied electrodes of s03 removed; the analysis itself uses 191, counting each recording once.
  • Partially reproduced

    HFA encodes characteristics of the preceding trial; past choice and outcome features are widely represented across OFC except past risk, dissociable from current signals.

    Encoding electrodes for the t-1 regressors are 40 risk, 64 gamble, 59 win probability, 53 chosen value, 67…

    Results, Dissociable OFC Encoding of Past Choice and Outcome Information, paragraphs 1 and 2; Figure 4A to 4D; Table S2rests on an assumptionquestion to the readerfig4-past-encoding
    From the paper

    features were widely represented across the OFC, with the exception of past risk, and were dissociable from current choice and outcome signals

    Result

    Encoding electrodes for the t-1 regressors are 40 risk, 64 gamble, 59 win probability, 53 chosen value, 67 win, 79 loss, 76 RPE and 95 regret. The seven other than risk exceed the 95th percentile of their shuffles (48 to 50) and past risk has the lowest count, below its 95th percentile (49). None of the eight counts is within 10% of Table S2 (17, 43, 46, 35, 49, 56, 50, 64). The mean %EV of the t-1 regressors is above chance in 56 of 57 game-epoch windows and all 57 buttonpress-epoch windows. The own-null variant of fig3-present-encoding gives 9, 33, 27, 22, 35, 37, 28 and 40. Under the claims file's baseline readings (a) and (b), only 2 and 1 of the seven past regressors other than risk exceed their shuffles, and under (b) past risk is not the lowest, so the outcome rests on the deposited baseline (assumed).

    Deviations from the paper’s method
    • The HFA is used as deposited, as the authors' own baseline correction (an assumption): the game epoch is corrected over [-1000, -800] ms (its first window is the same in every trial) and the buttonpress epoch carries a per-trial offset close to it. STAR Methods say only that epochs were made "using a 200-ms baseline to remove any pre-stimulus differences in baseline amplitude", and the data description that "activity for both epochs is temporally aligned". The claims file's readings, (a) the 200 ms before each epoch's event and (b) the 200 ms before game presentation for both epochs (the buttonpress epoch first put on the game epoch's level with its per-trial, per-electrode offset, measured where the epochs overlap), are applied on top of it in the notebook's section Baseline readings.
    • The t-1 regressors are the authors' file values, which keep rounds after a timeout with 0 for the choice and outcome regressors. The analysis uses 191 electrodes.
  • Partially reproduced

    Past-trial signals were sustained; the longest continuous stretch of significant encoding was longer for past outcome (1,341.37 plus or minus 49.63 ms) and past choice (1,169.15 plus or minus 61.2 ms) than for current choice (799.6 plus or minus 36.94 ms) and current outcome (706.9 plus or minus 30.56 ms), all p < 10^-6, t test.

    Under epoch reading (a) and stretch reading (a), mean durations are 669.9 (past outcome, n = 317), 650.7 (past…

    Results, Dissociable OFC Encoding of Past Choice and Outcome Information, paragraph 2; Figure 5A and 5Brests on an assumptionfig5-past-sustained
    From the paper

    both past outcome (average duration = 1,341.37 ± 49.63 ms) and past choice (1,169.15 ± 61.2 ms) showed significantly more sustained activation than current choice and outcome signals (799.6 ± 36.94 and 706.9 ± 30.56 ms, respectively; all

    Reported statistics
    • each past group against each current group: t test, p < 10⁻⁶ (n = electrode and regressor pairs with encoding, per group)
    Result

    Under epoch reading (a) and stretch reading (a), mean durations are 669.9 (past outcome, n = 317), 650.7 (past choice, 216), 534.2 (choice, 257) and 462.0 ms (outcome, 229); adding the 150 ms of the window (readings (b) and (c), which coincide) gives 819.9, 800.7, 684.2 and 612.0 ms. Both past groups are longer than both current groups with p from 8.0e-07 to 8.8e-03, all below 0.01, but only past outcome against current outcome is below 10^-6. Under epoch reading (b) past choice against current choice gives p = 0.011. No mean is within the stated SEM or 10% of the paper's values under any reading; the past durations are 368 to 720 ms shorter than the paper's, depending on the reading (368 to 671 ms under epoch reading (a)). Under the claims file's baseline readings (a) and (b), none of the four comparisons reaches p < 0.01 under epoch reading (a) (p from 0.022 to 0.73), nor under epoch reading (b), so the outcome rests on the deposited baseline (assumed).

    Deviations from the paper’s method
    • The HFA is used as deposited, as the authors' own baseline correction (an assumption): the game epoch is corrected over [-1000, -800] ms (its first window is the same in every trial) and the buttonpress epoch carries a per-trial offset close to it. STAR Methods say only that epochs were made "using a 200-ms baseline to remove any pre-stimulus differences in baseline amplitude", and the data description that "activity for both epochs is temporally aligned". The claims file's readings, (a) the 200 ms before each epoch's event and (b) the 200 ms before game presentation for both epochs (the buttonpress epoch first put on the game epoch's level with its per-trial, per-electrode offset, measured where the epochs overlap), are applied on top of it in the notebook's section Baseline readings.
  • Partially reproduced

    Stepwise regression with model selection gave proportions of encoding electrodes per regressor similar to those of the 5-consecutive-window selection.

    After the permutation step (10,000 shuffles, Bonferroni over 191 electrodes) and forward selection, 16 of 191…

    Results, Dissociable OFC Encoding of Past Choice and Outcome Information, paragraph 4; Figure S6Brests on an assumptionfigs6b-stepwise-similar
    From the paper

    The proportion of electrodes encoding each reward-related computational component as estimated by selecting electrodes with ≥5 consecutive encoding windows and stepwise regression followed by model selection were similar

    Result

    After the permutation step (10,000 shuffles, Bonferroni over 191 electrodes) and forward selection, 16 of 191 electrodes keep any regressor; the stepwise proportions are 0 to 2.1% against 20.9 to 49.7% for the 5-window selection. The two are ranked alike (Spearman rho 0.77, p < 0.001, reading (a) holds) but differ by up to 48.2 points (reading (b) fails). The permutation step alone gives 0 to 2.6% (rho 0.65, p = 0.006). On a synthetic electrode the procedure gives p = 0.0005, the smallest possible with 2,000 shuffles. Reading (a) passes only formally, as the stepwise proportions are 0 for 9 of 16 regressors; in substance the two selections are not similar. Under the claims file's baseline readings (a) and (b), stepwise keeps 5 and 4 electrodes, Spearman rho is 0.43 (p = 0.101) and -0.25 (p = 0.349), and the largest difference 42.9 and 38.7 points, so neither reading holds; the outcome also rests on the deposited baseline.

    Deviations from the paper’s method
    • The HFA is used as deposited, as the authors' own baseline correction (an assumption): the game epoch is corrected over [-1000, -800] ms (its first window is the same in every trial) and the buttonpress epoch carries a per-trial offset close to it. STAR Methods say only that epochs were made "using a 200-ms baseline to remove any pre-stimulus differences in baseline amplitude", and the data description that "activity for both epochs is temporally aligned". The claims file's readings, (a) the 200 ms before each epoch's event and (b) the 200 ms before game presentation for both epochs (the buttonpress epoch first put on the game epoch's level with its per-trial, per-electrode offset, measured where the epochs overlap), are applied on top of it in the notebook's section Baseline readings.
    • Assumed, as STAR Methods do not say, that the longest significant stretch is taken in each epoch and the larger sum of F used, and that the model comparison (ANOVA) is made on the HFA of the window where the base regressor has its peak %EV. Other readings (a stretch across both epochs, comparisons at each regressor's own peak) were not run; the permutation step, which leaves only 16 electrodes, does not depend on the second choice.
    • The Bonferroni correction uses the 191 electrodes analysed; the paper says 192.

Not reproduced8

  • Not reproduced

    Reaction times were longer in high-conflict trials (win probability 40 to 60%) than in low-conflict trials (below 30% or above 70%), in patients and in healthy subjects (both p < 0.001, t test), with comparable effect sizes.

    RT is buttonpress.time minus choice.time (game presentation).

    Figure S2B legendfigs2b-rt-conflict
    From the paper

    Patients and healthy subjects took longer to react in high-conflict trials (both p<0.001, t-test), and the effect size was comparable between both groups

    Reported statistics
    • patients, high against low conflict: t test, p < 0.001
    • healthy subjects, high against low conflict: t test, p < 0.001
    Result

    RT is buttonpress.time minus choice.time (game presentation). High-conflict RTs are longer on average (1.691 against 1.476 s over pooled trials, Cohen's d 0.07; 179 ms per patient, d_z 0.57), but p = 0.165 for the pooled two-sample test (reading (a)) and p = 0.104 for the paired test over 10 patients (reading (b)), neither below 0.001. s10's reaction times are not bounded by the 2-s limit (median 4.4 s, up to 80.5 s) and dominate the pooled test; without s10 the pooled test gives p = 2.2e-06 and the paired test p = 0.147 (variant). Per patient the difference runs from -200 to 932 ms. The healthy subjects' part and the comparison of effect sizes cannot be tested (no data). Leaving s10 out is not a reading the claims file allows; it is shown for sensitivity only.

    Deviations from the paper’s method
    • Game presentation is taken as the csv column choice.time, which the data description does not list; it is 0.66 to 0.97 s after trial start, near the paper's 750 ms.
    • RT is taken as buttonpress.time minus choice.time, an inference from the data; the description does not define these columns.
  • Not reproduced

    Past and current regressors were nearly uncorrelated (mean R2 2.1%, maximum R2 3.7%).

    The regressors are the authors' own (sXX_behav_globals.mat) over the HFA trials, with t-2 to t-5 built by the…

    Results, Dissociable OFC Encoding of Past Choice and Outcome Information, paragraph 1regressors-past-current-uncorrelated
    From the paper

    past and current regressors were uncorrelated (mean R2 = 2.1%; max R2 = 3.7%)

    Result

    The regressors are the authors' own (sXX_behav_globals.mat) over the HFA trials, with t-2 to t-5 built by the same convention. Mean and maximum R2, averaged over patients and on pooled trials, are (a) own t-1 pairs 0.37 and 0.70% averaged, 0.25 and 0.64% pooled; (b) all current by t-1 pairs 0.53 and 1.73%, 0.23 and 1.20%; (c) all current by t-1 to t-5 pairs 0.59 and 2.29%, 0.21 and 1.71%. None is within 2.1 plus or minus 0.21% and 3.7 plus or minus 0.37%. Past and current regressors are uncorrelated, more so than the paper reports. Over the 1,839 non-timeout rounds the criterion names (variant, regressors built from the rounds), the mean R2 is 0.21 to 0.56% and the maximum 0.64 to 1.87% across readings, also outside the tolerance.

  • Not reproduced

    OFC HFA encodes the choice regressors (risk, gamble choice, offer value, chosen value), time locked to game presentation, and the outcome regressors (gamble win, gamble loss, RPE, regret), time locked to outcome reveal, with average %EV above chance and a rise in the number of encoding electrodes.

    Encoding electrodes (p < 0.05 in 5 or more consecutive windows of either epoch) over 191 electrodes are 84…

    Results, OFC HFA Reflects Choice- and Outcome-Related Valuation Signals, paragraphs 2 and 3; Figure 3A to 3D; Table S2question to the readerfig3-present-encoding
    From the paper

    we found robust evidence within the HFA band for multiple valuation components related to choice (risk, gamble choice, offer value, and expected value of chosen option ... and outcome (gamble win, gamble loss, RPE, and regret) processing

    Result

    Encoding electrodes (p < 0.05 in 5 or more consecutive windows of either epoch) over 191 electrodes are 84 risk, 71 gamble, 61 offer value, 41 chosen value, 59 win, 54 loss, 52 RPE and 64 regret, none within 10% of Table S2 (50, 34, 31, 26, 45, 33, 28, 35). The 95th percentile of the shuffled counts is 48 to 50; chosen value (41) does not exceed it, the other seven do. The timing holds; the mean %EV of the choice regressors peaks 750 ms after game presentation, that of the outcome regressors 800 ms after time 0 of the buttonpress epoch (250 ms after a reveal at +550 ms, the claims file's timing), and the per-window share of electrodes at p < 0.05 peaks at 850 ms for both under reading (b) (850 and 650 ms under reading (a)). The selection classifies 18.2% of electrodes as encoding under shuffled labels, on average about 35, more than Table S2 reports for chosen value, which suggests the paper's selection differs in a detail it does not state (finding). A variant that also requires an electrode's longest run to exceed the 95th percentile of its own shuffled runs gives 41, 31, 21, 12, 24, 15, 15 and 17, all below Table S2. Per patient most encoding electrodes are in s03 and s05, as in Table S2. Under the claims file's baseline readings (a) and (b) the counts are 75, 82, 54, 51, 74, 51, 64, 63 and 66, 74, 56, 37, 68, 41, 50, 45, none within 10%, and chosen value stays below the 95th percentile of its shuffles (51 against 55, 37 against 47), so the outcome is the same under all three.

    Deviations from the paper’s method
    • The HFA is used as deposited, as the authors' own baseline correction (an assumption): the game epoch is corrected over [-1000, -800] ms (its first window is the same in every trial) and the buttonpress epoch carries a per-trial offset close to it. STAR Methods say only that epochs were made "using a 200-ms baseline to remove any pre-stimulus differences in baseline amplitude", and the data description that "activity for both epochs is temporally aligned". The claims file's readings, (a) the 200 ms before each epoch's event and (b) the 200 ms before game presentation for both epochs (the buttonpress epoch first put on the game epoch's level with its per-trial, per-electrode offset, measured where the epochs overlap), are applied on top of it in the notebook's section Baseline readings.
    • The analysis uses 191 electrodes (the paper 192); s03 electrode 42 holds no data of its own.
    • The buttonpress epoch's time 0 is read as the outcome reveal, as the data indicate; the claims file's timing (reveal 550 ms after time 0) is shown alongside, and the timing condition holds under both.
  • Not reproduced

    None of the past trial characteristics significantly affected risk taking (all p > 0.15, random effects logistic regression).

    Over 1,831 non-timeout rounds with a previous round, with current win probability as a covariate (reading…

    Results, Dissociable OFC Encoding of Past Choice and Outcome Information, paragraph 3behavior-past-no-effect
    From the paper

    Random effects logistic regression showed that none of the past trial characteristics significantly affected risk-taking

    Reported statistics
    • random effects logistic regression, p > 0.15 (n = 10 patients)
    Result

    Over 1,831 non-timeout rounds with a previous round, with current win probability as a covariate (reading (a)), past risk (beta 1.74, p = 0.015), past chosen value (beta -0.021, p = 0.039) and past RPE (beta 0.017, p = 0.047) are significant at 0.05; the effects are about 0.1 log-odds per SD. Alone (reading (b)), past risk (p = 0.0005) and past chosen value (p = 0.034) are. The paper's all p > 0.15 does not hold under either reading.

    Deviations from the paper’s method
    • The t-1 regressors are built from all rounds with the authors' convention for a previous timeout (0 for choice and outcome regressors), over all non-timeout rounds, not only those with HFA.
  • Not reproduced

    The risk regressor over all trials explains slightly more HFA variance than risk restricted to gamble trials, so risk is encoded whatever the subsequent choice.

    Over the 84 risk-encoding electrodes (selected on all trials), the peak mean %EV in the game epoch is 2.32 for…

    Figure S3A legendfigs3a-risk-all-trials
    From the paper

    The regressor including all trials explains a slightly higher proportion of variance in HFA (%EV), suggesting that risk is encoded regardless of subsequent patient choice

    Result

    Over the 84 risk-encoding electrodes (selected on all trials), the peak mean %EV in the game epoch is 2.32 for all trials and 3.12 for gamble trials only (both at 1,000 ms). Gamble trials are fewer, and the chance peak is also higher for them (2.30 against 1.25), so raw %EV favours the smaller set. With electrodes selected on gamble trials (64), gamble-only gives 3.51 and all trials 1.99. With each chance peak subtracted, all trials come out higher (1.07 against 0.82); the criterion compares raw %EV, so the outcome follows it, but the comparison is confounded by the number of trials. Under the claims file's baseline readings gamble-only is also higher (2.68 against 2.00, 2.88 against 2.54).

  • Not reproduced

    All signals were present in at least 6 of the 10 patients (mean 7.41 plus or minus 0.4).

    Every regressor is present in at least 6 patients (past risk 6, the others 7 to 10).

    Results, Anatomical Distribution of Present and Past Valuation Signals, paragraph 2; Table S2question to the readertables2-patients-coverage
    From the paper

    We found that all signals were present in at least 6 of the 10 patients in our sample (mean = 7.41 ± 0.4; Table S2)

    Result

    Every regressor is present in at least 6 patients (past risk 6, the others 7 to 10). The mean number of patients is 8.62 (SEM 0.27) over the 16 regressors (reading (a)), 8.80 without past risk (b) and 10 over the four groups (c), outside 7.41 plus or minus 0.4 and above the 7.75 Table S2 gives for reading (a). The higher counts follow from the larger numbers of encoding electrodes (fig3-present-encoding). Under the claims file's baseline readings the mean is 8.94 and 8.06 (minimum 8 and 6), also outside the tolerance.

    Deviations from the paper’s method
    • The HFA is used as deposited; the claims file's baseline readings, shown in the notebook, give the same outcome.
  • Not reproduced

    Most electrodes (132 of 192, 68.7%) encoded at least two of the four signal types (choice, outcome, past choice, past outcome) and 30 of 192 (15.6%) encoded all four.

    Under the stepwise selection, 16 electrodes encode one type each (2 choice, 4 past choice, 10 past outcome)…

    Results, Anatomical Distribution of Present and Past Valuation Signals, paragraph 3; Figure 7Ffig7f-multiplexing
    From the paper

    We observed significant overlap in electrode sets, with most electrodes (n = 132/192; 68.7%) encoding at least two types of signals and 15.6% of electrodes (n = 30/192) encoding all four

    Result

    Under the stepwise selection, 16 electrodes encode one type each (2 choice, 4 past choice, 10 past outcome) and none encodes two or more. Under the 5-window selection (variant) 166 of 191 (86.9%) encode two or more types and 65 (34.0%) all four, both above 132 plus or minus 13.2 and 30 plus or minus 3. Under the claims file's baseline readings the stepwise selection again gives 0 and 0, and the 5-window selection 168 and 63, and 147 and 47.

    Deviations from the paper’s method
    • The stepwise selection rests on the assumptions of figs6b-stepwise-similar; the outcome does not, as the 5-window selection fails as well.
    • The HFA is used as deposited; the claims file's baseline readings, shown in the notebook, give the same outcome.
  • Not reproduced

    Electrodes encoding both present and t-1 information were overrepresented, for choice (39 of 120, 32.5%, against an expected 31, p < 0.05) and for outcome (43 of 120, 35.8%, against an expected 34, p < 0.01), chi-square tests; many electrodes still encoded only present or only past information.

    Under the stepwise selection (reading (a)) no electrode encodes both present and past information (16…

    Results, Anatomical Distribution of Present and Past Valuation Signals, paragraph 3; Figure S7 legendfigs7-present-past-overlap
    From the paper

    We found an overrepresentation of electrodes that encoded both t+t-1 regressors both in the case of choice (39/120 or 32.5%, vs. an expected 31/120 or 25.8% under assumption of independence, p<0.05, chi-square test) and outcome information (n=43/120, or 35.8% vs. an expected 34/120 or 28.5% under assumption of independence, p<0.01, chi-square test)

    Reported statistics
    • choice, present and past: chi-square test, p < 0.05
    • outcome, present and past: chi-square test, p < 0.01
    Result

    Under the stepwise selection (reading (a)) no electrode encodes both present and past information (16 electrodes in all), so the test cannot show overrepresentation. Under the 5-window selection (b) 99 of 184 electrodes encode both present and past choice (99.9 expected, p = 0.73) and 101 both present and past outcome (95.7 expected, p = 0.047). Over all 191 (c) these are 99 (96.2 expected, p = 0.31) and 101 (92.2 expected, p = 0.002). No reading gives counts near 39 and 43 with both overrepresented. Under the claims file's baseline readings the stepwise selection again gives 0 and 0; under the 5-window selection (all encoding electrodes) the counts are 108 and 89, and 98 and 65, none overrepresented at p < 0.05.

    Deviations from the paper’s method
    • Reading (a) rests on the assumptions of figs6b-stepwise-similar; the outcome does not, as readings (b) and (c) fail as well. The chi-square test is Pearson's without continuity correction, with Yates' correction shown.
    • The HFA is used as deposited; the claims file's baseline readings, shown in the notebook, give the same outcome.

Not tested in a notebook 6

6 data missing from the dataset

Blocked6

  • Blocked

    The patients' choices were comparable to those of 10 healthy comparison participants (all p > 0.2).

    The data set holds only the 10 patients.

    Data missing from the datasetFigure 1C legend; Results, Economic Choice Behavior in Neurosurgical Patients, paragraph 4fig1c-patients-like-controls
    From the paper

    Subjects' choices were significantly affected by likelihood of winning the gamble ... and were comparable to those of healthy participants (gray line; all p > 0.2)

    Reported statistics
    • not named, p > 0.2 (n = 10 patients and 10 healthy participants)
    Result

    The data set holds only the 10 patients. The 10 healthy participants' choices are not in it (data.zip and ofc_behav_data.zip list files for s01 to s10 only), and the paper names no other deposit.

  • Blocked

    Across all regressors the proportion of encoding electrodes was greater with HFA than with broadband field potentials (mean 20.9% against 3.3%, p < 10^-5, t test), and greater in every instance.

    The data set holds only HFA (game_events_hg, buttonpress_events_hg and their window averages); there is no…

    Data missing from the datasetResults, OFC HFA Reflects Choice- and Outcome-Related Valuation Signals, paragraph 4; Figure S4Ahfa-more-than-fp
    From the paper

    Across all regressors, the proportion of encoding electrodes identified using HFA was significantly greater than using FP (mean HFA = 20.9% versus FP = 3.3%

    Reported statistics
    • t test, p < 10⁻⁵ (n = not stated; read as 16 regressors (8 current, 8 t-1))
    Result

    The data set holds only HFA (game_events_hg, buttonpress_events_hg and their window averages); there is no broadband field potential or raw voltage, and the paper names no other deposit. The HFA side alone gives a mean proportion of encoding electrodes over the 16 current and t-1 regressors of 33.3% (from the tables of fig3-present-encoding and fig4-past-encoding), against the paper's 20.9%. Under the claims file's baseline readings it is 31.1 and 25.8%, also outside 20.9 plus or minus 2.09.

  • Blocked

    Broadband power modulation across OFC was maximal at the button press and weak at the time of maximal HFA outcome encoding (about 750 ms after outcome reveal), so HFA encoding is distinct in time from broadband modulation.

    No broadband signal is in the data set. The HFA side can be measured; the mean %EV of the outcome regressors…

    Data missing from the datasetResults, OFC HFA Reflects Choice- and Outcome-Related Valuation Signals, paragraph 4; Figure S4Bquestion to the readerfigs4b-power-at-buttonpress
    From the paper

    ERP modulation is maximal at the time of button press, and thus does not align in time with maximal encoding of outcome information

    Result

    No broadband signal is in the data set. The HFA side can be measured; the mean %EV of the outcome regressors peaks 800 ms after time 0 of the buttonpress epoch, which the data indicate is the outcome reveal (within 750 plus or minus 75 ms), or 250 ms after a reveal at +550 ms. Under the claims file's baseline readings it peaks at 700 and 800 ms.

  • Blocked

    Most electrodes lay in putative Brodmann area 11 (53 of 192), 13 (40) and 14 (67).

    The data set holds no electrode coordinates, Brodmann labels or anatomy files (the zip members are the HFA mat…

    Data missing from the datasetResults, Anatomical Distribution of Present and Past Valuation Signals, paragraph 1anatomy-brodmann-counts
    From the paper

    The majority of electrodes in our sample were located in putative BA 11 (n = 53 out of 192 total), 13 (n = 40/192), and 14 (n = 67/192)

    Result

    The data set holds no electrode coordinates, Brodmann labels or anatomy files (the zip members are the HFA mat files and behaviour files only), and the paper names no other deposit.

  • Blocked

    Electrodes encoding each signal type (present and past choice and outcome) were found in all three areas (BA 11, 13 and 14), in similar proportions across areas.

    Needs electrode locations, which are not in the data set (see anatomy-brodmann-counts).

    Data missing from the datasetResults, Anatomical Distribution of Present and Past Valuation Signals, paragraph 1; Figure 7B to 7E; Figure S7Afig7-all-areas-similar
    From the paper

    there was strong evidence for the presence of electrodes capturing each type of signal (present and past choice and outcome) across all three areas

    Result

    Needs electrode locations, which are not in the data set (see anatomy-brodmann-counts).

  • Blocked

    There was no consistent evidence for differential encoding of individual valuation components across BA 11, 13 and 14, nor along fronto-posterior or medio-lateral gradients.

    Needs electrode locations and coordinates, which are not in the data set.

    Data missing from the datasetResults, Anatomical Distribution of Present and Past Valuation Signals, paragraph 2; STAR Methods, Anatomical reconstructions; Discussion, paragraph beginning "As electrode locations were based"no-anatomical-gradient
    From the paper

    We found no consistent evidence for differential encoding of individual valuation components across OFC subregions (BA 11/13/14), or across anatomical gradients (fronto-posterior or medio-lateral; STAR Methods)

    Result

    Needs electrode locations and coordinates, which are not in the data set.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Methods not availableThe encoding rule as the Methods give it (p < 0.05 in 5 or more consecutive 200-ms windows stepped by 50 ms, anywhere in either 3-s epoch) classifies 18.2% of electrodes as encoding when the labels are shuffled, more than Table S2 reports for chosen value and past risk. How do the 1,000 shuffles enter the selection? Requiring each electrode to beat its own shuffled null gives counts all below Table S2; the plain rule gives counts above it. Were the windows limited to part of the epochs, or the p-values taken from the shuffles?#
  • Methods not availableFor the stepwise regression, is the longest significant stretch taken within each epoch or across both, and on which HFA (which window or average) are the nested models compared by ANOVA? With a Bonferroni correction over 192 electrodes and 10,000 shuffles, 16 of 191 electrodes keep any regressor here.#
  • Methods not availableFor the nested mixed-effects models, what is the dependent variable in time (each window or an average), are the regressors entered alone or together (gamble is the sum of the win and loss indices, so all 16 cannot be estimated together), are random slopes included, and over what is the Bonferroni correction made? With fixed slopes over electrodes that encode in opposite directions, the result depends strongly on these choices and on the baseline here (3 to 14 of 16 regressors at corrected p < 10^-4 with the deposited HFA, 16 of 16 per window after subtracting each epoch's own 200-ms pre-event baseline).#
  • Methods not availableThe delays and durations of choice and outcome encoding (512.5 and 287 ms; 612.15 and 712.5 ms) are not defined. Are they per regressor, from the mean %EV profile or the share of encoding electrodes, and is the buttonpress epoch locked to the button press or to the outcome reveal?#
  • Methods not availableSTAR Methods say epochs were made using a 200-ms baseline but not which 200 ms or how it was removed. The deposited game epochs are already corrected over [-1000, -800] ms around game presentation, before the fixation cross. Is that the correction the published analyses used, and was the buttonpress epoch corrected with the same window? Subtracting each epoch's own 200 ms before its event changes the outcomes of five claims here (fig4-past-encoding, fig5-past-sustained, figs5d-sharp-boundary, figs6b-stepwise-similar and mixed-effects-robust).#

Questions about the claims 2

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • The criterion takes chance for each regressor as the share of electrodes classified as encoding under the 1,000 label shuffles, and judges a regressor above chance when its count of encoding electrodes exceeds the 95th percentile of that shuffled count. STAR Methods say the shuffled distribution "was taken as the null for that particular regressor-electrode combination", which describes a null per electrode, used in classifying each electrode. Should the encoding rule be read as the 5-window rule tested against each electrode's own shuffled null (so that the counts of Table S2 are electrodes that beat their own null), with the share under shuffles only a false-positive rate?

    Passage. STAR Methods, ECoG analysis and behavioral regression, "False positive rate was determined using a permutation strategy. For each regressor-HFA regression, we shuffled the relationship between behavioral labels and HFA activity 1,000 times. The resulting distribution was taken as the null for that particular regressor-electrode combination."

    Why it matters. The plain 5-window rule classifies 18.2% of electrodes as encoding under shuffled labels, and gives counts above Table S2 for all 8 current regressors (for example risk 84 against 50). Requiring each electrode's longest run to exceed the 95th percentile of its own shuffled runs (the notebook's own-null variant) gives 41, 31, 21, 12, 24, 15, 15 and 17, all below Table S2; it misses the 10% tolerance for 7 of 8 current and 7 of 8 past regressors, so the outcomes would not change on the counts, but the above-chance conditions of fig3-present-encoding and fig4-past-encoding, and the proportions behind fig6-past-short-lived and tables2-patients-coverage, would be judged on a different selection.

    No reader has answered it yet.
  • The claims file's opening comment says the buttonpress epoch is locked to the button press with the outcome "a fixed 550 ms after the press", and the fig3-present-encoding criterion places outcome encoding "after outcome reveal (button press plus 550 ms)". The legends of Figures 3 and 4 put time 0 of the second epoch at the gamble outcome, and STAR Methods describe the epoch as locked to "buttonpress/reward events". Should time 0 of the buttonpress epoch be read as the outcome reveal, so that the delay of outcome encoding is measured from it?

    Passage. Figure 3 legend, outcome regressors "time locked to gamble outcome (t = 0)"; Figure 4A legend, "time locked to game (t = 0, left) and gamble outcome (t = 0, right)"; STAR Methods, "both game presentation (game epoch) and to buttonpress/reward events (buttonpress epoch)".

    Why it matters. With the reveal at time 0, the choice and outcome delays do not differ (p = 0.235 and 0.301 under the two delay readings), which is the claim. With the reveal at +550 ms they differ (p < 0.001 and p = 0.006). The attempt reads time 0 as the reveal, as the data indicate (the gamble outcome is encoded from about 200 ms after it), shows the claims file's timing alongside, and marks the outcome as resting on this reading.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Reward-related HFA encoding in human OFC (Saez et al. 2018)

Tests the findings of Saez, Lin, Stolk, Chang, Parvizi, Schalk, Knight and Hsu (2018) on CRCNS ofc-3, which holds orbitofrontal high-frequency activity epochs and behaviour of 10 epilepsy patients playing a gambling task. It tests the behaviour, the regression of HFA on choice, outcome and past-trial regressors, the timing and duration of encoding, the stepwise and mixed-effects checks and the overlap of electrode sets. The broadband signal, the electrode locations and the healthy participants' data are not in the data set. All files

Environment: Python 3.13, 34 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-13
    Agreed with 28 of 28 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The executed notebook of the first run with the conclusion cells and the summary removed, the helper module and the claims file, with the paper. The verifier tested encoding_scan, longest_run, run_bounds and glmm_logit on synthetic inputs and read the zip directories of the archive by range requests. Its outcomes agree with the record for all 28 claims; it marked mixed-effects-robust provisional. In reply, the revision ran both of the claims file's baseline readings over every test that rests on the encoding scans (a new notebook section), ran every combination of the mixed-effects readings with the nested model, printed the variables of the HFA files and the mean offset between the epochs, checked the trial matching in reverse, added the criterion's non-timeout variant for the regressor R2, and added point 10 to questions/saez-2018.yaml for a reader. No outcome changed; four more outcomes (fig4-past-encoding, fig5-past-sustained, figs5d-sharp-boundary and mixed-effects-robust) are now marked as resting on the deposited baseline, on which figs6b-stepwise-similar also rests. Report in transcripts/saez-2018/verifier-1-report.md.
  • Round 2
    2026-11-13
    Agreed with 27 of 28 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook of the revision after round 1, with its conclusions and summary, the helper module, the claims file, the README and this record, with the paper. The verifier agrees with 27 of the 28 outcomes and disagrees with mixed-effects-robust, which it would give as reproduced (assumed) under the claims file's baseline reading (a). It also found that baseline reading (b) was not cleanly applied to the buttonpress epoch, which carries its own per-trial offset. In reply, the revision keeps every verified outcome and proposes reproduced for mixed-effects-robust under proposed; it measures the buttonpress epoch's per-trial, per-electrode offset on every trial where the two epochs overlap (1,572 of 1,753 trials; the electrode's median elsewhere) and re-runs baseline reading (b) with it, which changes no outcome; it prints reveal.time per subject (the finding is corrected), the pair behind the averaged maximum R2, and the largest corrected p of the mixed models under each baseline; it corrects the sentences the report quotes; it removes the assumed flag from fig7f-multiplexing and figs7-present-past-overlap; and it adds the verifier's round-1 point 3 to questions/saez-2018.yaml for a reader. Report in transcripts/saez-2018/verifier-2-report.md.
    • mixed-effects-robust: the verifier’s outcome was “Reproduced”. The claims file says it is reproduced when, under one reading, every regressor has corrected p < 10^-4, and lists baseline (a) as an allowed reading. Under baseline (a), one model per window with one regressor and all electrodes makes all 16 significant. The implementation of baseline (a) is exact, as subtracting the window centred at -100 ms removes any constant per-trial offset. The record treats the deposited baseline as the only primary analysis; for this claim that blocks a pass a claims-file reading gives. The outcome should be reproduced, with assumed true, resting on baseline reading (a) and the per-window Bonferroni reading. The text says the fit "matches statsmodels MixedLM to the printed digits"; cell 85 shows small differences.
  • Round 3
    2026-11-13
    Agreed with 1 of 1 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 3. Only the change of outcome proposed after round 2, for mixed-effects-robust, with the executed notebook, the helper module, the claims file and the paper. Report in transcripts/saez-2018/verifier-3-report.md.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • The HFA is used as deposited, as the authors' own baseline correction (an assumption): the game epoch is corrected over [-1000, -800] ms (its first window is the same in every trial) and the buttonpress epoch carries a per-trial offset close to it. STAR Methods say only that epochs were made "using a 200-ms baseline to remove any pre-stimulus differences in baseline amplitude", and the data description that "activity for both epochs is temporally aligned". The claims file's readings, (a) the 200 ms before each epoch's event and (b) the 200 ms before game presentation for both epochs (the buttonpress epoch first put on the game epoch's level with its per-trial, per-electrode offset, measured where the epochs overlap), are applied on top of it in the notebook's section Baseline readings.fig3-present-encoding fig4-past-encoding fig5-past-sustained figs5d-sharp-boundary figs6b-stepwise-similar
  • The HFA is used as deposited; the claims file's baseline readings, shown in the notebook, give the same outcome.fig3-latency-duration-similar tables2-patients-coverage fig7f-multiplexing figs7-present-past-overlap
  • The electrode count of 192 is the deposited count with the seven copied electrodes of s03 removed; the analysis itself uses 191, counting each recording once.methods-electrode-trial-counts
  • The random-effects logit is fitted by maximum likelihood with Gauss-Hermite quadrature (20 points, or 12 by 12 with a random slope) in the helper, with Wald tests from a numerical Hessian; the paper used R and does not name the routine. A standard choice.fig1c-choice-win-probability
  • Game presentation is taken as the csv column choice.time, which the data description does not list; it is 0.66 to 0.97 s after trial start, near the paper's 750 ms.figs2b-rt-conflict
  • RT is taken as buttonpress.time minus choice.time, an inference from the data; the description does not define these columns.figs2b-rt-conflict
  • The analysis uses 191 electrodes (the paper 192); s03 electrode 42 holds no data of its own.fig3-present-encoding
  • The buttonpress epoch's time 0 is read as the outcome reveal, as the data indicate; the claims file's timing (reveal 550 ms after time 0) is shown alongside, and the timing condition holds under both.fig3-present-encoding
  • The outcome rests on the reading of the buttonpress epoch as locked to the outcome reveal. The data description says the epoch is centred on the button press; the data show it is centred 470 to 600 ms after the csv's button press and that the gamble outcome is encoded from about 200 ms after its time 0, which fits a reveal-locked epoch, and the paper's Figure 3C labels the epoch "time locked to gamble outcome (t = 0)". The true event times are not in the files.fig3-latency-duration-similar
  • Delay and duration are measured on windows that start at or after the event; the chance profile is the mean %EV of the electrodes selected under the 1,000 shuffles, and the chance share for reading (b) the 95th percentile of the shuffled share per window. Standard choices, as the paper does not define them.fig3-latency-duration-similar
  • The t-1 regressors are the authors' file values, which keep rounds after a timeout with 0 for the choice and outcome regressors. The analysis uses 191 electrodes.fig4-past-encoding
  • The t-1 regressors are built from all rounds with the authors' convention for a previous timeout (0 for choice and outcome regressors), over all non-timeout rounds, not only those with HFA.behavior-past-no-effect
  • Lags t-2 to t-5 are built from the rounds, as the data set's regressor file holds t-1 only.fig6-past-short-lived
  • The HFA is used as deposited, as the authors' own baseline correction (an assumption): the game epoch is corrected over [-1000, -800] ms (its first window is the same in every trial) and the buttonpress epoch carries a per-trial offset close to it. STAR Methods say only that epochs were made "using a 200-ms baseline to remove any pre-stimulus differences in baseline amplitude", and the data description that "activity for both epochs is temporally aligned". The claims file's readings, (a) the 200 ms before each epoch's event and (b) the 200 ms before game presentation for both epochs (the buttonpress epoch first put on the game epoch's level with its per-trial, per-electrode offset, measured where the epochs overlap), are applied on top of it in the notebook's section Baseline readings. The outcome rests on baseline reading (a), which the claims file names, with one model per window (assumed).mixed-effects-robust
  • The nested model is fitted by REML in closed form (helper nested_lmm), which uses the fact that every electrode of a patient shares its trials and regressors; it is checked against statsmodels MixedLM in the notebook. A standard choice.mixed-effects-robust
  • Time point (b) fits each epoch and counts a regressor when significant in either, with the correction over 16 regressors and 2 epochs. The joint model leaves out the two gamble regressors, which are the sums of the win and loss indices and cannot be estimated with them.mixed-effects-robust
  • Assumed, as STAR Methods do not say, that the longest significant stretch is taken in each epoch and the larger sum of F used, and that the model comparison (ANOVA) is made on the HFA of the window where the base regressor has its peak %EV. Other readings (a stretch across both epochs, comparisons at each regressor's own peak) were not run; the permutation step, which leaves only 16 electrodes, does not depend on the second choice.figs6b-stepwise-similar
  • The Bonferroni correction uses the 191 electrodes analysed; the paper says 192.figs6b-stepwise-similar
  • The response side is the csv's choice.location.figs3b-no-motor-encoding
  • The stepwise selection rests on the assumptions of figs6b-stepwise-similar; the outcome does not, as the 5-window selection fails as well.fig7f-multiplexing
  • Reading (a) rests on the assumptions of figs6b-stepwise-similar; the outcome does not, as readings (b) and (c) fail as well. The chi-square test is Pearson's without continuity correction, with Yates' correction shown.figs7-present-past-overlap

Provenance

Attempt record
saez-2018-01
Paper
10.1016/j.cub.2018.07.045
Date
2026-11-13
Made by
An agent, run by CatalystNeuro
Dataset
CRCNS:ofc-3 (on CRCNS)
Version
unversioned (doi:10.6080/K0VM49GF)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-15

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 10 findings reproduced, Saez et al. 2018

It counts the paper’s findings reproduced in full in a current attempt, verified or not. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/saez-2018/"><img src="https://encorescience.org/badge/papers/saez-2018-reproduced.svg" alt="Encore: 10 findings reproduced, Saez et al. 2018"></a>

Or as Markdown:

[![Encore: 10 findings reproduced, Saez et al. 2018](https://encorescience.org/badge/papers/saez-2018-reproduced.svg)](https://encorescience.org/papers/saez-2018/)

The same numbers are in this page’s JSON, under badge (how it is counted).