 "dataset": {
  "archive": "dandi",
  "id": "002034",
  "label": "DANDI:002034"
 },
 "page": "datasets/dandi/002034/",
 "generated": "2026-11-25T03:49:02+00:00",
 "caution": "A failure to reproduce is not a finding that the paper is wrong. It may be a failure of the attempt.",
 "outcome_counts": {
  "reproduced": 13,
  "partially_reproduced": 1,
  "not_reproduced": 2,
  "blocked": 0
 },
 "outcome_counts_with_outside_data": {
  "reproduced": 0,
  "partially_reproduced": 0,
  "not_reproduced": 0,
  "blocked": 0
 },
 "outcome_counts_elsewhere": {
  "reproduced": 0,
  "partially_reproduced": 0,
  "not_reproduced": 0,
  "blocked": 0
 },
 "outcome_counts_links": {
  "reproduced": 1,
  "partially_reproduced": 0,
  "not_reproduced": 0,
  "blocked": 0
 },
 "attempts": [
  {
   "id": "thompson-2026-01",
   "dataset": {
    "archive": "dandi",
    "id": "002034",
    "version": "0.261019.2146",
    "doi": "10.48324/dandi.002034/0.261019.2146",
    "relation": "primary"
   },
   "datasets": [
    "dandi:002034"
   ],
   "missing_datasets": [],
   "key": "dandi:002034",
   "label": "DANDI:002034",
   "dataset_version": "0.261019.2146",
   "paper": "10.7554/elife.112525",
   "paper_title": "Limitations of pupil diameter as a proxy for modes of locus coeruleus activity",
   "date": "2026-11-06",
   "kind": "agent",
   "accountable": "CatalystNeuro",
   "agent": {
    "harness": "Claude Code",
    "model": "claude-opus-5-5",
    "protocol": "pilot-13"
   },
   "runner": {
    "platform": "GitHub Actions",
    "url": "https://github.com/catalystneuro/encore/actions/runs/42192862980"
   },
   "outside": null,
   "tier": "agent_verified",
   "deprecated": "",
   "deprecated_on": null,
   "entry": "thompson-2026",
   "inputs": [
    {
     "what": "The include lists of sessions and units (Code/include_lists/manuscript_session_include.csv and manuscript_unit_include.csv), compared with the dandiset in the link claim; they hold exactly the dandiset's sessions and units, so no selection from outside enters the analysis.",
     "source": "https://github.com/lwthompson2/Thompson2026_LCPupilAnalysis at commit cf3c0b70ccf17188f9094f130aa39aa0487ba7a6"
    },
    {
     "what": "The code's printed statistics on this dandiset (Code/Results/manuscript_stats_nwb.txt), used only as reference values in the link claim.",
     "source": "https://github.com/lwthompson2/Thompson2026_LCPupilAnalysis at commit cf3c0b70ccf17188f9094f130aa39aa0487ba7a6"
    }
   ],
   "entry_title": "LC firing and pupil diameter, baseline and evoked (Thompson & Gold 2026)",
   "summary": "The paper's main findings held up in this data. Baseline LC firing and baseline pupil covary, as do evoked LC and evoked pupil responses, and each evoked response falls with its own baseline. Neither baseline reliably predicts the other signal's evoked response, per unit (Figure 2) and pooled (Figure 3), assuming as the paper's code does that the files' trial start marks fixation onset. Of the minor analyses, the raw-baseline control held in part, while a link between baseline LC and the range of evoked pupil in one monkey and a linear against quadratic fit comparison did not reproduce. Both appear only with the code's evoked pupil window and trial rule, which differ from the Methods.",
   "description": "Tests the findings of Thompson and Gold (2026) on dandiset 002034, which holds the 83 sessions of LC single units and pupil diameter from two monkeys in a passive fixation task with occasional beeps. It recomputes the within-epoch and cross-epoch correlations of Figure 2, the range analysis, the raw-baseline version of Supplemental Figure 1, the linear against quadratic fits of Supplemental Figure 2 and the pooled analysis of Figure 3, under the Methods' measures and under the paper's code.",
   "notebooks": [
    {
     "path": "reproduce_thompson_2026.ipynb",
     "title": "Reproducing Thompson & Gold (2026) from dandiset 002034",
     "cells": {
      "sanity": "6e5e2339",
      "claim:include-list-link": "8216c165",
      "claim:data-units-sessions": "aeeb8c52",
      "claim:fig2-row1-baseline-lc-pupil": "05628994",
      "claim:fig2-row2-evoked-lc-pupil": "05628994",
      "claim:fig2-row3-pupil-evoked-vs-baseline": "05628994",
      "claim:fig2-row4-lc-evoked-vs-baseline": "05628994",
      "claim:fig2-row5-baseline-lc-vs-evoked-pupil": "05628994",
      "claim:fig2-row6-baseline-pupil-vs-evoked-lc": "05628994",
      "claim:cross-epoch-no-reliable-relation": "08296cdd",
      "claim:range-baseline-pupil-evoked-lc": "b424a10d",
      "claim:range-baseline-lc-evoked-pupil": "f23da03f",
      "claim:figs1-raw-baselines-similar": "c600639f",
      "claim:figs2-llr-pupil-baseline-evoked": "a3615a78",
      "claim:figs2-llr-lc-baseline-evoked": "5d846b8c",
      "claim:figs2-llr-cross-epoch": "747732f6",
      "claim:fig3-pooled-within-epoch": "d4d54469",
      "claim:fig3-pooled-cross-epoch-null": "1ffb30f7"
     },
     "executed": "notebooks/thompson-2026/reproduce_thompson_2026.html"
    }
   ],
   "outcomes": [
    {
     "claim": "include-list-link",
     "statement": "The dandiset's sessions and units are those of the paper's code (its include lists), and the code's pipeline, run on the dandiset, gives the statistics the code printed for it.",
     "source": "Data availability; the code's Code/include_lists/*.csv and Code/Results/manuscript_stats_nwb.txt at commit cf3c0b7",
     "quote": "All data and analysis code necessary to generate figures is accessible at https://github.com/lwthompson2/Thompson2026_LCPupilAnalysis.git.",
     "statistics": [],
     "kind": "link",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:include-list-link",
     "notes": "All 83 sessions and 105 units on the code's include lists are in the dandiset and every dandiset unit is listed. The code's pipeline rewritten in Python and run on the dandiset matches 26 of 26 values the code printed (3974 beep and 15770 fixation trial rows, the twelve Figure 2 tests, the four range correlations, the eight LLR counts); the only visible difference is Ci row 1, p = 1.14e-5 against the printed 1.18e-5. The code's twelve printed Figure 3 pooled coefficients are matched to its three decimals (12 of 12) when firing rates are z-scored by within-session unit index across sessions, as zscore_tables.m does; z-scored per unit, 2 of 12 match.",
     "deviations": [
      "A link claim added by this attempt; it uses the code's printed output as reference values."
     ],
     "assumed": false,
     "disagreed": false,
     "data": "with_inputs",
     "where": null,
     "proposed": null
    },
    {
     "claim": "data-units-sessions",
     "statement": "The analysis used 42 LC single units from 32 sessions in monkey Oz and 63 units from 51 sessions in monkey Ci, recorded with pupil diameter during passive fixation with occasional startling beeps.",
     "source": "Results, paragraph 1",
     "quote": "N = 42 single units from 32 sessions in monkey Oz and 63 units from 51 sessions in monkey Ci",
     "statistics": [],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:data-units-sessions",
     "notes": "Oz 42 units in 32 sessions, Ci 63 units in 51 sessions, each with beep trials, spikes and pupil, under the Methods' and the code's trial rules (7 to 109 beep trials per unit under the Methods' rule, 7 to 111 under the code's). The code's second removal of two units gives 61 units in 50 sessions for Ci, the counts its printed output shows.",
     "deviations": [
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "fig2-row1-baseline-lc-pupil",
     "statement": "Trial-by-trial baseline LC firing rate is positively correlated with baseline pupil diameter within sessions, after correcting both for linear drift, in both monkeys.",
     "source": "Results, paragraph 2; Figure 2, row 1",
     "quote": "trial-by-trial measurements of baseline LC activity were positively correlated with simultaneously recorded measurements of baseline pupil diameter over the course of a session",
     "statistics": [
      {
       "about": "monkey Oz",
       "test": "Wilcoxon rank-sum test for H0, median partial Spearman correlation coefficient = 0",
       "p": 0.00086,
       "n": "42 units"
      },
      {
       "about": "monkey Ci",
       "test": "Wilcoxon rank-sum test for H0, median partial Spearman correlation coefficient = 0",
       "p": 9.85e-06,
       "n": "63 units"
      }
     ],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:fig2-row1-baseline-lc-pupil",
     "notes": "Median partial Spearman coefficient Oz 0.080 (T1 p = 5.5e-4, paper 8.6e-4), Ci 0.093 (p = 1.4e-5, paper 9.85e-6); 12 and 17 units significantly positive, 3 and 4 negative. The code reading gives p = 5.2e-4 and 1.1e-5; T2 and the code's removal of two units also give p < 0.001.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "fig2-row2-evoked-lc-pupil",
     "statement": "Baseline-subtracted evoked LC responses are positively correlated with baseline-subtracted evoked pupil responses within units, in both monkeys.",
     "source": "Results, paragraph 2; Figure 2, row 2",
     "quote": "Likewise, baseline-subtracted evoked LC responses were positively correlated with baseline-subtracted evoked pupil responses (p = 0.0135 for monkey Oz, p = 0.0018 for monkey Ci)",
     "statistics": [
      {
       "about": "monkey Oz",
       "test": "Wilcoxon rank-sum test for H0, median Spearman correlation coefficient = 0",
       "p": 0.0135,
       "n": "42 units"
      },
      {
       "about": "monkey Ci",
       "test": "Wilcoxon rank-sum test for H0, median Spearman correlation coefficient = 0",
       "p": 0.0018,
       "n": "63 units"
      }
     ],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:fig2-row2-evoked-lc-pupil",
     "notes": "Median above zero and T1 p < 0.05 in both monkeys under E1 (Oz 0.118, p = 0.011; Ci 0.024, p = 0.0028) and E2 (Oz 0.092, p = 0.020; Ci 0.053, p = 0.0026); paper 0.0135 and 0.0018. Code reading p = 0.0135 and 0.0015. Under T2 with E2, Oz gives p = 0.13 (variant).",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "fig2-row3-pupil-evoked-vs-baseline",
     "statement": "Baseline-subtracted evoked pupil responses are negatively correlated with baseline pupil diameter (drift residuals) within sessions, in both monkeys.",
     "source": "Results, paragraph 3; Figure 2, row 3",
     "quote": "baseline-subtracted evoked pupil responses were negatively correlated with baseline pupil diameter (using residuals; p = 1.16\u00d710-6 for monkey Oz, p = 5.02\u00d710-9 for monkey Ci; Figure 2, row 3)",
     "statistics": [
      {
       "about": "monkey Oz",
       "test": "Wilcoxon test for H0, median Spearman correlation coefficient = 0",
       "p": 1.16e-06,
       "n": "32 sessions"
      },
      {
       "about": "monkey Ci",
       "test": "Wilcoxon test for H0, median Spearman correlation coefficient = 0",
       "p": 5.02e-09,
       "n": "51 sessions"
      }
     ],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:fig2-row3-pupil-evoked-vs-baseline",
     "notes": "Median per-session coefficient negative and T1 p < 1e-5 in both monkeys under E1 (Oz -0.33, p = 7.9e-6; Ci -0.45, p = 2.0e-9) and E2 (Oz -0.37, p = 1.1e-6; Ci -0.37, p = 5.2e-9), over 32 and 51 sessions; the same with the code's 50 Ci sessions. Paper 1.16e-6 and 5.02e-9.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "fig2-row4-lc-evoked-vs-baseline",
     "statement": "Baseline-subtracted evoked LC responses are negatively correlated with baseline LC activity (drift residuals) within units, in both monkeys.",
     "source": "Results, paragraph 3; Figure 2, row 4",
     "quote": "Similarly, baseline-subtracted evoked LC responses were negatively correlated with baseline LC activity (using residuals; p = 5.88\u00d710-7 for monkey Oz, p = 1.04\u00d710-11 for monkey Ci; Figure 2, row 4)",
     "statistics": [
      {
       "about": "monkey Oz",
       "test": "Wilcoxon test for H0, median Spearman correlation coefficient = 0",
       "p": 5.88e-07,
       "n": "42 units"
      },
      {
       "about": "monkey Ci",
       "test": "Wilcoxon test for H0, median Spearman correlation coefficient = 0",
       "p": 1.04e-11,
       "n": "63 units"
      }
     ],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:fig2-row4-lc-evoked-vs-baseline",
     "notes": "Median negative in both monkeys (Oz -0.38, T1 p = 1.2e-6; Ci -0.30, p = 1.5e-11; paper 5.88e-7 and 1.04e-11), under every reading.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "fig2-row5-baseline-lc-vs-evoked-pupil",
     "statement": "Evoked pupil responses are not reliably related to baseline LC activity; the median per-unit correlation does not differ from zero in either monkey.",
     "source": "Results, paragraph 4; Figure 2, row 5",
     "quote": "evoked pupil responses were rarely positively or negatively related to baseline LC activity in a reliable manner (Wilcoxon rank-sum test for H0... p = 0.894 for monkey Oz, p = 0.904 for monkey Ci)",
     "statistics": [
      {
       "about": "monkey Oz",
       "test": "Wilcoxon rank-sum test for H0, median Spearman correlation coefficient = 0",
       "p": 0.894,
       "n": "42 units"
      },
      {
       "about": "monkey Ci",
       "test": "Wilcoxon rank-sum test for H0, median Spearman correlation coefficient = 0",
       "p": 0.904,
       "n": "63 units"
      }
     ],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:fig2-row5-baseline-lc-vs-evoked-pupil",
     "notes": "T1 p >= 0.05 in both monkeys under E1 (Oz p = 0.80, median 0.007; Ci p = 0.94, median 0.010) and E2 (Oz p = 0.99, median 0.023; Ci p = 0.95, median 0.012); paper 0.894 and 0.904. T2, the code's evoked pupil and the code's removal all give p >= 0.18.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "fig2-row6-baseline-pupil-vs-evoked-lc",
     "statement": "Baseline pupil diameter is not reliably related to evoked LC responses across monkeys; the median per-unit correlation does not differ from zero in Oz (p = 0.915) and does in Ci (p = 0.008).",
     "source": "Results, paragraph 4; Figure 2, row 6",
     "quote": "Likewise, baseline pupil diameter was rarely positively or negatively related to evoked LC responses reliably across monkeys (Figure 2, bottom row) (p = 0.915 for monkey Oz, p = 0.008 for monkey Ci)",
     "statistics": [
      {
       "about": "monkey Oz",
       "test": "Wilcoxon rank-sum test for H0, median Spearman correlation coefficient = 0",
       "p": 0.915,
       "n": "42 units"
      },
      {
       "about": "monkey Ci",
       "test": "Wilcoxon rank-sum test for H0, median Spearman correlation coefficient = 0",
       "p": 0.008,
       "n": "63 units"
      }
     ],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:fig2-row6-baseline-pupil-vs-evoked-lc",
     "notes": "Oz T1 p = 0.97 (median 0.036), Ci p = 0.034 (median -0.022), the paper's pattern (0.915 and 0.008). Code reading 0.915 and 0.0105. The Ci result is fragile. With the code's removal of two Ci units (a variant) Ci gives p = 0.064 under the Methods' trials and 0.019 under the code reading, so the outcome rests on the paper's 63 units, which the claims file takes. Leaving out beep trials whose 200 ms evoked window runs past the end of the trial (variant) gives Ci p = 0.029 with 63 units and 0.046 with 61. The code reading's 0.0105 rests in part on 85 beep rows its trial rule keeps and the Methods' rule drops, whose beep falls 7 to 69 ms before the end of the trial, so that most of the 200 ms evoked window lies past the end, where spikes are mostly not stored; their mean raw evoked rate is lower (Ci 3.15 against 6.99 sp/s). Without the beep trials whose 200 ms window runs past the end, the code reading gives Ci p = 0.028 (figs1 section).",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "cross-epoch-no-reliable-relation",
     "statement": "Despite consistent within-epoch relationships between LC activity and pupil size, there are no reliable relationships between the two across epochs (baseline of one against evoked of the other).",
     "source": "Results, paragraph 4, last sentence; Discussion, paragraph 3",
     "quote": "Thus, despite consistent relationships between LC activity and pupil size within each epoch, there were no reliable relationships between the two when comparing across epochs",
     "statistics": [],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:cross-epoch-no-reliable-relation",
     "notes": "Rows 1 and 2 hold in both monkeys, and neither row 5 nor row 6 is significant with one sign in both monkeys, under E1, E2 and the code reading.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "range-baseline-pupil-evoked-lc",
     "statement": "The correlation between baseline pupil and evoked LC responses does not depend on the range of evoked LC responses in either monkey.",
     "source": "Results, paragraph 5 (first additional analysis)",
     "quote": "We found that the relationship between baseline pupil diameter and evoked LC responses was not systematically impacted by the range of evoked LC responses for either monkey (Spearman\u2019s rho = 0.02, p = 0.89 for monkey Oz; rho = 0.07, p = 0.589 for monkey Ci)",
     "statistics": [
      {
       "about": "monkey Oz",
       "test": "Spearman correlation",
       "statistic": "rho = 0.02",
       "p": 0.89,
       "n": "42 units"
      },
      {
       "about": "monkey Ci",
       "test": "Spearman correlation",
       "statistic": "rho = 0.07",
       "p": 0.589,
       "n": "63 units"
      }
     ],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:range-baseline-pupil-evoked-lc",
     "notes": "Spearman of the row 6 coefficient with the range of evoked rates, Oz rho = 0.04, p = 0.78; Ci rho = 0.07, p = 0.60 (paper 0.02, 0.89 and 0.07, 0.589). Code reading 0.02, p = 0.89 and 0.05, p = 0.69.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The range is per unit, as in the code (claims file).",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "range-baseline-lc-evoked-pupil",
     "statement": "The correlation between baseline LC activity and evoked pupil responses does not depend on the range of evoked pupil responses in Ci (rho = 0.18, p = 0.16), but in Oz it becomes more negative as that range grows (rho = -0.33, p = 0.03).",
     "source": "Results, paragraph 5 (first additional analysis)",
     "quote": "the relationship between baseline LC activity and evoked pupil responses was not systematically impacted by the range of evoked pupil responses for monkey Ci (rho = 0.18, p = 0.16). However, we did observe a modest impact for monkey Oz (rho = -0.33, p = 0.03)",
     "statistics": [
      {
       "about": "monkey Ci",
       "test": "Spearman correlation",
       "statistic": "rho = 0.18",
       "p": 0.16,
       "n": "63 units"
      },
      {
       "about": "monkey Oz",
       "test": "Spearman correlation",
       "statistic": "rho = -0.33",
       "p": 0.03,
       "n": "42 units"
      }
     ],
     "kind": "finding",
     "inferred": "",
     "outcome": "not_reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:range-baseline-lc-evoked-pupil",
     "notes": "Ci gives p >= 0.05 under E1 and E2 (rho = 0.01, p = 0.92; rho = 0.10, p = 0.42), but Oz shows no correlation (E1 rho = -0.04, p = 0.80; E2 rho = -0.13, p = 0.40) against the paper's -0.33, p = 0.03. The code reading gives the paper's values (Oz rho = -0.33, p = 0.032; Ci 0.18, p = 0.16); neither mixture does (code trials with E1, Oz rho = -0.12, p = 0.45; Methods trials with the code's evoked pupil, rho = -0.20, p = 0.21). The range is a maximum minus a minimum, so it is set by extreme trials, and the code's trial rule keeps trials the Methods' rule drops (beeps near or after the end of the trial). The question of which window and trials the paper used is for its authors (findings). Leaving out beep trials whose 200 ms evoked window runs past the end of the trial (variant) gives Oz rho = 0.01, p = 0.94 (E1) and -0.10, p = 0.52 (E2).",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "figs1-raw-baselines-similar",
     "statement": "Using raw baseline measures in place of drift residuals gives results similar to those of Figure 2.",
     "source": "Results, paragraph 6 (second additional analysis); Supplemental Figure 1",
     "quote": "we obtained similar results when using raw baseline measurements as opposed to residuals (see Supplemental Figure 1)",
     "statistics": [],
     "kind": "finding",
     "inferred": "",
     "outcome": "partially_reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:figs1-raw-baselines-similar",
     "notes": "With raw baselines 11 of 12 row and monkey cells match the Figure 2 pattern under E1 and under E2 (T1); the cell that differs is row 6 in Ci (median -0.006, p = 0.14). The code reading matches all 12. Under T2, E2 matches 10. Leaving out beep trials whose 200 ms evoked window runs past the end of the trial (variant) also gives 11 of 12, with the same cell differing (p = 0.13). Row 6 does not use the evoked pupil, and it fails under both mixtures (code trials with E1, p = 0.131; Methods trials with the code's evoked pupil, p = 0.136), so the code's 12 of 12 comes from its trial set, not its pupil window. The code's rule keeps 85 beep rows (20 Oz, 65 Ci) that the Methods' rule drops; on each the beep falls 7 to 69 ms before the end of the trial, so most of the 200 ms evoked window lies past the end, where spikes are mostly not stored, and their mean raw evoked rate is lower (Ci 3.15 against 6.99 sp/s, Oz 4.75 against 5.96). The code reading without beep trials whose 200 ms window runs past the end gives row 6 Ci with raw baselines median -0.018, p = 0.12, not significant, so the code's match on this cell (p = 0.023) rests on evoked rates that are likely biased low. Code-rule trials whose beep falls after the end of the trial enter no table, since they have no evoked pupil.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "figs2-llr-pupil-baseline-evoked",
     "statement": "The relationship between baseline and evoked pupil responses is better described by a quadratic than a linear fit in only a minority of sessions (7 of 32 for Oz, 6 of 51 for Ci).",
     "source": "Results, paragraph 7 (third additional analysis); Supplemental Figure 2, first panel",
     "quote": "The relationship between baseline and evoked pupil responses was better described by a non-linear fit for a minority of sessions (LLR > critical value of 3.841... 7/32 sessions for monkey Oz, 6/51 sessions for monkey Ci)",
     "statistics": [],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:figs2-llr-pupil-baseline-evoked",
     "notes": "Under E1 with the paper's sessions, 6 of 32 Oz sessions and 7 of 51 Ci sessions have LLR above 3.841, both within one of 7 and 6 and under half. Under E2, 5/32 (outside the tolerance) and 5/51. The code reading gives 7/32 and 6/51 (6/50 with its removal). No session lacked enough trials to fit. The counts depend on the trial set. Leaving out beep trials whose 200 ms evoked rate window runs past the end of the trial, a variant aimed at the evoked rate, which this comparison does not use, gives 3/32 and 9/51 under E1 and 2/32 and 5/51 under E2.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Fits by ordinary least squares with Gaussian maximum likelihood, equal to fitlme without random effects fit by ML (the code).",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "figs2-llr-lc-baseline-evoked",
     "statement": "LC evoked responses are rarely better described by a quadratic than a linear function of baseline LC activity (2 of 42 units for Oz, 3 of 63 for Ci).",
     "source": "Results, paragraph 7; Supplemental Figure 2, second panel",
     "quote": "LC neuronal responses were rarely better characterized using a non-linear fit (2/42 neurons for monkey Oz, 3/63 for monkey Ci)",
     "statistics": [],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:figs2-llr-lc-baseline-evoked",
     "notes": "3 of 42 Oz units and 4 of 63 Ci units (4 of 61 with the code's removal) have LLR above 3.841, each within one of the paper's 2 and 3. The code reading gives 2/42 and 3/63.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "figs2-llr-cross-epoch",
     "statement": "Across-epoch relationships are rarely better described by a quadratic than a linear fit (baseline LC against evoked pupil, 4 of 42 units for Oz and 4 of 63 for Ci; baseline pupil against evoked LC, 2 of 42 and 5 of 63), so the null cross-epoch findings are not due to a non-linear relationship.",
     "source": "Results, paragraph 7; Supplemental Figure 2, third and fourth panels",
     "quote": "across-epoch comparisons showed similar trends that favored a linear relationship (baseline LC versus evoked pupil... 4/42 for monkey Oz, 4/63 for monkey Ci; baseline pupil versus evoked LC... 2/42 for monkey Oz, 5/63 for monkey Ci)",
     "statistics": [],
     "kind": "finding",
     "inferred": "",
     "outcome": "not_reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:figs2-llr-cross-epoch",
     "notes": "Evoked pupil on baseline LC, 5/42 (Oz) and 6/63 (Ci) under E1, 6/42 and 7/63 under E2, against 4/42 and 4/63; evoked LC on baseline pupil, 2/42 and 6/63 under both, against 2/42 and 5/63. No reading the criterion names has all four within one, and Oz's 5/42 and 6/42 are above a tenth of the units, so the partial rule does not apply. The code reading gives exactly 4/42, 4/63, 2/42 and 5/63. The counts stay small, so the statement that a linear fit is favoured holds; the claim's counts do not under the Methods' evoked pupil. The counts lie close to the cutoff. Under E1 a cutoff one higher would give 4/42 and 3/63 for evoked pupil on baseline LC, and one lower 9/42 and 9/63. Leaving out beep trials whose 200 ms evoked window runs past the end of the trial (variant) gives 6/42 and 5/63 under E1 and 8/42 and 7/63 under E2, the same outcome. The partial rule's bound of a tenth of the units is strict next to the 5% false positive rate of the cutoff (2.1 of 42 and 3.2 of 63 expected by chance); it is the claims file's and is applied as written.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "fig3-pooled-within-epoch",
     "statement": "With data z-scored per session or unit and pooled across trials, sessions and units for each monkey, the within-epoch relationships of Figure 2 hold (baseline LC with baseline pupil and evoked LC with evoked pupil positive; evoked against baseline negative for pupil and for LC).",
     "source": "Results, paragraph 8 (fourth additional analysis); Figure 3, columns 1 to 4",
     "quote": "we applied our single-unit analyses (Figure 2) to data pooled across all trials, sessions, and units (Figure 3). The results are qualitatively similar for the pooled and single-unit analyses",
     "statistics": [],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:fig3-pooled-within-epoch",
     "notes": "All four within-epoch columns give p < 0.05 in the sign of the Figure 2 row in both monkeys under E1 and E2 (8 of 8 cells), for example column 1 Oz rho = 0.090, Ci 0.063; column 3 Oz -0.38, Ci -0.39 under E1; also under every variant and the code's z-scoring. With raw baselines (variant) column 1 is not significant in Ci (rho = 0.005, p = 0.6). Pupil z-scored again per session (variant) and the variant without beep trials whose 200 ms evoked window runs past the end of the trial also give 8 of 8.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Firing rates are z-scored per unit (the Figure 3 legend and the claims file); the code groups by within-session unit index, shown as a variant.",
      "Assumption. Pupil is used as stored, taken as already z-scored per session (Methods, Pupillometry); the data check is consistent with this but the files do not say so, and the pooled coefficients mix sessions, so they rest on it. Pupil z-scored again per session (variant) changes them by at most 0.008. Asked of the paper's authors (findings).",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    },
    {
     "claim": "fig3-pooled-cross-epoch-null",
     "statement": "In the pooled data, neither baseline pupil against evoked LC nor baseline LC against evoked pupil shows a reliable relationship across monkeys, also when units are split by the sign of their significant baseline LC-pupil relationship.",
     "source": "Results, paragraph 8; Figure 3, columns 5 and 6",
     "quote": "in neither case showing a reliable relationship between baseline pupil and evoked LC responses or baseline LC activity and evoked pupil responses across monkeys. This result also held when LC units were separated based on the direction of their baseline relationship with pupil size",
     "statistics": [],
     "kind": "finding",
     "inferred": "",
     "outcome": "reproduced",
     "blocked_by": null,
     "notebook": "reproduce_thompson_2026.ipynb",
     "output": "claim:fig3-pooled-cross-epoch-null",
     "notes": "No cross-epoch column is significant with one sign in both monkeys, in all units or in either group, under any reading (0 of 60 cells). All units, column 6 Oz rho = -0.014, p = 0.62, Ci -0.019, p = 0.32 (E1). Ci's negative group (4 units) shows evoked LC falling with baseline pupil (rho = -0.17, p = 0.012), not seen in Oz's 3 units (p = 0.91). Neither unit the code removes as rows 43 and 65 is in a row 1 group under any reading (row 1 p = 0.15 to 0.42), so groups formed after the code's removal are the same and give the same result (0 cells significant with one sign in both monkeys), as does pupil z-scored again per session.",
     "deviations": [
      "Beep trials follow the Methods' rule (at least 100 ms of baseline, Methods, Pupillometry and Neuronal Recordings) and need one evoked pupil window before 20 ms from the end of fixation (implied by the Methods' window, stated here); fixation-only baseline rates end 20 ms before the end of the trial (Methods, Neuronal Recordings). The code's rule (beep more than 400 ms after the start and 800 ms before the end of the padded pupil record) and windows are a variant.",
      "The evoked pupil is read as the Methods describe it (50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation), as E1 and E2 (claims file); the code measures it over 0 to 800 ms after the beep with a centred 50 ms moving mean, shown as a variant.",
      "Assumption. Pupil is used as stored, taken as already z-scored per session (Methods, Pupillometry); the data check is consistent with this but the files do not say so, and the pooled coefficients mix sessions, so they rest on it. Pupil z-scored again per session (variant) gives the same result. Asked of the paper's authors (findings).",
      "Groups are the units whose row 1 partial correlation has p < 0.05 (12 positive and 3 negative in Oz, 17 and 4 in Ci under the Methods' trials), taken from all units in place of the code's table after its removal of two units; neither removed unit is in a group under any reading (printed).",
      "Assumption. The trial start is taken as fixation onset for every window, as the paper's code does; the files hold no fixation marker and do not say what event the trial start marks, the beep falls a median 2.2 s after it against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it, so the start may precede fixation onset (data check). Asked of the paper's authors (findings)."
     ],
     "assumed": true,
     "disagreed": false,
     "data": "dataset",
     "where": null,
     "proposed": null
    }
   ],
   "findings": [
    {
     "kind": "metadata_insufficient",
     "statement": "The pupil series (acquisition pupil_value_channel4, unit a.u.) is not described beyond its source variable. Its values are consistent with the Methods' preprocessing having been applied before deposit (per session mean near 0 and SD 0.80 to 0.99, the mean trace across trials within 0.19 of 0, smooth at 1 ms), but the file does not say so. The trial table's trial_time_index has no unit (milliseconds by its range, 4 to 61 min per session), the files do not say what event the trial start marks, spike times are given against artificial trial anchors 100 s apart (spike_time_policy), and every trial is marked correct, so the files appear to hold correct trials only without saying so.",
     "found": null,
     "status": null,
     "n": 4,
     "severity": "minor",
     "changes_results": false,
     "checked": null,
     "about": "data",
     "datasets": []
    },
    {
     "kind": "other",
     "statement": "Beep times run from about 1.0 to 2.8 s after the trial start (5th to 95th percentile; 8.8% of Oz and 4.4% of Ci beeps fall within 1 to 1.5 s), against the Methods' beep after 1 to 1.5 s of fixation; 8 beeps fall before the trial start and 83 after its end. 26% of Oz and 7% of Ci fixation-only trials last under 1 s (shortest 206 ms), against the Methods' fixation of 1 to 5 s. About 39% of spikes are stored in the few seconds before a trial's start (median 0.8 s before it) and under 2% after its end, with the rate falling from 4.4 sp/s in the last 200 ms of a trial to 0.85 sp/s in the 200 ms after it, so on the beep trials with less than 200 ms between the beep and the end (75 of 914 Oz and 96 of 2161 Ci beep trials under the Methods' rule, more under the code's) the 0 to 200 ms evoked rate is counted partly over a period without stored spikes.",
     "found": null,
     "status": null,
     "n": 5,
     "severity": "major",
     "changes_results": false,
     "checked": null,
     "about": "data",
     "datasets": []
    },
    {
     "kind": "metadata_insufficient",
     "statement": "The session Cicero_022714_d18_402_FixnStim is named for stimulation, but no file has a stimulation marker column, so whether any of its trials carried microstimulation cannot be told; the code's rule for fixation-only trials (no beep and no stimulation marker) then keeps all of its non-beep trials.",
     "found": null,
     "status": null,
     "n": 6,
     "severity": "minor",
     "changes_results": false,
     "checked": null,
     "about": "data",
     "datasets": []
    }
   ],
   "reconciliation": null,
   "verifications": [
    {
     "date": "2026-11-06",
     "kind": "agent",
     "by": "Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook)",
     "reviewed": "The handover of the author-answers run (commit b5ae64132f), the executed notebook with the conclusions and summary removed, the helper module and the claims file, with the paper under paper/.",
     "agreed": 17,
     "of": 17,
     "disagreements": []
    },
    {
     "date": "2026-11-06",
     "kind": "agent",
     "by": "Independent agent run by CatalystNeuro (same harness, separate context, did not write the notebook)",
     "reviewed": "The full executed notebook of the author-revise-1 run (commit 96982cac93), with its conclusions and summary, the helper module, the claims file, the attempt record and the README, with the paper under paper/.",
     "agreed": 17,
     "of": 17,
     "disagreements": []
    }
   ],
   "paper_notes": [
    {
     "kind": "code_mismatch",
     "statement": "The code's include list already lacks units 43 and 65 of the legacy numbering (its unit_id runs 1 to 107 without them), and prepare_figure_analysis_tables.m (build_stats) then removes rows 43 and 65 of its own 105-row table again, which drops CiCM101019d unit 1 and Ci_LC_d14_6mm_SC_123107 unit 2. This is why the code's printed output has 61 Ci units and 50 Ci sessions for some analyses against the paper's 63 and 51.",
     "found": null,
     "status": null,
     "n": 1,
     "severity": null,
     "changes_results": false,
     "checked": null,
     "about": "paper",
     "datasets": []
    },
    {
     "kind": "code_mismatch",
     "statement": "zscore_tables.m z-scores firing rates per value of the within-session unit index (unit 1, 2 or 3) pooled across all sessions and both monkeys, not per unit as the Figure 3 legend says (z-scored separately for each session/unit). Run here this way, the code's pipeline gives all 12 of the code's printed Figure 3 pooled coefficients to their three decimals; z-scored per unit, 2 of 12. Per unit the conclusions are the same.",
     "found": null,
     "status": null,
     "n": 2,
     "severity": null,
     "changes_results": false,
     "checked": null,
     "about": "paper",
     "datasets": []
    },
    {
     "kind": "code_mismatch",
     "statement": "The code measures the evoked pupil over 0 to 800 ms after the beep with a centred 50 sample moving mean, where the Methods give 50 ms windows in 10 ms steps from the beep to 20 ms before the end of fixation; it keeps beep trials more than 400 ms after the trial start and 800 ms before the end of the NaN-padded pupil record, where the Methods ask for 100 ms of baseline, so it keeps trials whose beep falls near or after the end of the trial (those after the end have no evoked pupil and enter no table, but 85 beep rows with the beep 7 to 69 ms before the end do); and it counts fixation-only baseline spikes to the end of the trial, not 20 ms before it. Under the Methods' measures two claims do not reproduce (the Oz range effect of rho = -0.33 and the cross-epoch LLR counts) and a third only in part, while the code reproduces the paper's numbers. On those 85 rows most of the 200 ms evoked rate window lies past the end of the trial, where spikes are mostly not stored, so their evoked rates are likely biased low; without beep trials whose 200 ms window runs past the end, the code reading no longer reproduces row 6 in Ci with raw baselines (p = 0.12, Supplemental Figure 1). Question for the authors: which window and trial rule produced the reported numbers?",
     "found": null,
     "status": null,
     "n": 3,
     "severity": null,
     "changes_results": false,
     "checked": null,
     "about": "paper",
     "datasets": []
    },
    {
     "kind": "paper_inconsistency",
     "statement": "The Results name a Wilcoxon rank-sum test for the one-sample hypothesis that the median coefficient is 0; the code runs the signed-rank test (signrank), whose p-values equal the printed ones. The Results also relate the coefficients to the range in each session, while the code takes the range per unit.",
     "found": null,
     "status": null,
     "n": 7,
     "severity": null,
     "changes_results": false,
     "checked": null,
     "about": "paper",
     "datasets": []
    },
    {
     "kind": "methods_unavailable",
     "statement": "Three choices that the outcomes here rest on are assumptions, asked of the paper's authors. First, which event does the trial start in the files mark? Every window is taken from it as fixation onset, as the code does, but the files hold no fixation marker, the beep falls a median 2.2 s after the start against the Methods' 1 to 1.5 s of fixation, and 39% of spikes are stored before it. Second, is the stored pupil trace already z-scored per session, with the mean trace subtracted and smoothed, as the Methods describe? The values are consistent with it, and the pooled Figure 3 coefficients rest on it. Third, which units and sessions did the paper use: its 63 units in 51 Ci sessions, or the 61 in 50 of the code's output? Row 6 in Ci is fragile on this point.",
     "found": null,
     "status": null,
     "n": 8,
     "severity": null,
     "changes_results": false,
     "checked": null,
     "about": "paper",
     "datasets": []
    }
   ]
  }
 ],
 "entries": [
  {
   "name": "thompson-2026",
   "type": "reproduction",
   "title": "LC firing and pupil diameter, baseline and evoked (Thompson & Gold 2026)",
   "description": "Tests the findings of Thompson and Gold (2026) on dandiset 002034, which holds the 83 sessions of LC single units and pupil diameter from two monkeys in a passive fixation task with occasional beeps. It recomputes the within-epoch and cross-epoch correlations of Figure 2, the range analysis, the raw-baseline version of Supplemental Figure 1, the linear against quadratic fits of Supplemental Figure 2 and the pooled analysis of Figure 3, under the Methods' measures and under the paper's code.",
   "datasets": [
    "dandi:002034"
   ],
   "papers": [
    "10.7554/elife.112525"
   ],
   "derived_from": [],
   "notebooks": [
    {
     "path": "reproduce_thompson_2026.ipynb",
     "title": "Reproducing Thompson & Gold (2026) from dandiset 002034",
     "cells": {
      "sanity": "6e5e2339",
      "claim:include-list-link": "8216c165",
      "claim:data-units-sessions": "aeeb8c52",
      "claim:fig2-row1-baseline-lc-pupil": "05628994",
      "claim:fig2-row2-evoked-lc-pupil": "05628994",
      "claim:fig2-row3-pupil-evoked-vs-baseline": "05628994",
      "claim:fig2-row4-lc-evoked-vs-baseline": "05628994",
      "claim:fig2-row5-baseline-lc-vs-evoked-pupil": "05628994",
      "claim:fig2-row6-baseline-pupil-vs-evoked-lc": "05628994",
      "claim:cross-epoch-no-reliable-relation": "08296cdd",
      "claim:range-baseline-pupil-evoked-lc": "b424a10d",
      "claim:range-baseline-lc-evoked-pupil": "f23da03f",
      "claim:figs1-raw-baselines-similar": "c600639f",
      "claim:figs2-llr-pupil-baseline-evoked": "a3615a78",
      "claim:figs2-llr-lc-baseline-evoked": "5d846b8c",
      "claim:figs2-llr-cross-epoch": "747732f6",
      "claim:fig3-pooled-within-epoch": "d4d54469",
      "claim:fig3-pooled-cross-epoch-null": "1ffb30f7"
     },
     "executed": "notebooks/thompson-2026/reproduce_thompson_2026.html"
    }
   ],
   "python": "3.13",
   "pinned": 20,
   "hashed": false
  }
 ],
 "badge": {
  "text": "13 findings reproduced",
  "reproduced": 13,
  "papers": [
   {
    "doi": "10.7554/elife.112525",
    "key": "thompson-2026",
    "byline": "Thompson et al. 2026",
    "title": "Limitations of pupil diameter as a proxy for modes of locus coeruleus activity",
    "relation": "primary",
    "reproduced": 13,
    "url": "https://encorescience.org/papers/thompson-2026/"
   }
  ],
  "url": "https://encorescience.org/datasets/dandi/002034/",
  "svg": "https://encorescience.org/badge/dandi/002034.svg",
  "alt": "Encore: 13 findings reproduced, from DANDI:002034"
 },
 "badges": {
  "reproduced": "https://encorescience.org/badge/dandi/002034.svg",
  "outcomes": "https://encorescience.org/badge/dandi/002034-outcomes.svg",
  "card": "https://encorescience.org/badge/dandi/002034-card.svg"
 }
}