Papers / Jarzebowski et al. 2026

Jarzebowski et al. 2026 · Preprint

Temporal Gating by Chandelier Cells Encodes Signed Prediction Errors

Przemysław Jarzębowski, Daniel Bendor

Outcomes of 30 claims

  • 21 reproduced
  • 4 partially reproduced
  • 5 not reproduced

Summary: Most of the paper's main findings hold up in this data and in a rebuild of its model. In the recordings, L2/3 and L5 bursting is highest on the first repetition of an image and running raises it, as reported. Omission firing and L5 bursting fall below spontaneous levels only in part, depending on which spontaneous period is used, which the Methods leave open; running did not lower L5 firing during omissions. In the model, the prediction did not silence the neuron under weak sensory input and gain changed the release delay, probably because the model's code and input timings are not available. Two supplementary findings, on novel images and on L5 bursting and rate, did not reproduce.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Jarzebowski & Bendor (2026) from dandiset 000713 and the paper's model 30 Open in Colab

Reproduced21

  • Reproduced

    With L5 IT predictive input and no sensory input, the ChC clamp holds the AIS below threshold and the neuron fires a single gated release spike after the clamp decays, 15 to 20 ms after the time the same L5 IT input could have triggered the L5 ET bAP.

    L5 IT 12 nS and ChC 25 nS without L4, 80 runs.

    Results, Negative prediction error, paragraph 1; Figure 1Ddata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21model-negative-error-delayed-release
    From the paper

    In the absence of additional sensory drive from L4, the AIS cannot escape this clamp until ChC conductance sufficiently decays, at which point the accumulated depolarisation is released as a singlet if the soma remains sufficiently depolarised ( Fig. 1D ). In such case, the L2/3 input arrives to the L5 ET 15–20 ms delayed

    Result

    L5 IT 12 nS and ChC 25 nS without L4, 80 runs. 97.5% of runs spike and all spiking runs fire one spike. Median latency from L5 IT onset (reading a) 17.4 ms, inside 13.5 to 22 ms; from the L5 IT peak (reading b) 9.4 ms, outside. Over the five seeds reading (a) gives 17.1 to 17.9 ms.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • The criterion names two readings of the reference time; the claim holds under reading (a) and not under (b).
  • Reproduced

    A sufficiently strong L4 input during the active ChC clamp overrides it and drives a breakthrough spike, but the L4 conductance needed for a doublet is higher than without a prediction.

    With prediction every run spikes at L4 150 nS and no L4 up to 150 nS gives a doublet under either reading…

    Results, The circuit encodes a continuous error spectrum, paragraph 1; Figure 2Bdata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig2b-breakthrough-doublet-threshold
    From the paper

    When the L4 input was sufficiently strong and arrived during the active ChC clamp window, it overrode the clamp and drove a spike, a breakthrough event, albeit with a higher threshold for producing a doublet relative to a completely unpredicted positive error ( Fig. 2B ).

    Result

    With prediction every run spikes at L4 150 nS and no L4 up to 150 nS gives a doublet under either reading; without it the doublet threshold is 110 nS (expected count 2, reading a) or 90 nS (half the runs, reading b). Searched to 600 nS, the thresholds with prediction are 345 and 260 nS. All five seeds agree (110 to 120 and 90 nS without prediction).

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • The threshold with prediction lies above the 0 to 150 nS plotting range; the range was extended to 600 nS to find it, which changes no comparison.
  • Reproduced

    Delaying either the predictive or the sensory input by 5 ms leaves the model's behaviour the same.

    At L4 60 nS with prediction the expected count is 0.775 at 0 ms delay, and differs by 0.225 when the…

    Results, The circuit encodes a continuous error spectrum, paragraph 1; Figure 2Cdata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig2c-robust-to-input-delay
    From the paper

    The model was robust to exact time difference between prediction and sensory inputs and delaying either input by 5 ms resulted in the same behaviour ( Fig. 2C ).

    Result

    At L4 60 nS with prediction the expected count is 0.775 at 0 ms delay, and differs by 0.225 when the prediction is delayed 5 ms and 0.3125 when the sensory input is, both below 0.5. Seeds give differences 0.125 to 0.3125.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • The L4 conductance of the Figure 2B arrow is not given; the Methods' default 60 nS is used, as the criterion says.
  • Reproduced

    As sensory input weakens relative to the prediction, the latency of the breakthrough spike lengthens continuously.

    Over 31 L4 conductances (0 to 150 nS) where runs spike, the mean first-spike latency falls from 18.4 ms to…

    Results, The circuit encodes a continuous error spectrum, paragraph 1; Figure 2Dverifier disagreed at firstrests on an assumptiondata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig2d-latency-grows-as-sensation-weakens
    From the paper

    As sensation weakened relative to prediction, breakthrough latency lengthened ... the resulting L2/3 spike arrived progressively later relative to the bAP ( Fig. 2D )

    Result

    Over 31 L4 conductances (0 to 150 nS) where runs spike, the mean first-spike latency falls from 18.4 ms to 2.36 ms, Spearman rho -0.999. The largest 5 nS step, 3.25 ms between 35 and 40 nS, resampled at 1 nS with 4000 runs per conductance, changes latency by 3.03 ms in five steps of which the largest is 1.30 ms (0.43 of the change), and 0.40 of first spikes in that interval fall between 8 and 12 ms, between the release and breakthrough latencies. Seeds give rho -0.989 to -0.999 and a largest 1 nS share of 0.23 to 0.43. The coarse test against a quarter of the latency range fails under 3 of 5 seeds (steps of 5.25, 6.28 and 6.06 ms); the resampling shows these steps are sampling noise of the 80-run means.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • Assumption. "Without a single jump" is tested as continuity, a choice made here as the criterion gives no number. The interval of the largest 5 nS step is resampled at 1 nS with 4000 runs; a jump is one 1 nS step that carries more than half the latency change across that interval. The earlier test (largest 5 nS step below half the latency range) and a stricter one (below a quarter) are printed.
  • Reproduced

    At low somatic gain of L4 and L5 IT, strong sensory input rarely drives bursts and an omission (prediction only) often ends in silence instead of a gated release spike.

    High gain bursts from L4 115 nS (8 conductances up to 150 nS); at those, no Low-gain sensory run fires two…

    Results, Precision weighting of prediction error, paragraph 1; Figure 3Adata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig3a-low-gain-suppresses-errors
    From the paper

    At low gain, both error signals were effectively suppressed ... strong sensory inputs rarely drove bursts, and stimulus omission frequently ended in silence

    Result

    High gain bursts from L4 115 nS (8 conductances up to 150 nS); at those, no Low-gain sensory run fires two spikes (fraction 0.0, High 1.0), and all Low-gain prediction-only runs are silent (1.0; Mid 0.9875, High 0.075). All five seeds agree.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
  • Reproduced

    Raising L4 and L5 IT gain lowers the sensory threshold for bursts and raises the probability of a gated release spike on omission trials.

    Under reading (b) the burst threshold falls from 515 nS (Low) to 230 (Mid) to 115 (High).

    Results, Precision weighting of prediction error, paragraph 1; Figure 3A and 3Bverifier disagreed at firstdata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig3b-gain-lowers-burst-threshold
    From the paper

    As L4 and L5 IT gain increased the sensory threshold for bursts decreased (favouring LTP; Fig. 3A,B ), and the probability of a gated release spike on omission trials increased (favouring LTD; Fig. 3B ).

    Result

    Under reading (b) the burst threshold falls from 515 nS (Low) to 230 (Mid) to 115 (High). With 800 prediction-only runs per gain the omission spike probability is 0.0, 0.026 and 0.948, so it rises from Low to Mid to High; all five seeds meet the criterion (Mid 0.013 to 0.040, Low 0 of 800 in every seed). With 80 runs, as in the first run, Mid gave 0.0 under the claim's seed and the strict rise failed; 80 runs cannot resolve a probability near 0.03. Under reading (a) no Low-gain threshold is found up to 600 nS and Mid and High are 350 and 355 nS, so (a) fails. Changed from partially reproduced after verification.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • Thresholds are searched over L4 0 to 600 nS (a plotting choice) so that one is found at each gain.
    • The omission probability is estimated from 800 runs per gain (80 elsewhere), a precision choice: the Mid-gain probability is about 0.03.
  • Reproduced

    Reducing basket cell conductance relative to L4 drive lowers the threshold for L2/3 bursts.

    Burst threshold (mean count >= 2, 10 runs) 55, 65, 85 and 105 nS at basket scalings 0.6, 0.8, 1.0 and 1.2.

    Results, L4 excitatory drive / basket cell inhibitory balance, paragraph 1; Figure 4Adata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig4a-basket-reduction-lowers-burst-threshold
    From the paper

    Reducing basket cell conductance relative to L4 excitatory drive lowers the burst firing threshold ( Fig. 4A ).

    Result

    Burst threshold (mean count >= 2, 10 runs) 55, 65, 85 and 105 nS at basket scalings 0.6, 0.8, 1.0 and 1.2. All five seeds agree (1.2 gives 95 to 105 nS).

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
  • Reproduced

    Reducing ChC conductance shortens the latency of the first L2/3 spike for a given L4 strength and lowers the L4 needed for a positive error.

    L5 IT 12 nS, ChC 0 to 50 nS, L4 0 to 150 nS, 10 runs.

    Results, L5 IT excitatory drive / chandelier cell inhibitory balance, paragraph 1; Figure 4Brests on an assumptiondata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig4b-chc-reduction-shortens-latency
    From the paper

    Reducing chandelier cell conductance relative to L5 IT excitatory drive decreased L2/3 spike latency for a given L4 strength reducing the L4 threshold required for generating a positive error ( Fig. 4B ).

    Result

    L5 IT 12 nS, ChC 0 to 50 nS, L4 0 to 150 nS, 10 runs. At all 16 L4 conductances where every ChC level has spiking runs, latency rises with ChC (rho 0.46 to 0.99, median 0.95). The breakthrough threshold rises with ChC from 0 to 115 nS (rho 0.97). Taken literally, the lowest L4 > 0 with expected count >= 0.5 is 5 nS at every ChC level, because the release spike fires at weak L4, so that part of the criterion cannot fall; the outcome rests on reading it as the breakthrough threshold. All five seeds agree. Question for the authors in the findings.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • ChC 0 to 50 nS in steps of 5 is a plotting choice.
    • Assumption. The lowest L4 that drives a spike is taken as the breakthrough threshold, the lowest L4 above the conductance of least firing where the expected count reaches 0.5, after the paper's 'L4 threshold required for generating a positive error' (Results, L5 IT excitatory drive / chandelier cell inhibitory balance, paragraph 1). The plain reading is printed and cannot decide the claim.
  • Reproduced

    Without sensory input, raising L5 IT conductance with ChC fixed at 25 nS shortens the release spike latency, and strong L5 IT input can produce a doublet instead of a singlet.

    Without L4, median release latency falls from 17.1 ms at L5 IT 12 nS to 7.7 ms at 40 nS (rho -1.0), and the…

    Results, L5 IT excitatory drive / chandelier cell inhibitory balance, paragraph 1; Figure 4C and 4Ddata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig4cd-l5it-shortens-release-and-doublets
    From the paper

    In the absence of sensory input, release-spike latency shortened with rising predictive drive ( Fig. 4C ), and for strong L5 IT inputs could produce a doublet

    Result

    Without L4, median release latency falls from 17.1 ms at L5 IT 12 nS to 7.7 ms at 40 nS (rho -1.0), and the expected count reaches 2 at 22 nS. Seeds on a 12 to 120 nS grid give rho -0.9993 to -0.9996 and doublets from 24 nS.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
  • Reproduced

    With strong L5 IT drive, weak sensory inputs reach the burst threshold at a lower L4 conductance.

    ChC 25 nS; burst threshold 355, 360, 330, 0, 0 and 0 nS for L5 IT 12, 16, 20, 24, 28 and 32 nS (rho -0.88).

    Results, L5 IT excitatory drive / chandelier cell inhibitory balance, paragraph 1; Figure 4Ddata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig4d-strong-prediction-lowers-burst-threshold
    From the paper

    We also observed that weak sensory inputs interacting with strong L5 IT drive had a lower burst threshold ( Fig. 4D ).

    Result

    ChC 25 nS; burst threshold 355, 360, 330, 0, 0 and 0 nS for L5 IT 12, 16, 20, 24, 28 and 32 nS (rho -0.88). From 24 nS L5 IT alone gives doublets, so the threshold is 0. Seeds give rho -0.88 to -0.94. Most of the fall comes from L5 IT alone: from 12 to 20 nS the threshold is 310 to 360 nS, rises from 12 to 16 nS under 2 of the 5 seeds, and is lower at 20 than at 12 nS under all five (by 15 to 40 nS).

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • L5 IT 12 to 32 nS in steps of 4 and L4 up to 600 nS are plotting choices; the threshold at 12 nS lies above 150 nS.
  • Reproduced

    Raising the ChC conductance, or lowering the ChC reversal potential, can restore the release spike latency after an increase in L5 IT drive.

    Prediction only, 10 runs. Reference latency 18.2 ms; L5 IT 20 nS gives 11.65 ms; ChC 90 nS or E_ChC -74 mV…

    Results, L5 IT excitatory drive / chandelier cell inhibitory balance, paragraph 2; Figure 4E and 4Fdata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig4ef-compensation-restores-latency
    From the paper

    Either change restored the latency of the gated release spike after an increased L5 IT drive created an E/I imbalance.

    Result

    Prediction only, 10 runs. Reference latency 18.2 ms; L5 IT 20 nS gives 11.65 ms; ChC 90 nS or E_ChC -74 mV bring it back within 1 ms. At L5 IT 24 nS, ChC up to 100 nS does not, E_ChC -78 mV does. All five seeds meet the criterion at 20 nS (ChC 52.5 to 95 nS, E_ChC -65 to -75 mV). With 10 runs a median within 1 ms can occur by chance on a fine grid.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • ChC 25 to 100 nS and E_ChC -58 to -80 mV are plotting choices.
  • Reproduced

    The analysis includes 266 putative pyramidal image-responsive L2/3 cells from 78 recordings and 1075 such L5 cells from 98 recordings of mouse V1.

    The reader's answer named which sessions enter as open detail O9, so the criterion now runs every reading of…

    Figure 6B legend; Figure 7A legendquestion to the readeruses data from outside the datasetcell-counts
    From the paper

    n = 266 cells from n = 78 recordings; L5 ... n = 1075 cells from n = 98 recordings

    Result

    The reader's answer named which sessions enter as open detail O9, so the criterion now runs every reading of O1, O2, O3 and O9; before, it ran over all sessions only and was not reproduced. Under O9 (b), the 104 sessions of the Sst-Cre and Vip-Cre Ai32 mice, all 16 readings of O1 to O3 put the four counts within tolerance (245 to 270 L2/3 cells from 76 to 81 recordings; 996 to 1101 L5 cells from 100 recordings). Under O9 (a), all 153 sessions, none does (363 to 396 L2/3 cells from 113 to 116 recordings; 1424 to 1577 L5 cells from 143). The measured values are the first reading that matches (O1 a a, O2 a, O3 a, O9 b). Optotagging removes 16 to 17 L2/3 or L5 candidates in Sst-Cre and 7 to 8 in Vip-Cre mice (108 and 18 to 19 tagged VISp units in all), none in wild-type mice; O3 changes the total by 1. The match under O9 (b) comes from which sessions enter, not from the filter.

    Deviations from the paper’s method
    • Layer from the CCF annotation; 351 units without coordinates are left out.
    • The optotagging z-score baseline and the pulses used are open (O3); both readings are run and change counts by at most 1.
    • Which sessions enter is open (O9); both readings are run, and the claim matches under (b) only.
  • Reproduced

    In L2/3 and L5 neurons the fraction of spikes in bursts is highest for the first presentation of an image after a change and falls markedly from the first to the second repetition.

    Changed from partially reproduced after verification, which asked for the other cell selections.

    Results, LTP-favouring conditions, paragraph 1; Figure 5Cquestion to the readeruses data from outside the datasetfig5c-fsb-highest-on-first-repetition
    From the paper

    the fraction of L5 spikes occurring within bursts (FSB) was highest for the first stimulus presentation and decreased with repeated presentations ( Fig. 5B–C ). Similarly, L2/3 neurons had highest burst rate for the first stimulation ... For both L5 and L2/3, FSB decreased markedly from the first to second repetition.

    Reported statistics
    • L2/3 intercept, FSB difference from Repetition 1: mixed-effects model, random effect of session, t(1860) = -10.35, p < 10⁻²⁵, 95% CI -0.07 to -0.05
    • L5 intercept, FSB difference from Repetition 1: mixed-effects model, random effect of session, t(7523) = -22.3, p < 10⁻¹⁰⁹, 95% CI -0.055 to -0.046
    Result

    Changed from partially reproduced after verification, which asked for the other cell selections. The claim takes its cells from cell-counts, whose 16 readings of O1 to O3 all give the paper's counts under O9 (b), and the criterion asks for one reading. On the first selection (O1 a a, O2 a, O3 a) all 16 analysis readings give both intercepts negative with p below 1e-7 under both O9 readings; under O9 (b) none is within tolerance (closest misses by 0.0024; first reading L2/3 -0.0444, L5 -0.0448). Under O9 (b), on the selections O1 a b, O2 a, O3 a or b, one reading (O8 a, O4 a, square root, coding k) gives L2/3 -0.0524 and L5 -0.0548, inside by 0.0002 to 0.0003; the other 14 selections miss by 0.0001 to 0.0025. The measured values are this O9 (b) reading, as cell-counts matches the paper only under O9 (b). Under O9 (a) 8 of 16 selections have a reading within tolerance, inside by up to 0.0012 (first, O1 a a, O2 a, O3 a, O8 b, O4 a, linear, k - 2, L2/3 -0.0505, L5 -0.0473). 38 of 49 subjects (L2/3) and 49 of 53 (L5) have a mean drop under O9 (b). Under O9 (b) the outcome rests on one reading inside the tolerance by 0.0002 to 0.0003, and that reading codes repetition as k, which the claims file lists but which extrapolates the intercept to repetition 0; coding k against k - 2 moves the L5 intercept by about 0.0018 (-0.0574 against -0.0592, O9 b, O8 a, O4 a, square root), six times the margin. A question to a reader asks whether coding k fits the claim.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • The coding of repetition (k - 2 or k), O4, O6 and O8 are open; all 16 readings are shown on each cell selection.
  • Reproduced

    After the drop at the second repetition, L5 FSB keeps decreasing at a low rate with further repetitions.

    Unchanged by the answer; both O9 readings reproduce it.

    Results, LTP-favouring conditions, paragraph 1; Figure 5Cuses data from outside the datasetfig5c-l5-fsb-keeps-declining
    From the paper

    A linear mixed-effects model showed FSB decreased at a low rate with further repetitions in L5

    Reported statistics
    • L5 slope on repetition: mixed-effects model, random effect of session, t(7523) = 8.1, p < 10⁻¹⁵, 95% CI -0.0011 to -0.0007
    Result

    Unchanged by the answer; both O9 readings reproduce it. Under O9 (a) the L5 slope is -0.00089 per repetition, t(9973) = -2.91, p = 0.0037, CI -0.0015 to -0.0003 (first readings, the measured value); under O9 (b) it is -0.00099, t(6977) = -2.67, p = 0.0077, also within tolerance. With O4 b the slope is -0.00042 and -0.00051 (p 0.04 to 0.05), and 3 of 8 readings under O9 (a) and 4 of 8 under O9 (b) have p above 0.05. The printed t of the paper is positive; the sign here is negative, as its CI and text.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
  • Reproduced

    In L2/3, FSB does not change further with repetitions after the second.

    Unchanged by the answer. L2/3 slope -0.0004 per repetition, t(2560) = -0.56, p = 0.58, CI -0.0018 to 0.0010…

    Results, LTP-favouring conditions, paragraph 1; Figure 5Cuses data from outside the datasetfig5c-l23-fsb-stable
    From the paper

    A linear mixed-effects model showed FSB decreased at a low rate with further repetitions in L5, while it remained stable in L2/3 ( Fig 5C ).

    Reported statistics
    • L2/3 slope on repetition: mixed-effects model, random effect of session, t(1860) = -0.59, p = 0.55, 95% CI -0.001 to 0.004
    Result

    Unchanged by the answer. L2/3 slope -0.0004 per repetition, t(2560) = -0.56, p = 0.58, CI -0.0018 to 0.0010 under O9 (a); -0.0006, t(1727) = -0.70, p = 0.48 under O9 (b); over the 16 readings p is 0.39 to 0.93.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
  • Reproduced

    Firing rate falls at the second presentation, then recovers slightly to a stable level over further repetitions; neither L2/3 firing nor L5 bursting falls to zero.

    Unchanged by the answer. Under O9 (a), median modulation index against Repetition 1 at Repetition 2 -0.386…

    Results, LTP-favouring conditions, paragraph 1; Figure 5Duses data from outside the datasetfig5d-firing-rate-dips-then-stable
    From the paper

    The firing rate followed a distinct time course over the same repetitions ... it fell at the second presentation and then recovered slightly to a stable level ( Fig. 5D ). Neither L2/3 firing rate nor L5 bursting declined to zero.

    Result

    Unchanged by the answer. Under O9 (a), median modulation index against Repetition 1 at Repetition 2 -0.386 (L2/3) and -0.209 (L5); 3 to 8 from -0.18 to -0.25 and -0.10 to -0.13, all above Repetition 2. Mean L2/3 rate 3.5 to 7.5 Hz and mean L5 FSB 0.157 to 0.209 at every repetition. O8 b and O9 (b) meet the criterion as well (O9 b, O8 a, -0.394 and -0.207 at Repetition 2).

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
  • Reproduced

    L5 bursting is higher for presentations that follow an omission than for those that precede it.

    Unchanged by the answer. L5 FSB after omission minus before, 0.0072, t(1424) = 5.32, p = 1.2e-07 under O9 (a)…

    Results, LTP-favouring conditions, paragraph 2; Figure S1A to S1Cuses data from outside the datasetfigs1-post-omission-bursting
    From the paper

    The decrease in L5 bursting was reversed when a repeated presentation followed an unpredictably omitted stimulus. Post-omission stimuli drove significantly higher burst rates than pre-omission stimuli ( Fig. S1A–C )

    Result

    Unchanged by the answer. L5 FSB after omission minus before, 0.0072, t(1424) = 5.32, p = 1.2e-07 under O9 (a) (difference, O4 a), all six readings positive with p 2.7e-04 to 1.2e-07, 60 of 78 subjects; under O9 (b) 0.0059, t(996) = 3.41, p = 6.8e-04, all six positive with p 0.025 to 6.8e-04, 37 of 53 subjects. L2/3, a variant, goes the same way (p 0.0026 to 0.032 under O9 a, 0.017 to 0.32 under O9 b).

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • Figure S1 and its legend are not in the text; the test is read from the Methods as the claims file says.
  • Reproduced

    The first presentation of a newly introduced image drives more bursting than the first presentation of a familiar image.

    Unchanged by the answer. 75 novel sessions; under O9 (a) 66 with L5 cells (637 cells, about 80 novel and 83…

    Results, LTP-favouring conditions, paragraph 2; Figure S1D and S1Euses data from outside the datasetfigs1-novel-image-bursting
    From the paper

    Burst probability also scaled with stimulus novelty ... the first presentation of a newly introduced image drove higher burst rates than the first presentation of a familiar image ( Fig. S1D–E ).

    Result

    Unchanged by the answer. 75 novel sessions; under O9 (a) 66 with L5 cells (637 cells, about 80 novel and 83 familiar Repetition 1 presentations each), L5 FSB novel minus familiar 0.036, t(636) = 6.04, p = 2.6e-09, all six readings positive with p below 1.3e-04, 51 of 66 subjects; under O9 (b) 46 sessions and 453 cells, 0.033, t(452) = 5.35, p = 1.4e-07, all six with p below 0.005. L2/3, a variant, 207 cells, difference 0.015, p = 0.18 (O9 b, 141 cells, p = 0.96).

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • A novel session is one in which some presentations are marked is_image_novel; blocks are counted per image within the session (Methods, Allen Brain Observatory data analysis).
  • Reproduced

    Trial by trial, L5 population firing correlates with L2/3 population firing.

    Unchanged by the answer. 28 sessions have at least 10 putative pyramidal cells per layer, 21 of them under O9…

    Results, L5 bursts are decoupled from L2/3 spiking on a trial-by-trial basis, paragraph 1; Figure S2uses data from outside the datasetfigs2-l23-l5-activity-correlated
    From the paper

    While overall L5 activity correlated with L2/3 activity

    Result

    Unchanged by the answer. 28 sessions have at least 10 putative pyramidal cells per layer, 21 of them under O9 (b) (only 1 has 10 responsive cells per layer). With populations of responsive cells, Repetition 1, the L5 rate residual rises with the L2/3 residual (slope 0.119, t(6806) = 16.0 under O9 a; 0.106, t(5133) = 12.5 under O9 b) and per-session r has median 0.185, t(27) = 7.19 (O9 b 0.164, t(20) = 5.31); post-omission and all-pyramidal populations give the same, all p below 0.001.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • The session threshold counts putative pyramidal cells without the responsive test, as the Methods say; populations of responsive cells and of all putative pyramidal cells are both shown.
    • Reading (b) tests per-session r with a one-sample t test, which an intercept-only mixed model with one value per session reduces to.
  • Reproduced

    Running increases L2/3 and L5 FSB on the first repetition of an image.

    Unchanged by the answer. O7 250 ms, O4 a, difference: L2/3 0.071, t(274) = 4.55, and L5 0.052, t(1119) = 5.97…

    Results, Locomotion amplifies positive error and reduces negative-error drive, paragraph 1; Figure 7Aquestion to the readeruses data from outside the datasetfig7a-running-raises-first-repetition-bursting
    From the paper

    Running increased L2/3 and L5 burst rate on the first repetition of the image ( Fig. 7A )

    Reported statistics
    • L2/3: mixed-effects model, intercept, t(265) = 10.1, p < 10⁻²³, 95% CI 0.05 to 0.1 (n = 266 cells from 78 recordings)
    • L5: mixed-effects model, intercept, t(1074) = 9.7, p < 10⁻²¹, 95% CI 0.03 to 0.06 (n = 1075 cells from 98 recordings)
    Result

    Unchanged by the answer. O7 250 ms, O4 a, difference: L2/3 0.071, t(274) = 4.55, and L5 0.052, t(1119) = 5.97 under O9 (a), both within tolerance (the measured values); under O9 (b) 0.053, t(179) = 3.04, and 0.047, t(764) = 4.95, also within; 750 ms gives 0.062 and 0.055 (O9 b 0.059 and 0.058). O4 b differences are smaller (L5 0.015, p = 0.0054; O9 b 0.012, p = 0.10). 91 L2/3 and 305 L5 cells (O9 b 67 and 232) lack Repetition 1 presentations in one state and are left out, so n is 275 and 1120 (O9 b 180 and 765), not the paper's 266 and 1075. 51 of 67 subjects (L5) go this way under O9 (a), 33 of 45 under O9 (b). Under D7, 26 of the 104 O9 (b) sessions have no stationary Repetition 1 presentation (80% of active presentations are classed running), so the paper's degrees of freedom, which imply every cell, cannot be reached; a question to a reader asks about it. Over the 16 cell selections under O9 (b) this reading gives L2/3 0.049 to 0.059 and L5 0.047 to 0.049.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
  • Reproduced

    During omission, FSB does not differ between running and stationary conditions, in L2/3 or L5.

    Under O9 (b), the reading the answer added, no layer, window or O4 reading has p < 0.05 under either cell…

    Results, Locomotion amplifies positive error and reduces negative-error drive, paragraph 1; Figure 7Crests on an assumptionuses data from outside the datasetfig7c-running-leaves-omission-bursting
    From the paper

    During omission, the fraction of L5 spikes occurring within bursts (FSB) did not differ between running and stationary conditions ( Fig. 7C )

    Reported statistics
    • L2/3: linear mixed-effects model, intercept, t(46) = -1.0, p = 0.31, 95% CI -0.03 to 0.003 (n = 47 cells from 35 recordings)
    • L5: linear mixed-effects model, intercept, t(657) = 1.25, p = 0.21, 95% CI -0.0001 to 0.0016 (n = 658 cells from 94 recordings)
    Result

    Under O9 (b), the reading the answer added, no layer, window or O4 reading has p < 0.05 under either cell selection (selection b, 250 ms, O4 a, L2/3 -0.032, p = 0.13, L5 -0.0005, p = 0.91; lowest p 0.059), so the outcome no longer rests on the selection there; counts 143 L2/3 cells from 60 recordings and 778 L5 cells from 98 (selection b), against 47 from 35 and 658 from 94. Under O9 (a), as before, selection (b) is closer to the paper's counts (210 from 87 and 1108 from 138, the measured values, against 365 from 112 and 1407 from 141 under a) and gives no p < 0.05 (L2/3 -0.013, p = 0.41; L5 -0.0017, p = 0.66), while selection (a) gives L2/3 omission FSB higher when running with O4 a (0.034, p = 0.0048), which would not reproduce the claim. Question for the authors in the findings.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • Assumption. The criterion leaves the selection of the 47 and 658 cells open between (a) and (b) and says the counts inform which matches; (b) is adopted as the closer. Under O9 (b) both selections give the same outcome; under O9 (a) they differ. The paper's counts are smaller than either.

Partially reproduced4

  • Partially reproduced

    In the two-compartment model, L4 sensory input without L5 IT predictive input makes the L2/3 neuron fire a short-latency singlet or doublet, depending on L4 strength, immediately after the input arrives; basket cell inhibition ends the response.

    With L4 at 60 nS and no prediction all 80 runs spike, first spike a median 3.75 ms after L4 onset; half the…

    Results, Positive prediction error, paragraph 1; Figure 1Ddata in the paper's two-compartment LIF model, specified in full in the Methods (Brian 2); its code (github.com/bendor-lab/SETA-model_allen_analysis) was not public on 2026-11-21model-positive-error-short-latency
    From the paper

    When L4 sensory input arrives in the absence of L5 IT predictive input, the L2/3 neuron produces a singlet or doublet depending on the L4 input strength ... Because no ChC clamp is active, action potential initiation at the AIS is rapid and unimpeded. The resulting spike or burst occurs immediately following sensory input arrival

    Result

    With L4 at 60 nS and no prediction all 80 runs spike, first spike a median 3.75 ms after L4 onset; half the runs fire doublets from 90 nS and all from 115 nS. Under the claim's seed 1 of 81 spikes at 60 nS (0.012) falls after the basket conductance peak (8.5 ms after L4 onset), so the strict "no spike after the basket peak" fails; seeds plus 1000 to 4000 give latencies 3.7 to 3.8 ms and 0 or 0.012 late spikes (criterion met under 3 of 5). Over every L4 from 0 to 150 nS, 0.009 of first spikes and 0.046 of all spikes fall after the basket peak under the claim's seed: single spikes at weak L4 (15 to 30 nS, 18 spikes), second spikes of doublets (75 to 120 nS, 119 spikes) and 1 each at 60, 65 and 70 nS.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
    • The criterion's first few ms is read as before the basket conductance peak (8.5 ms), a choice made here.
  • Partially reproduced

    Firing rate during stimulus omission is lower than during spontaneous activity, in both L2/3 and L5.

    Changed from not reproduced after verification, with the spontaneous period now both blocks.

    Results, LTD-favouring conditions, paragraph 1; Figure 6Bverifier disagreed at firstrests on an assumptionquestion to the readeruses data from outside the datasetfig6b-omission-firing-below-spontaneous
    From the paper

    The omission firing rate was also lower than spontaneous in both L2/3 and L5

    Reported statistics
    • L2/3: linear mixed-effects model, intercept, t(265) = -10.4, p < 10⁻²⁴, 95% CI -0.23 to -0.11 (n = 266 cells from 78 recordings)
    • L5: linear mixed-effects model, intercept, t(1074) = -12.8, p < 10⁻³⁶, 95% CI -0.15 to -0.08 (n = 1075 cells from 98 recordings)
    Result

    Changed from not reproduced after verification, with the spontaneous period now both blocks. Against both blocks, all windows (O5 a), omission firing is lower in both layers: under O9 (b) L2/3 -0.221, t(246) = -6.04, p = 5.7e-09 (within tolerance) and L5 -0.228, t(996) = -14.1, p = 4.3e-41 (outside -0.15 to -0.08); under O9 (a) L2/3 -0.245 and L5 -0.251, p below 1e-15 (the measured values, both outside). Over all 16 cell selections and both O9 readings both layers are negative with p below 1e-8 and L5 is -0.227 to -0.274; without the low-AUC sessions L5 is -0.223. 49 of 53 (L5) and 37 of 49 (L2/3) subjects have a negative mean under O9 (b). With stationary windows only (O5 b) L2/3 is not significant (p = 0.32 and 0.45). Block 3 alone gives the same outcome; block 1 alone gives L5 -0.112 (p = 2.5e-08, O9 b) but L2/3 0.007 (p = 0.87), which would not reproduce the claim. Block 1 starts 18 to 29 s after the task in 152 of 153 sessions and block 3 about 940 s after it; mice run in 86% of block 1 windows and 84% of block 3 windows. Questions to a reader and to the authors in the questions file and the findings.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • Assumption. The files hold two spontaneous grey-screen blocks after the task, 10 s starting 18 to 29 s after it (block 1) and 289 s after the receptive-field mapping (block 3). Both are adopted: the Methods name one spontaneous period, 'the period of mouse inactivity immediately following the task', and the Results call it 'spontaneous activity outside the stimulus blocks' (Results, LTD-favouring conditions); both blocks are such periods and the files list both, and only these, in intervals/spontaneous_presentations; mice run in most windows of both, so 'inactivity' cannot mean stationary; block 1 alone gives 40 windows per cell and a median of 0 stationary windows, so O5 (b) cannot be applied to most cells. Under O5 (a), the adopted reading, block 1 leaves out only 4 L2/3 and 15 L5 cells under O9 (a) and 1 and 9 under O9 (b), so this does not argue against block 1 there. Both blocks give a median of 1155 block 3 windows per cell against 40 from block 1, so in effect they are block 3. The assumption is defensible but no better supported than block 1 alone, the literal reading of 'immediately following', which is shown and would not reproduce either fig6b or fig6c. The first run adopted block 1.
  • Partially reproduced

    L5 neurons show near-zero bursting during omission, with FSB below that of spontaneous activity.

    Changed from not reproduced after verification, with the spontaneous period now both blocks.

    Results, LTD-favouring conditions, paragraph 1; Figure 6C and 6Dverifier disagreed at firstrests on an assumptionuses data from outside the datasetfig6c-omission-bursting-below-spontaneous
    From the paper

    L5 neurons showed near-zero bursting during stimulus omission, significantly below spontaneous activity outside the stimulus blocks ( Fig. 6 )

    Reported statistics
    • mixed-effects model, intercept, t(1074) = -7.1, p < 10⁻¹¹, 95% CI -0.004 to -0.001 (n = 1075 cells from 98 recordings)
    Result

    Changed from not reproduced after verification, with the spontaneous period now both blocks. Against both blocks, O5 a, O4 a, difference, L5 omission FSB is below spontaneous: -0.0071, t(996) = -2.32, p = 0.020, CI -0.0130 to -0.0011 under O9 (b), and -0.0050, p = 0.021 under O9 (a) (the measured value), both outside the tolerance of -0.004 to -0.001. 7 of 12 readings against both blocks are negative with p < 0.05 under O9 (b) (5 under O9 a) and none is within tolerance. Over all 16 cell selections the first reading is -0.0050 to -0.0104 with p at most 0.021. Block 3 alone gives the same outcome; block 1 alone gives a positive difference (0.0073, p = 0.024 under O9 b) and no negative reading with p < 0.05. Mean L5 omission FSB is 0.041, not near zero.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • Assumption on the spontaneous period, as in fig6b-omission-firing-below-spontaneous.
  • Partially reproduced

    Running increases L2/3 and L5 firing rate on the first repetition of an image.

    Unchanged by the answer. Modulation index running against stationary at Repetition 1, L2/3 0.220 (t(274) =…

    Results, Locomotion amplifies positive error and reduces negative-error drive, paragraph 1; Figure 7Buses data from outside the datasetfig7b-running-raises-first-repetition-rate
    From the paper

    Running also increased L2/3 and L5 firing rate ( Fig. 7B ).

    Reported statistics
    • L2/3: linear mixed-effects model, intercept, t(265) = 7.3, p < 10⁻¹², 95% CI 0.09 to 0.29 (n = 266 cells from 78 recordings)
    • L5: linear mixed-effects model, intercept, t(1074) = 6.4, p < 10⁻⁹, 95% CI 0.05 to 0.16 (n = 1075 cells from 98 recordings)
    Result

    Unchanged by the answer. Modulation index running against stationary at Repetition 1, L2/3 0.220 (t(274) = 6.77, within tolerance), L5 0.186 (t(1119) = 10.2), above the L5 tolerance of 0.05 to 0.16, under O9 (a); under O9 (b) 0.183 (within) and 0.174 (above); 750 ms gives 0.221 and 0.191 (O9 b 0.215 and 0.198). Over all 16 cell selections and both O9 readings L5 is 0.170 to 0.199, above the tolerance under every one, and L2/3 0.181 to 0.253; without the low-AUC sessions L5 is 0.173.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • Cells without Repetition 1 presentations in both running states are left out (the modulation index needs both); see fig7a-running-raises-first-repetition-bursting.

Not reproduced5

  • Not reproduced

    When L4 input is weaker than the predictive input, the ChC clamp vetoes the L2/3 spike and basket cell inhibition prevents the gated release spike, so the neuron is silent.

    With L5 IT 12 nS, ChC 25 nS and L4 from 2 to 11.9 nS (basket 1.2 times L4, simultaneous onset), the expected…

    Results, The circuit encodes a continuous error spectrum, paragraph 1; Figure 2Aquestion to the readerdata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig2a-weak-sensory-silenced
    From the paper

    When L4 input was weaker than the predictive input, the ChC clamp successfully vetoed the L2/3 spike, and basket cell hyperpolarisation prevented the gated release spike ( Fig. 2A ), resulting in no spiking.

    Result

    With L5 IT 12 nS, ChC 25 nS and L4 from 2 to 11.9 nS (basket 1.2 times L4, simultaneous onset), the expected count is 0.90 to 0.975 per run, against 0.975 for the prediction alone; the five seeds give 0.89 to 0.99. The neuron is quietest near L4 40 nS (0.15 spikes per run), where L4 conductance exceeds L5 IT's, so the paper's "weaker than the predictive input" may compare the inputs on another scale. Without noise the failure is the same: a release spike fires at 18.7 ms for every L4 from 0 to 10 nS and none from 12 nS. At L4 10 nS the basket conductance (1.2 times L4) peaks at 12 nS and has fallen to 6.4 nS at 18 ms while L5 IT is still 7.7 nS and ChC 4.5 nS, so the AIS reaches threshold as the clamp decays. In this model the release spike is vetoed only when L4 is at least as strong as L5 IT in conductance; a question to a reader asks how the paper compares the two inputs.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
  • Not reproduced

    Gain does not substantially change the delay of the gated release spike when it occurs.

    Prediction only at gains 0.2, 0.5 and 1.0.

    Results, Precision weighting of prediction error, paragraph 1; Figure 3Cdata in the paper's two-compartment LIF model, specified in the Methods; code not public on 2026-11-21fig3c-gain-keeps-release-delay
    From the paper

    Critically, increased gain did not substantially alter the delay of the gated release spike when it occurred ( Fig. 3C ).

    Result

    Prediction only at gains 0.2, 0.5 and 1.0. No run spikes at Low gain, 1 of 80 at Mid (latency 24.0 ms) and 76 at High (median 17.35 ms), so a release delay exists at two gains, 6.65 ms apart, above the 5 ms the criterion allows. Seeds give 1 to 4 spiking Mid runs at 22.1 to 34.8 ms against 17.35 to 18.2 ms at High. The paper's "when it occurred" may refer to a regime where release spikes occur at every gain, which the Methods' parameters do not give. With 800 runs per gain, Low gain has no spiking run in any seed, Mid 18 to 24 runs at a median 22.6 to 26.2 ms and High 17.6 to 17.9 ms, 5.0 to 8.3 ms apart.

    Deviations from the paper’s method
    • The model is integrated in NumPy with the Euler-Maruyama method at dt 0.1 ms from the Methods' equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics), not in Brian 2, as the paper's code was not public; 50 ms of rest before the inputs and a 100 ms counting window are standard choices.
  • Not reproduced

    Firing rates do not differ between the first presentations of novel and familiar images.

    Under O9 (b) the L5 modulation index of rate, novel against familiar, is -0.043, t(452) = -2.61, p = 0.0095…

    Results, LTP-favouring conditions, paragraph 2; Figure S1Fuses data from outside the datasetfigs1-novel-firing-rate-unchanged
    From the paper

    Because firing rates did not differ between novel and familiar presentations ( Fig. S1F )

    Result

    Under O9 (b) the L5 modulation index of rate, novel against familiar, is -0.043, t(452) = -2.61, p = 0.0095, CI -0.075 to -0.010, so the paper's test finds a difference; 30 of 46 subjects have a negative mean. Under O9 (a) it is -0.035, t(636) = -2.44, p = 0.015, CI -0.064 to -0.007. The first run gave p = 0.059 under O9 (a) from a fit that had not converged; refitted with Powell's method it converges. Over all 16 cell selections and both O9 readings the index is -0.035 to -0.068 with p 0.00027 to 0.017, so the outcome no longer rests on O9. L2/3, a variant, shows none (0.019, p = 0.41; O9 b -0.002, p = 0.94).

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • Mixed models that do not converge with L-BFGS are refitted with Powell's method, then Nelder-Mead, then BFGS (vbn.mixed), a standard choice.
  • Not reproduced

    Trial by trial, L5 burst fraction is not predicted by L2/3 or L5 population firing rate, for the first repetition and for post-omission presentations.

    Unchanged by the answer. The L5 rate residual predicts the L5 FSB residual in every case under both O9…

    Results, L5 bursts are decoupled from L2/3 spiking on a trial-by-trial basis, paragraph 1; Figure S2A and S2Buses data from outside the datasetfigs2-l5-bursting-not-predicted-by-rate
    From the paper

    L5 burst rate was not predicted by either L2/3 or L5 firing rate. This held for both first repetition ( Fig. S2A ) and post-omission conditions ( Fig. S2B ).

    Result

    Unchanged by the answer. The L5 rate residual predicts the L5 FSB residual in every case under both O9 readings (responsive cells, Repetition 1, slope 0.0103, t(6788) = 26.7, p = 9e-150 under O9 a; t(5116) = 23.1 under O9 b). The L2/3 rate residual predicts it for Repetition 1 (p = 1.5e-05; O9 b 6.3e-05) but not for responsive cells after omissions (p 0.38 to 1.0). 14 of 16 cases under O9 (a) and 13 of 16 under O9 (b) have p < 0.05. FSB on a trial with one or two spikes is bounded by the spike count, which ties it to rate.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
  • Not reproduced

    During omission, firing rate is lower when running than when stationary, in L2/3 and L5.

    Unchanged by the answer. Under selection (b), L2/3 omission rate is lower when running (-0.146, t(209) =…

    Results, Locomotion amplifies positive error and reduces negative-error drive, paragraph 1; Figure 7Duses data from outside the datasetfig7d-running-lowers-omission-rate
    From the paper

    in spite of a reduction in firing rates during running in both L2/3 and L5 ( Fig. 7D )

    Reported statistics
    • L2/3: linear mixed-effects model, intercept, t(46) = -3.1, p = 0.002, 95% CI -0.45 to -0.1 (n = 47 cells from 35 recordings)
    • L5: linear mixed-effects model, intercept, t(657) = -4.3, p < 10⁻⁴, 95% CI -0.16 to -0.06 (n = 658 cells from 94 recordings)
    Result

    Unchanged by the answer. Under selection (b), L2/3 omission rate is lower when running (-0.146, t(209) = -3.80, p = 0.0002 under O9 a; -0.156, p = 0.0006 under O9 b; within tolerance) but L5 is not (-0.019, p = 0.29; O9 b -0.003, p = 0.88); 750 ms gives -0.174 and -0.032 (p = 0.12). Under selection (a) both indices are positive (L2/3 0.252, L5 0.148; O9 b 0.229 and 0.144), as 272 of 1407 L5 cells (O9 b 187 of 982) have no omission spikes in one state.

    Deviations from the paper’s method
    • Cells of cell-counts under its first-listed readings (O1 a a, O2 a, O3 a), under both readings of O9, all 153 sessions (a) and the 104 sessions of the Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32 mice (b). The deciding test is also run on all 16 readings of O1 to O3 under both O9 readings, and without the 10 sessions whose clock check gave an AUC below 0.8.
    • Cells as in fig7c-running-leaves-omission-bursting, selection (b).

Notes on the paper

What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.

  • Methods not availableThe Methods do not say which sessions enter the analysis. Over all 153 sessions the selection gives about 35% more cells and 45% more recordings than the paper's 266 L2/3 cells from 78 recordings and 1075 L5 cells from 98; over the 104 sessions of the Sst-Cre and Vip-Cre Ai32 mice, whose units can be optotagged, every reading matches. No outcome here depends on the choice, but the counts do. Did the analysis use only those sessions?#
  • Methods not availableThe Methods take spontaneous activity from 'the period of mouse inactivity immediately following the task'. The dataset has a 10 s grey screen starting 18 to 29 s after the task and a 289 s spontaneous block about 940 s after it, and the mice run in most windows of both. Against the 10 s block alone L2/3 omission firing does not differ from spontaneous and L5 omission FSB is higher; against the 289 s block, or both, both are lower. Both blocks are adopted here. Which block, and which windows within it (all, or stationary only), did Figure 6 use?#
  • Methods not availableHow FSB is formed for a cell (spikes in bursts summed over windows, or a mean of per-window fractions), whether burst spikes must fall within the 250 ms window, and how cells without spikes in a condition are treated are not stated; the readings change the Figure 5C intercepts by a factor of about 1.7 and decide whether Figure 7A's L5 effect is significant. Which was used?#
  • Methods not availableThe selection of the 47 L2/3 and 658 L5 cells of Figures 7C and 7D is not stated. Requiring omission windows in both running states gives 365 and 1407 cells; requiring an omission spike in each state gives 210 and 1108. Under the first, L2/3 omission FSB is higher when running (p = 0.005) and both omission rate indices are positive. What rule gave 47 and 658 cells?#
  • Methods not availableThe model's code is not public, and the Methods do not give the L4 and L5 IT onsets relative to each other in Figures 2A and 2B, the conductance ranges of Figures 2 to 4, or the threshold that defines a burst or a positive error. With simultaneous onsets and the Methods' parameters, L4 below 12 nS with the prediction does not silence the neuron (0.9 spikes per run; without noise a release spike at 18.7 ms for L4 up to 10 nS and none from 12 nS, as basket inhibition at 1.2 times L4 outlasts L5 IT drive only from there), and at Low gain release spikes never occur (0 of 800 runs), so Figure 2A and 3C are not reproduced. Which onsets and ranges were used, and how is 'weaker than the predictive input' measured?#
  • Paper inconsistentThe Figure 5C legend prints the L5 slope as t(7523) = 8.1 with CI [-0.0011, -0.0007], a positive t with a negative interval, and the L2/3 slope as t(1860) = -0.59 with CI [-0.001, 0.004], whose centre is positive. The data here give a negative L5 slope (t = -2.91), as the Results and the CI have it.#
  • OtherThe text of the preprint has a heading for Supplemental Figures with nothing under it, so the legends of Figures S1 and S2, which hold the tests of four findings, could not be read.#
  • Methods not availableThe degrees of freedom of Figure 7A and 7B, t(265) and t(1074), imply that all 266 L2/3 and 1075 L5 cells have Repetition 1 presentations both running and stationary. With the Methods' locomotion rule, 80% of active presentations are running and 26 of the 104 sessions of the Sst-Cre and Vip-Cre Ai32 mice have no stationary Repetition 1 presentation, so 67 L2/3 and 232 L5 cells cannot enter. How were running and stationary presentations defined for Figure 7, and how were cells without one of them treated?#

Questions about the claims 5

Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.

  • answered 2026-11-21asked about cell-counts

    The criterion selects units over "all sessions". Do the Methods instead restrict the analysis to the sessions of the optotagged mice (Sst-IRES-Cre;Ai32 and VIP-IRES-Cre;Ai32), so that putative Vip and Sst cells could be removed? The dataset holds 153 sessions, of which 104 are from such mice and 49 from wild-type mice without optotagging.

    Passage. Methods, Identification of pyramidal neurons, "The candidate cells were further filtered by removing putative inhibitory neurons identified in the optotagging data. The optotagging experiment used VIP-IRES-Cre;Ai32 or Sst-IRES-Cre;Ai32 transgenic mouse lines to identify Vip and Sst cells, respectively."

    Why it matters. Over all 153 sessions every reading of O1 to O3 gives 363 to 396 L2/3 cells from 113 to 116 recordings and 1424 to 1577 L5 cells from 143 recordings, outside every tolerance. Over the 104 sessions of optotagged mice every reading puts all four counts within tolerance (for example 247 L2/3 cells from 76 recordings and 997 L5 cells from 100 recordings). The claim is not reproduced as written and would be reproduced under this reading; the dependent claims are run on all sessions, with the optotagged sessions shown as a variant.

    The reader’s answer. Changed. The criterion attributed "all sessions" to the Methods, which do not say which sessions enter. They filter candidates "by removing putative inhibitory neurons identified in the optotagging data" and say the optotagging "used VIP-IRES-Cre;Ai32 or Sst-IRES-Cre;Ai32 transgenic mouse lines", which allows reading the analysis as limited to those mice. The header now names this as open detail O9, with readings (a) all sessions and (b) only the sessions of the two Cre;Ai32 lines, and the cell-counts criterion runs every reading of O1, O2, O3 and O9. The claims that take their cells from cell-counts inherit these readings. The statement and expected values are unchanged, and the change rests on the text, not on the counts reported in the question.
  • Detail O5 speaks of "the spontaneous block that follows the active task", as if there were one. The dataset has two grey-screen spontaneous blocks after the task, 10 s starting 18 to 29 s after it (block 1) and 289 s about 940 s after it, after the receptive-field mapping (block 3). Does the paper's spontaneous period mean block 1, block 3, or both, and should O5 name these as readings? The same applies to fig6c-omission-bursting-below-spontaneous.

    Passage. Methods, Allen Brain Observatory data analysis, "the period of mouse inactivity immediately following the task, to assess spontaneous neuronal activity"; Results, LTD-favouring conditions, "significantly below spontaneous activity outside the stimulus blocks ( Fig. 6 )".

    Why it matters. Against block 1 alone L2/3 omission firing does not differ from spontaneous (0.007, p = 0.87) and L5 omission FSB is higher (0.0073, p = 0.024), so neither claim is reproduced; against block 3 or both blocks both are lower and both claims are partially reproduced. The attempt adopts both blocks.

    No reader has answered it yet.
  • The criterion takes the cells of cell-counts and compares Repetition 1 presentations classed running and stationary by D7, but the paper's degrees of freedom (t(265), t(1074)) imply that every one of the 266 and 1075 cells has both. Should the criterion say how cells without stationary Repetition 1 presentations are treated, or whether the running state is defined otherwise for Figure 7? The same applies to fig7b-running-raises-first-repetition-rate.

    Passage. Figure 7 legend, "Mixed-effects model for L2/3 t (265) = 10.1, p < 10 -23 , CI = [0.05, 0.10], n = 266 cells from n = 78 recordings"; Methods, Locomotion detection.

    Why it matters. Under D7, 80% of active presentations are running and 26 of the 104 sessions of the Sst-Cre and Vip-Cre Ai32 mice have no stationary Repetition 1 presentation, so 67 L2/3 and 232 L5 cells are left out. A rule that keeps them would change the values compared with the tolerance; fig7b is partially reproduced because L5 is above its tolerance.

    No reader has answered it yet.
  • The criterion reads "L4 input weaker than the predictive input" as an L4 conductance below the L5 IT conductance (12 nS). The two inputs have different time constants (4 and 8 ms), and in the model the basket input that ends the release spike is 1.2 times L4. Does the paper compare the inputs by peak conductance, or by another measure such as their charge or effect at the soma?

    Passage. Results, The circuit encodes a continuous error spectrum, paragraph 1, "When L4 input was weaker than the predictive input, the ChC clamp successfully vetoed the L2/3 spike, and basket cell hyperpolarisation prevented the gated release spike ( Fig. 2A ), resulting in no spiking"; Methods, Synaptic connectivity and kinetics.

    Why it matters. With the Methods' parameters and no noise the neuron fires a release spike for every L4 up to 10 nS and is silent from 12 nS, the opposite of the claim under the peak-conductance reading; with noise the expected count below 12 nS is 0.89 to 0.99 against 0.1 required. Another measure of strength would change which L4 values the criterion tests.

    No reader has answered it yet.
  • The criterion lists two codings of repetition in the mixed model, (a) k - 2, so the intercept is the change at Repetition 2, and (b) k as is. Under (b) the intercept is the model's value at repetition 0, an extrapolation, and not the drop from Repetition 1 to Repetition 2 that the claim states. Does the paper's intercept fit coding (b), or should the criterion use only a coding whose intercept is the change at Repetition 2?

    Passage. Results, LTP-favouring conditions, paragraph 1, "For both L5 and L2/3, FSB decreased markedly from the first to second repetition"; Figure 5C legend, "Mixed-effects model on difference from Repetition 1, for L2/3 intercept, t(1860) = -10.35".

    Why it matters. Raised by the verifier in round 2. Under O9 (b), the only session reading that gives the paper's cell counts, the claim is reproduced on 2 of 16 cell selections and only under coding (b) (L2/3 -0.0524, L5 -0.0548), inside the L5 tolerance by 0.0002 to 0.0003; coding k against k - 2 moves the L5 intercept by about 0.0018. Without coding (b) no reading under O9 (b) is within tolerance; under O9 (a), whose cell counts are about 35% above the paper's, readings with coding (a) are.

    No reader has answered it yet.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Chandelier-cell temporal gating and L5 bursting in mouse V1 (Jarzebowski & Bendor 2026)

Tests the findings of Jarzebowski and Bendor (2026) on dandiset 000713, the Allen Institute's Visual Behavior Neuropixels recordings, which the paper reuses. It simulates the paper's two-compartment model of an L2/3 neuron from its Methods, and on the recordings selects putative pyramidal, image-responsive L2/3 and L5 units of VISp (layer from the CCFv3 annotation) and tests how their bursting and firing change with image repetition, omission, novelty and running. All files

Environment: Python 3.13, 20 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Reproduction Reward coding across mouse visual cortical areas (Souza et al. 2026)

Tests the findings of Souza et al. (2026) on dandiset 000713, the Allen Visual Behavior Neuropixels dataset, which the paper reuses. It rebuilds the reward-modulated cohort of units in six visual areas (split-half test against an ISI-shuffle null, then two cross-condition contrasts), its composition by area and waveform class, the reward modulation index, the population variability of the cohort, the decomposition of peri-reward profiles into archetypes, and the behavioural numbers the paper reports. The layer analyses use the CCFv3 annotation volume as an outside input. All files

Environment: Python 3.13, 50 packages pinned with their hashes in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-11-21
    Agreed with 27 of 31 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 1. The executed notebook of the run after the reader's answer (commit c69951d) with the conclusion cells and the summary removed, the helper modules vbn.py and seta_model.py and the claims file, with the paper's text. The verifier checked the version through the DANDI API, tested the helpers on synthetic inputs (_counts, fsb, mod_index, run_state, alpha) and ran the model module with noise switched off. It had no attempt record.
    • fig2d-latency-grows-as-sensation-weakens: the verifier’s outcome was “Partially reproduced”. Rho is -0.989 to -0.999, but the no-jump test uses the author's own threshold of half the latency range, which is lenient; the largest step is 2.8 to 6.3 ms of a 16 ms range, at the switch from release to breakthrough spikes (35 to 40 nS), and a quarter of the range would fail 3 of 5 seeds (problem 4).
    • fig3b-gain-lowers-burst-threshold: the verifier’s outcome was “Reproduced”. Under reading (b) the burst threshold falls from 515 to 565, to 215 to 230, to 110 to 115 nS in all seeds, and omission spike probability is 0, then 0 to 0.075, then about 0.94. The strict rise from Low to Mid fails in 2 seeds because both are 0, but pooled over the 5 seeds it is 0/400 against 12/400; the per-seed tests rest on very few spiking runs (problem 9).
    • fig6b-omission-firing-below-spontaneous: the verifier’s outcome was “Partially reproduced”. Using spontaneous block 3 or both blocks with O5 a, both layers are negative with p < 1e-8 but outside tolerance; with block 1, the reading the notebook adopts, L2/3 is not significant (p = 0.75 or 0.87). Block 1 (10 s, 40 windows, median 0 stationary windows) is adopted as the period immediately following the task, but block 1 starts 17.95 to 3276.62 s after the task and this was never investigated, and the Results' "spontaneous activity outside the stimulus blocks" allows block 3 (problem 2). O5 assumes a single block (problem 12).
    • fig6c-omission-bursting-below-spontaneous: the verifier’s outcome was “Partially reproduced”. With block 3 or both blocks, O5 a, the difference measure gives -0.0053 to -0.0071 (p of 0.02 to 0.03), outside the -0.004 to -0.001 tolerance; with block 1 the sign reverses (+0.007 to +0.008, p < 0.03). The block choice flips the sign (problem 2).
  • Round 2
    2026-11-21
    Agreed with 31 of 31 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: Round 2. The full executed notebook of the revision after round 1 (as at commit a7d55e8), the helper modules, the claims file, the attempt record and the paper's text. The verifier agreed with all 31 outcomes. No finding is rated critical, so none was reviewed as one; it agreed with the ratings of all four findings (three minor, one none) and found that the weak clock checks in 10 sessions are not established as errors. In its section on text it also found that the README's six minutes for the claims on all 16 selections should be about four (230 s), and that cell 0's statement that the draft has the same asset count and size is shown by no output. Both are corrected: the README now says four, and the statement is removed. Still unavailable, it noted, are the paper's model code and the legends of Figures S1 and S2.

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

Provenance

Attempt record
jarzebowski-2026-01
Paper
10.64898/2026.06.26.734797
Date
2026-11-21
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:000713 (on DANDI)
Version
0.240702.1725 (doi:10.48324/dandi.000713/0.240702.1725)
Check that the dataset is the paper’s data
Reproduced The layer of each unit, taken from the Allen CCFv3 annotation volume, can be matched to the dataset's units through the CCF coordinates of their peak channels, and agrees with the dataset's own area label.
Of 8348 D1 units labelled VISp, 7997 have coordinates and 7996 of them (0.9999) fall in a VISp layer voxel of the CCFv3 2017 10 um annotation (one in id 484682512). 351 units in 7 sessions have coordinates (0, 0, 0) and get no layer. The annotation file is checked by its SHA-256.
Run on
GitHub Actions
Harness
Claude Code
Model
claude-opus-5-5
Protocol
pilot-18

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Other data and code used 2

What the attempt used that is not in the dataset: other data, and the paper’s code. Each is as the attempt’s record describes it.

  • 10.1016/j.cell.2020.04.007 DOI

    Allen Mouse Brain CCFv3 2017 annotation volume at 10 um (annotation_10.nrrd), for the layer of each unit (Methods, Laminar classification). It has no DOI or versioned repository; the notebook checks the file's SHA-256, a9e9654ef491f0af107dc0a61bd720dabe7f36e8f3e9239532bf3dbdc94ef24c, as fetched on 2026-11-21. The annotation is described by Wang et al. (2020).

    Source as recorded: http://download.alleninstitute.org/informatics-archive/current-release/mouse_ccf/annotation/ccf_2017/annotation_10.nrrd (sha256 a9e9654ef491f0af107dc0a61bd720dabe7f36e8f3e9239532bf3dbdc94ef24c); doi:10.1016/j.cell.2020.04.007

  • The paper’s supplementary files

    The two-compartment model's equations and parameters (Methods, Computational model of L2/3 neuron; Synaptic connectivity and kinetics; Scaling of L2/3 inputs), simulated for the model claims.

    Source as recorded: doi:10.64898/2026.06.26.734797

Badges for this paper

Encore: 21 findings reproduced, Jarzebowski et al. 2026

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/jarzebowski-2026/"><img src="https://encorescience.org/badge/papers/jarzebowski-2026.svg" alt="Encore: 21 findings reproduced, Jarzebowski et al. 2026"></a>

Or as Markdown:

[![Encore: 21 findings reproduced, Jarzebowski et al. 2026](https://encorescience.org/badge/papers/jarzebowski-2026.svg)](https://encorescience.org/papers/jarzebowski-2026/)