Datasets / DANDI:001284

NG-CANCAN Remote Targeting Electroporation: Focused Cell Electroporation and Ablation in a Pseudo-3D Model

Giedre Silkuniene, Mantas Silkunas, Olga Pakhomova, Iurii Semenov, Andrei Pakhomov

House mouse 36.4 GB 84 files

Tested on dataset version 0.250701.1610

View on DANDI JSON

Papers tested on this dataset 1

Each opens the paper’s page, with every claim, its outcome and the notebook that tested it.

MHz compression of pulse packets facilitates remote focusing of electroporation

9 reproduced · 5 partially reproduced · 4 not reproduced · 10 blocked
Not yet verified2026-11-20

Open findings about the data 8

What the attempts that used this dataset found about the data themselves, for its owner and the archive, under the version of the dataset each was found on.

Dataset version 0.250701.1610 · tested 2026-11-20 · 8 open findings

  • Data missingPartly fixedDANDI:001047, which cites the paper, holds images from a 3.8-mm array with a 3.2-kV first pulse (per-file metadata and images), not the paper's 15.3-mm array with 7.2-kV pulses. Of the packet-rate series of Figures 3 and 4 (1 Hz to 0.2 MHz) only the 1-Hz, 0.2-MHz and control wells are deposited, in 001276; the 1-kHz and 10-kHz wells are in none of the four dandisets, and neither are the field simulation (Fig. 1), the thermochromic film images (Fig. 2) or the high-resolution images of Fig. 5C. Seven of the paper's claims cannot be tested.#
    Found by the attempt on Silkuniene et al. 2025 (silkuniene-2025-04, 2026-11-20); that attempt also used DANDI:001047, DANDI:001276, DANDI:001277, and the finding does not say which dataset it is about
  • Description missingNewDANDI:001276 holds CT26 and CHO wells exposed at a 1-Hz packet rate and control wells, which its description (0.2 MHz, 1 to 6 bursts) does not mention and whose role in the paper is not stated; by the paper's protocol they fit the packet-rate series of Figures 3 and 4, and a reader's answer assigns four of its claims to them. The CT26 wells at 2 bursts (x4) hold CANCAN at 1 Hz (n = 2) and 0.2 MHz (n = 6) and controls (n = 4), with all three conditions on 13 August 2024.#
    Found by the attempt on Silkuniene et al. 2025 (silkuniene-2025-04, 2026-11-20); that attempt also used DANDI:001047, DANDI:001276, DANDI:001277, and the finding does not say which dataset it is about
  • Selection not documentedStill presentSeveral groups hold more wells than the paper reports. 001284 has 12, 11 and 11 YP wells at 0, 1 and 2 mm (paper n = 6 to 7); 001276 has 5, 8, 7 and 8 CHO wells at 1, 2, 4 and 6 bursts (paper n = 4) and 6 CT26 wells at 2 bursts (paper n = 3 to 5); 001277 has 7 wells labelled 600 ns (paper n = 5). In 001284 the August 2024 YP wells (7, 6 and 7) match the paper's YP n and the October 2024 wells (5, 5 and 4) its Pr n. Which wells the paper used is not recorded.#
    Found by the attempt on Silkuniene et al. 2025 (silkuniene-2025-04, 2026-11-20); that attempt also used DANDI:001047, DANDI:001276, DANDI:001277, and the finding does not say which dataset it is about
  • Metadata errorStill presentIn 001277, wells P1-20240926-B2 and B3 are labelled 600-ns 0.2-MHz CANCAN. In B2 the YP spot is 5.39 mm from the array centre, against at most 1.21 mm in every other 0.2-MHz CANCAN well with footprints; B3 has its YP maximum at the centre, but YP at 3 and 5 mm is 46% and 35% of the centre, against at most 13% and 9% in the other wells of 001277. The label or the exposure of these two wells may differ from the description.#
    Found by the attempt on Silkuniene et al. 2025 (silkuniene-2025-04, 2026-11-20); that attempt also used DANDI:001047, DANDI:001276, DANDI:001277, and the finding does not say which dataset it is about
  • Metadata errorStill presentEvery 001277 file states "9 packets of pulses delivered at 0.2MHz", whatever the pulse duration (counts by duration in the notebook's data check), where the dandiset description and the paper give 18, 9 and 6 packets for 300, 600 and 900 ns. In 001284, the pre-exposure Hoechst files of wells P1-20241002-B2 and P2-20241004-B1 state 900-ns pulses, while the other files of these wells state 600 ns.#
    Found by the attempt on Silkuniene et al. 2025 (silkuniene-2025-04, 2026-11-20); that attempt also used DANDI:001047, DANDI:001276, DANDI:001277, and the finding does not say which dataset it is about
  • File format errorNewThe FITC image of 001284 well P1-20240828-A3 (11 MB) is 98% zero pixels, and the pre-exposure DAPI file of 001276 well P1-20240821-A2 holds only zeros.#
    Found by the attempt on Silkuniene et al. 2025 (silkuniene-2025-04, 2026-11-20); that attempt also used DANDI:001047, DANDI:001276, DANDI:001277, and the finding does not say which dataset it is about
  • OtherStill presentThe Cy3-DAPI image of 001277 well P2-20240925-B3 is deposited twice (sub-P2-20240925-B3_image.nwb and sub-P2-20240925-B3_obj-w6fqmq_image.nwb, identical size and data).#
    Found by the attempt on Silkuniene et al. 2025 (silkuniene-2025-04, 2026-11-20); that attempt also used DANDI:001047, DANDI:001276, DANDI:001277, and the finding does not say which dataset it is about
  • Metadata errorNewThe dandiset descriptions and files give a 10-mm inter-electrode distance, which matches none of the distances the paper gives (15.3 mm between needle edges along a diagonal, 12.8 mm between needle centres along a side, as the electrode footprints in the images confirm).#
    Found by the attempt on Silkuniene et al. 2025 (silkuniene-2025-04, 2026-11-20); that attempt also used DANDI:001047, DANDI:001276, DANDI:001277, and the finding does not say which dataset it is about

Badges for this dataset

Encore: 9 reproduced, 5 partially reproduced, 4 not reproduced, 10 blocked, of 28 claims tested on DANDI:001284

It counts every claim tested on this dataset in a current attempt, verified or not, over every paper tested on it. To show it on the dataset’s own page, linked to this page:

<a href="https://encorescience.org/datasets/dandi/001284/"><img src="https://encorescience.org/badge/dandi/001284-outcomes.svg" alt="Encore: 9 reproduced, 5 partially reproduced, 4 not reproduced, 10 blocked, of 28 claims tested on DANDI:001284"></a>

Or as Markdown:

[![Encore: 9 reproduced, 5 partially reproduced, 4 not reproduced, 10 blocked, of 28 claims tested on DANDI:001284](https://encorescience.org/badge/dandi/001284-outcomes.svg)](https://encorescience.org/datasets/dandi/001284/)

The same numbers are in this page’s JSON, under badge (how it is counted).