Papers tested on this dataset 1
Each opens the paper’s page, with every claim, its outcome and the notebook that tested it.
Open findings about the data 7
What the attempts that used this dataset found about the data themselves, for its owner and the archive, under the version of the dataset each was found on.
Dataset version 1 · tested 2026-11-18 · 7 open findings
- Data missingThe dataset holds no optical maps, traces or ECG. Its derivative workbook gives per-heart summary values for Figure 1 (heart rate only), Figure 2, Figure 3B to 3F and Figures 5F and 7F. The data behind Figure 1 APD, CaTD and CaT amplitude, the paced experiments of Figures 4 and 6, and all activation, repolarization, APD and CaTD maps (Figures 4 to 7) are absent, so 8 of the paper's claims cannot be tested.#
Found by the attempt on Wang et al. 2019 (wang-2019-01, 2026-11-18) - Metadata errordataset_description.xlsx gives 0 subjects and 0 samples, subject.csv and sample.csv are empty, and the curator's note calls the dataset a computational modelling dataset, although the workbook holds measurements from mouse and rabbit hearts (the Methods report 13 mice and 9 rabbits).#
Found by the attempt on Wang et al. 2019 (wang-2019-01, 2026-11-18) - Identifier missingNo table identifies a heart or animal, so hearts cannot be followed across figures or conditions. In the Figure 3F table the no-SNS and SNS columns can be paired only by position, and the second no-SNS column is empty.#
Found by the attempt on Wang et al. 2019 (wang-2019-01, 2026-11-18) - OtherThe Figure 3F table has 4 hearts in its no-SNS series where the legend gives n = 5, and one noradrenaline heart (Figure 3C) has no values at 12.33 s.#
Found by the attempt on Wang et al. 2019 (wang-2019-01, 2026-11-18) - OtherThe deposited mouse APD80 at 60 s of SNS is 49.54 +- 4.94 ms (n = 5), where the Abstract reports 46.5 +- 9.1 ms; the values at 0 s (50.52 +- 4.52) and 15 s (61.18 +- 3.24) are close to the Abstract's 50.9 +- 5.1 and 60.6 +- 4.1. The deposited values are not exactly those the paper summarises.#
Found by the attempt on Wang et al. 2019 (wang-2019-01, 2026-11-18) - OtherIn the Figure 3E table every heart's no-SNS APD80 at 5 s equals its value at 0 s (56.9, 56.02 and 57.3 ms), consistent with the 0 s value being carried over in place of a measurement.#
Found by the attempt on Wang et al. 2019 (wang-2019-01, 2026-11-18) - Description missingThe tyramine and noradrenaline tables (Figure 3B and 3C) label time "SNS Time (sec)" though these hearts were not stimulated, and each has an unlabelled column B (0, 3.5, 3.403, 4.435, 9.469 for tyramine) consistent with the spread of the time points across hearts but not described. The Figure 1 heart rates have no unit and no statement of which part of the 20 s SNS they are.#
Found by the attempt on Wang et al. 2019 (wang-2019-01, 2026-11-18)
Badges for this dataset

It counts every claim tested on this dataset in a current attempt, verified or not, over every paper tested on it. To show it on the dataset’s own page, linked to this page:
<a href="https://encorescience.org/datasets/sparc/212/"><img src="https://encorescience.org/badge/sparc/212-outcomes.svg" alt="Encore: 11 reproduced, 0 partially reproduced, 2 not reproduced, 8 blocked, of 21 claims tested on SPARC:212"></a>
Or as Markdown:
[](https://encorescience.org/datasets/sparc/212/)
The same numbers are in this page’s JSON, under
badge (how it is counted).