The maximum inhibition of YP uptake, down to ~20% of the unipolar pulses, was achieved with the 2 nd phase set to 50-75% of the first one (p<0.01, Fig. 2C ).
Results 3.1, paragraph 2; Figure 2C and its legend
What the paper reports
- two-sided Student's t-test, p < 0.01 (n = 3 to 8 exposures per protocol)
Over the ROI from 8.94 to 15.24 kV/cm (nearest 8.7 and 15.1), the 50% second phase inhibits most and the lower of 50 and 75% is below 25 and 100% at every ROI, so the ordering holds. The percent of the unipolar mean is 54.5% averaged over the range (reading a, given as measured) and 31.6% at its lowest, at 14.24 kV/cm (reading b), both outside 18 to 22%, so the claim is at most partially reproduced. Where the p < 0.01 test is made is not given; four readings are run. At every ROI of the range it fails for both amplitudes (largest p for 50%, 0.79 against unipolar and 0.072 against 25 and 100%; for 75%, 0.996 and 0.249); on dish means over the range it fails (smallest p 0.011, 50% against 25 and 100%, normalised values); at both named fields it fails (50% against unipolar, p 0.79 at 8.94 and 0.0018 at 15.24 kV/cm). At one ROI or more it holds, 50% against unipolar at 15.24 kV/cm (p 0.0018), the only one of 36 tests (2 amplitudes, 2 comparisons, 9 ROI) below 0.01; that reading would give partially reproduced. At the ROI of strongest inhibition (14.24 kV/cm) p is 0.027 against unipolar and 0.019 against 25 and 100%. With the right footprint alone the pooled test reaches p < 0.01 (partially reproduced); every other variant gives not reproduced under the first three readings. The 100% dishes show more uptake than the unipolar dishes at most ROI (89.6 to 229.9% of unipolar), which the paper does not report.
How the test differed from the paper’s method
- Where the p < 0.01 test is made is not given (claims file, criterion; Results 3.1 cites only "Fig. 2C"). It is run at every ROI of the range, on each dish's mean over the range, at both named fields, and at one ROI or more. The outcome assumes the paper's p < 0.01 applies over the range of fields where it reports the inhibition (the first three readings, which agree), not to one ROI chosen from 36 tests; the per-ROI p values are printed.
- The range from 8.7 to 15.1 kV/cm is read as the ROI nearest each named field and those between (claims file, opening comment), j 1 to 9; the central ROI (15.38 kV/cm) is above 15.1 in the recomputed field. With the field scaled so that the centre is at 15.1 kV/cm the range starts at the centre ROI, and the mean percent is 52.9%.
- ROI placement, footprints, field and the missing third unipolar dish as for fig2a-uptake-rises-with-field.