What the attempts found about the paper itself: a method or rule it does not give, a place where it disagrees with itself, published code that does something else. What they found about the data is on each dataset’s page.
Where the author or a verifier believed the claims file misread the paper, they asked, citing the paper, and a reader who had not seen the data answered from the paper alone, amending the claims file where it was wrong. The author then ran the claim as answered. Attempts before protocol pilot-11 also asked here for method details the claims file did not give.
The claim is marked `data` set to `dataset` and so is blocked as data missing, and the header says no claim rests on a number found only in Figure 2, source data 1. Yet the criterion says the dynamic range "is the value of Figure 2, source data 1", and that table is public on the eLife site (elife-12727-fig2-data1-v2.docx, doi:10.7554/eLife.12727.005), with a column "Dynamic range (Fmax/Fmin)" per sensor. Should the claim be `data` set to `elsewhere`, on that file, at least for the value in solution?
Passage. Results, Protein engineering, paragraph 6 ("Both jRCaMP1a and jRCaMP1b have higher calcium affinities than RCaMP1h (Figure 2, source data 1). However, jRCaMP1a has very limited dynamic range in cultured neurons and solution (160 ± 25% and 320 ± 10% respectively, mean ± s.d.)"); the legend of Figure 2, source data 1 ("Biophysical properties of purified jRGECO1 and jRCaMP1 sensors ... mean ± s.d.").
Why it matters. As `data` set to `dataset` the claim is blocked as data missing; as `data` set to `elsewhere` its solution value could be tested on the eLife table, so the outcome could change from blocked to tested. The verifier of round 1 raised it (report, problem 7).
No reader has answered it yet.
The Drosophila claims are marked `data` set to `dataset` and blocked as data missing, but the paper's Figure 7, source data 1 to 3 are public on the eLife site (elife-12727-fig7-data1-v2.xlsx, -data2- and -data3-, doi:10.7554/eLife.12727.022 to .024). They hold, per construct and stimulus frequency (1 to 160 Hz), the mean and s.e.m. of dF/F0 and other measures for R-GECO1, jRGECO1a, jRGECO1b, RCaMP1h, jRCaMP1a, jRCaMP1b, GCaMP6s and GCaMP6f. Should this claim, and fly-improved-over-parents, fly-decay-like-gcamp6f, fig7b-5hz-amplitude and fig7c-frequency-tuning, be `data` set to `elsewhere` on these files, for the parts the summaries can test?
Passage. Results, Red protein calcium indicators in Drosophila, zebrafish, and C. elegans, paragraph 1, which cites "Figure 7, source data 1 – 2" for the single AP boost and "Figure 7, source data 3" for the single AP amplitudes and the 160 Hz half decay times; the legends of Figure 7, source data 1 to 3 ("Summary of results shown in Figure 7, figure supplement 1 to 3").
Why it matters. As `data` set to `dataset` the five claims are blocked as data missing. The summary tables give the means the statements quote (for example the 1 Hz dF/F0 of jRGECO1a, 0.116, against the 11.6% of fly-single-ap-amplitude), so some of them could be tested and their outcomes could change. The verifier of round 1 raised it (report, problem 7).
No reader has answered it yet.
The criterion compares the 2 AP half rise and half decay times of fig4g-jrgeco1a-faster with "the GCaMP6f and GCaMP6s values Chen et al. (2013b) report". Chen et al. report, for V1 in vivo (Supplementary Table 3), a 1 AP half decay and a 1 AP rise time to peak, and no half rise and no 2 AP values. Is the comparison meant to be with those 1 AP values, half rise against time to peak, or with some other measure (for example the time to peak of the 2 AP traces)?
Passage. Results, Relationship between spikes and fluorescence dynamics, paragraph 1 ("Measured rise and decay time of jRGECO1a and jRCaMP1a were similar to GCaMP6f and GCaMP6s, respectively (Chen et al., 2013b)"); Figure 4g legend ("Comparison of mean half rise (left) and decay (right) times of jRGECO1a and jRCaMP1a for 2 AP response"); Chen et al. (2013b) Supplementary Table 3 ("Decay t1/2 1 AP (ms)", "Rise tpeak 1AP (ms)").
Why it matters. Tested as written, the claim is not reproduced; the half rise times (15 and 47 ms) are a third or less of Chen et al.'s times to peak (45 and 179 ms), as a half rise is by construction shorter than a time to peak. With the time to peak of the same traces (77 and 285 ms) the rise times are still outside 25%, so the outcome does not change under the variants run, but the measure compared is not the one the claims file names.
No reader has answered it yet.