?Not reproducedResults, 3.2 Neuronal firing, paragraph 5; Figure 2d
Among maintenance neurons, a significant number increased firing with workload in hippocampus (10 of 55, 18%) and entorhinal cortex (5 of 21, 24%), and a significant number decreased firing with workload in hippocampus (6 of 55, 11%); in entorhinal cortex 2 decreased and in amygdala 1 increased, not significant.
we found a significant number of maintenance neurons that showed an increase in firing with workload in the hippocampus (10/55 = 18%, permutation test against scrambled labels, p = .002, Fig. 2 d) and entorhinal cortex (5/21 = 24%, permutation test against scrambled labels, p = .002). We also found a significant number of maintenance neurons that showed a decrease in firing rate with workload in the hippocampus (6/55 = 11%, permutation test against scrambled labels, p = .002).
Results, 3.2 Neuronal firing, paragraph 5; Figure 2d
What the paper reports
- increase with workload, hippocampus: permutation test against scrambled labels, p = 0.002 (n = 55 hippocampal maintenance neurons)
- increase with workload, entorhinal cortex: permutation test against scrambled labels, p = 0.002 (n = 21 entorhinal maintenance neurons)
- decrease with workload, hippocampus: permutation test against scrambled labels, p = 0.002 (n = 55 hippocampal maintenance neurons)
Measured values are for the paired maintenance neurons, the per-neuron permutation t-test (reading a) and regions by tip location (a2; a1 gives the same counts). Hippocampal increase 2 (p = 0.43 against 499 shuffles of set-size labels), entorhinal increase 0 (p = 1), hippocampal decrease 2 (p = 0.49), entorhinal decrease 2 (p = 0.09), amygdala increase 1 (p = 0.29). By electrode name the counts are 2 (p = 0.30), 1 (p = 0.50), 2 (p = 0.38), 3 (p = 0.042) and 0. The unpaired maintenance neurons give 2, 0, 2, 2 and 1 by tip location and 2, 1, 2, 2 and 0 by electrode name, no named count below p = 0.25; the cluster-based test (reading b, 99 shuffles) 1, 0, 1, 0 and 0 under both region readings. With every session's spikes moved by three trials (variant, electrode name) the counts are 1, 1, 1, 1 and 0. The expected count under shuffled labels is 0 to 1. None of the three named counts is near 10, 5 or 6 or significant, under any region reading. The data check suggests the spikes may be misaligned with the trial labels, so this failure may come from the deposited data; moving every session by three trials does not recover the counts.
How the test differed from the paper’s method
- Reading (b), the cluster-based test, uses rates in 500 ms windows stepped by 50 ms (the Figure 2a legend gives 500 ms bins with a 1 ms step), a two-sided t threshold at p < .05 and the 95th percentile of the largest cluster mass over 1000 label permutations; its counts use 99 label shuffles, not 499, for time.