What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.
Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.
openasked 2026-11-12about figs5-active-inactive-slopes
The claim expects the inactive channels' slope to be +0.54e-3 per day, the sign as Appendix C.2 prints it. The same paragraph calls that slope "near 0", and Section 4.1 says "All categories saw steady decreases in average SBP over time", which covers the active and inactive groups of Figure S5. A positive slope is not a decrease, so the printed value may have lost its minus sign. Should the expected value be -0.54e-3, or should the claim keep +0.54e-3 and record the conflict with Section 4.1?
Passage. "The slopes of the best-fit lines here were −1.29 × 10−3, and 0.54 × 10−3. As might be expected, the slope for the inactive channels was near 0" (Appendix C.2, paragraph after Figure S3); "All categories saw steady decreases in average SBP over time." (Section 4.1, paragraph 2).
Why it matters. The data give -0.536e-3 per day for the inactive channels (channel-session points, stored values), the printed size with the opposite sign. Against +0.54e-3 +- 0.054e-3 it is outside tolerance and the claim is not reproduced; against -0.54e-3 it is inside, and with the active slope (-1.261e-3, inside -1.29e-3 +- 0.129e-3) and the lower SBP of inactive channels the claim would be reproduced.
No reader has answered it yet.
openasked 2026-11-12about fig3e-array-tuning
The criterion follows the sentence of Section 4.2: medial channels tuned to MRS flexion (some IDX flexion), lateral channels to extension of both fingers. The verifier reports that the panels of Figure 3E, which the claim cites as its source, show the reverse: the Lateral bank tuned to flexion, and the Medial 1 and Medial 2 banks near -135 degrees (extension of both), and that Figure 3C agrees with the panels (channels 0 to 31 near 0 to 90 degrees, channels 32 to 95 near -135 to -180). The claims file does not mention this contradiction. Should the claim follow the figure, or keep the sentence and name the contradiction?
Passage. "it appears that channels in the medial array (see Figure 1) are mainly tuned to MRS flexion, with some IDX flexion, while channels in the lateral array are more tuned to extension of both DOF." (Section 4.2, paragraph 1); Figure 3E legend, "Per-channel tuning ranges across the dataset, grouped by bank ... We separated each bank into separate plots."
Why it matters. With the files' array labels (bank A = Lateral, which also gives the lowest SBP and the shallowest slope of Figure S4, and places channel 47 on the medial array as Figure S1 does), 2 of 64 medial channels are in the flexion sector and 2 of 32 lateral channels in the extension sector, so the claim as written is not reproduced. Read as the figure shows it, lateral channels tuned to flexion and medial channels to extension, the data match: 81% of lateral channels are in the flexion sector and 92% of medial channels in the extension sector.
No reader has answered it yet.
openasked 2026-11-12about dataset-contents
The criterion asks for an electrodes table with an impedance column in every file, and partially reproduces the claim when a few files lack a part. Appendix A.2 says that a session with no impedance measured within three weeks has no impedances reported. Should the criterion accept a session without impedances when none were measured within three weeks, as the paper describes the deposit?
Passage. "Each electrode is labeled with the impedance measurement closest in time to the date of the session. If no impedances were recorded within three weeks of a session, no impedances are reported for that session." (Appendix A.2); "Impedance measurements as described above are included in the imp column." (Appendix B.3, Electrodes).
Why it matters. 81 of 312 files have no imp column, and that alone makes the claim partially reproduced. Every other part (the six series, the trials columns, bank, row and column, the 20 ms bins) is present in every file. If a missing impedance is the documented behaviour, the claim would be reproduced, provided the 81 sessions are the ones without a measurement within three weeks, which the files do not let anyone check.
No reader has answered it yet.
openasked 2026-11-12about dataset-sessions
The claims file's opening comment says the 312 sessions run from January 2020 to February 2024. In Appendix B.1 that range describes the candidate days reviewed before curation (453 days), not the final dataset. The final dataset spans 1,242 days (Section 3), which from January 2020 ends in June 2023, and the files run from 2020-01-27 to 2023-06-22. Should the comment say the sessions run from January 2020 to June 2023?
Passage. "we reviewed all experimental notes from Monkey N from January 2020 ... to February 2024 ... After this first pass, we were left with 453 days spanning from January 2020 to February 2024." (Appendix B.1, Initial Candidate Selection); "on 303 days spanning 1,242 days" (Section 3).
Why it matters. It cannot change an outcome: no criterion uses the end date. It misdescribes the data the paper used, so a reader of the claims file would look for sessions after June 2023 that are not in the dataset or the paper.
No reader has answered it yet.
openasked 2026-11-12about fig5a-long-term-decay
The criterion fits a*exp(b*x) + c*exp(d*x) from initial values (0.374, 0.00365, 0.134, 0.140), which it gives as those of stability_plotter.ipynb. Both rates in these values are positive, so the fit starts from two growing components. The fitted curves printed in the Figure 5A panel, as the verifier read them, have negative rates (0.229e^-0.183x + 0.268e^-0.006x for one session and 0.134e^-0.140x + 0.374e^-0.004x for five), and the initial values are the five-session coefficients with the signs of the rates dropped. That suggests the code fits a*exp(-b*x) + c*exp(-d*x), so that the criterion's form, or its initial values, misread the code. Should the criterion use the code's form, or start from negative rates?
Passage. "A double-exponential fit (Fig. 5A) to the single-session and 5-session conditions over all evaluation sessions (within 180 days of day 0) show steeper decays in the single-session case" (Section 4.3, paragraph 3), and the fitted equations printed in Figure 5A.
Why it matters. From the criterion's initial values the fits are degenerate (a near-zero component with rate +0.18 for one session, two growing components for five) and the claim is not reproduced. Started from the panel's values, the fits have lower residuals and all three conditions of the criterion hold, under both normalisations (training day, initial rates -0.906 against -0.182, drop to day 5 1.237 against 0.416, long-term intervals overlapping). The round-2 verifier notes that from the panel's values the 95% intervals of the initial rates include zero in all four fits and overlap widely (training day -2.09 to 0.28 against -0.62 to 0.25; test day -1.53 to 0.33 against -1.91 to 0.84), so with 12 day-0 sessions that pass rests on point estimates, and that the criterion's initial values look like the five-session panel values reordered with the signs of the rates dropped.
No reader has answered it yet.
openasked 2026-11-13about fig2a-irregular-shifts
The criterion counts a day as showing irregular shifts when at least five channels differ from their 30-day median by more than three median absolute deviations, and asks for one such day in July to November 2022. On this dataset the rule flags 237 of the 243 days outside that window that have a 30-day baseline, so the shift part holds on almost any period and does not pick out the one the paper names. Should the criterion compare the window with the rest of the recording, for example a higher share of flagged days or a higher daily count than outside it, or a higher threshold, so that it tests what the paper describes?
Passage. "There are periods where groups of channels exhibit irregular shifts (e.g. ~2022-07 to ~2022-11), but these did not affect overall decoding performance." (Section 4.1, paragraph 1; Figure 2A)
Why it matters. Under the rule as written, 38 of 42 window days have five or more shifting channels, so the shift part holds and the claim is reproduced. The rate is the same outside the window (0.974 of window days against 0.975 of other days; median 17 shifting channels a day against 20; with the 30 preceding recording days as baseline, 0.952 against 0.903). A criterion that asks the window to stand out from the rest would likely not be met by this rule, and the shift part of the claim would fail.
No reader has answered it yet.
openasked 2026-10-28about fig2-gross-failures
The criterion judges gross failures at 64 ms only. Should it cover every configuration the paper ran (bin widths of 16 to 128 ms, 80 and 160 s of training, fractions of the neurons), as "in our experiments" may mean?
Passage. Nevertheless, it should be emphasized that, in our experiments, such gross failures occurred only for the UKF and KFlatent (+KF), so reporting SNR yields a conservative appraisal of the merits of the rEFH. (Results, after the definition of SNR)
Why it matters. At 64 ms with all units and 320 s of training no decoder has a negative R2 on this session, so the claim holds trivially. In the other configurations negative R2 also occurs for linear regression, KFobs, static KFlatent and the static rEFH (binwidth_training_neurons.ipynb), so the claim would not be reproduced under the wider reading.
No reader has answered it yet.
openasked 2026-10-28about fig2-refh-kf-best
The paper's 47 Sabes-lab sessions are public on Zenodo (doi:10.5281/zenodo.583331), and the dandiset holds one session that is not in the paper's session list. Should the claims that need the paper's sessions (this one, intro-gain-over-nearest, fig4-advantage-grows, fig4-position, fig5-vel-acc-all-bins, fig5-position-bins, fig6-training-time, fig7-vel-acc-neurons, fig7-position-neurons, fig8-position-variants, fig9-taps, static-refh-position-worse) be marked `data elsewhere` with that deposit, or stay on the dataset?
Passage. O'Doherty J E, Cardoso M M B, Makin J G and Sabes P N 2017 Nonhuman primate reaching with multichannel sensorimotor cortex electrophysiology (https://doi.org/10.5281/zenodo.583331) (reference 26, cited for the data in Methods)
Why it matters. On the dataset these claims are blocked as data_missing, since it holds one session. Marked `elsewhere`, they would be tested on the Zenodo sessions, or blocked as too_large if the eight decoders on 47 sessions do not fit the time limit (here they take about 2 min on one session of 111 units, and the paper's sessions have 171 to 523).
No reader has answered it yet.