Papers / Powell et al. 2021

Coupling between fast and slow oscillator circuits in Cancer borealis is temperature-compensated

Outcomes of 22 claims

  • 10 reproduced
  • 4 partially reproduced
  • 4 not reproduced
  • 4 blocked

Summary: Most of the paper's findings on evoked rhythms hold in this data: gastric mill and pyloric periods shorten with temperature in all 10 preparations, their Q10s do not differ, and LG stays integer-coupled to PD from 7 to 21 C while DG does not. Two did not reproduce: a Q10 of about 2 in most preparations (1 of 10 by the Methods' formula; the paper's count follows its code's per-burst Q10), and a drop in LG spiking near the PD burst end at higher temperatures. LG phase locking held in part. The spontaneous rhythms from 11 to 30 C and the rhythm without the pyloric pacemaker could not be tested, as those recordings are not in the deposit.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Powell et al. (2021) from Zenodo record 3924718 18 Open in Colab

Reproduced10

  • Reproduced

    Gastric mill rhythms could be evoked by dpon stimulation across 7 to 21 C in 9 of 10 preparations.

    Under reading (a) (at least one LG burst period in a bin), 9 of 10 preparations have an LG rhythm at every bin…

    Results, Gastric mill rhythms speed up with increased temperature, paragraph 1; Figure 3verifier disagreed at firstrests on an assumptionfig3-evoked-7-to-21-in-9-of-10
    From the paper

    We were able to evoke gastric rhythms across a temperature range of 7 to 21°C in 9 of 10 preparations

    Result

    Under reading (a) (at least one LG burst period in a bin), 9 of 10 preparations have an LG rhythm at every bin from 7 to 21 C they were held at, under both burst rules, as the criterion is worded (every bin the preparation was held at). The one that fails is 901_086, which spent 330 s in the 21 C bin, with 70 s of stimulation there, and has no LG spike in it; its warmest LG burst start is at 19.1 C. 901_062 never reaches 21 C: its last stimulation is at 19.0 C, followed by 113 LG bursts and cooling back to about 7 C, so 21 C was never tried; it passes because it has a rhythm at every step it had (7, 11, 15 and 19 C), which fits the Methods' 'in some preparations, 19 C was the warmest temperature that a gastric mill rhythm could be evoked'. If 21 C must also be reached, 8 of 10 pass, which would not be reproduced. Under reading (b) (at least 30 significands) 2 of 10. All ten preparations are in the record (10 of 10 evoked). Counting every bin the temperature passed through gives 3 (reading a) and 1 (reading b) of 10, because the 9, 13 and 17 C bins crossed on ramps (20 to 270 s) have few or no LG bursts, so the outcome rests on the 120 s reading of held.

    Deviations from the paper’s method
    • The claims file leaves open which bins a preparation 'was held at'. A bin counts as held when the recording spends at least 120 s in it, the 2-minute minimum step of the Methods ('a given temperature step was held for at least 2 minutes') and the code's (BurstPeriodsVsTime.m, 'temperature held for less than 2 minutes'). Counting every bin with any time in it gives 3 of 10, so the outcome rests on this choice, which is an assumption (assumed: true); the question is put to the paper's authors as a methods_unavailable finding.
    • A preparation whose warmest held bin is 19 C (901_062) passes when it has a rhythm at every bin it was held at, as the criterion is worded; the count requiring 21 C as well (8 of 10) is shown beside it.
  • Reproduced

    Both LG (gastric mill) and PD (pyloric) burst periods decrease with increasing temperature, a coordinated decrease seen in all 10 preparations.

    In all 10 preparations the mean PD and LG periods in the warmest bin are below those in the coldest (PD 0.77…

    Results, Gastric mill and pyloric cycle periods are similarly temperature-sensitive, paragraphs 1 and 2; Figure 4a and 4bfig4b-periods-decrease-all-preps
    From the paper

    A coordinated decrease in both gastric mill and pyloric cycle periods was observed in all 10 preparations ( Figure 4b )

    Result

    In all 10 preparations the mean PD and LG periods in the warmest bin are below those in the coldest (PD 0.77 to 2.00 s at 7 C against 0.28 to 0.56 s at the warmest; LG 12.5 to 40.2 s against 5.0 to 12.6 s), and the Spearman correlation of bin means with temperature is negative for both (PD -0.976 to -1, LG -0.643 to -1). The same holds under the code's burst rule.

  • Reproduced

    The apparent Q10s of the pyloric (PD) and gastric mill (LG) burst frequencies do not differ (paired t-test, p = 0.235, N = 10, t = 1.27).

    Paired t-test on the Methods' Q10s (every bin), t = -1.418, p = 0.190, n = 10, mean PD minus LG -5.35 (driven…

    Results, Gastric mill and pyloric cycle periods are similarly temperature-sensitive, paragraph 2; Figure 4c legendfig4c-q10-pd-lg-not-different
    From the paper

    Estimated Q 10 s were not significantly different for LG and PD burst periods (paired t-test, p = 0.235 , N = 10 , t = 1.27 )

    Reported statistics
    • paired t-test, t = 1.27, p = 0.235 (n = 10 preparations)
    Result

    Paired t-test on the Methods' Q10s (every bin), t = -1.418, p = 0.190, n = 10, mean PD minus LG -5.35 (driven by the two large LG Q10s); held steps only, t = -0.739, p = 0.479. The code's per-burst Q10 gives t = 1.204, p = 0.259 with the Methods burst rule and t = 1.272, p = 0.235 with the code's, the paper's values. No version reaches p < 0.05.

  • Reproduced

    The evoked gastric mill rhythm slows down (LG burst period lengthens) with time since stimulation.

    64 stretches from 10 preparations. The slope of the mean LG period on time is positive at 8 of 9 temperatures…

    Results, Gastric mill and pyloric cycle periods are similarly temperature-sensitive, paragraph 1; Figure 4, figure supplement 1fig4s1-slowdown-after-stimulation
    From the paper

    despite significant variability in the LG burst period, due to a slowing down ( Figure 4—figure supplement 1 ) of the gastric mill rhythm with time since stimulation

    Result

    64 stretches from 10 preparations. The slope of the mean LG period on time is positive at 8 of 9 temperatures under both burst rules (code's 7 ISIs and the Methods' 5 spikes), negative only at 13 C (-0.0006 s per s, two stretches). At 7, 11, 15, 19 and 21 C (8 to 17 stretches) the slopes are 0.0055 to 0.0171 s per s, r 0.63 to 0.87, and the mean period rises from 6.7 to 15.4 s in the first minute to 10.1 to 19.6 s at 9 to 10 minutes. No stretch has an even rounded temperature, so the odd-bin filter drops none.

    Deviations from the paper’s method
    • A stimulation block is taken as running to the end of the recording when no stimulation follows, as MATLAB's temperature(stim:[]) is empty in BurstPeriodsVsTime.m; the mask's meaning (stimulation where 0) is taken from the code (findStimulationTimes.m, BurstPeriodsVsTime.m), as the record does not describe it.
  • Reproduced

    In the example preparation the ratio of LG to PD period is close to an integer at both temperatures, about 10 at 7 C and about 11 at 23 C, and PD bursts end shortly before LG bursts start.

    Reading (a), the LG cycle closest to the labelled T_LG; at 7 C (file 0006, 6.92 C) T_LG 9.244 s, mean T_PD…

    Results, Integer coupling is maintained across a physiological temperature range, paragraph 2; Figure 5afig5a-example-ratios
    From the paper

    The ratio of LG to PD periods was close to an integer at both temperatures (~10 at 7°C and ~11 at 23°C)

    Result

    Reading (a), the LG cycle closest to the labelled T_LG; at 7 C (file 0006, 6.92 C) T_LG 9.244 s, mean T_PD 0.843 s, ratio 10.961 (0.04 from an integer); at 23 C (file 0079, 23.07 C) T_LG 3.438 s, mean T_PD 0.316 s, ratio 10.873 (0.13 from an integer). A second 7 C cycle with T_LG 9.245 s has mean T_PD 0.923 s and ratio 10.016, closer to the label's 0.911 s and 10.06. Reading (b), the median ratio of the file, gives 10.76 and 14.02 and misses. LG bursts start a median 0.17 s (7 C) and 0.13 s (23 C) after the last PD burst end; this part of the statement is shown, not judged.

  • Reproduced

    LG and PD burst periods are significantly integer-coupled at every temperature from 7 to 21 C (two-sample Kolmogorov-Smirnov test against shuffled periods, p < 1e-5, D > 0.24).

    With the code's shuffle (100 draws, reading a) every bin from 7 to 21 C has median p below 0.05/9 (1.5e-8 to…

    Results, Integer coupling is maintained across a physiological temperature range, paragraph 4; Figure 5b, 5d and 5equestion to the readerfig5d-lg-pd-integer-coupled
    From the paper

    LG and PD were significantly integer-coupled, at temperatures from 7°C to 21°C (p < 10 –5 , D > 0.24)

    Reported statistics
    • two-sample Kolmogorov-Smirnoff test, observed against shuffled significands, per temperature, D > 0.24, p < 10⁻⁵, Bonferroni over 9 temperature steps (threshold 0.05/9 = 0.0056)-corrected (n = LG bursts pooled across all 10 preparations at each temperature)
    Result

    With the code's shuffle (100 draws, reading a) every bin from 7 to 21 C has median p below 0.05/9 (1.5e-8 to 4.9e-4) and median D above 0.216 (0.223 at 21 C to 0.351), Methods burst rule. D at 21 C under the five seeds is 0.2233, 0.2239, 0.2207, 0.2221 and 0.2214, all above the bound, so the outcome does not depend on the seed. The reported p < 1e-5 is not met at 17 and 21 C with the code's draws (median p 2.6e-5 and 4.9e-4). With the permutation shuffle (reading b) every bin from 7 to 21 C has p below 1e-5 but D at 21 C is 0.199. 23 C is not significant (D 0.162, p 0.31). The code's burst rule gives the same results within 0.01 in D. The criterion's reproduced clause (p < 0.05/9, D > 0.216) is applied; whether the reported p < 1e-5 should decide instead, under which no reading meets both bounds, is asked of a reader (questions/powell-2021.yaml).

    Deviations from the paper’s method
    • The paper used one shuffle draw per temperature; here the median D and p over 1000 draws are reported, as the criterion sets. p is the asymptotic p of MATLAB's kstest2.
  • Reproduced

    DG and PD burst periods are not significantly integer-coupled at any temperature (p > 0.02, D < 0.16).

    With the code's shuffle no bin reaches p < 0.05/9 (median p 0.082 to 0.925, D 0.115 to 0.160, Methods burst…

    Results, Integer coupling is maintained across a physiological temperature range, paragraph 4; Figure 5c, 5d and 5efig5d-dg-pd-not-coupled
    From the paper

    while DG and PD were not significantly coupled at any temperature (p > 0.02, D < 0.16)

    Reported statistics
    • two-sample Kolmogorov-Smirnoff test, observed against shuffled significands, per temperature, D < 0.16, p > 0.02, Bonferroni over 9 temperature steps (threshold 0.05/9 = 0.0056)-corrected
    Result

    With the code's shuffle no bin reaches p < 0.05/9 (median p 0.082 to 0.925, D 0.115 to 0.160, Methods burst rule); the smallest p over bins is 0.078 to 0.084 under the five seeds. D is below 0.16 except at 23 C (12 DG cycles, D 0.160, or 0.19 with the code's burst rule). With the permutation shuffle (variant) the 11 and 15 C bins are significant (p 5.1e-4 and 5.8e-4, D 0.084 and 0.104), so the absence rests on the code's shuffle, which the criterion names. 901_005 has no DG spikes, so nine preparations enter.

  • Reproduced

    The ratio of LG to PD cycle period does not change with temperature (Spearman test, p = 0.88, n = 3799).

    Spearman over all cycles, rho = 0.016, p = 0.311, n = 3850 (Methods burst rule); with the code's burst rule…

    Results, Integer coupling is maintained across a physiological temperature range, paragraph 4; Figure 5ffig5f-ratio-independent-of-temperature
    From the paper

    Ratios of LG to PD cycle period were spread across a similar range of temperatures, even at higher temperatures when integer coupling was less pronounced (p = 0.88, n = 3799 , PD cycles pooled across all preparations, Spearman test)

    Reported statistics
    • Spearman test, p = 0.88 (n = 3799 cycles pooled across all preparations)
    Result

    Spearman over all cycles, rho = 0.016, p = 0.311, n = 3850 (Methods burst rule); with the code's burst rule rho = 0.002, p = 0.880, n = 3799, the paper's numbers. Prep-by-prep means per bin, rho = 0.21, p = 0.10 (64 means).

  • Reproduced

    DG bursts are not phase-locked to PD; DG burst starts are not sharply peaked in PD phase, not significantly non-uniform in every preparation and temperature, and the effect is much smaller than for LG (p from 0.001 to 0.85, 0.15 < z < 13).

    Methods sample (first 40), 35 DG combinations; 16 with p >= 0.05, median z 3.38 against 22.59 for LG (Methods…

    Results, LG preserves phase locking to PD across physiological temperatures, paragraph 4; Figure 6d and 6efig6e-dg-not-phase-locked
    From the paper

    DG burst starts are not sharply peaked in PD phase, and they are not significantly different from a uniform distribution for all preparations at all temperatures ( Figure 6e , p ∈ [0.001, 0.85], 0.15 < z < 13, Rayleigh test)

    Reported statistics
    • Rayleigh test for non-uniformity, per preparation and temperature, 0.15 < z < 13, p > 0.001
    Result

    Methods sample (first 40), 35 DG combinations; 16 with p >= 0.05, median z 3.38 against 22.59 for LG (Methods burst rule). DG p 1.4e-8 to 0.82 and z 0.21 to 16.25, beyond the reported 0.001 to 0.85 and 0.15 to 13 at the significant end; with the first 50, z 0.16 to 12.27 (Methods burst rule) or 13.65 (code's), p from 2.3e-6 to 0.85.

  • Reproduced

    DG spike probability does not show a noticeable decrease close to the end of PD bursting.

    At the eight temperatures with at least 1000 DG spikes (7 to 21 C) the DG p.d.f. at the PD burst-end bin is…

    Results, LG preserves phase locking to PD across physiological temperatures, paragraph 4; Figure 6ffig6f-dg-spiking-no-drop
    From the paper

    DG spike probability also does not show a noticeable decrease close to the end of PD bursting

    Result

    At the eight temperatures with at least 1000 DG spikes (7 to 21 C) the DG p.d.f. at the PD burst-end bin is 0.888 to 1.089, above 1 minus half the LG drop at every one (thresholds 0.725 to 0.906). The same holds under the code's burst rule (0.912 to 1.089). The odd-temperature filter leaves out 9.2% of DG spikes with a PD phase (even rounded temperatures).

Partially reproduced4

  • Partially reproduced

    The area between the significand c.d.f. and the diagonal, a measure of integer coupling, is larger for LG/PD than for DG/PD at every temperature, and the DG/PD areas overlap those of shuffled periods.

    The LG area exceeds the DG area in all 8 bins where both exist (LG 0.127 to 0.193, DG 0.050 to 0.079) under…

    Results, Integer coupling is maintained across a physiological temperature range, paragraph 4; Figure 5efig5e-lg-area-exceeds-dg
    From the paper

    Areas for LG/PD significands were larger than areas for DG/PD significands at every temperature ( Figure 5e ), suggesting greater integer coupling. Areas for DG/PD significands overlapped with areas computed after shuffling

    Result

    The LG area exceeds the DG area in all 8 bins where both exist (LG 0.127 to 0.193, DG 0.050 to 0.079) under all five seeds. The DG area (mean plus or minus SEM over preparations) overlaps the shuffled area in 1 of 8 bins under the claim's seed (7 C) and 1, 4, 2, 2 and 1 of 8 under the five seeds, never in most; in every other bin the DG area lies above the shuffled one. Against the shuffle of the LG call (the other gray line), DG overlaps in 3 of 8. With the code's burst rule, 2 of 7. Over the six bins with more than one DG preparation (where the SEM is defined), DG overlaps in 1 of 6 under the claim's seed and 1, 4, 2, 2 and 1 of 6 under the five seeds. With the shuffled pool built from independent draws in place of one permutation, 3, 2, 3, 3 and 3 of 8.

    Deviations from the paper’s method
    • Bins with a single preparation have no SEM; their interval is taken as the value itself (the code draws them without an error bar).
  • Partially reproduced

    LG burst starts are phase-locked to the PD cycle, their distribution in PD phase sharply peaked and significantly non-uniform (Rayleigh test, p < 4e-4, 7.5 < z < 45).

    Methods sample (a), first 40 starts, 41 preparation and temperature combinations; all p < 0.05 (largest…

    Results, LG preserves phase locking to PD across physiological temperatures, paragraph 2; Figure 6a and 6bquestion to the readerfig6b-lg-phase-locked
    From the paper

    LG burst start probabilities were sharply peaked ( Figure 6b ) and were significantly different from a uniform distribution ( Figure 6b , dashed line, p < 4×10 –4 , 7.5<z<45, Rayleigh test for non-uniformity; see Methods for details)

    Reported statistics
    • Rayleigh test for non-uniformity, per preparation and temperature, 7.5 < z < 45, p < 4 × 10⁻⁴
    Result

    Methods sample (a), first 40 starts, 41 preparation and temperature combinations; all p < 0.05 (largest 0.008), 4 combinations not below 4.4e-4, z 4.74 to 35.77 (Methods burst rule). With the code's burst rule one combination has p = 0.082. The later code's sample (b), first 50, gives p up to 2.1e-4 and z 8.20 to 45.31 (Methods burst rule, within the bounds) and p up to 4.5e-4 and z 7.49 to 45.44 (code's burst rule), the reported p < 4e-4 and 7.5 < z < 45 within rounding. The archived code's pooled sample (c) gives z 67 to 577. Burst starts at even rounded temperatures (220 of 4128 LG starts with a PD phase) belong to no bin and are not tested. Whether the first-50 sample, which matches the reported ranges, should be the main reading is asked of a reader (questions/powell-2021.yaml).

    Deviations from the paper’s method
    • The reported ranges match the sample of the later code (commit 7a82b1f, first 50 starts), not the Methods' first 40, as the claims file anticipated; the outcome follows the Methods, as the criterion sets.
  • Partially reproduced

    A total of 3816 LG burst starts and 3228 DG burst starts across nine temperature points and 10 preparations enter the phase distributions, and about 35% of preparation and temperature combinations have fewer than 40 burst starts.

    Partially reproduced: two of the three quantities are within tolerance.

    Materials and methods, Analysis of distribution of LG/DG burst starts in PD phase, paragraph 2verifier disagreed at firstquestion to the readerfig6b-lg-start-counts
    From the paper

    Preparation and temperature combinations where there were <40 burst starts (~35% of data) were excluded. A total of n = 3816 LG burst starts and n = 3228 DG burst starts across nine temperature points and 10 preparations are plotted in Figure 6b,d

    Result

    Partially reproduced: two of the three quantities are within tolerance. Methods burst rule, all starts with a defined PD phase in the bins 7 to 23 C; LG 3908 (within 3816 plus or minus 381.6), DG 3573 (above 3228 plus or minus 322.8 by 22). Fraction of combinations with fewer than 40 starts, reading (a), over combinations with any start, 0.339 (LG), 0.386 (DG), 0.361 (both); over all 90 per neuron 0.54 to 0.61; reading (b), of starts, 0.086 to 0.100. With the code's burst rule the totals are LG 3865 and DG 3448, both within tolerance, and with the code's burst rule and the archived code's sample (temperatures with at least 100 pooled starts) LG 3816, the paper's number, and DG 3220. Starts at even rounded temperatures, in none of the nine temperature points, are not counted (220 LG and 218 DG). Whether the code's burst rule, with which the paper's counts match, should decide is asked of a reader (questions/powell-2021.yaml).

    Deviations from the paper’s method
    • The claims file's reading (a) does not say over which combinations the fraction is taken; both those with any start and all 90 are shown. The outcome is decided by the DG total, whichever is used.
  • Partially reproduced

    From 7 to 21 C, LG bursts start at a phase of about 0.5 in the PD cycle, and this phase does not trend with temperature (Spearman test, p = 0.46, rho = -0.31).

    No trend from 7 to 21 C; all starts, rho = -0.190, p = 0.651; first 40, rho = -0.429, p = 0.289 (Methods burst…

    Results, LG preserves phase locking to PD across physiological temperatures, paragraph 2; Figure 6b insetfig6b-lg-phase-constant
    From the paper

    From 7°C to 21°C, LG bursts started at a phase of ~0.5 in the PD cycle ( Figure 6b , inset), and this phase offset did not significantly trend across this temperature range (p = 0.46, ρ = –0.31, Spearman test)

    Reported statistics
    • Spearman test, rho = -0.31, p = 0.46 (n = 8 temperature steps (7 to 21 C), means across preparations)
    Result

    No trend from 7 to 21 C; all starts, rho = -0.190, p = 0.651; first 40, rho = -0.429, p = 0.289 (Methods burst rule). With the code's burst rule and all starts, rho = -0.310, p = 0.456, the paper's values. The bin means (all starts) are 0.416 to 0.494, mean 0.45, with 7, 9, 17 and 21 C below 0.45; first 40, 0.337 to 0.504. The phase part fails under both samples, the trend part holds under both.

Not reproduced4

  • Not reproduced

    In 4 of 10 evoked preparations a spontaneous gastric mill rhythm was seen at 11 C before stimulation; in three of these four the spontaneous and evoked rhythms were similar in LG spike and burst timing and in cycle period.

    Tested on three of the four preparations of fig_within_prep_spont_evoked_comparison.m; 941_006 has no spike…

    Results, Gastric mill rhythms speed up with increased temperature, paragraph 2; Figure 3, figure supplement 1fig3s1-spontaneous-and-evoked-similar
    From the paper

    Three of the four preparations that had spontaneous and evoked rhythms shared similarities in LG spike and burst timing ( Figure 3—figure supplement 1b ) and rhythm cycle period (mean ± SD; Figure 3—figure supplement 1c )

    Result

    Tested on three of the four preparations of fig_within_prep_spont_evoked_comparison.m; 941_006 has no spike times in the record (941_006.zip holds raw ABF files and crabsort classifier files only). Spontaneous stretch file 0000, evoked files 0032, 0012 and 0020 as the script selects. Methods burst rule, LG period mean plus or minus SD; 901_086 24.0 +- 0.7 s (two periods) against 11.2 +- 2.9 s, 901_080 16.1 +- 6.9 s against 15.6 +- 2.9 s, 901_062 16.6 +- 5.7 s against 7.5 +- 0.8 s. Only 901_080 is similar under either reading, so the four can give at most two similar whatever 941_006 shows, and the criterion (three of four) fails. The code's burst rule gives the same. The script's own call (computePeriods with its default of 1 ISI, bursts of at least 2 spikes) gives 901_062 9.9 +- 3.5 s, similar under reading (b), which would leave three of four possible; that is a variant. Among the ten evoked preparations, 3 (901_062, 901_080, 901_086) have LG burst periods before their first stimulation in the 11 C bin (13 to 43 periods), not 4; 932_151 has 16 before stimulation at 9.83 to 9.93 C, just outside the bin, so with it 4 of 10 have pre-stimulation bursting; the fourth preparation of the paper's script is 941_006, which is not one of the ten. The first measured value is that count, the second the similar preparations of the three tested. Taking every pre-stimulation LG period at 11 C as the spontaneous stretch gives 21.7 +- 5.3, 17.5 +- 7.8 and 16.2 +- 4.9 s, the same picture. The evoked file the script selects for 901_080 (0012) is at 7.25 C, against 10.86 C for its spontaneous file; the comparison follows the script. The ISIs are shown and not judged, as the criterion sets.

    Deviations from the paper’s method
    • 941_006 has no spike times in the record, so three of the four preparations are tested; the outcome does not depend on it under the Methods burst rule, since one similar of three allows at most two of four.
    • The spike times of a raw file are those within its samples in evoked_data.mat (the filename categorical), the stacked form of the same crabsort annotations the script reads per file.
  • Not reproduced

    Most preparations (8 of 10) had a cycle period Q10 of about 2 for both the pyloric and the gastric mill rhythm.

    Under the Methods' Q10 over every bin, 1 of 10 preparations has both Q10s within 1.8 to 2.2 and 2 of 10 within…

    Results, Gastric mill and pyloric cycle periods are similarly temperature-sensitive, paragraph 2; Figure 4cquestion to the readerfig4c-q10-about-2
    From the paper

    Figure 4c shows that most preparations (8 of 10) exhibited a cycle period Q 10 of ~2 for both the pyloric and gastric mill rhythms

    Result

    Under the Methods' Q10 over every bin, 1 of 10 preparations has both Q10s within 1.8 to 2.2 and 2 of 10 within 1.5 to 2.5; over the held steps only, 1 and 3 of 10. Per-preparation LG Q10s reach 16.6 and 39.0 when every bin is used, from bins at 9 and 13 C crossed during ramps (per-bin LG Q10s up to 98.7 and 180.8). The code's per-burst Q10 (variant) gives 3 of 10 within 1.8 to 2.2 and 8 of 10 within 1.5 to 2.5 (Methods burst rule; 1 and 8 with the code's), so the paper's count matches the code's computation under the wider reading of "~2". With T and T_11 the mean measured temperatures of the bursts in each bin in place of the bin centres (the verifier's point), the counts are the same (1 and 2 of 10 over every bin, 1 and 3 over the held steps). The per-preparation LG Q10s from every bin then reach 705 (901_052) and 70 (901_086), from the 9 C bin of each, which holds one LG burst, at 9.81 C against 10.89 C at 11 C (per-bin Q10 4919) and at 9.24 C against 11.03 C (335). Whether the code's Q10, which the paper's own t-test matches exactly, should be the main analysis is asked of a reader (questions/powell-2021.yaml).

    Deviations from the paper’s method
    • The claims file does not say which temperatures enter the Methods' Q10. Two readings were run, every bin with bursts and only the bins held at least 120 s (the temperature steps of the Methods, "Spontaneous and evoked gastric mill rhythm temperature ranges"); both give the same outcome. T is the bin centre, f_T the mean of 1/period over bursts starting in the bin.
    • PD periods above 5 s and LG periods above 50 s are removed before the Q10, as fig_burst_period.m does (the outlier filter the claims file cites for fig4b-periods-decrease-all-preps).
  • Not reproduced

    At low temperatures the ratios of LG to PD cycle period range widely, from about 5 to 25.

    Reading (a), 7 C bin, 283 ratios; 2.5th and 97.5th percentiles 7.04 and 26.03 (minimum 5.76, maximum 39.91…

    Results, Integer coupling is maintained across a physiological temperature range, paragraph 4; Figure 5ffig5f-ratio-range
    From the paper

    At low temperatures, when integer coupling was particularly strong (as seen from the horizontal banding), these ratios were distributed over a wide range from 5 to 25

    Result

    Reading (a), 7 C bin, 283 ratios; 2.5th and 97.5th percentiles 7.04 and 26.03 (minimum 5.76, maximum 39.91, 1st percentile 6.81). Reading (b), 7 to 11 C, 1609 ratios; 7.03 and 25.99 (1st percentile 6.07). Both lie within 4.5 to 27.5 but neither reaches down to 5.5, so the lower end of the bulk is about 7, not 5. The code's burst rule gives the same percentiles within 0.05.

  • Not reproduced

    LG spike probability in the PD cycle shows a pronounced decrease at higher temperatures, occurring close to PD burst termination.

    The LG spike p.d.f. at the mean PD burst-end phase (about 0.19 to 0.22) is below 1 at every temperature with…

    Results, LG preserves phase locking to PD across physiological temperatures, paragraph 3; Figure 6cfig6c-lg-spiking-drops-near-pd-end
    From the paper

    We measured the spike probability of LG conditional on PD phase across this temperature range and found a pronounced decrease in the probability of spiking in LG at higher temperatures ( Figure 6c ). This decrease in LG spike probability occurred close to PD burst termination

    Result

    The LG spike p.d.f. at the mean PD burst-end phase (about 0.19 to 0.22) is below 1 at every temperature with at least 1000 spikes (reading a, 0.45 to 0.81 from 7 to 21 C, 0.23 at 23 C), but its Spearman correlation with temperature is positive (reading a, rho = 0.150, p = 0.70; reading b, 0.167, p = 0.67; without 23 C, 0.64 and 0.67). The value rises from 0.62 at 11 C to 0.81 at 21 C; only the 23 C bin, from the two preparations that reach it, shows a low value. The code's burst rule gives the same picture. The odd-temperature filter leaves out 3.6% of LG spikes with a PD phase (even rounded temperatures).

Not tested in a notebook 4

4 data missing from the dataset

Blocked4

  • Blocked

    Spontaneous gastric mill activity (LG bursting) occurred at temperatures between 11 and 30 C, in nine preparations in total.

    The nine preparations with spontaneous rhythms (crabs of July 2013, recordings of Haddad and Marder 2018) are…

    Data missing from the datasetResults, Spontaneous gastric mill rhythms span a physiological range of temperatures, paragraphs 1 and 3; Figure 2 and Figure 2, figure supplement 1fig2-spontaneous-11-to-30
    From the paper

    We inspected a dataset of extracellular recordings of dgn and lgn during temperature ramps ( Haddad and Marder, 2018 ) and found spontaneous gastric mill activity at temperatures between 11°C and 30°C ... there were a total of nine preparations in which spontaneous rhythms were observed at a variety of different temperatures

    Result

    The nine preparations with spontaneous rhythms (crabs of July 2013, recordings of Haddad and Marder 2018) are not in the record. Its only spike annotations, evoked_data.mat, are the ten evoked preparations of getEvokedData.m, and its zips hold raw files of nine of those ten and of 941_003 and 941_006, recorded in June 2019. The paper's data statement names only this record. A search of Zenodo (queries on Haddad, Marder, Powell, stomatogastric, temperature) and DANDI (stomatogastric) found no deposit of them; Zenodo record 5139650 (Haddad and Marder) holds six ABF files of notebooks 845 and 857 recorded in the decentralized condition, with no spike annotations and not the example preparation 830_116.

  • Blocked

    In the example preparation of Figure 2a, spontaneous gastric mill rhythms were relatively regular at lower temperatures and less regular at higher temperatures.

    The example preparation 830_116_2 belongs to the spontaneous set, which is not in the record (see…

    Data missing from the datasetResults, Spontaneous gastric mill rhythms span a physiological range of temperatures, paragraph 2; Figure 2afig2a-less-regular-at-high-temperature
    From the paper

    While these recordings show relatively regular gastric mill rhythms at lower temperatures, they were less regular at higher temperatures

    Result

    The example preparation 830_116_2 belongs to the spontaneous set, which is not in the record (see fig2-spontaneous-11-to-30).

  • Blocked

    With the pyloric pacemaker suppressed by hyperpolarizing both PD neurons, an evoked gastric mill rhythm persists, and its cycle period decreases with increasing temperature as it does with the pacemaker active.

    The nine preparations with the PD neurons hyperpolarized (2020, including 999_017 of PD_hyp.m) are not in the…

    Data missing from the datasetResults, Gastric mill rhythms can be evoked when the pyloric pacemaker is suppressed, paragraph 2; Figure 4, figure supplement 2cfig4s2-gastric-without-pyloric-pacemaker
    From the paper

    Figure 4—figure supplement 2c shows that the gastric mill rhythm cycle period steadily decreased with increased temperature regardless of pyloric pacemaker activity

    Result

    The nine preparations with the PD neurons hyperpolarized (2020, including 999_017 of PD_hyp.m) are not in the record; no zip or annotation carries a 999 notebook number, and the two preparations not among the evoked ten (941_003, 941_006) were recorded in June 2019.

  • Blocked

    In all nine preparations a gastric mill rhythm was evoked at 11 and 15 C, with the pacemaker active and with AB/PD hyperpolarized; at 19 and 21 C only a subset produced one.

    As fig4s2-gastric-without-pyloric-pacemaker; the PD-hyperpolarized set is not in the record.

    Data missing from the datasetResults, Gastric mill rhythms can be evoked when the pyloric pacemaker is suppressed, paragraph 2; Figure 4, figure supplement 2dfig4s2-rhythm-counts
    From the paper

    Figure 4—figure supplement 2d shows that in all nine preparations, the gastric mill rhythm was activated at 11°C and 15°C, whereas at 19°C and 21°C only a subset of preparations produced gastric mill rhythms at these elevated temperatures

    Result

    As fig4s2-gastric-without-pyloric-pacemaker; the PD-hyperpolarized set is not in the record.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Published code disagreesThe Methods keep bursts of at least n spikes (5 for LG and DG, 2 for PD), but the paper's burst detection, crabsort.computePeriods, compares n with the number of inter-spike intervals in a burst, keeping bursts of at least n + 1 spikes. The paper's reported numbers follow the code's rule (for example 3799 cycles in Figure 5f, against 3850 under the Methods' rule, and 3228 DG burst starts, which the Methods' rule exceeds by more than 10%).#
  • Published code disagreesThe Methods test the first 40 LG and DG burst starts of each preparation and temperature for non-uniformity, but the reported ranges (LG p < 4e-4, 7.5 < z < 45; DG z up to 13) are those of the first 50, the sample of the later code (marderlab/gastric commit 7a82b1f). The archived commit the paper cites (fa07d36) pools all starts of a temperature over preparations, which gives z of 67 to 577. With 40 starts z cannot exceed 40.#
  • Published code disagreesThe Methods compute the Q10 from the mean burst frequency at each temperature against 11 C, but fig_burst_period.m computes a Q10 for every burst at its own temperature, against the bursts within 0.1 C of 11 C, removes Q10s above 10 and averages per preparation. The reported count of 8 of 10 preparations near 2 and the paired t-test (t = 1.27, p = 0.235) follow the code; the Methods' formula gives 1 to 3 of 10 and LG Q10s up to 39 from temperatures crossed during ramps.#
  • Paper inconsistentFigure 3, figure supplement 1 says that 4 of the 10 evoked preparations had spontaneous rhythms, but one of the four preparations its script uses (941_006) is not among the ten evoked preparations and was recorded in June 2019, not 2017. In evoked_data.mat, 3 of the 10 evoked preparations (901_062, 901_080, 901_086) have LG bursting before their first stimulation at 11 C, which with 941_006 makes the four of the script. A fourth of the ten, 932_151, has 16 LG burst periods before stimulation at 9.83 to 9.93 C, so the paper's 4 of 10 may count it in place of 941_006.#
  • Methods not availableThe paper says rhythms were evoked 'across a temperature range of 7 to 21 C in 9 of 10 preparations', with steps of 2 or 4 C 'until a gastric mill rhythm could no longer be evoked'. It does not say whether a preparation whose warmest step was 19 C (901_062, never brought to 21 C) counts among the nine, nor whether temperatures crossed only between steps (9, 13 and 17 C for most preparations) count. The attempt assumed that only bins held at least 2 minutes count and that a preparation passes with a rhythm at every step it had, which gives the paper's 9; requiring 21 C gives 8, and counting every bin crossed gives 3. Which did the authors count?#

Questions about the claims 4

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • openasked 2026-11-25about fig4c-q10-about-2

    The criterion makes the Methods' Q10 (one Q10 per temperature from the mean frequency, averaged per preparation) the main analysis and the code's per-burst Q10 (fig_burst_period.m) a variant. The paper's own statistic for the same Q10s, the paired t-test of fig4c-q10-pd-lg-not-different (t = 1.272, p = 0.235), is matched exactly by the code's per-burst Q10 with the code's burst rule, and by no reading of the Methods' formula. Should the code's Q10 be the main analysis for this claim, since the figure and its count were evidently made with it?

    Passage. Q 10 = f T f 11 10 T - 11 where f T is the mean burst frequency at temperature T and f 11 is the mean burst frequency at 11 C (the reference temperature). (Materials and methods, Estimation and comparison of Q10s); "Figure 4c shows that most preparations (8 of 10) exhibited a cycle period Q 10 of ~2 for both the pyloric and gastric mill rhythms" (Results)

    Why it matters. Under the Methods' Q10, 1 to 3 of 10 preparations have both Q10s near 2, so the claim is not reproduced; under the code's per-burst Q10, 8 of 10 have both within 1.5 to 2.5 (both burst rules), which would reproduce it under reading (b).

    No reader has answered it yet.
  • openasked 2026-11-25about fig6b-lg-start-counts

    The criterion counts burst starts with the Methods' burst rule (at least 5 spikes). The paper's counts are matched by the code's rule (crabsort.computePeriods keeps bursts of at least 5 inter-spike intervals, 6 spikes) and the archived code's sample (temperatures with at least 100 pooled starts), which gives exactly 3816 LG starts. Other reported numbers also follow the code's rule exactly (n = 3799 and p = 0.88 in Figure 5f, rho = -0.31 and p = 0.46 in Figure 6b). Should the code's burst rule be the main reading for this count, or at least a reading the outcome can rest on?

    Passage. Spikes were considered to be part of a burst only if there were at least n spikes per burst, with n = 5 for LG and DG and n = 2 for PD. (Materials and methods, Detection of bursts and measurement of burst metrics); A total of n = 3816 LG burst starts and n = 3228 DG burst starts across nine temperature points and 10 preparations are plotted in Figure 6b,d (Materials and methods, Analysis of distribution of LG/DG burst starts in PD phase)

    Why it matters. Under the Methods' rule the DG total is 3573, 22 above the tolerance, and the claim is not reproduced. Under the code's rule the totals are 3865 LG and 3448 DG, both within tolerance, with the fraction of combinations under 40 starts at 0.34 (LG), so the claim would be reproduced.

    No reader has answered it yet.
  • openasked 2026-11-25about fig6b-lg-phase-locked

    The criterion follows the Methods' sample, the first 40 burst starts per preparation and temperature, and notes that under it z cannot exceed 40, so the reported upper bound of 45 cannot be met. The reported ranges are matched by the later code's sample (first 50 starts, marderlab/gastric commit 7a82b1f) with the code's burst rule, z 7.49 to 45.44, largest p 4.5e-4. Should the first-50 sample, with which the paper's numbers were evidently produced, be the main reading?

    Passage. we analyzed the first 40 burst starts for each preparation at each temperature step. (Materials and methods, Analysis of distribution of LG/DG burst starts in PD phase); "significantly different from a uniform distribution ( Figure 6b , dashed line, p < 4x10-4, 7.5<z<45, Rayleigh test for non-uniformity)" (Results)

    Why it matters. Under the first 40, four combinations miss p < 4.4e-4 and z falls to 4.74, so the claim is partially reproduced. Under the first 50 with the Methods' burst rule every combination is within the widened bounds (p up to 2.1e-4, z 8.20 to 45.31), which would reproduce it.

    No reader has answered it yet.
  • openasked 2026-11-25about fig5d-lg-pd-integer-coupled

    The criterion's "reproduced" clause asks p < 0.05/9 with D > 0.216 in every bin, while its "partially reproduced" clause applies when "some D or p miss the reported bounds", and the reported bound on p is p < 1e-5. Read together, a result with every p below 0.0056 but some p above 1e-5 meets both clauses. Which bound on p decides reproduced, 0.05/9 or 1e-5?

    Passage. LG and PD were significantly integer-coupled, at temperatures from 7 C to 21 C (p < 10-5, D > 0.24) (Results, Integer coupling is maintained across a physiological temperature range)

    Why it matters. With the code's shuffle every bin from 7 to 21 C has p < 0.05/9 and D > 0.216, but p is 2.6e-5 and 4.9e-4 at 17 and 21 C (median over 1000 draws); with the permutation shuffle every p is below 1e-5 but D at 21 C is 0.199. The attempt applied the explicit reproduced clause (reproduced); if p < 1e-5 decides, no reading meets both bounds and the claim would be partially reproduced.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Coupling of the gastric mill and pyloric rhythms across temperature (Powell et al. 2021)

Tests the findings of Powell, Haddad, Gorur-Shandilya and Marder (2021) on Zenodo record 3924718, which holds the spike times, temperature and stimulation mask of the ten preparations in which gastric mill rhythms were evoked, and raw recordings. It tests the temperature dependence of the LG and PD burst periods, their Q10s, the slowing after stimulation, integer coupling of LG and DG with PD, and the phase of LG and DG in the PD cycle. The spontaneous recordings and those with the pyloric pacemaker hyperpolarized are not in the record. All files

Environment: Python 3.13, 28 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-25
    Agreed with 20 of 22 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The first executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper's full text (PMC7889077). The verifier checked the Zenodo record's file list and the preview of 941_006.zip, and tested the helpers on synthetic inputs (bursts, rayleigh, ks_2samp_asymp, measure_phase, integer_coupling, integerness, q10_methods, q10_code). It had no attempt record and took the claims from the claims file.
    • fig3-evoked-7-to-21-in-9-of-10: the verifier’s outcome was “Reproduced”. On the criterion's literal wording. Cell 16 reports 8 of 10, failing 901_062 and 901_086, but the code also requires bins 7 and 21 to be present, which the criterion does not ask. 901_062 never reaches 21 C (0 s, T_max 19.3) and has bursts in every bin it was held at, so the literal reading gives 9 of 10. If 21 C must be reached, it is 8 of 10, which would fail the tolerance of 0. The added requirement is not stated as an assumption, and both counts should be reported. The Methods' 'in some preparations, 19 C was the warmest' fits two preparations topping out at 19 C. It could not check whether 901_062's run stopped at 19 C because no rhythm could be evoked at 21 C, and asked for a printout of 901_062's stimulation blocks and temperatures at the end of the recording.
    • fig6b-lg-start-counts: the verifier’s outcome was “Partially reproduced”. Cell 43, Methods rule: LG 3908 (in tolerance) and fraction 0.339 (in tolerance), but DG 3573 exceeds 3228 + 322.8. With the code rule all three pass, and pooling temperatures with >= 100 gives exactly LG 3816. The fraction under reading (a) is taken over combinations with at least one start (0.339); over all 90 it would be 0.544, a choice not stated as an assumption, though both are shown.
  • Round 2
    2026-11-25
    Agreed with 22 of 22 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The full executed notebook after the round-1 revision, with its conclusions and summary, the helper module, the claims file, the attempt record and the paper's full text. No finding in the record was rated critical, so none was reviewed as one.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • The claims file leaves open which bins a preparation 'was held at'. A bin counts as held when the recording spends at least 120 s in it, the 2-minute minimum step of the Methods ('a given temperature step was held for at least 2 minutes') and the code's (BurstPeriodsVsTime.m, 'temperature held for less than 2 minutes'). Counting every bin with any time in it gives 3 of 10, so the outcome rests on this choice, which is an assumption (assumed: true); the question is put to the paper's authors as a methods_unavailable finding.fig3-evoked-7-to-21-in-9-of-10
  • A preparation whose warmest held bin is 19 C (901_062) passes when it has a rhythm at every bin it was held at, as the criterion is worded; the count requiring 21 C as well (8 of 10) is shown beside it.fig3-evoked-7-to-21-in-9-of-10
  • 941_006 has no spike times in the record, so three of the four preparations are tested; the outcome does not depend on it under the Methods burst rule, since one similar of three allows at most two of four.fig3s1-spontaneous-and-evoked-similar
  • The spike times of a raw file are those within its samples in evoked_data.mat (the filename categorical), the stacked form of the same crabsort annotations the script reads per file.fig3s1-spontaneous-and-evoked-similar
  • The claims file does not say which temperatures enter the Methods' Q10. Two readings were run, every bin with bursts and only the bins held at least 120 s (the temperature steps of the Methods, "Spontaneous and evoked gastric mill rhythm temperature ranges"); both give the same outcome. T is the bin centre, f_T the mean of 1/period over bursts starting in the bin.fig4c-q10-about-2
  • PD periods above 5 s and LG periods above 50 s are removed before the Q10, as fig_burst_period.m does (the outlier filter the claims file cites for fig4b-periods-decrease-all-preps).fig4c-q10-about-2
  • A stimulation block is taken as running to the end of the recording when no stimulation follows, as MATLAB's temperature(stim:[]) is empty in BurstPeriodsVsTime.m; the mask's meaning (stimulation where 0) is taken from the code (findStimulationTimes.m, BurstPeriodsVsTime.m), as the record does not describe it.fig4s1-slowdown-after-stimulation
  • The paper used one shuffle draw per temperature; here the median D and p over 1000 draws are reported, as the criterion sets. p is the asymptotic p of MATLAB's kstest2.fig5d-lg-pd-integer-coupled
  • Bins with a single preparation have no SEM; their interval is taken as the value itself (the code draws them without an error bar).fig5e-lg-area-exceeds-dg
  • The reported ranges match the sample of the later code (commit 7a82b1f, first 50 starts), not the Methods' first 40, as the claims file anticipated; the outcome follows the Methods, as the criterion sets.fig6b-lg-phase-locked
  • The claims file's reading (a) does not say over which combinations the fraction is taken; both those with any start and all 90 are shown. The outcome is decided by the DG total, whichever is used.fig6b-lg-start-counts

Provenance

Attempt record
powell-2021-01
Paper
10.7554/elife.60454
Date
2026-11-25
Made by
An agent, run by CatalystNeuro
Dataset
ZENODO:3924718 (on ZENODO)
Version
3924718 (doi:10.5281/zenodo.3924718)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-18

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 10 findings reproduced, Powell et al. 2021

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/powell-2021/"><img src="https://encorescience.org/badge/papers/powell-2021.svg" alt="Encore: 10 findings reproduced, Powell et al. 2021"></a>

Or as Markdown:

[![Encore: 10 findings reproduced, Powell et al. 2021](https://encorescience.org/badge/papers/powell-2021.svg)](https://encorescience.org/papers/powell-2021/)

The same numbers are in this page’s JSON, under badge (how it is counted).