Datasets / DANDI:000165

Aery Jones et al (2021) Dentate Gyrus and CA3 GABAergic Interneurons Bidirectionally Modulate Signatures of Internal and External Drive to CA1

Emily Aery Jones, Antara Rao, Misha Zilberter, Biljana Djukic, Anna K. Gillespie, Nicole Koutsodendris, Maxine Nelson, Seo Yeon Yoon, Ky Huang, Heidi Yuan, Theodore M. Gill, Yadong Huang, Loren M. Frank

behavioral electrophysiological House mouse 98.0 GB 572 files

Tested on dataset version 0.211118.1526

5 findings reproduced from this dataset. Reproduced in full, by attempts an independent verifier checked.

View on DANDI JSON

Papers tested on this dataset 1

Each opens the paper’s page, with every claim, its outcome and the notebook that tested it.

Aery Jones et al (2021) Dentate Gyrus and CA3 GABAergic Interneurons Bidirectionally Modulate Signatures of Internal and External Drive to CA1

5 reproduced · 3 partially reproduced · 31 not reproduced · 3 blocked
Attempt jones-2021-01 on version 0.211118.1526
Verified2026-11-15

Open findings about the data 10

What the attempts that used this dataset found about the data themselves, for its owner and the archive, under the version of the dataset each was found on.

Dataset version 0.211118.1526 · tested 2026-11-15 · 10 open findings

Problems that change results 2

The data are wrong in a way the files do not show, so an analysis that takes them as given comes out wrong. Each was checked against the notebook’s outputs by someone other than the attempt’s author.

  • File format errorChanges resultsThe MUA spike times are not on the clock of the LFP. CA1 MUA peaks around the SWRs detected on the LFP in 261 of 311 analysed home cage sessions, but displaced from the SWR midpoint by a session-specific lag (median -0.145 s, quartiles -0.395 to -0.055 s, range about -2 to +1 s, the MUA earlier in most sessions); only 26 sessions have the peak within 20 ms. With the deposited times the mean normalised CA1 MUA during SWRs is 0.39 SD (median -0.2); with each session shifted by its lag, 1.73 SD.#
    Checked: rest_home_cage.ipynb cell 8 prints 261 of 311 sessions with a clear CA1 MUA peak, lag median -0.145 s (quartiles -0.395 to -0.055, min -1.985, max 0.945), 26 sessions within 20 ms, and mean SWR MUA 0.389 SD (median -0.2) as deposited against 1.729 after the shift. The shifted value is raised partly by construction, since each lag is chosen at the peak, and the lag code itself is in a helper module that is not printed.
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)
  • OtherChanges resultsSession Chakotay01 (home cage) is deposited twice, as sub-Chakotay_ses-Chakotay01-HomeCage and sub-Chakotay_ses-Chakotay01_HomeCage, with the same LFP length, spike count and start time.#
    Checked: rest_home_cage.ipynb cell 3 prints the two Chakotay01 home cage files (ses-Chakotay01-HomeCage and ses-Chakotay01_HomeCage) with the same 3701569 LFP samples, 174198 spikes and start time 2017-07-03T15:06:45. The sample values themselves were not compared, but the match of all three is one session deposited under two session ids.
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)

Other findings 8

  • Metadata errorFour 4-shank mice (Beverly and Worf, PV-Cre; Picard and Riker, SST-Cre) have only home cage sessions labelled CNO, numbered 8 to 17, so they have no vehicle sessions as deposited; the paper analyses 16 PV-Cre and 16 SST-Cre mice with vehicle and CNO.#
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)
  • Metadata errorIn cohort 3 every mouse has its vehicle sessions before its CNO sessions, on the track and in the home cage, where the Methods say the treatments alternated; cohort 2 alternates. Either the labels or the description is wrong. As deposited, treatment is confounded with session order, and the empty vector mice change with CNO in 4 rest and 9 run features, and run faster on CNO days.#
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)
  • OtherThe scale of the LFP values is unclear. The unit attribute says microvolts, and the ripple-band envelope over rest (mean 68.8 file units over 311 home cage sessions) is close to Table S2's 72.39 uV. But the SW amplitude in vehicle sessions is about 3000 file units against Table S4's 375 and 385 uV, the rest SG power matches Table S2 neither in file units nor scaled by 0.195, and values reach the int16 limits in 123 of 311 home cage sessions.#
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)
  • Metadata errorThe session start times of the linear track files put all sessions of a mouse within minutes of each other (shortest gap 0.9 to 4.6 min in all 30 mice), which cannot be right for 25 min sessions.#
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)
  • OtherHome cage sessions of cohort 3 last about 25 min and track sessions about 25 min, where the Methods give 60 and 30 min; many cohort 2 mice have 7 home cage sessions where the Methods give 6.#
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)
  • File format errorEvery unit's spike train begins with a spike at exactly 0.0 s (about 31 per session, one per site), which is not a recorded spike.#
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)
  • Description missingThe electrode location labels carry undocumented tokens ("ca1-pyr 1", "mua", "dg-val gc"). They were read as the SWR detection site, the highest-MUA site of a region, and DG sites with confirmed dentate spikes, from the Methods' wording; the dandiset does not say so. The session description says "1 hour after CNO injection" for vehicle sessions too.#
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)
  • OtherOn the linear track, position and LFP agree to within about 2 s: the log theta/delta power ratio correlates with speed at zero lag (mean r 0.134, positive in 141 of 170 sessions) and not with speed shifted by 30 s or more (mean 0.009). The sub-second spike offset found in the home cage could be checked on the track in only 24 of 170 sessions, those with a clear CA1 MUA peak around SWRs in still periods (median lag -0.245 s).#
    Found by the attempt on Jones et al. 2021 (jones-2021-01, 2026-11-15)

Badges for this dataset

Encore: 5 findings reproduced, from DANDI:000165

It counts the findings reproduced in full from this dataset by attempts an independent verifier has checked, over every paper tested on it. To show it on the dataset’s own page, linked to this page:

<a href="https://encorescience.org/datasets/dandi/000165/"><img src="https://encorescience.org/badge/dandi/000165.svg" alt="Encore: 5 findings reproduced, from DANDI:000165"></a>

Or as Markdown:

[![Encore: 5 findings reproduced, from DANDI:000165](https://encorescience.org/badge/dandi/000165.svg)](https://encorescience.org/datasets/dandi/000165/)

The same numbers are in this page’s JSON, under badge (how it is counted).