Papers / Longcore et al. 2024

Relative importance of intensity and spectrum of artificial light at night in disrupting behavior of a nocturnal rodent

Outcomes of 13 claims

  • 10 reproduced
  • 1 partially reproduced
  • 2 not reproduced

Summary: Most of the paper's main findings hold up in this data. Light intensity suppressed nighttime wheel running of mice several times more than color temperature did, warmer light suppressed less, males were less suppressed than females, and SCN cFos counts did not differ between color temperatures. The increase in activity under the dimmest light holds in sign, but none of those means differs from zero. The intensity by color temperature interaction is weaker than reported (p 0.0063 against p < 0.002) and meets the paper's bound only with mouse identity added to the model. Two text statements, on which Tukey-Kramer pairs differed and on the color effect being smallest in the dimmest light, do not match the data.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Longcore et al. (2024) from Dryad dataset t1g1jwtb0 13 Open in Colab

Reproduced10

  • Reproduced

    Light of 0.5 lx and brighter reduced mouse activity during the 1-h exposure at every CCT, except 0.5 lx at 1750 K.

    The mean suppression is above zero for all eight treatments named (0.79 and 2.98 at 0.5 lx and 1950 and 3000…

    Results, paragraph 1; Table 1table1-suppression-0p5-and-above
    From the paper

    Light at 0.5 lx and brighter, except for the 0.5 lx/1750 K treatment, reduced activity of mice ( Table 1 )

    Result

    The mean suppression is above zero for all eight treatments named (0.79 and 2.98 at 0.5 lx and 1950 and 3000 K; 7.02, 12.15 and 30.89 at 5 lx; 53.73, 60.98 and 90.44 at 50 lx). The two 0.5 lx means are close to zero (medians 0.67 and 1.53; one-sample t-test p 0.84 and 0.49), and so is 5 lx at 1750 K (p 0.18). The outcome is judged on the sign of the mean, as the criterion says, so it rests on these three means, which cannot be told from zero. The 50 lx means match the abstract's 91% and 53%.

    Deviations from the paper’s method
    • Means over the mice the file holds for each treatment, 14 at 0.01 lx, 15 at 0.5 lx and 16 at 5 and 50 lx, where the criterion says 16 mice; nine values are not in the dataset.
  • Reproduced

    All three 0.01 lx treatments, and the 0.5 lx/1750 K treatment, increased mouse activity during the exposure.

    The four means are below zero, -12.32, -4.71 and -3.04 at 0.01 lx (1750, 1950, 3000 K) and -2.66 at 0.5 lx and…

    Results, paragraph 1; Table 1table1-increase-0p01
    From the paper

    All 0.01 lx treatments, and the 0.5 lx/1750 K treatment, increased activity during the treatment

    Result

    The four means are below zero, -12.32, -4.71 and -3.04 at 0.01 lx (1750, 1950, 3000 K) and -2.66 at 0.5 lx and 1750 K, over 14, 14, 14 and 15 mice. The abstract's 12.3% and 3% increases match. The outcome is judged on the sign of the mean, as the criterion says, and none of the four differs from zero by a one-sample t-test (p 0.055 at 0.01 lx and 1750 K, 0.32 to 0.67 at the others); at 0.01 lx and 3000 K the median is 0.03 and 7 of 14 mice are below zero. The female means at 0.01 lx and 3000 K (0.78) and 0.5 lx and 1750 K (3.53) are above zero, so at these two treatments the increases come from the males; at 0.01 lx and 1750 K and 1950 K the female means are also below zero (-2.50 and -0.58).

    Deviations from the paper’s method
    • 14 or 15 mice per treatment where the criterion says 16; the missing values are not in the dataset.
  • Reproduced

    At 0.01 lx, CCT had no significant effect on activity, although 1750 K light increased activity more than 3000 K light.

    No CCT pair differs at 0.01 lx (adjusted p 0.63, 0.51 and 0.98; one-way ANOVA p 0.50).

    Results, paragraph 1cct-0p01-not-significant
    From the paper

    at 0.01 lx, CCT was not statistically significant, although 1750 K CCT increased activity more than 3000 K CCT

    Result

    No CCT pair differs at 0.01 lx (adjusted p 0.63, 0.51 and 0.98; one-way ANOVA p 0.50). The mean increase in activity is 12.32% at 1750 K against 3.04% at 3000 K, 9.28 points more.

  • Reproduced

    Over the tested ranges, the effect of illuminance (0.01 to 50 lx) on activity was several times greater than that of CCT (1750 to 3000 K).

    With the identity link the ratio of the scaled illuminance effect to the CCT effect is 3.10 (reading a, lux)…

    Results, paragraph 2; Methods, Photic suppression of nocturnal activity, paragraph 3question to the readereffect-size-illuminance-over-cct
    From the paper

    The influence of illuminance on mouse activity across the 0.01-50 lx range was several times greater than the effect of CCT across the 1750-3000 K range

    Result

    With the identity link the ratio of the scaled illuminance effect to the CCT effect is 3.10 (reading a, lux), 3.72 (b, lux), 3.20 (a, log10 lux) and 3.84 (b, log10 lux); the scaled illuminance estimate is 34.1 or 35.2 points and the CCT effect 11.0 (largest level parameter, 3000 K) or 9.2 (continuous). With the log link the ratios are 2.89 and 3.62 with log10 lux and 0.80 and 1.81 with lux. The abstract's 3.6 is within the range. The claim depends on glm-illuminance-cct-interaction, partially reproduced; the effect sizes do not use its interaction test.

  • Reproduced

    At equal illuminance in lux, lower CCT light suppressed mouse activity less than higher CCT light.

    The 1750 K mean is below the 3000 K mean at 0.5 lx (-2.66 against 2.98), 5 lx (7.02 against 30.89) and 50 lx…

    Discussion, paragraph 1; Table 1; Figure 2Alower-cct-less-suppression
    From the paper

    a lower CCT reduced the effect of equal intensity light (as perceived by humans) on an organism more sensitive to shorter wavelengths of light than humans when the intensity is measured in lux

    Result

    The 1750 K mean is below the 3000 K mean at 0.5 lx (-2.66 against 2.98), 5 lx (7.02 against 30.89) and 50 lx (53.73 against 90.44); 1950 K lies between. Mouse by mouse, 1750 K is below 3000 K in 9 of 15 mice at 0.5 lx (paired Wilcoxon p 0.33), 15 of 16 at 5 lx and 16 of 16 at 50 lx.

  • Reproduced

    Adding sex, or mouse identity, to the GLM improved it; the model with mouse identity had the lowest AICc (1608.1), then the model with sex (1624.6), then the model with neither (1640.3).

    Under the identity link with illuminance in lux, the AICc is 1612.3 with mouse identity, 1628.26 with sex and…

    Results, paragraph 3; Methods, Photic suppression of nocturnal activity, paragraph 3question to the readeraicc-individual-sex
    From the paper

    Both sex and mouse individual added explanatory power to the model, with the model including individuals having the lowest AICc (1608.1), compared with sex (1624.6) or without either variable (1640.3)

    Result

    Under the identity link with illuminance in lux, the AICc is 1612.3 with mouse identity, 1628.26 with sex and 1643.9 with neither; the order holds and the differences, 15.64 and 15.96, are within 15.7 +/- 1.6 and 16.5 +/- 1.7. The values are 3.6 to 4.2 above the paper's; not counting the scale lowers them by 2.2 to 2.6 and leaves the differences within tolerance. No other reading matches (log link and lux, order fails; log link and log10 lux, differences 6.49 and 3.29; identity link and log10 lux, order fails). The source of the offset is not settled; the paper's n of 192 cannot be rerun, as nine values are not in the dataset, and JMP's parameter count for AICc is not stated.

    Deviations from the paper’s method
    • AICc counts the scale as a parameter, the usual count for a normal model; JMP's count is not stated, and the other count is shown.
  • Reproduced

    In the model including sex, males' activity was suppressed significantly less by light at night than females'.

    With the identity link and lux, the female parameter is +6.32 (males 12.6 points below females)…

    Results, paragraph 3; Figure 2Csex-males-less-suppressed
    From the paper

    From the model including sex, activity of males was suppressed significantly less than females by light at night ( P <0.0001; Fig. 2C )

    Reported statistics
    • generalized linear model effect test, sex, p < 10⁻⁴ (n = 8 males and 8 females)
    Result

    With the identity link and lux, the female parameter is +6.32 (males 12.6 points below females), likelihood-ratio p 2.4e-05 and Wald p 2.2e-05. Males are lower under every reading; with log10 lux and the identity link p is 0.0003, and with the log link 0.003 to 0.007. The test treats each mouse-by-treatment value as independent; one value per mouse (8 against 8), a Mann-Whitney test gives p 0.083.

  • Reproduced

    From the model with sex, at 0.01 lx and 1750 K male activity increased by 9.3% while female activity was suppressed by 3.4%; at 50 lx and 3000 K male activity was suppressed by 85.7% and female activity by 98.3%.

    Under the identity link with lux the predictions are -10.90 (males, 0.01 lx and 1750 K), 1.75 (females), 85.57…

    From the paper

    For example, at the lowest intensity (0.01 lx) and CCT, male activity was increased by 9.3% (95% CI=3.8-14.7% increase), whereas female activity was suppressed by 3.4% (95% CI=2.1% increase to 8.9% decrease). At the maximum intensity and CCT, male activity was suppressed by 85.7% (95% CI=75.6-95.7%), whereas female activity was suppressed by 98.3% (95% CI=88.3-108.3%)

    Reported statistics
    • males, 0.01 lx and 1750 K, as increase in activity: 95% CI 3.8 to 14.7 percent increase
    • females, 0.01 lx and 1750 K, as suppression: 95% CI -2.1 to 8.9 percent
    • males, 50 lx and 3000 K: 95% CI 75.6 to 95.7 percent
    • females, 50 lx and 3000 K: 95% CI 88.3 to 108.3 percent
    Result

    Under the identity link with lux the predictions are -10.90 (males, 0.01 lx and 1750 K), 1.75 (females), 85.57 and 98.22 (males and females, 50 lx and 3000 K), all within tolerance. The log link puts three within tolerance under either scale; it cannot predict the negative male value. With log10 lux and the identity link none is within tolerance. The raw means by sex (-22.14, -2.50, 85.59, 95.28) put the two 0.01 lx values outside tolerance. The 95% intervals here (t with 183 - 7 = 176 df, printed) are wider than the paper's at 0.01 lx (-17.7 to -4.1 against the paper's -14.7 to -3.8).

  • Reproduced

    Mice varied greatly in their response, individual effects ranging from up to 27.9 percentage points less suppression to 21.5 percentage points more suppression than average.

    Under reading (a), identity link and lux, the mouse parameters range from -27.86 (6FC2, P6, less suppression)…

    Results, paragraph 3; Figure 2Bquestion to the readerindividual-variation
    From the paper

    The model that included the animal identification number ( Fig. 2B ) revealed a great variability in activity among the mice, with individual mice ranging from being much more active regardless of light treatment (up to 27.9 percentage points less suppression; 95% CI=18.3-37.4) to being substantially more affected (21.5 percentage points increased suppression; 95% CI=8.1-34.8)

    Reported statistics
    • most active mouse, less suppression: 95% CI 18.3 to 37.4 percentage points
    • most affected mouse, more suppression: 95% CI 8.1 to 34.8 percentage points
    Result

    Under reading (a), identity link and lux, the mouse parameters range from -27.86 (6FC2, P6, less suppression) to +21.46 (6FC1, P2), the paper's 27.9 and 21.5; 95% intervals -38.0 to -17.7 and 7.3 to 35.7 against the paper's 18.3 to 37.4 and 8.1 to 34.8. Reading (b) gives the same values with the identity link; with log10 lux the extremes are -27.21 and 18.24, also within tolerance; with the log link reading (b) gives -14.7 and 6.8, outside. Mouse 6FC1, P2 lacks its 0.01 and 0.5 lx values; its raw mean is 38.3 points above the mean of mice for that reason, and the model's parameter accounts for it.

  • Reproduced

    The number of cFos-positive cells in the SCN after 1 h of 50 lx light did not differ between 1950 K (123.7 +/- 17.89 s.d.) and 3000 K (113.4 +/- 8.22 s.d.) light.

    The unpaired t-test gives t(10) = 0.9409 and p = 0.3689, the paper's values; Welch's test gives p 0.3692.

    Results, paragraph 4; Figure 3Bquestion to the readercfos-no-cct-difference
    From the paper

    No differences were observed in the number of cFos positive cells in the SCN of WT mice exposed to either 1950 K (123.7±17.89 s.d.) or 3000 K (113.4±8.22 s.d.) light (unpaired t -test ... t 10 =0.9409, P <0.3689)

    Reported statistics
    • two-tailed unpaired t-test, t(10) = 0.9409, p < 0.3689 (n = 6 mice per light (3 per sex))
    Result

    The unpaired t-test gives t(10) = 0.9409 and p = 0.3689, the paper's values; Welch's test gives p 0.3692. Means 123.74 (s.d. 17.89) and 113.40 (s.d. 20.13), difference 10.35 cells. The paper's 3000 K spread of 8.22 is the s.e.m. of these values, not the s.d., which is why the claims file found its means and s.d. inconsistent with its t. The claims file's 8.22 tolerance on the 3000 K mean rests on the same reading; with the s.d. of 20.13 the mean is still within tolerance, so the outcome does not change. Asked in questions/longcore-2024.yaml.

    Deviations from the paper’s method
    • The file holds one value per animal, already combined over sections, sides and observers, so the claims file's reading (mean over observers, each observer as a variant) cannot be run; the deposited per-animal values are used.

Partially reproduced1

  • Partially reproduced

    In a generalized linear model of suppression, illuminance, CCT and their interaction each contributed significantly, and the whole model was significant.

    No reading meets the interaction bound of p < 0.002; the smallest interaction p is 0.0063 (identity link…

    Results, paragraph 2; Methods, Photic suppression of nocturnal activity, paragraph 3question to the readerglm-illuminance-cct-interaction
    From the paper

    Mouse activity was associated with light conditions in a generalized linear model ( P <0.001), with significant contributions of illuminance ( P <0.0001), spectrum ( P <0.0001) and the interaction term ( P <0.002)

    Reported statistics
    • whole model: generalized linear model, normal distribution, log link, p < 0.001
    • illuminance: generalized linear model effect test, p < 10⁻⁴
    • CCT (spectrum): generalized linear model effect test, p < 10⁻⁴
    • CCT x illuminance: generalized linear model effect test, p < 0.002
    Result

    No reading meets the interaction bound of p < 0.002; the smallest interaction p is 0.0063 (identity link, illuminance in lux, likelihood ratio; Wald 0.0065). Under that reading the whole model has p 1.6e-43, illuminance p < 1e-44 and CCT p 2.1e-06 (0.034 with illuminance not centered in the crossing), so all three terms have p < 0.05, the partial criterion. With illuminance in log10 lux and the identity link the interaction p is 0.026 to 0.027. With the log link the Methods state, the interaction is not significant under any reading (smallest likelihood-ratio p 0.082). The log-link fit with lux leaves its parameters undetermined (fitted means near zero at 1750 K up to 5 lx, condition number of J'J 3e9, standard errors up to 43 on the log scale), so its Wald tests (p 0.89 for illuminance) and intervals are not usable; the likelihood-ratio tests do not depend on them. All four log-link fits reached the same sum of squares from four starts. In the model with mouse identity added (identity link, lux) every bound is met (interaction p 0.0007 likelihood ratio, 0.0013 Wald; CCT 1.1e-08; illuminance 4.6e-54), and in the model with sex added the interaction p is 0.0038. The criterion names the model without either, so the outcome stays partial; whether the paper's tests come from the model with mouse identity is asked in questions/longcore-2024.yaml.

    Deviations from the paper’s method
    • Fitted in Python (least squares for the identity link, a trust-region solver for the log link), not JMP. Terms coded as JMP's Fit Model codes them by default (effect coding, illuminance centered in the crossing); the uncentered fit is shown and changes only the CCT main-effect p, not the outcome.
    • The whole-model test is a likelihood ratio against the intercept-only model; the paper does not name it.

Not reproduced2

  • Not reproduced

    In Tukey-Kramer comparisons within color temperatures, the effect of illuminance on activity was significantly greater only for 50 lx at 1750 K.

    Neither reading matches. Reading (a), within each CCT, finds 50 lx different from every lower illuminance at…

    Results, paragraph 1; Methods, Photic suppression of nocturnal activity, paragraph 3tukey-illuminance-within-cct
    From the paper

    Within color temperatures, the effect of illuminance on mouse activity was only significantly greater for 50 lx at 1750 K

    Result

    Neither reading matches. Reading (a), within each CCT, finds 50 lx different from every lower illuminance at all three CCTs (adjusted p < 0.001), and at 3000 K also 5 lx against 0.01 and 0.5 lx (p < 0.001, 0.0003). Reading (b), within each illuminance, finds CCTs different at 5 lx and at 50 lx, in both cases 3000 K against 1750 K and against 1950 K (50 lx differences 36.7 and 29.5 points, p 0.0003 and 0.0035), and not 1750 against 1950 K (7.2 points, p 0.68). One Tukey-Kramer family over all twelve treatments gives the same within-CCT pairs, and within illuminances 3000 K against 1750 K at 5 lx (p 0.0498) and 3000 K against both at 50 lx.

    Deviations from the paper’s method
    • One Tukey-Kramer family per CCT (reading a) or per illuminance (reading b), from the Methods ("testing for significant differences for each while holding the other constant"); a single family over twelve treatments is shown as a variant and gives the same conclusion.
  • Not reproduced

    The influence of CCT on activity was smallest at the lowest illuminance and grew as illuminance increased, as shown by the significant CCT x illuminance interaction.

    The spread of mean suppression across CCTs is 9.28 points at 0.01 lx, 5.64 at 0.5 lx, 23.87 at 5 lx and 36.71…

    Results, paragraph 2; Discussion, paragraph 5verifier disagreed at firstquestion to the readercct-effect-grows-with-intensity
    From the paper

    with the influence of CCT decreasing at the lowest light strength

    Result

    The spread of mean suppression across CCTs is 9.28 points at 0.01 lx, 5.64 at 0.5 lx, 23.87 at 5 lx and 36.71 at 50 lx. The spread at 50 lx is larger than at 0.01 lx and the interaction is significant at 0.05 (p 0.0063, identity link and lux), but the smallest spread is at 0.5 lx, not 0.01 lx, so the first condition of the criterion fails, and the criterion defines no partial outcome. The spread grows from the two lower illuminances to the two higher. By sex the spread at 0.01 lx is 3.29 (F) and 15.28 (M). The GLM variant gives spreads smallest at 0.01 lx under every reading (identity and lux 11.95, 12.20, 14.51, 37.58), but a model linear in illuminance for each CCT makes the spread grow almost by construction, so the variant carries little weight. The interaction does not reach the paper's p < 0.002 (claim glm-illuminance-cct-interaction). Whether the criterion should use the model's spread is asked in questions/longcore-2024.yaml.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Paper inconsistentThe Methods state a generalized linear model with a normal distribution and a log link, but the reported results fit an identity link. The paper reports a negative predicted suppression for males (9.3% increase) with a 95% interval symmetric about it, which a log link cannot give, and the identity-link model with illuminance in lux reproduces the reported AICc differences (15.6 and 16.0 against 15.7 and 16.5), the four sex predictions and the extreme mouse effects (-27.9 and +21.5), which the log-link models do not. The abstract also calls the analysis a multiple linear regression. Question for the authors, which link and which scale of illuminance did the JMP models use?#
  • Paper inconsistentThe Results give the 3000 K cFos count as 113.4 +/- 8.22 s.d.; the deposited values have s.d. 20.13 and s.e.m. 8.22, and the reported t(10) = 0.9409 follows from the s.d. of 20.13. The 1950 K value (17.89) is an s.d., so the two groups are summarized with different measures.#
  • Methods not availableThe Results say that within color temperatures only 50 lx at 1750 K differed significantly by Tukey-Kramer comparisons; on the deposited data 50 lx differs from every lower illuminance at all three CCTs, and among CCTs it is 3000 K that differs from the others at 5 and 50 lx. The paper does not list the pairs it found, so the sentence cannot be traced to a comparison. Question for the authors, which comparisons does the sentence describe?#

Questions about the claims 5

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • openasked 2026-11-25about cfos-no-cct-difference

    The claims file takes the paper's 8.22 for the 3000 K group as an s.d., uses it as the tolerance on that mean, and notes that the paper's means and s.d. give t near 1.28, not 0.9409. The deposited values give s.d. 20.13 and s.e.m. 8.22 for that group, and t(10) = 0.9409 with the s.d. of 20.13. Should the claims file read 8.22 as an s.e.m., drop the remark about t near 1.28, and set the tolerance on the 3000 K mean from the s.d.?

    Passage. No differences were observed in the number of cFos positive cells in the SCN of WT mice exposed to either 1950 K (123.7±17.89 s.d.) or 3000 K (113.4±8.22 s.d.) light (unpaired t-test, t10=0.9409, P<0.3689). (Results, paragraph 4)

    Why it matters. The outcome rests on the t-test and is the same either way (the mean, 113.40, is within both tolerances). The question is whether the claims file's reasoning and the tolerance rest on an error in the paper.

    No reader has answered it yet.
  • The opening comment keeps the log link the Methods state as reading (a) and the identity link as reading (b). The abstract calls the analysis a multiple linear regression, and the identity link with illuminance in lux reproduces the paper's AICc differences, sex predictions, their intervals and the extreme mouse effects, which the log link does not. Should the claims file note the abstract's wording and treat the identity link as the paper's model?

    Passage. Multiple linear regression confirmed the influence of both CCT and intensity on changes in activity, with the scaled effect size of intensity 3.6 times greater than that of CCT. (Abstract); we built a generalized linear model with a normal distribution and log link function (Methods, Photic suppression of nocturnal activity, paragraph 3)

    Why it matters. The criteria accept either link, so no outcome changes. A reader of the claims file would see which reading the paper's numbers support.

    No reader has answered it yet.
  • openasked 2026-11-25about glm-illuminance-cct-interaction

    The criterion tests the model with CCT, illuminance and their interaction only. Could the paper's effect tests (P < 0.001, < 0.0001, < 0.0001, < 0.002) come from the model with mouse identity added, which the next paragraph reports? In this attempt that model, with the identity link and lux, meets every bound (interaction p 0.0007 likelihood ratio, 0.0013 Wald); the model without either reaches p 0.0063 for the interaction.

    Passage. Mouse activity was associated with light conditions in a generalized linear model (P <0.001), with significant contributions of illuminance (P <0.0001), spectrum (P <0.0001) and the interaction term (P <0.002). (Results, paragraph 2); Sex and mouse ID were included in separate models as additional explanatory factors (Methods, paragraph 3)

    Why it matters. Under the criterion as written the claim is partially reproduced; with the model with mouse identity among its readings it would be reproduced.

    No reader has answered it yet.
  • openasked 2026-11-25about cct-effect-grows-with-intensity

    The criterion measures the influence of CCT at each illuminance by the raw spread of the CCT means, a choice of the claims file. The paper's sentence follows its GLM result and ties the effect to the interaction term, so it may refer to the model. Should the criterion use the spread of the GLM's predicted CCT means, now a variant?

    Passage. The influence of illuminance on mouse activity across the 0.01-50 lx range was several times greater than the effect of CCT across the 1750-3000 K range, with the influence of CCT decreasing at the lowest light strength. (Results, paragraph 2); spectrum becomes increasingly important as intensity increases, as shown by the significant interaction term between CCT and intensity (Discussion)

    Why it matters. The raw spread is 9.28 at 0.01 lx and 5.64 at 0.5 lx, so it is not smallest at 0.01 lx and the claim is not reproduced. The GLM spread is smallest at 0.01 lx under every reading, though a model linear in illuminance for each CCT makes it grow almost by construction, and the interaction p (0.0063) is above the paper's bound.

    No reader has answered it yet.
  • openasked 2026-11-25about cct-effect-grows-with-intensity

    The verifier of round 2 reports that the claim's "grew as illuminance increased, as shown by the significant CCT x illuminance interaction" goes beyond the Results sentence, which says only that the influence of CCT decreased at the lowest light strength. The claim also cites the Discussion, which says spectrum becomes increasingly important as intensity increases, as shown by the interaction term. Should the statement rest on the Results sentence alone, or is the Discussion sentence the paper's finding as the claim states it?

    Passage. with the influence of CCT decreasing at the lowest light strength (Results, paragraph 2); However, spectrum becomes increasingly important as intensity increases, as shown by the significant interaction term between CCT and intensity. (Discussion, paragraph 5)

    Why it matters. The criterion's condition that the spread be smallest at 0.01 lx follows the Results sentence and decides the outcome, so no outcome changes. The question is whether the statement says more than the paper's result.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Light intensity and spectrum in suppressing mouse activity (Longcore et al. 2024)

Tests the findings of Longcore, Villanueva, Nguyen-Ngo, Ghiani, Harrison and Colwell (2024) on Dryad dataset t1g1jwtb0, which holds the percent suppression of wheel running of 16 mice under twelve combinations of illuminance and color temperature, per-animal cFos counts in the SCN after 50 lx light at two color temperatures, and the lamps' spectra. It recomputes the treatment means, the Tukey-Kramer comparisons, the generalized linear models with sex and mouse identity, and the cFos t-test. All files

Environment: Python 3.13, 13 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-25
    Agreed with 12 of 13 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The first executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper's full text (PMC11418196). The verifier checked the SHA-256 values against Dryad's file list for version 300765 and tested fit, design and effect_codes against statsmodels on synthetic data. It had no attempt record and took the claims from the claims file.
    • cct-effect-grows-with-intensity: the verifier’s outcome was “Not reproduced”. The raw CCT spread at 0.01 lx (9.28) is larger than at 0.5 lx (5.64), so the criterion's "smallest at 0.01 lx" fails, although the interaction is significant (p=0.0063). The GLM-predicted spreads do grow monotonically, but with a linear interaction term that follows almost automatically, so it gives them little weight. Problem 3, the raw spread is the claims author's own choice; the paper's sentence follows the GLM result, so it may refer to the model. It kept the criterion as written.
  • Round 2
    2026-11-25
    Agreed with 13 of 13 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The full executed notebook after the round-1 revision, with its conclusions and summary, the helper module, the claims file, this attempt record, the questions file and the paper's full text.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • Means over the mice the file holds for each treatment, 14 at 0.01 lx, 15 at 0.5 lx and 16 at 5 and 50 lx, where the criterion says 16 mice; nine values are not in the dataset.table1-suppression-0p5-and-above
  • 14 or 15 mice per treatment where the criterion says 16; the missing values are not in the dataset.table1-increase-0p01
  • One Tukey-Kramer family per CCT (reading a) or per illuminance (reading b), from the Methods ("testing for significant differences for each while holding the other constant"); a single family over twelve treatments is shown as a variant and gives the same conclusion.tukey-illuminance-within-cct
  • Fitted in Python (least squares for the identity link, a trust-region solver for the log link), not JMP. Terms coded as JMP's Fit Model codes them by default (effect coding, illuminance centered in the crossing); the uncentered fit is shown and changes only the CCT main-effect p, not the outcome.glm-illuminance-cct-interaction
  • The whole-model test is a likelihood ratio against the intercept-only model; the paper does not name it.glm-illuminance-cct-interaction
  • AICc counts the scale as a parameter, the usual count for a normal model; JMP's count is not stated, and the other count is shown.aicc-individual-sex
  • The file holds one value per animal, already combined over sections, sides and observers, so the claims file's reading (mean over observers, each observer as a variant) cannot be run; the deposited per-animal values are used.cfos-no-cct-difference

Provenance

Attempt record
longcore-2024-01
Paper
10.1242/jeb.247235
Date
2026-11-25
Made by
An agent, run by CatalystNeuro
Dataset
DRYAD:t1g1jwtb0 (on DRYAD)
Version
300765 (doi:10.5061/dryad.t1g1jwtb0)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-19

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Badges for this paper

Encore: 10 findings reproduced, Longcore et al. 2024

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/longcore-2024/"><img src="https://encorescience.org/badge/papers/longcore-2024.svg" alt="Encore: 10 findings reproduced, Longcore et al. 2024"></a>

Or as Markdown:

[![Encore: 10 findings reproduced, Longcore et al. 2024](https://encorescience.org/badge/papers/longcore-2024.svg)](https://encorescience.org/papers/longcore-2024/)

The same numbers are in this page’s JSON, under badge (how it is counted).