Datasets
Not attempted yet. These are the claims read from the paper, which an attempt will test; next in the pipeline: attempt.
Claims 38
From the paper Adaptation to Stimulus Contrast and Correlations during Natural Visual Stimulation · claims file · checked 2026-11-19: ready
The 15 min movie analyses include 68 LGN cells whose RF peak is at least ten times the noise, 44 ON-center (19 X, 19 Y, 6 unclassified) and 24 OFF-center (11 X, 8 Y, 5 unclassified); 26 of them have the 90 s repeats and 31 have white noise and the 12 s repeats.
From the paper
This sample included 68 cells... 44 cells that were ON-center (19 X cells, 19 Y cells, and 6 cells that were not classified ... and 24 cells that were OFF-center (11 X cells, 8 Y cells, and 5 cells that were not classified). For a subset of 26 cells ... For a subset of 31 cells
Criterion
Inclusion as the Methods give it, the RF peak (largest absolute value of the HC and of the LC movie RF) at least ten times the SD of an RF estimated from shuffled responses. Open is whether a cell must pass at both contrasts or at either; readings (a) both, (b) either. The counts are reported by ON/OFF and X/Y where the dataset labels them.
Across the 31 cells with all four stimuli, mean firing rates are higher at high than at low contrast for both natural movies (10.5 against 6.5 Hz) and white noise (8.2 against 5.7 Hz).
From the paper
the mean firing rates during HC stimulation (NS, 10.5 ± 4.8 Hz; WN, 8.2 ± 3.7 Hz) were significantly higher than those during LC stimulation (NS, 6.5 ± 3.4 Hz; WN, 5.7 ± 3.1 Hz) for both NS and WN (paired t tests, p < 0.001)
Criterion
Tolerances are the across-cell SDs the paper gives. Mean rate per cell and stimulus over its whole presentation, under readings P2 (a) and (b). Reproduced when, under one reading, all four means are within tolerance and paired t tests of HC against LC give p < 0.001 with HC higher for NS and for WN.
Mean firing rates to low-contrast natural movies and low-contrast white noise do not differ across the 31 cells.
From the paper
the mean firing rates for these stimuli across the sample of 31 cells were not significantly different (paired t tests, p > 0.2)
Criterion
A claim of absence. Paired t test of LC NS against LC WN mean rates over the 31 cells, rates as in firing-rate-contrast. Reproduced when p > 0.05 (P3); the p-value and the mean difference are reported, and whether p > 0.2.
LN models fitted from the 15 min movie predict responses to a novel 90 s movie segment with correlation coefficients of 0.70 at high and 0.76 at low contrast (26 cells, 8 ms bins).
From the paper
the LN model provided accurate predictions of the LGN ... responses to novel natural stimuli, with correlation coefficients of 0.7 ± 0.07 for HC and 0.76 ± 0.07 for LC (for firing rate in 8 ms bins)
Criterion
Tolerances are the across-cell SDs given. RF and NL of each contrast from the 15 min movie as in the Methods; the prediction is the NL applied to the filtered 90 s stimulus. The paper does not say what the prediction is correlated with; readings (a) the response averaged over the 24 repeats, (b) each repeat, averaged over repeats. Reproduced when, under one reading, both means are within tolerance.
A decrease in contrast has no significant effect on the width of the spatial RF center, for natural movies (68 cells) or white noise (31 cells).
From the paper
decreases in contrast had no significant effect on the width of the spatial RF, as shown in Figure 3B
Criterion
A claim of absence. Spatial width as in the Methods (DoG fit at peak latency, full width at half peak). Paired t tests of HC against LC, NS over the 68 cells and WN over the 31. Reproduced when neither gives p < 0.05 (P3); the mean change is reported, and the 31-cell NS test is shown as a variant.
A decrease in correlations (low-contrast natural movie to low-contrast white noise) decreases the width of the spatial RF center by 20% on average (31 cells).
From the paper
a decrease in correlations caused an average decrease of 20% in the width of the spatial RF center
Criterion
The statistics entry is read from the Figure 3 legend, whose only marked level is ***p < 0.001; the panel itself was not read. Paired t test of LC NS against LC WN widths over the 31 cells. Reproduced when p < 0.001 with WN narrower and the decrease is within tolerance under reading P1 (a) or (b); partially reproduced when the test holds and the decrease is outside tolerance.
A decrease in contrast decreases the relative strength of the RF surround by 17% for natural movies and 18% for white noise.
From the paper
The relative strength of the surround was decreased by a decrease in contrast during both NS (17%) and WN (18%) stimulation
Criterion
Surround/center ratio as in the Methods. The surround profile's peak is open; readings (a) its largest absolute value, (b) its extreme of the sign opposite to the center. Paired t tests of HC against LC, NS over 68 cells, WN over 31 (Figure 3 legend, ***p < 0.001). Reproduced when both tests give p < 0.001 with LC lower and both decreases are within tolerance under one reading of P1 and of the peak; partially reproduced when the tests hold and the sizes do not.
A decrease in correlations decreases the relative strength of the RF surround by 34%.
From the paper
as well as by ... a decrease in correlations (34%)
Criterion
As fig3c-surround-contrast, for LC NS against LC WN over the 31 cells.
A decrease in contrast widens the temporal profile of the RF center (slower dynamics) by 16% for natural movies and 15% for white noise.
From the paper
the width of the temporal profile of the RF center was increased by a decrease in contrast during both NS (16%) and WN (15%) stimulation
Criterion
Temporal width as in the Methods, on the 8 ms grid (P6). Paired t tests of HC against LC (Figure 3 legend, ***p < 0.001). Reproduced when both give p < 0.001 with LC wider and both increases are within tolerance under reading P1 (a) or (b); partially reproduced when the tests hold and the sizes do not.
A decrease in correlations widens the temporal profile of the RF center by 15%.
From the paper
as well as by a decrease in correlations (15%)
Criterion
As fig3d-temporal-width-contrast, for LC NS against LC WN over the 31 cells.
Across cells and the HC and LC natural movie conditions, the relative surround strength and the temporal width of the RF center are negatively correlated (r = -0.5, p < 0.001).
From the paper
the correlation coefficient between the relative strength of the surround and the width of the temporal profile of the RF center during HC and LC natural stimulation was
Criterion
The sign of -0.5 is printed as a garbled glyph in the text; the context (stronger surround with faster dynamics) and the Discussion fix it as negative. Pearson correlation of the two properties over all cell and condition values pooled (the 68 cells at HC and at LC), as the Supplementary Figure 1 legend describes for pooled values. Reproduced when r is within tolerance and p < 0.001.
Changes in RF and NL properties are correlated with each other across stimulus conditions; every pairwise correlation of the properties that adapt significantly has p < 0.001, except surround/center ratio against temporal width for contrast during white noise (p = 0.06).
From the paper
All correlation coefficients had p < 0.001, except for that between surround/center ratio and temporal width for contrast adaptation during WN stimulation, which has p = 0.06
Criterion
Pearson correlation for each pair of the properties with significant adaptation (surround/center ratio, temporal width, gain, normalized offset, plus spatial width and offset in the comparisons where they adapt), within each comparison (contrast in NS, contrast in WN, correlations), values from both conditions of the comparison pooled, as the legend says. Which pairs and comparisons the figure plots could not be read from the text; readings (a) the four properties that adapt in all three comparisons, (b) every property with a significant change in that comparison. Reproduced when, under one reading, all pairs but the named one have p < 0.001 and the named one has p > 0.001; partially reproduced when at least three quarters do.
A decrease in contrast increases the gain of the nonlinearity by 89% for natural movies and 148% for white noise.
From the paper
The gain was increased by a decrease in contrast during both NS (89%) and WN (148%) stimulation
Criterion
Gain from the half-wave rectifier fit (P4) of the NL estimated as in the Methods. Paired t tests of HC against LC (Figure 4 legend, ***p < 0.001). Reproduced when both give p < 0.001 with LC higher and both increases are within tolerance under one reading of P1 (a or b, and for WN also c); partially reproduced when the tests hold and the sizes do not.
A decrease in correlations increases the gain of the nonlinearity by 296%.
From the paper
as well as by a decrease in correlations (296%), as shown in Figure 4B
Criterion
As fig4b-gain-contrast, for LC NS against LC WN over the 31 cells, under P1 (a), (b) or (c).
A decrease in contrast decreases the (absolute) offset of the nonlinearity by 56% for natural movies and 59% for white noise.
From the paper
the offset was decreased by a decrease in contrast during both NS (56%) and WN (59%) stimulation
Criterion
Offset q from the half-wave rectifier fit (P4), adjusted per animal (P5). Paired t tests of HC against LC (Figure 4 legend, ***p < 0.001). Reproduced when both give p < 0.001 with LC lower and both decreases are within tolerance under reading P1 (a) or (b); partially reproduced when the tests hold and the sizes do not. The unadjusted q is shown as a variant.
A decrease in correlations has no effect on the (absolute) offset of the nonlinearity.
From the paper
The offset adapted to a change in contrast, but not to a change in correlations
Criterion
A claim of absence. Paired t test of LC NS against LC WN offsets (adjusted per animal, P5) over the 31 cells. Reproduced when p >= 0.05 (P3); the mean change is reported.
A decrease in contrast increases the normalized offset (selectivity) by 14% for natural movies and 24% for white noise.
From the paper
the normalized offset was increased by a decrease in contrast during both NS (14%) and WN (24%) stimulation
Criterion
Normalized offset is the adjusted q over the SD of the filtered stimulus of the same segment. Paired t tests of HC against LC (Figure 4 legend, ***p < 0.001). Reproduced when both give p < 0.001 with LC higher and both increases are within tolerance under reading P1 (a) or (b); partially reproduced when the tests hold and the sizes do not.
A decrease in correlations increases the normalized offset by 90%.
From the paper
as well as by a decrease in correlations (90%)
Criterion
As fig4d-normalized-offset-contrast, for LC NS against LC WN over the 31 cells, under P1 (a) or (b).
Within a single presentation of the high-contrast movie, the contrast inside a cell's RF varies over time (0.27 to 0.43 over a 150 s segment for an example OFF-center Y cell), and RFs and NLs estimated from the periods in the top and bottom thirds of all its values show the same changes in surround, temporal dynamics, gain and offset as the HC and LC comparison; for a second cell (OFF-center X) whose RF contrast is higher and varies over a smaller range, they are nearly identical.
From the paper
We estimated separate RFs and NLs for those periods during which the contrast within the RF was within either the top or bottom third of all values for this cell ... the changes evident in the surround strength and temporal dynamics of the RF and gain and offset of the NL are similar to those described above
Criterion
The paper shows two example cells and no sample statistic; the example cells cannot be identified from the text. The measure is "the temporal contrast averaged over the spatial RF" (Figure 5A legend); how it is computed is open, readings (a) per frame, the RMS contrast over the pixels of the spatial RF, (b) per RF pixel, the RMS contrast of its intensity over time in a sliding window (length not given), averaged over the RF pixels; under each, with and without weighting by the RF's spatial profile. The range is read over a 150 s segment of the HC movie and the thirds over the whole 15 min movie (Figure 5A legend). RFs and NLs of the top and bottom thirds as in the Methods. Reproduced when at least one OFF-center Y cell has a 150 s segment whose contrast range is within tolerance and its top-third RF and NL show a higher surround/center ratio, a narrower temporal width, a lower gain and a higher offset than its bottom-third ones. The share of all cells showing these four directions is reported.
A decrease in contrast decreases response reliability by 54% for natural movies and 74% for white noise (31 cells).
From the paper
a decrease in contrast during natural stimulation caused an average decrease of 54% in reliability, as shown in Figure 6A. Similar decreases in reliability were caused by a decrease in contrast during white noise stimulation (74%)
Criterion
Reliability as in the Methods from the 120 repeats of each 12 s segment, 8 ms bins, under readings P8 (a) and (b). The Figure 6 legend marks differences at **p < 0.01 or ***p < 0.001 and which bar carries which was not read, so p < 0.01 is the level judged. Reproduced when paired t tests of HC against LC give p < 0.01 with LC lower for NS and WN and both decreases are within tolerance under one reading of P1 and P8; partially reproduced when the tests hold and the sizes do not.
A decrease in correlations decreases response reliability by 68%.
From the paper
and by a decrease in correlations (68%)
Criterion
As fig6a-reliability-contrast, for LC NS against LC WN.
A decrease in contrast causes only a small decrease in sparseness for natural movies (4%) and a larger one for white noise (16%).
From the paper
a decrease in contrast during natural stimulation caused only a small decrease in sparseness (4%), but larger decreases in sparseness were evident for a decrease in contrast during white noise stimulation (16%)
Criterion
Sparseness as in the Methods, of the trial-averaged 8 ms firing rate over the 120 repeats of each 12 s segment (P7). Reproduced when both decreases are within tolerance under reading P1 (a) or (b), and the WN decrease exceeds the NS decrease; partially reproduced when the ordering holds and the sizes do not. Paired t tests are reported; the significance marks of Figure 6B could not be read, so none is required.
A decrease in correlations decreases sparseness by 14%.
From the paper
and for a decrease in correlations (14%)
Criterion
As fig6b-sparseness-contrast, for LC NS against LC WN; reproduced when the decrease is within tolerance under P1 (a) or (b). The paired t test is reported.
Filtering by the RF raises the effective contrast of the natural movies relative to white noise, so that low-contrast natural movies and high-contrast white noise have similar effective contrasts despite different RMS contrasts.
From the paper
spatiotemporal integration in the RF results in an increase in the effective contrasts of the NS stimuli relative to those of the WN stimuli, indicating that the NS stimuli contain more of the features to which the RF is sensitive
Criterion
Generic RFs per stimulus as the mean of the cells' RFs with OFF-center RFs sign reversed (Results, Contrast- and Correlation-Induced Changes, paragraph 3; Figure 7A legend), normalized to unit variance (Figure 7B legend); effective contrast is the SD of the stimulus filtered by the generic RF, RMS contrast the SD of the stimulus (Figure 7C text). Open are the cells averaged, readings (a) the 31 with all four stimuli, (b) all cells with each stimulus, and the stimulus filtered, readings (a) the long segments, (b) the 12 s repeated segments. Reproduced when, under one reading, the ratio of effective to RMS contrast is higher for each NS stimulus than for each WN stimulus, and the LC NS effective contrast is closer to the HC WN value than to that of any other stimulus.
Normalized to high-contrast natural movies, the effective contrasts of the four stimuli correspond closely to the observed reliability of LGN responses.
From the paper
a comparison of the effective contrasts of the four stimuli (line) with the experimentally observed reliability in the LGN responses (circles) reveals a strong correspondence
Criterion
Effective contrast as in fig7c-effective-contrast; reliability the mean over the 31 cells per stimulus; both divided by their HC NS value, the across-cell SD of reliability divided likewise (Figure 7D legend). Reproduced when the four stimuli rank the same on both and each normalized effective contrast lies within one normalized SD of the normalized mean reliability; partially reproduced when the ranks agree only.
The natural movies filtered by the generic RFs have heavy-tailed distributions (kurtosis 4.06) while filtered white noise is Gaussian (kurtosis 3.01), and shuffling the movie frames before filtering removes the excess kurtosis.
From the paper
The distributions of the filtered NS stimuli (red and blue) have relatively heavy tails ... indicated by a high kurtosis (k = 4.06), while those of the filtered WN stimuli (black and gray) are Gaussian (k = 3.01). The high kurtosis in the distributions of the filtered NS stimuli disappears when the frames of the stimuli are shuffled
Criterion
Kurtosis (non-excess, Gaussian = 3) of each stimulus filtered by its generic RF, as in fig7c-effective-contrast. Which NS stimulus gives 4.06 is open; readings (a) HC NS, (b) LC NS, (c) both. Reproduced when, under one reading, the NS and WN values are within tolerance and the frame-shuffled HC NS stimulus filtered by the HC NS generic RF has a kurtosis within 0.30 of 3 (the WN tolerance).
The generic LN model with the high-contrast natural movie RF and NL gives a response sparseness of 0.86 to the movie and 0.83 when the movie frames are shuffled.
From the paper
the sparseness of the response of the generic LN model (with high-contrast natural scene RF and NL) to the original high-contrast NS stimulus is 0.86, and shuffling the frames of the stimulus decreases this value to 0.83
Criterion
The generic NL is a perfect half-wave rectifier with the sample-mean gain and offset (Results, paragraph 3); open is whether the offset used is (a) the mean normalized offset times the SD of the filtered stimulus or (b) the mean absolute offset. Sparseness of the model rate in 8 ms bins. Reproduced when, under one reading, both values are within tolerance and the shuffled value is the lower.
The sparseness of the noiseless generic LN model increases as contrast and correlations decrease, the opposite of the experimental responses, matching the experiment only for high-contrast natural movies.
From the paper
the sparseness of the model responses (line) increases as contrast and correlations are decreased. However, this is the opposite of what is observed in the experimental responses (circles)
Criterion
Model as in fig8-model-sparseness-shuffle, one generic model per stimulus. Reproduced when model sparseness is lowest for HC NS and highest for LC WN, the mean experimental sparseness is higher for HC NS than for LC WN, and the model HC NS value lies within one across-cell SD of the experimental HC NS mean (Figure 8B legend).
Adding Gaussian white noise to the filtered stimulus before the nonlinearity lowers model sparseness most for low-contrast white noise, and at one noise level the model and experimental sparseness agree closely for all four stimuli.
From the paper
as the noise level is increased, the sparseness of the model responses is decreased, with the strongest decreases for the low-contrast WN responses ... there is a certain noise level (Figure 8D, green bar) at which the sparseness of the model and experimental responses are in close agreement
Criterion
The noise level is not given; its SD is scanned from zero upward. Sparseness of the trial-averaged model response is open; readings (a) the model rate with noise, one realization, (b) the mean over 120 noisy trials as in the experiment. Reproduced when, under one reading, the decrease in sparseness with noise is largest for LC WN, and at some level the model value for each stimulus lies within one across-cell SD of the experimental mean (Figure 8E legend).
Low-contrast natural movies and high-contrast white noise, which have similar effective contrasts, evoke responses of similar reliability and sparseness, those to white noise slightly higher, so the decreases seen with a decrease in correlations disappear.
From the paper
when comparing responses to lowcontrast NS and high-contrast WN stimuli, the decreases in reliability and sparseness corresponding to the decrease in correlations are no longer evident ... In fact, the reliability and sparseness of the high-contrast WN responses are slightly higher than those of the low-contrast NS responses
Criterion
A claim of absence, judged with the Figure 6 test, paired t tests over the 31 cells of LC NS against HC WN, reliability and sparseness as in fig6a and fig6b. Reproduced when neither shows HC WN significantly lower at p < 0.05 (P3) and both HC WN means are above the LC NS means; the differences are reported.
The differences in spatial width, surround strength, gain and normalized offset between low-contrast natural movies and low-contrast white noise remain significant when low-contrast natural movies are compared with high-contrast white noise.
From the paper
nearly all of the observed differences between low-contrast natural scene and white noise RFs and NLs (spatial width, surround strength, gain, and normalized offset) are still significant when RFs and NLs are compared across low-contrast NS and high-contrast WN
Criterion
Paired t tests over the 31 cells of LC NS against HC WN for the four properties. The level is not stated; readings (a) p < 0.05, (b) p < 0.001 as in the Figures 3 and 4 legends. Each difference must be in the direction of the LC NS against LC WN change (WN narrower, weaker surround, higher gain, higher normalized offset). "Nearly all" is read as at least three of the four. Reproduced when, under one reading, at least three are significant in that direction.
Changes in contrast and correlations significantly change the latency (time to peak) of the RF center's temporal profile but not its biphasic ratio.
From the paper
Changes in contrast and correlations also had significant effects on the latency (time to peak) of the temporal profile of the RF center, but not on the biphasic ratio
Criterion
Latency is the lag of the peak of the center temporal profile; biphasic ratio the absolute peak of the primary phase over the peak of the secondary phase (Methods). Paired t tests for the three comparisons (HC against LC NS, HC against LC WN, LC NS against LC WN). The level for latency is open, readings p < 0.05 and p < 0.001; the absence for the biphasic ratio is judged at p < 0.05 (P3). Reproduced when, under one reading, latency changes in all three comparisons and the biphasic ratio in none; partially reproduced when latency changes in at least two and the biphasic ratio in none.
Of the RF and NL parameters, only the offset q differs significantly across animals within a stimulus condition.
From the paper
The only RF or NL parameter value that was significantly different across animals for a given stimulus condition was q
Criterion
The test is not named. Readings (a) a one-way ANOVA of each parameter on animal, per stimulus condition, (b) a Kruskal-Wallis test. Parameters are spatial width, surround/center ratio, temporal width, gain, offset and normalized offset, unadjusted. The level is open, readings p < 0.05 and p < 0.001. Reproduced when, under one reading, q differs across animals in at least one condition and no other parameter does in any. Needs the animal of each cell.
The spatial RF center is wider for Y than X cells during high-contrast (0.75 against 0.63 deg) and low-contrast (0.73 against 0.63 deg) natural movies.
From the paper
The width of the spatial RF was significantly larger for Y cells than for X cells during both high-contrast (X, 0.63 ± 0.16 deg.; Y, 0.75 ± 0.18 deg.) and low-contrast (X, 0.63 ± 0.14 deg ... natural stimulation (t tests, p < 0.01)
Criterion
Tolerances are the SDs given. The counts of X and Y cells are from the 68-cell sample (19 + 11 X, 19 + 8 Y). Unpaired t tests of X against Y per contrast; reproduced when all four means are within tolerance and both tests give p < 0.01 with Y wider.
The relative surround strength is larger for Y than X cells during high-contrast natural movies (0.16 against 0.13).
From the paper
the relative strength of the surround was significantly larger for Y cells than for X cells during high-contrast natural stimulation (X, 0.13 ± 0.04, Y, 0.16 ± 0.06; t test, p < 0.05)
Criterion
Tolerances are the SDs given. Unpaired t test of X against Y, surround/center ratio as in fig3c-surround-contrast; reproduced when both means are within tolerance and p < 0.05 with Y larger.
During low-contrast white noise the temporal profile of the RF center is wider for OFF than ON cells (29 against 25 ms).
From the paper
the temporal profile of the RF center was significantly larger for OFF cells than for ON cells during low-contrast white noise stimulation (ON, 25 ± 0.4 ms; OFF, 29 ± 0.4 ms; t test, p < 0.01)
Criterion
The paper's spread (0.4 ms) is smaller than the 8 ms lag grid and is probably a standard error, so 10% of each value is used as tolerance. Unpaired t test of ON against OFF over the 31 cells with white noise; reproduced when both means are within tolerance and p < 0.01 with OFF wider.
LN model predictions are slightly more accurate for X than Y cells at high (0.73 against 0.69) and low (0.78 against 0.75) contrast, but the differences are not significant.
From the paper
the correlation coefficients between LN model predictions and experimental responses to repeated identical segments of novel NS stimuli (for firing rate in 8 ms bins) were higher for X cells than for Y cells at both HC (X, 0.73; Y, 0.69) and LC (X, 0.78; Y, 0.75), but these differences were not significant (t tests, p > 0.1)
Criterion
Prediction correlations as in ln-prediction-accuracy, over the classified cells of the 26. A claim of absence for the difference; unpaired t tests of X against Y per contrast. Reproduced when neither gives p < 0.05 (P3) and the four means are within tolerance under one reading of ln-prediction-accuracy; the p-values are reported, and whether they exceed 0.1.
RFs estimated by the paper's least-squares method from simulated LN responses to the movies do not differ significantly from those estimated from simulated responses to Gaussian white noise, so the movies' spherical asymmetry does not bias the RF estimates much.
From the paper
We estimated the RF from simulated responses to both Gaussian white noise stimuli and the movie stimuli used in this study and found that the estimates were not significantly different
Criterion
A simulation that uses the stimuli only. The known RF, the NL, the simulation length and the test are not given; readings for the RF (a) the generic HC NS RF, (b) a cell's estimated RF. Reproduced when the RLS estimates from movie-driven and white-noise-driven simulated responses agree within the spread of the nine segment estimates at every RF point under one reading. This claim needs no recorded spikes.
Pipeline
- Paper match
- done
- Paper
- done (stored)
- Claims
- done
- Claims check
- done (ready)
- Attempt
- todo
- Questions
- none
- Verified
- none