Datasets
Not attempted yet. These are the claims read from the paper, which an attempt will test; next in the pipeline: attempt.
Claims 23
From the paper Identifying natural images from human brain activity · claims file · checked 2026-11-10: ready
For subject S1, the image seen was identified correctly for 92% (110 of 120) of the repeated-trial voxel activity patterns from 120 novel natural images, against chance of 0.8%.
From the paper
For this subject, 92% (110/120) of the images were identified correctly (subject S1), whereas chance performance is just 0.8% (1/120)
Criterion
The pipeline of the opening comment (P1 to P5) on S1's 1,750 model estimation and 120 identification repeated-trial responses. The value must hold under one of the readings of O1 and O5; every combination is shown.
For subject S2, 72% (86 of 120) of the images were identified correctly from repeated-trial patterns.
From the paper
For a second subject, 72% (86/120) of the images were identified correctly (subject S2)
Criterion
As fig3-s1-repeated-120, for S2.
Identification from single-trial voxel activity patterns was 51% (834 of 1,620) for S1 and 32% (516 of 1,620) for S2, against chance of 0.8%.
From the paper
Single-trial performance was 51% (834/1620) and 32% (516/1620) for subjects S1 and S2, respectively (Fig. 4a); once again, chance performance is just 0.8% (13.5/1620)
Criterion
Single-trial responses are BRS amplitudes per trial with the HRF from the repeated-trial analysis, all trials of the identification runs used, standardized per session (Supplementary Methods 1, 3 and 4), giving 1,620 patterns per subject; each is identified among the 120 images by P5. The models and voxel selection follow O6, readings (a) and (b); the value must hold under one reading, with O1 and O5 as in fig3-s1-repeated-120.
The estimated noise ceilings suggest that the lower performance of S2 is due to intrinsically noisier data; the ceilings are near 99% for both subjects with repeated trials, and about 80% (S1) and 64% (S2) with single trials.
From the paper
The noise ceiling estimates suggest that the difference in performance across subjects is due to intrinsic differences in the level of noise
Criterion
Noise ceiling as Supplementary Methods 7 gives it. For each of the 120 images, 25 simulations; in each, the measured pattern is the mean of a random sample of the correct image's single-trial patterns, each candidate's predicted pattern the mean of a random sample of its own single-trial patterns, and the most correlated candidate is chosen; the ceiling is the percentage of successes. The values are read from the figure, no sentence gives them. Open are the voxels and the sample size. Voxels, the 500 selected for identification (P5). Sample size, readings (a) a bootstrap sample with replacement of the size of the available trials (13, or 14 for an image among the first 6 trials of a run, which the single-trial analysis keeps) for the repeated-trial ceiling and of size 1 for the single-trial ceiling, (b) without replacement, same sizes. Reproduced when, under one reading, the four values are within tolerance and S2's single-trial ceiling is below S1's, as S2's performance is (the paper's argument, read from the figure; no test is reported).
For S1 with repeated trials, performance declined only from 92% to 82% as the set size rose from 100 to 1,000 images.
From the paper
As set size increased tenfold from 100 to 1,000, performance only declined slightly, from 92% to 82% (subject S1, ... repeated trial)
Criterion
P6 with the paper's 999-image library, the predicted patterns for the library images coming from the S1 models of fig3-s1-repeated-120. The library images are not deposited and no source is given beyond the image collections of the Methods; without them the claim cannot be tested as the paper did it.
Extrapolated, performance falls to 10% at set sizes of 10^11.3 (S1, repeated trial), 10^7.3 (S2, repeated), 10^5.5 (S1, single trial) and 10^3.5 (S2, single).
From the paper
Extrapolation of these measurements (see Supplementary Methods) suggests that performance for this subject would remain above 10% even up to a set size of 1011.3 images
Criterion
The extrapolation of P6 over the 999 library images, the set size at which the mean of f(m,s) over patterns reaches 0.1. Tolerances are 10% of the printed exponent, since the paper reports and compares these set sizes as powers of ten (10% of the set size itself would be far below the precision of one printed decimal of the exponent). Needs the library of fig4b-set-size-1000.
A retinotopy-only model, capturing only the location and size of each voxel's receptive field, falls to 10% correct at a set size of 10^5.1 images, against 10^9.5 for the Gabor wavelet pyramid model (repeated trials, averaged across subjects); it is worse for each subject, with single trials too.
From the paper
Performance for this retinotopy-only model declined to 10% correct at a set size of just 105.1 images, whereas performance for the Gabor wavelet pyramid model did not decline to 10% correct until 109.5 images were included in the set
Criterion
Retinotopy-only model as Supplementary Methods 8 gives it, two channels, the absolute spatially-weighted luminance and the spatially-weighted contrast with weights from the Gaussian fitted to the best initial model's envelope, at the original resolution, fitted by the gradient descent of P2; voxels selected by its own predictive power (Supplementary Methods 7). How the subjects are averaged is open. Readings are (a) the mean of the two subjects' performance curves, then the set size at 10%, (b) the mean of the two exponents; Supplementary Figure 5 gives 11.3 and 7.3 for the GWP model and 7.0 and 3.8 for the retinotopy-only model, whose means (9.3, 5.4) are not the printed 9.5 and 5.1, so (a) is the better supported. Reproduced when, under one reading, both values are within tolerance and the retinotopy-only exponent is below the GWP exponent for each subject and for repeated and single trials (Supplementary Figure 5 gives 3.7 against 5.5, S1, and 2.5 against 3.5, S2, single trial). Needs the library of fig4b-set-size-1000.
At set size 120 with repeated trials, averaged across subjects, the retinotopy-only model identified 55% of images with spatially-weighted luminance and contrast and 42% with the standard (unweighted) metrics, both below the Gabor wavelet pyramid model.
From the paper
Identification performance was 55% and 42% for the spatiallyweighted metrics and standard metrics, respectively (repeated trial, 120 images, performance averaged across subjects)
Criterion
The retinotopy-only model of fig4c-retinotopy-only-extrapolation, identification by P5 at set size 120 on each subject, the two subjects' percentages averaged. Standard metrics are the mean and SD of pixel luminance within +/-2 SD of the Gaussian G (Supplementary Methods 8). Reproduced when both values are within tolerance and both are below the GWP mean of fig3-s1-repeated-120 and fig4a-s2-repeated-120 computed here.
In constrained versions of the GWP model, both orientation and spatial frequency tuning add to identification (C > A, G > A), spatial frequency more (G > C), and voxel-to-voxel variation in both adds too (F > E, H > E); at 1,000 images the nine models give A 17%, B 22%, C 28%, D 30%, E 51%, F 60%, G 64%, H 62% and I 63%.
From the paper
Both orientation and spatial frequency tuning contribute to identification performance (C > A and G > A), but spatial frequency tuning is relatively more important (G > C). Voxel-to-voxel variation in orientation and spatial frequency tuning also contributes to identification performance (F > E and H > E)
Criterion
The nine models of Supplementary Methods 9 at 64 px, the spatial envelope fixed by the Gaussian of the RF location, channels summed over position, transformed by the 640-grating least-squares map and summed over phase, then flat, ROI-averaged (mean tuning across the voxels of the same area) or individual tuning on each dimension, fitted by P2 over one fixed voxel set selected by the predictive power of "the model that imposed no constraints on orientation and spatial frequency tuning" (Supplementary Methods 7). Which model that is the paper leaves open; readings are (a) model I, which fixes the spatial envelope, (b) the final GWP model of P3. Performance at 1,000 images by P6, averaged across subjects. The figure's p-values (C over A 8e-6, G over A 2e-22, G over C 2e-16, F over E 4e-4, H over E 4e-5) are read from the low-resolution table of panel b; the legend states only that all five are below 0.05. Which unit the sign test pairs (each measured pattern's f(m,1000), pooled over subjects) is a reading, the one the legend's "paired" allows. Reproduced when the five orderings hold with one-tailed sign-test p < 0.05 and at least four of the six values are within tolerance. Needs the library of fig4b-set-size-1000; the orderings at set size 120 can be shown as a variant, which does not decide the outcome.
For 120 novel images seen about two months after the main experiment, 82% (99 of 120) were identified correctly (S1, repeated trials), using the models from the main experiment.
From the paper
In this case 82% (99/120) of the images were identified correctly (chance performance 0.8%; subject S1, repeated trial)
Criterion
The S1 models of fig3-s1-repeated-120, applied to the identification responses of the two later sessions, estimated by the BRS model and standardized within each session (Supplementary Methods 3, Analysis for additional scan sessions); P5 on the 120 images. How the 500 voxels are chosen for these sessions is not stated; readings are (a) predictive power on the main experiment's 120 identification images, (b) predictive power on the later session's images, leaving out the image to be identified, as P5 does. Needs those sessions, which the data set's description does not mention.
For 12 novel images seen more than a year (about 14 months) after the main experiment, all 12 were identified correctly (S1, repeated trials; chance 8%).
From the paper
In this case 100% (12/12) of the images were identified correctly (chance performance 8%; subject S1, repeated trial)
Criterion
As time-two-months, for the single-run session about 14 months later, set size 12, with the same two readings for voxel selection. A tolerance of 10 points allows 11 of 12.
Identification errors tended to occur when the selected image was visually similar to the correct image.
From the paper
Inspection revealed that identification errors tended to occur when the selected image was visually similar to the correct image
Criterion
The paper judged this by inspection and gives no measure. The two image similarity measures the paper itself uses (Supplementary Discussion 1) are the readings, (a) correlation of pixel luminance, (b) correlation of local RMS contrast in 0.6 degree blocks. For each error of fig3-s1-repeated-120 and fig4a-s2-repeated-120, the percentile of the selected image's similarity to the correct image among the correct image's similarities to the other 119 images. The test is fixed here, not by the paper. Reproduced when, under one reading, the errors pooled over subjects have a median percentile above 50 by a one-sided Wilcoxon signed-rank test against 50 at p < 0.05.
Identification performance rises with the number of voxels used and is best at about 500 voxels for both subjects, with repeated and single trials.
From the paper
In all cases optimal performance was achieved using about 500 voxels
Criterion
P5 at set size 120 with 1, 5, 10, 20, 50, 100, 200, 500 and 1,000 voxels (the figure's axis), for S1 and S2, repeated and single trials. "About 500" is not made exact by the paper; the rule here is that, in each of the four conditions, performance at 500 voxels is the highest of the nine or within 3 percentage points of the highest, and performance at 500 is above that at 50. Partially reproduced when this holds in two or three conditions.
The visual areas hold 1331 (V1), 2208 (V2) and 1973 (V3) voxels in S1, and 1513, 1982 and 1780 in S2.
From the paper
No quote recorded.
Criterion
Counts of voxels assigned to each area by the retinotopic mapping (Supplementary Methods 10). Reproduced when all six counts are within tolerance; partially when four or five are.
The fraction of voxels whose best initial model has significant predictive power falls from V1 to V2 to V3 (S1 40%, 31%, 17%; S2 25%, 21%, 13%).
From the paper
Predictive power generally decreased from V1 to V2 to V3, likely reflecting the fact that the Gabor wavelet pyramid model is not optimal for visual areas beyond V1
Criterion
Predictive power of the best initial model (P3, P4), significant at p < 0.01 by the bootstrap (O2), as a percentage of each area's voxels. Reproduced when the order V1 > V2 > V3 holds in both subjects and at least four of the six values are within tolerance; partially when the order holds in both subjects only.
SNR differs greatly between subjects but is similar across V1, V2 and V3 within a subject; the fraction of voxels with SNR above 1.5 is 32%, 30% and 22% in S1 and 18%, 19% and 13% in S2.
From the paper
Although SNR varied greatly across subjects, SNR was fairly consistent for areas V1, V2, and V3 within each subject
Criterion
A voxel's SNR is the median, over its model estimation responses aggregated across sessions, of the absolute response divided by its standard error, from the BRS fits (Supplementary Methods 3). The paper does not say how the standard error of an amplitude is obtained; readings are (a) the ordinary least-squares standard error from the final iteration of the BRS fit after the autoregressive transform, (b) a bootstrap over runs. Reproduced when, under one reading, at least four of the six values are within tolerance and S1's fraction is higher than S2's in every area.
The GWP model characterizes the responses of voxels in V1, V2 and V3 but does poorly for higher areas such as V4.
From the paper
The model was able to characterize responses of voxels in visual areas V1, V2 and V3 (Supplementary Table 1), but it did a poor job of characterizing responses in higher visual areas such as V4
Criterion
The paper shows no V4 result, and its V4 voxels were discarded (Supplementary Methods 10), so V4 voxels can only come from the data set's own ROI labels. Measure from Supplementary Table 1, the percentage of voxels whose best initial model has significant predictive power (p < 0.01, P3, P4, O2), for V4 voxels as labelled in the data set and for V1 to V3. Reproduced when, in both subjects, the V4 percentage is below the V3 percentage (the comparison with V3 is fixed here, not by the paper); the median predictive power per area is reported too.
A representative V1 voxel of S1 (voxel 42205) has its receptive field in the left hemifield just below the horizontal meridian, broadband orientation tuning and high-pass spatial frequency tuning.
From the paper
This receptive field is located in the left hemifield, just below the horizontal meridian ... This receptive field has broadband orientation tuning and high-pass spatial frequency tuning
Criterion
Final GWP model of that voxel (P1 to P3, O5), spatial envelope and grating tuning curves as Supplementary Methods 6 (Calculation of tuning curves) gives them. How the paper numbers voxels is not stated; whether 42205 is an index the data set keeps is the author's to find, and if it is not, the claim cannot be tested. Reproduced when the envelope peak lies left of the vertical meridian and below the horizontal meridian within the central half of the stimulus height (the bound for "just below" is fixed here), the spatial frequency tuning is highest at the highest frequency (2.9 cycles per degree on the figure's axis), and the orientation tuning's maximum is less than twice its minimum (the ratio for "broadband" is fixed here).
The V1-averaged orientation tuning curve is nearly flat and the V1-averaged spatial frequency tuning curve is band-pass; voxels have only a slight orientation bias.
From the paper
The orientation tuning curve is nearly flat ... The spatial frequency tuning curve is band-pass
Criterion
The ROI-averaged tuning curves of Supplementary Methods 9, the mean over V1 voxels of the grating tuning curves, with bootstrap SE across voxels. Which models give the curves is not stated; readings are (a) the final GWP models (Supplementary Methods 6, Calculation of tuning curves), (b) the grating-transformed weights of model I of suppfig8-constrained-models (Supplementary Methods 9). Which V1 voxels are averaged is not stated; readings are (a) all V1 voxels with a final model, (b) the fixed voxel set of suppfig8-constrained-models. The figure is an example and does not name a subject; each subject is shown. Reproduced when, under one reading, the orientation curve's range is under 10% of its mean (the bound for "nearly flat" is fixed here) and the spatial frequency curve peaks at an intermediate frequency, above both its lowest and highest frequency values by more than 2 SE (both bounds fixed here).
Receptive-field angle and eccentricity estimated from the GWP model match those from independent multifocal retinotopic mapping, with discrepancies in eccentricity at the lowest and highest eccentricities.
From the paper
Notice that the MF and GWP angle estimates are well matched ... The MF and GWP eccentricity estimates are generally well matched, but there appear to be systematic discrepancies at the lowest and highest eccentricities
Criterion
GWP angle and eccentricity from the RF location of P3, voxels with predictive power significant at p < 0.01 (as the legend says); multifocal estimates by the vector sum and centre of mass of Supplementary Methods 11, from the separate mapping sessions, pooled across subjects. The paper gives no statistic; the measures fixed here are the circular correlation of angles and the Spearman correlation of eccentricities. Reproduced when both are positive with p < 0.05. Needs the retinotopic mapping data, which the data set's description says are not included.
Receptive-field size increases with eccentricity, and from V1 to V2 to V3.
From the paper
RF size increases with eccentricity and across visual areas, consistent with previous fMRI studies
Criterion
RF size is the extent of +/-2 SD of the Gaussian fitted to the best initial model's envelope (P3); voxels kept when predictive power is significant at p < 0.01 and the RF lies wholly inside the stimulus; pooled across subjects, binned by eccentricity, median per bin with at least 10 voxels (the legend). The bin edges are not given; standard choice, 1 degree bins from 0 to 10 degrees, with 0.5 degree bins as a variant. Reproduced when, for each area, the Spearman correlation of RF size with eccentricity over voxels is positive at p < 0.05, and in most bins shared by the three areas the medians order V1 < V2 < V3 (tests fixed here).
Extending classification to novel images (matching the measured pattern to the most similar of the 1,750 training patterns, then picking the identification image most similar to that training image) works poorly, 1.7% and 0.8% correct with pixel luminance similarity (not above chance) and 5% and 5.8% with local contrast (above chance), for S1 and S2.
From the paper
Identification performance using the pixel luminance metric was 1.7% (2/120) and 0.8% (1/120) for subjects S1 and S2, respectively (repeated trial). These values were not significantly above chance (p ≥ 0.05, one-tailed binomial test). Identification performance using the local contrast metric was 5% (6/120) and 5.8% (7/120) for subjects S1 and S2, respectively (repeated trial). These values were above chance (p < 0.0001, one-tailed binomial test)
Criterion
As Supplementary Discussion 1 gives it. Pattern similarity by Pearson r; image similarity by correlation of pixel luminance, or of local RMS contrast in 0.6 degree blocks (n = 0.6, the best of the values the paper tried). Open are the voxels and the contrast measure. Voxels, readings (a) the 500 voxels of P5, (b) all V1 to V3 voxels of O1. RMS contrast, readings (a) the SD of luminance in the block, (b) that SD over the block mean. With 120 images a tolerance of 10% is less than one image, so the counts are judged instead. Reproduced when, under one reading, each count is within one image of the paper's (2, 1, 6, 7), the luminance results are not above chance (one-tailed binomial p at or above 0.05) and the contrast results are (p < 0.0001); partially when the significance pattern holds but a count is further off. The paper wrote p ≥ 0.05, recorded here as p > 0.05.
Most of the 500 voxels used for identification were located in V1, where predictive power was highest.
From the paper
Most of these voxels were located in area V1 where predictive power was highest (Supplementary Table 1)
Criterion
The 500 voxels of P5 for repeated-trial identification, for each subject, assigned to V1, V2 and V3 as in the data set's ROI labels. Since P5 selects voxels per measured pattern, readings are (a) the voxels selected in more than half of the 120 selections, (b) the 500 voxels ranked by predictive power over all 120 images. "Most" is read as more than half (fixed here). Reproduced when, under one reading, more than half of the voxels are in V1 in both subjects.
Pipeline
- Paper match
- done
- Paper
- done (stored)
- Claims
- done
- Claims check
- done (ready)
- Attempt
- todo
- Questions
- none
- Verified
- none