Datasets / DANDI:001552

Floeder et al (2025) Mesolimbic dopamine ramps reflect environmental timescales

Joseph R Floeder, Huijeong Jeong, Ali Mohebi, Vijay Mohan K Namboodiri

House mouse 1.1 GB 502 files

Tested on dataset version 0.250828.1728

3 findings reproduced from this dataset. Reproduced in full, by attempts an independent verifier checked.

View on DANDI JSON

Papers tested on this dataset 1

Each opens the paper’s page, with every claim, its outcome and the notebook that tested it.

Continuous Temporal Difference Learning as a Unifying Theory of Dopamine Function

13 reproduced · 4 partially reproduced · 1 blocked
Attempt garud-2026-01 on version 0.250828.1728
Verified2026-11-25

Open findings about the data 6

What the attempts that used this dataset found about the data themselves, for its owner and the archive, under the version of the dataset each was found on.

Dataset version 0.250828.1728 · tested 2026-11-25 · 6 open findings

Problems that change results 2

The data are wrong in a way the files do not show, so an analysis that takes them as given comes out wrong. Each was checked against the notebook’s outputs by someone other than the attempt’s author.

  • Metadata errorChanges resultsTwo recordings are deposited twice under different days. sub-JF-dLight-ramp2-F2 Day3 and Day4 hold identical photometry (381,921 samples), cues and licks, as do sub-JF-dLight-ramp2-F4 Day5 and Day6 (330,189 samples). An analysis that counts sessions counts each of them twice, and one of each pair is filed under a day on which, as far as the files show, no other recording exists.#
    Checked: Shown, and critical is right. Cell 9 shows identical 470 hashes, sample counts (381,921 and 330,189), cue counts and lick counts for F2 Day3/Day4 and F4 Day5/Day6. Cue and lick identity is shown only through the counts. One recording deposited as two, labelled as different days, is critical by definition.
    Found by the attempt on Garud et al. 2026 (garud-2026-01, 2026-11-25)
  • Metadata errorChanges resultsThe photometry and the event log are on different clocks and the files do not say so. Every photometry series states a start of 0 (at most 8 microseconds), while the event log has its own zero; aligned by the TTL2 channel, the photometry starts 3.6 to 251 s before the event log's zero. The only link is photometry_ttl2, described in every file only as "raw photometry channel ttl2", whose rising edges fall on the cue onsets (event code 15). A user who takes both time bases as given places dopamine seconds to minutes away from the cues and rewards.#
    Checked: Shown in substance, and critical is right. Cell 7 shows TTL2 edges fitting cue times within 0.094 s, and the photometry starting 3.6 to 251.3 s before the event-log zero. "Starts at time 0" and the TTL2 description are not printed. Signals on different clocks with no stated link are critical; the 64 files with the wrong rate would make the problem visible, but the other 292 sessions would not.
    Found by the attempt on Garud et al. 2026 (garud-2026-01, 2026-11-25)

Other findings 4

  • Metadata error64 of the 144 JF-FP photometry series state a rate of 120481.9 Hz, or timestamps 8.3 microseconds apart, for signals sampled at 120.3 to 120.5 Hz (fitted from TTL2 edges against cue times), a factor of about 1000. The other files state 130 Hz, which the TTL2 fit confirms.#
    Found by the attempt on Garud et al. 2026 (garud-2026-01, 2026-11-25)
  • Description missingThe 144 files of the 9 JF-VR-FP mice (all opened) hold only raw photometry and TTL channels (session description "photometry_only") with no event log, task parameters, behaviour or processing module, and nothing in the dandiset says which experiment they belong to or how to align them to a task. They cannot be analysed as deposited.#
    Found by the attempt on Garud et al. 2026 (garud-2026-01, 2026-11-25)
  • Description missingThe TTL channels, the eventFlag series (described only as the third column of the event log) and the meaning of the lick code in use (code 5, "Lick3 onset") are not explained, and the stretches where the 470 signal is near zero (about 2950 samples, some 23 s, in JF-dLight-ramp2-M4 Day9 and JF-dLight-ramp2-M5 Day9) are not marked as dropouts.#
    Found by the attempt on Garud et al. 2026 (garud-2026-01, 2026-11-25)
  • OtherThe sessions are in blocks of 8 long-ITI then 8 short-ITI sessions (JF-FP) or 7 or 8 long, 8 short, 7 or 8 long (JF-dLight-ramp2), with median inter-cue intervals of about 53.7 and 16.6 s, and rewards 9 s after each cue. Garud and Morris describe the sessions as alternating across days, with ITIs of ~8 and ~55 s (Results) or ~15 and ~45 s (Methods).#
    Found by the attempt on Garud et al. 2026 (garud-2026-01, 2026-11-25)

Badges for this dataset

Encore: 3 findings reproduced, from DANDI:001552

It counts the findings reproduced in full from this dataset by attempts an independent verifier has checked, over every paper tested on it. To show it on the dataset’s own page, linked to this page:

<a href="https://encorescience.org/datasets/dandi/001552/"><img src="https://encorescience.org/badge/dandi/001552.svg" alt="Encore: 3 findings reproduced, from DANDI:001552"></a>

Or as Markdown:

[![Encore: 3 findings reproduced, from DANDI:001552](https://encorescience.org/badge/dandi/001552.svg)](https://encorescience.org/datasets/dandi/001552/)

The same numbers are in this page’s JSON, under badge (how it is counted).