Papers tested on this dataset 1
Each opens the paper’s page, with every claim, its outcome and the notebook that tested it.
Not yet verified2026-11-09
Open findings about the data 8
What the attempts that used this dataset found about the data themselves, for its owner and the archive, under the version of the dataset each was found on.
Dataset unversioned files (the archive keeps no versions) · tested 2026-11-09 · 8 open findings
- Data missingThe behavioural control data (three groups of 5, 9 and 15 listeners) behind Figure 2b and Supplementary Figures 1 and 5A are not in the data set, and the paper names no other place for them. Six of the paper's claims cannot be tested.#
Found by the attempt on Holdgraf et al. 2016 (holdgraf-2016-01, 2026-11-09) - Selection not documentedThe data set holds 416 channels (377 marked good) for its 7 subjects, at most 64 per subject, while the paper reports grids of 48, 64, 68, 68, 62, 110 and 104 channels and 468 electrodes kept. The data set does not say which channels were left out or why.#
Found by the attempt on Holdgraf et al. 2016 (holdgraf-2016-01, 2026-11-09) - Identifier missingThe subjects are named S01, S02, S03, S04, S07, S08 and S13, the paper's S1 to S7, with no mapping between them, so per-subject results cannot be compared with the paper's figures.#
Found by the attempt on Holdgraf et al. 2016 (holdgraf-2016-01, 2026-11-09) - Metadata errorchannels.tsv gives the unit as milliV and the header a resolution of 0.1, but the stored float32 values have a median absolute value of about 315 in S01 and 1.7e8 to 6.2e8 in the other six subjects, so the scale is neither millivolts nor the same across subjects.#
Found by the attempt on Holdgraf et al. 2016 (holdgraf-2016-01, 2026-11-09) - Metadata errorThe data set's explore_data notebook and its per-subject copies say the audio files are not available for privacy reasons, and the README says subject folders are named like ir-07; the zip holds a stimulus track per subject (stimuli/<subject>_audio.wav) and folders named sub-S01. The audio tracks are on the recording's clock (the mean audio amplitude rises 2.7 to 211 times at the event onsets in every subject), but S07's track is 1015 s for a 989 s recording, and S13's is at 20 kHz against 16 kHz in the others; neither is documented.#
Found by the attempt on Holdgraf et al. 2016 (holdgraf-2016-01, 2026-11-09) - Description missingThe events tables of S01, S03, S04 and S07 hold spans with trial_type 'bad' (1 to 12 per subject) that events.json does not describe, and 22 sounds overlap them; the paper does not mention them. They were kept here.#
Found by the attempt on Holdgraf et al. 2016 (holdgraf-2016-01, 2026-11-09) - OtherOne triplet in S02 and one in S03 lack a sound (46 of 47 and 38 of 39 complete), and S01 to S04 each have six unfiltered sentences outside any triplet (trial_num -1), which the data set does not explain.#
Found by the attempt on Holdgraf et al. 2016 (holdgraf-2016-01, 2026-11-09) - OtherThe stimulus tracks of S02, S04, S07 and S13 are not silent before the sound onsets: the auditory spectrogram from 0.45 s to the onset is 0.43 to 0.66 of that in the first 0.5 s of the sound, against 0.02 to 0.14 in S01, S03 and S08. The data set does not say whether the tracks hold background noise or other sound, which enters any model of the neural response on the audio.#
Found by the attempt on Holdgraf et al. 2016 (holdgraf-2016-01, 2026-11-09)
Badges for this dataset

It counts every claim tested on this dataset in a current attempt, verified or not, over every paper tested on it. To show it on the dataset’s own page, linked to this page:
<a href="https://encorescience.org/datasets/crcns/ac-4/"><img src="https://encorescience.org/badge/crcns/ac-4-outcomes.svg" alt="Encore: 10 reproduced, 2 partially reproduced, 7 not reproduced, 7 blocked, of 26 claims tested on CRCNS:ac-4"></a>
Or as Markdown:
[](https://encorescience.org/datasets/crcns/ac-4/)
The same numbers are in this page’s JSON, under
badge (how it is counted).