Papers / Mehrotra et al. 2024

Mehrotra et al. 2024 · Current Biology

Hyperpolarization-Activated Currents Drive Neuronal Activation Sequences in Sleep

Dhruv Mehrotra, Daniel Levenstein, Adrian J. Duszkiewicz, Sofía Skromne Carrasco, Sam A. Booker, Angelika Kwiatkowska, Adrien Peyrache

Outcomes of 22 claims

  • 9 reproduced
  • 5 not reproduced
  • 8 blocked

Summary: The paper's main spiking findings held up, in this retrosplenial data and in its postsubiculum and frontal cortex recordings deposited elsewhere. Postsubiculum units enter the UP state in a dorsal-to-ventral sequence, ventral DOWN states last longer, and earlier-activating units show a larger firing overshoot at UP onset in all three regions. The traveling wave of high gamma LFP power did not reproduce, under LFP methods the paper leaves open. The DOWN-state reset of decoded head direction failed by one histogram bin, and its slower drift at UP onset on a step the Methods leave open. The Ih model and the ex vivo sag gradient were not tested: MATLAB was unavailable and the slice recordings are not deposited.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Mehrotra, Levenstein et al. (2024) on dandiset 000987 (retrosplenial cortex) 3 Open in Colab

Reproduced2

  • Reproduced

    In retrosplenial cortex, as in PoSub, units with a larger firing-rate overshoot at UP state onset (peak-to-mean ratio, PMR) enter the UP state earlier; UP onset delay and PMR are negatively correlated (Kendall tau = -0.28, n = 570 units from 14 sessions in 3 mice, p = 6.76e-21).

    Reading (a), all sorted units with the stored UP states, gives 570 entering units and Kendall tau = -0.2748 (p…

    Figure 5F legend; Results, Post-DOWN rebound suggests a widespread role for Ih in neuronal activation at UP onset, paragraph 4rests on an assumptionfig5f-rsc-pmr-onset
    From the paper

    We found a similar relationship in the frontal cortex ... and RSC (data available at DANDI:000987) (Figure 5F).

    Reported statistics
    • Kendall tau rank correlation, UP onset delay against PMR, tau = -0.28, p = 6.8 × 10⁻²¹ (n = 570 units from 14 sessions (3 mice))
    Result

    Reading (a), all sorted units with the stored UP states, gives 570 entering units and Kendall tau = -0.2748 (p = 8.1e-21; paper -0.28, p = 6.76e-21), within the tolerance of 0.028. Re-detected UP states (detectDOWNs_RSC.py procedure, 95% to 99% of DOWN states matched within 10 ms) give -0.274 with 568 units; UP states starting inside the sleep epochs give -0.281 with 574 units. Tau is negative with p < 0.05 in each of the 14 sessions (-0.567 to -0.323) and in each mouse (-0.417, -0.369, -0.334). Onset thresholds of 0.3 to 0.7 give -0.259 to -0.238. Reading (b) cannot be run as written because the files hold no waveforms; its rate half (wake rate below 10 Hz, with or without the 0.5 Hz floor) gives -0.342 to -0.329 (p below 1e-18), negative and significant but outside the tolerance. The statement's link to PoSub ("as in PoSub") is tested by fig5c-posub-pmr-onset.

    Deviations from the paper’s method
    • Which units enter is open (criterion readings a and b). Reading (b), putative EX units by trough-to-peak above 0.35 ms and open field rate below 10 Hz, cannot be applied, as the units carry no waveform; only its rate half was run. The outcome rests on reading (a), all sorted units, as Figure5F.py does; the count of entering units (570) equals the n of the Figure 5F legend, which supports it.
    • pynapple 0.11.4 replaces the unpinned pynapple version of the paper's code (a standard choice the criterion allows); compute_eventcorrelogram takes the same arguments.
  • Reproduced

    In rat frontal cortex, UP onset delay and PMR are also negatively correlated (Kendall tau = -0.22, n = 950 EX units from 25 sessions in 11 rats, p = 5e-21).

    With the EX units of the data set (CellIDs EAll) and its UP states (UPDOWNINtervals UPInts), 986 of 995 EX…

    Figure 5E legend; Results, Post-DOWN rebound suggests a widespread role for Ih in neuronal activation at UP onset, paragraph 4verifier disagreed at firstrests on an assumptiondata in CRCNS fcx-1 (Watson et al. 2016)fig5e-fc-pmr-onset
    From the paper

    We found a similar relationship in the frontal cortex (FC; data from Watson et al.

    Reported statistics
    • Kendall tau rank correlation, tau = -0.22, p = 5 × 10⁻²¹ (n = 950 EX units from 25 sessions (11 rats))
    Result

    With the EX units of the data set (CellIDs EAll) and its UP states (UPDOWNINtervals UPInts), 986 of 995 EX units over 27 sessions in 11 rats enter, and Kendall tau between UP onset delay and PMR is -0.221 (p = 2.3e-20; paper -0.22, p = 5e-21, n = 950 from 25 sessions), within the tolerance of 0.022. Without the two sessions with the fewest UP states (25 sessions, 965 units) tau is -0.221. With the spike-based ON intervals tau is -0.162 (p = 5.0e-11), outside the tolerance; with all units and UPInts -0.236. Tau is negative in 8 of the 10 rats where it is defined (p < 0.05 in 5) and in 21 of 27 sessions (p < 0.05 in 10). The DOWN and OFF intervals hold 0 to 15.6 Hz of population rate, against 5.8 to 182.6 Hz when shifted by 0.5 s. The 27 archives (88.9 GB) were streamed eight at a time and read in 965 s in the final run; in 18 the wide-band .eeg came before the members needed.

    Deviations from the paper’s method
    • Figure5E.py reads buzcode files (SlowWaves events, CellClass, spikes cellinfo) that CRCNS fcx-1 does not hold. The data set's own files stand in for them: UPInts of UPDOWNINtervals.mat for the SlowWaves UP states and EAll of CellIDs.mat for the CellClass EX units. The outcome rests on UPInts; the spike-based ON intervals give a tau outside the tolerance.
    • All 27 sessions are used; the paper used 25 (its dataset_DM.list is not in the code repository). The three sessions named by date (20140526_277um, 20140527_421um, 20140528_565um) are taken as one rat, which gives the paper's 11 rats.
    • The PETH, PMR and onset delay are those of fig5f-rsc-pmr-onset (Figure5F.py and Figure5E.py are the same procedure), with pynapple 0.11.4.

Not reproduced1

  • Not reproduced

    The RSC dataset holds 570 units recorded in 14 sessions from 3 mice.

    The dandiset holds 14 sessions from 3 mice (A7801 4 sessions, A7802 2, A7803 8), as stated, and 638 sorted…

    STAR Methods, Behavioral procedures, paragraph 2; Experimental model and study participant details, paragraph 2; Figure 5F legendrsc-dataset
    From the paper

    A total of 570 units were recorded from 14 sessions.

    Result

    The dandiset holds 14 sessions from 3 mice (A7801 4 sessions, A7802 2, A7803 8), as stated, and 638 sorted units, 68 more than 570 (1.119 times), outside the 10% band of 513 to 627, so the criterion's partial outcome does not apply either. No unit selection of the Methods gives 570 (606 units with at least 0.5 Hz in wake, 412 below 10 Hz, 380 both). Exactly 570 units cross half their mean rate within 155 ms of DU and enter the Figure 5F test (fig5f-rsc-pmr-onset), so the paper's "570 units were recorded", repeated in the dandiset description, appears to count those units. The count per session ranges from 31 to 71, as the description says. No session is deposited twice.

    Deviations from the paper’s method
    • The wake epochs of the files are taken as the open field exploration for the rate selections, which are shown only to explain the count.

The postsubiculum spike claims, on dandiset 000939 9 Open in Colab

Reproduced7

  • Reproduced

    In PoSub, PMR is negatively correlated with UP onset delay; earlier-activating EX units show a larger overshoot, and virtually no late-activating unit has a large PMR (Kendall tau = -0.19, n = 1,096, p = 8.34e-20).

    On DANDI:000939, the 16 sessions hold 1,657 units and 1,097 EX units, the paper's counts, and 1,096 EX units…

    Figure 5C; Results, Post-DOWN rebound suggests a widespread role for Ih in neuronal activation at UP onset, paragraph 2rests on an assumptiondata in DANDI:000939 (PoSub dataset, Duszkiewicz et al. 2024)fig5c-posub-pmr-onset
    From the paper

    As predicted, PMR was negatively correlated with UP state onset timing, with earlierspiking cells showing a larger overshoot (Figure 5C). Critically, virtually no units with a late activation at UP onset had a large PMR.

    Reported statistics
    • Kendall tau rank correlation, tau = -0.19, p = 8.3 × 10⁻²⁰ (n = 1,096 EX units (1 of 1,097 excluded as it did not reach 50% of its mean rate within 150 ms))
    Result

    On DANDI:000939, the 16 sessions hold 1,657 units and 1,097 EX units, the paper's counts, and 1,096 EX units enter, as in the Figure 5C legend. With the paper's event files, and the states of A3708-200317b re-detected, tau = -0.177 (p = 3.7e-17), within 0.019 of -0.19. Without A3708-200317b tau is -0.195 (1,049 units). With the event file of A3708-200317b as it is, tau is -0.126 (p = 2.0e-9), outside the tolerance; with all states re-detected (an approximation of detectDOWNs_PoSub.py without its accelerometer step), -0.077. Tau is negative in all 16 sessions, with p < 0.05 in 7. No unit with an onset of 75 ms or more (46 units) has a PMR above 1.5 (largest 1.32), against 39% of the 198 units with an onset below 25 ms, as the statement says. The DOWN starts re-detected from the spikes and those of the 15 other event files cross-correlate with a sharp peak at -2.5 to -17.5 ms (25 to 67 times the flanks), so no event file is offset by tens of ms.

    Deviations from the paper’s method
    • The DOWN and UP states are the paper's event files (Analysis/OutputFiles, commit 4ee34f3), which the criterion names. The event file of A3708-200317b does not share the clock of that session's NWB spikes (population rate inside its DOWN states 454.7 Hz, the same as for intervals shifted by 0.5 s; no shift from -6,000 to +6,000 s brings it below 309 Hz), so its states were re-detected from the spikes with the procedure of detectDOWNs_RSC.py on the file's NREM within the home cage epochs, UP states restricted to NREM as detectDOWNs_PoSub.py does. The outcome rests on this replacement; with the event file as it is, tau is outside the tolerance.
    • EX units are the file's is_excitatory flag; the code also requires a gd flag the files do not hold. The counts (1,097 EX, 1,096 entering) match the paper's.
    • NREM is the file's sleep_states NREM within the home cage epochs, as detectDOWNs_PoSub.py intersects the sleep scoring with the sleep epochs; it is used only for the re-detection of A3708-200317b.
  • Reproduced

    An Isomap projection of the DU-aligned PETHs of all PoSub EX units shows a continuous gradation of profiles whose first dimension correlates strongly with PMR (Pearson R = 0.88, n = 1,096).

    On the PETHs of the 1,096 units of fig5c-posub-pmr-onset, sklearn Isomap (2 components, 50 neighbours) gives a…

    Figure 5D; Results, Post-DOWN rebound suggests a widespread role for Ih in neuronal activation at UP onset, paragraph 3data in DANDI:000939fig5d-isomap-pmr
    From the paper

    Isomap decomposition of the DU-PETHs of all PoSub units (Figure 5D) revealed a continuous gradation of temporal profiles at the UP state onset, which was largely attributable to a single dimension strongly correlated with PMR

    Reported statistics
    • Pearson correlation, first Isomap dimension against PMR, R = 0.88, p = 0 (n = 1,096 EX units from 16 sessions (16 mice))
    Result

    On the PETHs of the 1,096 units of fig5c-posub-pmr-onset, sklearn Isomap (2 components, 50 neighbours) gives a first dimension correlated with PMR with abs R = 0.865 (p printed as 0) over -250 to +250 ms, the Methods window, within 0.088 of 0.88; over the code's 0 to 155 ms window abs R = 0.875. The second dimension correlates with UP onset delay (R = -0.535 and -0.562).

    Deviations from the paper’s method
    • Uses the units and PETHs of fig5c-posub-pmr-onset, so it shares its replacement of the states of A3708-200317b.
  • Reproduced

    PoSub neurons activate with reliable delays after the DU transition, ranging from 5 to 100 ms (99th percentile range).

    Under reading (b), the 1st and 99th percentiles of the 1,096 pooled UP onset delays are 5 and 100 ms, the…

    Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 1; Figures 1D to 1Fdata in DANDI:000939fig1e-delay-range
    From the paper

    Unlike UD transitions, neurons activated with reliable delays with respect to the DU transition (Figures 1D-1F and S1I), ranging from 5 to 100 ms (99th percentile range)

    Result

    Under reading (b), the 1st and 99th percentiles of the 1,096 pooled UP onset delays are 5 and 100 ms, the paper's range. Under reading (a), the 0.5th and 99.5th percentiles are 0 and 110 ms, the lower bound outside 4.5 to 5.5 ms. The delays lie on the 5 ms grid of the PETH, and the percentile method (linear, lower, higher, nearest) changes neither reading. The measured values are reading (b), the one that matches.

    Deviations from the paper’s method
    • The paper does not define "99th percentile range"; the criterion names two readings, and only (b), 1st to 99th percentile, matches.
  • Reproduced

    At the DOWN-to-UP transition PoSub EX units activate in sequence, dorsal units entering the UP state before ventral ones; the per-session correlation of UP onset delay with depth is consistently non-zero for DU and not for UD transitions.

    Per session, the Kendall tau of UP onset delay against position is negative in 15 of 16 sessions (median…

    Figure 1E to 1G; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 1rests on an assumptiondata in DANDI:000939fig1g-dv-sequence-du
    From the paper

    This sequential activity followed an anatomical pattern... dorsally located units tended to enter the UP state before ventrally located units (Figure 1G; one-sample Wilcoxon test; DU, W = 1, n = 16

    Reported statistics
    • DU correlation coefficients against 0: one-sample Wilcoxon test, W = 1, p = 6.1 × 10⁻⁵ (n = 16 sessions)
    • UD correlation coefficients against 0: one-sample Wilcoxon test, W = 38, p = 0.13 (n = 16 sessions)
    • DU against UD correlation coefficients: Mann-Whitney U test, U = 52, p = 0.005 (n = 16 sessions)
    Result

    Per session, the Kendall tau of UP onset delay against position is negative in 15 of 16 sessions (median -0.309) and differs from 0 (one-sample Wilcoxon W = 1, p = 6.1e-5, the paper's values); the UD tau does not (W = 38, p = 0.13, the paper's values); DU and UD differ (Mann-Whitney U = 51, p = 0.0039; paper U = 52, p = 0.005). With the event file of A3708-200317b as it is (UD tau undefined there, 15 sessions) or without that session, the UD tau differs from 0 (W = 25, p = 0.048) and the claim would hold only in part; with all states re-detected it holds (UD p = 0.13, U p = 0.048). The result is fragile: the UD part rests on the re-detected states of the one session whose event file fails the clock check.

    Deviations from the paper’s method
    • The states of A3708-200317b are re-detected, as for fig5c-posub-pmr-onset; the UD part of the outcome rests on this.
    • Position is the rel_y of the unit's peak electrode (12.5 um steps), larger toward dorsal. The rel_y column is described only as "xy coordinate in electrode group"; the direction is from the probe description in the file ("Channels sorted top to bottom of shank"; electrode 0 has the largest rel_y in every session), and Figure1H.py also puts larger depth values dorsal.
    • The UD timing follows Figure1G.py (last bin above 0.5 between -150 and -5 ms of the PETH around DOWN starts, for units that also cross after +5 ms), with pynapple's correlogram in place of the code's crossCorr.
  • Reproduced

    DOWN states detected from ventral PoSub last longer than those detected from dorsal PoSub (Wilcoxon signed-rank test, W = 9, n = 16, p = 0.01).

    Ventral DOWN states are longer than dorsal ones with all units (median 107.5 against 97.5 ms, longer in 12 of…

    Figure 1H; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 1data in DANDI:000939fig1h-ventral-down-longer
    From the paper

    we found that the DOWN state durations were significantly longer in the ventral half when detected separately from the dorsal half of PoSub (Figure 1H; p = 0.01, Wilcoxon signed-rank test).

    Reported statistics
    • Wilcoxon signed-rank test, W = 9, p = 0.01 (n = 16 sessions)
    Result

    Ventral DOWN states are longer than dorsal ones with all units (median 107.5 against 97.5 ms, longer in 12 of 16 sessions, equal in 2; Wilcoxon W = 12, p = 0.011; paper W = 9, p = 0.01) and with EX units only (117.5 against 102.5 ms; W = 3, p = 0.0019). Both readings agree.

    Deviations from the paper’s method
    • The code's reading uses all units with a gd flag; the files hold no gd flag, so all units are used.
    • DOWN and UP states as for fig5c-posub-pmr-onset (A3708-200317b re-detected).
  • Reproduced

    HD information, linear speed and angular head velocity tuning of PoSub EX cells do not vary with DV position; resultant vector length and peak rate show weak but significant correlations with it.

    Over 1,097 EX cells in the square arena, speed score (tau = 0.029, p = 0.15) and AHV score (tau = 0.035, p =…

    Figure 1B; Figure S1D to S1F; Results, opening paragraphverifier disagreed at firstrests on an assumptionquestion to the readerdata in DANDI:000939fig1b-no-dv-tuning-gradient
    From the paper

    Across all behavioral correlates tested, we saw either no significant correlations (Figures 1B and S1D) or, at most, weak but significant correlations with DV location (Figures S1E and S1F)

    Reported statistics
    • HD information against depth: Kendall tau, tau = -0.03, p = 0.13 (n = 1,097 EX cells)
    • linear speed score against depth: Kendall tau, tau = -0.03, p = 0.18 (n = 1,097 EX cells)
    • AHV score against depth: Kendall tau, tau = -0.02, p = 0.23 (n = 1,097 EX cells)
    • resultant vector length against depth: Kendall tau, tau = 0.063, p = 0.002 (n = 1,097 EX cells)
    • peak firing rate against depth: Kendall tau, tau = 0.075, p = 2 × 10⁻⁴ (n = 1,097 EX cells)
    Result

    Over 1,097 EX cells in the square arena, speed score (tau = 0.029, p = 0.15) and AHV score (tau = 0.035, p = 0.081) do not vary with position; resultant vector length (tau = 0.061, p = 0.0026) and peak rate (tau = 0.077, p = 0.00014) increase toward larger rel_y, close to the paper's (0.063, p = 0.002; 0.075, p = 0.0002). HD information in bits per spike does not vary with position (tau = 0.034, p = 0.099); in bits per second, the formula as printed, it does (tau = 0.082, p = 5.1e-5), which would make the claim not reproduced. Figure 1B supports bits per spike: in the paper's PDF its axis of log10(HD info) runs from -2 to 1 with most cells between -0.5 and 0.5 and none beyond about 0.5; in bits per spike the median of log10 is 0.12 and the 99th percentile 0.46 (5 of 1,097 cells off the axis), in bits per second the median is 0.54, the 99th percentile 1.08, and 31 cells lie beyond 1. Figures 1B and S1D to S1F plot position from 0 (dorsal) to -0.8 mm (ventral), the direction of rel_y here, so resultant vector length and peak rate have the paper's positive sign; the three measures that do not vary have the opposite sign to the paper's (0.034, 0.029, 0.035 against -0.03, -0.03, -0.02), not significant here or in the paper, and no direction of the axis matches all five signs. Whether the criterion's "measures as the Methods define them" fixes the printed formula, in bits per second, is asked of a reader in questions/mehrotra-2024.yaml; the outcome is tested on the claims file as it is.

    Deviations from the paper’s method
    • HD information is taken in bits per spike. The Methods print the formula without division by the mean rate (bits per second) but use HD information in bits per spike to select cells for Isomap ("exceeding 0.2 bins/spike", Methods, Isomap Projection and Decoding, citing Duszkiewicz et al.; "bins" is read as a misprint for bits), and the range of Figure 1B (log10 HD info from -2 to 1, no cell beyond about 0.5) fits bits per spike and not bits per second; the outcome rests on this reading.
    • Resultant vector length and peak rate are not defined in the Methods; the standard definitions from the 1 degree tuning curve are used. Spikes are counted in the 100 Hz tracking frames.
    • Larger rel_y is dorsal: the probe description in the file says "Channels sorted top to bottom of shank", and electrode 0 has the largest rel_y in all 16 sessions.
    • The paper's tau is read with dorsal positive, as rel_y here: Figures 1B and S1D to S1F (read from the paper's PDF) plot "D-V pos. (mm)" from 0 at the top to -0.8 at the bottom. "Positively correlated" in the criterion is read in that direction; with ventral positive every tau changes sign (printed), and resultant vector length and peak rate would be negatively correlated.
  • Reproduced

    During NREM sleep, dorsal and ventral PoSub represent the same HD; the decoded angular difference is not different from that with shuffled cell depths.

    Under all four readings (halves by equal-width depth bins or by the median; mean or median absolute…

    Figure S1J; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 1data in DANDI:000939figs1j-dorsal-ventral-same-hd
    From the paper

    during NREM sleep, dorsal and ventral PoSub consistently represented the same HD

    Reported statistics
    • one-sample Wilcoxon test of z-scored difference from shuffle against 0, W = 38, p = 0.13 (n = 16 sessions)
    Result

    Under all four readings (halves by equal-width depth bins or by the median; mean or median absolute difference), the z-scored dorsal-ventral decoded angular difference does not differ from the depth shuffles (W = 40, p = 0.46; W = 31, p = 0.19 over 14 sessions; W = 59, p = 0.98; W = 56, p = 0.82 over 15 sessions). The paper reports W = 38, p = 0.13 over 16. Sessions with fewer than 10 bins with 5 HD cells spiking in each half are left out (A3709-200601 and A3713-200909a with equal-width halves).

    Deviations from the paper’s method
    • The Bayesian decoder is reimplemented in matrix form (Poisson likelihood, uniform prior, as pynapple's decode_1d), with tuning curves in 60 bins from the square arena; the paper gives the bin size of the decoding (50 ms) but not the tuning curve bins (a standard choice).
    • HD cells are the file's is_head_direction flag. A session needs 10 kept bins to enter (a standard choice to avoid empty sessions).

Blocked2

  • Blocked

    Across halves of a session, the delays of PoSub units at UP state onset are more stable than their timing at the UD transition (Wilcoxon signed-rank test, W = 4, n = 16, p = 0.0002).

    DU delays are more stable across halves than UD timings under three readings (first and second half with…

    Methods underspecifiedFigure S1I legend; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 1data in DANDI:000939figs1i-du-more-stable
    From the paper

    Half-session correlation for UP state onset and the UD transition suggests that the UP state onset is overall more stable than the UD transition

    Reported statistics
    • Wilcoxon signed-rank test, W = 4, p = 2 × 10⁻⁴ (n = 16 sessions)
    Result

    DU delays are more stable across halves than UD timings under three readings (first and second half with Kendall, 12 of 16 sessions, W = 16, p = 0.0052; odd and even DOWN states with Pearson, 13 of 16, W = 19, p = 0.0092, or Kendall, 16 of 16, W = 0, p = 3.1e-5) and not under the fourth (first and second half with Pearson, 8 of 16, W = 52, p = 0.43). The criterion blocks the claim when the readings disagree. The paper has no code or Methods text for Figure S1I; what is open is how the session is halved and which correlation is used, and the question is recorded for the paper's authors. For each half the spikes are counted in all UP states (so that with odd and even halves the UP state before each DOWN start is kept) and divided by the rate in the half's UP states.

  • Blocked

    UP onset delays of PoSub EX units are explained by DV position better than by NREM firing rate; per animal, the regression coefficients of delay on position exceed those on firing rate (Wilcoxon signed-rank, W = 19, n = 16, p = 0.009) and differ from 0 (one-sample Wilcoxon, W = 0, n = 16, p = 3.052e-5).

    With z-scored predictors and signed coefficients the claim holds (position larger in 15 of 16, W = 9, p =…

    Methods underspecifiedFigure S1K and S1L legends; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 1data in DANDI:000939figs1kl-not-firing-rate
    From the paper

    Finally, these neuronal activation sequences were not accounted for by differences in neuronal firing rates

    Reported statistics
    • position coefficients against firing-rate coefficients: Wilcoxon signed-rank test, W = 19, p = 0.009 (n = 16 animals)
    • position coefficients against 0: one-sample Wilcoxon test, W = 0, p = 3.1 × 10⁻⁵ (n = 16 animals)
    Result

    With z-scored predictors and signed coefficients the claim holds (position larger in 15 of 16, W = 9, p = 0.0010; position against 0 W = 0, p = 3.1e-5; paper W = 19, p = 0.009 and W = 0, p = 3.052e-5). With z-scored predictors and absolute coefficients the first test fails (12 of 16, W = 32, p = 0.065), and with raw predictors, whose coefficients per um and per Hz are on different scales, it fails too (0 of 16 and 9 of 16). The criterion blocks the claim when the readings disagree. The paper has no code or Methods text for Figure S1L; the question is recorded for the paper's authors.

The postsubiculum LFP claims, on dandiset 000939 3 Open in Colab

Not reproduced2

  • Not reproduced

    The rise in high gamma (70 to 150 Hz) power at UP onset travels along the DV axis, while its drop at the UD transition is synchronous.

    No reading gives both parts of the claim.

    Figure 2B to 2F; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 3verifier disagreed at firstdata in DANDI:000939fig2f-gamma-travels
    From the paper

    gh traveled in the DV direction during the UP state onset, mirroring the wave observed in single unit activity (Figures 2B- 2F; one-sample Wilcoxon test; DU, W = 21, n = 16, p = 0.013; UD, W = 68, n = 16, p = 1)

    Reported statistics
    • DU coefficients against 0: one-sample Wilcoxon test, W = 21, p = 0.013 (n = 16 sessions)
    • UD coefficients against 0: one-sample Wilcoxon test, W = 68, p = 1 (n = 16 sessions)
    • DU against UD: Mann-Whitney U test, U = 73, p = 0.04 (n = 16 sessions)
    Result

    No reading gives both parts of the claim. Main reading, the 13 sessions whose LFP is shown to share the clock of the spikes: aligned to DU (the Methods), the time of maximal slope of high gamma power depends on channel position (median tau -0.742 to -0.659; one-sample Wilcoxon W = 7 to 9, p = 0.0046 to 0.0081; paper W = 21, p = 0.013), but so does the time of maximal negative slope before the DOWN start (median tau -0.810 to -0.749, W = 0, p = 2.4e-4; paper p = 1), so the drop is not synchronous by this measure. Aligned to the delta peak (Figure 2D legend), the rise does not depend on position (p = 0.27 to 1.0). With the UD window written in the criterion (0 to 150 ms after the DOWN start) the delays are constant in 12 of 13 sessions and the UD test cannot be run. On all 16 sessions the picture is the same (DU p = 0.0017 to 0.0034; UD p = 3.1e-5 to 1.2e-4; delta peak DU p = 0.39 to 0.60). The delta-peak readings rest on 0.37 to 4.76 peaks per minute of NREM, so they are noisy. In A3708-200317b high gamma power rises neither after the re-detected DU (1.045 against 1.048 shifted) nor after the UP starts of its event file (0.997 against 0.998), so its LFP fits neither stream.

    Deviations from the paper’s method
    • The paper has no code for Figure 2. The readings of the criterion were all run (power as the absolute Hilbert transform or the square; DU or delta-peak alignment; two windows). For the UD measure the mirror window, -150 to 0 ms, was added, because the window as written lies after the drop.
    • The delta channel is the middle channel of the probe (a standard choice; the Methods name none) and faulty channels are left out. The LFP is downsampled by taking every second sample; filters run forward and backward within each NREM interval.
    • A3705-200306, A3708-200317b and A3711-200810b are left out of the main reading: their high gamma power rises after DU by no more than after the same times shifted by 0.5 s (rise over the shifted control 0.02 or less, against 0.053 to 0.357 in the other sessions), so their LFP is not shown to share the clock of the spikes. All 16 sessions are run as a variant.
    • The criterion blocks the claim when readings disagree; here every reading fails it, on different parts, so the outcome is not reproduced.
  • Not reproduced

    For sessions with a significant delay-depth correlation, the speed of the traveling UP onset is similar from spikes and from LFP (6.72 +/- 4.08 against 9.89 +/- 5.51 mm/s, Mann-Whitney U = 58, n = 13 and 15, p = 0.072).

    13 sessions have a significant unit delay-depth correlation, as in the paper.

    Figure S2E; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 3rests on an assumptiondata in DANDI:000939figs2e-speed-similar
    From the paper

    the speed of the traveling activity for significant sessions was similar when computed using either the LFP or spiking activity

    Reported statistics
    • Mann-Whitney U test, U = 58, p = 0.072 (n = 13 sessions (spikes) and 15 sessions (LFP))
    Result

    13 sessions have a significant unit delay-depth correlation, as in the paper. With speed as the slope of depth on delay, units give 6.97 +/- 4.38 mm/s (paper 6.72 +/- 4.08). On the 13 sessions whose LFP clock is shown, the LFP gives 15.96 to 39.50 mm/s under the eight readings of fig2f-gamma-travels (paper 9.89 +/- 5.51, none within it), different from the units under 7 of 8 readings (Mann-Whitney p = 3.2e-5 to 0.017) and not under one (absolute Hilbert, delta peak, 0 to 150 ms, 7 sessions, p = 0.097). On all 16 sessions the LFP gives 17.87 to 40.96 mm/s, different under all 8 (p = 1.6e-5 to 0.028). With speed as the inverse slope of delay on depth, units give 37.3 +/- 18.0 mm/s, far from the paper's, and no difference under 6 of 8 readings. The measured LFP value is the first reading (absolute Hilbert, DU, 0 to 150 ms, 12 sessions). Depth is rel_y in mm.

    Deviations from the paper’s method
    • The outcome rests on the speed definition, the slope of depth on delay, which reproduces the paper's unit speeds; the inverse-slope reading does not.
    • The LFP side carries the open details of fig2f-gamma-travels, and fig2f-gamma-travels, on which this claim depends, is not reproduced.
    • The main reading leaves out the three sessions whose LFP is not shown to share the clock of the spikes, as for fig2f-gamma-travels.

Blocked1

  • Blocked

    Per session, the delay-depth correlation computed from units agrees with that computed from high gamma LFP power (Pearson R = 0.62, n = 16, p = 0.01).

    On the 13 sessions whose LFP clock is shown, the per-session unit and LFP coefficients correlate positively…

    Methods underspecifiedFigure S2D legend; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 3data in DANDI:000939figs2d-lfp-spike-agree
    From the paper

    The correlation coefficients between UP onset delay and depth for individual sessions were well correlated between LFP and spikes (Figure S2D)

    Reported statistics
    • Pearson correlation, R = 0.62, p = 0.01 (n = 16 sessions)
    Result

    On the 13 sessions whose LFP clock is shown, the per-session unit and LFP coefficients correlate positively with p < 0.05 under 7 of 8 LFP readings (R = 0.567 to 0.788), within 0.062 of 0.62 with p < 0.05 under three (R = 0.623, 0.567, 0.653, all delta-peak readings), and not under the eighth (square, delta peak, -250 to 250 ms, R = 0.553, p = 0.0502). On all 16 sessions 6 of 8 reach p < 0.05 (R = 0.506 to 0.761), one within the tolerance (R = 0.590, p = 0.016), and the two absolute-Hilbert delta-peak readings do not (R = 0.412, p = 0.13; R = 0.462, p = 0.071). The criterion blocks the claim when the readings disagree on significance. The open LFP details are those of fig2f-gamma-travels.

    Deviations from the paper’s method
    • The main reading leaves out the three sessions whose LFP is not shown to share the clock of the spikes, as for fig2f-gamma-travels; all 16 are run as a variant.

The postsubiculum Isomap ring claims, on dandiset 000939 2 Open in Colab

Not reproduced2

  • Not reproduced

    The DOWN state resets the virtual HD signal; the angle at the start of an UP state is unrelated to the angle at the end of the previous UP state.

    Over 6,510 UP states of 16 sessions (up to 600 long UP states projected per session), the first…

    Figure 1J; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 2verifier disagreed at firstdata in DANDI:000939fig1j-down-resets-hd
    From the paper

    We found that the DOWN state resets this virtual HD signal, as there was no relationship between the angle represented at the end of an UP state and the beginning of the subsequent UP state (Figure 1J).

    Result

    Over 6,510 UP states of 16 sessions (up to 600 long UP states projected per session), the first above-threshold angle after DU is nearly unrelated to the last above-threshold angle before UD: the mean resultant length of the differences is 0.020, against 0.078 for the 99th percentile of 1,000 shuffles of the angle at UD. Under the criterion's test one of 20 bins lies outside the shuffles' minimum to maximum, a deficit at -0.47 rad (294 UP states, shuffle range 300 to 422), while the bin at zero difference is inside (409, range 368 to 491); so the outcome is not reproduced. With 10 bins one bin lies outside, with 36 two; with the mean angle of the last 150 ms before UD (5,043 UP states) two bins with 20 bins, one with 10 and none with 36. With this procedure a shuffle lies outside the range of the others in at least one of 20 bins 3.3% of the time. On the 14 sessions whose wake ring follows head direction (R >= 0.5; A3706-200313 0.114, A3730-210323b 0.328) two bins lie outside (resultant length 0.032). The outcome is fragile: with the rings fitted on two other random draws, one bin lies outside with seeds 3000 + k and none with seeds 2000 + k (resultant length 0.020 to 0.030 over the three draws, against shuffle 99th percentiles of 0.070 to 0.078), so the test fails by one bin in two of three draws. A run repeats exactly (the ring of A3701-191119 fitted twice with the same generator is identical). The absence of a relation holds in size; the envelope test fails by one bin. The wake ring follows head direction with R = 0.627 to 0.936 in the other 14 sessions, and the first threshold crossing after DU comes at a median of 35 to 75 ms per session (the Methods give 35 ms as the mode).

    Deviations from the paper’s method
    • The ring follows makeRing.py (commit 4ee34f3): HD cells by the file's is_head_direction flag (the code also needs a gd flag the files lack; the Methods' filter of 0.2 "bins/spike" (read as bits per spike) is not in the code), wake bins of 0.2 s above 2 cm/s, NREM steps of 10 ms with a 50 ms window around UP states longer than 0.5 s, square-root rates, Isomap with 2 components and 200 neighbours, the centre at the projection of an empty bin, and a radius threshold of one third of the mean wake radius.
    • For run time, the random half of the wake bins is capped at 2,500 bins and at most 600 long UP states per session are projected, drawn with a fixed generator per session (a standard choice). Two other draws (seeds 2000 + k and 3000 + k) are run to show the dependence on it.
    • Isomap uses the dense eigen solver in place of the default ARPACK, which starts from an unseeded random vector, so that the ring can come out rotated or reflected differently in each run (a standard choice that makes a run repeat). Each ring is oriented so that its angle increases with head direction in wake (7 of 16 reflected), as the solver's reflection is arbitrary and a reflection negates the angle differences; with the rings as the solver returns them one bin lies outside too.
    • The angle at UD is taken before the start of the DOWN state that ends at the UP state's start; the first post-DU angle is searched 0 to 150 ms after DU. Angle differences are pooled over sessions and the angle at UD is shuffled within each session.
  • Not reproduced

    During the UP onset sequence the represented HD changes less rapidly than later in the UP state (diffusion coefficients, Mann-Whitney U test, U = 54, n = 16, p = 0.006).

    With the steps below the radius threshold left out, the diffusion coefficient during the traveling UP state is…

    Figure 1K; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 2verifier disagreed at firstrests on an assumptiondata in DANDI:000939fig1k-hd-stable-at-onset
    From the paper

    Following the DOWN state, the represented HD maintained a specific direction throughout the duration of the UP onset sequence (Figure 1I) and changed less rapidly than later in the UP state (Figure 1K).

    Reported statistics
    • Mann-Whitney U test, U = 54, p = 0.006 (n = 16 sessions)
    Result

    With the steps below the radius threshold left out, the diffusion coefficient during the traveling UP state is lower than in the control interval in 10 of 16 sessions (median 0.373 against 0.439 per s), and the two-sided Mann-Whitney test finds no difference (U = 98, p = 0.27; paper U = 54, p = 0.006). With the circular variance as 2 ln(1/R) it is lower in 12 of 16 (U = 87, p = 0.13); with per-UP-state slopes averaged, in 6 of 16 (p = 0.25); on the 14 sessions whose ring follows head direction, in 8 of 14 (U = 83, p = 0.51). With the rings of two other random draws it is not significant either (p = 0.10 and 0.21). Keeping the steps below the threshold gives 12 of 16, U = 76, p = 0.052 in the main draw and p = 0.025 and 0.044 in the other two, near the paper's result, so the outcome rests on leaving them out.

    Deviations from the paper’s method
    • The ring and UP states are those of fig1j-down-resets-hd.
    • Assumed: steps below the radius threshold are left out of the cumulative circular variance. The Methods use the threshold "for computing angular direction" and start the slope at 35 ms because the threshold crossing varies between UP states, which implies that angles below the threshold are not used. Keeping them gives p = 0.052, 0.025 and 0.044 over three draws of the ring. The variance is averaged over a session's UP states and the slope taken from 35 to 150 ms (185 to 300 ms for the control); averaging per-UP-state slopes is shown too.
    • The circular variance is 1 - R, scipy.stats.circvar since SciPy 1.8; the older 2 ln(1/R) is shown too, as the paper does not give its SciPy version.

Not tested in a notebook 5

1 metadata insufficient, 2 method cannot be run here, 2 data missing from the dataset

Blocked5

  • Blocked

    At UP state onset ADN cells activate more synchronously than PoSub cells (s.d. of delays 10.38 +/- 5.74 ms against 15.54 +/- 5.42 ms), suggesting the PoSub sequence is generated locally.

    The ADN recordings come from Peyrache et al. 2015, for which the paper names no archive.

    Metadata insufficientFigure S2F and S2G; Results, Neuronal activity at the DU transition travels along the PoSub DV axis and is locally generated, paragraph 4data in PoSub at DANDI:000939; ADN from Peyrache et al. 2015 (ref. 14), for which the paper names no archivefigs2g-adn-synchronous
    From the paper

    At UP state onset, ADN cells activated more synchronously than in the PoSub (Figures S2F and S2G; standard deviation of delays, 10.38 ± 5.74 ms in ADN versus 15.54 ± 5.42 ms in PoSub

    Reported statistics
    • as printed in the Results: Mann-Whitney U test, U = 29, p = 0.016 (n = 16 PoSub and 9 ADN sessions)
    • as printed in the Figure S2G legend: Mann-Whitney U test, U = 30, p = 0.019 (n = 16 PoSub and 9 ADN sessions)
    Result

    The ADN recordings come from Peyrache et al. 2015, for which the paper names no archive. The paper's code names 9 ADN sessions (event files Mouse12-120806 to Mouse32-140822). DANDI:000056 (Peyrache et al. 2015, version 0.250624.0430) holds 8 of them (not Mouse32-140822), but its units table has only spike times (no location, shank or electrode), and its electrode locations read "unknown", so the ADN units cannot be told from the PoSub units recorded with them. CRCNS th-1 was not examined within the run. The PoSub half is available (fig1g-dv-sequence-du).

  • Blocked

    In an adapting Wilson-Cowan array, gradients of excitability, recurrence or adaptation produce an inactivation sequence at the UD transition, not the observed activation sequence at DU only, over all parameter values tested.

    The model code (Model/Figure3.m, FigureS3b.m to FigureS3d.m, commit 4ee34f3) is MATLAB, which cannot be…

    Method cannot be run hereFigures 3B to 3D and S3B to S3D; Results, An Ih gradient can account for DV sequential activation at UP state onset, paragraph 2data in github.com/PeyracheLab/MehrotraLevenstein_2023 at commit 4ee34f3, Model/ (simulation code; no recorded data)fig3-other-gradients-fail
    From the paper

    we found that none of these parameter gradients were able to account for our primary observation... synchronous deactivation at the UD transition but sequential activation at UP state onset

    Result

    The model code (Model/Figure3.m, FigureS3b.m to FigureS3d.m, commit 4ee34f3) is MATLAB, which cannot be installed in the locked Python environment; neither MATLAB nor Octave is available on the runner. A port of the model to Python was not attempted.

  • Blocked

    A gradient of an h current (Ih) in the model produces synchronous UD transitions and a DV activation sequence at DU, robustly over a range of parameters.

    As fig3-other-gradients-fail; Model/Figure3.m and FigureS3f.m are MATLAB.

    Method cannot be run hereFigure 3E, 3F and S3F; Results, An Ih gradient can account for DV sequential activation at UP state onset, paragraph 3data in github.com/PeyracheLab/MehrotraLevenstein_2023 at commit 4ee34f3, Model/fig3f-ih-gradient
    From the paper

    As a result, an Ih gradient led to synchronous UD and sequential activation at UP state onset at the DU transition, as observed in our recordings (Figure 3F). Importantly, this property of the network was robust to a wide range of parameters (Figure S3F).

    Result

    As fig3-other-gradients-fail; Model/Figure3.m and FigureS3f.m are MATLAB.

  • Blocked

    Ex vivo, the Ih-mediated voltage sag of layer III PoSub EX cells decreases along the DV axis (Pearson R2 = 0.22, n = 59 cells from 11 mice, p = 0.0004), and the gradient is abolished by the HCN blocker ZD-7288 (R2 = 0.05, n = 19 cells from 8 mice, p = 0.36).

    The ex vivo whole-cell recordings are not in dandiset 000987, which holds only extracellular recordings, nor…

    Data missing from the datasetFigure 4D; Results, An Ih gradient can account for DV sequential activation at UP state onset, paragraph 4fig4d-sag-gradient
    From the paper

    We found a gradient of decreasing sag along the DV axis (Figure 4D) that was sensitive to an HCN-channel blocker

    Reported statistics
    • control: Pearson correlation, R2 = 0.22, p = 4 × 10⁻⁴ (n = 59 cells from 11 mice)
    • ZD-7288: Pearson correlation, R2 = 0.05, p = 0.36 (n = 19 cells from 8 mice)
    Result

    The ex vivo whole-cell recordings are not in dandiset 000987, which holds only extracellular recordings, nor in the paper's code repository; the paper's data availability statement names only the RSC dataset as deposited.

  • Blocked

    Resting potential, input resistance, membrane time constant, F-I slope and the fast time constant of sag do not vary with DV position in PoSub.

    As fig4d-sag-gradient; the ex vivo recordings are not deposited.

    Data missing from the datasetFigure S4A to S4G; Results, An Ih gradient can account for DV sequential activation at UP state onset, paragraph 4figs4-no-other-gradients
    From the paper

    Critically, no other DV gradients in passive properties or excitability were found in PoSub cells (Figure S4).

    Reported statistics
    • resting membrane potential, control: Pearson correlation, R2 = 0.02, p = 0.27 (n = 59 cells from 11 mice)
    • input resistance, control: Pearson correlation, R2 = 0.06, p = 0.06 (n = 59 cells from 11 mice)
    • membrane time constant, control: Pearson correlation, R2 = 0.06, p = 0.07 (n = 59 cells from 11 mice)
    • F-I slope: Pearson correlation, R2 = 0.009, p = 0.449 (n = 59 cells from 11 mice)
    • fast time constant of sag decay: Pearson correlation, R2 = 0.021, p = 0.302 (n = 59 cells from 11 mice)
    Result

    As fig4d-sag-gradient; the ex vivo recordings are not deposited.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Methods not availableQuestion for the paper's authors on Figure 5F. Which units enter the RSC test? All 638 sorted units give the legend's n of 570 entering units and tau = -0.275; the Methods say only EX units were analysed, which the deposited files cannot reproduce (no waveforms). This attempt assumed all units.#
  • Published code disagreesIn the paper's code (commit 4ee34f3), the DOWN and UP event file of PoSub session A3708-200317b does not fit the spikes of that session in DANDI:000939 (version 0.261016.2310); the population rate inside its DOWN states (454.7 Hz) equals that of shifted intervals (455.8 Hz), and no shift within 6,000 s fits. The other 15 event files fit (0.0 to 136.7 Hz inside DOWN states).#
  • Selection not documentedDANDI:000939 holds 31 mice; the paper used 16 sessions, and which ones is recorded only by the event files in the paper's code repository.#
  • Methods not availableQuestion for the paper's authors on Figure 1B. Is HD information in bits per spike or bits per second? The formula printed in the Methods gives bits per second, which correlates with depth here (tau = 0.082, p = 5.1e-5); bits per spike, the unit used for the Isomap cell selection, does not (p = 0.099). This attempt assumed bits per spike.#
  • Methods not availableQuestion for the paper's authors on Figure S1I. How is a session halved (first and second half, or alternating DOWN states), and which correlation is used? Three of four readings find DU more stable than UD; first and second half with Pearson's R does not (p = 0.40).#
  • Methods not availableQuestion for the paper's authors on Figure S1L. Were the predictors (DV position and NREM firing rate) standardized, and are the coefficients compared signed or in absolute value? Only standardized predictors with signed coefficients reproduce both tests.#
  • Methods not availableQuestion for the paper's authors on Figure 2 and S2D. How is high gamma power taken from the filtered LFP, is the UP onset delay measured from DU or from the delta peak, in which window is the maximal slope searched, and how is the UD timing measured on the LFP? Aligned to DU the rise travels but the drop before the DOWN start does too; aligned to the delta peak neither does.#
  • Methods not availableQuestion for the paper's authors on Figure S2E. Is the speed the slope of depth on delay or the inverse of the slope of delay on depth? The first gives the paper's unit speeds (6.97 against 6.72 mm/s) and was assumed.#
  • Selection not documentedThe paper's Figure 5E uses 25 sessions of CRCNS fcx-1, which holds 27; which 25 is recorded only in a list (dataset_DM.list) that the code repository does not hold.#
  • Published code disagreesFigure5E.py (commit 4ee34f3) reads buzcode files of the frontal cortex data (SlowWaves events, CellClass and spikes cellinfo) that CRCNS fcx-1 does not hold; the data set gives spike times, cell classes and UP and DOWN states in other files (SStable, CellIDs, UPDOWNINtervals).#
  • Methods not availableQuestion for the paper's authors on Figure 5E. Are the SlowWaves UP states of the code the UPInts of the data set's UPDOWNINtervals.mat, or the spike-based ON intervals, and which 25 sessions were used? UPInts give tau = -0.221 over 27 sessions, ON intervals -0.162. This attempt assumed UPInts.#
  • Methods not availableQuestion for the paper's authors on Figure 1K. Are the time steps whose ring radius is below the threshold left out of the cumulative circular variance, and is the variance averaged over UP states before the slope is taken? Leaving them out gives no difference between the traveling and control intervals (p = 0.27 over 16 sessions, and 0.10 and 0.21 with the rings of two other random draws); keeping them gives p = 0.052, 0.025 and 0.044, near the paper's result. This attempt assumed they are left out.#

Questions about the claims 1

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • openasked 2026-11-10about fig1b-no-dv-tuning-gradient

    The criterion takes HD information "as the Methods define them". The formula printed in the Methods (HD tuning curves and tuning metrics) has no division by the mean rate, so it gives bits per second, while the paper uses HD information in bits per spike elsewhere and the range of Figure 1B fits bits per spike. Should the criterion name the unit, bits per spike, or keep the formula as printed?

    Passage. "HD information contained in the tuning curves was calculated for N angular bins as: I = sum lambda(theta_i) log2(lambda(theta_i) / lambda) p(theta_i)" (STAR Methods, HD tuning curves and tuning metrics); "only cells with HD information exceeding 0.2 bins/spike (see Duszkiewicz et al. for details) were included" (STAR Methods, Isomap Projection and Decoding); Figure 1B, right, plots log10(HD info) on an axis from -2 to 1, most cells near 0.

    Why it matters. The outcome turns on the unit. In bits per spike HD information does not vary with depth (Kendall tau = 0.034, p = 0.099) and the claim is reproduced; in bits per second it does (tau = 0.082, p = 5.1e-5) and the claim is not reproduced. The verifier of round 1 read the criterion as the formula printed. In bits per spike the median of log10 HD information is 0.12 and the 99th percentile 0.46, as in Figure 1B; in bits per second the median is 0.54 and 31 of 1,097 cells lie beyond the axis.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction UP onset sequences in retrosplenial cortex and postsubiculum (Mehrotra, Levenstein et al. 2024)

Tests the findings of Mehrotra, Levenstein et al. (2024) on dandiset 000987, which holds the paper's retrosplenial cortex recordings (14 sessions, 3 mice), and, counted apart, on the paper's postsubiculum recordings in dandiset 000939. It measures the firing-rate overshoot and the delay with which units enter the UP state after a DOWN state, the dorsoventral sequence of these delays in postsubiculum, the longer ventral DOWN states, the head direction tuning along the probe, and the high gamma LFP at UP onset, the reset of the head direction signal by the DOWN state, and, on the rat frontal cortex data of CRCNS fcx-1, the same delay and overshoot relation. The model and the slice recordings are not tested. Also uses DANDI:000939. All files

Environment: Python 3.13, 54 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

  • Mehrotra, Levenstein et al. (2024) on dandiset 000987 (retrosplenial cortex)
    reproduce_mehrotra_2024.ipynb
    Source · Open in Colab
  • The postsubiculum spike claims, on dandiset 000939
    posub_000939.ipynb
    Source · Open in Colab
  • The postsubiculum LFP claims, on dandiset 000939
    posub_lfp_000939.ipynb
    Source · Open in Colab
  • The postsubiculum Isomap ring claims, on dandiset 000939
    posub_ring_000939.ipynb
    Source · Open in Colab

Verification

  • Round 1
    2026-11-10
    Agreed with 17 of 22 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The executed notebooks of commit 2cbcfb2 (reproduce_mehrotra_2024.ipynb, posub_000939.ipynb, posub_lfp_000939.ipynb) with the conclusion cells and the summaries removed, the helper module and the claims file, with the paper. Problems it marked as not affecting a conclusion were also answered: problem 10 (the NREM epochs past the last spike lie outside the home cage epochs, now printed and discussed in the posub data check), problem 11 (the header tables now say which notebook tests each claim) and problem 12 (see fig5e-fc-pmr-onset).
    • fig1b-no-dv-tuning-gradient: the verifier’s outcome was “Not reproduced”. HD information as the Methods formula gives it (bits/s) varies with depth, tau = 0.082, p = 5e-5; speed, AHV, RVL and peak rate behave as claimed (posub cell 23). The bits/spike variant is not significant (p = 0.099), so the outcome turns on the unit. Problem 5: the paper itself filters cells by HD information in bits/spike and cites Duszkiewicz et al. for it; under bits/spike all five correlations come out as the paper reports them; the claims file does not name this as an open detail, a gap in the claims file, not a coding error. It could not check bits/spike against the paper's figures.
    • fig2f-gamma-travels: the verifier’s outcome was “Blocked”. DU-aligned readings: DU differs from 0, but UD also differs (p about 6e-5) wherever it can be tested. Delta-peak readings: DU does not differ (p 0.39 to 0.60). No reading meets the full criterion (lfp cell 7); it gives blocked, methods_underspecified. Problem 2: in A3705 and A3711 the LFP is shorter than the spike record and there is no gamma rise after DU (ratio 1.000 and 1.007, equal to the shifted control), A3708 the same; all three are still used, and their DU delays span the whole search window. Problem 9: the delta-peak readings yield only 0.37-4.76 peaks per minute and are noisy.
    • fig5e-fc-pmr-onset: the verifier’s outcome was “Blocked”. Blocked (too_large), not established. The 66 min estimate assumes reading all 27 archives one after another from a single stream (main cell 15). It asked for the tar member order in one archive and a timing of parallel streams. Problem 12: load_fcx_session would use UPDOWNINtervals, whereas the criterion says SlowWaves events (as Figure5E.py); a deviation if fig5e were run.
    • fig1j-down-resets-hd: the verifier’s outcome was “Blocked”. The block is not supported by the archive: DANDI:000939 holds spikes, HD, wake epochs and UP states, and makeRing.py exists in the code. The claim could be tested.
    • fig1k-hd-stable-at-onset: the verifier’s outcome was “Blocked”. Same data as fig1j; the claim is testable.
  • Round 2
    2026-11-10
    Agreed with 21 of 22 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebooks of commit 34bae66 (reproduce_mehrotra_2024.ipynb, posub_000939.ipynb, posub_lfp_000939.ipynb, posub_ring_000939.ipynb) with their conclusions and summaries, the helper module, the claims file and this record, with the paper. Its text corrections without an outcome change were also made: the 691 s of fig5e (main cell 20), the threshold range of fig5f (main cell 15, now -0.259 to -0.238), and the agreement wording of the posub Summary (the 15 event files share the clock of the spikes by the cross-correlogram peak, while in A3701, A3710 and A3716 only 423 to 769 file DOWN starts lie within 10 ms of a re-detected one). The optional check it suggested for A3708-200317b was added (posub_lfp_000939.ipynb): the LFP rises after neither the re-detected DU (1.045 against 1.048 shifted) nor the event file's UP starts (0.997 against 0.998), so the LFP fits neither stream.
    • fig1b-no-dv-tuning-gradient: the verifier’s outcome was “Not reproduced”. The criterion fixes "the measures as the Methods define them". The printed formula gives bits per second, and under it the claim fails (tau = 0.082, p = 5.1e-5, posub cell 34). The bits-per-spike assumption is stated and plausible; its p = 0.099 and |tau| = 0.034 sit close to the paper's -0.03 and p = 0.13. The claims file does not name the unit as open, a gap the author has correctly sent to a reader. New point: the record leaves the direction of the depth axis unstated; the paper's three non-significant measures are negative and the two significant ones positive, while in the notebook all five are positive with dorsal as positive, so no single axis direction matches all five signs, and the "positively correlated" part rests on reading the paper's axis as dorsal-positive; the opposite direction is said to be reported but is not printed. The quotation "0.2 bits/spike" misquotes the paper's "0.2 bins/spike", and the Figure 1B axis range (-2 to 1, most cells near 0) is not supported by the materials it had (the text has no axis labels, and it could not render the PDF).

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • The wake epochs of the files are taken as the open field exploration for the rate selections, which are shown only to explain the count.rsc-dataset
  • Which units enter is open (criterion readings a and b). Reading (b), putative EX units by trough-to-peak above 0.35 ms and open field rate below 10 Hz, cannot be applied, as the units carry no waveform; only its rate half was run. The outcome rests on reading (a), all sorted units, as Figure5F.py does; the count of entering units (570) equals the n of the Figure 5F legend, which supports it.fig5f-rsc-pmr-onset
  • pynapple 0.11.4 replaces the unpinned pynapple version of the paper's code (a standard choice the criterion allows); compute_eventcorrelogram takes the same arguments.fig5f-rsc-pmr-onset
  • The DOWN and UP states are the paper's event files (Analysis/OutputFiles, commit 4ee34f3), which the criterion names. The event file of A3708-200317b does not share the clock of that session's NWB spikes (population rate inside its DOWN states 454.7 Hz, the same as for intervals shifted by 0.5 s; no shift from -6,000 to +6,000 s brings it below 309 Hz), so its states were re-detected from the spikes with the procedure of detectDOWNs_RSC.py on the file's NREM within the home cage epochs, UP states restricted to NREM as detectDOWNs_PoSub.py does. The outcome rests on this replacement; with the event file as it is, tau is outside the tolerance.fig5c-posub-pmr-onset
  • EX units are the file's is_excitatory flag; the code also requires a gd flag the files do not hold. The counts (1,097 EX, 1,096 entering) match the paper's.fig5c-posub-pmr-onset
  • NREM is the file's sleep_states NREM within the home cage epochs, as detectDOWNs_PoSub.py intersects the sleep scoring with the sleep epochs; it is used only for the re-detection of A3708-200317b.fig5c-posub-pmr-onset
  • Uses the units and PETHs of fig5c-posub-pmr-onset, so it shares its replacement of the states of A3708-200317b.fig5d-isomap-pmr
  • The paper does not define "99th percentile range"; the criterion names two readings, and only (b), 1st to 99th percentile, matches.fig1e-delay-range
  • The states of A3708-200317b are re-detected, as for fig5c-posub-pmr-onset; the UD part of the outcome rests on this.fig1g-dv-sequence-du
  • Position is the rel_y of the unit's peak electrode (12.5 um steps), larger toward dorsal. The rel_y column is described only as "xy coordinate in electrode group"; the direction is from the probe description in the file ("Channels sorted top to bottom of shank"; electrode 0 has the largest rel_y in every session), and Figure1H.py also puts larger depth values dorsal.fig1g-dv-sequence-du
  • The UD timing follows Figure1G.py (last bin above 0.5 between -150 and -5 ms of the PETH around DOWN starts, for units that also cross after +5 ms), with pynapple's correlogram in place of the code's crossCorr.fig1g-dv-sequence-du
  • The code's reading uses all units with a gd flag; the files hold no gd flag, so all units are used.fig1h-ventral-down-longer
  • DOWN and UP states as for fig5c-posub-pmr-onset (A3708-200317b re-detected).fig1h-ventral-down-longer
  • HD information is taken in bits per spike. The Methods print the formula without division by the mean rate (bits per second) but use HD information in bits per spike to select cells for Isomap ("exceeding 0.2 bins/spike", Methods, Isomap Projection and Decoding, citing Duszkiewicz et al.; "bins" is read as a misprint for bits), and the range of Figure 1B (log10 HD info from -2 to 1, no cell beyond about 0.5) fits bits per spike and not bits per second; the outcome rests on this reading.fig1b-no-dv-tuning-gradient
  • Resultant vector length and peak rate are not defined in the Methods; the standard definitions from the 1 degree tuning curve are used. Spikes are counted in the 100 Hz tracking frames.fig1b-no-dv-tuning-gradient
  • Larger rel_y is dorsal: the probe description in the file says "Channels sorted top to bottom of shank", and electrode 0 has the largest rel_y in all 16 sessions.fig1b-no-dv-tuning-gradient
  • The paper's tau is read with dorsal positive, as rel_y here: Figures 1B and S1D to S1F (read from the paper's PDF) plot "D-V pos. (mm)" from 0 at the top to -0.8 at the bottom. "Positively correlated" in the criterion is read in that direction; with ventral positive every tau changes sign (printed), and resultant vector length and peak rate would be negatively correlated.fig1b-no-dv-tuning-gradient
  • The Bayesian decoder is reimplemented in matrix form (Poisson likelihood, uniform prior, as pynapple's decode_1d), with tuning curves in 60 bins from the square arena; the paper gives the bin size of the decoding (50 ms) but not the tuning curve bins (a standard choice).figs1j-dorsal-ventral-same-hd
  • HD cells are the file's is_head_direction flag. A session needs 10 kept bins to enter (a standard choice to avoid empty sessions).figs1j-dorsal-ventral-same-hd
  • The paper has no code for Figure 2. The readings of the criterion were all run (power as the absolute Hilbert transform or the square; DU or delta-peak alignment; two windows). For the UD measure the mirror window, -150 to 0 ms, was added, because the window as written lies after the drop.fig2f-gamma-travels
  • The delta channel is the middle channel of the probe (a standard choice; the Methods name none) and faulty channels are left out. The LFP is downsampled by taking every second sample; filters run forward and backward within each NREM interval.fig2f-gamma-travels
  • A3705-200306, A3708-200317b and A3711-200810b are left out of the main reading: their high gamma power rises after DU by no more than after the same times shifted by 0.5 s (rise over the shifted control 0.02 or less, against 0.053 to 0.357 in the other sessions), so their LFP is not shown to share the clock of the spikes. All 16 sessions are run as a variant.fig2f-gamma-travels
  • The criterion blocks the claim when readings disagree; here every reading fails it, on different parts, so the outcome is not reproduced.fig2f-gamma-travels
  • The main reading leaves out the three sessions whose LFP is not shown to share the clock of the spikes, as for fig2f-gamma-travels; all 16 are run as a variant.figs2d-lfp-spike-agree
  • The outcome rests on the speed definition, the slope of depth on delay, which reproduces the paper's unit speeds; the inverse-slope reading does not.figs2e-speed-similar
  • The LFP side carries the open details of fig2f-gamma-travels, and fig2f-gamma-travels, on which this claim depends, is not reproduced.figs2e-speed-similar
  • The main reading leaves out the three sessions whose LFP is not shown to share the clock of the spikes, as for fig2f-gamma-travels.figs2e-speed-similar
  • The ring follows makeRing.py (commit 4ee34f3): HD cells by the file's is_head_direction flag (the code also needs a gd flag the files lack; the Methods' filter of 0.2 "bins/spike" (read as bits per spike) is not in the code), wake bins of 0.2 s above 2 cm/s, NREM steps of 10 ms with a 50 ms window around UP states longer than 0.5 s, square-root rates, Isomap with 2 components and 200 neighbours, the centre at the projection of an empty bin, and a radius threshold of one third of the mean wake radius.fig1j-down-resets-hd
  • For run time, the random half of the wake bins is capped at 2,500 bins and at most 600 long UP states per session are projected, drawn with a fixed generator per session (a standard choice). Two other draws (seeds 2000 + k and 3000 + k) are run to show the dependence on it.fig1j-down-resets-hd
  • Isomap uses the dense eigen solver in place of the default ARPACK, which starts from an unseeded random vector, so that the ring can come out rotated or reflected differently in each run (a standard choice that makes a run repeat). Each ring is oriented so that its angle increases with head direction in wake (7 of 16 reflected), as the solver's reflection is arbitrary and a reflection negates the angle differences; with the rings as the solver returns them one bin lies outside too.fig1j-down-resets-hd
  • The angle at UD is taken before the start of the DOWN state that ends at the UP state's start; the first post-DU angle is searched 0 to 150 ms after DU. Angle differences are pooled over sessions and the angle at UD is shuffled within each session.fig1j-down-resets-hd
  • The ring and UP states are those of fig1j-down-resets-hd.fig1k-hd-stable-at-onset
  • Assumed: steps below the radius threshold are left out of the cumulative circular variance. The Methods use the threshold "for computing angular direction" and start the slope at 35 ms because the threshold crossing varies between UP states, which implies that angles below the threshold are not used. Keeping them gives p = 0.052, 0.025 and 0.044 over three draws of the ring. The variance is averaged over a session's UP states and the slope taken from 35 to 150 ms (185 to 300 ms for the control); averaging per-UP-state slopes is shown too.fig1k-hd-stable-at-onset
  • The circular variance is 1 - R, scipy.stats.circvar since SciPy 1.8; the older 2 ln(1/R) is shown too, as the paper does not give its SciPy version.fig1k-hd-stable-at-onset
  • Figure5E.py reads buzcode files (SlowWaves events, CellClass, spikes cellinfo) that CRCNS fcx-1 does not hold. The data set's own files stand in for them: UPInts of UPDOWNINtervals.mat for the SlowWaves UP states and EAll of CellIDs.mat for the CellClass EX units. The outcome rests on UPInts; the spike-based ON intervals give a tau outside the tolerance.fig5e-fc-pmr-onset
  • All 27 sessions are used; the paper used 25 (its dataset_DM.list is not in the code repository). The three sessions named by date (20140526_277um, 20140527_421um, 20140528_565um) are taken as one rat, which gives the paper's 11 rats.fig5e-fc-pmr-onset
  • The PETH, PMR and onset delay are those of fig5f-rsc-pmr-onset (Figure5F.py and Figure5E.py are the same procedure), with pynapple 0.11.4.fig5e-fc-pmr-onset

Provenance

Attempt record
mehrotra-2024-01
Paper
Hyperpolarization-Activated Currents Drive Neuronal Activation Sequences in Sleep
Date
2026-10-31
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:000987 (on DANDI)
Version
0.261003.2342 (doi:10.48324/dandi.000987/0.261003.2342)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Other data and code used 4

What the attempt used that is not in the dataset: other data, and the paper’s code. Each is as the attempt’s record describes it.

  • DANDI:000939 A dataset in the registry

    The paper's postsubiculum recordings (units, EX flags, waveform positions, sleep states, epochs, tracking and LFP of the 16 sessions the paper used), for the claims with data elsewhere.

    Source as recorded: DANDI:000939 version 0.261016.2310, doi 10.48324/dandi.000939/0.261016.2310

  • PeyracheLab/MehrotraLevenstein_2023 GitHub

    The paper's analysis code, read for the methods, and its DOWN and UP event files for the 16 PoSub sessions (Analysis/OutputFiles/*.evt.py.dow and *.evt.py.upp), which select the sessions and give the study's DOWN and UP states.

    Source as recorded: https://github.com/PeyracheLab/MehrotraLevenstein_2023 at commit 4ee34f34793c147ac08bf5fffe44ff03d17f8e35

  • crcnsarchive.s3-us-west-2.amazonaws.com

    The rat frontal cortex recordings of Watson et al. 2016 for fig5e-fc-pmr-onset. From each of the 27 archives, streamed, only the members <session>_SStable.mat (spike times), <session>_CellIDs.mat (EX units, EAll) and <session>_UPDOWNINtervals.mat (UP, DOWN, ON and OFF intervals) are read.

    Source as recorded: CRCNS fcx-1, unversioned, https://crcnsarchive.s3-us-west-2.amazonaws.com/fcx-1/live/ (MD5 sums of the 27 archives printed in reproduce_mehrotra_2024.ipynb)

  • DANDI:000056 A dataset in the registry

    Examined only, to decide the block of figs2g-adn-synchronous. The asset list and the units table of the Peyrache et al. 2015 recordings.

    Source as recorded: DANDI:000056 version 0.250624.0430, doi 10.48324/dandi.000056/0.250624.0430

Badges for this paper

Encore: 9 findings reproduced, Mehrotra et al. 2024

It counts the paper’s findings reproduced in full in a current attempt, verified or not. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/mehrotra-2024/"><img src="https://encorescience.org/badge/papers/mehrotra-2024-reproduced.svg" alt="Encore: 9 findings reproduced, Mehrotra et al. 2024"></a>

Or as Markdown:

[![Encore: 9 findings reproduced, Mehrotra et al. 2024](https://encorescience.org/badge/papers/mehrotra-2024-reproduced.svg)](https://encorescience.org/papers/mehrotra-2024/)

The same numbers are in this page’s JSON, under badge (how it is counted).