Papers / Laquitaine et al. 2024

Laquitaine et al. 2024 · Preprint

Spike sorting biases and information loss in a detailed cortical model

Steeve Laquitaine, Milo Imbeni, Joseph Tharayil, James B. Isbister, Michael Reimann

Outcomes of 39 claims

  • 7 reproduced
  • 6 partially reproduced
  • 11 not reproduced
  • 15 blocked

Summary: The amplitude and noise of the simulated traces rise with depth as in vivo, and Kilosort4 yields far fewer single units than the model predicts, mostly degraded ones. The in vivo amplitude-to-noise range, power-law spectra, six WaveMap profiles (8 clusters in the simulation), log-normal firing rates and the layer 5 selection bias did not reproduce. The accuracy, curation and predictor claims could not be tested, as sortings of the synthetic and 10-minute evoked recordings are missing or analyses were too large. The five manifold claims could not be tested, as the dandiset has no stimulus table.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Laquitaine et al. (2024) from dandiset 001250 28 Open in Colab

Reproduced7

  • Reproduced

    After gain and noise fitting, the maximal amplitude of the spontaneous Neuropixels simulation (361 uV) matches that of the Marques-Smith recording (362 uV), and the evoked simulation reaches 387 uV.

    Over the whole first 600 s, under reading (a), after preprocessing, the maxima over cortical sites are 331.1…

    Methods, Fitting amplitude and background noise, paragraph 1uses data from outside the datasetfitted-trace-maximal-amplitude
    From the paper

    The spontaneous regime’s maximal amplitude (361 µV) closely matched Marques-Smith’s (362 µV), while the evoked regime produced a slightly higher value (387 µV)

    Result

    Over the whole first 600 s, under reading (a), after preprocessing, the maxima over cortical sites are 331.1 uV for NS, 363.5 for M and 387.0 for the 1-hour evoked recording (380.0 for the 10-minute one), all within 10% of 361, 362 and 387. Under reading (b), the raw traces, NS 372.7 and M 374.0 are within, and the evoked value is within for the 10-minute recording (421.1) but not for the 1-hour one (435.6). On the 60 s blocks of the first version the outcome was the same (reading b, 360.4, 345.0 and 424.7). The maxima still grow with duration (E40 raw 385.4 after the first 60 s, 421.1 after 600 s).

    Deviations from the paper’s method
    • The maxima are streamed over the whole first 600 s in 2.5 s blocks, each filtered with 50 ms margins (verifier round 1); the 60 s blocks are shown as a variant.
  • Reproduced

    In both in vivo datasets the median peak amplitude of the traces increased with cortical depth, and the biophysical models reproduced this trend, although their medians differed from in vivo.

    Kruskal-Wallis across layers gives p = 1.2e-25 (NS), 1.2e-23 (E), 2.2e-07 (DS), 2.0e-32 (M) and 3.6e-25 (H)…

    Results, Validation of recording traces, paragraph 2; Figure 2m, ouses data from outside the datasetfig2m-peak-amplitude-increases-with-depth
    From the paper

    In both Marques-Smith and Horvath’s data, median peak amplitude increased with cortical depth ... While the models’ median peak amplitudes differed from in vivo (most p < 0.01, Mann-Whitney U test), all captured the in vivo trend

    Reported statistics
    • peak amplitude across layers, in vivo and in each model: Kruskal-Wallis, p < 0.001
    • model against in vivo median peak amplitude, per layer: Mann-Whitney U test, p < 0.01
    Result

    Kruskal-Wallis across layers gives p = 1.2e-25 (NS), 1.2e-23 (E), 2.2e-07 (DS), 2.0e-32 (M) and 3.6e-25 (H), and the layer medians rise from layer 1 to layer 6 with one inversion in each (layer 6 below layer 5, or for DS layer 4 below layer 2/3). Models differ from in vivo at p < 0.01 in 12 of 15 layer comparisons with H in counts, as the statement's "most p < 0.01" says (1 of 5 for DS against H scaled to 0.195 uV per count).

    Deviations from the paper’s method
    • Traces are six 10 s blocks of the first 10 minutes (60 s per recording), not 10 minutes.
    • E is the 1-hour evoked recording (sub-002-fitted), as in the code; the 10-minute recording is shown and gives the same.
    • The Horvath files' scale is inconsistent (finding); H in counts is used for DS against H, as the fitted dense model's noise matches H in counts (median 28.3 against 28.7) and not at 0.195 uV per count (5.6). The comparison with H is reported and does not decide the outcome.
  • Reproduced

    Background noise increased with cortical depth in vivo, and the biophysical models reproduced this trend.

    Noise (mean absolute deviation, minimum over 1 s segments) differs across layers in NS (p = 1.4e-35), E…

    Results, Validation of recording traces, paragraph 2; Figure 2n, puses data from outside the datasetfig2np-noise-increases-with-depth
    From the paper

    In vivo background noise also increased with cortical depth ( p < 0.001, Kruskall Wallis, Fig. 2n, p ), a trend reproduced by the biophysical models

    Reported statistics
    • Kruskal-Wallis, p < 0.001
    Result

    Noise (mean absolute deviation, minimum over 1 s segments) differs across layers in NS (p = 1.4e-35), E (2.9e-34), DS (p below 1e-300), M (1.9e-14) and H (2.0e-31), with medians rising from layer 1 to layer 5 and one inversion at layer 6 in every experiment. The median absolute deviation gives the same pattern.

    Deviations from the paper’s method
    • Traces are 60 s per recording (six 10 s blocks of the first 10 minutes), not 10 minutes, so the minimum over 1 s segments is over 60 segments, not 600.
  • Reproduced

    The Horvath traces are dominated by slow (0.5 to 1.5 Hz) and delta (1 to 4 Hz) waves of slow-wave sleep, which the Marques-Smith traces and the biophysical models lack.

    The share of 0.5 to 300 Hz power that lies in 0.5 to 4 Hz is 0.702 in H against 0.092 (M), 0.038 (NS), 0.066…

    Results, Validation of recording traces, paragraph 4; Supplementary figure "Validation of raw simulated traces"uses data from outside the datasetsupp2-no-slow-oscillations
    From the paper

    In Horvath’s data but not in Marques-Smith’s, the traces were dominated by high-amplitude slow (0.5 - 1.5Hz) and δ waves (1 - 4Hz) characteristic of slow-wave sleep ... The biophysical models did not replicate these oscillations

    Result

    The share of 0.5 to 300 Hz power that lies in 0.5 to 4 Hz is 0.702 in H against 0.092 (M), 0.038 (NS), 0.066 (E) and 0.038 (DS), so H's share is 7.6 to 18.7 times the others'.

    Deviations from the paper’s method
    • Spectra at 1 Hz resolution from six 10 s raw blocks, not 10 minutes; the 0.5 Hz bin is not resolved, so the band is the 1 to 4 Hz bins.
  • Reproduced

    The peak-to-peak amplitude of a model cell's spikes drops by more than half within 75 um of the soma, and the trace is strongly distorted by noise beyond 200 um.

    Every electrode 75 um or more from the soma has an isolated spike-triggered peak-to-peak amplitude below half…

    Results, Validation of single unit spike waveforms, paragraph 1; Figure 3d, efig3e-amplitude-decay-with-distance
    From the paper

    The peak-to-peak amplitude of the spikes rapidly decayed between nearby electrodes, dropping by more than half within 75 µm ( Fig. 3e ), therefore making the summed extracellular potentials difficult to isolate at 75 µm from the somata. The extracellular traces was strongly distorted by noise beyond 200 µm

    Result

    Every electrode 75 um or more from the soma has an isolated spike-triggered peak-to-peak amplitude below half that of the nearest electrode. The largest is 0.408 of it with the electrode of largest amplitude as the soma, and 0.339 with the code's soma position. Beyond 200 um the summed trace's spike-triggered peak-to-peak is below 5 MAD at all 122 electrodes (the reported part, a threshold of the claims file). The Reyes grid is sparse. With the electrode of largest amplitude as the soma, one electrode lies within 25 um, none in 25 to 50 um, and one in each of 50 to 75 and 75 to 100 um; with the code's soma position the nearest is at 25.5 um, and one lies in each 25 um band from 25 to 100 um.

    Deviations from the paper’s method
    • The files hold no soma position; distances are from the electrode of largest amplitude, with the code's soma position as a variant (an outside input). Both give the same outcome.
  • Reproduced

    In vivo, multi-units were twice as frequent with the dense probe as with Neuropixels, which the model did not reproduce; despite its higher-resolution sampling the dense probe did not give a higher single-unit yield than Neuropixels.

    M has 104 and H 265 multi-units (exact), H's multi-unit share is higher (0.74 against 0.52), and the code's…

    Results, Model predicts low yield, quality and biases, paragraph 4; Figure 5auses data from outside the datasetfig5a-dense-probe-more-multi-units
    From the paper

    These were mostly ‘multi-units’, which were twice more frequent for the dense probe in vivo (M:104, H:265, χ 2 (1, N = 558) = 6.6, p = 0.01). The model did not reproduce this effect (NS:182, DS:206, χ 2 (1, N = 1066) = 0.004, p = 0.9)

    Reported statistics
    • Marques-Smith against Horvath: chi-square, chi2(1, N = 558) = 6.6, p = 0.01
    • NS against DS: chi-square, chi2(1, N = 1066) = 0.004, p = 0.9
    Result

    M has 104 and H 265 multi-units (exact), H's multi-unit share is higher (0.74 against 0.52), and the code's goodness-of-fit test gives chi2 = 6.56, p = 0.0105 (paper 6.6, p = 0.01). NS against DS does not differ (p = 0.49, chi2 = 0.47 against the paper's 0.004; 0.29 with DS as deposited).

    Deviations from the paper’s method
    • DS sums depths 2 and 3 (481 units against the paper's 562), as the deposited depth 1 sortings are copies of depth 2's.
  • Reproduced

    Most single units isolated by Kilosort4 are less than 80% accurate, contain spikes of several true neurons (merged) and miss at least 20% of their matched neuron's spikes; Kilosort4 produces no false positives.

    Among cortical Kilosort4 single units, 54.3% (NS, 184 units) and 74.2% (E, 407) have a best agreement score…

    Results, Model predicts low yield, quality and biases, paragraph 7; Figure 5c, drests on an assumptionfig5cd-most-units-degraded
    From the paper

    The majority of the isolated ‘single-units’ were less than 80% accurate and degraded across layers ( Fig. 5d , white area) and spike sorters ( Supplementary Fig. 5b ). They contained spikes from multiple true units (’merged unit’) and missed at least 20% of the matched true units spikes ( Fig. 5c , green). Kilosort4 did not produce false positives

    Result

    Among cortical Kilosort4 single units, 54.3% (NS, 184 units) and 74.2% (E, 407) have a best agreement score below 0.8, all are tagged merged, and none is a false positive. The merged part is met almost by chance coincidence over many neurons - the median Kilosort4 single unit scores above chance with 308 (NS) and 597 (E) neurons - so it says little about the sorting. The other sorters give 57.8% to 96.4% below 0.8 and 96.6% to 100% merged, with up to 37 false positives (Kilosort on E).

    Deviations from the paper’s method
    • E is the first 10 minutes of the 1-hour recording.
    • Agreement scores use SpikeInterface 0.105 (the paper used 0.100.5). After verification round 1 the quality tags are computed over every sorted unit of the sorting, and "partial" looks only at the unit's above-chance neurons, as the claims file defines it; the Kilosort4 numbers are unchanged. The Kilosort2 sorting of E is scored over its 240 s.
    • Assumed after verification round 2. E, the first 10 minutes of the 1-hour 20 kHz recording, is taken as the paper's evoked recording of Figures 4 and 5. The criterion leaves the evoked recording open and asks for both; the 10-minute 40 kHz recording (E40) has no deposited sorting, so it cannot be tested. The basis is that the deposited E Kilosort4 sorting matches E's ground truth (250 units with an agreement of 0.5 or more) and not E40's (none), and that it reproduces the code's printed median of 0.655 spikes/s (fig4-median-firing-rates). Asked of a reader (questions/001250.yaml).

Partially reproduced6

  • Partially reproduced

    In the biophysical models the power in the spike frequency band and the power-law scaling slope in the spiking band increased with cortical depth, as in vivo; the dense probe model had weaker power and slope than in vivo but within the in vivo range.

    AP power in 0.3 to 2 kHz rises with depth in NS, E and DS under both readings, median PSD and summed power…

    Results, Validation of recording traces, paragraph 3; Figure 2s-vuses data from outside the datasetfig2s-v-ap-power-and-scaling-increase-with-depth
    From the paper

    The biophysical models’ median power in the frequency band of a spike waveform and the scaling slope in the spiking band also increased with cortical depth as in vivo (2s-v, all p < 0.001, Kruskall Wallis) ... Nonetheless the dense probe’s AP power and frequency scaling remained within in vivo range

    Reported statistics
    • Kruskal-Wallis, p < 0.001
    Result

    AP power in 0.3 to 2 kHz rises with depth in NS, E and DS under both readings, median PSD and summed power (Kruskal-Wallis p from 1.2e-41 to 3.0e-32, at most one inversion), so the AP power part holds without the methods_underspecified case. The slope alpha differs across layers in every model (p below 1e-8), but its layer medians do not rise in every model. Read as steepness (|alpha|) it holds for E and DS and fails for NS (two inversions); read as the signed slope it fails for all three. With H in counts, DS has weaker AP power (median summed power 257 against 1,723 uV2) and a shallower slope (-0.10 against -1.27) than H, but only 9.5% (summed power) and 3.3% (alpha) of DS sites lie within H's range; with H at 0.195 uV per count, 88.5% of DS sites lie within H's summed power range. The 0.3 to 1 kHz variant gives the same for the models.

    Deviations from the paper’s method
    • Traces are 60 s per recording, not 10 minutes.
    • The claims file does not say whether "the scaling slope increased" refers to the signed slope or its magnitude; both are shown, and the outcome is partial under both.
  • Partially reproduced

    The median firing rate of sorted single units over layers 5 and 6 is 2.8 spikes/s in Marques-Smith's data, 1.2 in the spontaneous and 0.7 in the evoked simulations, and 5 in Buccino's synthetic simulation.

    Under reading (a), the median of the pooled layer 5 and 6 rates, M is 2.85, NS 1.16 and E 0.66 spikes/s, all…

    Results, Validation of firing rates, paragraph 2; Figure 4brests on an assumptionuses data from outside the datasetfig4-median-firing-rates
    From the paper

    The overall median firing rate averaged over layer 5 and 6 differed but only by a small margin (Marques-Smith: 2.8 ± 1% (95% CI) spikes/secs, spontaneous biophysical simulation: 1.2 ± 0.2%, evoked simulation: 0.7 ± 0.1% and Buccino’s full synthetic simulation: 5 ± 0.4% (95% CI))

    Result

    Under reading (a), the median of the pooled layer 5 and 6 rates, M is 2.85, NS 1.16 and E 0.66 spikes/s, all within the paper's intervals, and the 1.96 SD / sqrt(n) of the code is 1.14, 0.21 and 0.08, as the code printed. Under reading (b) E is 0.81, outside. The fourth value, Buccino's synthetic simulation, cannot be computed, as the dandiset holds no sorting of it.

    Deviations from the paper’s method
    • E is the first 10 minutes of the 1-hour recording.
    • No value for S (no sorting in the dandiset).
    • Assumed after verification round 2. E, the first 10 minutes of the 1-hour 20 kHz recording, is taken as the paper's evoked recording of Figures 4 and 5. The criterion leaves the evoked recording open and asks for both; the 10-minute 40 kHz recording (E40) has no deposited sorting, so it cannot be tested. The basis is that the deposited E Kilosort4 sorting matches E's ground truth (250 units with an agreement of 0.5 or more) and not E40's (none), and that it reproduces the code's printed median of 0.655 spikes/s (fig4-median-firing-rates). Asked of a reader (questions/001250.yaml).
    • Assumed after verification round 2. Partially reproduced is used for "every part that can be tested holds and the rest cannot be tested", which the criterion does not provide for (it names no partial outcome). Without this convention the claim would be blocked (data_missing, S) for its untested parts.
  • Partially reproduced

    Compared with in vivo, the biophysical simulations have lower median firing rates and narrower firing rate distributions across layers, while the synthetic model has a lower variance in layer 5 but a higher median.

    In layers 5 and 6 (the only layers with three or more M single units) NS and E have lower medians than M…

    Results, Validation of firing rates, paragraph 2; Figure 4b, crests on an assumptionuses data from outside the datasetfig4bc-lower-median-narrower-distribution
    From the paper

    Specifically, the biophysical simulations had lower median firing rates ( Fig. 4b , p < 0.001, Mann-Whitney) and distributions were narrower ( c, p < 0.001) than in vivo across layers. For reference, the synthetic model distribution also had a lower variance in layer 5 (all p < 0.01) but it displayed higher median firing rate ( p < 0.01)

    Reported statistics
    • median log10 firing rate, biophysical simulations against Marques-Smith: Mann-Whitney U test, p < 0.001
    • variance of log10 firing rate, biophysical simulations against Marques-Smith: Mann-Whitney U test on 100 bootstrapped variances, p < 0.001
    • synthetic against Marques-Smith, layer 5, variance and median: Mann-Whitney U test, p < 0.01
    Result

    In layers 5 and 6 (the only layers with three or more M single units) NS and E have lower medians than M (Mann-Whitney p from 4.3e-08 to 2.2e-04) and lower bootstrapped variances (p below 1e-20), 4 of 4 comparisons each, so the biophysical part holds. The synthetic model's part (layer 5 variance and median against M) cannot be tested, as S has no sorting.

    Deviations from the paper’s method
    • E is the first 10 minutes of the 1-hour recording.
    • Assumed after verification round 2. E, the first 10 minutes of the 1-hour 20 kHz recording, is taken as the paper's evoked recording of Figures 4 and 5. The criterion leaves the evoked recording open and asks for both; the 10-minute 40 kHz recording (E40) has no deposited sorting, so it cannot be tested. The basis is that the deposited E Kilosort4 sorting matches E's ground truth (250 units with an agreement of 0.5 or more) and not E40's (none), and that it reproduces the code's printed median of 0.655 spikes/s (fig4-median-firing-rates). Asked of a reader (questions/001250.yaml).
    • Assumed after verification round 2. Partially reproduced is used for "every part that can be tested holds and the rest cannot be tested", which the criterion does not provide for (it defines partial as the medians or the variances part holding alone, while here both hold and the S part cannot be tested). Without this convention the claim would be blocked (data_missing, S) for its untested parts.
  • Partially reproduced

    For the spontaneous Neuropixels simulation sorted by Kilosort4, on average 41% of sorted units are single units, and the proportion of single units differs between experiments.

    The proportion of single units differs between experiments under reading (c), chi2(4, N = 5,079) = 488.6, p =…

    Results, Model predicts low yield, quality and biases, paragraph 2; Figure 5arests on an assumptionuses data from outside the datasetfig5a-single-unit-fraction-differs
    From the paper

    We found that for spontaneous activity recorded with Neuropixels and sorted by Kilosort4, on average 41% of sorted units were ‘single-units’. This proportion differed between experiments

    Reported statistics
    • chi-square, chi2(4, N = 5,241) = 43.9, p < 0.001
    Result

    The proportion of single units differs between experiments under reading (c), chi2(4, N = 5,079) = 488.6, p = 1.9e-104 (M, H, NS, E, DS), and on the experiments available for readings (a) and (b) (M, NS, E; p = 2e-05 and 8.7e-76). The 41% is not found under reading (i), the only one that can be computed; NS's fraction is 0.354 (184 of 520), outside 0.369 to 0.451. Readings (ii) and (iii) need NS-2X, which is not in the dandiset. The paper's own NS counts (182 of 504) also give 36%. For reference only, with NS-2X taken from the paper's counts (193 of 508), reading (ii) gives 0.367 (outside) and reading (iii), which the claims file says the paper's counts favour, 0.405 (within); these use the paper's numbers and do not decide the outcome.

    Deviations from the paper’s method
    • NS-2X and S have no sorting, so readings (a) and (b) are run on M, NS and E only.
    • NS has 520 cortical Kilosort4 units against the paper's 504.
    • Assumed after verification round 2. The test part holds; the fraction fails under reading (i), the only one the dandiset allows, and readings (ii) and (iii) need NS-2X. Partially reproduced is used for "one part holds and the other cannot be fully tested", which the criterion does not provide for (it names no partial outcome). Without this convention the claim would be blocked (data_missing, NS-2X) for the fraction.
  • Partially reproduced

    The simulations give at least twice as many single units as in vivo (182 and 193 against 96 for Neuropixels, 206 against 93 for the dense probe), yet the fractions of single units are similar.

    Single-unit counts are NS 184 (182), M 96 (96) and H 93 (93), within tolerance.

    Results, Model predicts low yield, quality and biases, paragraph 2; Figure 5arests on an assumptionuses data from outside the datasetfig5a-single-unit-counts
    From the paper

    At least twice more ‘single-units’ were detected from the simulations than in vivo , with the largest difference being 206 vs. 93 for the dense probe ( Fig. 5a , 182 and 193 vs. 96 for Neuropixels). Yet the fractions of ‘single-units’ were similar

    Reported statistics
    • Neuropixels, Marques-Smith against simulations: chi-square, chi2(2, N = 1,212) = 2.0, p = 0.37
    • dense probe, Horvath against simulation: chi-square, chi2(1, N = 920) = 1.8, p = 0.18
    Result

    Single-unit counts are NS 184 (182), M 96 (96) and H 93 (93), within tolerance. Neither test of the fractions can be run as the criterion has it. The NS-2X count (193) and the paper's three-way test with it cannot be computed, as NS-2X is not in the dandiset; M against NS, run two-way, gives p = 0.17 (with NS-2X taken from the paper's counts, 193 of 508, the three-way test gives p = 0.33, for reference only). The DS count is incomplete, as depth 1 has no sorting of its own; depths 2 and 3 give 199 single units of 481 (fraction 0.414, against the paper's 206 of 562, 0.367) and H against DS p = 0.061, while the deposit with DS2 counted twice gives 275, outside tolerance, and p = 0.024. So H against DS is undetermined. If depth 1 adds the 81 units that separate 481 from the paper's 562, p is 0.05 or more when 37 or fewer of them are single and below 0.05 when 38 or more are; the paper's own total (206 single units, 7 more) gives chi2 = 1.82, p = 0.177, its printed 1.8, which confirms the form of the test. That the fractions do not differ is not established. The measured values are given for NS, M, DS (depths 2 and 3) and H, in that order, NS-2X having none.

    Deviations from the paper’s method
    • DS sums depths 2 and 3, as the deposited depth 1 sortings are copies of depth 2's.
    • The contingency chi-square variant gives p = 0.0025 (M, NS) and 5.2e-06 (H, DS).
    • Assumed after verification round 2. Partially reproduced is used for "the counts that can be computed hold and the rest cannot be tested", which the criterion does not provide for (it names no partial outcome). Without this convention the claim would be blocked (data_missing, NS-2X and the depth 1 sortings) for its untested parts.
  • Partially reproduced

    Raw single-unit yields per site are an order of magnitude lower than the theoretical yields (active neurons within 50 um per site, NS 6.9, NE 8.4, S 0.65, DS 5.3) and do not differ significantly between probes or sorters.

    The theoretical yields are 6.88 (NS), 8.44 (E; 8.27 for the 10-minute recording) and 0.651 (S), within…

    Results, Model predicts low yield, quality and biases, paragraph 6; Figure 5b legendrests on an assumptionuses data from outside the datasetfig5b-yield-far-below-theory
    From the paper

    For the biophysical models, the raw single-unit yields were an order of magnitude lower than the theoretical yields and were not significantly different between probes or spike sorters (5b)

    Result

    The theoretical yields are 6.88 (NS), 8.44 (E; 8.27 for the 10-minute recording) and 0.651 (S), within tolerance. DS's cannot be computed, because the dense probe ground truth tables hold spike times only, with no soma layer or position (56 of DS1's 287 neurons can be found by name in the Neuropixels tables). Kilosort4's yield per site is 8.0 times below the theoretical one for NS and 4.8 times for E, an order of magnitude under reading (b), 3.16 or more, and not under reading (a), 10 or more. Across sorters the ratio ranges from 0.8 (Kilosort) to 9.2 (herdingspikes on E). No test of the differences between probes or sorters is run, as the criterion says. Both parts hold for what can be computed; only DS's theoretical yield stops a full reproduction.

    Deviations from the paper’s method
    • E's theoretical yield uses the first 10 minutes of the 1-hour recording; the 10-minute recording is shown.
    • Assumed after verification round 2. Partially reproduced is used for "every part that can be tested holds and the rest cannot be tested", which the criterion does not provide for (it defines partial as one of its two parts holding, while here both hold for what can be computed). Without this convention the claim would be blocked (metadata_insufficient, DS layers) for its untested parts.

Not reproduced11

  • Not reproduced

    The simulations hold spikes from 1,388 model neurons within 50 um of the Neuropixels probe in the spontaneous regime, 1,836 in the 1-hour evoked regime at 20 kHz and 1,552 in the 10-minute evoked regime at 40 kHz, and every one of them fired at least once in the first 10 minutes.

    The ground truth tables hold exactly 1,388 (NS), 1,836 (1-hour evoked) and 1,552 (10-minute evoked) units, and…

    Methods, Datasets and simulations, Biophysical model, paragraph 1verifier disagreed at firstground-truth-neuron-counts
    From the paper

    We detected spikes from 1,388 model neurons during the spontaneous activity condition, 1,836 model neurons during the 1-hour evoked condition sampled at 20 kHz, and 1,552 neurons during the 10 minute evoked condition sampled at 40 kHz, within 50 µm of the Neuropixels probe ... All model neurons fired at least once in the first 10 minutes

    Result

    The ground truth tables hold exactly 1,388 (NS), 1,836 (1-hour evoked) and 1,552 (10-minute evoked) units, and every soma is within 50 um of an electrode (largest distance 49.96 um). The statement that every neuron fired in the first 10 minutes does not hold. 78 NS neurons and 213 neurons of the 1-hour evoked recording have no spike in the first 600 s; all of them fire later in their files (none is silent over the whole file). All 1,552 neurons of the 10-minute recording fire. The criterion requires both parts and names no partial outcome, so the claim is not reproduced (changed from partially reproduced after verification round 1).

  • Not reproduced

    The amplitude-to-noise ratio distributions of the models span a wide dynamic range and lie within the in vivo range, with data between -10 and 10 times the noise level.

    Over the whole first 600 s every experiment has ANR values beyond -10 and +10, but no model lies within its in…

    Results, Validation of recording traces, paragraph 2; Figure 2quses data from outside the datasetfig2q-anr-within-vivo-range
    From the paper

    The distributions of ANRs observed in vivo and in the models showed a wide dynamic range, with alignment of data points between -10 and 10 times the noise level ( Fig. 2q ), particularly in layers 1, 5, and 6. Despite deviations from in vivo due to difference in peak amplitudes, simulated ANRs remained within the in vivo range

    Result

    Over the whole first 600 s every experiment has ANR values beyond -10 and +10, but no model lies within its in vivo range widened by 10%. NS (-149.2 to 54.5), E (-158.5 to 58.3) and E40 (-152.7 to 53.5) extend beyond M's widened range (-112.6 to 41.1) at both ends, and DS (-207.7 to 89.8) beyond H's (-177.6 to 68.9) at both ends. On the 60 s blocks, DS lay within H's range and NS and E did not, so the outcome does not depend on the duration. More than 99.7% of the samples of the 60 s blocks have |ANR| below 10 in every experiment.

    Deviations from the paper’s method
    • The ANR extremes use the minimum and maximum of the preprocessed traces over the whole first 600 s, divided by each site's median absolute deviation from the 60 s blocks (verifier round 1); the histograms use the 60 s blocks.
  • Not reproduced

    In simulated and real traces, power decreased with frequency in the spiking band (0.3 to 6 kHz) and followed a power law in all layers.

    The log-log slope of the median normalised spectrum in 0.3 to 6 kHz is negative in all 30 layer and experiment…

    Results, Validation of recording traces, paragraph 3; Figure 2ruses data from outside the datasetfig2r-power-law-spiking-band
    From the paper

    In both the simulated and real traces, power decreased with increasing frequency in the frequency band of spiking activity (0.3 - 6 KHz) and followed a power law in all layers

    Result

    The log-log slope of the median normalised spectrum in 0.3 to 6 kHz is negative in all 30 layer and experiment pairs, but R2 is 0.9 or more in only 7 (M layers 5 and 6, all five H layers). In the models R2 ranges from 0.05 (DS layer 1) to 0.89 (10-minute E, layer 5); NS ranges from 0.41 to 0.85. The R2 threshold is the claims file's reading of "followed a power law".

    Deviations from the paper’s method
    • Spectra are Welch averages over six 10 s blocks, not the first 10 minutes.
  • Not reproduced

    Spikes sorted with Kilosort3 from the spontaneous Neuropixels simulation qualitatively match the five temporal profiles reported in humans and cats.

    The criterion judges this claim with fig3fg-wavemap-six-profiles, which is not reproduced (8 WaveMap clusters…

    Results, Validation of single unit spike waveforms, paragraph 1; Figure 3a-cfig3c-five-temporal-profiles
    From the paper

    The simulated temporal waveforms qualitatively matched the five shapes reported in cats [ 46 ] and humans [ 9 ]

    Result

    The criterion judges this claim with fig3fg-wavemap-six-profiles, which is not reproduced (8 WaveMap clusters for NS, 6 for M). The qualitative comparison with the five shapes of cats and humans has no measure and was not run.

  • Not reproduced

    WaveMap clustering of multi-electrode spike waveforms identifies six distinct profiles in the simulation, as in the Marques-Smith data.

    With the six nearest sites and the Louvain resolution that maximises modularity, NS's 230 Kilosort3 single…

    Results, Validation of single unit spike waveforms, paragraph 2; Figure 3f, guses data from outside the datasetfig3fg-wavemap-six-profiles
    From the paper

    Consistent with the experimental data, the algorithm identified six distinct profiles from the simulations

    Result

    With the six nearest sites and the Louvain resolution that maximises modularity, NS's 230 Kilosort3 single units give 8 clusters (9 and 7 with two other UMAP seeds) and M's 107 give 6 (all three seeds), so M matches and the simulation does not. Variants give NS 11 and M 6 with three sites, 8 and 5 with the six largest sites anywhere, 7 and 5 with units of 20 spikes or more, 12 and 8 at resolution 1.5, E 8 and NS with E pooled 12. The claims file notes that the code's own saved outputs printed 7 to 10 clusters for NS and 7 for M.

    Deviations from the paper’s method
    • Templates are means over each unit's spikes inside the six 10 s blocks (median 43 spikes for NS, 54 for M), not over all spikes of 10 minutes.
    • The six sites are the site of largest template amplitude and the sites nearest to it (3-D positions for the models), ordered by amplitude ("the six nearest sites", Methods, WaveMap), each 6 ms segment resampled to 50 points (the WaveMap paper's length, a standard choice so that 30 and 40 kHz give vectors of one length) and the concatenated vector scaled to 0 to 1; the UMAP seed is a standard choice, shown with two others. The code's own WaveMap notebook uses other settings (n_neighbors 6, bandpass to 3 kHz, waveform curation) than the Methods; the claims file's criterion is followed.
    • Louvain is run on UMAP's neighbour graph (python-louvain), as WaveMap does; umap-learn and python-louvain are recent versions, not 0.5.3 and 0.16.
  • Not reproduced

    The firing rates of single units sorted by Kilosort4 from the spontaneous and evoked simulations are distributed log-normally across layers, as in Marques-Smith's data.

    Shapiro-Wilk on log10 rates of Kilosort4 single units does not reject normality in M (layer 5 p = 0.84, n =…

    Results, Validation of firing rates, paragraph 2; Figure 4arests on an assumptionquestion to the readeruses data from outside the datasetfig4a-lognormal-firing-rates
    From the paper

    Like Marques-Smith’s sorted unit firing rates, the firing rates from the spontaneous (red dots, Fig. 4a ) and evoked (orange dots) biophysical simulations were distributed log-normally across layers

    Result

    Shapiro-Wilk on log10 rates of Kilosort4 single units does not reject normality in M (layer 5 p = 0.84, n = 20; layer 6 p = 0.31, n = 74) but does in NS layer 6 (p = 0.014, n = 39) and E layer 5 (p = 0.00056, n = 300). NS layer 5 (p = 0.19) and E layer 6 (p = 0.93) pass, so each simulation fails in one deep layer, and neither the full nor the partial outcome holds.

    Deviations from the paper’s method
    • E is the first 10 minutes of the 1-hour recording; the 10-minute 40 kHz recording has no deposited sorting.
    • Assumed after verification round 2. E, the first 10 minutes of the 1-hour 20 kHz recording, is taken as the paper's evoked recording of Figures 4 and 5. The criterion leaves the evoked recording open and asks for both; the 10-minute 40 kHz recording (E40) has no deposited sorting, so it cannot be tested. The basis is that the deposited E Kilosort4 sorting matches E's ground truth (250 units with an agreement of 0.5 or more) and not E40's (none), and that it reproduces the code's printed median of 0.655 spikes/s (fig4-median-firing-rates). Asked of a reader (questions/001250.yaml).
  • Not reproduced

    Single-unit yields are low in superficial layers and high in layers 5 and 6; in vivo the yields in these layers are at least 20 times that of layer 4 and no unit is found in layers 1 and 2/3, a trend also seen in the simulated data.

    M has 20 (layer 5) and 74 (layer 6) Kilosort4 single units against 1 in layer 4, ratios of 20 and 74 (94…

    Results, Validation of firing rates, paragraph 1; Figure 4a (unit counts)verifier disagreed at firstuses data from outside the datasetfig4a-yield-deep-layers
    From the paper

    In vivo , the yields in these layers were at least 20 times that in layer 4, and no units were found in layers 1 and 2/3, a trend also reflected in the simulated data

    Result

    M has 20 (layer 5) and 74 (layer 6) Kilosort4 single units against 1 in layer 4, ratios of 20 and 74 (94 pooled), and NS and E have more single units in layers 5 and 6 than in each of layers 1, 2/3 and 4. M has one single unit in layer 2/3, where the criterion requires none, so that part fails by one unit. The criterion names no partial outcome, so the claim is not reproduced, narrowly (changed from partially reproduced after verification round 1).

  • Not reproduced

    With other sorters, Kilosort3 gives log-normal firing rate distributions that match in vivo, older sorters give bimodal distributions, and across regimes the simulated medians and variances tend to be lower than in vivo.

    The Kilosort3 part, a claim of absence on the paper's test, fails.

    Results, Validation of firing rates, paragraph 3; Supplementary figure "Validation of firing rate distributions"rests on an assumptionuses data from outside the datasetsupp4-other-sorters-firing-rates
    From the paper

    While newer sorters like Kilosort3 produced log-normal distributions ( Supplementary Fig. 4a ) that better matched in vivo data (b, p > 0.15), older sorters often generated bimodal distributions ... firing rate medians (b, p < 0.05) and variances ( c, p < 0.01) in simulations tended to be reduced

    Reported statistics
    • Kilosort3, simulated against in vivo: Mann-Whitney U test, p > 0.15
    • medians, simulations against in vivo: Mann-Whitney U test, p < 0.05
    • variances, simulations against in vivo: Mann-Whitney U test, p < 0.01
    Result

    The Kilosort3 part, a claim of absence on the paper's test, fails. 2 of 4 median comparisons have p <= 0.15 (E layer 5 p = 0.0016, E layer 6 p = 0.058) and 4 of 4 variance comparisons do. Over the 18 comparisons of Kilosort, 2, 2.5 and 3 against M, 12 have lower variances at p < 0.01 but only 5 have lower medians at p < 0.05, so the "tended to be reduced" part fails on the medians. Hartigan's dip test rejects unimodality for Kilosort, 2 and 2.5 in every experiment, M included (p < 0.0001), and not for Kilosort 3 or 4 (p from 0.29 to 0.996).

    Deviations from the paper’s method
    • E is the first 10 minutes of the 1-hour recording.
    • Assumed after verification round 2. E, the first 10 minutes of the 1-hour 20 kHz recording, is taken as the paper's evoked recording of Figures 4 and 5. The criterion leaves the evoked recording open and asks for both; the 10-minute 40 kHz recording (E40) has no deposited sorting, so it cannot be tested. The basis is that the deposited E Kilosort4 sorting matches E's ground truth (250 units with an agreement of 0.5 or more) and not E40's (none), and that it reproduces the code's printed median of 0.655 spikes/s (fig4-median-firing-rates). Asked of a reader (questions/001250.yaml).
    • The Kilosort2 sorting of E covers 240 s (its last spike), as the Methods say Kilosort2 sorted 4 minutes of the evoked recording, so its rates are counts over 240 s (verifier round 1). The counts of the outcome are unchanged by this.
  • Not reproduced

    The model predicts that in a stimulus-evoked regime the number of sorted units increases at least threefold and the single-unit yield doubles, while the ratio shifts toward multi-units.

    E has 6.77 times NS's cortical Kilosort4 units (3,520 against 520) and a lower single-unit fraction (0.116…

    Results, Model predicts low yield, quality and biases, paragraph 3; Figure 5averifier disagreed at firstrests on an assumptionquestion to the readerfig5a-evoked-more-units
    From the paper

    The model predicts that the number of sorted units should increase at least three times in a stimulus-evoked regime. Although the ratio should strongly shift to ‘multi-units’, a key prediction is that the single-unit yield should double

    Result

    E has 6.77 times NS's cortical Kilosort4 units (3,520 against 520) and a lower single-unit fraction (0.116 against 0.354), but 2.212 times NS's single units (407 against 184), outside the criterion's 1.8 to 2.2. Two of three parts hold; the criterion requires all three and names no partial outcome, so the claim is not reproduced, narrowly (changed from partially reproduced after verification round 1). The E sorting belongs to the 1-hour recording - 250 Kilosort4 units reach an agreement of 0.5 with its ground truth and none with that of the 10-minute 40 kHz recording. Whether the paper's evoked recording in Figures 4 and 5a is this one is asked of a reader (questions/001250.yaml). The criterion says the claim holds under either recording, and the 10-minute 40 kHz recording cannot be tested, so the outcome rests on the assumption that E is the paper's evoked recording.

    Deviations from the paper’s method
    • Only the first 10 minutes of the 1-hour recording has a sorting; the 10-minute 40 kHz recording has none, so the claim is judged on that reading alone.
    • Assumed after verification round 2. E, the first 10 minutes of the 1-hour 20 kHz recording, is taken as the paper's evoked recording of Figures 4 and 5. The criterion leaves the evoked recording open and asks for both; the 10-minute 40 kHz recording (E40) has no deposited sorting, so it cannot be tested. The basis is that the deposited E Kilosort4 sorting matches E's ground truth (250 units with an agreement of 0.5 or more) and not E40's (none), and that it reproduces the code's printed median of 0.655 spikes/s (fig4-median-firing-rates). Asked of a reader (questions/001250.yaml).
  • Not reproduced

    Because sorting favours highly active units, mean firing rates in most layers are overestimated three to four times by sorted spike trains compared with the ground truth.

    Sorted Kilosort4 single-unit rates exceed the true NS rates in four of five layers, by 3.23 (layer 5) and 4.30…

    Results, Biological factors of sorting failures, paragraph 4; Supplementary figure "Ground truth firing rate distribution"supp6-sorted-rates-overestimated
    From the paper

    Notably, the bias for high firing units led to mean firing rates in most layers being overestimated by a factor of three to four from sorted spike trains compared to the ground truth

    Result

    Sorted Kilosort4 single-unit rates exceed the true NS rates in four of five layers, by 3.23 (layer 5) and 4.30 (layer 4) within 2.7 to 4.4, and by 4.55 (layer 6) and 5.27 (layer 2/3) beyond it; layer 1, with one sorted unit, gives 0.52. Two of five layers fall in the range, not a majority; the bootstrap variant gives the same count. The overestimation the statement describes is present, larger than three to four times in two layers.

  • Not reproduced

    Pyramidal neurons, 91% of the ground truth, are under-represented after sorting by about a factor of two in every layer except layer 5, where they are over-represented by about two; most interneurons are represented in proportion, but rare interneuron types are over-represented by 2.9 to 8.1 by some sorters, mainly Kilosort 1 to 2.5.

    The 1-hour evoked ground truth is 91.2% excitatory.

    Results, Biological factors of sorting failures, paragraph 5; Figure 6g, hfig6gh-selection-bias-layer5-pyramidal
    From the paper

    Excitatory pyramidal neurons, which made up 91% of the ground truth population ( Fig. 6g ), were consistently underrepresented across all layers by approximately a factor of 2, except in layer 5, where they were over-represented by the same factor ( Fig. 6h , ratios in blue; Fisher’s exact test, two-tailed, p < 0.05). In contrast, most interneurons were proportionally represented relative to the ground truth, except for rare interneuron types, which were over-represented by factors ranging from 2.9 to 8.1 by some spike sorters, particularly Kilosort (1 to 2.5)

    Reported statistics
    • Fisher's exact test, two-tailed, p < 0.05
    Result

    The 1-hour evoked ground truth is 91.2% excitatory. With the 1-hour sortings layer 5 excitatory neurons are over-represented by every sorter (ratios 1.43 to 2.20, p < 1e-6), but the other excitatory layers are not all at 0.67 or below with p < 0.05 for any sorter (Kilosort4 has layer 6 at 0.81); with the 10-minute sortings layer 5 is at 1.5 or more for Kilosort 3, 4 and herdingspikes only and no sorter meets the criterion. Both durations give the same outcome. The interneuron part holds in both, as at least one of Kilosort, 2 and 2.5 lies within 2.6 to 8.9. With the 1-hour sortings the largest interneuron-type ratios are 9.98 (Kilosort2.5, INH L4 cSTUT, 1 unit; outside), 8.07 (Kilosort2) and 4.12 (Kilosort); with the 10-minute sortings 13.3 (Kilosort, 324 units of 17 L5 cNAC neurons; outside), 4.01 (Kilosort2) and 2.90 (Kilosort2.5). Apart from Kilosort's 13.3, each rests on 1 to 9 units. The measured values are the excitatory share and the largest interneuron ratio of Kilosort 1 to 2.5 with the 1-hour sortings (9.98, outside 8.1 +- 0.81; corrected from 8.07 after verification round 2).

    Deviations from the paper’s method
    • Sorted units whose scores are all 0 have no best match and are dropped (at most 37 of 2,665, Kilosort, 10 minutes).
    • After verification round 1, p < 0.05 is required only of the excitatory layers whose ratio is 1.5 or more or 0.67 or less ("for those that differ"); the earlier rule, p < 0.05 in every layer, is shown and gives the same. The Kilosort2 10-minute sorting of E is scored over its 240 s.

Blocked4

  • Blocked

    For the biophysical models the sorters well-sort similarly low proportions of ground truth neurons, on average 15% of the neurons within 50 um of the electrodes.

    Both readings of the criterion sum the 10-minute 40 kHz evoked recording, and reading (a) also S, and neither…

    Data missing from the datasetResults, Biological factors of sorting failures, paragraph 2; Figure 6a, buses data from outside the datasetfig6ab-biophysical-accuracy-15-percent
    From the paper

    However, the sorters produced similarly low proportions of well-sorted ground truth neurons for the biophysical models ( Fig. 6a ), on average 15% of the neurons within 50 µm of the electrodes across the simulations

    Reported statistics
    • well-sorted proportion across the six sorters: chi-square, chi2(5, N = 3,190) = 4.9, p = 0.43
    Result

    Both readings of the criterion sum the 10-minute 40 kHz evoked recording, and reading (a) also S, and neither has a deposited sorting. On what is available, the mean well-sorted fraction over the six sorters is 0.093 for NS alone (goodness-of-fit p = 0.043) and 0.070 for NS with the first 10 minutes of the 1-hour E (p = 0.42; the Kilosort2 sorting of E scored over its 240 s); neither substitutes for the criterion's readings, since S's near-perfect accuracies would raise reading (a).

  • Blocked

    The dense probe gives five times fewer neurons sorted with above 80% accuracy than the Neuropixels probe, on average 3% against 15% across sorters.

    Depends on fig6ab-biophysical-accuracy-15-percent for the Neuropixels value, which is blocked.

    Data missing from the datasetResults, Biological factors of sorting failures, paragraph 3; Figure 6a, bfig6-dense-probe-lower-accuracy
    From the paper

    We found that the dense probe produced five times fewer neurons sorted with above 80% accuracy across spike sorters than the Neuropixels probe (on average 3% vs. 15%)

    Result

    Depends on fig6ab-biophysical-accuracy-15-percent for the Neuropixels value, which is blocked. The dense probe value can be computed in part. With depths 2 and 3 the mean well-sorted fraction is 0.0225 (0.0196 as deposited, the depth 1 neurons scored against depth 2's sortings), below the expected 0.03 +- 0.003. Only one depth 3 neuron is well sorted, by Kilosort2. In a scan of lags from -100 to +100 ms (data check, every sorter since verification round 2), no depth 3 sorting's coincidence rate with any of the three dense probe ground truths rises more than 0.011 above its median over lags, so their scores are unreliable.

  • Blocked

    A fractional regression of Kilosort4 sorting accuracy on 21 neuron features fits the data (R2 = 0.42 spontaneous, 0.34 evoked) and finds seven significant features in both regimes; accuracy rises with firing rate and spike spatial extent, is higher for pyramidal cells and in layer 5, and falls with distance to the nearest electrode.

    Two of the 21 features, snr and spatial_extent of each ground truth neuron, need the neurons' waveforms over…

    Too large to analyseResults, Biological factors of sorting failures, paragraph 4; Figure 6c-ffig6c-f-accuracy-predictors
    From the paper

    The model provided a good fit to the data ( Fig. 6 , R 2 = 0.42 and R 2 = 0.34 in the spontaneous (c) and evoked (d) regimes respectively) and identified seven significantly predictive features out of 21 in both regimes. Accuracy improved as neuronal firing rates increased and spike spatial extent (or ‘footprint’ [ 6 ]) expanded. It was also higher for pyramidal cells compared to interneurons and in layer 5 compared to other cortical layers. Sorting accuracy decreased when neuron’s distance to the nearest electrode increased

    Result

    Two of the 21 features, snr and spatial_extent of each ground truth neuron, need the neurons' waveforms over the full 10 minutes of NS and of the 1-hour E (1,388 and 1,836 neurons), a larger computation than fig5ef-curation-precision-recall's, which is already estimated beyond the limit. After verification round 1 the other 19 features were run. In both regimes and both fits (the criterion's alpha 0 fit and an identified unpenalised refit) firing rate is positive (refit 1.09 spontaneous, 0.77 evoked, p < 1e-4), synapse class (excitatory) positive (0.22 and 0.23, p = 0.083 and 0.056), layer 5 positive (0.57 and 0.45, p < 1e-4) and distance negative (-1.23 and -1.32, p < 1e-4), so four of the five signs of the claim hold. The 19-feature test R2 is 0.307 and 0.279 (paper 0.42 and 0.34 with 21 features). In the evoked regime none of the alpha 0 fits converged within the paper's 100 iterations. The sign of spatial extent and the 21-feature R2 and count, which decide the outcome, cannot be computed.

    Deviations from the paper’s method
    • The part run uses statsmodels 0.15.0 (the paper used 0.14.2), an intercept (a standard choice), and an identified refit for the Wald p values, as the 19-feature indicator design of the code is rank-deficient.
  • Blocked

    The ground truth neural manifold has a ring-like geometry tracking stimulus direction; spike sorting distorts it for all sorters, but the recent sorters (Kilosort2 to 4) still preserve the stimulus mapping.

    The responses are spike counts in each 200 ms presentation of 8 directions, so the analysis needs each…

    Metadata insufficientResults, Spike sorting degrades stimulus representation, paragraphs 1 and 2; Figure 7afig7a-ring-manifold
    From the paper

    The ground truth neural manifold exhibited a ring-like geometry ( Fig. 7a ), which continuously reflected changes in the stimulus direction across trials. Spike sorting distorted the manifold’s geometry for all spike sorters, but the most recent sorters still preserved stimulus mapping (from Kilosort2 to 4)

    Result

    The responses are spike counts in each 200 ms presentation of 8 directions, so the analysis needs each presentation's time and direction. No file of the dandiset holds a stimulus table, trial intervals or stimulus metadata (stimulus/presentation, intervals and processing are empty in sub-002, sub-002-fitted and sub-npx-evoked-sf-40Hz). The paper's code rebuilds the schedule from task parameters in its scripts (igeom.get_task_parameters and get_stimulus_labels); the claims file does not name it as an input, so it was not used.

Not tested in a notebook 11

4 data missing from the dataset, 3 too large to analyse, 4 metadata insufficient

Blocked11

  • Blocked

    Most units sorted from Buccino's synthetic traces are single units, four times more than in vivo.

    The claim analyses the Kilosort4 sorting of Buccino's synthetic recording S.

    Data missing from the datasetResults, Model predicts low yield, quality and biases, paragraph 2; Figure 5auses data from outside the datasetfig5a-synthetic-mostly-single-units
    From the paper

    In contrast with the in vivo yield, the majority of units sorted from the synthetic traces were ‘single-units’, four times more than in vivo

    Reported statistics
    • chi-square, chi2(1, N = 740) = 4.0, p = 0.042
    Result

    The claim analyses the Kilosort4 sorting of Buccino's synthetic recording S. The dandiset holds S's traces and 250 ground truth units (sub-mearec-synthetics-buccino-rep) but no sorting of it; the paper's sortings of S are not public elsewhere. Re-sorting with Kilosort 4 was not attempted.

  • Blocked

    Down-sampling the simulated traces by two to shorten spikes improves the Kilosort4 single unit yield only marginally, by 6%.

    NS-2X, NS with every second sample kept, has neither traces nor sortings in the dandiset, and is not public…

    Data missing from the datasetResults, Model predicts low yield, quality and biases, paragraph 5; Figure 5a (NS-2X)fig5a-downsampling-small-gain
    From the paper

    We applied this approach but observed only a marginal 6% improvement in single-unit yield

    Result

    NS-2X, NS with every second sample kept, has neither traces nor sortings in the dandiset, and is not public elsewhere.

  • Blocked

    In Buccino's synthetic model, Kilosort4 produces more single units than there are modelled neurons, which indicates redundant units.

    No sorting of S is in the dandiset (see fig5a-synthetic-mostly-single-units).

    Data missing from the datasetResults, Model predicts low yield, quality and biases, paragraph 6; Figure 5b (blue)uses data from outside the datasetfig5b-synthetic-redundant-units
    From the paper

    In Buccino’s full synthetic model, Kilosort4 produced more ‘single-units’ than the number of modeled neurons, indicating the production of redundant units

    Result

    No sorting of S is in the dandiset (see fig5a-synthetic-mostly-single-units).

  • Blocked

    A logistic regression on unit quality metrics classifies good against degraded Kilosort4 single units with 89% and 93% precision and 61% and 55% recall in the spontaneous and evoked simulations.

    The features are SpikeInterface quality metrics (snr, silhouette, amplitude cutoff, sd_ratio and others) and…

    Too large to analyseResults, Model predicts low yield, quality and biases, paragraph 8; Figure 5e, ffig5ef-curation-precision-recall
    From the paper

    The model achieved 89% ± 2% (95% CI) and 93% ± 2% precision and 61% ± 3% and 55% ± 2% recall in the spontaneous ( Fig. 5e ) and evoked simulations (f) respectively

    Result

    The features are SpikeInterface quality metrics (snr, silhouette, amplitude cutoff, sd_ratio and others) and mad_ratio, which need waveforms, spike amplitudes on all spikes and principal components over the full 10 minutes of NS and E. Timed on 30 s of NS (184 single units), sparsity, waveforms, amplitudes and principal components took 27, 41, 25 and 53 s, mostly streaming (about 45 MB/s). Scaled to 10 minutes this is about 40 to 50 minutes for NS and 20 to 25 for E, some 70 minutes in all, beyond the 60-minute limit for one notebook. Splitting it over notebooks, with development on a subset and a full run, was judged not to fit the five-hour run beside the other claims. The data are in the dandiset; the timing was run outside the notebook and decides nothing else.

  • Blocked

    The new mad_ratio metric has the largest correlation with unit sorting accuracy (R = -0.46), and the firing rate statistics and the spike trough variability metrics (mad_ratio, sd_ratio) are the key significant predictors of a good unit.

    Needs the NS quality metrics of fig5ef-curation-precision-recall (estimated 40 to 50 minutes of streaming and…

    Too large to analyseResults, Model predicts low yield, quality and biases, paragraph 8; Figure 5gfig5g-mad-ratio-and-firing-predict-quality
    From the paper

    We also introduced a new metric, which we called the “mad_ratio” (see Methods), which better reflected contamination by multiple units, displaying the largest correlation with unit sorting accuracy ( R = − 0.46). The model offered the additional insight that two key predictive features of a good unit are its firing rate statistics ( Fig. 5g , including firing rate and range, p < 0.001) and the variability of its spike troughs compared to background noise variability (mad_ratio and sd_ratio, p < 0.001)

    Reported statistics
    • weights of firing rate, firing range, mad_ratio and sd_ratio: logistic regression weight, Wald test, p < 0.001
    Result

    Needs the NS quality metrics of fig5ef-curation-precision-recall (estimated 40 to 50 minutes of streaming and computation for NS alone), not run.

  • Blocked

    A CEBRA embedding of full waveforms with a k-nearest neighbour classifier gives better recall (82% and 90%) but lower precision (61% and 55%) than the logistic regression in the spontaneous and evoked regimes.

    Needs the waveforms and quality metrics of fig5ef-curation-precision-recall, on which it depends, plus CEBRA…

    Too large to analyseResults, Model predicts low yield, quality and biases, paragraph 9; Supplementary figure "Single-unit yield and quality ...", panels c, dsupp5-cebra-knn-curation
    From the paper

    The model achieved better recall (82%, ± 3% and 90% ± 2% for the spontaneous ( Supplementary Fig. 5c ) and evoked (d) regimes respectively) but lower precision (61% ± 3% and 55% ± 3%) than the logistic regression

    Result

    Needs the waveforms and quality metrics of fig5ef-curation-precision-recall, on which it depends, plus CEBRA fits over 100 splits; not run.

  • Blocked

    On Buccino's synthetic simulation most spike sorters detect most neurons, with accuracies ranging from 50% for herdingspikes to 99% for Kilosort2.

    No sorting of S is in the dandiset, for any of the six sorters.

    Data missing from the datasetResults, Biological factors of sorting failures, paragraph 2; Figure 6auses data from outside the datasetfig6a-synthetic-accuracy-range
    From the paper

    As previously reported, for the synthetic simulation [ 16 ] most spike sorters detected most neurons with accuracies ranging from 50% for herdingspikes to 99% for Kilosort2

    Result

    No sorting of S is in the dandiset, for any of the six sorters.

  • Blocked

    Spike sorting significantly reduces the information capacity of the population, on average by 50% across sorters, from 25% above the lower bound.

    As fig7a-ring-manifold, no stimulus table.

    Metadata insufficientResults, Spike sorting degrades stimulus representation, paragraph 3; Figure 7bfig7b-sorting-halves-capacity
    From the paper

    Distortions in manifold geometry were associated with significant reductions in information capacity, averaging 50% decrease across spike sorters, from 25% above the lower bound ( Fig. 7b , t(199) ranging from -68 to -24, all p < 0.001, t-test)

    Reported statistics
    • t-test, t(199) from -68 to -24, p < 0.001 (n = 200 bootstraps per population)
    Result

    As fig7a-ring-manifold, no stimulus table.

  • Blocked

    Randomly under-sampling ground truth neurons to the sorters' yields does not change information capacity, but also matching the neuron type distribution of the sorted units reduces it by an average 21% across sorters.

    As fig7a-ring-manifold, no stimulus table; it also depends on fig7b-sorting-halves-capacity.

    Metadata insufficientResults, Spike sorting degrades stimulus representation, paragraph 4; Figure 7d-ffig7f-undersampling-no-loss-selection-bias-loss
    From the paper

    Under-sampling ground truth neurons to match sorting yields neither disrupted the manifold’s structure nor its information capacity (example for Kilosort4, Fig. 7d , and all sorters in f, red boxes vs. red line, t(199) ranging from -0.71 to -0.02, all p > 0.47, t-test). However, also matching neuron type distribution to that of sorted units visibly degraded the manifold structure and its information capacity by an averaged 21% across sorters

    Reported statistics
    • random under-sampling against ground truth: t-test, t(199) from -0.71 to -0.02, p > 0.47
    • type-matched sampling against ground truth: t-test, t(199) from -17 to -8, p < 0.001
    Result

    As fig7a-ring-manifold, no stimulus table; it also depends on fig7b-sorting-halves-capacity.

  • Blocked

    Good and degraded sorted units differ in type distribution; good units have on average 37% lower capacity than the ground truth, and degraded units, matched to the good units' type distribution, a further 12% lower for most sorters.

    As fig7a-ring-manifold, no stimulus table; it also depends on fig7b-sorting-halves-capacity.

    Metadata insufficientResults, Spike sorting degrades stimulus representation, paragraph 5; Figure 7gfig7g-assignment-bias-capacity
    From the paper

    Unit type distributions differed significantly between biased and good units across spike sorters ( p < 0.001, Fisher exact test with Monte Carlo simulations) ... On average, the information capacity of good units was 37% lower than the ground truth across spike sorters ( Fig. 7g , red boxes vs. red line, t(199) ranging from -0.31 to -15, all p < 0.001, t-test). Degraded units exhibited even lower capacity, averaging a 12% decrease from good units’ capacity across most sorters (Kilosort4, 2.5, 1, and herdingspikes)

    Reported statistics
    • type distributions, degraded against good units: Fisher exact test with Monte Carlo simulations, p < 0.001
    • good units against ground truth capacity: t-test, t(199) from -0.31 to -15, p < 0.001
    Result

    As fig7a-ring-manifold, no stimulus table; it also depends on fig7b-sorting-halves-capacity.

  • Blocked

    The capacity loss comes with larger direction manifold radii (6% on average, except a 3% decrease for Kilosort), larger dimensions (6% on average, except a 19% decrease for Kilosort and Kilosort2) and slightly more correlated centroids (1% for Kilosort3, 2, 1 and herdingspikes).

    As fig7a-ring-manifold, no stimulus table; it also depends on fig7b-sorting-halves-capacity.

    Metadata insufficientResults, Spike sorting degrades stimulus representation, paragraph 6; Figure 7h-jfig7h-j-manifold-geometry
    From the paper

    Except for Kilosort which showed a 3% decrease, direction mani-folds’ radii increased by an averaged 6% across sorters ( Fig. 7h , t(199) ranging from -87 to 0.18, all p < 0.001, t-test). Except for Kilosort and Kilosort2 which displayed a 19% decrease in direction manifold’s dimension, dimension also increased by an averaged 6% across sorters (i, t(199) ranging from -59 to 234, all p < 0.001). A marginal but significant increase in center correlation of 1% was observed for Kilosort3, 2, 1, and Herdingspikes

    Reported statistics
    • radius, sorted against ground truth: t-test, t(199) from -87 to 0.18, p < 0.001
    • dimension, sorted against ground truth: t-test, t(199) from -59 to 234, p < 0.001
    Result

    As fig7a-ring-manifold, no stimulus table; it also depends on fig7b-sorting-halves-capacity.

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Published code disagreesIn the paper's code (notebooks/1_results/fig2_M_amplitude_npx_DONE.ipynb, commit 6e9af03), the Marques-Smith recording is overwritten by the spontaneous model before the peak amplitudes are computed (`RecNV = preprocess(RecNS, FREQ_MIN)`), so the printed maximal amplitude and per-site amplitudes labelled Marques-Smith are the model's; the notebook then loads saved figure data, so whether the published panel is affected cannot be told from the code.#
  • Methods not availableWhich evoked recording enters Figures 4 and 5a is not stated. The Figure 6 legend names the 10-minute 40 kHz recording for panels a and b and the 1-hour 20 kHz recording for d, f, g and h; Figures 4 and 5 name none. The deposited evoked sortings are of the first 10 minutes of the 1-hour recording (250 Kilosort4 units reach an agreement of 0.5 with its ground truth, none with the 40 kHz one), and they reproduce the code's printed median rate of 0.655 spikes/s. This attempt assumes that recording; could the authors confirm it?#

Questions about the claims 2

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • openasked 2026-11-05about fig5a-evoked-more-units

    Is the evoked simulation of Figures 4 and 5a the first 10 minutes of the 1-hour 20 kHz recording (sub-002-fitted), not the 10-minute 40 kHz recording? The criteria of fig5a-evoked-more-units, fig4a-lognormal-firing-rates and fig4-median-firing-rates leave the evoked recording open and say the code uses the 10-minute sortings of its "npx_evoked" config, which reads as the 40 kHz recording. If the code's "npx_evoked" config is the 1-hour recording sorted over its first 10 minutes, the open choice is settled and the 40 kHz reading drops out. The same bears on which five experiments enter chi2(4, N = 5,241) in fig5a-single-unit-fraction-differs.

    Passage. The 10-minute evoked simulation at 40 kHz was used in panels a and b. To link neuron selection biases to stimulus representation quality (Fig. 7), the 1-hour evoked simulation at 20 kHz was analyzed in panels d, f, and g-h (Figure 6 legend). Figures 4 and 5 name no evoked recording. The claims file quotes the code's fig4_A_B_C_firing_rate_ks4, cell 13, as printing 0.655 +- 0.083 Hz for the evoked simulation.

    Why it matters. The first 10 minutes of the deposited 1-hour recording give exactly the code's printed 0.655 +- 0.083 (fig4-median-firing-rates, reading a), and its 3,520 cortical Kilosort4 units fit the paper's N = 5,241 for M, NS, NS-2X, E and S (which implies E of about 3,489), as the verifier of round 1 noted. The deposited E sorting matches the 1-hour ground truth (250 Kilosort4 units with an agreement of 0.5 or more) and not the 40 kHz one (none). The 40 kHz recording has no deposited sorting, so the claims that leave the choice open are tested only on the 1-hour reading; if the reader confirms it, those outcomes rest on the paper's own recording and no longer on one of two readings. No outcome of this attempt changes.

    No reader has answered it yet.
  • openasked 2026-11-05about fig4a-lognormal-firing-rates

    The criteria of fig4a-lognormal-firing-rates, fig4-median-firing-rates, fig5cd-most-units-degraded and fig5a-evoked-more-units describe the code's "npx_evoked" config as 10 minutes and leave the evoked recording open between the 10-minute 40 kHz recording and the first 10 minutes of the 1-hour 20 kHz recording. Does "10 minutes" there refer to the length sorted (the first 10 minutes of the 1-hour recording), not to the 10-minute 40 kHz recording? If so, the evoked recording of Figures 4 and 5 is the 1-hour one and the open choice drops out.

    Passage. The 10-minute evoked simulation at 40 kHz was used in panels a and b. To link neuron selection biases to stimulus representation quality (Fig. 7), the 1-hour evoked simulation at 20 kHz was analyzed in panels d, f, and g-h (Figure 6 legend). Figures 4 and 5 and their legends name no evoked recording. Methods - To minimize computational cost, we analyzed the first 10 minutes of all recordings from cortical electrode sites.

    Why it matters. Raised by the round 2 verifier. The deposited evoked sortings are of the first 10 minutes of the 1-hour recording (250 Kilosort4 units reach an agreement of 0.5 with its ground truth, none with the 40 kHz one) and reproduce the code's printed 0.655 spikes/s. The criteria ask for both recordings, and the 40 kHz one has no sorting, so these outcomes are marked as resting on an assumption. If the reader reads "10 minutes" as the sorted length, the assumption becomes the claims file's own reading. No outcome of this attempt changes.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Spike sorting biases in a detailed cortical model (Laquitaine et al. 2024)

Tests the findings of Laquitaine, Imbeni, Tharayil, Isbister and Reimann (bioRxiv 2024) on dandiset 001250, which holds simulated Neuropixels and dense probe recordings of a cortical column model with their ground truth spikes, the in vivo recordings they are compared with, and the paper's sortings. It checks the validation of the simulated traces against in vivo, the firing rates and yields of the sorted units, their accuracy against the ground truth, and the selection bias of the sorters. The manifold analyses of Figure 7 cannot be run, as the dandiset holds no stimulus table. All files

Environment: Python 3.13, 113 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-05
    Agreed with 36 of 39 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The handover of the first run (executed notebook with the conclusions and summary removed, the helper module and the claims file); the verifier also checked the archive's asset list and file contents for the blocked claims and tested helper functions on synthetic inputs.
    • ground-truth-neuron-counts: the verifier’s outcome was “Not reproduced”. The counts are exact, 1388, 1836 and 1552, all within 50 um. But 78 NS units and 213 units of the 1-hour E are silent in the first 600 s. The criterion requires that every unit spikes.
    • fig4a-yield-deep-layers: the verifier’s outcome was “Not reproduced”. M has one single unit in layer 2/3, where the criterion requires none. M's L5/L4 ratio is exactly 20.0. The NS and E parts hold (narrow).
    • fig5a-evoked-more-units: the verifier’s outcome was “Not reproduced”. Total units rise 6.77-fold and the single fraction drops (0.116 against 0.354). But single units rise 407/184 = 2.21, outside 1.8-2.2 (narrow). The E40 reading is blocked, no sorting. 2.21 is printed next to '(1.8 to 2.2)' without noting that it misses (problem 9).
  • Round 2
    2026-11-05
    Agreed with 39 of 39 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook of the revision after round 1, with its conclusions and summary, the helper module, the claims file and the attempt record.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • Assumed after verification round 2. E, the first 10 minutes of the 1-hour 20 kHz recording, is taken as the paper's evoked recording of Figures 4 and 5. The criterion leaves the evoked recording open and asks for both; the 10-minute 40 kHz recording (E40) has no deposited sorting, so it cannot be tested. The basis is that the deposited E Kilosort4 sorting matches E's ground truth (250 units with an agreement of 0.5 or more) and not E40's (none), and that it reproduces the code's printed median of 0.655 spikes/s (fig4-median-firing-rates). Asked of a reader (questions/001250.yaml).fig4a-lognormal-firing-rates fig4-median-firing-rates fig4bc-lower-median-narrower-distribution supp4-other-sorters-firing-rates fig5a-evoked-more-units fig5cd-most-units-degraded
  • E is the first 10 minutes of the 1-hour recording.fig4-median-firing-rates fig4bc-lower-median-narrower-distribution supp4-other-sorters-firing-rates fig5cd-most-units-degraded
  • The maxima are streamed over the whole first 600 s in 2.5 s blocks, each filtered with 50 ms margins (verifier round 1); the 60 s blocks are shown as a variant.fitted-trace-maximal-amplitude
  • Traces are six 10 s blocks of the first 10 minutes (60 s per recording), not 10 minutes.fig2m-peak-amplitude-increases-with-depth
  • E is the 1-hour evoked recording (sub-002-fitted), as in the code; the 10-minute recording is shown and gives the same.fig2m-peak-amplitude-increases-with-depth
  • The Horvath files' scale is inconsistent (finding); H in counts is used for DS against H, as the fitted dense model's noise matches H in counts (median 28.3 against 28.7) and not at 0.195 uV per count (5.6). The comparison with H is reported and does not decide the outcome.fig2m-peak-amplitude-increases-with-depth
  • Traces are 60 s per recording (six 10 s blocks of the first 10 minutes), not 10 minutes, so the minimum over 1 s segments is over 60 segments, not 600.fig2np-noise-increases-with-depth
  • The ANR extremes use the minimum and maximum of the preprocessed traces over the whole first 600 s, divided by each site's median absolute deviation from the 60 s blocks (verifier round 1); the histograms use the 60 s blocks.fig2q-anr-within-vivo-range
  • Spectra are Welch averages over six 10 s blocks, not the first 10 minutes.fig2r-power-law-spiking-band
  • Traces are 60 s per recording, not 10 minutes.fig2s-v-ap-power-and-scaling-increase-with-depth
  • The claims file does not say whether "the scaling slope increased" refers to the signed slope or its magnitude; both are shown, and the outcome is partial under both.fig2s-v-ap-power-and-scaling-increase-with-depth
  • Spectra at 1 Hz resolution from six 10 s raw blocks, not 10 minutes; the 0.5 Hz bin is not resolved, so the band is the 1 to 4 Hz bins.supp2-no-slow-oscillations
  • The files hold no soma position; distances are from the electrode of largest amplitude, with the code's soma position as a variant (an outside input). Both give the same outcome.fig3e-amplitude-decay-with-distance
  • Templates are means over each unit's spikes inside the six 10 s blocks (median 43 spikes for NS, 54 for M), not over all spikes of 10 minutes.fig3fg-wavemap-six-profiles
  • The six sites are the site of largest template amplitude and the sites nearest to it (3-D positions for the models), ordered by amplitude ("the six nearest sites", Methods, WaveMap), each 6 ms segment resampled to 50 points (the WaveMap paper's length, a standard choice so that 30 and 40 kHz give vectors of one length) and the concatenated vector scaled to 0 to 1; the UMAP seed is a standard choice, shown with two others. The code's own WaveMap notebook uses other settings (n_neighbors 6, bandpass to 3 kHz, waveform curation) than the Methods; the claims file's criterion is followed.fig3fg-wavemap-six-profiles
  • Louvain is run on UMAP's neighbour graph (python-louvain), as WaveMap does; umap-learn and python-louvain are recent versions, not 0.5.3 and 0.16.fig3fg-wavemap-six-profiles
  • E is the first 10 minutes of the 1-hour recording; the 10-minute 40 kHz recording has no deposited sorting.fig4a-lognormal-firing-rates
  • No value for S (no sorting in the dandiset).fig4-median-firing-rates
  • Assumed after verification round 2. Partially reproduced is used for "every part that can be tested holds and the rest cannot be tested", which the criterion does not provide for (it names no partial outcome). Without this convention the claim would be blocked (data_missing, S) for its untested parts.fig4-median-firing-rates
  • Assumed after verification round 2. Partially reproduced is used for "every part that can be tested holds and the rest cannot be tested", which the criterion does not provide for (it defines partial as the medians or the variances part holding alone, while here both hold and the S part cannot be tested). Without this convention the claim would be blocked (data_missing, S) for its untested parts.fig4bc-lower-median-narrower-distribution
  • The Kilosort2 sorting of E covers 240 s (its last spike), as the Methods say Kilosort2 sorted 4 minutes of the evoked recording, so its rates are counts over 240 s (verifier round 1). The counts of the outcome are unchanged by this.supp4-other-sorters-firing-rates
  • NS-2X and S have no sorting, so readings (a) and (b) are run on M, NS and E only.fig5a-single-unit-fraction-differs
  • NS has 520 cortical Kilosort4 units against the paper's 504.fig5a-single-unit-fraction-differs
  • Assumed after verification round 2. The test part holds; the fraction fails under reading (i), the only one the dandiset allows, and readings (ii) and (iii) need NS-2X. Partially reproduced is used for "one part holds and the other cannot be fully tested", which the criterion does not provide for (it names no partial outcome). Without this convention the claim would be blocked (data_missing, NS-2X) for the fraction.fig5a-single-unit-fraction-differs
  • DS sums depths 2 and 3, as the deposited depth 1 sortings are copies of depth 2's.fig5a-single-unit-counts
  • The contingency chi-square variant gives p = 0.0025 (M, NS) and 5.2e-06 (H, DS).fig5a-single-unit-counts
  • Assumed after verification round 2. Partially reproduced is used for "the counts that can be computed hold and the rest cannot be tested", which the criterion does not provide for (it names no partial outcome). Without this convention the claim would be blocked (data_missing, NS-2X and the depth 1 sortings) for its untested parts.fig5a-single-unit-counts
  • Only the first 10 minutes of the 1-hour recording has a sorting; the 10-minute 40 kHz recording has none, so the claim is judged on that reading alone.fig5a-evoked-more-units
  • DS sums depths 2 and 3 (481 units against the paper's 562), as the deposited depth 1 sortings are copies of depth 2's.fig5a-dense-probe-more-multi-units
  • E's theoretical yield uses the first 10 minutes of the 1-hour recording; the 10-minute recording is shown.fig5b-yield-far-below-theory
  • Assumed after verification round 2. Partially reproduced is used for "every part that can be tested holds and the rest cannot be tested", which the criterion does not provide for (it defines partial as one of its two parts holding, while here both hold for what can be computed). Without this convention the claim would be blocked (metadata_insufficient, DS layers) for its untested parts.fig5b-yield-far-below-theory
  • Agreement scores use SpikeInterface 0.105 (the paper used 0.100.5). After verification round 1 the quality tags are computed over every sorted unit of the sorting, and "partial" looks only at the unit's above-chance neurons, as the claims file defines it; the Kilosort4 numbers are unchanged. The Kilosort2 sorting of E is scored over its 240 s.fig5cd-most-units-degraded
  • The part run uses statsmodels 0.15.0 (the paper used 0.14.2), an intercept (a standard choice), and an identified refit for the Wald p values, as the 19-feature indicator design of the code is rank-deficient.fig6c-f-accuracy-predictors
  • Sorted units whose scores are all 0 have no best match and are dropped (at most 37 of 2,665, Kilosort, 10 minutes).fig6gh-selection-bias-layer5-pyramidal
  • After verification round 1, p < 0.05 is required only of the excitatory layers whose ratio is 1.5 or more or 0.67 or less ("for those that differ"); the earlier rule, p < 0.05 in every layer, is shown and gives the same. The Kilosort2 10-minute sorting of E is scored over its 240 s.fig6gh-selection-bias-layer5-pyramidal

Provenance

Attempt record
laquitaine-2024-01
Paper
Preprint
Date
2026-11-05
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:001250 (on DANDI)
Version
0.251012.1648 (doi:10.48324/dandi.001250/0.251012.1648)
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-13

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Other data and code used 1

What the attempt used that is not in the dataset: other data, and the paper’s code. Each is as the attempt’s record describes it.

  • steevelaquitaine/spikebias GitHub

    The soma position of cell 3754013 (`CELL_POS`), used as a variant for the distances of fig3e-amplitude-decay-with-distance, from the notebook notebooks/1_results/fig3_D_spike_spatial_variation_DONE.ipynb of the paper's code.

    Source as recorded: https://github.com/steevelaquitaine/spikebias at commit 6e9af03b81c3892aafa94b2d10b724ef59fdb247

Badges for this paper

Encore: 7 findings reproduced, Laquitaine et al. 2024

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/laquitaine-2024/"><img src="https://encorescience.org/badge/papers/laquitaine-2024.svg" alt="Encore: 7 findings reproduced, Laquitaine et al. 2024"></a>

Or as Markdown:

[![Encore: 7 findings reproduced, Laquitaine et al. 2024](https://encorescience.org/badge/papers/laquitaine-2024.svg)](https://encorescience.org/papers/laquitaine-2024/)

The same numbers are in this page’s JSON, under badge (how it is counted).