Datasets
Not attempted yet. These are the claims read from the paper, which an attempt will test; next in the pipeline: attempt.
Claims 20
From the paper Resection of high frequency oscillations predicts seizure outcome in the individual patient · claims file · checked 2026-11-09: ready
The study included 20 patients, 9 with mesial temporal lobe epilepsy and 11 with extratemporal epilepsy; 13 became seizure free (ILAE 1) and 7 had recurrent seizures, a seizure-free rate of 65%.
From the paper
We included 20 patients (Table 1 ) of whom 9 with mesial temporal lobe epilepsy (TLE) and 11 with extratemporal epilepsy (ETE). Complete seizure freedom (ILAE 1 - International League Against Epilepsy, class 1) was reached in 13 patients, while 7 patients suffered from recurrent seizures (seizure-free rate = 65%)
Criterion
Counts of patients are exact (tolerance 0, as they are counts of whole patients). The epilepsy type and ILAE class of each patient are compared with Table 1. Reproduced when the deposit holds 20 patients and the counts match; the per-patient comparison is reported.
The number of recorded nights and of 5-minute intervals varies across patients as listed in Table 1 (from 1 night and 1 interval in patients 7 and 17 to 6 nights in patient 4 and 39 intervals in patient 3).
From the paper
The amount of nights and intervals varied across patients (Table 1 ).
Criterion
For each patient the count of distinct nights and of 5-minute intervals in the deposit is compared with Table 1 (Nights; Intervals). Reproduced when all 20 patients match on both; partially reproduced when at least 16 match on both; not reproduced otherwise. Every mismatch is listed. Table 1 itself does not respect the Methods' cap of six intervals per night for seven patients (see the opening comment); the comparison is with Table 1 as printed, and the largest number of intervals per night in the deposit is reported.
Detected ripples had median amplitude 27.4 microvolt peak-to-peak (interquartile range 15.0) and FR median amplitude 9.2 microvolt peak-to-peak (interquartile range 7.5).
From the paper
Automatic HFO detection yielded ripples (median amplitude 27.4 µVpp (peak-to-peak), interquartile range 15.0 µVpp) and FR (median amplitude 9.2 µVpp, interquartile range 7.5 µVpp)
Criterion
Events are the deposit's R and FR markings on the bipolar channels (Methods, Data acquisition, bipolar montage). The paper does not say on which signal the amplitude is taken or how events are pooled. Readings of the signal; (a) the band-passed signal of the event's band, with the detector's filters (Methods; ripples 80-240 Hz, FR 250-490 Hz, FIR equiripple, applied with filtfilt as in func_prepareMorphologyDetector.m, coefficients Filter_AsBurnos2016.mat of the linked repository), amplitude = maximum minus minimum within the event; (b) the same on the unfiltered bipolar signal. Readings of the pooling; (i) all events of all patients pooled; (ii) only events on channels not excluded (Table S1 gray). Reproduced when, under one reading, all four values are within tolerance; partially reproduced when the two medians are.
Mean follow-up was 29 +- 15 months for patients with poor outcome and 23 +- 11 months for good outcome, and the two distributions did not differ (Wilcoxon rank sum test, p = 0.25).
From the paper
The mean follow-up for poor outcome (29 ± 15 mo) was longer than for good outcome (23 ± 11 mo) but the two distributions are indistinguishable (Wilcoxon rank sum test, p = 0.25)
Criterion
A claim of absence, judged on the paper's test, a Wilcoxon rank sum test of follow-up months between ILAE 1 and ILAE 2-6 patients at p < 0.05 (Methods, Clinical validation). Follow-up months come from the deposit when it holds them, else from Table 1. The paper does not say whether the exact or the normal approximation was used; the approximation with continuity correction (Matlab ranksum's default for these sizes) is the main reading and the exact test a variant; on the follow-up months of Table 1 both give p = 0.25 (0.250 and 0.248). SD is the sample SD (n - 1). Reproduced when p >= 0.05 and the means and SDs are within tolerance; the p-value is reported.
The per-channel rates of ripples, FR and FRandR (events/min) of every patient are those listed in Table S1, and the channels marked there as the HFO area of each type are those whose rate exceeds the 95th percentile.
From the paper
The rates of ripple, FR and FRandR events are given in events/minute for each channel. Channels with the HFO rate exceeding the 95% percentile of the HFO distribution define the HFO area and are highlighted in green.
Criterion
Rates per channel from the deposit's R, FR and FRandR markings, under readings (a), (b) and (c) of the pooling over intervals named in the opening comment. Channels are matched by their bipolar label. A channel's rate matches when it is within 10% of the Table S1 value or within 0.1 events/min (the table's rounding), whichever is larger. Reproduced when, under one reading, at least 95% of the channel and type values of all 20 patients match; partially reproduced at 80% or more. The HFO area per patient and type is then computed as in the opening comment and compared with the green cells of Table S1; the count of patient and type areas that agree exactly is reported. The reading that matches best is used for the HFO area in the dependent claims.
In patient 4 (right hippocampal sclerosis, seizure free) the HFO types differ in their distribution over channels; several channels have FRandR rate 0; the ripple area was not resected, and the FRandR area, channel AR1-AR2, was resected.
From the paper
Note that several channels have FRandR rate = 0. ... The ripple area was not resected ( E ). The resection of the FRandR area ( G , channel AR1-AR2) led to seizure freedom.
Criterion
Patient 4's channel rates and HFO areas as in table-s1-rates, on the mesial temporal channels the figure shows (the channels not grayed in Table S1). Reproduced when the FRandR area is AR1-2 alone and resected, the ripple area contains at least one channel outside the RA (Table S1 red), and at least two channels have FRandR rate 0.0 at the precision of Table S1.
The FRandR area was fully inside the resected area in all 13 seizure-free patients and in 3 of the 7 patients with recurrent seizures (7, 8, 9), and not fully resected in 4 patients with recurrent seizures (17, 18, 19, 20).
From the paper
Among the 7 patients with recurrent seizures, FRandR were fully resected in 3 FN and not fully resected in 4 TP
Criterion
FRandR area per patient as in the opening comment, resected channels from Table S1 (red) unless the deposit marks them. A patient's area is fully resected when every area channel is resected. The per-patient result is compared with Table 1 (FRandR area resected? Y for 1-16, N for 17-20). Reproduced when all 20 patients agree; partially reproduced when the counts are off by one patient. Readings of the pooling and of the channel set as in the opening comment; the outcome is the one they all give, or as stated there.
The ripple and FR areas were resected in the patients marked in Table 1 (ripple area resected in 7 of 13 seizure-free and 4 of 7 recurrent-seizure patients; FR area in 9 of 13 and 5 of 7).
From the paper
No quote recorded.
Criterion
As frandr-area-resection-per-patient, for ripples and FR. Reproduced when at least 19 of 20 patients agree with Table 1 for each type and the counts match; partially reproduced when at least 17 of 20 agree for each.
Defining the HFO area by FRandR, its resection predicted seizure outcome with specificity 100% (CI 78-100%), sensitivity 57% (CI 18-90%), NPV 81% (CI 54-96%), PPV 100%, and accuracy 85% (CI 62-97%, p = 0.002, chi2 test).
From the paper
When defining the HFO area by FRandR (FRandR area, Fig. 1 ), we achieved specificity 100%, CI [78–100%] ... The low sensitivity (57%, CI [18–90%]) ... Analogous considerations hold for the NPV (81%, CI [54–96%]) ... Therefore, the overall accuracy of our algorithm (85%, CI [62–97%], p = 0.002 chi2-test)
Criterion
Counts TP, FP, FN, TN from frandr-area-resection-per-patient and the definitions of Methods, Clinical validation; percentages rounded to whole numbers must equal the paper's (tolerance 0, as each is a ratio of small whole counts and any change of one patient moves it by more than 4 points). CIs by the Clopper-Pearson binomial method, which gives every printed interval except the specificity lower bound (75.3, which the Discussion prints as 75); the asymptotic (Wald) method the Methods name for n > 10 is shown as a variant. The chi2 test is on the 2 x 2 table of area resection (fully, not fully) by outcome (ILAE 1, ILAE 2-6); the paper does not say which variant; readings (a) Pearson without continuity correction (gives p = 0.0023 on the paper's counts), (b) with Yates correction (p = 0.014), (c) Fisher's exact test (p = 0.0072). Reproduced when the five percentages match and p < 0.05 under reading (a).
With the area defined by ripples, specificity was 54%, sensitivity 43%, NPV 64%, PPV 33% and accuracy 50%; by FR, 69%, 29%, 64%, 33% and 55%.
From the paper
No quote recorded.
Criterion
As table2-frandr-prediction, for ripples and FR, without CIs or test. Tolerance 0 on percentages rounded to whole numbers, for the reason given there. Reproduced when all ten values match.
The FRandR area was more specific in predicting seizure freedom than the ripple and FR areas separately (specificity 100% against 54% and 69%).
From the paper
Defining the HFO area by FR co-occurring with ripples was more specific in predicting seizure freedom than FR and ripples separately.
Criterion
The paper reports no test of the difference. Reproduced when the FRandR specificity exceeds both the ripple and the FR specificity computed in the claims it depends on.
Taking Engel class I (ILAE 1-3) as good outcome, the FRandR area gives sensitivity 80% (CI 28-99%), NPV 94% (CI 70-100%) and accuracy 95% (CI 75-100%, p = 0.001, chi2 test).
From the paper
When taking as outcome measure the Engel class I (ILAE 1–3), values improve to sensitivity 80%, CI [28–99%], NPV 94%, CI [70 100%], and accuracy 95%, CI [75 100%], p = 0.001 (chi2-test)
Criterion
As table2-frandr-prediction with ILAE 1-3 as good outcome (patients 7 and 8 move from FN to TN). The chi2 readings are those named there; on the paper's counts (a) gives p = 0.0001, (b) p = 0.0012 and (c) p = 0.0010, so the printed value fits (b) or (c), while the p = 0.002 of table2-frandr-prediction fits (a). Reproduced when the three percentages match and p < 0.05 under every reading; each p-value is reported.
In all seizure-free ETE patients (10-16) the resection was limited to 1-2 cm2 and the seizure onset zone was not fully resected, while the FRandR area was always fully resected.
From the paper
While the SOZ was therefore not fully resected in all ETE patients, the HFO area as defined by FRandR was always fully resected.
Criterion
Needs the SOZ channels of patients 10-16, which the paper does not list (it shows them only for patient 17, Fig. 2B). Reproduced when, for each of patients 10-16, at least one SOZ channel is outside the RA and the FRandR area is fully inside it. When the deposit does not mark the SOZ channels either (its data description names none), the SOZ part is not judged and the claim is reported as not testable; the FRandR part alone is already judged by frandr-area-resection-per-patient. The resection size cannot be tested from channel data and is not judged.
In patient 17 (recurrent seizures) the resected area does not comprise all channels of the HFO area, and the HFO area is smaller than the seizure onset zone.
From the paper
The HFO area (contacts filled yellow) is smaller than the SOZ. ( C ) The resected area (RA) does not comprise all channels of the HFO area.
Criterion
FRandR area of patient 17 as in table-s1-rates; resected channels from Table S1 (red). Reproduced when at least one FRandR area channel is outside the RA and at least one is inside it (Discussion, "parts of the HFO area were indeed included"). The comparison with the SOZ is tested only if the SOZ channels are available, as fewer area channels than SOZ channels.
In patient 1 (seizure free) the FRandR area was channel PHR1-2 in each of 4 nights and in the resected area for all intervals, and 99% of the scalar products between interval pairs exceeded significance.
From the paper
The HFO area comprises channel PHR1-2 for each night. The HFO area was stable over nights and included in the RA. ... 99% of the true distribution exceeded significance ... The HFO area was inside the resected area for all intervals.
Criterion
FRandR rates of patient 1 per night (mean over the night's intervals) and per interval; the HFO area per night and per interval by the 95th percentile rule; test-retest as in the opening comment, readings (a) and (b) of the permutation null. Reproduced when the area is PHR1-2 in every night, every per-interval area lies inside the RA (Table S1 red), and the fraction is within tolerance under one reading. With intervals that have no FRandR on any channel the area is empty, which counts as inside the RA.
Across 18 patients the share of significant scalar products had median 97.5% (lower quartile 67%) over pairs of 5-minute intervals and median 100% (lower quartile 100%) over pairs of nights.
From the paper
Across the group of 18 patients (Table 1 ), the percentage of significant scalar products had median of 97.5% (lower quartile 67%) when taking pairs of all 5 minutes intervals, and a median of 100% (lower quartile 100%) when taking pairs of entire nights.
Criterion
Test-retest as in the opening comment, on the 18 patients with more than one interval (all but 7 and 17; night pairs exist only for the 16 with more than one night). Quartiles with Matlab prctile (the Methods name it for percentiles). HFO type readings (a) FRandR, (b) ripples, (c) FR, and permutation null readings (a) and (b) of the opening comment. Reproduced when, under one reading, the four values are within tolerance. The per-patient values are compared with Table 1 and the count within 0.1 of it is reported.
Over intervals, the median share of significant scalar products was above 98% in TLE patients irrespective of outcome, 97% in ETE patients with good outcome and only 36% in ETE patients with poor outcome.
From the paper
Over the intervals of TLE patients, the median was >98% irrespective of outcome. Over the intervals of ETE patients, the median was 97% for patients with good outcome and only 36% for patients with poor outcome.
Criterion
Per-patient interval values from test-retest-group, under the reading that reproduced it. The paper reports no test. "Irrespective of outcome" is read two ways; (a) the median over all 8 TLE patients with more than one interval exceeds 98% (Table 1 gives 0.985); (b) the median exceeds 98% within each outcome group (Table 1 gives 0.985 for ILAE 1 and 0.835 for patients 8 and 9, so the paper's own table does not support (b)). The TLE part is judged on (a), median at least 98% minus 10% of 98. Reproduced when the three values are within tolerance and the ETE poor-outcome median is the lowest.
Of 6182 FRandR events on the highest-rate FRandR channel in each patient's HFO area, 45% had two spectral peaks (second peak median 240 Hz), 28% one peak in the HFO range (median 184 Hz) and 27% no prominent peak above 100 Hz.
From the paper
Out of 6182 detected events, 45% exhibited two distinct peaks in ripple and FR band with the second peak at median frequency 240 Hz (Fig. 4A ), 28% had only one peak in the HFO range (median frequency 184 Hz, Fig. 4B ), and 27% did not show a prominent peak >100 Hz in the HFO range.
Criterion
From the Methods, Spectral analysis. Per patient, the bipolar channel of the FRandR area with the highest FRandR rate; every FRandR event on it; Stockwell transform of 0.6 s of signal centred on the event (st.m of the linked repository); the instantaneous power spectrum averaged over the duration of the FR part of the event (the deposit's FR marking overlapping the FRandR); a fit of four gaussians to the spectrum over 80-500 Hz by least squares (lsqcurvefit); peaks and troughs found on the fitted curve. Bimodal, a trough between 150 and 250 Hz and at least one peak above 200 Hz; unimodal, a single peak above 100 Hz detectable in the ripple band; otherwise no peak. Open, with readings; the centre of the 0.6 s window, (a) the FRandR midpoint, (b) the FR midpoint; the signal transformed, (a) the unfiltered bipolar signal, (b) the signal high-passed at 80 Hz; the gaussian starting values and bounds, not given, (a) four gaussians at 100, 200, 300 and 400 Hz with widths of 50 Hz, (b) starting peaks at the four largest local maxima of the spectrum; a peak, (a) a local maximum of the fitted curve, (b) a fitted gaussian centre with positive amplitude inside the band; the "second peak" of bimodal events, (a) the higher-frequency peak (the Results say it is the second peak "in ripple and FR band"), (b) the more prominent peak (the Discussion calls 240 Hz the median of a prominent peak "around 200 Hz"). Patients whose FRandR area is empty contribute no events. The event count tolerance is 10%. Reproduced when the three shares are within tolerance under one reading and the two median frequencies are; partially reproduced when the shares are in the same order (bimodal largest) under one reading.
The spectral classes of FRandR events did not differ significantly between TLE and ETE channels.
From the paper
No significant difference was observed between TLE and ETE channels.
Criterion
A claim of absence; the paper names no test, only significance at p < 0.05 (Methods, Clinical validation). Main reading, a chi2 test of the 3 x 2 table of spectral class (bimodal, unimodal, none) by epilepsy type over events, at p < 0.05. Variant, a Wilcoxon rank sum test of the per-patient bimodal fraction between the 9 TLE and 11 ETE channels. Reproduced when the main test gives p >= 0.05; the class shares per group and the variant are reported.
In the patients whose HFO area was not fully resected, the area lay outside the resection; in patient 18 over occipital contacts ipsilateral to a resection that included parietal cortex, in patient 19 over the parietal and not the resected temporal cavernoma, and in patient 20 at the anterior margin while the resection was at the posterior margin of the occipito-temporal gyrus.
From the paper
In patient 18, our analysis identified the HFO area over occipital contacts ipsilateral to the resection, which included parietal cortex. ... The HFO area included the parietal cavernoma but not the temporal cavernoma. The surgical choice was to resect only the temporal cavernoma. In patient 20, the resection included the seizure onset area in the posterior margin of the left occipito-temporal gyrus but the HFO area was in the anterior margin.
Criterion
FRandR area channels of patients 18, 19 and 20 as in frandr-area-resection-per- patient. Channel locations from the deposit's electrode schemes and channel labels. For each patient, reproduced when at least one area channel lies outside the RA in the region the Discussion names (patient 18, an occipital contact; patient 19, a contact of the parietal grid; patient 20, an anterior contact of the grid). Judged per patient; reproduced when all three hold, partially when one or two do. Where a contact's region cannot be read from the schemes, that patient is not judged and the notes say why.
Pipeline
- Paper match
- done
- Paper
- done (stored)
- Claims
- done
- Claims check
- done (ready)
- Attempt
- todo
- Questions
- none
- Verified
- none