Datasets / CRCNS:ssc-8

Two photon calcium imaging recordings of spontaneous activity from mouse somatosensory cortex in wild-type and Fmr1 knock-out mice from three developmental age groups.

J.T Gonçalves, C. O’Donnell, T.J. Sejnowski, C. Portera-Cailliau

microscopy House mouse 4.2 GB 4 files

Tested on dataset unversioned files (the archive keeps no versions)

5 findings reproduced from this dataset. Reproduced in full, by attempts an independent verifier checked.

View on CRCNS JSON

Papers tested on this dataset 1

Each opens the paper’s page, with every claim, its outcome and the notebook that tested it.

Circuit level defects in the developing neocortex of Fragile X mice

5 reproduced · 3 partially reproduced · 3 not reproduced · 17 blocked
Attempt goncalves-2013-01 on unversioned files (the archive keeps no versions)
Verified2026-11-08

Open findings about the data 6

What the attempts that used this dataset found about the data themselves, for its owner and the archive, under the version of the dataset each was found on.

Dataset unversioned files (the archive keeps no versions) · tested 2026-11-08 · 6 open findings

  • Selection not documentedThe data set holds 13, 8 and 7 WT mice and 9, 10 and 6 Fmr1 -/- mice at P9-11, P14-16 and P30-40 (53), while the paper analysed 12, 9 and 8 and 9, 10 and 8 (56). Neither the descriptor nor the files say which mice differ from the paper's sample or why.#
    Found by the attempt on Goncalves et al. 2013 (goncalves-2013-01, 2026-11-08)
  • Metadata errorThe descriptor gives 40 to 149 neurons per animal; two WT P9-11 recordings have 164 and 198. It gives about 7 to 8 min per recording; at the stated 3.9 Hz the recordings last 3.8 to 15.4 min, and 27 of 53 are 2160 frames (9.2 min).#
    Found by the attempt on Goncalves et al. 2013 (goncalves-2013-01, 2026-11-08)
  • Description missingThe descriptor gives no unit for the estimated firing rates; their means fit Hz, and the values, which are continuous, do not show the unit. It does not say that the k-th matrix of each group belongs to Movie_k.tif, which the frame counts and the correlation of the population rate with each movie's brightness show.#
    Found by the attempt on Goncalves et al. 2013 (goncalves-2013-01, 2026-11-08)
  • OtherThe movie folders are named "4Hz" where the paper and the descriptor give 3.9 Hz, and most recordings are 2160 frames, three 3-min movies at 4 Hz. Frames are 128 x 256 pixels in 50 movies (and 357, 404 and 512 wide in one each), where the Methods give 512 x 128. The TIFFs carry no time stamps, so the frame rate cannot be checked.#
    Found by the attempt on Goncalves et al. 2013 (goncalves-2013-01, 2026-11-08)
  • Data missingNo cell contours or dF/F traces are deposited, so the paper's correlations cannot be computed from the filtered dF/F if that is what the paper used; only the estimated firing rates are given. The whole-cell recordings, the EEG, the isoflurane imaging and the 15.6 Hz imaging are not deposited, and 17 of the paper's 28 claims cannot be tested.#
    Found by the attempt on Goncalves et al. 2013 (goncalves-2013-01, 2026-11-08)
  • File format errorThe TIFF archive holds five macOS resource-fork files (._.DS_Store and ._Movie_1.tif) beside the 53 movies.#
    Found by the attempt on Goncalves et al. 2013 (goncalves-2013-01, 2026-11-08)

Badges for this dataset

Encore: 5 findings reproduced, from CRCNS:ssc-8

It counts the findings reproduced in full from this dataset by attempts an independent verifier has checked, over every paper tested on it. To show it on the dataset’s own page, linked to this page:

<a href="https://encorescience.org/datasets/crcns/ssc-8/"><img src="https://encorescience.org/badge/crcns/ssc-8.svg" alt="Encore: 5 findings reproduced, from CRCNS:ssc-8"></a>

Or as Markdown:

[![Encore: 5 findings reproduced, from CRCNS:ssc-8](https://encorescience.org/badge/crcns/ssc-8.svg)](https://encorescience.org/datasets/crcns/ssc-8/)

The same numbers are in this page’s JSON, under badge (how it is counted).