Papers / Ramachandran et al. 2025

Ramachandran et al. 2025 · Journal of Neural Engineering

Parameter-dependent cell-type specific effects of transcranial focused ultrasound stimulation in an awake head-fixed rodent model

Sandhya Ramachandran, Huan Gao, Eric A. Yttri, Kai Yu, Bin He

Outcomes of 22 claims

  • 1 reproduced
  • 1 partially reproduced
  • 11 not reproduced
  • 9 blocked

Summary: Most main findings did not hold in this data, one held only on an assumption, and the sham and cell-type sorting findings could not be tested. Time-locked RSU responses peaked at 3000 Hz, not 1500 Hz (107.7 to 108.7%). FSU time-locked responses differed across PRF, and awake FSU delayed onsets were not later than anesthetized ones. Anesthesia lowered delayed responses in both cell types only if one recording per rat and condition is assumed, which the paper does not state. The sham, the second batch of rats and the waveforms are missing, and the anesthetized data come from two rats, not ten.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Ramachandran et al. (2025) from dandiset 000945 20 Open in Colab

Reproduced1

  • Reproduced

    Anesthesia is a significant factor in the delayed response for both RSUs and FSUs by two-way ANOVA, and it lowers the average response magnitude.

    With one recording per rat and condition, either without the `_2` recordings (Rep2) or with the earliest of…

    Results 3.2, paragraph 2; Discussion, paragraph beginning 'Although these results demonstrate'rests on an assumptiondelayed-anesthesia-factor
    From the paper

    Using two-way ANOVA, we found that anesthesia is a significant factor in the delayed response for both RSU ... and FSU

    Reported statistics
    • RSU: two-way ANOVA, anesthesia factor, p < 0.001
    • FSU: two-way ANOVA, anesthesia factor, p < 0.01
    Result

    With one recording per rat and condition, either without the `_2` recordings (Rep2) or with the earliest of each pair (Rep3), anesthesia is a factor for RSU at p = 4.2e-09 to 1.8e-08 and for FSU at p = 0.0012 to 0.0015 under A1/A2 and W1/W2, and the anesthetized mean is lower in both (RSU 99.7 against 104.3 to 104.6%, FSU 99.7 against 101.2 to 101.3%). With every recording (Rep1) RSU holds (p = 3.6e-06 to 4.3e-06) but FSU gives p = 0.038 to 0.041, which misses the 0.01 bound; that reading gives partially reproduced. Leaving out the recording filed under both BH498 and BH508 gives FSU p = 0.0016 to 0.0019 under Rep2 and Rep3, and 0.048 to 0.052 under Rep1 (above 0.05 under W2), where the RSU part alone still holds and the criterion gives partially reproduced ("when one cell type holds"). With every recording the claim is thus partial at best, so the reproduced outcome rests on the assumption. The anesthetized units come from two rats, so the state effect may also be a rat effect. The question is recorded for the paper's authors.

    Deviations from the paper’s method
    • Assumed that the paper's analysis used one recording per rat and condition. The paper mentions no repeats, Methods 2.3 fits one recording per parameter set per rat without stating it ("Recordings for a single rat for each set of parameters were completed on the same day" says when a rat's recordings were made, so it supports the assumption only weakly), and the dandiset's description says "Some subjects have duplicate recordings taken a few months after the original ones". Which recording of a pair is the original is open, as three `_2` recordings are earlier than their pair; both choices (Rep2, Rep3) give the same outcome.
    • Anesthetized units from two rats.

Partially reproduced1

  • Partially reproduced

    Awake FSU delayed responses are significantly higher at 60% DC than at 6%, and at 6% DC they do not differ from sham.

    Parts (1) and (2) hold under every reading, without a 30% group included, so they do not depend on the…

    Results 3.3, paragraph 1; Figure 7Dverifier disagreed at firstfig7d-fsu-delayed-dc
    From the paper

    Delayed responses from FSUs showed a significantly higher response to 60% DC over 6% ... with 6% DC found to be not significantly different from sham

    Reported statistics
    • Kruskal-Wallis with post hoc Wilcoxon, p < 0.001, Bonferroni-corrected
    Result

    Parts (1) and (2) hold under every reading, without a 30% group included, so they do not depend on the substitute; the Kruskal-Wallis is significant (p = 0.0051 without a 30% group, 0.011 C1, 4.5e-07 to 1.4e-06 C2) and 60% is above 6% (p = 0.0051 alone, corrected p = 0.015 over three pairs). Part (3), 6% against sham, cannot be tested, so the claim is partially reproduced, the outcome the criterion gives when (1) and (2) hold without (3). The difference is small and both groups are below baseline (99.6% and 98.2%).

    Deviations from the paper’s method
    • No sham recording; part (3) is reported as not tested.
    • The 30% group is a substitute (C1 or C2) or absent (C0); it enters only the Kruskal-Wallis.

Not reproduced11

  • Not reproduced

    FSU delayed responses to tFUS at 1500 Hz PRF begin later in awake rats (mean onset 0.51 s, spread 0.14 s) than under anesthesia (0.24 s, spread 0.08 s), and the onset distributions differ significantly by a Wilcoxon rank-sum test.

    Under none of the 24 readings (S1/S2, D1/D2, L1/L2, Rep1/Rep2/Rep3) are awake onsets later at p < 0.001…

    Results 3.1, paragraph 1; Figure 4H and 4Ifig4hi-fsu-delayed-latency
    From the paper

    In the anesthetized model, these delayed responses had an average onset latency of 0.24 s ± 0.08 s, while in the awake model they had an average onset latency of 0.51 s ± 0.14 s ... Comparing the distributions using the Wilcoxon rank-sum test, we found that delayed response onset times varied significantly between awake and anesthetized models

    Reported statistics
    • Wilcoxon rank-sum test, p < 0.001 (n = FSU with a significant delayed response at 1500 Hz PRF, awake and anesthetized (counts not given))
    • as printed in the Figure 4 legend: Wilcoxon rank sum test, p < 10⁻⁴
    Result

    Under none of the 24 readings (S1/S2, D1/D2, L1/L2, Rep1/Rep2/Rep3) are awake onsets later at p < 0.001; rank-sum p is 0.018 to 0.92, and in 8 readings the anesthetized mean is the later. Awake means are 0.40 to 0.58 s (within 0.51 +- 0.14), anesthetized means 0.38 to 0.52 s (all outside 0.24 +- 0.08). Measured values are the S1 D1 L1 Rep1 means (anesthetized, awake). 193 to 265 of 306 awake FSU (86% under S1 D1) and 34 or 39 of 50 anesthetized FSU have a delayed response under the paper's rule as the claims file reads it, and latencies spread over 0.07 to 1.39 s in both states, so the rule flags most units and the onsets look largely noise-driven. The anesthetized FSU come from two rats (BH498, BH512). Q1 and Q2 select the same recordings here.

    Deviations from the paper’s method
    • The anesthetized FSU come from two labelled rats where the paper had ten; batch 2 is not in the dandiset.
    • T2 (505 trials) cannot be run; the files hold 500 trials, or fewer in five recordings.
  • Not reproduced

    In awake rats PRF is a significant factor for RSU time-locked responses; 30 Hz and 300 Hz PRF give lower responses than every higher PRF (so 30 Hz is also below 300 Hz), 1500, 3000 and 4500 Hz do not differ, and sham differs from every PRF but 30 Hz.

    PRF is a significant factor (Kruskal-Wallis p = 3.3e-16, W1 Rep1) but the post hoc pattern differs.

    Results 3.2, paragraph 1; Figure 5Afig5a-rsu-time-locked-prf-awake
    From the paper

    Examining the time-locked response from RSU in the awake model using Kruskal–Wallis ANOVA, we find that PRF is a significant factor ... Post hoc tests show that 30 Hz and 300 Hz PRF induced responses lower than all higher PRFs ... The sham condition was significantly different than all but the 30 Hz condition ... 1500 Hz, 3000 Hz, and 4500 Hz showed no significant differences

    Reported statistics
    • PRF as a factor: Kruskal-Wallis, p < 0.001
    • 30 and 300 Hz against each higher PRF: post hoc Wilcoxon, p < 0.001, Bonferroni-corrected
    • sham against 300, 1500, 3000 and 4500 Hz: post hoc Wilcoxon, p < 0.001, Bonferroni-corrected
    Result

    PRF is a significant factor (Kruskal-Wallis p = 3.3e-16, W1 Rep1) but the post hoc pattern differs. The highest mean is at 3000 Hz (108.2%; 1500 Hz 98.5%), and 3000 Hz differs from 1500 and 4500 Hz, so part (4) fails under every reading; part (3) fails under every reading; part (2) holds only under W2 Rep1 and W2 Rep3. Parts (5) and (6) need the sham and were not tested; even if both held, part (1) with at most three others falls short of the four the partial outcome needs.

    Deviations from the paper’s method
    • No sham recording exists; parts (5) and (6) are reported as not tested, and a claim with an untested part is not judged reproduced.
    • Ten awake recordings repeat a condition in the same rat; results are given with them (Rep1), without the `_2` recordings (Rep2) and with the earliest recording of each pair (Rep3).
  • Not reproduced

    Under anesthesia RSU time-locked responses depend on PRF as in the awake model, the only difference being that 30 Hz and 300 Hz do not differ significantly.

    The Kruskal-Wallis is significant (p = 7.3e-08 W1, 7.7e-07 W2) and 30 and 300 Hz do not differ (part 7), but…

    Results 3.2, paragraph 1; Figure 5Cfig5c-rsu-time-locked-prf-anesth
    From the paper

    The anesthetized model had similar statistical results, with the only difference being that no significant difference was observed between 30 Hz and 300 Hz PRF levels

    Result

    The Kruskal-Wallis is significant (p = 7.3e-08 W1, 7.7e-07 W2) and 30 and 300 Hz do not differ (part 7), but parts (2), (3) and (4) fail under both readings. 1500 Hz is the peak (107.0%) and differs from 4500 Hz; 30 and 300 Hz are not below 3000 or 4500 Hz. Even if the two sham parts held, part (1) with three others falls short of the five the partial outcome needs. With two rats PRF and rat are confounded, as the 30 Hz group is BH498 alone and the 1500 Hz peak comes from BH512 (110.4% against 101.7% in BH498, whose means span 100.0 to 101.7%).

    Deviations from the paper’s method
    • Two labelled rats (BH498 at five PRFs, BH512 without 30 Hz) where the paper had ten; BH521's anesthetized recordings have no labels.
    • Parts (5) and (6) need the sham and were not tested.
  • Not reproduced

    Anesthesia is a significant factor in the RSU time-locked response by two-way ANOVA, and it lowers the average magnitude of RSU responses.

    Anesthesia is a factor at p = 0.0083 to 0.018 over the twelve readings (A1/A2, W1/W2, Rep1/Rep2/Rep3), below…

    Results 3.2, paragraph 1; Discussion, paragraph beginning 'Although these results demonstrate'rsu-time-locked-anesthesia-factor
    From the paper

    Two-way ANOVA additionally finds that anesthesia is a significant factor in the time-locked response from RSU ... Anesthesia was observed to decrease the average magnitude of RSU responses

    Reported statistics
    • two-way ANOVA, anesthesia factor, p < 0.01
    Result

    Anesthesia is a factor at p = 0.0083 to 0.018 over the twelve readings (A1/A2, W1/W2, Rep1/Rep2/Rep3), below 0.01 only under W1 Rep3, and in the reverse direction under every reading; the anesthetized mean (102.6 to 102.9%) is above the awake mean (100.1 to 100.4%). The anesthetized units come from two rats and the awake units from seven, so the state effect is partly a rat effect; with only BH498 and BH512 it disappears (p = 0.425).

    Deviations from the paper’s method
    • Anesthetized units from two rats; awake units from seven.
  • Not reproduced

    FSU time-locked responses show no significant differences across PRF levels, in either the awake or the anesthetized model.

    By the paper's test FSU time-locked responses differ across PRF in both states, Kruskal-Wallis p = 1.8e-12…

    Results 3.2, paragraph 1; Figure 5B and 5Dfig5bd-fsu-time-locked-no-prf
    From the paper

    FSU in both the awake and the anesthetized model show no significant differences due to PRF levels

    Result

    By the paper's test FSU time-locked responses differ across PRF in both states, Kruskal-Wallis p = 1.8e-12 awake and 5.5e-04 anesthetized (W1 Rep1), with 4 to 6 significant post hoc pairs awake and 2 or 3 anesthetized under every reading. The effects are small; group medians span 98.7 to 103.4% awake and 99.8 to 103.9% anesthetized, and the awake 3000 Hz mean is 106.8%. G2 (with sham) cannot be run. The anesthetized groups come from two rats.

  • Not reproduced

    Awake FSU delayed responses depend on PRF, are strongest at 4500 Hz, differ between 30 Hz and the three highest PRFs and between 300 Hz and the two highest, and at 30 Hz and 300 Hz are not significantly higher than sham.

    PRF is a significant factor (p = 4.6e-12 Rep1) and 30 Hz differs from 1500, 3000 and 4500 Hz (part 3, tested…

    Results 3.2, paragraph 2; Figure 5Ffig5f-fsu-delayed-prf-awake
    From the paper

    FSUs in the awake model show the strongest responses to 4500 Hz PRF, with significant differences between 30 Hz and the highest three PRFs, and 300 Hz and the highest two PRFs ... 30 Hz and 300 Hz were not found to be significantly higher than sham

    Reported statistics
    • post hoc Wilcoxon, p < 0.001, Bonferroni-corrected
    Result

    PRF is a significant factor (p = 4.6e-12 Rep1) and 30 Hz differs from 1500, 3000 and 4500 Hz (part 3, tested without direction as the criterion says "differs"), but the strongest mean is at 30 Hz (103.5%, 4500 Hz 100.3 to 100.4%), the opposite of the paper's pattern, and 300 Hz does not differ from 4500 Hz (corrected p = 1.0), under every repeat reading. Part (5) needs the sham and was not tested; even if it held, part (1) with two others falls short of the three the partial outcome needs.

  • Not reproduced

    Under anesthesia PRF is a significant factor for the delayed responses (0.2 to 0.7 s) of both RSUs and FSUs, which broadly prefer higher PRFs.

    PRF is not a significant factor for anesthetized delayed responses, Kruskal-Wallis p = 0.16 (W1) and 0.12 (W2)…

    Results 3.2, paragraph 2; Figure 5G and 5Hfig5gh-delayed-prf-anesth
    From the paper

    PRF was found to be a significant factor for RSU and FSU in both awake and anesthetized settings ... Both RSUs and FSUs in the anesthetized rats had similar sensitivity as their time-locked responses, broadly preferring higher PRFs

    Result

    PRF is not a significant factor for anesthetized delayed responses, Kruskal-Wallis p = 0.16 (W1) and 0.12 (W2) for RSU, 0.16 and 0.18 for FSU. The higher PRFs have the higher pooled mean by under one point (RSU 99.97 against 99.15%, FSU 99.87 against 99.35%). Every rat and PRF mean is within 98.5 to 100.9%, and the 30 Hz group is BH498 alone.

    Deviations from the paper’s method
    • Two labelled rats where the paper had ten.
  • Not reproduced

    Awake FSUs show no time-locked response, and their delayed response increases almost linearly with ISPTA.

    The time-locked part fails (fig5bd, awake Kruskal-Wallis p = 1.8e-12).

    Results 3.2, paragraph 4; Figure 6F and 6Hfig6fh-fsu-ispta
    From the paper

    FSU's show no time-locked response, and their delayed response increases almost linearly with I SPTA .

    Result

    The time-locked part fails (fig5bd, awake Kruskal-Wallis p = 1.8e-12). Delayed FSU means are 103.5, 98.7, 101.8, 100.6 and 100.3% from 30 to 4500 Hz (Spearman rho = -0.4, Pearson r = -0.27, Rep1; rho = -0.3 Rep2 and Rep3).

  • Not reproduced

    Among PRFs, 1500 Hz gives the highest mean RSU time-locked response in awake rats, although not significantly above 3000 and 4500 Hz.

    The highest mean is at 3000 Hz under every reading (107.7 to 108.7%), significantly above 1500 Hz (98.1 to…

    Results 3.2, paragraph 4; Figure 5Afig5a-1500-highest-time-locked-mean
    From the paper

    Although it is not statistically significant, we found that 1500 Hz produces the highest mean time-locked response

    Result

    The highest mean is at 3000 Hz under every reading (107.7 to 108.7%), significantly above 1500 Hz (98.1 to 98.7%; corrected p = 0.0040 or less).

  • Not reproduced

    By mean values 60% DC gives the strongest RSU time-locked response, though it is only significantly higher than 6%.

    The highest mean is at 6% under every reading (176.3 to 180.8%; 60% 147.1 to 147.5%), which does not need the…

    Results 3.3, paragraph 1; Figure 7Afig7a-60-highest-time-locked-mean
    From the paper

    Based on mean values, 60% DC appears to produce the strongest time-locked response, although it is only statistically significantly higher than the 6% condition.

    Result

    The highest mean is at 6% under every reading (176.3 to 180.8%; 60% 147.1 to 147.5%), which does not need the 30% group. With the substitute 30% groups, 60% is significantly above 30% (corrected p < 1e-16).

    Deviations from the paper’s method
    • The 30% group is a substitute (C1 or C2) or absent (C0), as for fig7a.
  • Not reproduced

    FSUs show no time-locked response across DC levels; no significant differences are observed.

    FSU time-locked responses differ across DC under every reading, and the 6% against 60% difference does not…

    Results 3.3, paragraph 1; Figure 7Bfig7b-fsu-time-locked-dc
    From the paper

    no time-locked response was observed as in the PRF study

    Result

    FSU time-locked responses differ across DC under every reading, and the 6% against 60% difference does not need the 30% group (Kruskal-Wallis p = 0.0054 without it; p = 3.5e-12 or smaller with a substitute, all three pairs significant). FSU respond strongly at 6% and 60% (means 156.8 and 205.3%, medians 115.0 and 128.6%) and not at the substitute 30% (median 100.8%), most in BH506 (338.6 and 403.3%).

    Deviations from the paper’s method
    • The 30% group is a substitute (C1 or C2) or absent (C0), as for fig7a.

Blocked7

  • Blocked

    Units are sorted into fast spiking units (FSU) and regular spiking units (RSU) by k-means clustering of the initial phase and after-hyperpolarization phase durations of their action potentials; in one animal's recordings this gave 28 FSU and 32 RSU, 60 in total.

    Both the reproduced and the partially reproduced outcome of the criterion require the clusters to separate on…

    Data missing from the datasetFigure 3B and 3C; Methods 2.5verifier disagreed at firstfig3-cell-type-sorting
    From the paper

    K -means clustering of detected neurons from one animal's recordings, showing 28 fast spiking units (FSU) and 32 regular spiking units (RSU), for 60 total.

    Result

    Both the reproduced and the partially reproduced outcome of the criterion require the clusters to separate on the initial phase and after-hyperpolarization durations, and the files hold no waveforms, so K1 and K2 cannot run and neither outcome can be reached. With the dataset's labels (K0) two single recordings (R1) give all three counts within tolerance, BH527_30_200 with 28 FSU, 34 RSU and 62 units (given as measured) and BH508_4500_200_2 with 28 FSU, 30 RSU and 58 units; under Rep2 and Rep3 only BH527_30_200 does. No rat's series matches (R2; totals 77 to 616). The match is no more than chance, as 22 of 59 recordings have a total within 60 +- 6 and a binomial model with the pooled FSU share (0.505) expects 3.84 recordings to match all three counts, against 2 observed. FSU have the higher median baseline rate in 46 of 59 labelled recordings (8.60 against 5.84 Hz over units).

    Deviations from the paper’s method
    • Cell types are the dataset's labels (K0); that they are the paper's k-means output is assumed, and is consistent with the baseline rates without being shown.
    • The other claims depend on this one for cell types. They use the K0 labels, as the claims file's header provides when the dataset carries labels, and do not need the waveform features whose absence blocks this claim, so they are tested.
  • Blocked

    RSUs show time-locked responses to tFUS, an increase in firing rate during the 67 ms of stimulation, in both awake and anesthetized recordings.

    The criterion compares the 1500 Hz, 200 us RSU time-locked responses with the sham sessions of each state, and…

    Data missing from the datasetResults 3.1, paragraph 1; Figure 4C and 4Efig4-rsu-time-locked-both-states
    From the paper

    We observed time-locked responses from RSU in both awake and anesthetized recordings, with an observable increase in firing rate during tFUS stimulation

    Result

    The criterion compares the 1500 Hz, 200 us RSU time-locked responses with the sham sessions of each state, and the dandiset holds no sham recording. The awake half already fails the condition that the 1500 Hz mean be above 100%, as RSU at 1500 Hz average 98.1 to 98.7% of baseline awake under every reading (n = 227 or 303), so the claim could not be reproduced whatever a sham would show; at best it would be partially reproduced, on the anesthetized half (106.4 to 107.0%, n = 78, two rats).

  • Blocked

    Awake FSU delayed-response onset latencies have a wider spread than anesthetized ones and appear to have two peaks.

    The claims file's readings give different results, and its header blocks a claim whose readings disagree.

    Methods underspecifiedResults 3.1, paragraph 1; Figure 4Hverifier disagreed at firstfig4h-awake-latency-wider
    From the paper

    The awake model had a wider variance of onset latencies, and appears to have two peaks

    Result

    The claims file's readings give different results, and its header blocks a claim whose readings disagree. The awake SD exceeds the anesthetized SD under every D1 reading (0.384 to 0.396 s against 0.367 to 0.372 s) but is smaller under 10 of 12 D2 readings (0.381 to 0.393 s against 0.393 to 0.406 s) and larger by under 0.001 s in the other two. Under every reading the SDs are within 0.03 s of each other, with no contrast like the paper's 0.14 against 0.08 s. The awake histogram (S1 D1 L1 Rep1) has its largest count in the first allowed bin (61 of 262 at 0.071 s) and several smaller local maxima. Whether the first bin allowed is one starting at or after 67 ms (D1) or one ending after it (D2) is asked of the paper's authors.

  • Blocked

    Awake RSU delayed responses (0.5 to 1 s) depend on PRF, are highest at 1500 Hz and 3000 Hz with lower responses at both lower and higher PRFs, and every PRF is significantly higher than sham.

    PRF is a significant factor (p = 6e-20 Rep1, 4.5e-15 Rep2, 5.1e-15 Rep3) but the two highest means are 1500…

    Data missing from the datasetResults 3.2, paragraph 2; Figure 5Everifier disagreed at firstfig5e-rsu-delayed-prf-awake
    From the paper

    RSUs in the awake rats had highest responses to 1500 Hz and 3000 Hz ... with a decrease at both higher and lower frequencies, and all conditions found to be significantly higher than sham

    Reported statistics
    • 1500 and 3000 Hz highest: post hoc Wilcoxon, p < 0.001, Bonferroni-corrected
    • each PRF against sham: post hoc Wilcoxon, p < 0.001, Bonferroni-corrected
    Result

    PRF is a significant factor (p = 6e-20 Rep1, 4.5e-15 Rep2, 5.1e-15 Rep3) but the two highest means are 1500 and 30 Hz (106.7 and 106.6% Rep1), and 3000 Hz (102.3 to 103.3%) is below 30 Hz (corrected p < 1e-4); part (2) fails under both of its readings and every repeat reading. Part (3), every PRF above sham, needs the sham and cannot be tested. The criterion gives partially reproduced when (1) and (3) hold without (2), so the outcome would be partial if a sham held and not reproduced otherwise, and the data present do not decide between the two. The claim is therefore blocked as data missing, as fig4-rsu-time-locked-both-states is.

  • Blocked

    Awake RSU mean responses, time-locked and delayed, rise with ISPTA up to around 60 mW/cm2 and then decline.

    The delayed means do not rise to their peak under any reading (106.6% at 30 Hz, 101.2 to 102.8% at 300 Hz…

    Methods underspecifiedResults 3.2, paragraph 4; Figure 6E and 6Gverifier disagreed at firstfig6ef-rsu-ispta-rise-then-fall
    From the paper

    We observe that RSU's in both their time-locked and delayed responses initially increase till around 60 mW cm −2 , after which the response declines.

    Result

    The delayed means do not rise to their peak under any reading (106.6% at 30 Hz, 101.2 to 102.8% at 300 Hz, 106.7 to 108.8% at 1500 Hz), so at best the claim is partially reproduced, on the time-locked window. Time-locked RSU means rise from 30 Hz (96.4 to 96.8%) to a peak at 3000 Hz (60.26 mW/cm2, 107.7 to 108.7%) and fall at 4500 Hz (98.0 to 99.5%) under W2 with every repeat reading and under W1 with Rep1 and Rep3, but under W1 Rep2 the 300 Hz mean (98.2%) is 0.1 point above the 1500 Hz mean (98.1%, SEMs 1.1 and 1.3). With one recording per rat and condition the claims file's readings W1 and W2 thus disagree under Rep2, and its header blocks a claim whose readings disagree. How a window off the bin edges was measured is asked of the paper's authors.

  • Blocked

    Awake RSU time-locked responses at 1500 Hz PRF are significantly lower at 6% DC than at 60% DC (and, by the Figure 7A legend, than at 30% DC), and every DC is significantly higher than sham.

    Part (2) does not need the 30% group and fails under every reading, as 6% is the highest group (180.8%; 60%…

    Data missing from the datasetResults 3.3, paragraph 1; Figure 7A and its legendverifier disagreed at firstfig7a-rsu-time-locked-dc
    From the paper

    Time-locked responses from RSUs showed a significantly lower response to 6% DC than those to 60%, with all conditions significantly higher than sham

    Reported statistics
    • Kruskal-Wallis with post hoc Wilcoxon, p < 0.001, Bonferroni-corrected
    Result

    Part (2) does not need the 30% group and fails under every reading, as 6% is the highest group (180.8%; 60% 147.5%) and does not differ from 60% (corrected p = 1.0; 0.67 to 0.91 without a 30% group). Part (1), the Kruskal-Wallis over 6, 30 and 60%, needs the 30% group (p = 0.67 and 0.91 without it, 1.5e-22 or smaller with a substitute, so the substitutes alone decide it), part (4), 6% below 30%, needs it too, and part (3) needs the sham, so parts (1), (3) and (4) are untested. The criterion gives partially reproduced when (1) and at least one of (2) to (4) hold, so partial is reachable if (1) and (3) or (4) held, and the data present do not decide it. The claim is therefore blocked as data missing, as fig7c-rsu-delayed-dc is. The substitute 30% groups are far below both (90.4 to 98.7%). The 6% and 60% responses are largest in BH506 (249.0 and 209.9%); BH521 and BH526 give 113 to 121%.

    Deviations from the paper’s method
    • The dandiset has no 30% DC recording of its own. The substitutes (C1, the PRF series' 1500 Hz, 200 us recordings of BH506 and BH526; C2, those of every rat, with each repeat reading) and C0, no 30% group, are shown; a part that needs the 30% group is treated as data missing.
    • The 6% and 60% recordings come from three rats where the paper had ten.
  • Blocked

    Awake RSU delayed responses prefer 30% DC over 6% and 60%, all three DCs differ (Figure 7C legend), and at 60% DC they do not differ from sham.

    Part (2), 30% above 6% and 60%, needs the paper's 30% DC recordings, which are not in the dandiset, and the…

    Data missing from the datasetResults 3.3, paragraph 1; Figure 7C and its legendverifier disagreed at firstfig7c-rsu-delayed-dc
    From the paper

    Delayed responses however preferred 30% DC over 6% and 60% ... and 60% DC showed no significant difference from sham

    Reported statistics
    • Kruskal-Wallis with post hoc Wilcoxon, p < 0.001, Bonferroni-corrected
    Result

    Part (2), 30% above 6% and 60%, needs the paper's 30% DC recordings, which are not in the dandiset, and the substitutes decide it. With the same rats' 1500 Hz, 200 us recordings (C1) the Kruskal-Wallis is not significant (p = 0.21) and no pair differs; with every such recording (C2) the effect is significant (p = 2.2e-04 Rep1, 3.7e-05 Rep2, 1.9e-04 Rep3) and 30% is above 6% and 60%. Part (4), 6% against 60%, also depends on the 30% group through the Bonferroni family; 6% is below 60% at p = 0.024 alone and at corrected p = 0.071 over three pairs. Part (3) needs the sham. The C1 substitutes (BH506, BH526) were made three to five months before the same rats' DC recordings; C2 adds recordings from August 2023 to 6 March 2024, among them BH498's of 5 and 6 March, three to four days before the DC recordings of 9 March.

    Deviations from the paper’s method
    • The 30% group is a substitute (C1 or C2) or absent (C0), as for fig7a.

Not tested in a notebook 2

1 data missing from the dataset, 1 methods underspecified

Blocked2

  • Blocked

    In the five rats recorded awake and anesthetized in the same week, time-locked responses to the low PRF and 1500 Hz differ significantly in both states, with a reduced response under anesthesia.

    The second batch of five rats recorded awake and anesthetized in the same week, with a sham, is not in the…

    Data missing from the datasetResults 3.2, paragraph 3; Figure 6A to 6Dfig6ad-time-adjacent-batch
    From the paper

    In analysis of the time locked responses, we observed significant differences in response to 300 Hz PRF and 1500 Hz PRF stimulation in both awake and anesthetized conditions ... but with a reduced response under anesthesia

    Reported statistics
    • Kruskal-Wallis with post hoc Wilcoxon, p < 0.05, Bonferroni-corrected
    Result

    The second batch of five rats recorded awake and anesthetized in the same week, with a sham, is not in the dandiset. Its ten subject folders hold eight rats named in the identifiers, all of which have recordings of the first batch's series, and no file is from a two-PRF or sham protocol. The session dates show no rat recorded awake and anesthetized within a week at two PRFs only; BH498's awake recordings (5 and 6 March 2024) precede its anesthetized ones (10 March) by four to five days, but at all five PRFs and without a sham.

  • Blocked

    The off-target sham at 1500 Hz PRF produced no significant response, so the activation is not attributed to an auditory or skull-conduction confound.

    The criterion blocks the claim, as the paper names no test of the sham against baseline.

    Methods underspecifiedDiscussion, paragraph beginning 'One potential confound'; Methods 2.3sham-no-auditory-response
    From the paper

    In this study we additionally performed a sham condition delivering ultrasound off target to the front of the skull, and did not observe any significant response.

    Result

    The criterion blocks the claim, as the paper names no test of the sham against baseline. The dandiset also holds no sham recording, so the sham's responses cannot be shown either.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Methods not availableWere the repeat recordings (BH498, BH506, BH508) part of the paper's analysis, and if not, which recording of each pair was? Methods 2.3 describes one recording per parameter set per rat. The FSU part of delayed-anesthesia-factor depends on it (p = 0.0012 to 0.0015 with one recording per condition, 0.038 to 0.041 with all), and fig6ef-rsu-ispta-rise-then-fall depends on which recording of a pair is kept. This attempt assumed one recording per rat and condition.#
  • Methods not availableWas a response window that does not fall on the 35.7 ms bin edges (0 to 67 ms, 0.2 to 0.7 s) measured from exact spike times or from the PSTH bins that overlap it? The two give different results for fig6ef-rsu-ispta-rise-then-fall, which is blocked until this is known.#
  • Methods not availableFor the delayed-response latency, is the first bin allowed after the 67 ms of ultrasound the first bin starting at or after 67 ms, or the first ending after it? The two give different results for fig4h-awake-latency-wider, which is blocked until this is known.#

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Cell-type specific responses to tFUS in awake and anesthetized rat S1 (Ramachandran et al. 2025)

Tests the findings of Ramachandran, Gao, Yttri, Yu and He (2025) on dandiset 000945, which holds sorted units and trial times of awake and anesthetized rat somatosensory cortex recordings during transcranial focused ultrasound at five pulse repetition frequencies and three duty cycles. It compares time-locked and delayed responses of regular and fast spiking units across parameters and states, and the onset latency of delayed responses. The sham condition and the second batch of rats are not in the dandiset. All files

Environment: Python 3.13, 107 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-10-31
    Agreed with 17 of 22 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The handover of the first run, the executed notebook with the conclusions and summary removed, the helper module and the claims file, with the paper under paper/. The verifier also checked the archive's asset list.
    • fig3-cell-type-sorting: the verifier’s outcome was “Blocked”. The files hold no waveforms, so the k-means features and the cluster separation the criterion requires cannot be computed. Using the deposited labels, 2 of 59 recordings fall within the count tolerances; this is weak evidence, since recording totals run from 31 to 127 units. One of the two, BH508_4500_200_2, is a 12-month repeat that Rep2 would drop, and no base rate is given for a match among 59 recordings.
    • fig4h-awake-latency-wider: the verifier’s outcome was “Blocked”. Awake SD > anesthetized SD under D1 but not under D2, and the claims header blocks a claim when its readings disagree. Every SD is about 0.37 to 0.41 s, with no contrast like the paper's 0.14 vs 0.08. The notebook overrides the claims file's rule for disagreeing readings.
    • fig6ef-rsu-ispta-rise-then-fall: the verifier’s outcome was “Blocked”. The delayed window fails under every reading; 30 Hz (106.6) is above 300 Hz (101.2). The time-locked window holds under W2 but fails under W1 Rep2 by 0.1% (98.2 vs 98.1), so the window readings disagree. At best it is partial.
    • fig7c-rsu-delayed-dc: the verifier’s outcome was “Blocked”. The paper's own 30% DC recordings are not in the dandiset. The substitute 30% condition decides the outcome; C1 is not reproduced (KW p = 0.21) and C2 is partial. Part (4), 6% vs 60%, fails under every reading (corrected p = 0.071). The notebook adopts C1 by its own choice, where the honest outcome for 30%-dependent parts is data_missing.
    • fig7d-fsu-delayed-dc: the verifier’s outcome was “Partially reproduced”. Parts (1) and (2) hold under every reading (6% vs 60% corrected p = 0.015). Part (3), the sham comparison, cannot be tested, and a criterion with an untested part should not reach "reproduced"; the header only covers a missing anesthetized sham. The effect is tiny, 98.2% vs 99.6%, both below baseline.
  • Round 2
    2026-10-31
    Agreed with 20 of 22 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The full executed notebook of the first revision, with its conclusions and summary, the helper module, the claims file and the attempt record, with the paper under paper/.
    • fig5e-rsu-delayed-prf-awake: the verifier’s outcome was “Blocked”. The criterion gives partially reproduced when (1) and (3) hold without (2). Part (1) holds, part (2) fails and part (3), every PRF above sham, is untested, so if a sham held the outcome would be partial. Elsewhere the notebook settles a claim only when the missing parts cannot change its outcome, and fig4-rsu, whose best outcome is also partial, is blocked as data_missing. fig5e should be blocked as data_missing too, or the record should explain why not. The verifier agreed with not reproduced in round 1, and calls that its error.
    • fig7a-rsu-time-locked-dc: the verifier’s outcome was “Blocked”. Partial needs (1) and at least one of (2) to (4). Part (2) fails. Part (1), the Kruskal-Wallis over 6, 30 and 60%, and part (4), 6% below 30%, need the missing 30% group, and part (3) needs the sham, so all three are untested. The conclusion "whatever those parts would show, the claim cannot be reproduced" rules out reproduced, not partial. Cell 13's own rule, that a claim whose outcome depends on a 30% part is blocked as data_missing, applied consistently blocks fig7a. The verifier agreed with not reproduced in round 1, and calls that its error.
  • Round 3
    2026-10-31
    Agreed with 2 of 2 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The two outcome changes proposed after round 2 (fig5e-rsu-delayed-prf-awake and fig7a-rsu-time-locked-dc) and the notebook analysis behind them, with the claims file and the attempt record.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • The 30% group is a substitute (C1 or C2) or absent (C0), as for fig7a.fig7a-60-highest-time-locked-mean fig7b-fsu-time-locked-dc fig7c-rsu-delayed-dc
  • Cell types are the dataset's labels (K0); that they are the paper's k-means output is assumed, and is consistent with the baseline rates without being shown.fig3-cell-type-sorting
  • The other claims depend on this one for cell types. They use the K0 labels, as the claims file's header provides when the dataset carries labels, and do not need the waveform features whose absence blocks this claim, so they are tested.fig3-cell-type-sorting
  • The anesthetized FSU come from two labelled rats where the paper had ten; batch 2 is not in the dandiset.fig4hi-fsu-delayed-latency
  • T2 (505 trials) cannot be run; the files hold 500 trials, or fewer in five recordings.fig4hi-fsu-delayed-latency
  • No sham recording exists; parts (5) and (6) are reported as not tested, and a claim with an untested part is not judged reproduced.fig5a-rsu-time-locked-prf-awake
  • Ten awake recordings repeat a condition in the same rat; results are given with them (Rep1), without the `_2` recordings (Rep2) and with the earliest recording of each pair (Rep3).fig5a-rsu-time-locked-prf-awake
  • Two labelled rats (BH498 at five PRFs, BH512 without 30 Hz) where the paper had ten; BH521's anesthetized recordings have no labels.fig5c-rsu-time-locked-prf-anesth
  • Parts (5) and (6) need the sham and were not tested.fig5c-rsu-time-locked-prf-anesth
  • Anesthetized units from two rats; awake units from seven.rsu-time-locked-anesthesia-factor
  • Two labelled rats where the paper had ten.fig5gh-delayed-prf-anesth
  • Assumed that the paper's analysis used one recording per rat and condition. The paper mentions no repeats, Methods 2.3 fits one recording per parameter set per rat without stating it ("Recordings for a single rat for each set of parameters were completed on the same day" says when a rat's recordings were made, so it supports the assumption only weakly), and the dandiset's description says "Some subjects have duplicate recordings taken a few months after the original ones". Which recording of a pair is the original is open, as three `_2` recordings are earlier than their pair; both choices (Rep2, Rep3) give the same outcome.delayed-anesthesia-factor
  • Anesthetized units from two rats.delayed-anesthesia-factor
  • The dandiset has no 30% DC recording of its own. The substitutes (C1, the PRF series' 1500 Hz, 200 us recordings of BH506 and BH526; C2, those of every rat, with each repeat reading) and C0, no 30% group, are shown; a part that needs the 30% group is treated as data missing.fig7a-rsu-time-locked-dc
  • The 6% and 60% recordings come from three rats where the paper had ten.fig7a-rsu-time-locked-dc
  • No sham recording; part (3) is reported as not tested.fig7d-fsu-delayed-dc
  • The 30% group is a substitute (C1 or C2) or absent (C0); it enters only the Kruskal-Wallis.fig7d-fsu-delayed-dc

Provenance

Attempt record
ramachandran-2025-01
Paper
Parameter-dependent cell-type specific effects of transcranial focused ultrasound stimulation in an awake head-fixed rodent model
Date
2026-10-31
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:000945 (on DANDI)
Version
0.250213.2212 (doi:10.48324/dandi.000945/0.250213.2212)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 1 finding reproduced, Ramachandran et al. 2025

It counts the paper’s findings reproduced in full in a current attempt, verified or not. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/ramachandran-2025/"><img src="https://encorescience.org/badge/papers/ramachandran-2025-reproduced.svg" alt="Encore: 1 finding reproduced, Ramachandran et al. 2025"></a>

Or as Markdown:

[![Encore: 1 finding reproduced, Ramachandran et al. 2025](https://encorescience.org/badge/papers/ramachandran-2025-reproduced.svg)](https://encorescience.org/papers/ramachandran-2025/)

The same numbers are in this page’s JSON, under badge (how it is counted).