Papers / Amjad et al. 2025

Amjad et al. 2025 · ACS Chemical Neuroscience

Microinvasive Probes for Monitoring Electrical and Chemical Neural Activity in Nonhuman Primates

Usamma Amjad, Shreya Mahajan, Jiwon Choi, Ritesh Shrivastav, Raymond Murray, Abby Somich, Olivia Coyne, Helen N. Schwerdt

Outcomes of 13 claims

  • 7 reproduced
  • 1 partially reproduced
  • 5 blocked

Summary: Most of the paper's neural findings held in this data, while its insertion and imaging claims could not be tested. Dopamine was higher after large-reward cues, but weakly (p = 0.023), and beta power was lower after large-reward cues and after left cues. A clean sorted unit was found in monkey P. Insertion yields, days of implantation and the two-channel dopamine increase could not be tested without implant records or the second channel; the redox colour plot and monkey P's reward-modulated firing could not be tested because raw FSCV timing does not fit the trials and that file has no events. Recording parameters matched, except a lowest voltage of -0.347 V.

Summary written by the agent that recorded the attempt, from its claims and the agents’ reports. A failure to reproduce may be a failure of the agent.

Reading outcomes Respond to this attempt

Claims

Reproducing Amjad et al. (2025) from dandiset 002013 8 Open in Colab

Reproduced7

  • Reproduced

    EPhys was sampled at 30 kHz in monkey P and 32 kHz in monkey T, and band-pass filtered from 0.1 to 7500 Hz.

    Monkey P's raw timestamps have a median interval of 33.333 µs (30 kHz) and Monkey T's series a rate of 32000…

    Methods, FSCV and EPhys Recordings, paragraph 3ephys-acquisition
    From the paper

    EPhys recordings were made using a unity-gain analog amplifier headstage ... at a sampling frequency of 30 (monkey P) or 32 kHz (monkey T), and bandpass filtered from 0.1 to 7500 Hz.

    Result

    Monkey P's raw timestamps have a median interval of 33.333 µs (30 kHz) and Monkey T's series a rate of 32000 Hz. The Neuralynx settings of both Monkey T channels give a low cut of 0.1 Hz and a high cut of 8000 Hz, inside the tolerance of 7500 Hz but not equal to it; the dandiset's description also says 0.1 to 7500 Hz (printed). Monkey P's file stores no filter settings; its notes, printed in full, and its electrode columns name no filter or cut-off.

  • Reproduced

    In the shape task, forced trials made up 25% of all trials, and the cue-reward association was reversed after blocks of 50 to 300 trials.

    Forced trials are 358 of 1468 (24.4%). The eight complete blocks of the cue-reward association are 71 to 273…

    Methods, Behavioral Tasks, paragraph 2shape-task-structure
    From the paper

    Forced choice trials were also interleaved (25% of all trials) where only one value cue was displayed ... The cue-reward association was reversed after a block of 50–300 trials depending on the session.

    Result

    Forced trials are 358 of 1468 (24.4%). The eight complete blocks of the cue-reward association are 71 to 273 trials long; the first and last blocks, cut by the file, are 61 and 194 trials.

    Deviations from the paper’s method
    • Blocks are found from the image codes of successful forced trials, as choice trials carry no feedback code; a reversal is placed after the last forced trial of the earlier association, so block edges are uncertain by the gap between forced trials.
  • Reproduced

    Single-trial bipolar LFP from site c3bs-c3a shows beta bursts (one to a few cycles of high beta power) whose frequency changes around the cue and other task events.

    With the threshold at the 75th percentile (356 µV²) and bursts of at least 50 ms, the burst rate of 570…

    Figure 3B; Results and Discussion, paragraph 4fig3b-beta-bursts
    From the paper

    Single-trial LFPs measured from another s-μIP are shown to display fluctuations in the frequency of β-band “bursts” (i.e., 1–few cycles of high β-band power) around the cue and other task events

    Result

    With the threshold at the 75th percentile (356 µV²) and bursts of at least 50 ms, the burst rate of 570 large-reward trials is 1.51 per s in the second before the value cue and 1.21 in the second after it (Wilcoxon p = 9.5e-10). The rate changes around the cue at the 50th and 90th percentiles too (p below 1e-40), rising at the 50th and falling at the 90th, so its direction depends on the threshold while the change does not. The rate dips just after the cue (0.51 per s in 0 to 0.25 s) and falls again from 6 s after it, after the feedback. On the smoothed power 95.1% of runs above the 75th percentile last at least 50 ms (median 206 ms), so the minimum length does little; on the unsmoothed envelope the rate also falls after the cue (3.07 to 2.11 per s, p = 6.8e-34). At the deciding threshold the fall in bursts coincides with the drop in beta power after the cue, so it is not separate evidence from the suppression of fig4b-beta-reward.

    Deviations from the paper’s method
    • The paper shows a single trial and does not define a burst; the threshold, minimum length and test were chosen here before the analysis.
  • Reproduced

    Trial-averaged dopamine at site c8dg is higher after large-reward than after small-reward value cues, in successful forced trials of the shape task.

    Over 0 to 3 s after the value cue, the re-referenced dopamine has a median of 1.28 in 85 large-reward trials…

    From the paper

    Higher dopamine levels are observed following the display of large reward associated value cues as compared to small reward cues in monkey T

    Result

    Over 0 to 3 s after the value cue, the re-referenced dopamine has a median of 1.28 in 85 large-reward trials and 0.19 in 80 small-reward trials (Mann-Whitney p = 0.023; 3 trials of 168 have no valid samples in the window). The difference lies in 1.5 to 3 s (p = 0.0072), not 0 to 1.5 s (p = 0.41). The effect is weak. Before the cue the groups differ the other way (p = 0.064). Without re-referencing (the stored da) there is no difference (p = 0.3), nor in the re-referenced oxidation current (p = 0.41). It holds in trials 1 to 367 (p = 0.013) and not in trials 368 to 734 (p = 0.51). With a baseline of the mean over -1 to 0 s in place of the sample at the cue the result is the same (1.38 against 0.10, p = 0.022).

    Deviations from the paper’s method
    • Only the first 734 of 1468 trials of the session have trial-aligned FSCV in the dandiset, so 168 successful forced trials are used.
    • The stored da is not referenced at the value cue; it is re-referenced here by subtracting its value at the cue, which equals background subtraction there only if the PCA projection was linear and the nulling (NaN) masks are ignored.
    • Small reward is inferred from the absence of the big-reward code, confirmed by the cue condition codes 35 and 36 in all 303 successful forced trials.
    • The paper gives no window or test; 0 to 3 s and the Mann-Whitney test were chosen before the analysis.
  • Reproduced

    Beta-band LFP power at c3bs-c3a in the direction task is more suppressed (stronger event-related desynchronization) after large-reward than after small-reward value cues, in a brief window after the cue.

    Over 0 to 0.5 s after the value cue, median beta power is 275 µV² in 570 large-reward trials and 327 µV² in…

    From the paper

    Trial-averaged β-band LFP power for large and small reward conditions in the direction task, showing increased suppression (i.e., ERD, highlighted in yellow) for large as compared to small reward cues during the brief time window following the value cue at 0 s

    Result

    Over 0 to 0.5 s after the value cue, median beta power is 275 µV² in 570 large-reward trials and 327 µV² in 602 small-reward trials (ratio 0.84, Mann-Whitney p = 1e-08), with no difference before the cue (ratio 1.006, p = 0.82). It holds relative to pre-cue power (ratio 0.82, p = 1.1e-06) and on each side (left p = 0.0016, right p = 1e-07). It is confined to a brief window, as the legend says; over 0 to 1 s large is slightly higher (ratio 1.04, p = 0.09) and over 0.25 to 0.75 s there is no difference (p = 0.66). The 0.25 s smoothing does not carry the difference from before the cue; on the unsmoothed envelope it holds over 0 to 0.5 s (ratio 0.834, p = 1.9e-08) and 0.125 to 0.5 s (ratio 0.671, p = 4.8e-19); in 0.1 s bins large and small do not differ before the cue (ratios 0.95 to 1.05), large is lower from 0.1 to 0.4 s (0.85, 0.59, 0.60) and higher from 0.5 s on (1.32 to 1.49). The criterion, lower power over 0 to 0.5 s, is met; the bins fit a deeper suppression after large-reward cues and equally an earlier suppression with an earlier rebound, so the part of the claim saying the suppression is greater is not shown. The LFP's 1497 joins do not step (largest change at a join 20.3 µV, below the 99.9th percentile of 26.0 µV over all samples), and 118 of 1172 successful trials have one within -0.5 to 1 s of the cue, 23 to 36 in each reward and side condition. Trial 1501, absent from the Zenodo lists, is included; one trial of 570 cannot change the result.

    Deviations from the paper’s method
    • The paper does not give the window highlighted in Figure 4B or a test; 0 to 0.5 s and the Mann-Whitney test were chosen before the analysis.
  • Reproduced

    With the reward fixed at large, beta-band LFP power is more suppressed when the cue is on the left (contralateral) than on the right (ipsilateral).

    Among large-reward trials, median beta power over 0 to 0.5 s is 245 µV² for left cues and 301 µV² for right…

    From the paper

    Increased suppression for contralateral is observed as compared to ipsilateral movement conditions.

    Result

    Among large-reward trials, median beta power over 0 to 0.5 s is 245 µV² for left cues and 301 µV² for right cues (282 and 288 trials, ratio 0.81, Mann-Whitney p = 1.6e-06). Before the cue left is slightly higher (ratio 1.095, p = 0.013), so relative to pre-cue power the difference is larger (ratio 0.71, p = 2.1e-09). It holds over 0 to 1 s (p = 0.019), not over 0.25 to 0.75 s (p = 0.75), and also in small-reward trials (p = 1.5e-10). On the unsmoothed envelope left is lower over 0 to 0.5 s (ratio 0.807, p = 1.7e-06) and 0.125 to 0.5 s (ratio 0.688, p = 3.2e-17), most from 0.1 to 0.3 s (ratios 0.54 and 0.55).

    Deviations from the paper’s method
    • Left is taken as contralateral, as the Methods state; the files do not say which hemisphere was implanted.
    • Window and test chosen before the analysis, as for fig4b-beta-reward.
  • Reproduced

    The s-µIP recorded a spike-sorted unit in monkey P, shown by its average waveform and its interspike interval histogram.

    Plexon unit 1 has 31247 spikes at 2.61 Hz.

    Figure 5B and 5Cfig5bc-unit-isolation
    From the paper

    Average spike waveform ± standard deviation. ... Interspike interval (ISI) histogram showing the distribution of the timing between spikes detected.

    Result

    Plexon unit 1 has 31247 spikes at 2.61 Hz. One of 31246 interspike intervals is under 1 ms (0.003%), and its mean waveform trough (-30.6 µV) is 5.66 times the raw noise level (5.41 µV, 300 to 6000 Hz, 600 s). The units table's unit 0 (unsorted and poor-quality spikes merged) has 11.65% of intervals under 1 ms and is not a unit.

    Deviations from the paper’s method
    • The noise level and the two thresholds are common choices; the paper shows the waveform and histogram without numbers.
    • The paper names the site c33; the file names it cl3. The session is taken as the paper's.

Partially reproduced1

  • Partially reproduced

    FSCV applied a triangular waveform from -0.4 to 1.3 V at 400 V/s, every 100 ms (10 Hz).

    The applied voltage runs from -0.347 to 1.340 V at 400.5 V/s, one scan every 0.1 s.

    Methods, FSCV and EPhys Recordings, paragraph 2fscv-waveform
    From the paper

    FSCV operates by applying a triangle waveform from −0.4 to 1.3 V at a rate of 400 V/s ... The triangular waveform is applied every 100 ms for an effective sampling frequency of 10 Hz.

    Result

    The applied voltage runs from -0.347 to 1.340 V at 400.5 V/s, one scan every 0.1 s. Three of four values are within tolerance; the lowest potential is outside -0.4 +- 0.04 V. The dandiset's own description (-0.35 to 1.34 V) agrees with the data, so the Methods state the nominal waveform. The data of the applied voltage have conversion 1 and offset 0, so the values are read as stored.

    Deviations from the paper’s method
    • Measured on session 09/13/2024 only, the only FSCV session in the dandiset.

Not tested in a notebook 5

3 data missing from the dataset, 2 metadata insufficient

Blocked5

  • Blocked

    Insertion yields were low, 21.4% (3 of 14 sensors) in monkey T and 33% (3 of 9) in monkey P, counted as recording sites that stayed functional after insertion until the end of the study.

    The dandiset holds one or two sites per session and no list of the implanted sensors or of which kept working…

    Data missing from the datasetResults and Discussion, paragraph 3insertion-yield
    From the paper

    insertion yields remained low ranging from 21.4% (3/14 individual sensors) in monkey T to 33% (3/9) in monkey P. These values indicate the number of recording sites that retained functionality after insertion, until the end of this study.

    Result

    The dandiset holds one or two sites per session and no list of the implanted sensors or of which kept working, in its files or its metadata. None of the ten file names of the paper's Zenodo deposit, printed in the data check, points to such a list.

  • Blocked

    The s-µIPs kept recording for more than a year after implantation; the example sites were recorded 483 days (c8dg), 496 days (c3bs-c3a) and 390 days (monkey P) after implantation.

    The subject, device and electrode fields of the files hold no implantation date, and none of the mentions of…

    Metadata insufficientFigure 3A, 3B and Figure 5 legends; Results and Discussion, paragraph 6chronic-duration
    From the paper

    sites c8dg and c8ds: 483 days postimplant ... site c3bs-c3a: 496 days postimplant ... site c33:390 days postimplant ... Measurements were made from chronically implanted s-μIPs that maintained functionality >1 year postimplant.

    Result

    The subject, device and electrode fields of the files hold no implantation date, and none of the mentions of implantation in the files' general section or the dandiset metadata (all printed in the data check) comes with a date, so days post-implant cannot be computed. The two Monkey T sessions are 13 days apart, which matches the difference between the 483 and 496 days of the legends.

  • Blocked

    Dopamine was measured from two neighbouring channels of one dual-channel s-µIP (sites c8dg and c8ds, 0.1 to 0.2 mm apart), and both showed dopamine increases after the value cue in a single forced large-reward trial.

    The dandiset holds FSCV from site c8dg only.

    Data missing from the datasetFigure 3A; Results and Discussion, paragraph 4fig3a-dual-channel
    From the paper

    These measurements also demonstrate the ability to measure dopamine from two neighboring channels on a single s-μIP with 0.1–0.2 mm separation between the recording tips. ... (e.g., increases in both channels after the value cue, V).

    Result

    The dandiset holds FSCV from site c8dg only. Site c8ds is not in it, and the Zenodo deposit holds processed FSCV of c8dg only; its one FSCV file is FSCV_trlists_c8dg_09132024_firsthalf.mat (file list printed in the data check). The c8dg half can be tested and holds; the mean of the re-referenced dopamine over 0 to 3 s is above zero in 56 of 85 large-reward forced trials (65.9%), and in 58 of 85 with a baseline of the mean over -1 to 0 s.

  • Blocked

    The single-trial FSCV colour plot shows dopamine redox current, with changes near 0.6 V (oxidation) and -0.2 V (reduction) after the value cue.

    The raw FSCV current is in the dandiset, but its timing could not be linked to the trials.

    Metadata insufficientFigure 3Afig3a-redox-peaks
    From the paper

    Color plot shows clear dopamine redox current (i.e., color changes ∼0.6 and −0.2 V).

    Result

    The raw FSCV current is in the dandiset, but its timing could not be linked to the trials. Its scan times are an exact 0.1 s grid starting at the first trial start and running 24120 s, past the last trial; at 0.6 V it does not match the stored oxidation current of any of six rows tested at the stored times (|r| below 0.06) or anywhere in the record (best r 0.16 to 0.20 at offsets that differ from row to row); and it shows no large-against-small contrast at the stored value cue times (p = 0.46). The same search at 0.50 V, 0.70 V and -0.19 V gives best r 0.17 to 0.22 at offsets that differ from row to row. Computed at the stored times (not deciding), the background-subtracted voltammogram of 164 large-reward forced trials has its largest rising-sweep value at -0.24 V (at 0.6 V it is -0.033) and its most negative value at the switching potential, 1.34 V, with an SD of 0.042 over the scan; it does not meet the criterion. A colour plot of a forced large-reward trial therefore cannot be placed in the trial.

  • Blocked

    Spikes recorded from an s-µIP in the caudate of monkey P (site c33, 390 days post implant) fire at a different rate for large and small reward during the value cue fixation of the direction task.

    Monkey P's file has no trials table and no events, so value cue times and reward sizes are not in the…

    Data missing from the datasetFigure 5A; Results and Discussion, paragraph 5fig5a-spike-reward
    From the paper

    Spike measurements from an s-μIP in the CN of monkey P also displayed reward-modulated differences in firing rate during the value cue fixation window

    Result

    Monkey P's file has no trials table and no events, so value cue times and reward sizes are not in the dandiset. The paper's Zenodo deposit has the session's raw Neuralynx events (session126_events.mat) as TTL values without names; their codes differ from those of the Monkey T sessions, so they could not be decoded (metadata insufficient). The notebook now reads that file, with 20812 events with 36 distinct TTL values and no names; the trial-start code 128 does not occur and the value cue code 23 occurs 20 times.

Notebooks

Every registered entry that uses the paper’s datasets. An entry can hold several notebooks, and can use more than one dataset.

Reproduction Microinvasive probes for dopamine, LFP and spikes in monkeys (Amjad et al. 2025)

Tests the findings of Amjad, Mahajan, Choi, Shrivastav, Murray, Somich, Coyne and Schwerdt (2025) on dandiset 002013, which holds the three example sessions of the paper. It checks the recording parameters and task structure, the dopamine response to large and small reward cues at site c8dg, beta-band LFP suppression by reward and cue side at c3bs-c3a, beta bursts around the cue, and the isolation of the sorted unit of monkey P, and compares the dandiset with the paper's Zenodo deposit. All files

Environment: Python 3.13, 101 packages pinned in requirements.lock.txt; CI runs each notebook from a new environment built from it.

Verification

  • Round 1
    2026-10-15
    Agreed with 14 of 14 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The first executed notebook with the conclusion cells and the summary removed, the helper module and the claims file, with the paper's full text (PMC12183687). The verifier read the archive's file list and metadata through the DANDI API and tested the helpers on synthetic inputs (beta_power, burst_onsets, window_mean, codes_per_trial, rereference, fscv_window_mean, best_lag, reward_blocks). It had no attempt record and took the claims from the claims file.
  • Round 2
    2026-10-15
    Agreed with 14 of 14 outcomes. Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook). Reviewed: The full executed notebook of the first revision, the helper module, the claims file, the attempt record, the README and its own round-1 report, with the paper's full text (PMC12183687).

Method differences

How the tests differed from the paper’s method or data, and the claims each applies to.

  • Measured on session 09/13/2024 only, the only FSCV session in the dandiset.fscv-waveform
  • Blocks are found from the image codes of successful forced trials, as choice trials carry no feedback code; a reversal is placed after the last forced trial of the earlier association, so block edges are uncertain by the gap between forced trials.shape-task-structure
  • The beta filter (4th-order Butterworth, forwards and backwards, squared Hilbert envelope) is a common choice; the paper's code is not public, and r = 0.943 suggests its filter differs somewhat.zenodo-link
  • The paper shows a single trial and does not define a burst; the threshold, minimum length and test were chosen here before the analysis.fig3b-beta-bursts
  • Only the first 734 of 1468 trials of the session have trial-aligned FSCV in the dandiset, so 168 successful forced trials are used.fig4a-dopamine-reward
  • The stored da is not referenced at the value cue; it is re-referenced here by subtracting its value at the cue, which equals background subtraction there only if the PCA projection was linear and the nulling (NaN) masks are ignored.fig4a-dopamine-reward
  • Small reward is inferred from the absence of the big-reward code, confirmed by the cue condition codes 35 and 36 in all 303 successful forced trials.fig4a-dopamine-reward
  • The paper gives no window or test; 0 to 3 s and the Mann-Whitney test were chosen before the analysis.fig4a-dopamine-reward
  • The paper does not give the window highlighted in Figure 4B or a test; 0 to 0.5 s and the Mann-Whitney test were chosen before the analysis.fig4b-beta-reward
  • Left is taken as contralateral, as the Methods state; the files do not say which hemisphere was implanted.fig4c-beta-side
  • Window and test chosen before the analysis, as for fig4b-beta-reward.fig4c-beta-side
  • The noise level and the two thresholds are common choices; the paper shows the waveform and histogram without numbers.fig5bc-unit-isolation
  • The paper names the site c33; the file names it cl3. The session is taken as the paper's.fig5bc-unit-isolation

Provenance

Attempt record
amjad-2025-01
Paper
Microinvasive Probes for Monitoring Electrical and Chemical Neural Activity in Nonhuman Primates
Date
2026-10-15
Made by
An agent, run by CatalystNeuro
Dataset
DANDI:002013 (on DANDI)
Version
0.261012.0921 (doi:10.48324/dandi.002013/0.261012.0921)
Check that the dataset is the paper’s data
Reproduced The dandiset reproduces the processed data the paper deposited on Zenodo; the trial selections and the beta power of the paper's example trial computed from the dandiset agree with the paper's own files.
Trials are matched by number. The decoded selections agree with the four Zenodo lists for 569 of 570, 602 of 602, 594 of 594 and 577 of 578 trials; the only difference is trial 1501, the last of the session, absent from the Zenodo large-reward and right lists. The Zenodo example "trial35" is the 35th trial of the large-reward list (trial 84). Beta power computed here correlates with its trace at r = 0.943 at a lag of 6 ms, with a median amplitude ratio of 0.943, so the dandiset's LFP, its trial times and the beta pipeline used here agree with the paper's files. The Zenodo example's raw LFP variable is a copy of its time variable, so the LFP trace itself could not be compared. The criterion tests only r and was written after r = 0.94 was known. The amplitudes differ (maximum 2184 µV² here against 1560 µV² in the Zenodo trace), so the paper's filter or envelope probably differs from the one used here.
Run on
GitHub Actions
Harness
Claude Code (GitHub Actions)
Model
claude-opus-5-5
Protocol
pilot-7

Transcripts of the agent runs

Each run’s prompt, messages and tool calls, with long output cut and the text of the paper left out, and its final report.

Other data and code used 1

What the attempt used that is not in the dataset: other data, and the paper’s code. Each is as the attempt’s record describes it.

  • 10.5281/zenodo.14826579 Zenodo

    The paper's Zenodo data deposit, read only by the zenodo-link claim. The four lists of successful trial numbers of session 09/26/2024 (files "09262024_trialids_value object start_big rew and success_tr1-1501.mat" and its small rew, left and right counterparts) and the beta power of its example trial (09262024_c3bs-c3a_data_trial35bigrewardexample.mat), used as reference values.

    Source as recorded: doi:10.5281/zenodo.14826579

Badges for this paper

Encore: 7 findings reproduced, Amjad et al. 2025

It counts the paper’s findings reproduced in full by attempts an independent verifier has checked. To show it beside the paper, on a lab’s site or in a repository’s README, linked to this page:

<a href="https://encorescience.org/papers/amjad-2025/"><img src="https://encorescience.org/badge/papers/amjad-2025.svg" alt="Encore: 7 findings reproduced, Amjad et al. 2025"></a>

Or as Markdown:

[![Encore: 7 findings reproduced, Amjad et al. 2025](https://encorescience.org/badge/papers/amjad-2025.svg)](https://encorescience.org/papers/amjad-2025/)

The same numbers are in this page’s JSON, under badge (how it is counted).