Papers / Park et al. 2019

Park et al. 2019 · Neuron

How the Internally Organized Direction Sense Is Used to Navigate

Eunhye Park, Stephen Keeley, Cristina Savin, James B. Ranck, André Antonio Fenton

Outcomes of 22 claims

  • 9 reproduced
  • 5 partially reproduced
  • 3 not reproduced
  • 5 blocked

Summary: In this data the paper's core result holds: head-direction tuning in medial entorhinal cortex degrades during arena rotation, while firing rates and the sub-second coupling of cell pairs are preserved. The preservation of internally referenced tuning in cell pairs did not reproduce, nor did its short-lived registration to the arena frame; the Methods and the paper's code normalise this tuning differently, and the record asks which was used. The link between frame-specific directional information and proximity to the shock zones, and the structure of decoding errors, were weaker than reported. Learning, LFP and the analyses of all MEC cells could not be tested, as only the 115 head-direction cells are deposited.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Attempts 2

1 current, 1 replaced

Every attempt on the paper, each with the datasets it used and their versions. An attempt on a dataset replaces the one before it on that dataset; the paper’s page shows the current ones.

  1. Attempt 012026-11-12replaced
    CRCNS:hc-20 unversioned files (the archive keeps no versions)
    22 claims · 9 findings about the data · protocol pilot-14
  2. Attempt 02Viewing2026-11-13current
    CRCNS:hc-20 unversioned files (the archive keeps no versions)
    22 claims · 13 findings about the data · protocol pilot-14

Claims

Reproducing Park et al. (2019) from CRCNS hc-20 17 Open in Colab

Reproduced9

  • Reproduced

    The head-direction cells have long-duration spikes and a mean firing rate of 1.41 ± 0.20 AP/s.

    Mean stable1 rate 1.392 AP/s (reading a) and mean over three trials 1.433 AP/s (reading b), both within 1.41 ±…

    STAR Methods, Data Analysis, paragraph 2hd-cell-rate
    From the paper

    MEC head direction cells were classified as cells with long duration action potentials (avg. width at 30% of the peak voltage 169.79 ± 4.58 ms) and average firing rate below 10 AP/s (avg. 1.41 ± 0.20 AP/s)

    Result

    Mean stable1 rate 1.392 AP/s (reading a) and mean over three trials 1.433 AP/s (reading b), both within 1.41 ± 0.20. The median is 0.668 AP/s. Two units fire above 10 AP/s in stable1, the paper's stated upper limit. Spike width is not tested.

  • Reproduced

    Rotation did not change locomotor speed relative to stable1, measured in either frame, but speed was lower in stable2 than in the other conditions.

    Mean speed per session from the TSD positions (2.1333 pixels/cm).

    Figure 1C, top left, and its legendfig1c-speed
    From the paper

    Effect of rotation on (top left) speed

    Reported statistics
    • repeated-measures ANOVA, Greenhouse-Geisser corrected, Tukey-Kramer HSD, F(2.02, 74.68) = 46.61, p = 10⁻¹⁴
    Result

    Mean speed per session from the TSD positions (2.1333 pixels/cm). With the 40 sessions whose tracking is not duplicated, reading (a), successive samples, gives F(1.94, 75.59) = 64.80, p = 7.6e-17 (the paper F(2.02, 74.68) = 46.61); stable2 10.76 cm/s against 14.63 to 15.60 for the others, each adjusted p below 0.0001 by Tukey HSD on the repeated-measures error term, and stable1 and the two rotating frames do not differ (adjusted p 0.08 to 1.00); the between-groups Tukey-Kramer HSD gives the same (0.38 to 1.00). Reading (b), 1 s steps, F(1.87, 72.82) = 55.86, p = 6.9e-15, gives the pattern with the between-groups test (others adjusted p 0.07 to 0.84) but not with the repeated-measures error term, where the room and arena frames differ (adjusted p = 0.0045). Reading (a) gives the pattern under either error term. With all 44 sessions, reading (a) gives a room-arena difference at adjusted p = 0.048 on the repeated-measures error term.

    Deviations from the paper’s method
    • The four sessions whose tracking duplicates another session's (1015R029, 1025R029, 1211R039, 1212R039) are left out of the main test, as one trial of each pair carries another day's tracking; they are kept in a variant.
    • Tukey HSD uses the repeated-measures error term of the ANOVA (an assumption; STAR Methods, Statistics, name Tukey-Kramer HSD after repeated-measures ANOVAs run in JMP), with the between-groups Tukey-Kramer HSD and paired t-tests as variants. The outcome is the same under both error terms (reading a).
  • Reproduced

    Firing rates of the head-direction cells were maintained across stable1, rotating and stable2.

    Mean rates 1.392, 1.710 and 1.198 AP/s in stable1, rotating and stable2; repeated-measures ANOVA with…

    Figure 1C, bottom left, and its legendfig1c-firing-rate
    From the paper

    Despite excellent navigation (Figure 1A), maintained firing rates

    Reported statistics
    • repeated-measures ANOVA, Greenhouse-Geisser corrected, F(1.34, 153.21) = 1.89, p = 0.17 (n = 115 cells)
    Result

    Mean rates 1.392, 1.710 and 1.198 AP/s in stable1, rotating and stable2; repeated-measures ANOVA with Greenhouse-Geisser correction (Mauchly p = 9.4e-17) F(1.35, 154.10) = 1.76, p = 0.184 (the paper F(1.34, 153.21) = 1.89, p = 0.17). Mean change +0.318 AP/s in rotation and -0.194 in stable2. Without the unit with the highest rotating rate (1001R523-P9C1, 40.1 AP/s in rotation, 7.8 in stable1) p = 0.275, and without it and 1024R157-P9C1 p = 0.29. Variants find differences, a Wilcoxon test of rotating against stable1 (p = 0.02) and the ANOVA on log rates (p = 0.0015), so the absence rests on the paper's test on raw rates.

  • Reproduced

    Directional tuning of head-direction cells was strongly degraded during rotation in both frames, more in the arena frame than in the room frame, and returned in stable2 (stable1 = stable2 > rotating room frame > rotating arena frame).

    Directionality differs across conditions, F(2.77, 315.60) = 72.66, p = 8.9e-34 (the paper F(3, 342) = 70.36).

    Figure 1C, bottom right, and its legend; Results, Degraded Directional Tuning, paragraph 1rests on an assumptionfig1c-directionality
    From the paper

    stable1 = stable2 > rotating-room frame > rotating-arena frame (p < 0.01; post hoc using Tukey-Kramer honest significant difference [HSD])

    Reported statistics
    • repeated-measures ANOVA, Tukey-Kramer HSD, F(3, 342) = 70.36, p = 10⁻³⁵ (n = 115 cells)
    • post hoc pairs: Tukey-Kramer HSD, p < 0.01
    Result

    Directionality differs across conditions, F(2.77, 315.60) = 72.66, p = 8.9e-34 (the paper F(3, 342) = 70.36). Means 0.460 stable1, 0.421 stable2, 0.344 room, 0.170 arena. With Tukey HSD on the repeated-measures error term, stable1 and stable2 do not differ (p = 0.27), room is below stable1 (p below 0.0001) and stable2 (p = 0.0019), and arena is below room (p below 0.0001), every required pair at p < 0.01. With the between-groups Tukey-Kramer HSD (variant) room is not below stable2 at p < 0.01 (p = 0.055), which would make the outcome partial. Bonferroni-corrected paired t-tests agree with the main reading (stable2 against room p = 0.0048, stable1 against stable2 p = 0.14). The outcome was partially reproduced before the first verification round, with the between-groups test.

    Deviations from the paper’s method
    • Greenhouse-Geisser applied, as Mauchly's test is significant (p = 0.0042); the paper's degrees of freedom, F(3, 342), are uncorrected.
    • Tukey HSD uses the repeated-measures error term of the ANOVA, an assumption. The STAR Methods (Statistics) name Tukey-Kramer HSD after repeated-measures ANOVAs run in JMP 12 without saying which error term, and the paper's F(3, 342) on 115 cells implies a within-cell error term. A between-groups HSD ignores that the four conditions are measured on the same cells. The outcome rests on this choice.
  • Reproduced

    Head direction decoded from stable1 ensemble tuning is relatively accurate in stable2 and relatively inaccurate and abruptly changing in both frames during rotation, although for some ensembles room-frame decoding is similar to stable2; seven ensembles of at least five head-direction cells were analysed.

    Seven sessions hold at least five head-direction units (four of 6 and three of 5).

    Results, Degraded Directional Tuning, paragraph 2; Figure 2A and 2Brests on an assumptionfig2-decoding-stable-vs-rotating
    From the paper

    Seven ensembles of R5 cells were analyzed ... Relatively accurate decoding of the stable2 recordings (Figure 2A) contrast with relatively inaccurate and abruptly changing decoding in both the room and arena spatial frames during rotation, although for some ensembles, decoding in the room frame was similar to decoding in the stable2 condition

    Result

    Seven sessions hold at least five head-direction units (four of 6 and three of 5). With 20-sample windows the stable2 error is below the arena-frame error in 4 of 7 ensembles and below the room-frame error in 4 of 7, by the median and by the mean absolute error, and the same with 4-sample windows. Stable2 decoding is near or above chance (90 degrees) in 1026R157, 1117R157 and 1121R157 (medians 102 to 135), where decoding the second half of stable1 from its first half is also poor (65 to 116 degrees). Room is decoded better than arena in 6 of 7. The outcome rests on the claims file's majority rule (four of seven), which the paper does not give.

    Deviations from the paper’s method
    • Windows without any tracked direction are dropped from training; the code would place them in the first bin.
    • The stable2 decoding of 1121R157 uses the first 15 min, as one of its stable2 files lasts 15 min.
  • Reproduced

    During rotation, frame-specific directional discharge alternated between signaling room and arena direction; four of seven ensembles showed an overall room preference and two of seven an arena preference.

    Of the 16 readings the criterion names (bins 10 or 45 degrees, probabilities from the rotating trial or…

    Results, Degraded Directional Tuning, paragraph 3; Figure S2A and S2B; Figure 2C legendrests on an assumptionfigs2-frame-preference
    From the paper

    4/7 ensembles showed an overall preference to signal room directions over arena directions and 2/7 showed an overall preference to signal arena directions over room directions

    Result

    Of the 16 readings the criterion names (bins 10 or 45 degrees, probabilities from the rotating trial or stable1, SD of the ΔIdir series or of stable1 Idir, no-preference margin a factor of 2 or both below 0.05), one gives 4 room- and 2 arena-preferring ensembles (45 degree bins, rotating-trial probabilities, ΔIdir SD, both below 0.05). The other 15 give 0 to 5 room and 0 to 1 arena; 14 of 16 give more room- than arena-preferring ensembles. Under the matching reading the room-preferring ensembles are 0930R029, 1004R029, 1022R029 and 1117R157 (p above 2 SD 0.605, 0.291, 0.199 and 0.054 against below 0.000, 0.000, 0.000 and 0.030) and the arena-preferring 1023R029 (0.000 against 0.367) and 1121R157 (0.041 against 0.061); two labels rest on differences of 0.02 to 0.03. The criterion reproduces the claim under any reading; the outcome rests on that one reading.

    Deviations from the paper’s method
    • Idir is undefined where the observed count never occurs at that direction in the reference trial (only with stable1 probabilities); an interval where any cell's Idir is undefined is left out.
    • The direction of an interval is the circular mean of its tracked samples.
  • Reproduced

    The frame preference ΔIdir does not vary systematically with head direction; its polar distribution over head direction in either frame is not biased toward the shock zones and does not differ from uniform.

    With 10 degree Idir bins and rotating-trial probabilities the average Rayleigh r is 0.166 (expected 0.17 ±…

    Results, Degraded Directional Tuning, paragraph 4; Figure S3 legendverifier disagreed at firstrests on an assumptionquestion to the readerwas not reproduced in attempt 01figs3-no-head-direction-bias
    From the paper

    did not significantly differ from uniform (average r = 0.17 ± 0.02; p > 0.17; Figure S3)

    Reported statistics
    • Rayleigh test, average r = 0.17 ± 0.02, p > 0.17
    Result

    With 10 degree Idir bins and rotating-trial probabilities the average Rayleigh r is 0.166 (expected 0.17 ± 0.02). With n the sum of the weights no test of 14 is significant (smallest p = 0.35); with n the number of bins one is (1121R157 room frame, p = 0.014). The other Idir readings give average r 0.180 to 0.264 and 1 to 5 significant tests of 14. A question on the claims file asked whether every test should have p > 0.17, the bound the paper reports; the reader answered on 2026-11-13 that the criterion stands (non-significance at 0.05), so the answer changed nothing here and the claim was not re-run. With the assumed n the smallest p is 0.35, so the tests would also meet that bound. The 10 degree, rotating-trial Idir reading is not the only one under which figs2-frame-preference reproduces; that claim matches with 45 degree bins and rotating-trial probabilities, and under that Idir reading 1 of 14 tests here is significant even with n the sum of the weights (smallest p = 0.040), so the claim would not be reproduced under it.

    Attempt 01: not reproduced. A difference in method between the two notebooks, the n of the weighted Rayleigh test, which the criterion leaves open. Both find an average r of 0.166 and one test of 14 below 0.05 with n the number of bins (1121R157, room frame, p = 0.0134 and 0.014). The earlier attempt took n as the number of bins (reading a) and the blind one as the sum of the weights (reading b, as in CircStat), under which no test is significant.

    Deviations from the paper’s method
    • The n of the weighted Rayleigh test is taken as the sum of the weights, the convention of the weighted Rayleigh test in CircStat (circ_rtest), the field's standard MATLAB toolbox; the paper does not say. With n the number of bins the claim is not reproduced (1 of 14 tests at p < 0.05). The Idir reading is the first the figs2 criterion lists, not the one under which figs2 reproduces (45 degree bins), where 1 of 14 tests is significant under either n. Both are assumptions the outcome rests on.
  • Reproduced

    The sub-second temporal coupling of head-direction cell pairs (Kendall correlations of spike counts at 40, 250 and 1000 ms) was maintained across stable1, rotating and stable2.

    146 simultaneously recorded head-direction pairs; one-way ANOVA of the Fisher-transformed Kendall tau over the…

    Figure 3B and its legend; Results, Degraded Directional Tuning and Maintained Temporal Coupling, paragraph 1fig3-hd-pair-correlations-preserved
    From the paper

    The three conditions did not differ at any of the timescales

    Reported statistics
    • 40 ms: ANOVA, F(2, 420) = 0.097, p = 0.9
    • 250 ms: ANOVA, F(2, 420) = 0.305, p = 0.7
    • 1000 ms: ANOVA, F(2, 420) = 0.44, p = 0.7
    Result

    146 simultaneously recorded head-direction pairs; one-way ANOVA of the Fisher-transformed Kendall tau over the three trials F(2, 435) = 0.098, p = 0.907 at 40 ms, 0.329, p = 0.72 at 250 ms, 0.483, p = 0.617 at 1000 ms (the paper F(2, 420) = 0.097, 0.305, 0.44). Tau in stable1 correlates with tau in rotation at r = 0.85 to 0.97. A repeated-measures ANOVA, a variant, finds small differences at 250 and 1000 ms (p = 0.034 and 0.036), with stable2 lowest. The units of every session share their first timestamp in every trial (0 of 132 session trials differ), so each pair is binned on a common origin; session 1017R035, whose stable2 header states a first timestamp of 5, holds one unit and forms no pair.

    Deviations from the paper’s method
    • 146 pairs where the paper's degrees of freedom imply about 141.
    • Counts binned from the spike times over each trial, not from the tracker samples.
  • Reproduced

    The room-frame decoding error histogram has strong minima at 110 and 350 degrees in the room frame, the directions of the leading edges of prominent orienting cues given the clockwise rotation; the minima correspond to the cue edges in the room frame but not in the arena frame.

    With the seven ensembles pooled and 20-sample windows, the mean absolute room-frame error by room-frame head…

    Results, Transient Allocentric Registration, paragraph 4; Figure 5C and 5Drests on an assumptionfig5c-error-minima-at-cues
    From the paper

    Interestingly, the room frame direction decoding error distribution showed strong minima at 110 ... in the room frame, which, given the clockwise arena rotation, are the directions at which the leading edges of prominent orienting cues were located

    Result

    With the seven ensembles pooled and 20-sample windows, the mean absolute room-frame error by room-frame head direction (reading a) has its two deepest minima in the bins starting at 100 and 340 degrees (centres 105 and 345), within 10 degrees of 110 and 350 by their bin centres. This is 1 of 32 combinations of window, pooling and reading, against 0.20 expected by chance for two minima placed at random; 10 others find one of the two minima (6.6 expected by chance) and the pooled reading (a) with 133 ms windows finds neither. Were the 32 rows independent, at least one would match both minima by chance with probability 0.18 (they share data, so this is rough). The pooled curve is shallow (Rayleigh r 0.032 under fig5-error-inhomogeneous reading i; mean error 63.2 to 91.3 degrees by head direction, mean 76.8), and the two minima lie 13.6 and 13.4 degrees below the mean but only 0.1 and 1.6 degrees below their lower neighbouring bin, so the match is weak support. The outcome rests on the pooled reading. Whether the minima match the cue positions cannot be tested.

    Deviations from the paper’s method
    • The paper does not say which recordings are pooled or which measure Figure 5C plots; the match is found with all seven ensembles pooled and the mean error by head direction, an assumption the outcome rests on.
    • The decoded direction is the start of the winning bin, as in the code, which biases the signed error by about -5 degrees; minima are located by their bin centres.

Partially reproduced5

  • Partially reproduced

    The paper analyses 115 dorsal MEC head-direction cells from 13 rats, among 353 MEC cells forming 556 cell pairs (Table S1), out of 1594 MEC single units recorded.

    The data set holds 115 head-direction units from 13 rats, matching the paper's 115 from 13 rats; per rat they…

    Results, Degraded Directional Tuning, paragraph 1; STAR Methods, Electrophysiology; Table S1cell-counts
    From the paper

    We recorded 115 dorsal MEC head-direction cells (Figure S1; Table S1) from 13 rats

    Result

    The data set holds 115 head-direction units from 13 rats, matching the paper's 115 from 13 rats; per rat they match Table S1 except R029 (40 against 41) and R523 (2 against 1), and both R523 units are named R523 in all their files. Applying the paper's criteria at p < 0.05 (reading b), with the Rayleigh test of the tuning curve's vector and n the spikes behind it, 110 of 115 pass; two units fire above 10 AP/s in stable1 (13.8 and 11.9), two have Kuiper p of 0.051 and 0.054, and three a Rayleigh p of 0.28 to 0.43 (two of them among the Kuiper failures). With n = 36 bins 83 pass, and with the Rayleigh test of the raw spike directions 110. Reading (b) is circular, as the deposited units were already selected as head-direction cells. The data set holds no other MEC units, so the 353 MEC cells and 556 MEC cell pairs of Table S1 cannot be counted; the measured values for them are the 115 units and the 146 simultaneously recorded pairs the data set holds, all head-direction cells. The paper analyses 142 head-direction pairs in Figure 4; 142 of the 146 have a defined 5 s internally referenced curve in every condition (fig4-internal-tuning-preserved), which may be how the paper counted them.

    Deviations from the paper’s method
    • Spike width cannot be applied (no waveforms are deposited).
    • Units matched across trials by tetrode and cluster in the file names, as FileNameList.xlsx is shifted for five units of session 1121R157.
    • The n of the Rayleigh test of the tuning curve's vector is not stated (STAR Methods, Quantifying Head-direction Signals, Directionality, "converted to a z statistic"); it is taken as the number of spikes behind the curve, with n = 36 bins shown as a variant. The count under reading (a) does not depend on it.
  • Partially reproduced

    The change in preferred direction differs across trial pairs (stable1-stable2 = stable1-rotating room frame > stable1-rotating arena frame), and is greater for every trial pair than between the two halves of stable1.

    Trial pairs F(2, 228) = 17.80, p = 6.6e-08 (the paper F(2, 228) = 10.54); four groups F(3, 456) = 19.62, p =…

    Figure 1D, left, and its legend; Results, Degraded Directional Tuning, paragraph 1question to the readerfig1d-preference-change
    From the paper

    The rotation-induced change in (left) directional preference differs across trial pairs

    Reported statistics
    • across the three trial pairs: repeated-measures ANOVA, F(2, 228) = 10.54, p = 10⁻⁵ (n = 115 cells)
    • trial pairs against the two halves of stable1: ANOVA, Dunnett's test against the stable1 halves, F(3, 456) = 15.38, p = 10⁻⁹
    Result

    Trial pairs F(2, 228) = 17.80, p = 6.6e-08 (the paper F(2, 228) = 10.54); four groups F(3, 456) = 19.62, p = 5.6e-12 (the paper F(3, 456) = 15.38). Every trial pair exceeds the stable1 halves by Dunnett's test (p = 0.019, 0.0073, below 0.0001). Stable1-stable2 and stable1-room do not differ (58 and 60 degrees, Tukey p = 0.94 on the repeated-measures error term, 0.95 between groups), but stable1-arena is larger (91 degrees, p < 0.0001), where the legend orders it below the other two. The criterion makes this partial. Whether the legend's order is garbled, as the round 1 verifier suggested, is asked of a reader (questions/park-2019.yaml); the claim is tested as written.

    Deviations from the paper’s method
    • Halves of stable1 are its first and second 15 min, as the claims file reads them.
  • Partially reproduced

    Directional instability (the KLD between tuning curves) differs across trial pairs and is greater for every trial pair than between the two halves of stable1.

    KLD on spike counts (reading a) gives trial pairs F(1.60, 182.42) = 11.74, p = 7.2e-05 (the paper F(1.62…

    Figure 1D, right, and its legend; Results, Degraded Directional Tuning, paragraph 1verifier disagreed at firstrests on an assumptionfig1d-instability
    From the paper

    the change in preferred direction of directional tuning and the overall change in directional tuning (''instability'') was greater across the two stable conditions and between the stable and rotating conditions than it was between the two halves of the first stable session (Figure 1D)

    Reported statistics
    • across the three trial pairs: repeated-measures ANOVA, Greenhouse-Geisser corrected, F(1.62, 184.22) = 7.78, p = 0.001 (n = 115 cells)
    • trial pairs against the two halves of stable1: ANOVA, Dunnett's test against the stable1 halves, F(3, 456) = 5.15, p = 0.002
    Result

    KLD on spike counts (reading a) gives trial pairs F(1.60, 182.42) = 11.74, p = 7.2e-05 (the paper F(1.62, 184.22) = 7.78) and four groups F(3, 456) = 13.74, p = 1.4e-08; stable1-stable2 and stable1-arena exceed the halves by Dunnett's test (p = 0.0044 and below 0.0001), but stable1-room does not (p = 0.13). KLD on rates (reading b) gives F(1.60, 182.29) = 8.47, p = 0.00084, four groups p = 0.0026, and only stable1-arena exceeds the halves (p = 0.0008). With the rates rescaled to the spike count before the Krichevsky-Trofimov estimate (a variant, as adding 0.5 to rates far below 1 flattens the probabilities) only stable1-arena exceeds the halves (p below 0.0001; the others 0.15 and 0.26). The criterion has no partial form; the outcome is partial because two of the three comparisons with the halves hold under reading (a). Read strictly, the claim is not reproduced.

    Deviations from the paper’s method
    • The criterion gives only the reproduced form. Partially reproduced is a judgement outside it, made because both ANOVAs and two of the three comparisons with the halves hold under reading (a); this is an assumption, and under a strict reading of the criterion the outcome would be not reproduced.
  • Partially reproduced

    The rat's relative proximity to one shock zone versus the other is anti-correlated with frame-specific directional information, so that near the room shock zone directional discharge favours the arena frame and the reverse; this holds for Idir in each frame (mean r = -0.141 ± 0.029, all p < 0.0001) and for ΔIdir (r = -0.18, p < 0.05, in the exemplar).

    Under every reading (Idir bins and probabilities, proximity a or b, and distance to the zone's centre, to its…

    Results, Degraded Directional Tuning, paragraphs 3 and 4; Figure 2C and its legend; Figure S2Cfig2c-proximity-anticorrelation
    From the paper

    This anticorrelation was observed for Idir defined for each spatial frame ... 0.141 ± 0.029; all p < 0.0001), as well as for their combination DIdir

    Reported statistics
    • Idir per frame against relative proximity, each ensemble: Pearson correlation, mean r = -0.141 ± 0.029, p < 10⁻⁴
    • Idir against relative proximity, second report: Pearson correlation, mean r = -0.132 ± 0.024, p < 10⁻⁴
    • ΔIdir against relative proximity, ensemble b: Pearson correlation, r = -0.18, p < 0.05
    Result

    Under every reading (Idir bins and probabilities, proximity a or b, and distance to the zone's centre, to its nearest point, or by angle about the arena centre to the zone's centre direction) the mean of the 14 frame-specific correlations is negative, -0.043 to -0.087 (first reading -0.0698), and none of the 24 is within -0.141 ± 0.029 or -0.132 ± 0.024; 9 to 12 of 14 are negative and 7 to 11 negative with p < 0.0001, never all 14. ΔIdir correlates negatively with proximity at p < 0.05 in 4 to 6 of 7 ensembles (mean r -0.040 to -0.128). The criterion makes this partial under every reading, so the outcome does not rest on how the distance is measured.

    Deviations from the paper’s method
    • The paper does not define the distance to a shock zone. Three are run, to the zone's centre (centre angle and mid radius from the tracker headers, angle counted with y up as the tracker's zone flags show), to its nearest point (0 inside), and the angle about the arena centre between the rat and the zone's centre direction. They give the same outcome.
  • Partially reproduced

    The angular distribution of decoding error is inhomogeneous in the room frame (resultant r = 0.589) and the arena frame (r = 0.653) and differs from the distribution of sampled head directions, which is itself biased in both frames (r = 0.147 room, r = 0.378 arena).

    A reader amended the criterion on 2026-11-13 in answer to a question (questions/park-2019.yaml) so that it…

    Results, Transient Allocentric Registration, paragraph 4; Figure 5A and 5B and the legendquestion to the readerfig5-error-inhomogeneous
    From the paper

    The angular distribution of the decoded directional error was not homogeneous in the room frame (Figure 5A; resultant vector r = 0.589; Rayleigh’s test; z = 236.36; p = 0.000); nor was the error distribution similar to the head-direction distribution

    Reported statistics
    • room-frame error, uniformity: Rayleigh's test, r = 0.589, z = 236.36, p = 0
    • room-frame error against head directions: Kuiper's test, V = 4.17 × 10^7, p = 0.001
    • arena-frame error, uniformity: Rayleigh's test, r = 0.653, z = 289.63 (the legend prints 153.24 and 230.58), p = 10⁻⁴
    • arena-frame error against head directions: Kuiper's test, V = 5.38 × 10^7, p = 0.001
    • room-frame head directions, uniformity: Rayleigh's test, r = 0.147, z = 230.6, p < 10⁻⁴
    • arena-frame head directions, uniformity: Rayleigh's test, r = 0.378, z = 153.2, p = 0.001
    Result

    A reader amended the criterion on 2026-11-13 in answer to a question (questions/park-2019.yaml) so that it names three readings of what the error distribution is over, (i) mean absolute error per 10 degree head-direction bin, (ii) head directions of windows decoded within 15, 30 or 45 degrees, (iii) the signed error angles. Before the answer only (iii) was run. The claim was re-run under all three with the three pooling readings and both windows. Every test holds (all four distributions non-uniform, both Kuiper's tests at p < 0.05) in 75 of 80 combinations, but none has all four r within tolerance; the most is two. With the six-cell ensemble 0930R029 (reading b) and 20-sample windows, the room-frame r is 0.604 under reading (ii) at 15 degrees, 0.555 at 30 degrees and 0.560 under reading (iii), within tolerance of 0.589, and the arena-frame head-direction r is 0.360 (0.378); the arena-frame r is 0.484, 0.543 and 0.144 (0.653) and the room-frame head-direction r 0.072 (0.147). The measured values are those of reading (ii) at 15 degrees, the first listed reading with two r within tolerance. Reading (i) gives error r of 0.031 to 0.426 at 20 samples. Pooled (reading a) no r is within tolerance under any reading, and the medians over ensembles (reading c) reach at most 0.348 (room, reading ii at 666 ms) and 0.548 (arena, reading ii at 133 ms). The answer brings the arena-frame error r closer to 0.653 but not within tolerance, and leaves the outcome as it was under reading (iii) (partially reproduced, with measured values 0.560, 0.144, 0.0718 and 0.360). Four ensembles tie at six cells; the other three match at most one value under any reading. The paper's z values imply about 681 and 679 windows for the error distributions and 10,671 and 1,072 samples for the head-direction distributions; no row has both error counts within 10% of 681 and 679, and no ensemble or sum of ensembles matches the head-direction counts of both frames, so the paper's pooling cannot be recovered from the counts.

    Deviations from the paper’s method
    • For reading (i) the paper does not give the n of the Rayleigh test; it is taken as the number of decoded windows, as the paper's z = 236.36 at r = 0.589 implies about 680, and n = 36 bins is shown as a variant (which leaves the arena-frame error uniform for every ensemble). Neither choice changes the outcome, which readings (ii) and (iii) also give.
    • For reading (i) Kuiper's test compares the error weights with the head-direction occupancy over the same 10 degree bins, with n the number of windows on each side; the paper does not say how the test was applied to this reading.

Not reproduced3

  • Not reproduced

    The MEC head-direction cells showed no systematic tuning of firing rate to angular head velocity.

    In stable1, 12 of 115 units correlate with signed angular velocity at p < 0.05 (binomial p = 0.013 against 5%)…

    Results, Transient Allocentric Registration, paragraph 1rests on an assumptionno-angular-velocity-tuning
    From the paper

    There was no systematic tuning of firing rate to angular velocity in these MEC head-direction cells (data not shown).

    Result

    In stable1, 12 of 115 units correlate with signed angular velocity at p < 0.05 (binomial p = 0.013 against 5%) and 49 of 115 with unsigned angular velocity (p = 5.7e-33); rotating and stable2 give the same. The correlations are small (|r| at most 0.028 signed, 0.068 unsigned), and the sample-to-sample angular velocity reaches about 5400 degrees/s, which points to tracking noise. Tested against circular shifts of at least 30 s, which keep the serial dependence of the samples, 11 of 115 (binomial p = 0.029) and 41 of 115 (p = 3e-24) are significant, and after removing the head-direction bin means from both series 14 (p = 0.0019) and 34 (p = 1.8e-17), so the excess does not come from treating the samples as independent. The correlations are of both signs (49 to 53 of 115 positive for unsigned velocity) and at most 0.068 in size. The paper shows no data and names no test; the test is the claims file's assumption, and the outcome rests on it.

    Deviations from the paper’s method
    • The test (per-unit Pearson correlation with angular velocity from successive samples, and a binomial test of the fraction significant) is the claims file's assumption; the paper names none. Stable1 is the main trial, as the classification trial; the others are variants.
  • Not reproduced

    Internally referenced directional tuning of head-direction cell pairs (tuning of one cell to head-direction displacement since the other's spikes) was preserved across stable1, rotating and stable2; neither its instability nor its change in preference differed between trials or from the two halves of stable1.

    Under the main readings (5 s, cell 2 spikes before the cell 1 spike, the Methods' normalisation; 142 pairs…

    Results, Transient Allocentric Registration, paragraph 2; Figure 4B and 4D and the legendfig4-internal-tuning-preserved
    From the paper

    Internally referenced tuning to head-direction displacement was preserved across the stable and rotating conditions

    Reported statistics
    • instability across trial pairs: repeated-measures ANOVA, Greenhouse-Geisser corrected, F(1.70, 219.83) = 2.81, p = 0.07
    • preference change across trial pairs: repeated-measures ANOVA, Greenhouse-Geisser corrected, F(1.83, 248.26) = 0.42, p = 0.6
    • instability, trial pairs against stable1 halves: ANOVA, F(3, 522) = 1.39, p = 0.2
    • preference change, trial pairs against stable1 halves: ANOVA, F(3, 536) = 0.34, p = 0.8
    Result

    Under the main readings (5 s, cell 2 spikes before the cell 1 spike, the Methods' normalisation; 142 pairs with a defined curve in every condition) instability differs across trial pairs, F(2.00, 282.00) = 10.20, p = 5.3e-05, and in the four-group ANOVA, F(3, 564) = 3.76, p = 0.011, and the preference change across trial pairs, F = 6.39, p = 0.0019; only the four-group preference test has p ≥ 0.05 (0.125). The differences are small (mean KLD 0.148 to 0.207 against 0.166 for the halves; stable1-room the largest). Of the eight readings, only 5 s, before, with the code's occupancy normalisation has all four at p ≥ 0.05. Its KLD is near 0 (means about 0.001), as the Krichevsky-Trofimov 0.5 swamps the normalised values; with the curve rescaled to its spike count (variant) that reading still has all four at p ≥ 0.05, the instability test at p = 0.052.

    Deviations from the paper’s method
    • Cell 1 is the first-listed unit of each pair, as the code labels pairs i < j.
    • With the Methods' normalisation (a single number per curve) the curve is the spike-difference histogram; KLD uses its counts.
  • Not reproduced

    The strength of internally referenced directional tuning is similar in all conditions and frames for intervals up to 10 s, but beyond 10 s it falls in the rotating arena frame (20 to 60 s; stable1 = stable2 = rotating room > rotating arena) and at 300 to 600 s also in the rotating room frame (stable1 = stable2 > rotating room > rotating arena).

    Run under the four readings of window side and normalisation.

    Figure 4C and its legend; Results, Transient Allocentric Registration, paragraph 3verifier disagreed at firstrests on an assumptionfig4c-arena-registration-short-lived
    From the paper

    during short intervals in the rotating condition, the strength of internally referenced directional tuning was similar in the two spatial frames but less so across longer intervals (Figure 4C). Specifically, internally referenced arena-frame tuning abruptly decreased after 10 s.

    Reported statistics
    • condition by interval interaction: repeated-measures two-way ANOVA, Greenhouse-Geisser corrected, F(6.91, 1287.7) = 15.16, p = 10⁻¹⁷
    • conditions at each interval up to 10 s: one-way ANOVA, F(3, 564) ≤ 1.59 (printed with the glyph for ≥, read as ≤ since p > 0.19 at each interval), p > 0.19
    • conditions at each interval beyond 10 s: one-way ANOVA, Tukey-Kramer HSD, F(3, 564) ≥ 23.73 (printed with the glyph for ≤, read as ≥ since p < 10^-14 at each interval), p < 10⁻¹⁴
    Result

    Run under the four readings of window side and normalisation. With the Methods' normalisation and cell 2 spikes before, the conditions do not differ at 3, 4 and 5 s (p = 0.13, 0.17, 0.11) but do at 10 s (p = 0.0086); with cell 2 spikes after they differ at 5 s (p = 0.020) and 10 s (p = 0.0024); with the code's normalisation they do not differ up to 10 s with cell 2 before (p = 0.096 to 0.50) and differ at 10 s with cell 2 after (p = 0.0094). Every reading differs at every interval beyond 10 s (p below 0.002). The arena frame is below all three other conditions at none of 20 to 60 s with the Methods' normalisation, and only at 60 s (before) or 50 and 60 s (after) with the code's. With the Methods' normalisation the room frame falls as far as or further than the arena frame at 20 to 50 s (before, 40 s, 0.267 and 0.281 against 0.410 and 0.452). With the code's normalisation the room frame falls first (cell 2 before, below both stable trials at 20 s, where the arena frame is not), and the arena frame is lower from 40 s (0.180 against 0.204 before, 0.181 against 0.208 after) and below the room frame by Tukey's test from 50 s (after) or 60 s (before). At 300 and 600 s the arena frame is below the others in every reading, and the room frame below both stable trials with the Methods' normalisation, as reported, but not at 600 s with the code's. The code's normalisation with cell 2 before meets the words of the partial form (no difference up to 10 s, differences at every later interval, the arena frame below the other three at 60, 300 and 600 s, the room frame not below stable2 at 600 s). The outcome takes "beyond 10 s" in the partial form as from 20 s, the arena-frame part of the full criterion, and under that reading no reading of window side and normalisation meets it; read as any interval beyond 10 s, the outcome would be partially reproduced. The outcome was partially reproduced before the first verification round, when only cell 2 spikes before were run; the verifier gave not reproduced.

    Deviations from the paper’s method
    • Strength is the Rayleigh vector length of the internally referenced curve, the reading the claims file gives.
    • One-way ANOVA on 141 to 146 pairs per interval (pairs with a defined curve in all four conditions at that interval), with between-groups Tukey-Kramer HSD, as the criterion's one-way ANOVA implies.
    • The partial form ("the arena frame falls below the others beyond 10 s and not before, but the room-frame order at long intervals is not found") is read as requiring the arena-frame order of the full criterion, below the three others from 20 s, since it names only the room-frame order as missing, and the paper writes that arena-frame tuning "abruptly decreased after 10 s" while the ensemble registered to the room frame within about 10 s (Results, Transient Allocentric Registration, paragraph 3). This is an assumption the outcome rests on.

Not tested in a notebook 5

5 data missing from the dataset

Blocked5

  • Blocked

    The 13 recorded rats learned the place avoidance task, with performance improving over trials in the stable (baseline) and the rotating (challenge) conditions and no trial by frame interaction in the rotating condition.

    The learning curves are over the pretraining and training sessions.

    Data missing from the datasetFigure 1A legend; Results, Degraded Directional Tuning, paragraph 1fig1a-avoidance-learning
    From the paper

    right: learning curves from the 13 recorded rats in the stable [baseline]

    Reported statistics
    • stable condition, trial effect: repeated-measures ANOVA, Greenhouse-Geisser corrected, F(3.78, 46.01) = 3.79, p = 0.01 (n = 13 rats)
    • rotating condition, trial effect: repeated-measures ANOVA, Greenhouse-Geisser corrected, F(3.76, 90.29) = 23.57, p < 0.001
    • rotating condition, trial by frame interaction: repeated-measures ANOVA, Greenhouse-Geisser corrected, F(3.76, 90.29) = 0.31, p = 0.86
    Result

    The learning curves are over the pretraining and training sessions. The data set's 176 tracker files hold only the 44 recording sessions (stable1, rotating in room and arena coordinates, stable2), 1 to 12 per rat; the training sessions are not deposited, and the data descriptor does not mention them.

  • Blocked

    Power in the MEC local field potential did not differ across conditions.

    The data set holds no LFP; the zip holds only TSD spike and tracking files and tracker .dat files, and the…

    Data missing from the datasetFigure 1C, top right, and its legend; Results, Degraded Directional Tuning, paragraph 1fig1c-lfp-power
    From the paper

    Despite excellent navigation (Figure 1A), maintained firing rates, and power in the local field potential (LFP)

    Reported statistics
    • ANOVA, F(2, 183) = 1.27, p = 0.28
    Result

    The data set holds no LFP; the zip holds only TSD spike and tracking files and tracker .dat files, and the data descriptor does not mention LFP.

  • Blocked

    Cell-pair discharge correlations among all 556 MEC cell pairs were preserved across trials (r² > 0.55 between the two stable trials and r² ≥ 0.52 between stable1 and rotating).

    The claim uses all 556 MEC cell pairs. The data set holds only the 115 head-direction units (115 files in each…

    Data missing from the datasetResults, Degraded Directional Tuning and Maintained Temporal Coupling, paragraph 1; Figure S4figs4-all-pair-correlations-preserved
    From the paper

    these correlations were also preserved among all the MEC cell pairs that were recorded (n = 556 pairs), regardless of the spatial functional class of the cells (r2 > 0.55 across the two stable conditions; r2 R 0.52 across the first stable and rotating session; Figure S4)

    Result

    The claim uses all 556 MEC cell pairs. The data set holds only the 115 head-direction units (115 files in each trial folder, all listed in FileNameList.xlsx); the other MEC units are not deposited.

  • Blocked

    The 115 conventionally identified head-direction cells also score high in head-direction information estimated by the Gaussian process tuning model among the 921 modelled MEC cells.

    The claim compares the head-direction cells with the 921 modelled MEC cells, which are not deposited; only the…

    Data missing from the datasetFigure S5 legendfigs5-hd-cells-high-model-information
    From the paper

    The conventionally-identified cells also scored high in head-direction information, which validates the model-based approach.

    Result

    The claim compares the head-direction cells with the 921 modelled MEC cells, which are not deposited; only the 115 head-direction units are.

  • Blocked

    Cell-pair discharge correlations within the grid-tuned, position-tuned and speed-tuned subclasses of MEC cells are maintained across stable and rotating trials.

    The grid, position and speed classes come from the 921 modelled MEC cells, which are not deposited.

    Data missing from the datasetFigure S6 legendfigs6-subclass-correlations-preserved
    From the paper

    Cell-pair specific discharge correlations within subclasses of spatially-tuned cells are maintained across the stable and rotating sessions.

    Result

    The grid, position and speed classes come from the 921 modelled MEC cells, which are not deposited.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Methods not availableStill presentFor Idir and ΔIdir (Figure 2C, S2, S3), the paper does not give the direction bins, the trial from which p(n|d) and p(n) are estimated, which SD the 2 SD rule uses, or the margin for no frame preference. The 4 room and 2 arena counts are found under 1 of 16 readings. Which were used?#
  • Methods not availableNewRelative proximity to the shock zones (Figure 2C) is not defined. Is it a normalised difference of distances to the zones, and measured to the zone centre, its nearest edge or by angle? Here none of 24 readings gives the reported mean r of -0.141.#
  • Methods not availableNewFor the Rayleigh test of the normalised ΔIdir over head direction (Figure S3), is n the number of bins or the sum of the weights? With n the number of bins one of 14 tests is significant here (p = 0.014); with the sum of weights none is.#
  • Methods not availableStill presentTukey-Kramer HSD followed repeated-measures ANOVAs (Figure 1C, 1D). Did the post hoc tests use the repeated-measures error term? For directionality the room frame against stable2 gives p = 0.0019 with it and p = 0.055 between groups, which decides the outcome here.#
  • Methods not availableNewFor internally referenced tuning (Figure 4), the Methods normalise the histogram by the sum of the time offsets and the code by the occupancy of each displacement; the strength measure of Figure 4C is not defined; and the Methods do not say on which side of the cell 1 spike the cell 2 spikes are taken. Which normalisation and strength measure were used? Under the Methods' normalisation the trial-pair differences of Figure 4D are significant here (p = 5.3e-05 for instability).#
  • Methods not availableNewWhich decoded windows are pooled in the Figure 5 error distributions (the Rayleigh z values imply about 680 windows), and which measure Figure 5C plots (error by head direction, or the signed error histogram)?#
  • Paper inconsistentStill presentfound on promptThe decoding window is 660 ms in the STAR Methods (20 samples of 33 ms, and num_samps = 20 in HD_Max_likelihood.py, 666 ms at the tracker's 30.02 samples/s) and 133 ms in the Figure 2 legend. The arena-frame error z is 289.63 in the Results and 153.24 and 230.58 in the Figure 5 legend, the z values the legend gives for the head-direction distributions.#

Questions about the claims 3

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • answered 2026-11-13asked 2026-11-12about fig5-error-inhomogeneous

    The criterion takes the resultant r of 0.589 and 0.653 as the Rayleigh resultant of the signed decoding error angles (decoded minus actual direction) of the rotating trial, tested against the sampled head directions by Kuiper's test. Does the paper instead mean a distribution over head direction, such as the head directions at which decoding is accurate, or the decoding error as a function of head direction, which is what it compares with the sampled head-direction distribution and what Figure 5C places at 110 and 350 degrees "in the room frame"?

    Passage. Results, paragraph on Figure 5, "The angular distribution of the decoded directional error was not homogeneous in the room frame (Figure 5A; resultant vector r = 0.589; Rayleigh's test; z = 236.36; p = 0.000); nor was the error distribution similar to the head-direction distribution (Kuiper's test; V = 4.17 x 10^7 ...)", and "the room frame direction decoding error distribution showed strong minima at 110 and 350 in the room frame". Figure 5 legend, "The polar distribution of room-frame directional error ... is inhomogeneous ... and different from the behavioral distribution".

    Why it matters. Kuiper's test against the head-direction distribution, and minima placed at room-frame directions, suggest that the polar distribution is over head direction. A distribution of signed error angles has no natural comparison with head directions. Under the claims file's reading the attempt finds error r of 0.014 to 0.211 against 0.589 and 0.653. Under a head-direction reading (head directions of windows decoded within 15, 30 or 45 degrees) it finds r of 0.10 to 0.55, the highest (0.53 to 0.55) in the arena frame at 133 ms, for the exemplar ensemble and the median over ensembles, still below 0.653. The reading decides which numbers are compared with the expected values, so it could change the outcome.

    The reader’s answer. Amended. The claims file fixed one reading where the paper allows more. The paragraph sets out to test whether, "when the rat faces the directions at which the internal representation registers, the associated ensemble discharge would tend to accurately decode to the current head direction", compares the error distribution with "the head-direction distribution" by Kuiper's test, and places its minima "at 110 and 350 in the room frame", all of which point to a distribution over head direction. The text also says "angular distribution of the decoded directional error", so the signed error angles remain a reading. The criterion of fig5-error-inhomogeneous now lists three readings, (i) mean absolute error per 10 degree head-direction bin as weights over the bin directions, (ii) head directions of accurately decoded windows (threshold not stated, 15, 30 and 45 degrees), (iii) the signed error angles, and the claim is reproduced under any distribution reading combined with any pooling reading. Expected values and tolerances are unchanged.
  • answered 2026-11-13asked 2026-11-12about figs3-no-head-direction-bias

    The criterion counts the claim reproduced when every weighted Rayleigh test has p ≥ 0.05. The paper reports p > 0.17. Should every test instead have p > 0.17, the threshold the paper states?

    Passage. Results, Degraded Directional Tuning, paragraph 4, "did not significantly differ from uniform (average r = 0.17 ± 0.02; p > 0.17; Figure S3)".

    Why it matters. Reported by the round 3 verifier. The criterion's threshold is looser than the paper's reported p. The attempt finds one of 14 tests at p = 0.0134 with n the number of bins, so the claim fails under either threshold and the outcome does not depend on this.

    The reader’s answer. Not changed. The finding is that the distribution "did not significantly differ from uniform"; p > 0.17 is the support the paper reports for it, and the claim records it under statistics. A claim of no effect is judged on non-significance at the usual 0.05 level, and the paper's average r = 0.17 ± 0.02 is the number the attempt must match, which stays in expected. Requiring p > 0.17 would turn a reported bound into a target the protocol does not ask for.
  • openasked 2026-11-13about fig1d-preference-change

    The statement and criterion take the order in the Figure 1D legend, "stable1-stable2 = stable1-rotating-room frame > stable1-rotating-arena frame", literally, so that the stable1-arena change in preferred direction must be the smallest of the three trial pairs. Could the legend be garbled, with the stable1-arena change meant to be the largest (stable1-stable2 = stable1-room < stable1-arena)? The arena frame is where directional tuning is most degraded (Figure 1C, stable1 = stable2 > room > arena), and a degraded curve would be expected to move its peak more. The Results text (page 4) states only that every pair exceeds the stable1 halves and gives no order.

    Passage. Figure 1 legend, (D), "The rotation-induced change in (left) directional preference differs across trial pairs (F2, 228 = 10.54; p = 10-5; stable1-stable2 = stable1-rotating-room frame > stable1-rotating-arena frame)." Results, page 4, "the change in preferred direction of directional tuning and the overall change in directional tuning ("instability") was greater across the two stable conditions and between the stable and rotating conditions than it was between the two halves of the first stable session (Figure 1D)."

    Why it matters. Reported by the round 1 verifier of park-2019-02. The order decides between reproduced and partially reproduced. The attempt finds both ANOVAs and all three Dunnett tests significant, stable1-stable2 and stable1-room equal (58 and 60 degrees, Tukey p = 0.94), and stable1-arena larger (91 degrees, p below 0.0001), the reverse of the legend's order.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction MEC head-direction cells on a rotating arena (Park, Keeley, Savin, Ranck and Fenton 2019)

Tests the findings of Park, Keeley, Savin, Ranck and Fenton (2019) on CRCNS data set hc-20, which holds the spike trains and 30 Hz tracking of 115 MEC head-direction cells from 13 rats in stable1, rotating (room and arena coordinates) and stable2 trials of the two-frame place avoidance task, with the tracker files of each trial. It ports the paper's maximum likelihood decoder and internally referenced tuning from its Python code, and tests directional tuning, its stability, Idir frame preference, cell-pair correlations and the decoding error distributions. The other MEC cells, the LFP and the training sessions are not in the data set. All files

Environment: Python 3.13, 37 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-13
    Agreed with 21 of 22 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The first executed notebook with the conclusion cells and the summary removed (one fig1d conclusion cell, whose heading did not begin "**Result:", was left in), the helper module and the claims file, with the paper's full text. The verifier checked the archive's file list for the blocked claims and tested rayleigh_p, kuiper_two_sample, kld, rm_anova, internal_tuning and the decoder on synthetic inputs. It had no attempt record.
    • fig4c-arena-registration-short-lived: the verifier’s outcome was “Not reproduced”. Under (a), p = 0.0086 at 10 s. At 20–60 s the room frame falls as much as or more than the arena frame; at 20 s arena > room. Under (b), the room frame falls first (20 s) and the arena frame is below the room frame only from 60 s. Neither normalisation shows the claimed room-preserved pattern. The "after" window side was computed only for 5 and 30 s, though the criterion asks for the window-side readings of fig4.
  • Round 2
    2026-11-13
    Agreed with 19 of 22 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The full executed notebook after the first revision, with its conclusion cells and summary, the helper module, the claims file, the README and this attempt record, with the paper's full text.
    • fig1d-instability: the verifier’s outcome was “Partially reproduced”. The criterion has no partial form, and the record says so. Partial is therefore a judgement outside the criterion (the verifier made the same one in round 1). Either mark it assumed with that reason, or give not reproduced.
    • figs3-no-head-direction-bias: the verifier’s outcome was “Reproduced”. The n = sum-of-weights assumption is stated and is reasonable (CircStat convention). Not stated is that the Idir reading used (10 degree bins) is not the only one under which figs2 reproduces (45 degree bins, rotating trial, ΔIdir SD, both below 0.05). Under the figs2 reading figs3 has 1 of 14 tests significant even with n = sum of weights (min p 0.039, cell 48), so it would not reproduce. The record should say so.
    • fig4c-arena-registration-short-lived: the verifier’s outcome was “Not reproduced”. The outcome depends on how "beyond 10 s" is read, and the record does not state that as an assumption. The before-side, code-normalisation reading meets the partial clause word for word (no differences up to 10 s, p < 0.05 at every later interval, arena below all three others at 60, 300 and 600 s, room not below stable2 at 600 s). Both 50 and 60 s are beyond 10 s, and "after the room frame" is not a condition in the criterion. Not reproduced is defensible if "beyond 10 s" is read as "from 20 s", which fits the paper's "abruptly decreased after 10 s" and its legend's 20 to 60 s order; the verifier's round-1 outcome made the same reading. Either mark it assumed and state that reading, or change it to partially reproduced. Separately, "at 20 to 50 s the room frame falls as far as or further than the arena frame" holds only with the Methods' normalisation; with the code's the arena frame is lower at 40 s (0.180 against 0.204 before, 0.181 against 0.208 after) and at 50 s.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • Spike width cannot be applied (no waveforms are deposited).cell-counts
  • Units matched across trials by tetrode and cluster in the file names, as FileNameList.xlsx is shifted for five units of session 1121R157.cell-counts
  • The n of the Rayleigh test of the tuning curve's vector is not stated (STAR Methods, Quantifying Head-direction Signals, Directionality, "converted to a z statistic"); it is taken as the number of spikes behind the curve, with n = 36 bins shown as a variant. The count under reading (a) does not depend on it.cell-counts
  • The four sessions whose tracking duplicates another session's (1015R029, 1025R029, 1211R039, 1212R039) are left out of the main test, as one trial of each pair carries another day's tracking; they are kept in a variant.fig1c-speed
  • Tukey HSD uses the repeated-measures error term of the ANOVA (an assumption; STAR Methods, Statistics, name Tukey-Kramer HSD after repeated-measures ANOVAs run in JMP), with the between-groups Tukey-Kramer HSD and paired t-tests as variants. The outcome is the same under both error terms (reading a).fig1c-speed
  • Greenhouse-Geisser applied, as Mauchly's test is significant (p = 0.0042); the paper's degrees of freedom, F(3, 342), are uncorrected.fig1c-directionality
  • Tukey HSD uses the repeated-measures error term of the ANOVA, an assumption. The STAR Methods (Statistics) name Tukey-Kramer HSD after repeated-measures ANOVAs run in JMP 12 without saying which error term, and the paper's F(3, 342) on 115 cells implies a within-cell error term. A between-groups HSD ignores that the four conditions are measured on the same cells. The outcome rests on this choice.fig1c-directionality
  • Halves of stable1 are its first and second 15 min, as the claims file reads them.fig1d-preference-change
  • The criterion gives only the reproduced form. Partially reproduced is a judgement outside it, made because both ANOVAs and two of the three comparisons with the halves hold under reading (a); this is an assumption, and under a strict reading of the criterion the outcome would be not reproduced.fig1d-instability
  • Windows without any tracked direction are dropped from training; the code would place them in the first bin.fig2-decoding-stable-vs-rotating
  • The stable2 decoding of 1121R157 uses the first 15 min, as one of its stable2 files lasts 15 min.fig2-decoding-stable-vs-rotating
  • Idir is undefined where the observed count never occurs at that direction in the reference trial (only with stable1 probabilities); an interval where any cell's Idir is undefined is left out.figs2-frame-preference
  • The direction of an interval is the circular mean of its tracked samples.figs2-frame-preference
  • The paper does not define the distance to a shock zone. Three are run, to the zone's centre (centre angle and mid radius from the tracker headers, angle counted with y up as the tracker's zone flags show), to its nearest point (0 inside), and the angle about the arena centre between the rat and the zone's centre direction. They give the same outcome.fig2c-proximity-anticorrelation
  • The n of the weighted Rayleigh test is taken as the sum of the weights, the convention of the weighted Rayleigh test in CircStat (circ_rtest), the field's standard MATLAB toolbox; the paper does not say. With n the number of bins the claim is not reproduced (1 of 14 tests at p < 0.05). The Idir reading is the first the figs2 criterion lists, not the one under which figs2 reproduces (45 degree bins), where 1 of 14 tests is significant under either n. Both are assumptions the outcome rests on.figs3-no-head-direction-bias
  • 146 pairs where the paper's degrees of freedom imply about 141.fig3-hd-pair-correlations-preserved
  • Counts binned from the spike times over each trial, not from the tracker samples.fig3-hd-pair-correlations-preserved
  • The test (per-unit Pearson correlation with angular velocity from successive samples, and a binomial test of the fraction significant) is the claims file's assumption; the paper names none. Stable1 is the main trial, as the classification trial; the others are variants.no-angular-velocity-tuning
  • Cell 1 is the first-listed unit of each pair, as the code labels pairs i < j.fig4-internal-tuning-preserved
  • With the Methods' normalisation (a single number per curve) the curve is the spike-difference histogram; KLD uses its counts.fig4-internal-tuning-preserved
  • Strength is the Rayleigh vector length of the internally referenced curve, the reading the claims file gives.fig4c-arena-registration-short-lived
  • One-way ANOVA on 141 to 146 pairs per interval (pairs with a defined curve in all four conditions at that interval), with between-groups Tukey-Kramer HSD, as the criterion's one-way ANOVA implies.fig4c-arena-registration-short-lived
  • The partial form ("the arena frame falls below the others beyond 10 s and not before, but the room-frame order at long intervals is not found") is read as requiring the arena-frame order of the full criterion, below the three others from 20 s, since it names only the room-frame order as missing, and the paper writes that arena-frame tuning "abruptly decreased after 10 s" while the ensemble registered to the room frame within about 10 s (Results, Transient Allocentric Registration, paragraph 3). This is an assumption the outcome rests on.fig4c-arena-registration-short-lived
  • For reading (i) the paper does not give the n of the Rayleigh test; it is taken as the number of decoded windows, as the paper's z = 236.36 at r = 0.589 implies about 680, and n = 36 bins is shown as a variant (which leaves the arena-frame error uniform for every ensemble). Neither choice changes the outcome, which readings (ii) and (iii) also give.fig5-error-inhomogeneous
  • For reading (i) Kuiper's test compares the error weights with the head-direction occupancy over the same 10 degree bins, with n the number of windows on each side; the paper does not say how the test was applied to this reading.fig5-error-inhomogeneous
  • The paper does not say which recordings are pooled or which measure Figure 5C plots; the match is found with all seven ensembles pooled and the mean error by head direction, an assumption the outcome rests on.fig5c-error-minima-at-cues
  • The decoded direction is the start of the winning bin, as in the code, which biases the signed error by about -5 degrees; minima are located by their bin centres.fig5c-error-minima-at-cues

Provenance

Attempt record
park-2019-02
Paper
10.1016/j.neuron.2018.11.019
Date
2026-11-13
Made by
An agent, run by CatalystNeuro
Dataset
CRCNS:hc-20 (on CRCNS)
Version
unversioned (doi:10.6080/K0SF2TDN)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-14

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 9 findings reproduced, Park et al. 2019

It counts the paper’s findings reproduced in full in a current attempt, verified or not. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/park-2019/"><img src="https://encorescience.org/badge/papers/park-2019-reproduced.svg" alt="Encore: 9 findings reproduced, Park et al. 2019"></a>

Or as Markdown:

[![Encore: 9 findings reproduced, Park et al. 2019](https://encorescience.org/badge/papers/park-2019-reproduced.svg)](https://encorescience.org/papers/park-2019/)

The same numbers are in this page’s JSON, under badge (how it is counted).